Cable into the Future: Industrial Ethernet with 10 Gbps

Similar documents
Recent Changes in the Physical Layer (Chapter 8) for DeviceNet and EtherNet/IP

PHOENIX CONTACT - 11/2008

History of Standards

PHOENIX CONTACT - 10/2009

The AMP NETCONNECT Category 6 Cabling System

Ethernet and PoE Operation Over Single Pair Twisted-Pair Copper Cabling (SPE) Chris DiMinico AEM Technical Sales Test and Measurement

Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation

Certification for 10G copper cabling

Mosaic TM LCS2 Cat. 6 RJ 45 socket

White paper. Field Testing of Direct Attach Modified Permanent Links. occfiber.com

onlinecomponents.com

Cat.8 Shielded Field Termination Plug Description

Telegärtner Point of View

NGBASE-T Cabling Requirements

FL SWITCH 8TX. Extract from the online catalog. Discontinued item. Order No.:

Fig. 1: Entry Line Compact Gigabit Ethernet Converter

4Cu-LSA Connection technology

EMOSAFE EN-30 1 FEATURES AND ADVANTAGES 2 GENERAL DESCRIPTION. Product Datasheet. Gigabit Network Isolator in aluminium housing December 2015 ENGLISH

FL MC 2000E (SM40) LC

Pro 21/Galea/Sistena socket for LCS 6 Category 6

The module for the highest standards, guarantees the best performance in the 10 Gigabit Ethernet cabling.

Mosaic TM LCS2 Cat. 6 RJ 45 socket

The AMP NETCONNECT Category 6 Cabling System

Valueline Industrial PC

Surge protection for closed-circuit television systems (CCTV) Guide for support in planning and installation. Building Connections

Innovative Magnetic Connector Solution for Ethernet Connections. Magnetic RJ45 MEDICAL & INDUSTRIES

FL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H.

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards

Product information 19" 3U Global Patch Panel 48xRJ45/u, Cat. 6, partly populated R302361

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Cat.8 Shielded Keystone Jack Description

Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print"

FL SWITCH SFN 5TX. Extract from the online catalog. Order No.:

Product information Patch Cord Cat. 6A, S/FTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 1.0 m

[0.057] 5.8 [0.23]

LANmark-7A H i g H - S p e e d C O p p e R S O l u t i O n F O R 4 0 g i g a b i t a p p l i C a t i O n S

[0.057] 5.8 [0.23]

PHOENIX CONTACT - 07/2006

Circular M8/M12 Interconnect Solutions for Industrial applications

Standards Update. by Paul Kish NORDX/CDT

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

Quick Start Guide. Installation. User s Manual 1

High Performance Network Isolator

Standards Update. Mylaraiah J N, RCDD Member, BICSI India Steering Committee

EMOSAFE EN-85e Network Isolator with Overtension Auto-Release

COUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only

FL SWITCH SFN(T) 16-Port Standard Function Ethernet Switches for Normal and Extreme Environments. AUTOMATION Data Sheet 2806_en_C

TF501, TF521 Terminal Bases

Plug & Play Universal Harness, SMF-28 Ultra Single-mode (OS2)

Product Information. ECN 1023 EQN 1035 Rotary Encoders with EnDat 2.2 for Safety-Related Applications

FREQUENTLY ASKED QUESTIONS (FAQs)

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

PHOENIX CONTACT - 01/2008

LCS² Cat. 6A RJ45 Socket

RAD-WHG/WLAN-XD. WirelessHART gateway with integrated WLAN (802.11b/g) INTERFACE Data Sheet 2720_en_C. 2 Features. 1 Description

INTERNATIONAL STANDARD

EMOSAFE EN-10 Network Isolators with Protected Connector

Industrial Field-Bus Standards Update (Physical Layer)

Type ME43. Quickstart

Data sheet C6 A modul 1 port 180 M AP pure white

Signature Core Fiber Optic Cabling System

MINI MCR-SL-UI-2I(-SP)(-NC)

Introduction. Standards

PUBLICLY AVAILABLE SPECIFICATION. Pre-Standard. Connectors for electronic equipment

Category 8 paves the way for IEEE 40GBASE-T. David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope

PSI-MODEM-SHDSL/SERIAL

Independent Testing - For End User Confidence

Field-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.

TU531, TU532 Terminal Unit

Installing the Right Ethernet Interconnect to Ensure Reliable Performance in Aircraft. White Paper

History Channel. 10G Ethernet on Copper

onlinecomponents.com

Application Note. Data Center Standards and Layouts

MFP8 Cat.6 A Field assembly RJ45 plug series. Simpler all over. Simpler all round. Data Voice. PoE+ 500 MHz. Cat.6 A.

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Single-pair cabling channel specifications

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

E-DAT C6A. The compact connection system of course with Cat.6A

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Data sheet C6 A modul 90 jack

FL SWITCH Factoryline 5- and 8-port managed switches with optional fiber optic ports and wide temperature ratings. Data sheet.

AMP-TWIST* 6S Series SL Jack

10/100Base-TX Industrial Ethernet Extender

Designing the Right Ethernet Interconnect to Increase High-Speed Data Transmission in Military Aircraft. White Paper

MED MI 1005 Network Isolators

Enterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

Better all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded.

CLIPLINE complete. The modular terminal block system for all applications

EDGE8 MTP Trunk Cable

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

PHOENIX CONTACT - 05/2007

Redundancy Module QUINT-DIODE/40

INTERNATIONAL STANDARD

DIS-2 series Decentralised servo drive

Quick Install Manual BACnet /IP Controller

Transcription:

Cable into the Future: Industrial Ethernet with 10 Gbps A White Paper presented by: Bernd Horrmeyer Industrial Network Cabling Specialist Phoenix Contact GmBH & Co. KG Blomberg, Germany Phoenix Contact USA P.O. Box 4100 Harrisburg, PA 17111-0100 Phone: 717-944-1300 Fax: 717-944-1625 Website: www.phoenixcontact.com

1 Cable into the Future: Industrial Ethernet with 10 Gbps Today s machines and plants generally communicate using Ethernet with 100 megabits per second (Mbps). However, many applications, such as cameras for quality inspection, servers to document quality data and scanners that identify components, demand higher data rates. Frequently, communications also must be established with the factory control system. While data transmission rates of 1 gigabit per second (Gbps) are standard, 10 Gbps will be necessary in the near future (Fig. 1). Classic fieldbuses and generic cabling can no longer meet the requirements of these networks. Automation-related applications are subject to the same demanding environmental conditions as fieldbus communication. To reliably transmit data in this environment, the components must be able to cope with the mechanical effects as well as the high electromagnetic load. Figure 1. Today, Cat6 A components allow 10 Gb Ethernet to be reliably used in an industrial environment. CAT6A is not the same as Cat6 A Different standards exist to implement a channel for 10 Gb Ethernet. The American TIA (Telecommunications Industry Association) 568B standard describes a CAT6A channel that is achieved with category CAT6A components. Cable configurations according to CAT6 should still be used if at all possible. Figure 2. Lower signal clearances for Gigabit Ethernet with PAM (Pulse Amplitude Modulation) increase the danger of disturbances when compared to Fast Ethernet with MLT (Multi Link Trunk). Because CAT6 is defined only up to 250 MHz, only a reduced transmission-related quality is defined for the frequency range from 250 to 500 MHz (Fig. 3). The incorrect interpretation of a signal occurs far more frequently. This means that it is necessary to repeat the Ethernet packet. Office applications can tolerate this, since the only effect is slower data transmission. However, this is not acceptable in the industrial area, with its real-time

2 requirements. Each signal must be reliably transmitted to avoid having to repeat packets. As a consequence, designing a channel according to standard TIA 568B is insufficient for the industrial environment. Standard ISO/IEC TR24750 shows how an existing network can be qualified for 10 Gb Ethernet. This standard can be used for existing cable sections where measurements can prove that it is suitable for 10 Gb Ethernet transmission. This can often be achieved with good CAT6 components, careful cable routing and short channel lengths. However, it is not possible to configure new channel types. Several components on the market, with attributes such as suitable for 10 Gb Ethernet, refer to the standard, but they are not CAT6A or Cat6 A components. An additional standard to consider is ISO/IEC 11801. Amendment 1 defines the requirements placed on a channel. Class E A is specified for 1 to 500 MHz without reducing the quality (Fig. 3). This avoids the risk of a high-frequency signal transmission error and the resulting repetition of the Ethernet frame packet. Real-time systems as well as systems with a high data rate can also be reliably configured. Amendment 2 describes the requirements of Cat6 A components used in the Class E A channel. Figure 3. The TIA and IEC committees assume different NEXT values (near end crosstalk) across the frequency range. The planned configuration of a new channel without incurring the risk of a data transmission error is possible only when Cat6 A components are used. Only this channel signified by the A as subscript permits reliable data transmission in the industrial environment, with its wide range of disturbance sources. Cabling Standards The communication-related infrastructure of buildings with their ISDN telephone communication and Ethernet applications is based on generic cabling. ISO/IEC 11801 describes the structure and quality of the components. ISO/IEC 24702 is a supplemental standard for industrial buildings. It considers the specific conditions, such as temperature and the environment, which can affect an industrial application. Category, Channel and Class Under the ISO/IEC 11801 and 24702 standards, the channel includes all of the cabling between two active devices. The various quality stages are designated with the Class and the associated component qualities with the Category. The table shows these interrelationships and, therefore, the maximum number of possible Ethernet versions.

3 Table 1. Class and Category Class D D E E A F F A Category 5 5 6 6 A 7 7A Frequency 100 100 250 500 600 1000 (MHz) Ethernet 100Base- 1000Base-T 1000Base-T 10GBase-T - - TX Data rate 100 1000 1000 10000 - - (Mbps) Pairs 2 4 4 4 - - Standard Cable Cross Section The voltage differences between signals for 1 Gb and 10 Gb Ethernet are minimal, according to IEEE 802.3, and even slight disturbances can reduce the information content (Fig. 2). IEEE assumes disturbances that are applicable for the office environment. Disturbances in an industrial environment are generally more extreme and demand the appropriate protective measures. Figure 4. Low NEXT values increase the level of disturbance coupled in from adjacent pairs and are added to external disturbances. This means that shielded components, which correspond to standard Cat6 A, are that much more important. The coupling attenuation (a measure of the shield quality) should reach 80 db. This results in a rating of separating class d according to EN 50174-2, which allows communication cables to be routed with almost no clearance to power cables (Fig. 4). For generic cabling with its reference implementation, a channel length of 100 m is achieved with a rigid system of horizontal and patch cables. In the industrial environment, for the various subsections, cables with varying quality and cross sections are used. The reference implementation model is not sufficient here. Using the appropriate formulas, a check must be made as to whether the transmission section maintains the values required for the channel. This method is complex and inflexible. If this method is not to be applied, then a horizontal cable with AWG 24 must be routed in the complete channel. These considerations apply for up to 20 degrees Celsius. Higher temperatures typical for industrial applications can also be taken into consideration from a theoretical perspective. As a consequence, the user can calculate a channel with several subsections with different temperature profiles. This calculation is not required if a cross section of AWG 22 is used throughout the system being considered.

4 Plug Connectors Must Remain User-Friendly The plug connectors are just as important as the cables. Cables with cross sections of AWG 24 or AWG 22 require special versions. Cables sold by the meter are generally used in industry. This requires simple connection of plug connectors without the use of special tools. Cables must be routed so that the data transmission quality is automatically maintained. Quick connection technologies (such as Phoenix Contact s Quickon and Piercecon) allow a high-quality connection in compliance with the requirements of Cat6 A. The assembly of plug connectors in the field generally used in industry is therefore now also possible for 10 Gb Ethernet. This means it is no longer necessary to rethink planning and installation a decisive advantage. Plug connectors can be roughly classified according to their use in the control cabinet or in the field. In the first case, the usual RJ45 mating face can be used up to Cat6 A. An especially good 360-degree shielding is necessary to minimize the EMC effects of neighboring devices such as frequency converters. High-quality surfaces will prevent gases from causing contact corrosion thereby preventing a creeping aging process, which can result in the connection failing due to higher transition resistances. Over the long term, the usual patch cables from the office environment do not fulfill the reliability requirements that industrial applications call for. For use in the field, RJ45 plug connectors with a special protective housing and M12 plug connectors have established themselves on the market. Also in this case, Cat6 A is already possible with the new M12 plug connectors according to IEC 61076-2-109 (International Electrotechnical Commission). The same is true for RJ45 connectors. Conclusion Sophisticated and demanding tasks that require the extended use of automation technology can now use cabling solutions that are fit for the future. 10 Gb Ethernet can be transmitted via a class E A channel in line with industrial requirements using Cat6 A components. With well-designed, industrial-grade components, planning and installation can become routine. About Phoenix Contact Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment for a wide range of industries. Phoenix Contact GmbH & Co. KG, Blomberg, Germany, operates 47 international subsidiaries, including Phoenix Contact USA in Middletown, Pa. Phoenix Contact s formal Integrated Management System is registered to ISO quality, environmental and safety standards (ISO 9001:2008, 14001:2004 and OHSAS 18001:2007).