MIMA V 1.0. MS IMS Mapper. Peak Identification in Ion mobility Spectrometry

Similar documents
Fatty Acid Methyl Ester (FAME) RTL Databases for GC and GC/MS

Agilent MassHunter Qualitative Data Analysis

How to Run the CASPiE GCMS

Building Agilent GC/MSD Deconvolution Reporting Libraries for Any Application Technical Overview

Chromeleon software orientation

Agilent RapidFire 300 High-throughput Mass Spectrometry System

Retention Time Locking with the MSD Productivity ChemStation. Technical Overview. Introduction. When Should I Lock My Methods?

UPDATING PESTICIDE RETENTION TIME LIBRARIES FOR THE AGILENT INTUVO 9000 GC

Thermo Xcalibur Getting Started (Quantitative Analysis)

Agilent G2727AA LC/MS Data Browser Quick Start

MassHunter File Reader

Automated Submission for Analysis Processing (ASAP) Operator s Guide Dionex Corporation

This manual describes step-by-step instructions to perform basic operations for data analysis.

Agilent GC/MSD Instructions

Agilent MassHunter Workstation Software 7200 Accurate-Mass Quadrupole Time of Flight GC/MS

OpenLynx User's Guide

Agilent 5977 Series MSD System

Agilent MassHunter Drug Analysis Mode Using Quantitative Analysis Workflow Guide

ChromQuest 5.0 Quick Reference Guide

Skyline High Resolution Metabolomics (Draft)

REVIEW. MassFinder 3. Navigation of the Chromatogram

Agilent MassHunter Metabolite ID Software. Installation and Getting Started Guide

Getting Started. Environmental Analysis Software

Retention Time Locking Operation

Xcalibur. QuickQuan. User Guide. XCALI Revision C July For Research Use Only Not for use in Diagnostic Procedures

Protein Deconvolution Quick Start Guide

MRMPROBS tutorial. Hiroshi Tsugawa RIKEN Center for Sustainable Resource Science MRMPROBS screenshot

Workflow Optimization with EZ Access and ChemStation Browser. Tony Brand, Ph.D., Agilent Technologies, Inc., North Carolina, USA

Use of NIST Library with Finnigan Xcalibur Software

Chromatography Software Training Materials. Contents

SIMAT: GC-SIM-MS Analayis Tool

Procedures for Group Quantitation

TM1 Technical Bulletin

Agilent G6854 MassHunter Personal Pesticide Database

Network Analy Network Anal sis with sis with Cy C toscape

Chromeleon / MSQ Plus Operator s Guide Document No Revision 03 October 2009

MRMPROBS tutorial. Hiroshi Tsugawa RIKEN Center for Sustainable Resource Science

182 Introduction to Microsoft Visual InterDev 6 Chapter 7

MassHunter Personal Compound Database and Library Manager for Forensic Toxicology

Quick Start Guide. Introduction. Importing Raw Data. Method 1: Use Open Data Panel

Xcalibur Library Browser

Chromatography Systems News Flash

TraceFinder Analysis Quick Reference Guide

Introduction to Time-of-Flight Mass

Package CorrectOverloadedPeaks

Agilent 6400 Series Triple Quadrupole LC/MS System

CALIBRATION of a STREAM

CLARITY DEMO. Clarity Demo Software. Code/Rev.: M003/70E Date:

Getting low-resolution GC-MS data on the JEOL GCMate Introduction

Lionbridge Connector for Drupal 8 TMGMT. Setup and User Guide

BizViz How-to-Guide. Business Story. Copyright All rights reserved. No part of this publication may be. Release : 2.0. Date : Feb.

DESCRIPTION. DataApex Clarity 32bit multi instrument chromatography station for Windows

StarFinder. Operation Manual. Star Chromatography Workstation Version 6

Agilent 5977 MSD Overview

SequencePro Data Analysis Application. User Guide

Data Handling and Reports

How to design and print cards using a database connection with. emedia CS Software

Annotation of LC-MS metabolomics datasets by the metams package

Q Exactive HF-X Software Manual

SAS Model Manager 2.3

How to Guide. Create a Data Set. Version: Release 3.0

Empower Data Exporter. The Empower Data Exporter is for use with Empower 2154 and requires the Microsoft.NET Framework version 2.0.

GPS Explorer Software For Protein Identification Using the Applied Biosystems 4700 Proteomics Analyzer

Agilent MassHunter LC/SQ ChemStation Integration Software

Import and preprocessing of raw spectrum data

Package Metab. September 18, 2018

Tutorials. Saturn GC/MS Workstation Version 5.4. Varian Analytical Instruments 2700 Mitchell Drive Walnut Creek, CA /usa

Automation Engine. Working with Shuttle

Agilent OpenLAB CDS. Version 2.2. Release Notes. OpenLAB CDS Release Notes 1

New Features of Deconvolution Reporting Software Revision A.02 Technical Note

Agilent ChemStation Plus

Rapidflows Integration with External Systems Whitepaper (English) Version 2.02/18/Feb

GC-MS ChemStation Reference Guide. Last Updated July 2014

Agilent G6854AA MassHunter Personal Compound Database

JobRouter Product description Version 3.0

Attaching Codesoft 6 to an ODBC Database

MassLynx 4.1 SCN 804. Release Notes. SQ Detector 2

HT Remote Management System User Manual

Agilent 7890 Series Gas Chromatograph

Standard Operating Procedure for the HPLC-ICP-MS System By Celina Dozier Fall 2017

Watson TSQ Module Version 1.1

PANalytical Epsilon 5 XRF spectral acquisition, processing and reporting

What s New in Empower 3

BTA Billing Online Support Statement File Reference Guide

Using OPUS to Process Evolved Gas Data (8/12/15 edits highlighted)

firefly is a web-based text-to-speech reading tool that allows students to access documents in HOW TO USE firefly Firefly Basics-Web Version

Xcalibur. Getting Productive: Quantitative Analysis. XCALI Revision C June For Research Use Only Not for use in Diagnostic Procedures

Sitecore InCopy Connector 1.0

DOCUMENTUM D2. User Guide

Clarity. Clarity Demo. Code/Rev.: M003/60A Date: Fax: Petrzilkova 2583/ Prague 5

DDFile Catcher

The Agilent 5975 inert MSD: New Tools for the Forensic Analyst

Agilent G6825AA METLIN Personal Metabolite Database for MassHunter Workstation

User Guide. Data Preparation R-1.0

LC-MS Data Pre-Processing. Xiuxia Du, Ph.D. Department of Bioinformatics and Genomics University of North Carolina at Charlotte

Gas chromatograph Agilent 7890A and UniChrom

Pathway Analysis of Untargeted Metabolomics Data using the MS Peaks to Pathways Module

Quick Guide to the Star Bar

Analysis of Networks with Interactive MOdelling. User s Manual

Invoice Approval Guide

Transcription:

MIMA V 1.0 MS IMS Mapper Peak Identification in Ion mobility Spectrometry

I. What is MIMA? MIMA is a software package for mapping mass-spectrometric (MS) data to corresponding ion-mobility spectrometer (IMS) derived chromatograms. Its focus is the automation of the MS to IMS and IMS to IMS peak assignment. II. Method summary Ion-mobility spectrometry is an analytical detection method for volatile substances and is often coupled with mass spectrometry. Peak assignment of MS and IMS data is a frequent operation for identification of indistinct peaks in complex IMS samples. A drawback of a manual comparison of MS and IMS measurements is the high expenditure of time and the requirement of at least two parallel running software tools to compare both chromatograms. MIMA automates this process by generating an IMS Layer using both the corresponding OpenChrom - preprocessed MS data and an IMS database. The layer contains the analytes from the MS measurement and the corresponding coordinates within the IMS-chromatogram. It can be automatically superposed on IMS chromatograms using the IMS analysis software VisualNow. III. Where is MIMA developed? MIMA was developed at Max Planck Institute Informatik, in cooperation with the KIST Europe, Saarbrücken. IV. MIMA input formats First, for the generation of an analyte list using OpenChrom, a MS data file corresponding to the IMS file is needed Second, for the generation of an IMS Layer an IMS Database is necessary V. MIMA output formats The MIMA software package creates an analyte list as well as an IMS Layer in Microsoft Excel format (*.xls). VI. Languages The MIMA software supports three languages: English, German and French.

VII. Workflow MS - IMS: Assuming we would be interested in identifying the peak, highlighted by an arrow (see Fig. 1), in the IMS chromatogram by crosschecking a corresponding gas chromatograph-mass selective detector (GC-MSD) measurement we would perform the following steps: Fig. 1 Peak of interest. Configuration of Open Chrom: 1. Install OpenChrom according to the instructions given on the website (tested for version 0.8.0). 2. Install the following plugins via Plug-Ins -> OpenChrom Marketplace: -Agilent MSD Import Converter -NIST-DB Connector 3. Use the OpenChrom preferences dialogue to set the correct NIST database (nistms$.exe) via Window-> Preferences->Identifier-> Nist Identifier (Set NIST path/ Set number of Targets =10) and run the OpenChrom Demo. 4. Before you can use the batch functionality of the OpenChrom open source software to generate a report file (*.txt) from a *.MS file (example) the following two steps have to be performed:

First set a new OpenChrom project in the Project explorer (window->select view- >project explorer) by right-clicking in the explorer window and choose New -> Project -> MS Projects-> Analysis Project and name it (Fig.2) Fig. 2 Start a new analysis project and name it Second, open a new batch process job in by right-click in the Project explorer window and choose New -> Other -> MS Projects-> Analysis Project and save it in your new generated analysis project folder (Fig.3). Fig. 3 Start a new batch process job and select your new analysis project as saving folder. 5. Then edit the batch process in the following way (Fig. 4): Select the input file type *.MS with Input files-> Add *. Add the Process Entries categories Peak Detector, Peak Integrator and Peak identifier with the corresponding plugins Peak Detector #1, Peak Integrator #1 and NIST Peak Identifier to the process entries list.

Select in the report supplier OpenChrom.txt as file format and define an output folder. Fig. 4 Edit the batch process. 6. Run the batch process in Batch Process Job Editor- > Run the batch process to create a report file from your MS data file (Fig.5). Fig. 5 Run the batch process.

Configuration of MIMA: 1. Start MIMA by double clicking. Generate a new project in File -> Create Process-> MS- IMS Mapping and enter a process name (Fig.6). Fig. 6 MIMA user interface 2. Drag and drop the OpenChrom created report file *.txt to the field A (Fig.6). A B D C Fig. 7 Process Setup 3. Select the directory of the IMS reference database file using the Open button in B (Fig.7). 4. Select the result folder using the Open button in C (Fig.7). 5. Select one of the following processing options in D (Fig.7): All Analytes: Consider all Analyt-Proposals for a GCMS-Peak in the IMS DB

Best Matching Analyte: Select the first Analyte that occurs in the IMS DB Best Analyte: Only search for the best Analyte candidate for each GCMS peak in the IMS DB 6. Start the calculation by pressing the Start Processing button in D. 7. Load your chromatogram, which you want to analyze in the IMS software VisualNow. Build an IMS-Set. Load the MIMA created layer file (Fig. 8). Fig. 8 Peak of interest annotated with layer.

VIII. Workflow IMS IMS Layer Annotation 1) Open Program: Double click on MIMA-1.0.jar And Create a Layer Annotation process. Fig. 9 MIMA user interface 2) Fill the required information: B A D C E Fig. 10 Process Setup. A. Select the IMS DB file using the OpenButten. B. Select the Layer files in your file-browser and drag them into the corresponding field. C. Select the result folder using the Open button. D. Select a Processing Option:

i. Euclidean Distance : Select the analyte of minimal Euclidean distance to the target peak. ii. Solely Overlapping: Select the analyte of maximal overlap to the target peak. iii. Overlap->Eucl. Diststance: Apply as ii, for those target peaks without overlapping peaks or no decision is possible, the Euclidean distance is applied. iv. Eucl. Distance -> Overlap: Apply as i, for those target peaks without single closest peak, the overlap is applied. 3) Start the calculation by Pressing the Process button E