100mm Process Indicator Recorder

Similar documents
/8 DIN Universal Process Indicator

Wall-/Pipe Mounted Universal Process Indicator

/8 DIN Motorized Valve Controller

C160 Wall-/Pipe Mounted Universal Process Indicator

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

Inform IT Single Pen Circular Chart Recorder

Universal Process Controller

FICHA TÉCNICA DE PRODUTO

FICHA TÉCNICA DE PRODUTO

Control IT. /16 DIN Controller/Alarm Unit. Data Sheet SS/C50_7 C50. C50 the 1 /16 DIN controller to suit your simplest applications

Inform IT 250mm Multipoint Strip Chart Recorder

Control IT Booster Pump Controller

250mm Advanced Process Recorder

C /4 DIN Multi-Recipe Profile Controller. C360 a comprehensive profile controller for all ramp/ soak applications

C1900 Series Circular Chart Recorder. C1900 a rugged, reliable recorder with the full capability to meet your needs

C1300 Advanced Circular Chart Recorder. C1300 dependable recording in a rugged, functional instrument

ABB MEASUREMENT & ANALYTICS DATA SHEET. C1300 Advanced circular chart recorder

ABB Instrumentation. Specification DataFile. COMMANDER 1900 a rugged, reliable recorder with the full capability to meet your application needs

C1300 Advanced Circular Chart Recorder. C1300 dependable recording in a rugged, functional instrument

ABB Instrumentation. Multipoint Chart Recorder COMMANDER SR250B. Specification DataFile

ControlMaster CM15 Universal process indicator, 1 /8 DIN. Making process control easy

ControlMaster CM10 Universal process controller, 1 /8 DIN. Making process control easy

ABB Instrumentation. Specifications. COMMANDER 505 Advanced Process Controller

Inform IT Circular Chart Recorder/ Controller

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

Inform IT 100mm Advanced Process Recorder

DPR 100 A/B Analog Scales

MODCELL 2050R Single Loop Controllers

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

/2 DIN Advanced Process Controller

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Pasteurizer Recorder and Recorder Controller

Strip Chart Recorders Specification Sheet

Replacement Parts and Upgrade Kits for C1900 and C1300 Circular Chart

DINALOG A 144 x 36 A1400 Light-Strip Indicator

THM501 PT100 MODBUS TEMPERATURE TRANSMITTER

The CAL range of temperature controllers

Indicomp 4 Bargraph Indicator

ABB MEASUREMENT & ANALYTICS DATA SHEET. ControlMaster CM10 Universal process controller, 1/8 DIN

/4 DIN Advanced Process Controller

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

ABB Instrumentation. Advanced Process Controller COMMANDER 505. Specification DataFile

ControlMaster CMF160 Universal process indicator, fieldmount

Replacement Parts and Upgrade Kits for C1900 and C1300 Circular Chart

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

C1950 (STLR & HTST) Pasteurizer Recorder and Recorder Controller

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

LineMaster 100 Continuous-line Recorder

Specification DataFile

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

SX90 Process Controller

ABB Instrumentation. Specification DataFile. COMMANDER 355 advanced single loop controller in a short case, 1 /4 DIN format

Trident and Trident X2 Digital Process and Temperature Panel Meter

ControlMaster CM30 Universal process controller, 1 /4 DIN. Measurement made easy. Making process control easy

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

PD765 TRIDENT. Trident Series Process & Temperature Meters.

UNIVERSAL TEMPERATURE TRANSMITTER

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

HART UNIVERSAL TEMPERATURE TRANSMITTER

Basic Temperature and Limit Controllers. Provide Economical Solution for a Wide Range of Applications SPECIFICATION SHEET

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

PD765 TRIDENT. Trident Series Process & Temperature Meters.

HIGH-VOLTAGE DC METER

DIGITAL INDICATING CONTROLLER

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

Analyze IT Analytical Instruments Two-Wire ph, ORP, plon Transmitters

High Voltage DC Meter

HART UNIVERSAL TEMPERATURE TRANSMITTER

LAUREL ELECTRONICS, INC.

ControlIT Process controller

SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER

Field Mountable Videographic Recorder

LineMaster 100. Continuous-line Recorder. ABB Instrumentation 10/ EN

ScreenMaster RVG200 Paperless recorder

HIT/HIX HART Isolator

Inform IT Advanced Videographic Recorder

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

ABB MEASUREMENT & ANALYTICS DATA SHEET. C1950 (STLR & HTST) Pasteurizer recorder and recorder / controller

Basic Temperature and Limit Controllers

PXR Series Advanced Self-Tuning Temperature and Process Controllers

Temperature Measurement

ScreenMaster RVG200 Paperless recorder. Measurement made easy. Secure process data at your fingertips

Printing recorder with text printing and 24-character LED dot-matrix display. Brief description. Overview of functions. Features

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

AMC8 and IOC8T Analog monitoring card and input / output card

Digital Indicator DS 48/24 E

Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW

DI-924MB. Thermocouple/Millivolt Input Module

ControlMaster CM10, CM30 and CM50 Universal process controllers, 1 /8, 1 /4 and 1 /2 DIN

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

ControlMaster CM30 Universal process controller, 1 /4 DIN. Making process control easy

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

Power Meter PowerMonitor 500

DIGITAL STRIP CHART RECORDER PRODUCT MANUAL

itemp TMT180 Technical information

Power supply CP-C 24/5.0

Transcription:

Data Sheet SS/_3 100mm Process Indicator Recorder One or two pen continuous line 100mm recorder universal input for thermocouple, RTD, mv, ma and V Clear, 5-digit LED display high visibility, wide viewing angle Two (5A) alarm relays as standard allocated to individual channels or common to both Isolated analog retransmission easy connection to management system Two digital inputs chart start/stop, change chart speed or remote alarm acknowledge Configuration from front fascia or via PC simple configuration setup and storage procedure Transmitter power supply power each loop from the standard unit, no extras needed IP65/NEMA3 protection reliability in the harshest environments combination of a high resolution process indicator and a compact chart recorder

SS/_3 The is a one or two pen continuous-line 100mm strip chart recorder with a number of features included as standard: Two alarm relays Isolated analog retransmission Two digital inputs Transmitter power supply. These inbuilt features make the an extremely versatile chart recorder. It has a bright, 5-digit LED display giving clear indication of the process. Configuration using the front keys is very easy. The can also be configured using the PC Configuration software increasing the flexibility and reducing setup time. With a IP65/NEMA3 front fascia the is suitable for use in harsh industrial environments. Process Connections Isolated Universal Process Input Thermocouple RTD 4 to 20mA Volts, Millivolts Tx Power Supply Single Pen Two Pen Isolated Universal Process Input Thermocouple RTD 4 to 20mA Volts, Millivolts Tx Power Supply Roll Chart or Fanfold Chart 5-digit LED display 2 Digital Inputs Two Relays Analog Retransmission Standard Optional PC Configuration 2

SS/_3 Clear Display and Simple Controls Process values and alarm messages are shown on the highresolution 5-digit LED display which has been designed for maximum visibility. On the two-pen version the display toggles between input one and input two. Beneath the display are 6 keys (increment, decrement, scroll, multifunction, pen lift and chart speed selection) that are used to operate and configure the recorder. The instrument is equipped with four user-defined alarms, each with its own LED which is lit when an alarm condition exists. Extras Built-in as Standard To meet the majority of process needs, two relays are included in the standard build. These can be allocated as one per channel, both on one channel or common to both channels. Further flexibility is provided by an analog retransmission signal and two digital inputs. The digital inputs can be used for remote acknowledgement of alarms, starting and stopping the chart or for changing the chart speed. All this as standard makes the an extremely versatile recorder. Isolated Universal Analog Inputs Both of the analog inputs are universal, galvanically isolated and accept direct connection from all standard thermocouple, RTD, ma, mv and voltage sources. Using the PC Configuration software, non-standard ranges as low as 5mV are also possible. The recorder also has a 2-wire transmitter power supply suitable for powering each loop. 3

SS/_3 Easy Setup The can be configured in one of two ways: Front face keys The front face keys are used to configure the instrument via a security code protected configuration menu. PC Configurator The standard equipment PC configurator port is used to connect a PC equipped with the Windows -based PC Configurator software making setup a point-and-click operation. Settings can also be saved on the PC and copied to other recorders making setup of multiple instruments quick and simple. Rugged Enclosure Design The case has been designed to withstand operation in harsh industrial environments with IP65/NEMA3 front face protection as standard. This makes the instrument ideal for use in food applications and hosedown areas. 4

COMMANDER COMMANDER COMMANDER COMMANDER 100mm Process Indicator Recorder SS/_3 Applications Temperature Monitoring The compact design of the makes it ideal as a local temperature monitor and alarm. Inbuilt CJ compensation enables the direct connection of all standard thermocouples. For precision measurement Pt100 resistance thermometers can be connected directly via the universal input, thus ensuring low installation costs. The clear LED display provides highly visible indication and numbered alarm LEDs provide instant process status verification. Environmental/Laboratory Monitoring The unbroken line on the chart provided by the is ideal for continuous gas or liquid environmental applications. Other uses include batch monitoring of laboratory tests, or test chambers, to verify the test results and the provision of alarm signals to indicate if a test exceeds preset limits. Discharge Monitoring With universal inputs the provides the opportunity for local monitoring and alarms for the measurement of parameters such as level, flow and ph. The retransmission also provides the ability to retransmit this signal to a process monitor so readings can be integrated into a plant data acquisition scheme. Indicating Recorder Ideal for small units or operator panels providing clear, high resolution digital indication of process variables. 360.0 360.0 360.0 360.0 The cost-effective price of the allows individual indication,with sensitivity down to 10V, or 0.2C (0.11F), and a secure hard copy record for traceability of the process. 5

SS/_3 Specification Summary 1 or 2 continuous lines 100mm wide roll or fanfold chart Fully user-programmable IP65/NEMA3 protection Recording Measuring channels 1 or 2 Colors Single continuous line, Red Two continuous lines, Pen 1 Red, Pen 2 Green Chart 7.5 m fanfold or 15m roll Quick-load cassette Standard chart graduation 50 divisions Chart speed Configurable in 1mm steps between 1mm and 1500mm/hr Logic or switch selectable at two configured speeds Pen response time 4s, 10 to 90%, typical Operation Display High intensity 5-digit LED display (14mm high) Configuration User-defined via front panel or Windows-based PC configurator Alarms Number Types Hysteresis Accuracy Pen Resolution 4 user-defined High/Low process High/Low latch Programmable level 0.2% of span Display Display range 9999 to +99999 Display resolution 1digit Digital Inputs Number 2 Type Volt-free contacts Minimum pulse 250ms Outputs Retransmission Analog configuration in the range of 4 to 20mA Max. load 15V (750 at 20mA) Accuracy 0.25% of span Isolation 500V DC from inputs Assignable to any one analog input Relay Outputs 2 relays (SPDT) 5A at 115/230V AC Assignable to alarms Physical Size 144mm (5.67 in.) x 144mm (5.67 in.) x 230mm (9.05 in.) depth behind panel Weight 3.3kg (7 lbs) approx. Panel cut-out 138mm (5.43 in.) x 138mm (5.43 in.) Case material Sheet steel case, stove enamel painted Door material Glass-filled polycarbonate Window material Polycarbonate Electrical Power supply 85 to 265V 50/60Hz Power consumption 36W max. Electrical safety EN61010-1 CE marked instruments meet EU regulations CSA (optional) Electrical connections Screw terminals 6

SS/_3 Environmental Operating limits 0 to 50C (32 to 122F) 95% RH non-condensing 80% RH for chart Temperature stability 0.02% of reading or 2V/C whichever is the greater Protection Front face IP65 NEMA3 Rear of instrument IP20 Line interruption <80ms loss, no effect >80ms loss, auto reset and restart EMC Emissions and Immunity Meets requirements of IEC 61326 for an Industrial Environment Design and manufacturing standards Designed to meet CSA requirements CE mark Analog Inputs Number 1 or 2 isolated analog inputs Input sampling rate 250ms Input Type Universally configurable to provide: Thermocouple (THC)* Resistance thermometer (RTD) Millivolt Current DC voltage *2 nd input can be THC, but only if 1 st input also THC Linearizer functions Programmable for: Filter time Broken sensor protection Upscale drive on THC and RTD Downscale drive on ma and voltage Square root THC types B, E, J, K, N, R, S, T or Pt100 Adjustable up to 60s Cold junction compensation (CJC) Automatic CJC incorporated as standard Accuracy <0.05% C/C change in ambient Input impedance ma mv, V 100 >10M Transmitter power supplies Two isolated supplies 25mA max. each Input isolation Analog channel-to-channel isolation 500V DC Input to ground 700V DC Common mode >120dB at 50/60Hz with 300 imbalance resistance Series mode >60dB at 50/60Hz 3-lead RTD Max. lead resistance 10 7

SS/_3...Specification Standard Analog Input Ranges Thermocouple Maximum Range C Maximum Range F Accuracy (% of reading) * B 18 to 1800 0 to 3270 2C (above 200 C) E 100 to 900 140 to 1650 0. 5C J 100 to 900 140 to 1650 0. 5C K 100 to 1300 140 to 2350 0. 5C N 200 to 1300 325 to 2350 0. 5C R 18 to 1700 0 to 3000 1. 0C (above 300 C) S 18 to 1700 0 to 3000 0. 5C (above 200 C) T 250 to 300 400 to 550 0. 5C * Performance accuracy is not guaranteed below 400ºC (752ºF) for B, R and S thermocouples M in. span below zero Type T 70ºC (126ºF) Type N 105ºC (189ºF) THC standards DIN 43710 IEC 584 RTD Maximum Range C Maximum Range F Accuracy (% of reading)* * Pt100 200 to 600 325 to 1100 0. 5C ** RTD, 3-wire platinum, 100 per DIN43760 standard (IEC751), with range of 0 to 400 Linear Inputs R ange Accuracy (% of reading) Milliamps 0 to 20 2A Milliamps 4 to 20 2A Volts 0 to 5 2mV Volts 1 to 5 2mV Millivolts 0 to 50 20V Square Root Input R ange Accuracy (% of reading)** * Milliamps 4 to 20 2A *** Below input of 4.64mA (20% flow) the input is linear 8

SS/_3 Overall Dimensions Dimensions in mm (in.) 144 (5.67) 20 230 (9) 13 +0.8 0 +0.03 (5.43 0 ) 222 (8.75) 144 (5.67) Panel Cut-out 13 +0.8 0 +0.03 0 (5.43 ) Electrical Connections Terminal blocks viewed from rear of case NO C NC NO C NC Relay 1 Relay 2 Fuse (1A anti-surge) Line Neutral Tx PSU (+) + 3 rd Lead RTD Analog Input 2 (CR102 only) Tx PSU (+) + 3 rd Lead RTD Re-Tx Output+ Re-Tx Output Analog Input 1 Digital Input 1 Digital Input 2 Digital Input Common 9

SS/_3 Ordering Information 100mm Process Indicator Recorder C R10 X/ X X X X/ Number of Pens Build Door Single pen Two pens ABB Standard CSA approval (pending) Without lock 0 Chart Drive Roll chart Fan-fold chart Power Supply 85 to 265V AC 1 Programming/Special Features Configured to factory standard Configured to customer requirements Special features 1 2 B C 1 2 X X X X S T D C U S S P X X Accessories PC Configurator kit (part no. C100/0700) 10

SS/_3 Standard Chart Selection Range International *Supplied as standard Note. Other ranges may be available on request. R oll Chart Part No. Fanfold Chart Part No. North America 50/+50 P100L/7477G KPC100-1110 0/14 P100L/17463G KPC100-1047 0/50 P100L/7401G KPC100-1032 0/100* P100L/7400G KPC100-1037 0/150 P100L/7414G KPC100-1039 0/200 P100L/7420G KPC100-1040 0/500 P100L/7010G KPC100-1043 0/800 P100L/17446G KPC100-1045 0/1000 P100L/7476G KPC100-1072 International North America P100L/7477X KPC100-8042 P100L/17463X KPC100-8032 P 100L/7401X P100L/7400X KPC100-8034 P100L/7414X KPC100-8050 P100L/7420X KPC100-8051 P100L/7010X KPC100-8058 P100L/17446X KPC100-8064 P100L/7476X KPC100-8037 Licensing, Trademarks and Copyrights MS Windows is a trademark of Microsoft Corporation Modbus is a trademark of Modicon, Inc. 11

SS/_3 ABB has Sales & Customer Support expertise in over 100 countries worldwide www.abb.com The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in UK (05.05) ABB 2005 SS/ Issue 3 ABB Limited Howard Road, St Neots Cambridgeshire PE19 8EU UK Tel: +44 (0)1480 475321 Fax: +44 (0)1480 217948 ABB Inc. 125 E. County Line Road Warminster PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183