CHENBRO. 80H A0 Rev A0 User s Manual 01 / 03 / 2011

Similar documents
CHENBRO. Storage Chassis 4-Port Mini-SAS Backplane 80H C0. User s Manual. September / 10 / 2009

CHENBRO. Storage Chassis 4-Port Mini-SAS Backplane 80H User s Manual. Version A0. July / 28 / 2008

CHENBRO. 4-Port SAS / SATA-II Backplane 80H User s Manual. Version 1.1~1.3. July / 18 / 2008

CHENBRO. 8-Port 6Gb/s SATA Backplane 80H A0. User s Manual. September / 2010

CHENBRO. SR30169 Server Chassis 4-Port 6Gb/s SAS/SATA Backplane. User s Manual 80H A0. Revision: 1.1. Dec / 3 / 2013

CHENBRO. 6-Port 3Gb/s Mini-SAS Backplane 80H A0. User s Manual. August / 2010

CHENBRO. User s Manual SK to-1 SATA / SAS HDD Storage Kit. Version A2~A4. May / 26 / 2008

80H A0 80H A0 80H A0

CHENBRO. User s Manual port 6Gb/s SAS Expander Backplane 80H A0. Version A0

CHENBRO CK port SAS Expander Card User s Manual. Version B0. September / 01 / 2009

SAS Expander Card User s Manual CHENBRO. SAS Expander Card User s Manual. April / 01 /

CHENBRO. 24-Port 3.5 mini-sas Backplane with Expander 80H A0. User s Manual. December 2012

In Win. Storage Chassis 10-Port 6Gb/s 2.5 Mini-SAS+SATA Backplane. User s Manual 2014/8/10

In Win. Storage Chassis 4-Port 6Gb/s SAS/SATA Backplane 3RAMPD User s Manual 10/02/2012

In Win. Storage Chassis 4-Port 6Gb/s SAS/SATA Backplane. User s Manual 2015/08/06

Chenbro. ES34169 Chassis User s Manual. April / 2 /

CHENBRO CK port 6Gbit SAS Expander Card User s Manual. Version A0. September / 01 / 2010

SIDEBAND#2 3 JP43 JP37 JP45 JP38 JP41 J10 I C#2 JP36 JP50:I2CRST#1 JP38:I2CRST#2 OFF:SGPIO ON:I2C JP50 JP29 2 I C#1 JP40 JP44 JP51 JP29:9072 RESET

BPN-NVMe3-116UN Backplane USER'S GUIDE

CSE-M14T Mobile Rack USER'S GUIDE

03-240r2 SAS-1.1 Internal wide connector and cable 28 April 2004

05-023r0 SAS-1.1 Connector figures 23 December 2004

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems.

3U 16-bay PCI-Express Rackmount JBOD Chassis. Installation Guide

03-240r5 SAS-1.1 Internal wide connector and cable 11 September 2004

SAS-933E The SAS-933E2/E1 Storage Backplane USER'S GUIDE

Storage Backplane Specifications

BPN-SAS-825MTQ Backplane

SASTracer Protocol Analyzer Configurations:

SAS-833TQ BACKPLANE USER'S GUIDE

RM414 User s Manual. Preliminary Release

RM238 Series. Rackmount Chassis User Manual. January 2019 Version 1.0

MegaRAID SAS e RAID Controller

A33606-PCI-01 SAS-2 Expander User Manual. Version: Document Number:

SAS-113TQ BACKPLANE USER'S GUIDE

BPN-SAS3-825TQ BAckPlANe USeR'S GUIDe 1.0a

Enclosure Cabling Guide for Intel C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures

SAS/SATA II Multi-lane. lane Connector/cabling

HighPoint NA381TB3. 4U 24 bay ( 3.5" / 2.5" ) Thunderbolt 3 Storage and PCIe Expansion. User Manual

Download the appropriate 3ware ECPT Code from or contact CI Design

NA381TB3. 4U 24 bay ( 3.5" / 2.5" ) Thunderbolt 3 Storage and PCIe Expansion. User Manual

BPN-SAS-F424-A6 Backplane USER'S GUIDE

Intel 4-Processor Server System S7000FC4UR Configuration Guide Intel Value and Enterprise Servers

Turbo PCI Express. PCI Express adapter for desktop PC. PCIe 4 to PCIe 4 data cable, 1.5 meter. Turbo ExpressCard. ExpressCard 34 adapter for laptop

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

BPN-SAS3-743A Backplane USER'S GUIDE

SAS-809T/TQ BACKPLANE

NA380A-G3. 4U 24-Bay External PCIe 8 JBOD Storage with PCIe Slot Expansion. User Manual

MegaRAID SAS 9285CV-8e RAID Controller. Quick Installation Guide

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

1.0 S UPER SAS815TQ #0 ACT IN REV 1.00 #2 JP29:9071 RST JP18 JP18:BUZZER RESET JP46 JTAG UPGRADE JP29 SIDEBAND +5V +5V +12V +5V +12V JP42 JP33 JP34

Intel Storage Server SSR212MC2

BPN-SAS3-F418-B6N4 Backplane USER'S GUIDE

SAS Standards and Technology Update Harry Mason LSI Corp. Marty Czekalski Seagate

Copyright. Technical Support. Web Support. Support. Phone Support. Copyright 2006 Chenbro Micom Co., Ltd.. All rights reserved.

19 Rackmount Cases A3211. Enrich Your Product Line and Build Your Brand Awareness

SAS JBOD Installation Reference Guide Revision 1.0

USER S GUIDE. 3 Gbit/s Serial Attached SCSI Host Adapters

Proposal for SAS 2.x Specification to Enable Support for Active Cables

Supports up to four 3.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs. A size-converter

Intel /100Mbps Ethernet Controller 32bit PCI Slot x2. ATI Rage XL Video Chip with 4MB Video RAM onboard 64bit PCI Slot x4

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

12G SAS/SATA Drive Modules

SERVER TECHNOLOGY H. Server & Workstation Motherboards Server Barebones & Accessories

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

DNS-2608 Enterprise JBOD Enclosure User Manual

User Manual HPC U Tower/Rackmount Chassis for EATX Serverboard with 8 Hot-swap Hard Drive Cages

Enclosure Management Cabling Guide for Intel C610 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures

RocketRAID 3622/3620. SATA 6Gb/s PCI-Express 2.0 x 8 RAID HBA

Three Hundred. User s Manual Manuel de l utilisateur Anwenderhandbuch Manuale per l operatore Manual del usuario

2 Drive 2.5in Trayless Hot Swap SATA Mobile Rack Backplane

Proposal for SAS 2.1 Specification to Enable Support for Active Cables

Thermal Test Report. Model Name : RM Rev : B

Easy compatibility. Mobile rack backplane for 2.5in SATA/SAS drive. StarTech ID: SATSASBP125

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

Mobile Rack Backplane for 2.5in SATA/SAS Drive

GEN3 PCIe Card and Drive Modules

A33606-AIC-02 User's Guide

Describe the features and performance characteristics of server-class hard disks and solid state drives.

Quanta JB9 (M4600H) JBOD System Overview

Essentials. Expected Discontinuance Q2'15 Limited 3-year Warranty Yes Extended Warranty Available

Proposal for SAS 2.x Specification to Enable Support for Active Cables

Front-loading drive bays 1 12 support 3.5-inch SAS/SATA drives. Optionally, front-loading drive bays 1 and 2 support 3.5-inch NVMe SSDs.

24/12/8 UP Server Nodes in 3U

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

P RO D UC T SEL EC TOR GUID E. Storage Adapters. March 2012

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est

Atlas Quiet Mini Server Case. User s Manual Manuel de l utilisateur Anwenderhandbuch Manuale per l operatore Manual del usuario

RAID Controller Considerations

VP1-250X USER S MANUAL

ThinkStation P500/P510, P700/P710, and P900/P910 How to Create and Configure RAID Arrays. Version 1.1

HP ProLiant DL165 G7 Server

SAS-216EL1/EL2 BACKPLANE USER'S GUIDE

NEC EXPRESS5800/R320a-E4 Configuration Guide

RACK-220 CHASSIS USER S MANUAL

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Chenbro RB14604/08 Spares/Accessories List and Configuration Guide

Setting new Standards. Active Extenders PCIAX CPCI64. Hot Swap PCI Bus Extender Boards PCI. User Manual Revision 5.

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Transcription:

2.5 HDD 8-Port 6Gb/s Backplane 80H10323406A0 CHENBRO Storage Chassis 2.5 HDD 8-Port 6Gb/s Backplane 80H10323406A0 Rev A0 01 / 03 / 2011 1

2.5 HDD 8-Port 6Gb/s Backplane 80H10323406A0 Copyright Copyright 2006 Chenbro Micom Co., Ltd.. All rights reserved. Unless otherwise indicated, all materials in this manual are copyrighted by Chenbro Micom Co., Ltd.. All rights reserved. No part of this manual, either text or image may be used for any purpose other than internal use within purchasing company. Therefore, reproduction, modification in any form or by any means, electronic, mechanical or otherwise, for reasons other than internal use, is strictly prohibited without prior written permission. Chenbro Micom Co., Ltd. reserves the right to make improvement and modification to the products indicated in this manual at any time. Specifications are therefore subject to change without prior notice. Information provided in this manual is intended to be accurate and reliable. However, Chenbro Micom Co., Ltd., assumes no responsibility for its use, nor for any infringements upon the rights of third parties, which may result from its use. Technical Support Chenbro works hard to offer our customers maximum performance from our chassis. But in case you have any problem with our product you can find supports from the following resources. Web Support Detail information of our products is in our website. You can find technical updates, installation guides, FAQs, technical specifications and more. Our web address is:. Email Support You can also fill out the technical support form at our Technical Support page. You technical issue inquiries will be sent directly to our support professionals. Phone Support You can also contact Chenbro HQ or branch office for immediate support; contact Information is as following: Chenbro HQ Chenbro Europe B.V. Chenbro Micom (USA) Inc. Tel: 886-2-8226-5500 Tel: 31-40-295-2045 Tel: 1-909-947-3200 Fax: 886-2-8226-5423 Fax: 31-40-295-2044 Fax : 1-909-947-4300 Chenbro UK LTD Chenbro China Office Tel: 44-(0)161-973-8152 Tel: 86 010-6709-1786 Fax: 44-(0)161-962-8653 Fax: 86 010-6709-1786 2

2.5 HDD 8-Port 6Gb/s Backplane 80H10323406A0 Contents Copyright...2 Technical Support...2 Contents...3 Revision History...4 Backplane Specification...5 Accommodation Chassis...5 Backplane Layout...6 Backplane Connectors...6 Cables.8 Backplane Assembly 11 3

2.5 HDD 8-Port 6Gb/s Backplane 80H10323406A0 Revision History Date Modifications Jan / 03 / 2011 First release 4

2.5 HDD 8-Port 6Gb/s Backplane 80H10323406A0 6Gb/s Backplane Specification p/n : 80H10323406A0 Host Interface HDD Interface Hot-Swap (SFF-8087) SAS (22+7) and SATA-II compatible Yes, allows user to replace HDD on line LED indicates HDD status (Defined by Chenbro) Display Power LED Blue ( When HDD is present ) Access LED Green (When HDD is busy ) Error indicator Red (Error when retreating signals ) Cooling N/A 1. SFF-8087 x 2 to host 2. SAS (22+7) x 8 (for 2.5 HDD ) Connectors 3. Standard 4P Power connector x2 (+5V & +12V from power supply) 4. Pin header 2.54mm (2x4) *2 5. Pin header 2.0mm (1x2) *1 Dimension Material 137(L) x 81.7(W) x 2.4(H) mm FR4 6 layer Accommodation Chassis RM235XX RM417XX RM418XX 5

2.5 HDD 8-Port 6Gb/s Backplane 80H10323406A0 Backplane Layout Backplane Connectors Front View CN11 CN21 CN31 CN41 CN51 CN61 CN71 CN81 Rear View CB2 CN02 CN01 CB1 F0508 SW1 F0104 JP1 (1) [CN11 / CN21 / CN31 / CN41 / CN51 / CN61 / CN71 / CN81 ] : Connect to 22-pin SATA-II or 29-pin SAS HDD (2) [CN01 / CN02 ] : Power Connector (3) [JP1 ] : Auto Detect Function (4) [F0104] : HDD Failure LED Signal Pin Header for HDD 1 ~ 4 6

2.5 HDD 8-Port 6Gb/s Backplane 80H10323406A0 Pin Pin Descriptions NO. NO. Descriptions 1 HDD Fail LED (CN11) 2 Not Used 3 HDD Fail LED (CN21) 4 Not Used 5 HDD Fail LED (CN31) 6 Not Used 7 HDD Fail LED (CN41) 8 Not Used (5) [F0508] : HDD Failure LED Signal Pin Header for HDD 5 ~ 8 Pin Pin Descriptions NO. NO. Descriptions 1 HDD Fail LED (CN51) 2 Not Used 3 HDD Fail LED (CN61) 4 Not Used 5 HDD Fail LED (CN71) 6 Not Used 7 HDD Fail LED (CN81) 8 Not Used Connect the 4-pin HDD LED cable (26H113322-001) from F0104 / F0508 to the CATHODE of the HDD failure connector on RAID card. Refer to the RAID card s user manual for the detail pin definition. (6) [SW1] : SGPIO Function Switch ON OFF SW1-2 HDD Failure Signal via Port Enable HDD Failure Signal via Port Disable SW1-1 HDD Access Signal via Port Enable HDD Access Signal via Port Disable Default Setting SW1-1 HDD Access Signal: When switch to OFF, HDD access LED still can work via SATA-II HDD applied SW1-2 HDD Failure Signal: When switch to OFF, connect F0104 / F0508 to RAID / HBA to active HDD failure LED on backplane by LED cable 7

2.5 HDD 8-Port 6Gb/s Backplane 80H10323406A0 (6) [JP1] : Auto Detection Jumper For SAS or SATA HDD Jumper Closed: Enable Auto Detection (Default) Jumper Opened: Disable Auto Detection (7) [CB1 / CB2 ] : connector, Pin Definition See Below Information (8) [CN03 ] : Not Open To User Pin Definition: SFF-8087 36-pin cable plug and receptacle connectors B1 B18 B18 A18 A1 A18 Sideband Definition: The following table defines the SGPIO signal assignments for the receptacle connector Pin Number Pin Signal A8 Sideband 0 SClock A9 Sideband 1 SLoad A10 Sideband 2 Ground B9 Sideband 3 Ground B10 Sideband 4 SDataOut B11 Sideband 5 SDataIn A11 Sideband 6 Reserved B8 Sideband 7 SGPIO Enable / Disable 8

2.5 HDD 8-Port 6Gb/s Backplane 80H10323406A0 6Gb/s Cables The backplane provides most benefits to users using the same backplane to support various SAS/SATA RAID card via different conversion cables. Chenbro provides various cables for different interfaces which include the followings: (A) (B) (C) (D) (E) (F) 9

2.5 HDD 8-Port 6Gb/s Backplane 80H10323406A0 Table of cable solution Cable Connector Type BP side Host side P/N Length A Infiniband / Multilane (SFF-8470) 26H113215-011 600 mm B1 26H113215-012 600 mm B2 (SFF-8087 36pin R/A) 26H113215-019 600 mm B3 26H114612-001 350 mm C1 C2 SATA-7Pin x4 26H113215-010 600 mm SATA-7Pin x4 R/A 26H113215-017 600 mm C3 SATA-7Pin x4 26H113215-009 450 mm, 500 mm 650 mm, 750 mm D Wide-Port SAS (SFF-8484 R/A) 26H113215-013 600 mm E Wide-Port SAS (SFF-8484) 26H113215-016 600 mm F SATA-7Pin x4 Infiniband/Multilane (SFF-8470) 26H113215-015 450 mm, 500 mm 650 mm, 750 mm G (SFF-8087 26pin) 26H113215-018 600 mm H Wide-Port SAS 450 mm, 500 mm SATA-7Pin x4 26H113215-020 (SFF-8484) 650 mm, 750 mm Note: (1) Each BP requires one of cables above (A)~(E) (2) Cable-C3, F & H are for 4port SATA2/SAS BP with Multilane RAID card 10

2.5 HDD 8-Port 6Gb/s Backplane 80H10323406A0 Backplane Assembly The Chenbro 8-Port 6Gb/s Backplane can be assembled on Chenbro HDD Cage For Modular Storage Server Chassis only. Please refer to the Chassis Quick Installation Guide for detail information. Figure 1: 2.5 HDD Cage Front View Figure 2: 2.5 HDD Cage Rear View ( 3 pcs 8-Port Backplanes) Figure 3: 2.5 8-Port Backplane Assembly 11