CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. In-situ low cost, low maintenance devices for continuous process and emissions monitoring.

Similar documents
CO, NO, NO 2, NO x, SO 2, CH 4, HCl, N 2 O, CO 2 & H 2 O

Continuous Flow Monitoring

Multi-channel measurement technology to measure CO, NO & Visibility in one compact sensor

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

D-R300 / D-R320 / D-R 800 DATASHEET

Flow VA 500/

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_

Dräger Polytron 8200 Stationary gas detector (CatEx)

Digital electropneumatic Positioner for the integrated mounting on process control valves

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

TPE 1464 Series Pressure Transducer

CDD4 Duct Carbon Dioxide Transmitter

PROCESS ANALYSERS. SERVOTOUGH FluegasExact Gas Analyser. QuickStart Manual. Part Number: D Revision: 1 Language: UK English

2700 Combustion Gas Analyser

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

DMT345 and DMT346 Dewpoint Transmitters

Continuous Dew Measurement in Explosive Area for flammable and non-flammable gases. VASTHI ENGINEERS

Online data sheet DUSTHUNTER SB100 SCATTERED LIGHT DUST MEASURING DEVICES

Portable pressure calibrator Model CPH7600

O 2 SENSORS Zirconium Dioxide (ZrO 2 ) Sensor and Interface Selection Guide

DS 500 Intelligent chart recorder for compressed air and gases

C-Flow Coriolis Mass Flow Meter

D Issue A. Instruction Manual. Active Strain Gauge

TOXALERT MODEL AIR 2000

IDS 500 mobile Intelligent mobile chart recorder

Product Guide. Repeatable RH and temperature measurement for precise humidity control and validation

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Chart recorder. DS 500 mobile Intelligent mobile chart recorder

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours.

Online data sheet. FW101 Ex SCATTERED LIGHT DUST MEASURING DEVICES

Product Specification. tsense VAV. CO 2 -, Temperature- and RH- sensor in a housing with colour touch display

The SF-586b Insertion Flow Meter For Compressed Air, Gases And Exhaust Air (up to 400 C) In Pipe Diameters From 25mm to 5000mm

Microdust Pro Real-Time Dust Monitor

VPINSTRUMENTS.COM VPFLOWSCOPE M. Your next step in gas flow measurement

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

Digital Positioner 8049

... f l o w measurement & control...

A C C S for Road Tunnels. NOVICOM CO/NO/Visibility Monitor Contact us for Information about:

IDS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

High-speed peumatic pressure controller Model CPC3000

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

MID approval no. DE-08-MI004-PTB004 Date of release

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

Level and Flow Measurement. Flow Pulse

CDD4 Series Room CO2 Transmitter Installation Instructions

Explosion-Proof Gauge Pressure Transmitter

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service

Immersion Temperature Sensors

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410

Wall-/Pipe Mounted Universal Process Indicator

PI 500 Hand-held instrument for industry

Electronic pressure switch with display Model PSD-4

Endress Hauser CUM 740. Measuring Transmitter for Turbidity and Solids Content ISO The Power of Know How

LiquiDens. SensoTech. Process density meter for liquids Product description

C160 Wall-/Pipe Mounted Universal Process Indicator

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Pneumatic High-Speed Pressure Controller Model CPC3000

Analyser Control Unit Mk4. Operating Manual

BXD17 Series. Features. Analytical instrumentation for your measurement applications.

Model VDL 115 Vacuum drying chambers for flammable solvents

The industrial humidity transmitter

Industrial pressure controller Model CPC4000

Unique Compressed Air Management System. GD Connect 12. The perfect fit

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe

DUSTTRAK II AEROSOL MONITORS MODELS 8530, 8530EP AND 8532

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO.

SideControl Positioner

Flue Gas Analyzer. The Value Leader TM

Universal IV Water Cut Meter

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

Advanced Pump Controllers

EC 600 Electronic Volume Corrector

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

Performance and Efficiency

Thermal Mass Flowmeter Sensyflow FMT200-D

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

ATU800. Technical specification

CLEAN ROOM PANEL - CRP5

Level and Flow Measurement. Flow Pulse

Environmental Equipment, Inc.

analytical bulk flow distance FLOW level pressure temperature industrial communication

REFERENCE GENERATOR FOR CALIBRATION OF HUMIDITY AND TEMPERATURE INSTRUMENTS

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

PanaFlow Gas Meter System

Online data sheet DUSTHUNTER SB30 SCATTERED LIGHT DUST MEASURING DEVICES

Blackbox Controllers:

NEMA 7. Wireless Technologies USA Witech USA Corp

APPLICATIONS. Boiler / Burners Turbines Engines Incinerators Process Control Landfills Cogeneration plants

MCS 100 E. Compact IR Photometer for Stack Gas Monitoring

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours.

IRM-5000P. insulation resistance meter. Vanguard Instruments Company, Inc.

Transcription:

Product Data Sheet Continuous Emission Monitoring GCEM 40 Series Gas Analyser CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O In-situ low cost, low maintenance devices for continuous process and emissions monitoring. Single or Multi-species infrared absorption analyser - Accurate, reliable and low maintenance technology In-situ stainless steel probe measurement - Single unit install. No sample lines required Gas temperature and pressure sensors - On-board normalisation to standard reference conditions Auto routine calibration - Zero and span calibration using audit gas Analogue and serial outputs - Export of data to SCADA, DCS and historian systems

GCEM 40 Series Gas Analyser The GCEM40 series is the latest generation of s world renowned in-situ monitors. Our development, knowledge and practical experience have been utilised to produce this advanced technology gas analyser which gives complete flexibility of use on process or emissions applications whilst delivering superb accuracy and repeatability at a very competitive price. The analyser uses a field proven in-situ 316 stainless steel probe designed for the harshest stack conditions to measure directly in the flue stream. The design of the probe enables accurate measurements to be made even in very high dust level processes exceeding several gram/m 3. Designed for use primarily on combustion processes, the GCEM40 series measures key pollutants such as CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 and H 2 O using an infra-red spectroscopy to ensure that there is no cross sensitivity from other contaminants in the gas stream. The GCEM40 series analysers can be configured in either single or multi-gas mode to give operators a full range of options. Fully automated zero and span calibrations are performed using clean dry compressed air and protocol gas mixtures to provide long-term accuracy along with minimal maintenance requirements. Pneumatics mounted directly on the measurement probe allow both zero and span gas to be injected into the measurement chamber either manually, automatically or remotely. Data Display Unit (DDU) Air Dryer Unit (optional) Stainless Steel 316l All models are fitted with a probe mounted temperature sensor. As an additional option pressure, CO 2 and H 2 O can be measured to provide fully normalised data in mg/nm 3. The GCEM40 Series analyser is available with either a single species measurement for process control or with multi-species measurements for a choice of emissions monitoring. GCEM 40 Series pneumatics

GCEM 40 Series Gas Analyser - System Arrangement DDU Span Gas Input Zero Gas Input Inputs Outputs Power 24V DC @ 15A GCEM 40 Series Gas Analyser - Options 24V DC Power Supply Mains in 110 / 220 VAC For clean/dry oil-free air to -20 C Larger DDU for 5 x current outputs

Overall Dimensions - 2.2m (wt. 74kg) (wt. 23kg) Note: All dimensions are in mm Overall Dimensions - 1.8m (wt. 65kg) (wt. 23kg) Note: All dimensions are in mm Overall Dimensions - 1.0m (wt. 50kg) (wt. 23kg) Note: All dimensions are in mm 340mm Overall Dimensions - Site Flange and Data Display Unit Flange (wt. 10kg) 30mm Min 160mm Stub Pipe supplied by customer 160mm 220mm BS4504 PN16 DN200 Mild steel site flange Flange supplied by 160mm Assembled box 110mm deep Data Display Unit (wt. 3kg)

SmartCEM Software Detailed and customisable reports to meet Regulatory Agency requirements (including LCPD, WID) User configurable real-time and historical graphing facilities for data analysis Data export to popular applications such as Excel etc Multi-user networking capability Real-time normalisation of data Data storage on PC hard drive of at least 10 years Easy installation and set-up Intuitive operation Will operate on Windows based operating systems SmartCEM Emissions Monitoring Software provides the complete solution to data gathering and analysis on -based monitoring systems. With a simple installation and set-up routine, the program takes only minutes to load and configure and comes with a comprehensive on-board help feature. Real-time Displays Using a serial link to communicate with the sensors, SmartCEM updates the live data screen every 30 seconds to keep the user aware of the current situation on plant, while alarms warn the operator of high emission levels. Data is displayed in numerous formats - ppm, %, mg/nm 3, mg/m 3, kg/hr assuming flow measurement is available etc. - and the change of format is instantaneous. Graphs A key feature of SmartCEM is the provision of real-time and historical graphs providing detailed analysis of emissions data. One useful feature enables the user to highlight a period of time on the graph and obtain the average emissions. Data is easy to read and is configurable to individual operator requirements. GSM Unit The GSM unit allows engineers direct access to any analyser in our range giving them full online remote diagnostic information for technical support.* This service can be offered for a nominal monthly charge * Network coverage can limit the use of this service

GCEM 40 Series Gas Analyser - Technical Specification Gas Species Options Single or multi-gas measurements available: Maximum 3 gases from: CO, NO, NO 2, NO x, SO 2, HCl, CH 4 plus gas temperature Plus optional : CO 2, H 2 O, pressure for data normalisation Measuring units ppm, mg/nm³, mg/m³, % Response Time Less than 200 Seconds (T90) Gas Temperature Standard probe - dewpoint to 300 C High-temp probe - dewpoint to 400 C (Other temperatures available on request) Calibration Automatic and manual zero/span verification Gas Species CO, NO, NO 2, NO x, SO 2, CH 4, HCl CO 2, H 2 O Max Measuring Range 0-6000 ppm 0-25% Accuracy +/- 10ppm or 2% of span 0.5% or 2% of span Resolution +/- 1ppm 0.1% Zero & span drift +/- 10ppm or 2% of span 0.5% or 2% of span Linearity +/- 2% of span 2% of span Repeatability +/- 5ppm or 1% of span 0.3% or 1% of span Ambient Temperature -20 C to +50 C or 0 C to +70 C Power supply 24V DC @ 15A Construction Corrosion resistant epoxy coated aluminium housing sealed to IP66 Length 1.0m, 1.8m & 2.2m Construction 316L stainless steel Compliances EMC Low Voltage Data Display Unit Analogue outputs Logic Outputs Inputs Serial Data Display Keypad Construction Ambient Temperature Power Supply Services Power 24V DC @ 15A 89/336/EEC directive compliant 73/23/EEC directive compliant 2 x 4-20mA current outputs as standard, isolated, 500Ω load max, fully configurable from keypad (additional outputs available, see optional items below) 2 x volt-free SPCO contacts, 50V, 1A max, configurable as alarm contacts 1 x volt-free SPCO contact, 50V, 1A max, for data valid signal 1 x 4-20mA for oxygen input (0 2 can also be input at sensor unit) 1 x volt free logic input for plant status or remote calibration initiation RS232/RS485 (MODBUS protocol) 32 Character alpha-numeric back-lit LCD 4-key soft-touch entry epoxy-coated aluminium to IP67-20 C to +50 C 24V DC supplied from sensor unit Continuous Air Clean and dry compressed air @ 4bar to -20 C Optional Items Consumption during normal operation 5 litre/min, during calibration 30 litre/min. Power Supply 110/220VAC, 50Hz +/- 10%, 400VA to 24V DC @ 15A Air Dryer For clean and dry oil free air Additional Outputs 5 x 4-20mA current outputs isolated, 500Ω load max, fully configurable from keypad International Ltd Station Building Station Road Bakewell Derbyshire DE451GE United Kingdom Tel : +44 (0)1629 814351 Fax : +44 (0)8700 566307 Web : Email : sales@codel.co.uk Distributor