Pressure Switch CE0 NEW IR Communication type Pressure Switch Rev. Fluids/Gasses Utilizing Stainless Diaphragm Utilizes stainless steel diaphragm for use with a wide variety of pressure media Excellent environmental resistance (IP67) (IP65 for ranges 2MPa or below) Available in various measurements/settings /memory functions with ER0 IR COMMUNICATOR (IR data communication) Digital settings available via IR data communication without actually applying pressure to the unit CE0 Pressure Switch ER0 IR COMMUNICATOR (Indicator Setting Unit) *Anti-shock silicone case (Option)
Newly designed small and lightweight pressure switch is now available exploring new applications used in conjunction with dedicated terminal unit CE0 (Indicating Part) Comparator switch operation can be selected and set via IR data communication OUT: Output LED (Red) M2 Connector OUT2: Output LED (Red) Pressure Upper Limit on OUT off Lower Limit on OUT 2 off [Hysteresis Mode] When OUT is set as the upper limit and OUT2 as the lower limit. Upper Limit Point Dead band (Determined by positive number) Dead band (Determined by negative number) Lower Limit Point The Upper limit (dead band determined by positive number) and lower limit (dead band determined by negative number) of OUT and OUT2 can be adjusted to any points within full scale range. Setting Point(A) Lower Limit Point Selectable between OUT2 Setting Point(b) two switch operations Upper Limit on OUT off Lower Limit on OUT 2 off [Window Comparator Mode] When OUT is set as the upper limit and OUT2 as the lower limit. Pressure Setting Point(b) OUT Upper Limit Point Setting Point(A) The Upper limit (A<b) and lower limit (A>b) of OUT and OUT2 can be adjusted to any points within full scale range. Power LED (Blue or Green) IR detector/indicator* On/off delay can also be set for each setting point Power LED turns Red and Green for NPN/PNP identification Blue NPN on off ON delay OFF delay Green PNP *Communication range between CE0 and ER0 Effective range within 300mm Effective angle within ±30 Protection cap (Accessory) When the CE0s are adjacently mounted, the attached protective cap is effective shutting off other signals input to the IR receiver. It also helps for keeping IR detector/operation indicating part clean. OUT OUT2 ER0 (Indicating/Setting Part) IR Detector/Indicator (Main body side) IR Extension Cable (Optional) Cable attachment can establish one-to-one communication with CE0. A display message of ext at the upper left on LCD indicates that extension cable is attached. Connector for IR extension cable USB 2.0 micro-b (Female) IR detector/indicator Charge Lamp LCD IR extension cable (2m) Clip Power On/Off ext indication Cursor Keys (,,, ) Enter ( ) Mounted on CE0
Pressure Switch CE0 ER0 (Configurations and Functions) *Refer to instruction manual for operation procedure MEASURE MAIN MENU CONFIG Real-time pressure value indication [PRS] Setting Value Adjustment [SET] Zero Adjustment [ADJ] Peak Hold [TOP, BTM] Loop Check [LPC] MEASURE SETTING MEMORY CONFIG Ir: IR sensor element selectable SleepTime: Automatic power OFF BackLight: Brightness Contrast: Contrast Difference Read Setting Value from CE0 and Edit SETTING MEMORY Edit Setting Value Saved into CE0 COMPARATOR: Comparator setting DELAY (On, Off): (Hysteresis/Window comparator) ON/Off and delay time setting FUNCTION: NPN/PNP output selection Comparator Operation Selection: Hysteresis or Window comparator Filter function: It is useful when pressure fluctuations can result in erratic, difficult to read displays (Selectable 6 internal time constant filters: 0ms, 50ms, 50ms, 500ms, s, 5s) SPECIAL: Engineering Unit: Selectable Key Lock: It manually disables CE0 IR communication by selecting LOCK. CE0 program version is displayed. Display on Measurement Mode Transmission Status Comparator Output Operation Status Setting value /Deadband CE0 Serial number Battery life indicator Pressure Value Pressure Unit User can edit and send setting data in ER0. (COMPARATOR/DELAY/FUNCTION/SPECIAL etc.) FILE: Sets Tag No. of saved files. COPY: Saves setting data read from CE0 to ER0. SEND: Sends edited data to CE0. SEARCH: Starts a connection (pairing) with CE0. *Max. Memory Storage: 2 Comparator Setting Table Open collector output: Select NPN or PNP. Items Factory Default Setting Other than Default Settings Setting OUT: Upper limit (H) 50% F.S. or above On Value OUT2: Lower limit (L) 50% F.S. or below On Specify Deadband Hysteresis 0%F.S. preferable Delay 0s setting if any Filter No setting (Response time: ms or less) when ordering ER0 Memory Function User can save the data read from CE0 with IR communication and the data input from the PC to the ER0 Memory. USB cable Dedicated software is available from our website. Option: USB cable (m) *USB 2.0 micro-b (Male) -USB type A *USB cable (for charging/data transmission) is also available on the market.
CE0 Pressure Switch Specification Pressure Ranges Accuracy Temperature Characteristics (at 23 ) Zero Span 0 to 0.5MPa (500) 0. to 0.5MPa (600) 0 to MPa (000) 0. to MPa (00) Repeatability 0 to 2MPa (2000) 0. to 2MPa (200) ±0.2%F.S. 0 to 3.5MPa (3500) 0 to 5MPa (500) Setting Accuracy* ±0.05%F.S./ ±0.05%F.S./ 0 to 0MPa (000) ±(0.5%F.S. + count) 0 to 20MPa (2000) 0 to 35MPa (3500) 0 to 50MPa (500) ( ) represents count number Item Max. allowable pressure* 2 Media Operating condition Process Connection Power Supply 2X pressure range (35 and 50MPa:.5X) Description Air, water and oil compatible with wetted parts Install in location where no combustible gas or liquids exists that is liable to cause an explosion or fire in normal condition R/, G/A (0MPa or below), G3/8A 9 to 36V DC Setting Method IR Communication (Effective communication range within 300mm* 3 ) Current Consumption 30mA DC (max) not including comparator output current Display Comparator operation indicator Red LED 2 (When ON) Power Indicator NPN: Blue LED PNP: Green LED Output Comparator Outputs (Default) NPN open collector 2 outputs PNP open collector 2 outputs Actuation Delay Time Deadband Output Capacity* Response time 50ms Hysteresis Variable Window Comparator Fixed at %F.S. NPN 36V DC, 250mA (max) PNP Output Capacity, 250mA (max) ms or less Operating Temperature -20 to 70 Operating Humidity 85%RH or less when pressure range is 2Mpa or below (Non-Freezing, Non Condensing) Storage Temperature/Humidity -30 to 80, 95%RH or less (Non-Freezing, Non Condensing) Withstand Voltage Leak current 5mA (max) (250V AC (50/60Hz), minute) Insulation Voltage 00MΩ min. (50V DC) Case Construction Indoor use (IEC60529 IP67) (Ranges 2MPa or below: IEC60529 IP65) Case Material SUS30, PES Wetted Parts SUS630 (7-PH), SUS30, Rigid NBR (Depending upon connection size) Vibration Frequency 0 to 2000Hz, Acceleration 200m/S 2 Shock Acceleration 000m/s 2, Operating time: 6ms Connector M2 Connector (-pin) Protective Circuit Reverse-polarity protecting system, Short-circuit (over-current) protection Weight Approx. 00g Approvals UL/cUL (Pending), EMC, RoHS2 * Accuracy includes the effects of linearity and Hysteresis *2 Allowable maximum pressure is the upper limit of pressure value which may safely be applied to the product and remain in specification once pressure is returned to the rated pressure range with a couple of times overpressurization for about 0 minutes. Effects of continuous overpressure are not guaranteed. *3 Effective range for IR communication with ER0 (Sold Separately) * Output capacity vs. Temperature: 00mA max at 55 to 70, 50mA max at 5 to 55, 200mA max at 35 to 5, 250mA max at -20 to 35. Minimum residual voltage: Less than 2.V DC at 250mA, Less than.7v DC at 00mA ER0 IR COMMUNICATOR (Indicator Setting Unit) Specification Item Description Transmission Method IR Communication Communication Range Effective range within 300mm Effective angle within ±30 Batteries AAA battery 2 (Rechargeable nickel-hydrogen or Alkaline batteries) Charge (USB Connector) USB 2.0 micro-b (Female) Operating Temperature 0 to 0 (When Nickel hydrogen batteries is used.) Storage Temperature 0 to 50 (Batteries removed) Enclosure Structure Indore use (non-waterproof) Case Material ABS Option Anti-shock silicone case, IR extension cable Optional Anti-shock silicone case (Color: Dark gray) IR Extension Cable (2m)
Pressure Switch CE0 CE0 External Dimension Pressure Connection Input/output Connector Pin-out 2 3 Pin Number 2 3 *Above shows optional M2 mating connector. Output LED OUT Power LED φ30 Description Power (+), COM (When PNP open collector is selected) OUT2 Open collector output Power ( ), COM (When NPN open collector is selected) OUT Open collector output M2 Input/output connector Output LED OUT2 IR Detector/Indicator 6 Cable Color* Brown White Blue Black L type cable attachment For or less (φ8) φ9 G/A G3/8A 2 2 O-ring JIS B 20 B-P φ0.7 orifice throttle* Tightening Torque 27 Hex. 0 0 52 Vent hole For 2MPa or below only For or less (φ8) *Throttle (Option) (φ22) 6 O-ring JIS B 20 B-P φ0.7 orifice throttle* Tightening Torque R/ For or less (φ8) (φ22) ER0 External Dimension 6 φ0.7 orifice throttle (Option) Tightening Torque 6N m M2 mating connector cable (Optional) PUR cable Straight Type 2 3 L type 27. 3.5 2 3 Material Zinc alloy diecasting (nickel plating) 2 TPU 3 PUR Cable length (L) Conductor cross-sectional area Insulator outside diameter Sheath outside diameter 2m (Standard), 5m 0.3mm 2 (22AWG).27mm.7mm PVC cable Straight Type 2 3 35.2 2 3 L type Connector for IR extension cable USB 2.0 micro -B (Female) for PC communication and Charging IR Detector/Indicator Charge Lamp IR COMMUNICATOR LCD 5 27. 69 9.5 Material Stainless steel 2 TPU 3 PVC Cable length (L) Conductor cross-sectional area Insulator outside diameter Sheath outside diameter 2m (Standard), 5m 0.3mm 2 (22AWG).52mm 5.2mm
Model Number Configuration Please specify the model number, each specs and the range for ordering. Model Name C E 0 M IR Communication Type Pressure Switch Model Number Specification Additional Spec. Standard Specifications CE0 Protection class: Indoor use IP67 (2MPa or below: IP65) Transmission Method: IR Communication Effective range with ER0 IR COMMUNICATOR (Sold Separately): within 300mm Model M Integral connector type M2 P Pressure Connection 7 R/ Max. 50MPa B G/A Operating 0MPa C G3/8A Pressure 50MPa Wetted Parts Diaphragm: SUS630 (7-PH) Fitting: SUS30 Pressure Ranges No. Pressure Ranges MPa No. Pressure Ranges MPa 5 6 7 E G J 0. to 0.5 0. to.0 0. to 2.0 0 to 0.5 0 to 0 to 2 K L N Q R S 0 to 3.5 0 to 5 0 to 0 0 to 20 0 to 35 0 to 50 Power Supply W 9 to 36V DC Accuracy Repeatability: ±0.2%F.S. Setting Accuracy: ±(0.5%F.S.+ count) Accessory: Protection Cap (IR detector/indicator) Option (Sold Separately): M2 mating connector cable Types of M2 mating connector cable PUR Cable Straight Cable length 2m (Oil proof) L type Cable length 2m PVC Cable Straight Cable length 2m (Stainless steel nut) L type Cable length 2m PUR Cable Straight Cable length 5m (Oil proof) L type Cable length 5m PVC Cable Straight Cable length 5m (Stainless steel nut) L type Cable length 5m *Specify preferable comparator settings at the time of order over factory default setting (if any). Refer to "Comparator Setting Table" for default settings reference. *Direct mount diaphragm seal type is available upon request *Specify required document type at the time of order *Consult NAGANO KEIKI for nonstandard products Comparator Output Type J NPN Open collector (Factory Default Setting) *User selectable with ER0 K PNP Open collector Setting Value 0 Nil (Factory Default Setting) *User selectable with ER0 Set value designation Surge Protection 8 Nil (Throttle) F S5C G SUSXM7 Treatment 0 Nil Use no oil 2 Use no water 3 Use no oil/water Documents 0 Nil Required *(Price varies upon types of document) Model Name E R 0 IR COMMUNICATOR (Indicator Setting Unit) 0 0 Model Number ER0 Selective spec. Additional spec. Standard Specifications Enclosure Structure: Indore use (non-waterproof) Transmission Method: IR Communication Communication range between CE0 and ER0: Effective range within 300mm Batteries: AAA battery 2 (Rechargeable nickel-hydrogen etc.) Protective Case 0 Nil Anti-shock silicone case IR Extension Cable 0 Nil IR extension cable (2m) Documents 0 Nil *Option (Sold Separately) CE0 battery box (M2 connector cable (m) is included) USB cable: USB 2.0 micro-b (Male) - USB type A (m) *Specify required document type at the time of order Required *(Price varies upon types of document) The contents in the catalogue are subject to change without notice. URL : http://www.naganokeiki.co.jp/ HEAD OFFICE & OVERSEAS SALES DEPT -30-, HIGASHIMAGOME, OHTA-KU, TOKYO, JAPAN PHONE : +8-3-3776-5328 FAX : +8-3-3776-57 E-mail : overseas_sales_dept@naganokeiki.co.jp PRINTED IN JAPAN 6.5 0000A (SUN)