E-Access ANXELL TECHNOLOGY CORPORATION E3AK4 E3AK2. Specifications Voltage (Input): 12 to 24 VDC

Similar documents
DG Series. Access Control Proximity Readers DG-160 DG-800

Specifications: Features:

212iL Rev. 1.1

SK-1011-SDQ Access Control Keypad. Manual

SK-1011-SQ Digital Access Keypad with 5A Relay Output

Digital Keypad Introduction

Waterproof. Keypad/Reader/Controller

CM-110SK Standalone Keypad Installation Instructions

HL100 Fingerprint Lock User Manual

ENFORCER SK-1131-SQ. Digital Access Keypad with 5A Relay Output MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

Outdoor Stand-Alone Weatherproof Keypads

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

SA-027WQ. Manual. 7-Day Timer. Lighting Systems Access Controls Security Systems Environmental Controls. Automate the following:

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

W3-M. Metal waterproof standalone access control/reader. User Manual

BC Digital Keypad. User Manual

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

W3-H Waterproof Keypad/Reader/Controller

Single Door Standalone Access Control User Manual

DP-222Q Color Video Door Phone Manual

SK-1131-SPQ Access Control Keypad with Proximity Card Reader. Manual

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

232iLM Keypad Installation and Programming Instructions

DP-236Q. Manual. Wireless Video Door Phone

DOLXFD1000B. Waterproof Access Control/Reader

1x Battery Cover PART #KYPT-02. 2x Backup Keys PART #KYPT-03 3x Phillips Head Screws PART #KYPT-04

DP-234Q (NTSC) DP-734Q (PAL) Hands-Free Video Door Phone Manual

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Fingerprint Access Control F1. User Manual

USER MANUAL TEMPLATE ELECTRONIC DEADBOLT LOCK

Installers & User guide Smart Mortise.

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

EL-ST100 KEYPAD CONTROLLER

Installers & User guide Smart Mortise.

Enter a new user. code. Enter. Enter a 2-digit user ID. Enter a user code. (from 00~09) (from 00~09) Enter

WiFi Video Doorbell. User Manual

User Manual. PCKeypad Wireless Keypad

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

CP150B Vandal & Weather Resistant Keypad Security Systems

User Manual. Smart Lock. Please read this manual before operating your Smart Lock, and keep it for further reference. 40

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

DP-222Q Color Video Door Phone Manual

Installation and User Manual

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

Installing Keypad and Backplate

WiFi Wireless Video Door Phone. User Manual

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

1. Product Specification

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

CLICK HERE FOR ACCESS

INSTRUCTION MANUAL AC-T43 PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT. 07/04

Installers & User guide Deadbolt 2S.

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

K-PROX Series INSTALLATION & INSTRUCTION MANUAL. Essex Electronics, Inc KEY-LESS fax keyless.com

RBR-SB-KTZ001 LAR 2. User Manual

Welcome Contents Diagram

-DTZ001- Stand-Alone Proximity Access Control. User Manual

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Revision Date: 02 Mar 2018

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

703 F o u r B u t t o n D E C T I n t e r c o m

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01

DG-800 Stand-Alone Proximity Reader Instruction Manual

Bluetooth Lock Boxes User Guide

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

ENFORCER. SK-1123-SQ Outdoor Digital Access Keypad with 2 Outputs MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices

Wireless Doorphone Intercom

Pro-Access Module Trident Laundry Chemical Delivery System

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

RFID/Digital Access Control Keypad

Installation Manual AV2245PM-W AV2246PM-W AV3245PM-W AV3246PM-W AV5245PM-W AV2245PM-D AV2245PM-D-LG AV2246PM-D AV2246PM-D-LG AV3245PM-D AV3245PM-D-LG

Operation manual For NG BIOSINGLE Version 1.1

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasIED.com

WELCOME. For customer support or any inquiries, please visit our web site at or contact us at

K44 Code lock. Technical manual

WiFi Wireless Video Door Phone. User Manual

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

VITEK VTC-TNB8RFS. Transcendent Series 8 Megapixel H.265 Indoor/ Outdoor WDR IP Bullet Camera with 36 IR LED Illumination QUICK START GUIDE

User Manual. Split access control with intelligent secured power supply.

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

Security at Fingertips.

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

SETUP GUIDE INSTALLATION HANDBOOK. For Integrators, Installers and Administrators. Everything on how to get Kisi up and running. getkisi.

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

i30 SIP Video Door Phone Quick Installation Guide

QuickTouch (QT4) Owner s Manual

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

Copy Machine Reader. Installation and Setup Guide

XP-KIT. Programming & Operations. Programming Starter Kit for Aiphone -XP Series Proximity Reader Stations

ML-10B. Fingerprint Lock with Voice Guide Feature. Admin & User Guide

MS-7000: SuperStar Reader

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions

SVT-WIFI Video Intercom System C

DP-266-1C3Q Wireless Video Door Phone

Transcription:

E-Access E3AK1 E3AK2 E3AK3 E3AK4 4-3/4" x 2-15/16" x 1-13/16" (120 x 74 x 46.2 mm ) 4-1/2" x2-3/4" x1-5/8" (114 x 70 x 41 mm) 4-13/16" x 3" x 2-1/2" (123 x 77 x 64.2 mm) 3-7/16" x 3-7/16" x 1-3/4" (87.3 x 87.3 x 45.2 mm) eatures 1 Administrator, 1000 users 2 Access Modes: Use Bluetooth smartphone or enter 4 to 8 digit Passcode to access Built-in tamper alarm and buzzer 85dB User Management: Add/delete/view user data, grant user access for specific dates or time periods, change user passcode, or enable/disable user keypad entry Audit rail logs for last 1000 events he keypad will be disabled for one minute when 3 failed passcode attempts. Specifications Voltage (Input): 12 to 24 VDC Current Draw: Standby current: 16mA@12VDC, 7mA@24VDC Working current: 18mA@12VDC, 9mA@24VDC Bluetooth module: BLE 4.2 Operating distance : Up to 50 meters(164 ft) without blocking by metal or concrete wall/door frame. Smartphone Compatibility: Android 5.0 to 8.0, ios 9.0 and up inishes/colors: Dark Brown or Navy No.304, Xinshu Rd., Xinzhuang Dist.,New aipei City 242, aiwan (R.O.C.)

E3AK Installation Instructions E3AK1 Installations 1 2 Anchor bolts x4 x 4 russ head phillips screws 3/16" x 1"(4 x 26mm) Spanner screws 3/16" x 1/2" (4 x 13 mm) Install the surface mount box using 4 truss head phillips screws and the anchor into the wall. Connect the wires and mount the keypad cover to the box with 2 spanner screws. inish installation. E3AK2 Installations 1 2 Anchor bolts x4 x 4 russ head phillips screws 3/16" x 1"(4 x 26mm) Cover caps x4 lat head phillips screws x2 3/16" x 1/2"(4 x 12mm) Install the surface mount box using 4 truss head phillips screws and the anchor into the wall. Connect the wires and mount the keypad cover to the box with 2 flat head phillips screws. Insert the cover caps and finish installation. E3AK3 Installations 1 2 Anchor bolts x4 russ head phillips screws 3/16" x 1"(4 x 26mm) Spanner screws x2 3/16" x 1" (4 x 26mm) Install the surface mount box using 4 truss head phillips screws and the anchor into the wall. Connect the wires and mount the keypad cover to the box with 2 spanner screws. inish installation. No.304, Xinshu Rd., Xinzhuang Dist.,New aipei City 242, aiwan (R.O.C.)

E3AK Installation Instructions E3AK4 Installations 2-9/16 (65mm) 1 2 2-3/8 (60mm) russ head phillips screws x 4 3/16" x 1"(4 x 26mm) 5/16 (8.5mm) 3/16 Ø4 3/8 Ø10 3/16 Ø4 2-1/8 (53.5mm) Pan head phillips screws x 2 3/16" x 1-3/16" (4 x 30mm) 5/16 (8.5mm) Cover caps Anchor bolts x4 Position the template onto the wall and then drill a center hole cable access and 4 mounting holes. Dimensions Install the base plate using 4 truss head phillips screws, and then mount the keypad cover with 2 pan head phillips screws. Insert the cover caps and finish installation. * Use the pan head phillips screw - cone point when installing the device without the base plate. E3AK1 11/16 (17mm) 2-15/16 (74mm) 1-7/16 (37mm) E3AK2 1-5/8 (41mm) 2-3/4 (70mm) 3-5/16 (83.5mm) 4-3/4 (120mm) 4-1/2 (114mm) 1-13/16 (46.2mm) E3AK3 2-1/2 (64.2mm) 3 (77mm) E3AK4 3-7/16 (87.3mm) 3-5/16 (83.5mm) 4-13/16 (123mm) 3-7/16 (87.3mm) 2-1/8 (54.5mm) 2-3/8 (60mm) 1-3/4 (45.2mm) No.304, Xinshu Rd., Xinzhuang Dist.,New aipei City 242, aiwan (R.O.C.)

E3AK1, E3AK2, E3AK3, E3AK4 Wiring Diagrams Reset Procedures Buzzer BLE 4.2 Module Reset Button Door Exit Sensor Button VIN NO COM NC Exit Button Door Sensor Polarity Insensitive PSU Electrified Lock 1 (ail-safe) Electrified Lock 2 (ail-secure) How to Reset a Bluetooth Keypad with Reset Button on the PC board? 1. Power off Access Control Keypad/Reader. 2. Press and hold the Reset Button, then power on. 3. Hear a long beep to complete resetting procedures. 4. Login as Admin and check all users, audit trail events are all cleared and all data is reset to factory default setting, except device name and device time. Crimp connectors included: Crimp Connector Use a pair of crimping pliers designed to crimp insulated connectors. Place the crimp connector into the compression slot. Be sure the crimping jaws are positioned over the stripped portion of the wire. Squeeze the handles together with enough force to crush the end of the butt splice. Screw Packages E3AK1 Screw Pack x2 x1 E3AK2 Screw Pack x2 x4 or All E3AK Screw Packs x4 Security Screw 4 x 13mm Spanner screwdriver lat head phillips screw (Spanner flat head screw) 4 x 12mm Cover cap Anchor bolt x10 E3AK3 Screw Pack Security Screw 4 x 26mm (Spanner flat head screw) E3AK4 Screw Pack x2 x1 x2 x4 Spanner screwdriver Pan head phillips screw, lat point 4 x 30mm Cover cap Crimp Connector x4 russ head phillips screw 4 x 26mm LED & Audible Indicators LED Solid Blue Blue lashing Green Red Keypad Status Power on, Standby mode Bluetooth is connecting Unlocked, Door always unlocked Invalid Access, Door always locked Audible Beeps Status 1 Short beep Key press 1 Long beep Valid Access, Reset is completed 2 Short beeps Login completed 3 Short beeps Constant beeping Incorrect Passcode, Login failure, orget to press # after entering Passcode within 30 seconds. Bluetooth keypad vandalized, Door Sensor is ON No.304, Xinshu Rd., Xinzhuang Dist.,New aipei City 242, aiwan (R.O.C.)

E3AK APP (a) Download E3AK APP App Store E3AK Download the E3AK APP to set up. Scan QR code on the left or go to Apple Store or Google Play depending on what kind of smartphone you use. (b) E3AK App for Administrator and Users 1 2 3 Press to go to Devices page. Select the designated Bluetooth device as shown on Login first, Administrator : Enter Admin ID and Admin Passcode to login. Default Admin ID: ADMIN Default Admin Passcode: 12345 User : Enter User ID and User Passcode to login. User ID and User Passcode are given by the Administrator. [Note] 1. Administrator ID ADMIN can not be changed. we recommend changing Admin s default passcode 12345 right after you login as the Admin. Go to settings page, tap Admin Passcode to Edit Admin Passcode. 2. Admin passcode and User passcode are also used as keypad Passcode access. (c) Administrator Settings Page 1 2 Press to go to "Settings" page as shown. (d) Administrator Settings Page Users Management Add / Delete / Edit User Information Press "Users" to edit individual user's information. You can add a user, delete a user, and select individual user to give specific settings. No.304, Xinshu Rd., Xinzhuang Dist.,New aipei City 242, aiwan (R.O.C.)

E3AK APP Administrator Settings Page Introductions : Users Audit rail Backup Data Restore Backup You can Add / Delete / Edit user information. Audit rail is tracking last 1000 event logs, including amper Alarm. Audit rail can be exported in an excel file. ap to export all events to excel file. ap to refresh all events. Backup Data is to backup all data to Administrator's phone and can be restored except Device Name, Audit rail logs and Device ime. You can restore the last backup data to a new Access Control Keypad / Reader. Device Name Admin Passcode Door Sensor Lock Action Device name can be edited as a model number, Office, ront door, Gate, etc. 12345 is Admin default passcode. It s important to change your Admin passcode immediately. You can enable Door Sensor when you connect to a closed-circuit magnetic sensors or a monitored door lock that has door sensor (or lock sensor) outputs to monitor the open or closed state of a door. 3 options. You can choose Door Re-lock ime, Door Always Unlocked and Door Always Locked. amper Alarm Door Re-lock ime Device ime About Us amper Alarm is deactivated by default. You can activate amper Alarm. If the device is vandalized, the tamper alarm will howl immediately and won t go off until it s switched off by Administrator. You can set the door re-lock time interval between 1 to 1800 seconds. Make sure to set up Device ime precisely as your current time zone of where you are. It helps having correct and precise access data and information. ap About Us to show Device Model, APP version, website and E-Mail information. No.304, Xinshu Rd., Xinzhuang Dist.,New aipei City 242, aiwan (R.O.C.)

E3AK APP Administrator Settings Pages Users Management Edit User Information ID PASSCODE Keypad Access ap user ID to Edit ID. ap user PASSCODE to Edit PASSCODE. You can enable/disable keypad access for a user. Access ypes emporary ap "Access ypes" to choose Permanent, emporary, Number of imes, or Scheduled. he App is set to give Permanent access by default. ap emporary to set specific access time periods. Number of imes Scheduled ap Number of imes to set number of access granted to user. ap Scheduled to assign repeatedly access on specific days and hours for a certain period of time. his setting is useful for house cleaners and other guests that need temporary access on regular basis. No.304, Xinshu Rd., Xinzhuang Dist.,New aipei City 242, aiwan (R.O.C.)

E3AK APP Auto Proximity Range Adjustment and Auto unlock unction Administrator Interface: 1 4 2 3 5 6 figure 1 ap to go to Device list page as. figure Select the desired Bluetooth Access Control Keypads/Readers around you. ap 4 Settings button to go into Settings page as figure 3 to select Proximity Read Range figure Adjust Auto Proximity Range for Auto unlock function between 0 to 20. figure Back to the main page. ap Auto to enable Auto unlock function to access. Auto Proximity Range Adjustment and Auto unlock unction User Interface: 1 4 2 3 5 6 figure 1 ap 1 to go to Device list page as 2. figure 2 Select the desired Bluetooth Access Control Keypads/Readers around you. ap 4 Settings button to go into Settings page as figure 3 to select Proximity Read Range figure 5 Adjust Auto Proximity Range for Auto unlock function between 0 to 20. figure 6 Back to the main page. ap Auto to enable Auto unlock function to access. Note: Make sure to disable Auto before pressing to enter Settings page. No.304, Xinshu Rd., Xinzhuang Dist.,New aipei City 242, aiwan (R.O.C.)

E3AK Operation Instructions Note: Stand next to the E3AK Bluetooth keypad when you want to connect the Smartphone to unlock or login, the Bluetooth keypad can detect signal up to 50 meters (164 ft) distance. he response time of Bluetooth signal may vary depend on various mobile device models. Bluetooth range up to 50 meters (164 ft) Keypad Passcode Access After login is complete, you can enter your Passcode plus # to unlock the door. or example: If your passcode is 12345, enter 1 2 3 4 5 #. No.304, Xinshu Rd., Xinzhuang Dist.,New aipei City 242, aiwan (R.O.C.)

Warranty his ANXELL product is warranted against defects in material and workmanship while used in normal service for a period of one year from the date of sale. ANXELL s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to ANXELL. Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason ANXELL determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. NOICE: he information and specifications printed in this manual are current at the time of publication. However, the ANXELL policy is one of continual development and improvement. or this reason, ANXELL reserves the right to change specifications without notice. Copyright 2017. All rights reserved. his material may not be reproduced or copied, In whole or in part, without the written permission of ANXELL. No.304, Xinshu Rd., Xinzhuang Dist.,New aipei City 242, aiwan (R.O.C.)