EElectronic Devices and Systems. EK-87 Electronic Volume Corrector. This product is discontinued!

Similar documents
EC 600 Electronic Volume Corrector

Compact Gas Volume Corrector System EC 900 珠海司福斯特科技有限公司 PRODUCT INFORMATION. Serving the Gas Industry Worldwide

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

MID approval no. DE-08-MI004-PTB004 Date of release

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Intrinsically Safe Barriers

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

PI-EX-ME-2NAM/COC-24VDC

Digital Positioner 8049

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

Series 3730 Type Electropneumatic Positioner

PI-EX-ME-2NAM/COC-120VAC

Flow Measurement SITRANS F C

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

PHOENIX CONTACT - 12/2007

Online data sheet. Flow-X FLOW COMPUTER

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

Series 3730 Electropneumatic Positioner Type

5 Fieldbus Technology

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

Operating instructions. Standstill monitor A / / 2011

Temperature Switches

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

Intrinsically safe batch controller Batching Master 110i

Isolating repeater IRU 420

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information

Safety instructions Overvoltage protection B81-35

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

SideControl Positioner

Diaphragm gas meters with Absolute ENCODER

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Dräger Polytron 8200 Stationary gas detector (CatEx)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

HERION SERIES Indirect solenoid actuated spool valves

Technical Information Promonitor NRF560

Interface and Supply module. IPC 3x0i / PSC 3x0i

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Gas Controller System DGC-06

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

AB Axis Industries. Use

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

General Specifications

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

This explosion proof Pulse Generator is equipped with an inductive sensor for use in

PROFIBUS-PA Positioner Type 3785

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

Electronic SD1, AS 8, ASR 14, ASR 20

TEPI11 P/I signal converter

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values

M-Bus Central Unit. Use

Operating Instructions

APPLICATION GUIDE. Interface Modules IM Series.

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

Compact Universal Controllers

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Indicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters

C-Flow Coriolis Mass Flow Meter

Process Analysis Systems. Stratos Pro A4 MSPH/MSPH. Chem Energy Pharm Food Water. Connection

Signal conditioning instruments VEGASCAN 693. Product Information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

Cerabar S PMC71, PMP71, PMP ma HART, PROFIBUS PA, FOUNDATION Fieldbus

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7

DS 96/48 PK. Digital indicator. Manual 42/33-90 EN Rev. 00 DIM

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

Supplementary Components WirelessHART products

DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

D-R300 / D-R320 / D-R 800 DATASHEET

LB Remote I/O. CEAG Sicherheitstechnik GmbH 256

Thermal Mass Flow Meters and Controllers for Gases with IP67 & Ex Protection

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

HYGROPHIL-F, Moisture Analyzer, Type , -11, -12, -13 series A

Sensor for car parks and tunnels

VC211L ELECTRONIC VOLUME CORRECTOR.

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Transcription:

EElectronic Devices and Systems EK-87 Electronic Volume Corrector This product is discontinued!

In brief EK-87 electronic volume corrector System volume corrector including integrated data storage device for collecting performance data Data storage for billing purposes For use with all gas meters with low or highfrequency volume pulsers High accuracy Easy to use DSfG compatible PTB approval for custody transfer The new EK-87 has been designed for gas metering systems which require the highest metering accuracy and functionability while at the same time being easy to operate. Such systems can be found in gas substations belonging to gas transport companies as well as in metering plants for end-users. The EK-87 is a DSfG-compatible volume corrector for use with natural gases and which includes a built-in data storage device for the long-term registration of actual volumes, standard volumes and mean values of pressure and temperature. It has a modular design and is available in two different housings: EK-87/S in a 19 slide-in cassette for installation in a cabinet EK-87/A has a housing for wall mounting DSfG: Digital interface for gas metering device

Product features Hardware control panel with display, keyboard, calibration switch and serial interface mains sockets for 230 VAC and 24 VDC supply voltage two pulse inputs for high and lowfrequency signals, intrinsically safe one input for a pressure sensor, 2-wire system, intrinsically safe one resistance input for Pt-100 temperature sensor, 4-wire system, intrinsically safe one relay output four transistor outputs, of which two can be officially sealed if required Software functions calculation of compressibility factor according to SGERG-88 or AGA-NX- 19... or as a constant calculation of flow rate with limit monitoring and storage of minimum and maximum values electronic logbook for over 200 entries freeze function for two sets of measurement data including the possibility of showing the differences between the two remote control of the gas analysis data for the calculation of the compressibility via the DSfG interface, logbook for the changes concerning the gas analysis data 4-channel data storage function (DS-100) Sensors Rosemount 2088 A or 3051 CA pressure sensor (up to 120 bar) Pt-100 temperature sensor, 4-wire system in various versions with lengths of up to 250 mm Additional equipment (optional) AA2 analog output card, 2 channels, 0/4... 20 ma S1M modem connection (second serial interface, for use as an alternative to the interface on the front panel) for EK-87/S plug-in connection at the back for EK-87/A socket in the connection box DSfG interface DCF-77 radio-controlled clock (only for use as an alternative to the DSfG interface card) Operation All of the measurement values and data, with the exception of the individual interval values in the data storage function, can be called up via the control panel. The most important values and functions are accessible directly via the keys whereas all other values are ordered in a list and can be selected by using the cursor keys. The information is then displayed with a clear indication of the value and the unit of measurement. By using the Help function, additional clarifying information can be displayed in text form. In the case of a fault in the device or in the metering system, the EK-87 offers various troubleshooting possibilities. As well as the status register, which keeps a record of all error messages until they have been rectified, a separate list of rectified errors and an operating logbook are also available. The list of rectified errors contains all error messages including date and time in the order in which they have been rectified. The logbook has a chronological list of alarms, warnings and instructions. In order to monitor the accuracy during operation, an extensive freeze function is available. By keying-in the time or a test volume, the actual values can easily be determined.

Functional details System integration illuminated display, 2x16 characters calibration switch C / b status display, LEDs for power, warning and alarm messages keypad serial interface Inputs The EK-87 can be connected to any gas meter which is fitted with one or two pulsers. It processes both low and high-frequency pulse signals from potential-free pulsers or NAMUR pulsers. All pressure and temperature sensors can be used either in an intrinsically safe version or in a flameproof enclosure. To conform with the requirements concerning explosion protection, both must be of the same type (EEx-i or EEx-d). Outputs The digital and analog outputs can be assigned as required. For the pulse output, it is possible to choose between actual and standard volume. If a digital output is used as a switch output, it is possible to choose between alarm, warning or monitoring a specific message, e.g. calibration switch open. The limit control function for the interval and daily counters in the DS-100 function can also be used as a specific message. Programming a time synchronizing output is a further possibility. Two of the transistor outputs can be officially sealed. They can be accessed via a separate socket. The values for standard flow, actual flow, pressure, temperature, can be assigned to the analog outputs if the appropriate card is installed. Digital interface for gas metering devices (DSfG) The DSfG interface enables the connection of the EK-87 to the DSfG-Bus. This interface is based on the DVGW worksheet G 485 and is used to call up meter readings and metering data for further processing in DSfG-compatible devices. The data concerning the characteristics of the gas, which is used for the calculation of the compressibility factor, can also be changed via the DSfG interface. Every change is registered in a special logbook so that a record of the changes can be seen at a later date. RS 232/ V.24 serial interface As a standard feature, the EK-87 is equipped with a serial interface, which is located on the front panel. Using this interface, the integrated data storage function can be operated and the data for the volume corrector can be programmed or called up. If a fixed connection to a data transfer device is required, an alternative connection, the S1M modem interface, can be made available at the back of the device (EK-87/S) or at the bottom of the connection box (EK-87/A). DCF-77 radio-controlled clock If no DSfG interface card is installed, an interface card connected to an external DCF-77 receiver can be installed in the device for the purposes of synchronizing the time.

Two pulse input two reserve inputs Mains connection 24 V DC; 12 W 230 V AC; 15 VA Pressure sensor input for Pt-100 Second serial interface One relay output Four transistor outputs Two analog outputs DSfG serial interface or DCF 77 card Data storage device A standard feature of the EK-87 is the data storage device (DS-100), which stores standard and actual volumes as well as the mean values for pressure and temperature for a given period of time. It has sufficient capacity to record data for up to 6 months when using a time interval of 60 minutes. In addition, the meter readings used for billing purposes at the beginning of the month are also stored. The stored data can be read out by means of a mobile readout device, a portable PC or remote data transfer and then further processed in the Elster LIS-100 data collection system. Ordering In order to process your order as quickly as possible, the following information is required: version of the device: EK-87/S or EK-87/A pressure sensor: version and pressure range temperature sensor: version EBL... (length) additional equipment: analog output card, DSfG interface, DCF receiver, additional serial interface accessories EK-87/S EK-87/A Accessories 19 mounting frame (for up to 2 EK-87/S models) front cover plate for the frame temperature sensor thermowell in various versions three-way test valve base plate for pressure sensor connection cables uninterrupted power supply systems

Engineering Technical data Version EK-87/A EK-87/S Housing wall housing with separate 19 slide-in cassette protected connection box (42 TE, 3 HE) Dimensions (mm) W 310 x H 223 x D 280 W 213 x H 128.5 x D228,5 Weight approx. 2.5 kg approx. 2.5 kg protections class IP 54 IP 20 Ambient temperature -10 C to + 50 C 0 C to + 40 C Power supply 230 V AC, 15 VA or 24 V DC, 12 W, backup battery for storing data in the event of a power failure Pulse inputs Version according to NAMUR, monitors cable faults, voltage level and card failure Number: 2 Max. frequency: 3000 Hz no-load voltage: 8 V ± 5 % short-circuit current: 8 ma ± 5 % switch threshold on : 2.1 ma ± 5 % switch threshold off : 1.2 ma ± 5 % Analog input for pressure sensor 4-20 ma, two-wire system no-load voltage: 17,5 V ± 10 % short-circuit current: max. 24 ma resistance load: 270 Ω Pt-100 input four-wire system no-load voltage: max. 8 V ( I+, I- ) short-circuit current: 0.4 ma ± 1 % Digital/pulse outputs 1 relay two-way contact voltage U max : 250 V current I max : 2 A contact rating P max : 60 W, 125 VA remaining current: max. 0,02 ma maximum frequency: 1 Hz 4 transistor outputs voltage U max : 28.8 V current I max : 50 ma voltage drop: < 1.8 V at 50 ma remaining current: < 0.5 ma at 28.8V maximum frequency: 10 Hz galvanic separation: from the system and from each other Analog outputs 2 outputs: 0/4 20 ma maximum load: 600 Ω Error: < 0.25 % of measured value galvanic separation: from the system and from each other with common ground Data interface RS 232C / V.24 input voltage: input level 1 : input level 0 : baud rate: < 30 V 3 V 0 V 4800 baud Explosion protection for meter and measurement inputs Pulses Pressure Temperature Mark [ EEx ib ] IIC Approval BVS 92.C.2039X BVS 92.C.2046X Limits U 0 < 11.6 V < 20 V < 9.6 V I n < 11.8 ma < 75 ma < 3 ma L < 10 mh < 0.5 mh < 10 mh C < 300 nf < 200 nf < 400 nf

Pressure sensors Version Rosemount 2088 A Rosemount 3051 CA Type absolute-pressure sensor, 2-wire system Pressure range - for custody transfer up to 50 bar absolute up to 120 bar absolute - no official measurements up to 120 bar absolute up to 120 bar absolute Standard measuring ranges 0.6..1.9 0.9..4.5 ( bar absolute ) 0.9..4.5 2.0..10 2.0..10 3.0..15 3.0..15 4.0..20 4.0..20 6.0..30 10.0..50 10.0..50 14.0..70 20.0..100 Measuring ratio p max : p min 5 : 1 und 2,4 : 1 for custody tranfer Further measuring ranges as required within measuring ratio Measuring error (at 20 C) < ± 0.3 % of measured value < ± 0.2 % of measured value Measuring error (at -10 C.. 40 C) < ± 0.5 % of measured value < ± 0.3 % of measured value Explosion protection stamp intrinsically safe EEx-ia IIC T4/T5, alternatively flameproof enclosure EEx-d IIC T5/T6 Weight approx. 0,9 kg approx. 2,5 kg Process connection tapping screw for 6 mm pipe (Ermeto) Electric connection screw clip, lead 1 2 NPT Connection cable total diameter 8-10 mm, (2 wires and screen) 2 x 1,5 mm 2 or 2 x 2 x 0,75 mm 2 for intrinsically safe circuit light blue sheath Ambient temperature range -40 C to +85 C; for custody transfer: -10 C to +40 C Rosemount 2088 A Rosemount 3051 CA Further approved pressure sensors for custody transfer: Rosemount AP/GP 1151, Druck PTX-610 Temperature Sensors Version EBL... 50AF/EX-I 160AF/EX-I 250AF/EX-I 140AD/EX-I 160AF/EX-D 250AF/EX-D 160AD/EX-D Type Pt-100 1/3 DIN class B Gas temperature range -10 C.. +60 C ( for custody transfer ) Measuring error < ± 0.1 % of measured value Length ( installation ) 88 mm 160 mm 250 mm 140 mm 160 mm 250 mm 160 mm Diameter of sensor 4 mm 6 mm 6 mm 8 mm 6 mm 6 mm 11 mm Process connection 8 mm G1/2" G1/2" G3/4" G1/2" G1/2" G3/4" plug-in syst. For Elster thermowell EBL 45, 50, EBL 160 EBL 250 in Medium EBL 160 EBL 250 in Medium 58,67 at 16 bar at 100 bar Explosion protect. stamp intrinsically safe EEx-ia IIC T4/T5/T6 flameproof enclosure EEx-d IIC T6 Electrical connection screw clips Lead PG 9 according to EN 50018 Connecting cable total diameter 6.5-9 mm total diameter 8-10 mm (4 wires and screen) e. g. 2 x 2 x 0,75 mm 2, color light blue e. g. 4 x 1,5 mm 2 EBL 160 AF / EX-I EBL 250 AF / EX-I EBL 140 AD / EX-I EBL 50 AF/EX-I EBL 160 AF/EX-D EBL 250 AF/EX-D EBL 160 AD/EX-D

Electronic devices and systems Volume correctors with integrated DS-100 data storage function EK-88/K EK-87 mountable onto a gas meter or on a wall, calculation of compressibility factor in accordance with AGA-NX-19, battery powered for wall mounting or integrating into a 19 cabinet (two EK-87/S per cabinet), calculation of compressibility in accordance with S-GERG-88 or AGA-NX-19, alternative power supply 230 V AC or 24 V DC Electronic volume correctors which can be equipped with an optional data storage function in accordance with the DSfG specifications GAS-MAX 19 cabinet device, calculation of compressibility factor in accordance with S-GERG-88 or AGA-NX-19, alternative power supply 230 V AC or 24 V DC GAS-MAX/E 19 cabinet device, calculation of compressibility factor in accordance with S-GERG-88 or AGA-NX-19 by using actual gas characteristics measured by a gas chromatograph, alternative power supply 230 V AC or 24 V DC Temperature corrector TC-90/T mountable directly onto a thermowell or on a wall, battery powered Long-term pulse collecting system LIS-100 DS-100 data storing devices in various versions AS-200 mobile readout device EM-100 industrial modem DKM-100 software-controlled switching device for up to four Elster electronic devices, with built-in modem Software packages for LIS-100 DAS-100 data readout software for direct reading of data AWS-100 evaluation software for displaying, printing and transferring data LSM-100 control center for remote data transfer via modem Registration and control devices GAS-ASS/R registration device GAS-ASS automatic station control device A market-oriented product range The Elster Group offers a market-oriented product range in the field of measurement and control as well as data communication. The range of products for gas measurement covers diaphragm gas meters for industrial, commercial and domestic purposes, turbine gas meters, quantometers and test gas meters. Meter regulators, domestic regulators and other regulating devices for low, medium and high pressures make up the supply program in the field of gas pressure and control. Elster can claim more than 500 years of know-how in the development and production of such devices and this provides the foundation for innovation, quality, competence and safety. For further information, please do not hesitate to get in touch with us. Europe: Elster Handel GmbH Steinernstrasse 19-21, D-55252 Mainz-Kastel, Germany Phone +49 ( 0) 6134 / 605-0 Fax +49 ( 0) 6134 / 605-390 North America: American Meter Company 300 Welsh Road, Building One, Horsham, PA 19044-2234 USA Phone +1 215-830-18 57 Fax +1 215-830-18 95 All Other Countries: International Gas Measurement Ltd. Tuscany Way, Blackbushe Business Park, Yateley, Hampshire GU 46 6 GF England Phone +44(0)1252-302035 Fax +44(0)1252-302037 Valid from: February 97 Subject to change 2 / 97 Be 3.0 9020 PP EN 01