EasyBuilder Pro V [LB-12053: Failed to send an [Event Log] (when ON)]: When . sending fails, this register will be set ON.

Similar documents
EasyBuilder 8000 V [LB-12052: MODBUS server status (disabled when ON)]: When this. register is set ON, the MODBUS Server will be disabled.

1. Added [Scroll bar] feature in [System Parameter Settings]» [Model] tab. This

EasyBuilder Pro V This model is a gateway device; therefore, it is not possible to generate a

EasyBuilder Pro V Added [Scrolling control address] setting in Event Display object and Alarm

EasyBuilder Pro V Build

Software Version:EasyBuilder Pro V

EasyBuilder Pro V screen and editing the project with the Work Space window open.

1. By adding [MODBUS Server] with [Ethernet] interface, the [MODBUS TCP/IP. Gateway] feature can be enabled by selecting the [Enable] checkbox.

EasyBuilder Pro V Fixed the problem where macro function FLOAT2ASCII may do incorrect

Software Version:EasyBuilder Pro V

19.Configure HMI as a MODBUS Server

EasyBuilder Pro V Added Daylight Saving Time (DST) feature in [System Parameters] and the

13-1. This chapter explains how to use different objects.

EasyBuilder Pro V Added Combo Button object to HMI models: ie, emt, and XE.

EasyBuilder Pro V EasyBuilder Pro V is no longer available for download for the following

Version /04/27

EasyBuilder 8000 Version Build 2013/05/ Virtual com port and USB download drivers support Windows 7 64bit

EasyBuilder 8000 Version

Version /09/17

7-1. This chapter explains how to set and use Event Log Overview Event Log Management Creating a New Event Log...

EasyBuilder Pro V Added the following new features to the editing window in this release:

4-1. This chapter explains HMI settings.

EasyBuilder Pro V Upgraded cmt Viewer to version 2.0, in which Monitor Mode is added.

4-1. This chapter explains HMI settings.

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

Software Version: EasyBuilder Pro V

EasyBuilder Pro Installation and Startup Guide

7-1. This chapter explains how to set and use Event Log Overview Event Log Management Creating a New Event Log...

8-1. This chapter explains how to set and use Data Sampling.

Set HMI as a MODBUS Server

PM Designer Version Product Release Notes

cmt Quick Start Guide

3.1 Updating Web Package Updating OS... 16

Pass-Through Function

2.1. Project Information and Protection Global Settings Working with Tags... 15

T E C H N I C A L N O T E N/A

Expressive. Expression 32,768. Product Features. The 32,768 full-color display gives clear and bright images equivalent to photos.

Certification according to CE. C-more Touchpanels:

Certification according to CE. C-more Touchpanels:

Welcome to the C-more Micro Programming Software Version (Nov 15, 2017)

TPEditor User Manual

Recipe Editor. Figure 26.1

Display. Control elements

Cloud Human Machine Interface SERIES

CREATING PANEL APPLICATIONS

User. Manual. cmt-hdm Startup Guide. Weintek USA, Inc. (425)

Comparison of HMI900 Series to HMI500 Series

JMobile V2.6 SP1 Release Notes

Silver Series EM Operator Interface Terminal

10.User Password and Object Security

1.STARTUP FUNDAMENTALS...21

Display. Control elements

General information. Display. Control elements

Sysmac Studio System requirements

General information. Display. Control elements

25 Saving Setting Guide Import/Export Nodes and Symbols

General information. Display. Control elements

General information Customer-specific configuration

6AV6542-0CA10-0AX0. Available as a Spare Part Only - subject to availability - SIMATIC OP270 6" OPERATOR PANEL 5.7" STN COLOR DISPLAY Supply voltage

User. Manual. cmt-fhd Startup Guide. Weintek USA, Inc. (425)

EZTouch Programming Software README for General Information, February 19, 2004 (c) Copyright Autotech Technologies, L.P. 2002

BU CT Compact Product Suite Panel 800 Version 6. ABB BU CT 3BSE en Slide 1

General information. Display. Control elements

Recipe Function. Sample Screen Manual. Mitsubishi Electric Corporation

General information. Display. Control elements

Display Design of display Screen diagonal. Control elements

*** If you have a Quick Designer project skip this section ***

JMobile V2.0 Exor_template_v1.01

CROUZET TOUCH QUICK START

GP-PRO/PBIII for Windows Device/PLC CONNECTION MANUAL ADDITIONAL MANUAL. Hioki E.E. Corporation Controller Smart Site

In this tutorial, we are going to demonstrate how to connect the Weintek ip series HMI device with UniPi controller running Mervis.

Contents. Part 1: Welcome. Part 2: Getting Started. Part 3: Demo Version Notes

EnerVista Integrator Version 6.16 Specification

Check the contents of the error (= error number) according to the item name and sub-item number, and remove the error.

HMI Touch Display CGHMI 4.3, 7, 10, 15


HMI Touch Display CGHMI 4.3, 7, 10, 15

Operating a Power Xpert C445 Global Motor Management Relay with a Rockwell PLC via Ethernet/IP

OMRON Rockwell CompactLogix or ControlLogix

EtherNet/IP Configuration for a Moxa MGate 5105-MB-EIP and an Allen-Bradley CompactLogix L32E. Copyright 2013 Moxa Inc Released on July 15, 2013

SAPGUI for Windows - I18N User s Guide


Automation Software. Automation & Sensing. Selection Guide Automation Organizer Suite WindO/I-NV WindLDR WindCFG...

T40 - What's New in Connected Components Workbench Software?

Human Machine Interfaces

User Manual. cmt-iv5 Startup Guide

AUTOMATION.CROUZET.COM 7 CROUZET TOUCH HMI AUTOMATION & CONTROL. New HMI. for & automation.crouzet.com

Using the Panasonic GT01 HMI with Exlar s Tritex Drive

Table of Contents. Chapter 1: Getting Started. Chapter 2: Specifications

NB-Series Operator Interface Terminals

ABB Modbus RTU Driver for JMobile

JMobile Suite User Manual

G9SP Ethernet IP Communication to Omron s NJ5 PLC s Rev1.0 Mike Wash

Open Cases for ix Developer 1.30

PanelMate Power Pro Version 2.21 Errata

Release Notes ClearSQL (build 181)

Omron FINS Ethernet Driver for JMobile

Device/PLC Connection Manuals

HCiX Series ( Honeywell Controller Interface)

User Manual. cmt-svr Startup Guide

Transcription:

Software Version: EasyBuilder Pro V4.10.02 Build 2014.04.17 New Features 1. Added new system registers: [LB-12053: Failed to send an [Event Log] e-mail (when ON)]: When e-mail sending fails, this register will be set ON. [LB-12054: Failed to send an [Backup Object] e-mail (when ON)]: When email sending fails, this register will be set ON. [LB-12052: MODBUS server status (disabled when ON)]: When this register is set ON, the MODBUS Server will be disabled. [LW-9051 (16bit): audio volume (0 ~100)] [LW-10900~LW-11154 (16bit): macro 0~254 status (0:ready, 3:executing, 5:waiting PLC response, 9:waiting sync, 17:delay)] The individual bit in these registers provides detailed information on Macro status. LW_Bit can be used to get this information. Bit 0 indicates whether the Macro is triggered. Bit 0 = ON: Macro is triggered. Bit 1 to Bit 4 indicate the progress of Macro. Bit 1 = ON: Macro is running normally. Bit 2 = ON: Waiting for the reply from PLC, Macro is paused. Bit 3 = ON: Executing SYNC_TRIG_MACRO() command, Macro is paused. Bit 4 = ON: Executing DELAY() command, Macro is paused. [LB-12041: refresh HMI IP (LW-9129~9132) (set ON)]: When this register is set ON, the system will refresh the HMI IP information in LW-9129~9132 registers.

2. When the font used in the project file is not installed on PC, a Replace Font dialog box is displayed. This dialog box can only be closed when a replacement font is selected. 3. Added [Enable delete history data function] check box in Option List settings dialog box. The history data of specific dates can be deleted. 4. Added [File name prefix] check box in Data Sampling settings dialog box. A specified prefix can be added in the history file name.

As shown in the preceding figure, enter HMI_A_ in the field, and the file name will be (for example): HMI_A_20140307.dtl HMI_A_20140308.dtl... 5. Added the [Add BOM (Byte Order Mark) to file header for EXCEL can interpreting non-ascii strings correctly.] check box in Backup object settings dialog box. CSV files that contain non-ascii characters can still be opened directly by Excel. 6. Added Tag Manager that allows selecting the Siemens S7-1200 PLC tags to be imported.

As shown in the following figure, in [QArea] only three tags: [Q00], [Q01], and [Q02] are imported. Therefore, only these three tags can be selected in object settings. 7. When exporting user-defined word tags into CSV file or EXCEL file, the data type of the tags will also be exported, in order to keep the data type consistent when re-imported. As shown in the following figure, the data type information is included in the CSV file or EXCEL file. 8. Added Data Security feature. This feature allows setting restrictions on the write operations that modify local register data. In [System Parameter Settings] select [Local HMI] and then click [Security ] button. Data Security protects local Bit addresses (LB, LW_Bit, RW_Bit, RW_A_Bit, RBI) and local Word addresses (LW, RW, RW_A, RWI, EM).

The restrictions include [Set ON only], [Set OFF only] for Bit addresses, and a range between the specified [Min. value] and [Max. value] for Word addresses. [Disable remote-write operation]: If selected, the remote HMI will not be able to write to the protected address. [Used only in remote-write operation]: If selected, the specified condition is only used to restrict the write operation by a remote device. The local write operation is not restricted.

[Use min. / max. value when write value is less / more than min. / max. value]: If not selected, when the written value is not within the specified range, the system will keep the original value. If selected, when the written value is not within the specified range, the system will write the min. / max. value instead. [Notification]: When the written value is not within the specified range, the system will trigger the designated notification bit address ON / OFF. In the example of setting Data Security on a Bit address as shown in the preceding figure, the remote HMI can only set ON LB-10, while the local HMI is not restricted. If the remote HMI attempts to set LB-10 OFF, the system will trigger notification bit LB-0 ON. 9. Label Tag Library supports the.xlsx file format of EXCEL 2007 or later versions.

10. Supports setting DPI information to prevent error in text display that occurs when opening the same project file on different PC. The project files created with earlier EasyBuilder do not contain DPI information; therefore, when opening the same project file on different PC, the texts may be incorrectly displayed due to the difference in DPI settings. On EasyBuilder Pro toolbar, click [Tools]» [Text DPI Setting] to open the following dialog box and set DPI. The DPI setting is stored in the project file to prevent incorrect display. 11. Supports directly pasting a picture from the clipboard into Picture Library.

12. Added [Paste (Add Mode)] in Event Log settings dialog box. [Paste (Add Mode)]: Appends as a new entry. [Paste]: Overwrites the selected item with the new items. A message window will pop up to confirm this operation. 13. Added [Multi. Copy] selection to the right-click menu. 14. Added a Japanese font: Meiryo. 15. When changing static HMI IP address to DHCP, the data in system registers from LW-9129 to LW-9123 (HMI ethernet IP) will also be updated. 16. Combined [Numeric Input] and [Numeric Display] objects into [Numeric Object]. The way to set a Numeric object is the same as Numeric Display object. To enable the Numeric Input features, please select [Allow input] check box. This new feature allows easier switching between [Numeric Input] and [Numeric Display] objects, and no repeated settings are required.

17. Combined [ASCII Input] and [ASCII Display] objects into ASCII object. The way to set an ASCII object is the same as ASCII Display object. To enable the ASCII Input features, please select [Allow input] check box. This new feature allows easier switching between ASCII Input and ASCII Display objects, and no repeated settings are required. 18. When using an array tag for the PLC, an index register can be designated. The PLC drivers that support this feature include: OMRON EtherNet/IP (NJ Series) driver, Rockwell EtherNet/IP (CompactLogix) Free Tag Names driver, etc. 19. Added Droid Sans Fallback font file which supports Unicode characters: Traditional Chinese, Simplified Chinese, Korean, and Japanese. When the font that will be displayed on HMI is unknown, this font file can be used. The time needed for downloading the project file may be longer. 20. Added AZERTY USB Keyboard. The system register [LW-9199: (16bit): keyboard

layout: 0 (QWERTY), 1 (AZERTY)] can be used to switch between QWERTY and AZERTY keyboards. 21. Changed the way to display object ID: A. The object ID in Common Window and Underlay Window will not be displayed in Base Window. B. All object ID of the overlapped objects will be placed on the top layer.

Corrections EasyBuilder Pro V4.10.02 1. Fixed the problem where [Preservation limit] mode of Event Log cannot correctly delete the history files that are not within the specified number of preceding days. 2. Fixed the problem where Circular Trend Display cannot draw a full circle. 3. Fixed the problem where Arabic / Turkish text cannot be correctly displayed. 4. Fixed the problem where Event Log management has no effect on new events. 5. Fixed the problem where the transparent PNG graphics cannot be correctly displayed. 6. Fixed the problem where HMI cannot be restarted when connection is by a USB cable. 7. Fixed the problem where JOG++ and JOG-- modes do not continue to increment/decrement with Set Word object. 8. Fixed the problem where the values of system register [LB-12092: enable VNC (set ON), disable VNC (set OFF)] cannot be correctly stored. 9. Fixed the problem where the system register [LB-9080 (16bit): backlight saver time (unit: minute)] is incorrectly initialized. 10. Fixed the problem where an error occurs when placing an array of Boolean data type in the IF condition statement and using a variable as the array index. 11. Fixed the problem where PLW address cannot be selected when programming cmt-svr objects in Chinese version of EasyBuilder Pro. 12. Fixed the problem where the fonts in Event Display object may not be correctly displayed if only a part but not all the languages are selected during

compilation. 13. Fixed the problem where data cannot be transferred to GE Fanuc SNP-X device at normal speed when using Macro or Data Transfer object. 14. Fixed the problem where the number of states is incorrect when pressing a Multi-State Switch object that is set to [User-defined mapping]» [Jump to error state]. 15. Fixed the problem when using MODBUS TCP/IP Gateway, the system register LW-9288 does not show error code if HMI is disconnected with PLC. 16. Fixed the problem where the text at the end of a recipe name is the same as the recipe s item name, the RecipeQuery function in Macro cannot be compiled.

Drivers 1. Free Protocol Server(Ethernet) driver supports UDP (User Datagram Protocol). 2. Modbus Server driver supports the Modbus test specification of Mainland China: GB/T 25919.1-2010 and GB/T 58919.2-2010. 3. DELTA DVP driver supports [Multiple Coils Writing] feature that improves the speed of execution of Macro. 4. Fixed the problem where communication with PLC stops after a long time of operation when using Siemens S7-200 PPI driver. 5. Fixed the incorrect DBnBit address type in Siemens S7-300 (ISO Ethernet) driver. 6. The CONNECT_STATUS address is added in Barcode/Keyboard(USB/COM) driver for indicating the connection status of USB Barcode device. 7. VIGOR driver supports Pass-Through feature. 8. LS XBM/XBC Cnet device types R and R_Bit are added. 9. Panasonic MINAS A5 driver supports RS485 communication. 10. Fixed the problem where the array length is not maintained when using Tag Editor of OMRON EtherNet/IP (NJ Series) driver to edit an array tag. 11. Fixed the problem where Macro cannot select SINT tag of Rockwell Free Tag Names drivers. 12. Hollysys LE/LM PLC driver is added. 13. IAI PCON-C-42PI driver is added. 14. HeFei ShenNong Motor driver is added.