CR87B TEMPERATURE RECORDER

Similar documents
INTRODUCTION CT87E FEATURES AND CONTROLS

User s Guide CT89 SERIES. Temperature Recorder. Shop online at. omega.com For latest product manuals: omegamanual.

Shooter Make Ready. SIRT OneShot Installation INNOVATIVE DRY FIRE

COBEX RECORDERS, INC.

T9550LCK

User's Guide. Model Laser Photo Tachometer

T9550 LCM Paging System Transmitter T9550LCM MSG MSG MSG MSG CLR PROG

EM10 TEMPERATURE / HUMIDITY /DEW POINT METER

OM-DLTT DATA LOGGER INSTRUCTIONS

User's Guide. MiniTec TM Series Model MN25 MultiMeter

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

User's Guide. Extech AM A AC Analog Clamp Meter

BG-N19-2. Designed for the Nikon D850 DSLR Camera

User's Guide. Video Borescope. Model BR100

Automated Tuner System Power Distribution Hub

BG-S6. Designed for the Sony a9 and a7 III Series Mirrorless Cameras

INSIDE-OUTSIDE THERMOMETER WITH MIN/MAX MEMORY USER S MANUAL

Electrostatic Fieldmeter Model 775

Mini Digital Multimeter

AirPro Surveyor 2 Manual

Hardware Documentation

User's Manual. Model Heavy Duty Datalogging Module with Windows Software

2005: 0.5 PQ-MDS-PCIEXP

Instruction Sheet Rev. 2

BG-N11 BATTERY GRIP. Designed for the Nikon D7100 SLR Camera

TD 600 Thermo-Fastprinter

NOVPEK NetLeap User Guide

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

Press the PEN HOME key to move the pen(s) to the outside of the chart. The pen(s) is automatically raised off the chart.

OPERATING USER MANUAL for PRESSURE RECORDERS

BG-N4.2 BATTERY GRIP. Designed For The Nikon D7000 SLR Camera

BG-N10. Designed for the Nikon D600 and D610 SLR Camera

Usage, Installation, Warranty and Service Information

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Patented

MODEL ATV 4/6 BATTERY POWERED DIGITAL VACUUM INSTRUMENT

FH125/FT121. Temperature / Humidity LCD Graphing Logger FH125 SET CURSOR. 1 Hour/Div 1 1 : 12 : 23 01/03/02 (ESC)

Digital Contact Tachometer

8-Bit Temperature Smart Sensor (Part # S-TMA-M0XX)

DICKSON FH320/325 & FT300/325 DICKSON. Temperature/Humidity Recorder. Specifications. Applications & Product. Product. Contents: Getting Started

24/7 Sprinkler Monitor. The Ultimate Rain/Freeze Sensor

BG-N8 BATTERY GRIP. Designed For The Nikon D300 and D300s SLR Cameras

Model SRV945-BT 24 X 36 Platform Scale App-Enabled Operating and Service Manual Part No.: MAN945-BT_ Page 1 of 16.

User's Manual Sound Level Alert Model SL130

DIGITAL COMPASS-RD DIGITAL COMPASS REFERENCE DESIGN KIT USER' S GUIDE. 1. Kit Contents. 2. Introduction. 3. Quick-Start Guide. 4. General Description

Sidewinder Pumps Inc. AC Timer/Controller

User's Guide. Phase Sequence and Motor Rotation Tester Model

PixController, Inc. Wireless Magnetic Switch Sensor For Doors, Windows, and Gates

Evaluation-Kit EK-F3(_L;_R;_V)

QuickTouch (QT4) Owner s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

TABLE OF CONTENTS. 9.0 Warranty

Programming and Evaluation Tool for Serial EEPROMs

SATA II HDD Canister KISS DA 435 Quick Reference Guide

User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

Updating the Firmware on USB SPI Boards (KITUSBSPIEVME, KITUSBSPIDGLEVME)

User s Guide. 600A AC Clamp Meter. Model 38387

Freescale Semiconductor, I

SML40-CH04 Chassis CWDM Passive 4 Slot Rack

INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE

What s in the box. SUP paddle sensor. Paddle sensor mounting track. Charger. USB cable. In your Motionize SUP kit you will find:

850A/B Contact Chatter Detector User Manual

Led Illuminator and Light Stimulator. Model # LSD-1. Ver

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

UÊ, Ê* - 1 Ê Ê Ê " /",Ê

Media Control Station 2 MIDI Version User's Manual Third Edition

DCS200/DCS200-09/DCS DCS300/DCS300-09/DCS355

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

ipad Charge & Sync Cart Model MCC2 ipad Cart 430-MCC2-User Manual-010 Is a Registered Trademark of Apple Inc. ipad

PixController, Inc. Wireless Switch Sensor For Normally Open (NO) and Normally Closed (NC) Sensors

Full Product Manual FL-1000

Innovative Circuit Technology Ltd.

Laser Photo/ Contact Tachometer. m/min. ft/min

DICKSON TH801/802/803 DICKSON. Temperature Chart Recorder Operation. Useful Features. Applications & Product. Specifications. Product.

Lotus DX. sit-stand workstation. assembly and operation instructions. MODEL # s: LOTUS-DX-BLK LOTUS-DX-WHT

Model 8702 DP-CALC Micromanometer

XC4100 INSTALLATION/OWNER'S MANUAL AM/FM/Cassette Receiver

Communication Hub. Model: HUB-1. 8 Pheasant Run Newtown, PA USA

ET100/NRZ. Ethernet WAN Bridge. 10/100Base-TX Ethernet over NRZ

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Turbo Fiberglass Cone Fan and Grill Fan 36 Direct Drive. Installation & Operator s Instruction Manual

What s in the Box? Weatherproof Camera transmitter with Antenna Power Cable 3m Sticker. 2 RVS SyStemS

Folding Rackmount Console

STATIC METERS Models 211 & 212. SURVEYORSTAT Models 211XL & 212XL

Sensoray Model 627 CompactPCI to PCI Adapter

1 LIMITED WARRANTY STORCASE TECHNOLOGY, Incorporated ( StorCase ) warrants that its products will be free from defects in material and workmanship, su

PLATINUM PRO6000 PROFESSIONAL SERIES DIGITAL COUNTERTOP / PORTABLE BALANCE

USB DIGITAL SOUND LEVEL DATA LOGGER USER S MANUAL DSM20

Upgrade the Solution With No Changes 2 Upgrade the Solution With No Changes If a Codebase does not contain updates to its properties, it is possible t

Power TracKer VII. User s Manual 2006 AVID. Multi Mode Reader. Manufactured under one or more of the following Patents:

RLD-7.2 Two Channel Light Dimmer. (P/N: P-RLD-72 Digital) User & Installation Manual

700 Series 200 Amp Clamp Meters

Power Cycling Algorithm using the MMA73x0L 3-Axis Linear Accelerometer

Video Borescope Inspection Camera

CM1219. Low Capacitance Transient Voltage Suppressors / ESD Protectors

USER MANUAL. DV-HAS HDMI Audio Separator LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web:

MPE5 Scouting Camera Instruction Manual.

Device Errata MPC860ADS Application Development System Board Versions ENG, PILOT, REV A

FNet Repeater Installation & Operator s Instruction Manual

Innovative Circuit Technology Ltd.

NCP370GEVB. NCP370 Over Voltage Protection Controller with Reverse Charge Control Evaluation Board User's Manual EVAL BOARD USER S MANUAL

Transcription:

CR87B TEMPERATURE RECORDER Sealed Unit Parts Co., inc. PO Box 21, 2230 Landmark Place, Allenwood, NJ 08720 USA Phone: 732-223-6644 Fax: 732-223-1617 www.supco.com info@supco.com 19204

INTRODUCTION The CR87B is a precision instrument used to monitor and record temperature on a 6 circular paper chart. The CR87B may be carried as a portable instrument or mounted in a fixed location. The CR87B offers a variety of features to meet any temperature recording requirements. A combination of three temperature ranges and four chart speeds provide a high degree of flexibility. In addition, the chart rotation may be set for single or continuous turn operation as required by a particular application. To protect the data being recorded the CR87B uses an automatic battery backup to maintain operation during a power outage. 12 TWO REAR KEYWAY SLOTS FOR WALL MOUNTING 13 CHANGING PENS 19 17 LATCH 16 PLUG-IN AC ADAPTER BATTERY HOLDER FIG. 1 1

2 3 12 4 5a 1 7 13 5 18 6 11 8 9 19 10 15 14 16 CR87B 105 TEMPERATURE RECORDER RANGE -40 /30-20 /50 50 /120 SPEED 31 DAY 7 DAY 24 HOUR 6 HOUR PEN ADJ. TEMP. CON SING OFF CHART ADJ. 2

CR87B FEATURES AND CONTROLS 1. The 3 DIGIT TEMPERATURE DISPLAY shows temperature of the environment being monitored. When the batteries are nearly discharged, the display will alternate the display reading and LO to advise the operator that the batteries are discharged and the CR87B will shortly cease operation. NOTE: The battery backup feature of the CR87B is primarily intended for use in situations where primary power is lost for short periods of up to 48 hours. The CR87B is not intended to be used as a battery powered instrument. If the CR87B is to be stored for an extended period, it is strongly advised to disconnect the battery pack and remove the batteries to avoid damage to the instrument from battery leakage. 2. The TEMPERATURE RANGE SELECTOR allows the user to choose the desired temperature range for measurement and recording. 3. The CHART SPEED SELECTOR allows the user to select the time of one full chart revolution. The corresponding chart has to be chosen according to the desired chart speed. Chart part numbers are listed in this manual. 4. The PEN POSITION ADJUSTMENT KNOB allows the user to adjust the position of the chart pen. 5. The CHART ADVANCE BUTTON allows the operator to set the chart to the correct time. Press and hold the chart advance button until the desired time lines up with the Time Pointer. The chart is rotated counterclockwise only. CAUTION: Movement of the Chart Spindle (Item 9) by hand may cause permanent damage to the chart mechanism. 5a.The TIME POINTER 6. TEMPERATURE ADJUSTMENT feature allows the user to adjust the reading of the digital display during periodic calibration. The CR87B has been factory calibrated and requires no adjustment to meet all published specifications. 7. The POWER ON/OFF / CONTINUOUS / SINGLE CHART SELECTOR allows the user to apply power to the CR87B and to select Continuous or Single Turn for the chart rotation. When power is first applied to the CR87B, the display will show 888 to test each segment of the display, and the pen will move to the edge of the chart. The pen will then move to the correct position on the chart. In the Continuous switch position, the chart will rotate until power is removed. In the Single Turn switch position, the chart will make one complete revolution and stop. A blinking dot on the display (Item 1) will indicate that the chart has made one complete revolution and stopped. To reset the chart for another revolution place the switch in the Continuous switch position until the blinking dot goes out and then slide the switch back to the Single Turn position. The chart will make one complete revolution and stop. DO NOT move the pen by hand or interrupt the pen movement. Failure to observe this will cause the pen to read incorrectly and may result in damage to the pen mechanism. 8. The RECORDING PEN contains special ink. The pen has a wrap-around arm latch which makes the pen replacement A SNAP! To replace the pen, gently lift up the PEN ARM, (do not over bend pen arm) release the pen latch by pushing it 3

down, and remove the pen; place a new pen on top of the pen arm, align the notches on the pen arm with the notches on the pen latch and close the latch by wrapping it around the pen holder until it is secured. Replace cap on the pen tip when the CR87B is not used to insure long pen life. For pen installation see Fig. 1. 9. The CHART SPINDLE holds and rotates the chart during the recording operation. DO NOT ROTATE THE SPINDLE BY HAND AS IT MAY DAMAGE THE INTERNAL MECHANISM. 10.The PAPER CHART is 6 inches in diameter. The replacement charts are available from any of Sealed Unit Parts Co., Inc. authorized distributors in a box of 60 charts each. The chart part numbers are listed on the following page. TO INSTALL A NEW CHART disconnect power from the CR87B by selecting OFF with the Power / Single/ Continuous Chart Selector. Place pen cap on pen point. Gently lift the pen arm and while holding it remove the old chart. Slide a new chart under the pen holder and the chart holding tabs. Align the chart with the chart spindle. Apply power to the CR87B and rotate the chart by depressing the chart advance button until the time pointer is aligned with the line on the chart representing the right time or day. Remove the pen cap. If desired, adjust the pen position according to the scale you wish to record. 11.The ROTATION POINTER indicates direction of chart rotation. 12.The HANDLE for carrying folds towards the back of the case to be out of the way when CR87B is mounted on the panel or on the wall. 13.The KEYHOLE SLOTS located on the back of the case are provided for wall or panel mounting. 14.The FRONT COMPARTMENT under chart was designed to store the battery holder for battery backup as well as the connection for the adapter box. 15.The REMOTE TEMPERATURE SENSOR is interchangeable. The furnished 4" stainless steel sensor has 15 feet of cable. The temperature sensor is an electronic digital proprietary design for precision and very high interference immunity. It utilizes the standard RCA connector. The sensor cable may be extended with an extension cable available from Sealed Unit Parts Co., Inc. or its distributors. 4

16. The BATTERY HOLDER is stored in the front compartment for backup batteries. Use of 8 alkaline AA batteries is required for proper operation. 17.The 12VDC PLUG IN WALL ADAPTER provides primary power for the CR87B. Alternate sources of 12 Volt power may also be used. This allows use of the CR87B in automotive, marine or other mobile applications. 18.The POWER CONNECTOR is a connection point for the 12VDC wall adapter or alternate source of 12VDC power. 19.Back Brace for counter top use. CHARTS Temperature Chart Speeds Ranges 6 Hours 24 Hours 7 Days 31 Days -40 F to +30 F CR87-4 CR87-1 CR87-7 CR87-19 -20 F to +50 F CR87-5 CR87-2 CR87-8 CR87-20 +50 F to +120 F CR87-6 CR87-3 CR87-9 CR87-21 -40 C to 0 C CR87-13 CR87-10 CR87-16 CR87-22 -30 C to +10 C CR87-14 CR87-11 CR87-17 CR87-23 +10 C to +50 C CR87-15 CR87-12 CR87-18 CR87-24 SPECIFICATIONS Temperature Scale Selectable -40 F to +30 F, -20 F to +50 F, (Fahrenheit Model) +50 F to +120 F Temperature Scale Selectable -40 C to 0 C, -30 C to +10 C, (Celsius Model) +10 C to +50 C Chart Speed Selectable 6 Hours, 24 Hours, 7 Days, 31 Day Chart Speed Accuracy +/-1% Chart Diameter 6 Inches Temperature Display 3 Digit LED 0.5" Temperature Accuracy +/-2 F (+/-1 C) Temperature Sensor Stainless steel tip submersible with 15 ft. of cable Recording Pen Ink Type Power Supply 120 VAC, 50/60 Hz. or 220/240 VAC, 50Hz. Battery Backup 8 Alkaline AA cells (Not included) Battery Life 48 Hours Operating Ambient Temperature Range +32 F to +120 F (0 C to +49 C) Relative Humidity 96% maximum Dimensions 9 ¼ x 7 ¼ x 2 ¾ Weight 4 lbs., 7 oz. CAUTION: The Temperature Recorder should be placed outside the chamber being monitored. DO NOT PLACE THE RECORDER DIRECTLY IN AREAS OF EXTREME TEMPERATURES, HIGH HUMIDITY OR HEAVY CHEMICAL CONTENT. 5

Limited Warranty Sealed Unit Parts Co., Inc. hereby warrants that it will repair or replace, at its option, any part of the CR87B Temperature Recorder, which proves defective by reason of improper workmanship or material, free of charge for parts and labor, for a period of one year from the date of original purchase by the buyer. This warranty does not apply if, in the sole opinion of Sealed Unit Parts Co., Inc., the CR87B Temperature Recorder has been intentionally damaged due to misuse, neglect, improper packing, shipping, modification of servicing by other than Sealed Unit Parts Co., Inc., or personnel authorized by Sealed Unit Parts Co., Inc.. For information on how to obtain service under this warranty contact the dealer where your CR87B Temperature Recorder was purchased, or Sealed Unit Parts Co., Inc. at the address printed below: SEALED UNIT PARTS CO., INC. 2230 Landmark Place, Allenwood, NJ 08720 USA Phone: (732) 223-6644 Fax: (732) 223-1617 www.supco.com info@supco.com Liability Disclaimer Statement Sealed Unit Parts Co., Inc. (hereafter known as Supco) makes no warranty, representation, or guarantee regarding the suitability of its products for any particular purpose, nor does Supco assume any liability arising out of the application or use of any product, and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Supco products are not designed, intended, or authorized for use as components in life support systems, or for any other application in which the failure of the Supco product could create a situation where personal injury or death or significant financial loss may occur. Should any person or persons purchase or use Supco products for any such unintended or unauthorized application, that person or persons shall indemnify and hold Supco, and its officers, employees, affiliates, and distributors harmless against all claims, costs, damages, expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury, death or financial loss associated with such unintended or unauthorized use, even if such claim alleges that Supco was negligent regarding the design or manufacture of the product in question. 6

SEALED UNIT PARTS CO., INC. 2230 Landmark Place, Allenwood, NJ 08720 USA Phone: (732) 223-6644 Fax: (732) 223-1617 www.supco.com info@supco.com 20589 REV-011708