COMPACT FLEXIBLE ALL IN ONE INDUSTRIAL PUMP CONTROL ELECTRONIC MONITORING SYSTEM CONTROLLER

Similar documents
EMS467 Monitoring System. Installation and Operations Manual Section 40

WARNING. EMS547 Engine Monitoring System. Installation and Operation Instructions Generic for All Versions. Sensor Inputs (See page 2 for details)

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).

PowerCore Model TEC-10 Installation Manual

PHASED OUT PRODUCT DC2. Microcontroller DESCRIPTION FEATURES ORDERING INFORMATION. BLN Issued: June 1995

PowerView Model PV350 and PV380. Installation Manual Section 78

IEM-2020 INDUSTRIAL ENGINE MODULE

InteliLite MRS17 Click Here to Learn More

Comprehensive Modular Genset Controller

PowerView Model PV750. Installation and Operations Manual Section 78

3-Axis Stepper Drive Datasheet MX3660

INSTALLATION INSTRUCTIONS

SS2200 Remote Controller

GCU401. Technical specification

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

01C06/05. Programmable Controller. TomaHawk 8635A. Key benefits. Typical applications for system control

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

Cabinet Interface Device

Click! 301. Serial to Ethernet Converter

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PowerView Model PV450. Installation and Operation Manual Section 78

310SV SINGLE VALVE GOVERNOR

QTERM -G55. Ethernet-Enabled Graphic Terminal with Object-Based Programming. Rev. 3.4

Product Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx

MC300. BLN Issued: April 2003

SNTL-PCSUITE interface suite

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

2301E ST Steam Turbine Control for Small Generator Applications

7511 / / / 711 / / 731 / Preset 27

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

Installation, Operation and Maintenance Instructions

Easy To Use OEMS Take Note

APP 700 Technical Specification

FX Input/Output (I/O) Modules XM07 and XM14

PowerFlex 400 AC Drive Guide Specification

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation

SDM / 4 Phase Stepper Drive Module. Compact Size & High Power Density, 20-60VDC, 6A Peak. Version 1.0

Applications: Power generator sets and control systems for industrial engine applications.

HelmView Model HV750. Installation Manual Section 78

IRM-5000P. insulation resistance meter. Vanguard Instruments Company, Inc.

PowerView TM Model PV350 and PV380. Operations Manual Section 78

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

100mm Process Indicator Recorder

3000 Series Instructions Read Instructions Carefully!

CHAPTER 1. Introduction Introduction 3

Click Desktop Kit. Click Desktop Kit

SM100. On-Line Switchgear Condition Monitoring

MW/MVAR Transducer Specifications

PGC 4000v2 POWER GENERATION CONTROLLER

Genset Controller Unit Model EMS - GC10. Installation Manual Section

THERMOSTATS & CONTROLLERS

FX06 Field Controller

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

LAUREL ELECTRONICS, INC.

ABB Instrumentation. Specification DataFile. COMMANDER 1900 a rugged, reliable recorder with the full capability to meet your application needs

C1300 Advanced Circular Chart Recorder. C1300 dependable recording in a rugged, functional instrument

iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission

SMART PROGRAMMABLE RELAYS

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

MAJOR VA Power Inverter

PowerView. Model PV-101-C User s Guide Version Catalog Section 78

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

TALON Network Manager- 2 & 6 Express

P/N: AX Distribute your control functions directly onto the valve.

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

MLC 380 R2. For Mechanical Engines. Installation Manual

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Wall-/Pipe Mounted Universal Process Indicator

C1300 Advanced Circular Chart Recorder. C1300 dependable recording in a rugged, functional instrument

PowerView Model PV450. Installation and Operation Manual Section 78

High Voltage DC Meter

TECHNICAL DATASHEET #TDAX050000K CAN

ADJUSTABLE SPEED DRIVES. QX7 Series. HVAC 18-Pulse. Phone: Fax: Web:

Introducing KILOVAC CAP202 Contactors 12 to 900Vdc, 350 amp DC Power

MODCELL 2050R Single Loop Controllers

505 Enhanced Digital Control for Steam Turbines (with Redundancy)

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

Comprehensive Modular Genset Controller

JT400 Multivariable Transmitter

Introduction Circuit Protection

DGC-2000 DIGITAL GENSET CONTROLLER

iologik E1200H Series

NI 6521 Specifications

The CAL range of temperature controllers

SCADAPack 50. Wireless Remote Data Logger

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

PLCADD1616 User Guide 3/29/10. Overview

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

PowerView Model PV485. Installation Manual Section 78

Level-Lance Model 5400A

Neon pr. ph/ ORP measurement. Applications. Description

West Instruments. The MLC compact multi-loop controller... MLC ends the control or integration compromise

SFP450-12BG AC-DC Front-End Data Sheet 12V Output, 450 Watts

Diagnostics (Physical)

SP SP-T-9

PC-200-LLC-GM INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 10/2009 II_PC-XXX-LLC-GM_A1

Transcription:

COMPACT FLEXIBLE ALL IN ONE INDUSTRIAL PUMP CONTROL ELECTRONIC MONITORING SYSTEM CONTROLLER

ONE EASY-TO-USE CONTROL. MANY APPLICATIONS. The EMS PRO is a rugged, all-in-one industrial controller designed for use across multiple engine lines. Driven by customer demand, the EMS PRO is flexible enough to meet the needs of engine-driven pumping equipment applications. A dedicated, micro-processor-based single-engine controller, the EMS PRO offers field-adjustable operating parameters that can be changed without the need for a laptop computer. Able to support both mechanical and J1939 electronic engines, the EMS PRO is ideal for use with a remote modem or in a SCADA system offering Modbus RTU protocol on either the RS232 or RS485 port. Selectable auto start/stop, many auto throttling options and manual operation all at the touch of a button are among the many performance-enhancing features of the EMS PRO via a back-lit operator interface, readable day or night. EASY TO INSTALL. EASY TO LEARN. EASY TO USE.

FEATURES Designed for Interim Tier 4 Engines NEMA 4 Enclosure Backlit Graphical Display Alarm & Shutdown LEDs (Amber/Red) IP66 Rated Sealing Language Choice (English/Spanish) Easy-set, Real-time Clock in 24-hour Format Eight Touch Buttons, Key Selector Switch Compact Size Battery-Saving Sleep-Mode Timer

HARDENED FOR USE IN THE REAL WORLD. Able to withstand a wide ambient temperature range, the EMS PRO comes standard in a NEMA 4 rated enclosure secured by four rubber shock mounts. Inside is a backlit graphical display visible in all types of conditions. Easily accessible touch buttons and a large, clear cover round out the compact, fully functional control unit. Operators can choose from many start/stop and throttling options, as well as manual starts and throttling with very basic training on both mechanical- and electronic-control engines. Auto-start and time-stamping are quickly accomplished through the easy clock set-up. Other built-in functions include auto-start, engine running with no operator present, engine throttling to demand (pressure or level), service reminders and TSC1 speed control messages. For quick and accurate troubleshooting, the EMS PRO can display vital engine and equipment information including diagnostic codes, first-out shutdowns and/or alarms. The unit stores the last 10 engine shutdowns with a date-and-time stamp, and records engine and system information at the time of shutdown.

TECHNICAL SPECS Operating Voltage: Engineered for 12 and 24 VDC systems (8 VDC Minimum, 32 VDC Maximum) Operating Temperature: - 40 to 80 (- 40 to 176 F) Storage Temperature: - 40 to 80 (- 40 to 176 F) Environmental Sealing: IP66 Sweep Sine Vibration Test: X, Y, Z axis, frequency sweep from 10 to 2000Hz, 10G peak Random Vibration Test: X, Y, Z axis, frequency range 5 to 2000Hz, 7.68Grms Operating Shock Test: X, Y, Z axis, 50G shock, 11ms pulse Relative Humidity: 95% RH @ 60 C Standby Current: @ 12 VDC, 220 ma; @ 24 VDC, 244 ma LEDs: Alarm (Amber); Shutdown (Red) CAN Bus: SAE J1939 Compliant Enclosure: Polycarbonate NEMA 4X (UL Certified) Analog Inputs: 12 designated via program; sender/ground digital, 4-20 ma, 0-5 VDC Digital Inputs: 8 high/low Frequency: 1 optically isolated input for speed reference, magnetic pick-up Fuel Sender Input: 33 Ohm full, 240 Ohm empty Analog Output: 1 optional; 4-20mA or.4 to 4.6 VDC. Output pin assignment changes between two selections. Digital Outputs: 3 FET B+ (rated at 1A) tied to relay outputs.) Relays: 1 SPDT and 8 SPST 5 Amp pilot relays User Interface: 8 button membrane switch Connectors: 21 pin and 31 pin Deutsch HDP20 Series Mounting: 4 isolated.75 inch rubber shock mounts Shipping Weight: 11 Lb. (5 kg.) Shipping Dimensions: All Models 15 x 15 x 11 in. (381 x 381 x 279.4 mm)

D I M E N S I O N S 11.30 in. (287 mm) 7.70 in. (196 mm) Front Side 9.41 in. (239 mm)

ELECTRONIC MONITORING SYSTEM CONTROLLER FW Murphy 5311 South 122nd East Avenue Tulsa, Oklahoma 74146 USA Phone: +1 918.317.4100 Fax: +1 918.317.4266 E-mail: sales@fwmurphy.com Web site: www.fwmurphy.com Frank W. Murphy, LTD. Church Rd. Laverstock, Salisbury SP1 1QZ U.K. Phone: +44.1722.410055 Fax: +44.1722.410088 E-mail: sales@fwmurphy.co.uk Web site: www.fwmurphy.co.uk FW Murphy Instruments (Hangzhou) Co. LTD. 77 23rd Street Hangzhou Economic & Technological Development Area Hangzhou, Zhejiang, 310018, China Phone: +86.571.8788.6060 Fax: +86.571.8684.8878 E-mail: apsales@fwmurphy.com 1010643 11-10