HP9115C HP9315C Series High Frequency Online UPS 1-20KVA(1 Ph in/1ph out & 3 Ph in/1ph out) Personal Computers Network Industry Medical Telecom Local area Networks Security Product snapshot: Model: HP9115C 1-10KVA (1Ph in/1ph out) Model: HP9315C 10-20KVA (3Ph in/1ph out) Nominal voltage: 208/220/230/240VAC (1-20KVA) Nominal voltage: 380/400/415VAC (10-20KVA) Nominal frequency: 50/60Hz Output Power factor: 0.8/0.9(Optional) Stable and Reliable,Comprehensive Protection : HP9115C/HP9315C 1-20KVA adopts the double conversion online architecture ideal for resolving all issues on power supply. This state-of-the-art solution is especially designed for eliminating the power loss, extra high or low voltage of utility power, voltage sags or damped oscillation, high-voltage pulse, voltage fluctuation, surge voltage, harmonic distortion,clutter immunity, and frequency fluctuation etc., delivery safely and reliable power supply to guarantee for user's load. 25 www.soropower.com
Key Features: Its cut-edge digital technology of DSP (Digital S i g n a l Processor), can greatly improve the products p e r formance and system reliability, and deliver a compact i n tegration w i th h i g h e r power density ; Output power factor up to 0.8 - applicable to the tendency of future load evolution, and d e l i v e r h i g h e r p a y l o a d capacity; Total power factor up to 90% can minimize the power loss of UPS and save utilization cost for user; Emergency Power Off (EPO): UPS can be instantly shut off in case of any emergency; Compliance with EMC requirements of IEC61000-4, provide your device a clean electric environment. Active power factor correction (PFC) technology a l l o w s t h e i n p u t p o w e r f a c t o r a p p r o a c h i n g t o 1, dramatically reducing the immunity on utility grid; Excellent input frequency range makes UPS suitable to different power supply devices, i.e. generator set; Parallel Kit: realize the parallel extension and redundancy function, offer more flexibility and safety for user's power supply planning; Compact Design, Lower Noise; can automatically select the optimal charge mode as per the battery type and conditions, thus further maximizing the l i fespan o f b a ttery b a n k. In a d d i tion, the system can periodically conduct the charge & discharge management for the battery bank. User also can select the battery voltage (192V or 240V) on demands; The user can query and set the proper UPS control parameters for intelligent UPS management;automatically identify and adapt to 50/60Hz power supply system, fulfilling the requirements in various power supply systems; Perfect failure protection and alarm function: provide complete failure protection and clear alarm notification function in case of I/O over-voltage or under-voltage, battery overcharge or under-voltage, overload, and short circuit. Rich Communication and Monitoring Features: Provide RS232 USB interface and communication cable for local or remote power supply management; User-friendly interface : LCD display accurate UPS working environment through the LCD display panel can be set output voltage and frequency, can be set ECO mode, convenient for user to operate the UPS. Power factor: 0.8/0.9 HP9115C UPS Ordinary UPS Intelligent battery management: With its advanced intelligent charge control mode, UPS Intelligent Power monitoring and Management Sof tware W inpower 2003 : Support Microsoft Windows95/Me/NT/2000/XP/Unux operating system. Suit for TCP/IP local area network; Support TCP/IP network monitoring ; Provide a hierarchical directory structure management network; Unusual event can be notified to user through broadcast, e-mail, messengercall or mobil messager; Automatically detective the UPS model and the communication port; Provide password protection; Support timing boot up / shut off UPS function; Support timing UPS self-test function; Support graphically displayed UPS status function in real time; Support network to deactivate the function of multiple servers and workstations; LCD panel instruction Accept the abnormal power; Support to shut off most of the applications and the preservation of related document; Support the online help function; with data records(including mains,ups,load,battery),and event function,to convenient the system administrator for the routine maintenance. www.soropower.com 26
Back Panel Description: J HP9115C 1KVA HP9115C 2KVA HP9115C 3KVA Communication Port External Battery Intelligent Slot/USB Port(Optional) Communication Network Surge Protection Output Output Terminal Cover Input Power Cord Overcurrent Protection Device Output Terminal Row J EPO + USB Port(Optional) HP9115C 6KVA HP9115C 10KVA HP9115C 15-20KVA Communication Port Intelligent Slot Parallel Port Cooling Fan Input Breaker Maintenance Bypass Switch (Optional) Terminal Blocks Cover EPO + USB Port Available sockets Italian CEE Universal NEMA British Australia 27 www.soropower.com
UPS Power Solutions Expert HP9115C Series Technical Specifications Model Capacity Nominal Voltage Nominal Frequency Input Voltage Range Frequency Range Output Voltage Precision Frequency Precision Harmonic Distortion Overload Capacity Current Crest Ratio Transfer time Battery DC Voltage Recharge Time Recharge Current Panel Display LCD Communication Communication port Working Environment Temperature Relative Humidity Storage Temperature Elevation Physics Characteristic 0 ~40 0~95%(Non-condensing) -25 ~55 1500 m HP9115C 1-10KVA Noise Level <45dB <50dB <50dB Weight (Kg) 1KT 1KT-XL 2 KT 2KT-XL 3 KT 3KT-XL 6 KT 6KT-XL 10 KT 10KT- XL 1KVA/800W 2KVA/1600W 3KVA/2400W 6KVA/4800W 10KVA/8000W 208/220/230/240VAC Single phase 2 wire+g 50/60HZ 115~300VAC 50HZ: (46~54HZ); 60HZ:(56HZ~64HZ) > 0.98 0.99 208/220/230/240X( 1±2%)VAC 50/60Hz± 0.05Hz 120~275VAC 0.8 0.8/0.9(Optional) Linear load<3% Non-linear<6% load > 110% for 47s; 105% < load 125 % for 60s; load > 150% for 25s; 125% < load 150% for 30s; load > 200% for 300ms; load >150% for 0.5s. 3:1 0 ms(ac mode DC mode);(ac mode Bypass<4ms) 36VDC 72VDC 96VDC 192 or 240VDC(Optional) 5 hours to 90%(it means standard model which battery inside UPS) 1A 7A 1A 8A 1A 8A 2A 4A 2A UPS status, input/output voltage and frequency, battery voltage, capacity, load temperature, history records, adjust voltage, ECO mode RS232, SNMP Card(Optional),USB port(optional) N.W 12 6.5 23 10.5 31.5 14 57 18 67.5 20 G.W 14 8 25.5 13 33.5 16.5 59 24 70 24 Dimension :( Wx D x H ) 145X355X220 190X383X318 190X433X318 248X500X616 248X500X460 248X500X616 248X500X460 4A STANDARD: Conform to GB/IEC regulation : EMC: GB7260.2/IEC62040-2 GB/17626.2~5/IEC61000-4-2~5 SAFETY:GB4943 Note: Product specifications are subject to change without further notice. www.soropower.com 28
UPS Power Solutions Expert HP9315C Series Technical Specifications Model Capacity Nominal Voltage Nominal Frequency Input Voltage Range Frequency Range Output Voltage Precision Frequency Precision Harmonic Distortion Overload Capacity Current Crest Ratio Transfer time Battery DC Voltage Charging current Panel Display LCD Communication Communication port Working Environment Temperature Relative Humidity Storage Temperature Elevation Noise Level Physics Characteristic Weight (Kg) Dimension :( Wx D x H ) 208/220/230/240X( 1±2%)VAC 50/60Hz± 0.05Hz 0.8/0.9(Optional) Linear load<3% Non-linear<6% 2A 0 ~40 0~95%(Non-condensing) -25 ~55 1500 m <55dB HP9315C 10-20KVA 105% < load 125% for 60s;125% < load 150% for 30s;load >150% for 0.5s. 3:1 192VDC or 240VDC(Optional) UPS status, input/output voltage and frequency, battery voltage, capacity, load temperature, history records, adjust voltage, ECO mode Rs232, SNMP Card(Optional),USB port(optional),as400(optional) N.W 20 35 35 G.W 24 39 39 248X500X672 10KT 10KT-XL 15KT-XL 20KT-XL 10KVA/8000W 15KVA/12000W 20KVA/160000W 380/400/415VAC 3phase 4wire+G 50/60HZ 208~476VAC 50HZ: (46~54HZ); 60HZ:(56HZ~64HZ) > 0.98 0.99 0 ms(ac mode DC mode);(ac mode Bypass<4ms) 4A 248X500X616 STANDARD: Conform to GB/IEC regulation : EMC: GB7260.2/IEC62040-2 GB/17626.2~5/IEC61000-4-2~5 SAFETY:GB4943 Note: Product specifications are subject to change without further notice. 29 www.soropower.com