Study of Transient Stability Improvement of IEEE 9-Bus System by using SVC

Similar documents
Transient Stability Improvement of Long Transmission Line System by Using SVC

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 10, 2015 ISSN (online):

Modeling and Simulation of Static VAR Compensator Controller for Improvement of Voltage Level in Transmission Lines

Voltage Profile Improvement of Transmission Lines Using Static VAR Compensator

POWER FACTOR CORRECTION USING SVC WITH FUZZY LOGIC CONTROLLER

CHAPTER 4 FACTS CONTROLLERS FOR OPTIMIZATION OF POWER SYSTEM

Transient Stability Improvement in Transmission System Using SVC with fuzzy logic Control

Transient stability of 11-bus system using SVC and improvement of voltage profile in transmission line using series compensator

Simulation and Analysis of Static Var Compensator with Matlab

Final Report. Mini Project TET Group nr 7 - Project nr 4. Students: Hans Lavoll Halvorson, NTNU

Performance analysis of FACTS devices in steady state power flow

Static Var Compensator: Effect of Fuzzy Controller and Changing Membership Functions in its operation

The Study of Voltage Profile and Power Quality with SVC in Transmission System at Different Loads

Chapter 3 MODELING OF SHUNT FACTS DEVICES. The Shunt FACTS Devices are used for voltage control and

SVC & TCSC for Minmum Operational Cost Under Different Loading Condition

International Journal of Scientific & Engineering Research Volume 4, Issue 2, February ISSN

Transient stability improvement using svc and pss

Power Stability and Oscillation Damping Analysis of a Three Machine Nine Bus System

Artificial Neural Network Controller With Static VAR Compensator to Improve Transient Stability for A Grid Connected Distributed Generation System

MODELING AND SIMULATION OF SVC CONTROLLER FOR ENHANCEMENT OF POWER SYSTEM STABILITY

IJETST- Volume 01 Issue 09 Pages November ISSN

Analysis of Power System Stability by Using Optimally Located SVC and STATCOM

Main Components of a Static Var Compensator (SVC)

OPTIMAL LOCATION OF SVC USING BENEFIT FACTORS TO IMPROVE THE VOLTAGE PROFILE IN POWER SYSTEMS

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI EE-2401 POWER SYSTEM OPERATION AND CONTROL UNIT-III REACTIVE POWER VOLTAGE CONTROL

Voltage Stability assessment by SVC Device Via CPF

A Novel Approach to Small Signal Stability Enhancement using Fuzzy Thyristor Susceptance control of SVC using Lyapunov Stability

Journal of Applied Research and Technology ISSN: Centro de Ciencias Aplicadas y Desarrollo Tecnológico.

FACTS and HVDC for Grid Connection of Large Wind Farms

Haidar Samet, and Mohammad Amin Jarrahi School of Electrical and Computer Engineering Shiraz University Shiraz, Iran

Research Article Development of Inexpensive Static Var Compensator Using PIC

A Svc Light Based Technique for Power Quality Improvement for Grid Connected Wind Energy System

Power Quality Enhancement using Different FACTS Devices.

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 7, Issue 1, July 2017

Optimization of Reactive Power by Using SVC and TCSC Devices for Reducing Transmission Losses

Optimal Placement and Sizing of SVC for Improving Voltage Profile of Power System

LAB1 INTRODUCTION TO PSS/E EE461: POWER SYSTEMS COLORADO STATE UNIVERSITY

ABB static var compensator stabilizes Namibian grid voltage

Simulation of FACTS Devices as Reactive Power Compensators and Voltage Controllers in the Smart Grid

Original Contribution EFFECTS OF PARALLEL FACTS CONTROLLERS ON STAEDY STATE VOLTAGE STABILITY MARGIN M. A. Kamarposhti 1 *, H.

Distribution Static Var Compensators and Static Synchronous Compensators for Suppressing Voltage Fluctuation

Introduction to new ABB STATCOM portfolio Power Grid Integration FACTS

ELG4125: System Protection

SVC static var compensator

Requirements for Data for Power System Modeling and Analysis (MOD-032-1) Arizona Public Service Company

Telecommunication of Stabilizing Signals in Power Systems

Lessons Learned in Static VAR Compensator Protection

CHAPTER 4 INCREASE IN CRITICAL CLEARING TIME USING SVC AND STATCOM IN TNEB

A guide on PowerWorld Simulator ver. 12.0

Approval...6. Current Revision...7. Introduction... 8 About PJM Manuals... 8 About This Manual... 8 Using This Manual...9

Performance Analysis of Power Flow Control Through Statcom, SVC and UPFC

[Kashyap*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

10 th Annual University of Pittsburgh Electric Power Industry Conference

POWER FLOW ANALYSIS AND PROTECTION COORDINATION OF REAL TIME SYSTEM

Christian PAYERL, Poznan, 20 th May, 2009 ABB FACTS Grid connection of Wind Farms. ABB Group May 22, 2009 Slide 1

Enhancement Voltage Stability of the Iraqi Power Grid Using Shunt FACTs Devices

Implementing the protection and control of future DC Grids

Quantum Chargers Enhanced AC Line Transient Immunity

WECC Criterion MOD-(11 and 13)-WECC-CRT-1.1

Study on Power Transformer Inrush Current

SMUD Model Data Requirements & Reporting Procedures MOD VERSION 1.2

Real Time Digital Simulator Testing of an On Line Integrated Stability Control System

Capacitor Only SVC Voltage Control Algorithm

Micro physical simulation system of electric power systems

Intelligent Application of Flexible AC Transmission System Components in an Evolving Power Grid

Load Flow Analysis. I Objectives

Optimal Allocation of Distributed Generation (DGs) and Static VAR Compensator (SVC) in a power system using Revamp Voltage Stability Indicator

Optimal Reactive Power Dispatch Using Hybrid Loop-Genetic Based Algorithm

PMU BASED PSS AND SVC FUZZY CONTROLLER DESIGN FOR ANGULAR STABILITY ANALYSIS AHMED SHEIKH. B.Sc., University of Engineering & Technology, Taxila, 2012

Simulation and modeling of grid connected TSC/TSR system using MATLAB

AUAS SVC, PERFORMANCE VERIFICATION BY RTDS AND FIELD TESTS. S. Boshoff C. van Dyk L Becker M Halonen, S Rudin, J Lidholm Dr T Maguire

Application of overvoltage protection to the Peruvian Power System

System Studies for American Transmission Co. s Benson Lake SVC Project

Hybrid electromechanical-electromagnetic simulation to SVC controller based on ADPSS platform

SYMPATHETIC INRUSH PHENOMENA IN PARALLEL AND SERIES CONNECTED TRANSFORMERS USING PSCAD

Enhancing the Grid Compliance of Wind Farms by Means of Hybrid SVC

SVC STATIC VAR COMPENSATOR.

SIEMENS POWER SYSTEM SIMULATION FOR ENGINEERS (PSS/E) LAB2 INTRODUCTION TO SLIDER BINARY (*.sld) FILES

Analysis of Data Quality Issues in Wide Area Monitoring and Control Systems

Small Generator Interconnection System Impact Study Report. Completed For Q0047

Effective Management of Transformer Inrush during Restoration of a Typical Industrial Power System

CASE STUDY : Transient Stability Simulation Package

Reactive Power Control and Transmission Line Loss Reduction with Realization of FACT Controller

Fuzzy based Excitation system for Synchronous Generator

Alternative Improving the Quality of Sub-Voltage Transmission System using Static Var Compensator

POWER SYSTEM SECURITY CONCEPTS

SVC Light for rail traction The way to effective grid integration

FURNAS Strategy Regarding Real-Time Tests: A Practical Case Campos Static VAr Compensator

Modelling and Simulation of Static VAr Compensator (SVC) in Power System Studies by MATLAB

RELAY CO-ORDINATION IN A 11KV SUBSTATION USING ETAP

Mehr Spannungsqualität im Netz mit SVC PLUS. Improvement in Voltage Quality for Power Systems with SVC PLUS

SVC FOR MAINTAINING OF POWER QUALITY IN THE FEEDING GRID IN CONJUNCTION WITH AN ELECTRIC ARC FURNACE IN A STEEL PLANT

Reduction of Inrush current in Three Phase Power Transformers using SSSC Device

IMPROVING POWER SYSTEM RELIABILITY USING MULTIFUNCTION PROTECTIVE RELAYS

Modelling and Simulation of the SVC for Power System Flow Studies: Electrical Network in voltage drop

Level 2, 3 and 4 Interconnection Application for Certified, Inverter Based Generating Facilities Not Greater than 2MW

Grid Operations - Program 39

empowering power system engineers

Studies Overview and Data Requirements. Robert Pan

Voltage Control in Southwest Utah With the St. George Static Var System

Transcription:

Study of Transient Stability Improvement of IEEE 9-Bus System by using SVC Rathnasagar Rangu 1, Poonam Upadhyay 2 1 PG Student, VNR VJIET, Hyderabad, India 2 Professor, VNR VJIET, Hyderabad, India Abstract the objective of this paper is to determine the improvement in transient stability of IEEE 9Bus system using STATIC VAR compensator. SVC is one of the FACTS devices which can make the power supply more efficient and reliable. Power systems are continuously subjected to various types of disturbances which in turn cause the problem of losing stability. Transient stability is one of the most important stability of the power system. The loss of Transient stability is due to varies disturbances like faults, sudden change in loads and tripping off the lines after fault or heavy loss of loads. Power systems are Operating nearer to their stability limits due to economic and environment reasons. In under damped Power systems disturbances lead power system into unstable state. So, the tools for mitigating such a sensitive problem have an important significance. Static VAR Compensator (SVC) can control reactive power and therefore it is used to improve transient stability as well as the voltage profile. The proposed work includes IEEE 9-Bus Test system incorporated with SVC controller using Mipower Software. The simulation shows how the oscillations are damped out with SVC controller. Keywords- Power system modeling; Mipower software techniques; Simulations; Transient stability; SVC I. INTRODUCTION Transmission networks of present power systems are becoming progressively more stressed because of increasing demand and limitations on building new lines. One of the consequences of such a stressed system is the risk of losing stability following a disturbance. Flexible ac transmission system (FACTS) devices are found to be very efficient in a stressing transmission network for better utilization of its existing facilities without sacrificing the desired stability margin. Flexible AC Transmission System (FACTS) controllers, such as Static VAR Compensator (SVC) and Static Synchronous Compensator uses the latest technology of power electronic switching devices in electric power transmission systems to control voltage and power flow, and play an important role as a stability aid for and transient disturbances in an interconnected power systems. The electric power industry has experienced a huge increment in power consumption. The growth in demand for electricity supply such as growth of loads and generation, lack of new transmission lines and competitive electricity market pressure has made power systems nowadays operating closer to their static and dynamic limit. Despite of the fact that bulk power transfers are increasing, the growth of electric power transmission facilities is restricted. In addition with the aging of power transmission network, the control of power transmission is required to be fast and reliable. Power systems are also often subject to low frequency electro-mechanical oscillations resulting from electrical disturbances and consequence of the development of interconnection of large power system. The oscillation of the generators rotors cause the oscillation of other power system variables (bus voltage, transmission lines active and reactive power, etc) which constraints the capability of power transmission, threatens system security and damages the efficient operation of the power system. Low frequency oscillation can be categorized to as local and inter-area mode. Local mode oscillation typically range between 1-2 Hz consists of the oscillation of a single generator or a group of generators against the rest of the system, while interarea mode typically range between 0.1-1 Hz consists of the oscillation among groups of generators. Generally, power system stabilizers (PSS) are applied on selected generators to damp local oscillation modes effectively. The fast progress in the field of power electronics has widened the option for power industry to improve power system stability via utilization of the controllable flexible alternating current transmission system (FACTS). Besides their capability to control transmission grid and increasing transmission capacity, FACTS devices also offer an alternative option to mitigate power system oscillation. According to IEEE, FACTS device is a power-electronic based system and other static equipment that provide control of one or more ac-transmission system parameters to enhance controllability and increase power-transfer capability. Initially, FACTS device was developed to solve rising system problems due to the limit in ISSN: 2231-5381 http://www.ijettjournal.org Page 162

transmission line construction, to facilitate the increasing power export and/or import and wheeling transaction among utilities. FACTS devices have cover a number of technologies that enhance the security, capacity and flexibility of power transmission systems. By installing FACTS devices, the power systems will able to increase existing transmission network capacity while maintaining or improving the operating margins necessary for systems stability. As PSS been applied to damp local oscillation modes, Static VAR Compensator (SVC) which is one of the FACTS devices, has been used as a supplementary controller to improve transient stability and power oscillation damping of the system. Most of these controllers are designed based on conventional method i.e designed based on the literalized model for the sake of simplicity. However, conventional controller cannot provide satisfactory performance over a wide range of operation points and under large disturbances since power system is a non-linear system. The flexibility of present transmission systems needs to be dramatically increased under the thyristorbased transmission or FACTS Controllers, (the Static Var Compensator or SVC, the Thyristor- Controlled Series Capacitor or TCSC, and the Thyristor- Controlled Phase Angle Regulator or TCPAR) employ conventional thyristors (i.e., those having no intrinsic turn-off ability) to control one of the three parameters determining power transmission, voltage (SVC), transmission impedance (TCSC), and transmission angle (TCPAR). Shunt compensation can be achieved through the use of static VAR compensators, which is currently a mature technology. When discussing the creation, movement, and utilization of electrical power, it can be separated into three areas, which traditionally determined the way in which electric utility companies had been organized. These are illustrated in Figure 1 and are: Generation Transmission Distribution Fig.1. Illustration of the creation, movement, and utilization of electric power The power electronic based equipment is prevalent in each of these three areas, such as with static excitation systems for generators and Custom Power equipment in distribution systems. II. POWER SYSTEM STABILITY Stability: The stability of a system refers to the ability of a system to return back to its steady state when subjected to a disturbance. As mentioned before, power is generated by synchronous generators that operate in synchronism with the rest of the system. A generator is synchronized with a bus when both of them have same frequency, voltage and phase sequence. We can thus define the power system stability as the ability of the power system to return to steady state without losing synchronism. Usually power system stability is categorized into Steady State, Transient and Dynamic Stability shown in Figure 2. Fig.2. Classification of power system stability A. Steady State Stability: Studies are restricted to small and gradual changes in the system operating conditions. In this we basically concentrate on restricting the bus voltages close to their nominal values. We also ensure that phase angles between two buses are not too large and check for the overloading of the power equipment and transmission lines. These checks are usually done using power flow studies. B. Transient Stability: Involves the study of the power system following a major disturbance. Following a large disturbance the synchronous alternator the machine power (load) angle changes due to sudden acceleration of the rotor shaft. The objective of the transient stability study is to ascertain whether the load angle returns to a steady value following the clearance of the disturbance. C. Dynamic stability: The ability of a power system to maintain stability under continuous small disturbances is investigated under the name of Dynamic Stability (also known as small-signal stability). These small disturbances occur due random fluctuations in loads and generation levels. In an interconnected power system, these random variations ISSN: 2231-5381 http://www.ijettjournal.org Page 163

can lead catastrophic failure as this may force the rotor angle to increase steadily. III. STATIC VAR COMPENSATER Static Var systems are used in transmission applications for several purposes. The primary purpose is for rapid control of voltage at weak points in a net work. Installations may be at the midpoint of transmission interconnections or at the line ends. The Static Var Compensator is basically a shunt connected variable Var generator whose output is adjusted to exchange capacitive or inductive current to the system to control reactive Power and voltage of the electric power systems. One of the most widely used configurations of the SVC is the FC-TCR type in which a Fixed Capacitor (FC) is connected in parallel with Thyristor Controlled Reactor (TCR). In its simple form SVC is connected of FC-TCR configuration as shown in Figure.3. The SVC is connected to a coupling transformer that is connected directly to the ac bus whose voltage is to be regulated. Inductive Reactive Power Absorption (-Qind) Thyristor valves Step Down Transformer T 2 High Voltage Bus -Q ind +Q cap L T 1 TCR (Thyristor Controlled Reactor) Y Low Voltage Bus Q net = Q cap - Q ind FC Capacitive Reactive Power Injection (+Qcap) Relay C (Fixed capacitor) Fig.3 Typical SVC System The effective reactance of the FC-TCR is varied by firing angle control of the anti parallel thyristors. The firing angle can be controlled through a controller in such a way that the voltage bus where the SVC is connected is maintained at the reference value. The model of SVC is shown in Figure. The magnitude of the SVC is inductive admittance BL (α) is a function of the firing angle α and is [5] given as Vs Is SVC bus bar voltage and QL is MVA rating of reactor. As the SVC uses a fixed capacitor and variable reactor combination (TCR- FC), the effective shunt admittance is Where X C is capacitive reactance. IV. POWER OSCILLATION DAMPING In case of an under damped power system, any minor disturbance can cause the machine angle to oscillate around its steady sate value at the natural frequency of the total electromechanical system. The angle oscillation, of course, results in a corresponding power oscillation around the steady state power transmitted. The lack of sufficient damping in some cases may become a limiting factor for the transmittable power. Since the power oscillation damping is a sustained dynamic event, it is necessary to vary the applied shunt compensation. As the SVC can give variable VAR output, it can be controlled in such a way that it will give the capacitive or leading reactive power when the rotationally oscillating generator accelerates i.e. dδ/dt>0,so that the compensator increases the midpoint voltage hence the transmitted power. As the SVC is controlled to give lagging reactive power, when the rotationally oscillating generator decelerates i.e. dδ/dt<0 so that the electric power transmitted will be decreased to balance the insufficient mechanical power input. In this way the we can reduce the oscillations generated in the power system. So, By employing the SVC in the system we can reduce the oscillations of power angel When there is an occurrence of fault, by Controlling the thyristor switches which were connected to Inductor and Capacitor banks respectively we can do this. In the figure.4 shows the damping of Power Oscillations in two machine Power system. Power wave forms with respect to time without SVC and with SVC.The Power Oscillations are damped quickly by using SVC. ISSN: 2231-5381 http://www.ijettjournal.org Page 164

GENERATOR DATA TABLE FROM POWER Q-MIN Q- MAX V- SPEC CAP. MVA NAME* MW MVAr MVAr p.u. CURV RATING Bus1 71.6-72 72 1.04 0 247.5 Bus2 163-72 72 1.025 0 192 Bus3 85-72 72 1.025 0 128 LOAD DATA TABLE FROM REAL REACTIVE NAME* MW MVAr Bus8 50 15 Change in load here Bus5 125 50 Fig.4. Damping of Power Oscillations V. SIMULATION RESULTS Here IEEE 9Bus Test System is taken for the analysis of transient stability. MiPower simulation Software is used for performing the analysis. The single line diagram is shown in figure 5.The system analysis is carried with parameters on 100 MVA base. The SVC with Control block is modeled in Mipower with rating 22MVAR. Bus6 90 30 FROM BUS VOLTAGES AND POWERS DATA TABLE V- MAG ANGLE MW MVAr MW MVAr MVAr NO. NAME p.u. DEGREE GEN GEN LOAD LOAD COMP 1 Bus1 1.04 0 23.877 30.737 0 0 0 2 Bus2 1.025 14.27 163-2.941 0 0 0-3 Bus3 1.025 9.47 85 19.233 0 0 0 4 Bus4 1.0231-0.74 0 0 0 0 0 5 Bus5 0.9926-1.3 0 0 125 50 0 6 Bus6 1.0105-1.04 0 0 90 30 0 7 Bus7 1.0316 8.74 0 0 0 0 0 8 Bus8 1.0328 6.79 0 0 50 15 0 9 Bus9 1.0321 6.78 0 0 0 0 0 a. Test Case1: For Transient stability analysis the disturbance is given to the system by changing load C form 100MW and 35MVAR to 150 MW and 50MVAR at 0.1Sec.Waves of Voltage (pu) with respect to time by with and without connecting SVC is Plotted. Fig.5. IEEE 9 Bus Test System Three Generators are connected at the Bus No. 1, 2, 3 and loads are connected at the Bus No 5, 6, 7 as shown in the figure. The network data is presented in the given tables. Fig.6. Voltage (pu) Wave forms at Bus 8 with and without SVC b. Test Case 2: In this Case, the disturbance is given to the system by changing the load at ISSN: 2231-5381 http://www.ijettjournal.org Page 165

Bus 8 form 35MW and 15MVAR to 80MW and 50MVAR at 0.1Sec.Waveform of Voltage (pu) with respect to time by with and without connecting SVC is Plotted. transmission line Voltage and Power Oscillations are low when we connect SVC and transient period has decreased to a significant value for above parameters of transmission line. So, it can be concluded that the transient stability of IEEE 9bus test system with different loads is improved by using SVC. REFERENCES Fig.7. Voltage (pu) Waveforms at Bus 8 with and without SVC [1] Dr.Tarlochan Kaur and Sandeep Kakran, Transient Stability Improvement of Long Transmission Line System by Using SVC, International journal of Advanced Research in Electrical,Electronics and Instrumentaion Engineering,Volume No.1,October 2012. [2] N.G. Hingorani and L. Gyugyi, Understanding FACTS, IEEE Press, New York, USA, 1999 [3] Swaroop Kumar.Nallagalva, Mukesh Kumar Kirar and Dr.Ganga Agnihotri, Transient Stability Analysis of the IEEE 9-Bus Electric PowerSystem, International Journal of Scientific Engineering and Technology, Volume No.1, July 2012. [4] IEEE Power Engg. Society/CIGRE, FACTS Overview, Publication 95 TP 108, IEEE Press, New York, 1995. [5] Brien M.O,B.E, and Ledwich G Placement of Static Compensator for Stability improvement, IEEE 1985. [6] Ajay Chaudhary and Ram Avtar Jaswal, Transient Stability Improvement of Multi Machine Power System Using Static VAR compensator, International Journal of Electronic and Electrical Engineering, Volume 7, Number 2, 2014. [7] Alok Kumar and Surya Bhushan Dubey Enhancement of Transient Stability in Transmission Line Using SVC Facts Controller, International Journal of Recent Technology and Engineering, Volume-2, May 2013. [8] Ramlal Das and D. K. Tanti, Transient stability of 11-bus system using SVC and improvement of voltage profile in transmission line using series compensator, American Journal of Electrical Power and Energy Systems, 2014. [9] P. Kundur, Power System Stability and Control, McGraw- Hill, Inc., New York, 1994. [10] IEEE Power Engineering Society, FACTS Applications, Publication 96 TP 116-0, IEEE Press, New York, 1996. Fig.8 Reactive Power Waveforms at Bus 8 with and without SVC VI. OBSERVATIONS From the simulation work it is clear that the transient stability of the system is highly affected by SVC. The damping time is reduced from 9sec to 7sec in both the cases. Voltage Profile is improved, the amplitude of oscillations reduced from 8.5 KV to 2.2KV in case1 and 14.3KV to 4.4KV. So, With SVC In transmission line, Voltage and Power Oscillations are damped quickly and transient period has decreased. VII. CONCLUSION Improvement of Transient Stability of IEEE 9Bus Test System with SVC is observed by making a simulation model in Mipower. The usefulness of SVC to damp power Oscillations in multi machine Power system is studied. It is found that the transient stability of the Power system is highly affected by SVC. In ISSN: 2231-5381 http://www.ijettjournal.org Page 166