48V 1.5KW 1U AC-DC Power Supply Electrical Specification for: Telkoor Model: 0/ 7 SHEET 1 OF 1

Similar documents
Electrical Specification for: 48V 1.5KW 1U AC-DC Power Supply. Digital Power Model: PS-1548 REV SHEET 1 OF 5

48V 2KW 1U AC-DC Power Supply PS Electrical Specification for: Telkoor Model:

Electrical Specification for: efo Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: CUSTOMER SIZE CAGE CO

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

CPCI - 6U - AC - 600W

CPCI - 6U - DC - 350W

REVISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 13/12/08 Specification Release 13/12/08 S. Sadot A1 13/02/09

PS-1142 MicroTCA 1000W Power Module

(877) CPCI-3U Series. Input Voltage Range AC Input. Input Voltage Range 48VDC Input. Input Voltage Range 24/28VDC Input

The APR YE meets UL/CSA and all international safety requirements. It is SELV. Min Typ Max 90

SFP450-12BG AC-DC Front-End Data Sheet 12V Output, 450 Watts

(877) CPCI-6U Series. Input Voltage Range AC Input. Input Voltage Range 48VDC Input. Input Voltage Range 24/28VDC Input

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems

The ATF YE meets UL/CSA and all international safety requirements. CE mark is pending. Min Typ Max

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

A0750 AC-DC POWER MODULE

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

Universal Power Supplies

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00

D1U-W Hx Series

CAN enabled The retifier can be monitored and controlled through analogue signals. It is also equipped with a CAN signal bus.

CPS Industrial Power Supply

5 x 8.5 x 1.61 Inch Form Factor. Convection Cooling Rated. Approved to EN Dual Fusing. Current Sharing. Open Frame. Peak Power Capability

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

60 Watt Medical (MWLT)

Safety Standards. Model Number: Unit Weight:

PRODUCT SPECIFICATION File: EA-A0601HE-12 Model: SSA-0601HE-12 Date: Apr. 17, 2015

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 90% at 90V AC)

CompactPCI SYSTEM POWER SUPPLIES. CPCI SERIES 150 to 350 Watts, Ac Input with PFC DPCI SERIES 150 to 350 Watts, 48 Vdc Input FEATURES:

12-15VDC (12V±5%) 24-28VDC (24V±5%)

D1U-W Hx Series

PRODUCT SPECIFICATION File:SSA Model : SSA Rev:A2 Date: Nov. 29, 2010

ATX-3000 Product Specification Enhance Electronics Co.,LTD

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

D1U4CS-W HxxC Series AC/DC Front End Power Supply

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

PDD-300 pulsed diode driver

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

500Watts Medical Single Output

ENGINEERING SPECIFICATION SHEET SPEC. Revision History

SPECIFICATIONS. Input Output Agency Approvals 0 ~ 62.5A. toll-free (603)

ENGINEERING SPECIFICATION SHEET. Table of Contents 1 SCOPE ELECTRICAL SPECIFICATION...5

Safety Standards. Model Number

SPECIFICATIONS: PSAK650

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

-AC Input- Voltage/Current...AC V, 47-63Hz, 5.5A Max, 1 Phase. Fusing...AC 6.3A, 250V internal line fuse provided, non-user serviceable. Power F

12-15VDC (12V±5%) 24-28VDC (24V±5%)

SPECIFICATION. Model: PS3038. Redundant Power Supply With Active PFC 700W + 700W

RT4F-110V/25A RECTIFIER

CAR0548TN. Product Features. Benefits. -48V/ 500W rectifier

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

TFX PC Power Specifications

Constant Voltage Mode

CVN300-96P01A SERIES. Five Output. Special Features

SST-NJ450-SXL. Nightjar Series. The definitive small form factor fanless power supply

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

RT12-240V/2.4kW Rectifier Specification

Safety Standards. Model Number:

Watts. xppower.com. General. Input. Output. Environmental. EMC & Safety. Compact Size. IT & Medical Approvals.

CINT W Triple Output Industrial Series

GSP750 Series. 750 Watts. AC-DC Power Supplies. Models & Ratings. Input

Safety Standards. Model Number:

SPECIFICATION. SFX Form Factor. SST-ST45SF 450W Switching Power Supply Active PFC Circuit Full Range Input. SFX Form Factor

Safety Standards. Model Number:

Safety Standards. Model Number:

HAL1500 SERIES WATTS, SINGLE OUTPUT w/standby

Series MPM-815H 150W PFC MEDICAL ATX POWER SUPPLY

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Safety Standards. Model Number:

ENGINEERING SPECIFICATION. 40W AC Adaptor. Part Number: PA W1

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1AZ

Safety Standards. Model Number:

275 Watt Medical Ultra low profile

CINT W Single Output Industrial Series

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

CSPS-6K (Shelf Type) POWER you need POWER SHELF

Output Voltage* (nom.)(adjustable)

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

RT4B-110V/12A RECTIFIER

RT4F-48V/50A-WAC RECTIFIER

RT4F-120V/20A-WAC RECTIFIER

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

C1U-W Tx Series

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0

Safety Standards. Model Number:

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

ORDERING INFORMATION SEE PAGE 6

C1U-W Tx Series AC/DC Front End Power Supply

IS-900R2UPD8G. Redundant Power Supply. Active PFC 900W + 900W. 80+ Gold Efficiency SPECIFICATION. Revision: 1.0

Safety Standards. Model Number:

AEA400S-4 Power Supply Product Specification. An APM Electronics USA, Inc. 400W Power Supply Specification For Standard PS2 Mini Redundant PSU

Transcription:

Electrical Specification for: 48V 1.5KW 1U AC-DC Power Supply Telkoor Model: 900-1548-0000 0/ 7 SHEET 1 OF 1

REVISION HISTORY Rev Level A B Rev Date Change Made Reason for Change Effective Approved 22/06 0/ 7 Release for production Release for production 22/06 0/ 7 S.Sadot 29/09/09 Update out line drawing page# 6. Update front panel view 29/09/09 G. Sela By Approvals Name Date Written by: S. Sadot 22/06 200/ 7 Engineering: S. Sadot 22/06 200/ 7 Marketing: B. Weiss 22/06/2007 Management: Y. Ben-Ami 25/06/2007 0/ 7 SHEET 2 OF 2

Input: Input Voltage: Frequency: Inrush Current: Power Factor: Efficiency Input Protection: Brown Out: 90-264Vac, auto range, single phase 47-63Hz 50 A maximum, 0.98 typical at 230Vac, full load 0.99 typical at 115Vac, full load >89% at 230Vac, full load rated power >83% at 115Vac, full load rated power Internal Line Fuse: IEC type, 3AG, 16A 250Vac NORMAL ACTION 75 to 300Vac for 50Msec Output Voltages & Currents: Input Range V1 Output I Min. Voltage Load I Max. Load Peak Load V Aux. (*Note 1) 90Vac 140Vac 48V 0 25A 28A 5V/30mA + or 3.3V/30mA + 180Vc 264Vac 48V 0 32A 35A 5V/30mA + or 3.3V/30mA + (*) Note: Total power 150mW Floating Output Power: Line Regulation: Load Regulation: Ripple & Noise V1: Output Voltage Adjustment Range 5% Initial Set Point Tolerance: Overshoot & Undershoot: Transient Load Response: Turn On Delay: Hold-up Time: Turn-On Rise Time: Over-current Protection: Over-voltage Protection: Temperature Protection: Remote Sense on V1 Current Share 1.5KW for 48V 1200W for 24V models. 800W for 12V model. 0.4% for Vin (Min) to Vin (Max). 0.5% for load changes from zero to full load. 1% p-p Max @ 20 MHz bandwidth with 1u ceramic and 10 electrolytic on measure point. 250mV Less than 1% at turn ON-OFF 3% Max. deviation for load change of 50% to 100%, at slew rate of 1A/usec, recovery time less then 1mSec 2 sec. Maximum. 16mSec minimum 60mSec Max. 105 to 120% of IMax, constant current limit, automatic recovery, when cause of overload or short is removed Shut down at 110 130% of nominal output, AC input must recycled to restart. Shutdown due to excessive ambient temperature at over heating or malfunction of cooling fans. The sense point is at 90 C for the internal heat signal, unit recovers automatically typical hysterisis 30 C. 600mV Max voltage compensation for cable losses with respect to the main output N+1 Redundancy. Hot Swap Internal O-Ring diode (FET) 0/ 7 SHEET 3 OF 3

Signals & Commands Important note: All signals and commands refer to +5V Aux RTN. (See attached pin assignment table) Inhibit: Enable: PS Alarm: AC OK: Fan Fail: I²C (IPMI interface) - OPTION Visual Indicators AC In Range Output In Range Hot swap indication Environmental Specifications: Temperature: Temperature Coefficient: Cooling: Humidity: Altitude: Vibration: Active low, main outputs shut down to zero. Only auxiliary output exists at this point. Contact closure to external ground to start unit. On shortest unit. On shortest pin (last make, first break) Open collector active low when the output drops 10% below nominal. Open Collector Active low when AC in range. TTL Compatible signal, normally High, goes low when fan fail. Internal I²C/IPMI interface Card Green LED illuminates for AC O.K Green LED illuminates for V1 output in range. Blue LED illuminates in accordance with ATCA standard for hot swap indications (see Hot swap indication Table) Operating: -10 C to +50 C (de-rating linearly to 70 C with 50% de-rating). Storage: -40 C to +85 C. 0 to 70 C 0.02%/ C Forced air by internal two fans - Front to back 5% to 95% RH non-condensation. Operating 10,000 ft. Non- operating 40,000 ft. Three orthogonal axes at 1 octave/min, 5 min dwell at four major resonances at 0.75G peak, 5Hz to 500Hz. Safety Regulatory & EMC Specifications (Designed to meet): MEETS FCC CLASS B, CISPR 22 CLASS B, EN55022 CLASS B with an external TBD line filter EN61000-3-2 EN61000-3-3 EN6000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 HARMONICS VOLTAGE FLUCTUATION ESD +8KV AIR +4KV CONTACT DISCHARGE, performance criteria B RADIATED IMMUNITY: 80-1000Mhz 3V/m, AM 80% (1KHz), criteria A FAST TRANSIENT: 1KV for AC power port, 0.5KV for DC power I/O and signals Port, performance criteria B SURGE: 2KV common mode and 1KV differential mode 3VRMS, 80% A.M. BY 1kHz EN61000-4-8 3A /m at 50Hz, performance criteria A. EN61000-11 VOLTAGE Dips and interruption: 30% reduction for 10mSec Criteria B, 60% For 100mSec. Criteria C, 95% reduction for 5000mSec Criteria C. Dielectric Withstand: Input to Case: Input to Output: Output to Case: 1500VAC. 3000VAC 1500VDC 0/ 7 SHEET 4 OF 4

Safety Agency Compliance: UL 60950, EN 60950, IEC 60950 Leakage Current: MTBF: CSA C22.2-234, LEVEL 3. CE MARK 2200VDC 2mA @50/60 Hz, 264Vac input. 300,000 hours minimum per BELCOR 332,issue 6 specification @30 degrees C Mechanical Dimensions Size Weight I/O Connector 1U H X 114 W X 278 L mm 1.6Kg Positronic Right Angle PCI47M400A1 Status Steady Blue Blinking blue Off ATCA Hot Swap indication Table (BLUE LED on Front Panel) Definition P.S. powering up or ready for ex-traction P.S. hot swap process P.S. operating 0/ 7 SHEET 5 OF 5

Power Box Outline Drawing Power Box Pin Assignment 0/ 7 SHEET 6 OF 6

Power Box Pin Assignment Pin # Signal Name Remarks 1-6 -48V 48V Floating 7-12 -48V RTN 48V Floating 13 HA0 Pull up resistor will be in the PS card 14 HA1 Pull up resistor will be in the PS card 15 HA2 Pull up resistor will be in the PS card 16 HA3 Pull up resistor will be in the PS card 17 HA4 Pull up resistor will be in the PS card 18 HA5 Pull up resistor will be in the PS card 19 HA6 Pull up resistor will be in the PS card 20 HA7 Pull up resistor will be in the PS card 21 5V_GND 22 SCL_A I2C bus A 23 SDA_A I2C bus A 24 SCL_B I2C bus B 25 SDA_B I2C bus B 26 5V_GND 27 EN Enable Connect to GND to start the unit. On shortest pin. 28 5V_GND 29 GA0 Geographic Address Bit 0 30 GA1 Geographic Address Bit 1 31 GA2 Geographic Address Bit 2 32 5V_Standby +3.3V 20mA Auxiliary Output 33 FAN_FAIL Open Collector Active High 34 PS_INT 35 PS_ALARM Open Collector which contain all alarms + Hot swap switch. Pull up resistor will be on the Carrier card. 36 AC_OK Open Collector Active High, indicates input line 37 INHIBIT Power Supply ON/OFF switch connect to GND. 38 CURRENT SHARE Single Wire N+1 up to 6 unit In Parallel 39 N-Sense -48V Remote Sense 40 P-Sense -48V RTN Remote Sense 41 3.3V 42 5V_GND 43 PTC_AdJ Option For External Temperature Sensor 44 5V_PTC Option For External Temperature Sensor 45 F_GND Chassis Ground 46 PHASE AC Supply 47 Neutral AC Supply 0/ 7 SHEET 7 OF 7