Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A

Similar documents
Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

PS8 - II. Professional Power Sequencer. User s Manual

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

Installation and Operation

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

EATON 5S 850/1200/1600

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

IS Series Manual. 19 Pro Series Rack Mount (RK) Faceplate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) colours

Operating Instructions

Powerware 3105 UPS User s manual

Disclaimer. Note that the Midspan is designed for indoor use only.

Zonit μats TM Users Guide μats1-lv Version 1.2

Operating Instructions

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

High Power over Ethernet Midspans PD Port Model PD Port Model

Back-UPS RS 550 Installation & Operation

Installation and Operation Back-UPS Pro 900

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

MODEL 805 USER MANUAL

Powerware 3105 UPS User s manual

User Guide. Control Box. RoscoLED TM.

User Guide Automatic Transfer Switch (ATS)

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

* * Agilent Power Distribution Unit (PDU) Installation Guide

Installation Manual for D1800 Series High Power PoE Midspan Power Supply

Back-UPS RS APC Back-UPS RS 800VA 120V Black

PD-6506, PD & PD-6524

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

Broadband Automatic Disconnect Switch. User Manual

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Liebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL 1.1 SUMMARY

Installation and Operation Back-UPS Pro 900

Innovative Circuit Technology Ltd.

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Product Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23

MAINS DISTRIBUTION UNIT MDU14-CO

TOT AVR Series Manual

XPD-28 2:8 DMX & RDM Splitter User Manual

CMSA-100 Manual. Cinema Media Server Automation

Model HM-535 Power Supply Installation and Service Instructions

PAT-Cal 2 TECHNICAL MANUAL

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

Installation and Operation Back-UPS Pro BR700G-TW

Weathersafe Vision. Installation & Operating Instructions

S82S (3/7.5-W Models)

Basic PDU Modules SW Meter PDU SW Meter Switch PDU SW Three Phase PDU. How to install 11-12

REDUNDANT POWER SUPPLY SYSTEM FOR NETGEAR RPS CAPABLE ETHERNET SWITCHES

ARTiPRO. User Manual. (Model 910 & 920)

VBT-75 S2 VACUUM BOTTLE TESTER

THIS PAGE LEFT BLANK

The Martin Experience. Martin Audio CMX1A Cinema Controller MARTIN AUDIO. All material Martin Audio Ltd. Subject to change without notice.

MFJ ENTERPRISES, INC.

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

iconverter 2-Module Power Chassis

Premium Online Series

S66 Series Electronic Fan Speed Control

Line Impedance Stabilization Network (LISN)

AVR Series Manual. Isolate. Restore. Inspire! Audio / Video Power Isolation Units with Automatic Voltage Regulation

QSW16M 16 Chn PoE managed switch

Split2.8 RDM. 2 input DMX/RDM Splitter. User guide

Innovative Circuit Technology Ltd.

Installation and Operation Manual Back-UPS BR900G-RS

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

Kramer Electronics, Ltd. USER MANUAL. Model: VM-4HDCP. 1:4 DVI Distributor

MC 11 EB-2 Power supply cabinet with external bus, AC version

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

Click Desktop Kit. Click Desktop Kit

User Guide. JBL Professional UniAmp Power Amplifier Module Model 1214

TL-PA4010 AV600 Powerline Adapter

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

ORYON RING LIGHTS. 14 in. Ring Light and 18 in. Ring Light. Quick Start Guide. What s Included

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

SP-1400P POWERED SPEAKERS OWNERS MANUAL

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

TECHCONNECT TC2-HDMI14 OWNERS MANUAL

TPC25 active crossover. user manual

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

Hoist Controller for Low Voltage Hoist Instruction Manual

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

NanoServ. Setup Guide. Thin System/Ultra-Thin System. 1.0 What s included with the NanoServ. 2.0 Steps for setting up the NanoServ

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

Kramer Electronics, Ltd.

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

PanelView Plus/VersaView CE Terminals and Display Modules

Panduit Basic Rack PDU with Local Meter

User Manual Back-UPS BE650MC

Operating Instructions

Rack Mount Power Supplies

MFP5G, MFP8G, & MFP12G D-M-E Smart Series Mainframes

Hoist Controller for Direct Voltage Hoist Instruction Manual

SOLARIMMERSION IV Advanced Installation Manual v1.9

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

Network Camera. Quick Guide DC-B1203X. Powered by

Transcription:

PDU16-AV 20A AC PDU WITH POWER MONITOR 2U Rack Mount PDU with Overload Protection & Power Monitoring 2U high Horizontal Mounting unit designed to provide versatile hook-up for the distribution of AC power within Audio Visual & Multimedia applications. Main Input Protection Output Output Protection Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A Illuminated Circuit Breaker 10A overload protection 4 Way IEC C13 Outlet Strip with max combined load of 10A 2 Dual USB 5V 1.8A charger modules Circuit B 5 Universal sockets useable with plugs from the UK, US, Europe and Australia, with a Maximum Combined Load 10A. (Schuko type plugs have a 2 pin connection only) For full universal plug application guide see appendix A Illuminated Circuit Breaker 10A overload protection LCD Monitor LCD Power Monitor giving Voltage, Current, Power & Energy Levels. Earth Link M4 Screw Terminal for Rack Grounding Usage Nominal Voltage: Usable Voltages Frequency: Max. A/C Output: Case Size: Weight: 230V 240V full range 50/60HZ full range Current 20A 87 x 98 x 430mm (O.A.483mm) 2.5Kg (5.5Lbs) Compliance All components used in this conform to current RoHS, CE & UL certification - E&OE (EMI:EN55022 (CISPR22) Class B; EN61000-3-2,3 EMS:EN61000-4-2,3,4,5,6,8,11; Light industry level, criteria A)

Power Monitoring Features 1. Voltage, Current, Active Power & Energy Usage 2. Overload alarm function: over power alarm - backlight and the power figure will flash 3. Setting of power alarm threshold function 4. Power button clear function. 5. Power-down data storage function. The universal output socket has been designed for worldwide applications. It is rated at 16A 250Vac and is compliant with CE and RoHS. For Euro Schuko plug types the ground pin will have no connection. Should this be a requirement then the PDU16-EU is available with Schuko type sockets. Appendix A Designed & Manufactured in the UK by Penn Elcom Ltd 9-10 Parsons Road, Parsons Industrial Estate, Washington Tyne & Wear, NE37 1HB, UK 0191 416 1717 or www.penn-elcom.com

PDU16-AV 20A AC PDU WITH POWER MONITOR USERS GUIDE 10A Trip Switches for Channels A & B In the event of overload these will cut power to the output sockets RED Neon Indicators on the trip switches will show there is AC power in the unit. Should these not be Lit then - 1st check the power is connected & none of the outputs are overloaded Dual USB Charging Outputs 5V at 1.8A Short circuit & overload proof AC~Outputs 5 sockets on Channel B with max combined load of 10A Power Monitor This panel displays Overall Voltage - Current - Power & Energy Level being Used AC~Outputs 4 Way IEC C13 Outlet Strip on Channel A with max combined load of 10A for use with C14 Plugs AC~Output 1 Universal socket on Channel B with max combined load of 10A Earth Strap Point For attachment to the rack unit This Unit Must Be Earthed AC Power Input A Neutrik 20A powercon Connector is supplied for A/C power input. PLEASE NOTE FITTING A 13A PLUG WILL REDUCE THE OVERALL POWER RATING E&OE Dual USB Charging Outputs 5V at 1.8A Short circuit & overload proof

Neutrik 20A powercon Power input Connector NAC3FCA 10A C14 Output Connector Plug UNIVERSAL PLUG GUIDE Channel B on the PDU16-UN model has 8 Universal sockets compatible with plug types shown below: For Euro Schuko plug types the ground pin will have no connection.

POWER MONITOR DISPLAY Functions 1. Electrical parameter measurement function (voltage, current, active power, energy) 2. Overload alarm function (over power alarm threshold, backlight and power flashing to alarm). 3. Power alarm threshold preset function (can set power alarm threshold). 4. The reset function of energy key. 5. Stores data when powered off. 6. Backlight function. User Button Key Functions 1. Backlight Control: just press the button to turn on or off the backlight. The backlight has a memory function and will store its state when powered off. 2. Energy Display Reset A: Hold down the button for 5 seconds until the number in energy display section flashes, then release. B: Push the button again, then once the energy value is cleared it will exit the reset. If you don t want to it to clear, then hold down the button for 5 seconds again until the number stops flashing, this means the energy value has not been cleared and it will reset. 3. Power Alarm Threshold A: Hold down the button key until the LCD screen display shows SET CLr, then release to enter the setting mode B: The Power section will display the current alarm value and the last digit should be flashing, To add plus 1, press down in 3 second intervals - the digital point will shift automatically C: To finish setting, hold down the button for 5 seconds to store the settings and exit, the range of active power threshold is 0.0~22.0kW Designed & Manufactured in the UK by Penn Elcom Ltd 9-10 Parsons Road, Parsons Industrial Estate, Washington Tyne & Wear, NE37 1HB, UK 0191 416 1717 or www.penn-elcom.com

PDU16 series POWER DISTRIBUTION UNIT OPERATION & USER ADVICE PleasereadthefollowinginformationbeforeinstallingorusingyourPowerDistributionUnit Safety and Grounding (earth) This PDU is intended for indoor use only. Do not install this PDU where excessive moisture or heat is present. Never install any wiring, equipment, or PDU's during a lightning storm. Always connect this PDU into a three-wire, grounded power outlet. The power input cable should be connected to appropriate branch circuit/mains protection (fuse or circuit breaker). Connection to any other type of power outlet may result in a shock hazard. Use only the supplied brackets for mounting. Never work alone under hazardous conditions. Check that the power cord, plug, and socket are in good condition. Disconnect the PDU from the power outlet before you install or connect equipment to reduce the risk of electric shock if you cannot verify grounding. Reconnect the PDU to the power outlet only after you have made all connections. Use a protective earth connector with equipment. This type of connector carries the leakage current from the load devices (computer equipment). Do not exceed a total leakage current of 3.5mA or a risk of electrical shock will result. Use the Stud Earth point on the front of the PDU to directly ground to the rack. ALWAYS make sure the equipment that has been connected to the PDU is OFF, before switching on the PDU, as the Inrush Current can blow the power fuse and activate the protection circuit. All equipment plugged into this unit should have the correct fuses fitted for their current draw. Penn Elcom Ltd excepts no responsibility or liability for any equipment connected to this unit E&OE GUARANTEE YOUR EQUIPMENT IS GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF PURCHASE OF THE PRODUCT AGAINST ANY DEFECTS DUE TO FAULTY MATERIALS OR FAULTY MANUFACTURING. DURING THIS PERIOD, REPLACEMENT OR REPAIR TO THE UNIT WILL BE MADE WITHOUT CHARGE BY ANY AUTHORISED DEALER OR THE FACTORY SUBJECT TO THE FOLLOWING CONDITIONS. The fault must be entirely due to faulty materials or faulty manufacture. The defect must NOT have been caused by poor installation, accidental damage, misuse or failure to comply with the instructions given in the users guide. If at any time during the guarantee period a part or parts of the equipment are repaired with a part or parts not supplied or approved by us; or if the equipment has been dismantled or repaired by any person not authorised by the us, then the guarantee shall immediately cease and become void. Evidence of the date of purchase must be produced at the service point to obtain the benefit of this guarantee. Any carriage charges relating to the guarantee will be the responsibility of the purchaser. This guarantee applies to the original purchaser only and the equipment must have been purchased or financed from new, this guarantee cannot be assigned or transferred. The company reserves the right to replace the equipment or repair it at their discretion, any defective part shall become the property of the company. This guarantee applies to equipment purchased and used within the E.E.C. The importers of equipment in non E.E.C. countries are responsible for the guarantee of this unit. Parts required under guarantee are free. Shipping charges for components will be charged at cost. The guarantee shall become void if the equipment is at anytime used on any supply circuit or voltage range other than that specified on the equipment. 12. THIS GUARANTEE DOES NOT IN ANY WAY AFFECT YOUR STATUTORY RIGHTS AS A CONSUMER.