VMAX ALL FLASH FAMILY

Similar documents
VMAX ALL FLASH FAMILY

POWERMAX FAMILY. Appliance-based packaging. PowerMax 2000 and Specifications. Specification Sheet. PowerMax Arrays

DELL EMC VMAX3 FAMILY

EMC SYMMETRIX VMAX 10K

EMC SYMMETRIX VMAX 40K STORAGE SYSTEM

EMC SYMMETRIX VMAX 40K SYSTEM

EMC VMAX All Flash Product Guide

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

EMC VMAX3 Family Product Guide

ELASTIC CLOUD STORAGE (ECS) APPLIANCE

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

The Dell EMC PowerMax Family Overview

Best Practices Guide. EMC VMAX3 Family. Best Practices Guide for AC Power Connections REVISION 2.0. August, 2015

VMAX ALL FLASH. For Mission-Critical Oracle

ReDefine Enterprise Storage

Storage Platforms Update. Ahmed Hassanein, Sr. Systems Engineer

DELL EMC VPLEX FAMILY

VMAX and XtremIO: High End Storage Overview and Update

ECS APPLIANCES. Specification Sheet

Dell EMC PowerVault ME4 Series Storage

NST6000 UNIFIED HYBRID STORAGE. Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment

EMC Solutions Enabler (SE) version 8.2 and Unisphere for VMAX version 8.2 provide array management and control.

VMAX3 AND VMAX ALL FLASH WITH CLOUDARRAY

VNXe1600 BLOCK STORAGE SYSTEM

EMC VNX5100 AND VNX5300 BLOCK STORAGE

TECHNICAL SPECIFICATIONS

Dell EMC. VxBlock and Vblock Systems 740 Architecture Overview

TECHNICAL SPECIFICATIONS + TECHNICAL OFFER

DATA PROTECTION IN A ROBO ENVIRONMENT

EMC VNXe SERIES UNIFIED STORAGE SYSTEMS

ISILON HD-SERIES. Isilon HD400 ARCHITECTURE SPECIFICATION SHEET Dell Inc. or its subsidiaries.

EMC Virtual Infrastructure for Microsoft Exchange 2010 Enabled by EMC Symmetrix VMAX, VMware vsphere 4, and Replication Manager

Accelerating Microsoft SQL Server 2016 Performance With Dell EMC PowerEdge R740

ClearPath Forward Libra 8480 / 8490

EMC VMAX Best Practices Guide for AC Power Connections

Dell EMC. Converged Technology Extensions for Storage Product Guide

EMC STORAGE FOR MILESTONE XPROTECT CORPORATE

DELL EMC UNITY ALL-FLASH STORAGE

Dell EMC All-Flash solutions are powered by Intel Xeon processors. Learn more at DellEMC.com/All-Flash

EMC VMAX 400K SPC-2 Proven Performance. Silverton Consulting, Inc. StorInt Briefing

Vblock Architecture. Andrew Smallridge DC Technology Solutions Architect

Dell Fluid Data solutions. Powerful self-optimized enterprise storage. Dell Compellent Storage Center: Designed for business results

DELL EMC UNITY ALL FLASH STORAGE 300F,400F, 500F, 600F

StorNext M440 Site Planning Guide

<Insert Picture Here> Exadata Hardware Configurations and Environmental Information

EMC Innovations in High-end storages

EMC VNX SERIES UNIFIED STORAGE SYSTEMS

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

MOST ACCESSIBLE TIER 1 STORAGE

Lot # 10 - Servers. 1. Rack Server. Rack Server Server

Symantec NetBackup 5200

EMC VNX5100, VNX5300, VNX5500, VNX5700, VNX7500 UNIFIED STORAGE

Modernize with All Flash

TPC-E testing of Microsoft SQL Server 2016 on Dell EMC PowerEdge R830 Server and Dell EMC SC9000 Storage

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

Vendor must indicate at what level its proposed solution will meet the College s requirements as delineated in the referenced sections of the RFP:

Upgrade to Microsoft SQL Server 2016 with Dell EMC Infrastructure

SUN ZFS STORAGE 7X20 APPLIANCES

L'innovation au cœur de votre Data Centre. Christophe Grenier Senior System Engineer

IBM System Storage DCS3700

MODERNISE WITH ALL-FLASH. Intel Inside. Powerful Data Centre Outside.

ISILON X-SERIES. Isilon X210. Isilon X410 ARCHITECTURE SPECIFICATION SHEET Dell Inc. or its subsidiaries.

DELL EMC UNITY: BEST PRACTICES GUIDE

DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND FIBRE CHANNEL INFRASTRUCTURE

ftserver 3300 Service Bulletin

Microsoft SQL Server in a VMware Environment on Dell PowerEdge R810 Servers and Dell EqualLogic Storage

EMC Symmetrix DMX Series The High End Platform. Tom Gorodecki EMC

Dell PowerEdge R720xd with PERC H710P: A Balanced Configuration for Microsoft Exchange 2010 Solutions

Quest DR Series Disk Backup Appliances

IT Certification Exams Provider! Weofferfreeupdateserviceforoneyear! h ps://

EMC VMAX3 & VMAX ALL FLASH ENAS BEST PRACTICES

Exam : Title : Storage Sales V2. Version : Demo

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

Quest DR Series Disk Backup Appliances

VSTOR Vault Mass Storage at its Best Reliable Mass Storage Solutions Easy to Use, Modular, Scalable, and Affordable

E-Series Site Preparation Guide

Dell PowerVault MD Family. Modular storage. The Dell PowerVault MD storage family

Data Protection for Cisco HyperFlex with Veeam Availability Suite. Solution Overview Cisco Public

Cisco MCS 7828-I5 Unified Communications Manager Business Edition 5000 Appliance

DELL EMC UNITY ALL-FLASH STORAGE

EMC XtremIO All-Flash Applications. Sonny Aulakh VP, Sales Engineering November 2014

SAN Storage Array Workbook September 11, 2012

vstart 50 VMware vsphere Solution Specification

SPECIFICATION FOR NETWORK ATTACHED STORAGE (NAS) TO BE FILLED BY BIDDER. NAS Controller Should be rack mounted with a form factor of not more than 2U

Dell PowerEdge M905, M805, M605, and M600. Getting Started With Your System

DELL EMC DATA DOMAIN OPERATING SYSTEM

Suggested use: infrastructure applications, collaboration/ , web, and virtualized desktops in a workgroup or distributed environments.

DELL EMC DATA DOMAIN OPERATING SYSTEM

Dell PowerVault NX Windows NAS Series Configuration Guide

DELL POWERVAULT NX3500. A Dell Technical Guide Version 1.0

CONNECTRIX DS-6500B SWITCHES

SPC BENCHMARK 2 EXECUTIVE SUMMARY EMC CORPORATION EMC VMAX 400K SPC-2 V1.5. Submitted for Review: July 30, 2015 Submission Identifier: B00073

DELL EMC UNITY ALL-FLASH STORAGE

IBM System Storage SAN768B

VxBlock System Deep inside the next generation converged infrastructure

IBM Storwize V7000 Unified

HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array hardware configuration guide

EMC Integrated Infrastructure for VMware. Business Continuity

Transcription:

VMAX ALL FLASH FAMILY VMAX 250F, The exciting Dell EMC VMAX family of all-flash arrays now includes the newest powerful member, the VMAX. The VMAX delivers unparalleled performance and scalability as a mission-critical multi-controller platform utilizing Intel Xeon E5-2697-v4 18 core processors running at 2.3GHz. With the highest capacity 7.68 and 15.36TB Enterprise Flash drives, and Dual V-Brick/cabinet packaging this new Enterprise class array offers a compelling value proposition designed for the most demanding storage workloads, including new support for Mixed Mainframe and Open Systems hosts. Like all members of the All Flash family, your data always resides in the fastest possible tier (Diamond) to deliver the highest IOPS throughput and lowest possible latency. VMAX All Flash VMAX All Flash arrays extend the long tradition of VMAX Reliability, Availability and Serviceability that our customers have come to expect. A single V-Brick is architected to provide six-nines (99.9999%) of Availability in the most demanding, mission critical environments. Ranging from 1 to 8 V-Bricks packaged in dual V-Brick racks along with their associated DAEs, the VMAX All Flash family offers unprecedented scale and footprint efficiency. The built-in hypervisor enables VMAX All Flash to offer Unified block and file support through Embedded NAS (enas), as well as Embedded Management. VMAX All Flash arrays are available in two software packages, the standard F package and the application rich FX package, which makes ordering easy. The FX package includes licensed support for SRDF S/A/STAR/Metro, Data at Rest Encryption, enas, and both include VASA Provider Certified support for VVols, and Secure Snaps, a new SnapVX feature eliminating the ability for admins to delete snapshots. And now, for the first time, VMAX All Flash arrays offer the optional support for RecoverPoint for heterogeneous replication with Dell EMC arrays. As always, VMAX All Flash arrays come fully pre-configured out of the factory to significantly shorten the time to first I/O. Specifications Appliance-based packaging The Dynamic Virtual Matrix Architecture that allows aggregate scaling of system resources has been extended to VMAX All Flash Arrays, where basic storage building blocks are defined by appliance-based entities called V- Bricks. Each V-Brick includes an engine with two VMAX directors, packaged software, and, depending on the platform, from 512 GB to 2 TB of cache, and two 25-slot Drive Array Enclosures housing a minimum base capacity of 13.2 TBu of flash capacity in the VMAX 250F, or two 120-slot Drive Array Enclosures with minimum base capacities of 13.2 TBu for 100% CKD MF systems, and 53.6TBu for Open Systems on the VMAX. Multi V-Brick systems also include redundant InfiniBand interfaces to connect all V-Bricks in the array. Additional flash capacity can be added to each V-Brick in varying increments up to a total usable capacity of 4.4 PB on the VMAX, along with inline compression, supported on all members of the VMAX All Flash family. Inline compression is supported across the entire VMAX All Flash family as of the Q3 2016 HYPERMAX 5977 release. Each director consolidates front-end, global memory, and back-end functions, enabling direct memory access to data for optimized I/O operations. Depending on the array chosen, up to eight (8) VMAX All Flash V- Bricks can be supported for highly scalable performance and high availability. Additional specifications and a comparison of the VMAX 250F and arrays follow. VMAX All Flash Family 2018 Dell Inc. or its subsidiaries.

Array family VMAX 250F/VMAX 250FX VMAX /VMAX X V-BRICKS Number of V-Bricks 1 to 2 1 to 8 ENGINE ENCLOSURE 4u 4u CPU Intel Xeon E5-2650-v4 Intel Xeon E5-2697-v4 4 2.5 GHz 12 core 4 2.8 GHz 18 core # CORES PER CPU/PER ENGINE/PER SYSTEM DYNAMIC VIRTUAL MATRIX INTERCONNECT CACHE 12/48/96 18/72/576 Direct Connect InfiniBand 56 Gbps per port InfiniBand Dual Redundant Fabric: 56 Gbps per port CACHE-SYSTEM MIN (RAW) 512 GB 1,024 GB CACHE-SYSTEM MAX (RAW) 4 TB (with 2,048 GB engine) 16 TB (with 2,048 GB engine) CACHE-PER ENGINE OPTIONS 512 GB, 1 TB, and 2 TB 1 TB, 2 TB VAULT VAULT STRATEGY Vault to Flash Vault to Flash VAULT IMPLEMENTATION 2 to 4 NVMe Flash SLICs / Engine 4 to 8 NVMe Flash SLICs / Engine FRONT END I/O MODULES MAXIMUM FRONT-END I/O MODULES/V-BRICK FRONT-END I/O MODULES AND PROTOCOLS SUPPORTED enas I/O MODULES MAX enas I/O MODULES/ SOFTWARE DATA MOVER enas I/O MODULES SUPPORTED 8 6 (up to 8 on Mainframe) FC: 4 x 8 Gbs (FC, SRDF) FC: 4 x 16 Gbs (FC, SRDF) 10 GbE: 4 x10 GbE(iSCSI, SRDF) GbE: 4 x 1 GbE(2 Cu/2 Opt SRDF) 5 3 5 3 10 GbE: 2 x 10 GbE Optical 1 10 GbE: 2 x 10 GbE Cu 2 8 Gbs: 4 x 8 Gbs FC (Tape BU) FC: 4 x 8 Gbs (FC, SRDF) FC: 4 x 16 Gbs (FC, SRDF) 10 GbE: 4 x10 GbE (iscsi, SRDF) GbE 4 x 1 GbE (2 Cu/2 Opt SRDF) FICON: 4 x 16 Gbs (FICON) 10 GbE: 2 x 10 GbE Optical 1 10 GbE: 2 x 10 GbE Cu 2 8 Gbs: 4 x 8 Gbs FC (Tape BU) enas SOFTWARE DATA MOVERS MAX SOFTWARE DATA MOVERS 4 (3 Active + 1 Standby) (4 Data Movers requires minimum 2 V-Bricks) 3 8 (7 Active and 1 Standby) MAX NAS CAPACITY/ARRAY 1158 (cache limited) 3584 (TERABYTES USABLE) 1 Quantity one (1) 2 x 10 GbE Optical module is the default choice/data Mover. 2 Used to support NDMP Tape Backup 3 Support for 8 Data Movers on the VMAX /FX is available by request. 4 CPUs run in Turbo Mode except at elevated ambient temperatures. 5 Two enas I/O modules/datamover standard. Three can be supported depending on configuration via RPQ. (8 Data Movers requires minimum 4 V-Bricks)

Array family VMAX 250F/VMAX 250FX VMAX /VMAX X CAPACITY, DRIVES Max Capacity per Array (Open) 1 1.16 PBe 4.42 PBe Base Capacity per V-Brick (Open) 3 13.2 TBu 52.6 TBu Base Capacity per V-Brick (Mainframe) N/A 13.2 TBu Incremental Capacity Blocks 3 13.2 TBu 13.2 TBu Max Drives per V-Brick 50 240 Max Drives per Array 100 1,920 Max Drives per System Bay 100/200 2 480 Min Drive Count per V-Brick 8 + 1 Spare 16 + 1 spare FLASH DRIVES Flash Drives Supported (2.5 ) 960 GB, 1.92 TB, 3.84 TB, 7.68 TB, 15.36 TB 960 GB, 1.92 TB, 3.84 TB, 7.68 TB, 15.36 TB BE Interface 12 Gbps SAS 6 Gbps SAS RAID Options Supported RAID 5(7+1) (default) RAID 5(3+1) RAID 6(6+2) Mixed RAID Group Support No No Support for Mixed Drive Capacities Yes Yes FLASH ARRAY ENCLOSURES 120 x 2.5 Drive DAE No Yes 25 x 2.5 Drive DAE Yes No CABINET CONFIGURATIONS Standard 19" bays Yes Yes RAID 5(7 +1) RAID 6(14+2) Single V-Brick System Bay Configuration Dual V-Brick System Bay Configuration No (Packaging based on Dual V-Bricks, but initial V-Brick in each System Bay supported) Yes (Default packaging) No (Packaging based on Dual V- Bricks, but initial V-Brick in each System Bay supported) Yes (Default packaging) Third Party Rack Mount Option Yes Yes DISPERSION Third Party Rack Mount Option N/A-single floor tile system Yes (on request) PRE-CONFIGURATION FROM FACTORY 100% Thin Provisioned Yes Yes HOST SUPPORT Open Systems Yes Yes Mainframe No Yes Mixed Mainframe and Open No Yes POWER OPTIONS Single or Three Phase Single or Three Phase Input Power Options Delta or Wye Delta or Wye 1 Max capacity per array based on over provisioning ratio of 1.0. 2 200 drives can be supported in a single cabinet when two systems are packaged in the same rack. 3 13.2TBu V-Brick and Capacity Block usable capacities are based on RAID 5 (7+1). 11.3TBu base capacity and Capacity Block increments possible with RAID 5(3+1) on VMAX 250F

Array family VMAX 250F/VMAX 250FX VMAX /VMAX X I/O PROTOCOLS SUPPORTED 8 Gb/s FC Host/SRDF Ports 16 Gb/s FC Host Ports 16 Gb/s FICON Host Ports Maximum/V-Brick N/A 32 Maximum/array N/A 256 10 GbE iscsi Ports (Optical) 10 GbE SRDF Ports (Optical) GbE SRDF Ports (Optical/Cu) Maximum/V-Brick 16/16 12/12 Maximum/array 64 96 Embedded NAS ports 10 GbE Optical Ports Max ports/software Data Mover 4 4 Maximum ports/array 16 32 10 GbE Copper Ports Max ports/software Data Mover 4 4 Maximum ports/array 16 32 8 Gb/s FC Tape Back Up Ports Max ports/software Data Mover 2 2 Maximum ports/array 8 16

System bay dispersion System Bay Dispersion allows customers to separate any individual or contiguous group of system bays by up to a distance of 82 feet (25 meters) from System Bay 1. This provides unsurpassed datacenter flexibility in solving floor loading constraints or working around obstacles that might preclude fully contiguous configurations. This is applicable to VMAX, as the VMAX 250F is a single bay solution. Flash drive support The VMAX 250F/FX (12 Gb/s) and the 450F/FX and 850F/FX (6 Gb/s) support the latest dual ported native SAS Flash drives. All Flash drives support two independent I/O channels with automatic failover and fault isolation. Check with your Dell EMC sales representative for the latest list of supported drives and types. All capacities are based on 1 GB = 1,000,000,000 bytes. Actual usable capacity may vary depending upon configuration. 2.5 support flash drives used in V-Bricks and capacity upgrades VMAX 250F, VMAX 250F, VMAX 250F, VMAX 250F, Platform support VMAX 250F, Nominal capacity (GB) 1 960 1 1920 1 3840 1 7680 1 15360 Type Flash Flash Flash Flash Flash Average seek time (read/write ms) N/A N/A N/A N/A N/A Raw Capacity (GB) 960 1920 3840 7680 15360 3 Open systems formatted capacity (GB) 938.94 1879.64 3761.03 7522.06 15047.65 Mainframe 3390 formatted capacity 2 940.26 2 1880.52 2 3761.80 2 7523.61 2 15047.98 1 V-Bricks and capacity upgrades in any given configuration could contain a maximum of two different underlying drive sizes in order to best achieve the desired usable capacity. This is automatically optimized by the VMAX Sizer Tool. 2 Mainframe is not supported on VMAX 250F. 3 Open systems formatted capacity is also referred to as TBu in this document.

Power consumption and heat dissipation at <26 and >35 degrees C Component VMAX 250F/FX VMAX /FX Maximum power and heat dissipation at temperatures <26 C and >35 C 2,3 Maximum Total power consumption (kva) Maximum Heat dissipation (Btu/hr) Maximum Total power consumption (kva) Maximum Heat dissipation (Btu/hr) <26 o C >35 o C <26 o C >35 o C <26 o C >35 o C <26 o C >35 o C System bay 1, dual engine 4.13 5.19 14,090 17,698 7.25 9.61 24,712 32,760 System bay 2, dual 1 N/A N/A N/A N/A 6.80 8.90 23,178 30,339 engine 1 Power values for System Bay 2 and all subsequent system bays where applicable. 2 Power values and heat dissipations shown at >35 degrees C reflect the higher power levels associated with both the battery recharge cycle, and the initiation of high ambient temperature Adaptive Cooling algorithms. 3 Values at <26 C are reflective of more steady state maximum values during normal operation. Physical specifications Component Height (in/cm) Width (in/cm) Depth (in/cm) Weight (maximum lbs/kgs) System bay, dual engine 75/190 24/61 47/119 1860/844 System bay, dual engine 250F 75/190 24/61 42/106.7 850/385 System bay, dual engine, dual system 250F 75/190 24/61 42/106.7 1410/640 Input power requirements Single phase North American, international, Australian Specification North American 3-wire connection (2 L and 1 G) 1 International and Australian 3-wire connection (1 L and 1 N and 1 G) 1 Input nominal voltage 200 240 VAC +/- 10% L- L nom 220 240 VAC +/- 10% L - N nom Frequency 50 60 Hz 50 60 Hz Circuit breakers 30 A 32 A Power zones Two Two Power requirements at customer site (min) One 30A, single phase drop per zone (250F) Three 30A, single phase drops per zone () Two power zones require 2 drops (250F), 6 drops () with each drop rated for 30A 1 L = line or phase, N = neutral, G = ground

Three-phase North American, international, Australian Specification North American (DELTA) 4-wire connection (3 L and 1 G) 1 International (WYE) 5-wire connection (3 L and 1 N and 1 G) 1 Input voltage 2 200 240 VAC +/- 10% L- L nom 220 240 VAC +/- 10% L - N nom Frequency 50 60 Hz 50 60 Hz Circuit breakers 50 A 32 A Power zones Two Two Power requirements at customer site (min) Two 50 A, three-phase drops per bay Two 32 A, three-phase drops per bay 1 L = line or phase, N = neutral, G = ground 2 An imbalance of AC input currents may exist on the three-phase power source feeding the array, depending on the configuration. The customer's electrician must be alerted to this possible condition to balance the phase-by-phase loading conditions within the customer's data center Radio frequency interference Electro-magnetic fields which include radio frequencies can interfere with the operation of electronic equipment. Dell EMC products have been certified to withstand radio frequency interference in accordance with standard EN61000-4-3. In Data Centers that employ intentional radiators, such as cell phone repeaters, the maximum ambient RF field strength should not exceed 3 Volts /meter. Repeater power level (watts) Recommended minimum distance (feet/meters) 1 9.84 FT (3 M) 2 13.12 FT (4 M) 5 19.69 FT (6 M) 7 22.97 FT (7 M) 10 26.25 FT (8 M) 12 29.53 FT (9 M) 15 32.81 FT (10 M) Learn more about Dell EMC VMAX All Flash Contact a Dell EMC Expert View more resources Join the conversation with #VMAXAllFlash 2018 Dell Inc. or its subsidiaries. All Rights Reserved. Dell, EMC and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners. Reference Number: H16051.4