SCC Inc. LMV5 Series. Installation Instructions. Document No. LV February 12, 2018

Similar documents
Inc. SCC. for use OCI This allows or building managemen. SCC Inc.

SCC Inc. LME Series. Installatin Instructins Document No. LME 6100 December 10, OCI fir use with LME7 Flame Safeguards.

SCC Inc. TS Series TS Touchscreen Kits. Installation Instructions. Document No. TS 1100 February 14, Description

SCC Inc. TS Series TS Touchscreen Kits. Installation Instructions. Document No. TS 1100 March 16, Description

SCC Inc. TS Series. Installation Instructions. Document No. TS-1100 July 18, TS Touchscreen Kits for use with LMV3, LMV5 and RWF Controls

SCC Inc. TS Series TS MS Master Panels for Boiler Management, Lead/Lag, and Building Management System Interface. Installation Instructions

Master Panel. Specifications. Document No. TS-2010 February 15, Product Description. Sample Specification

SCC Inc. TS Series. Technical Instructions. Document No. TS-2000 March 15, 2016

MODBUS AND BACNET COMMUNICATION INSTRUCTIONS

SCC Inc. TS Series. Technical Instructions. Document No. TS-4000 March 10, TS-CE Combustion Enclosures with LMV5.

MODBUS AND BACNET COMMUNICATION INSTRUCTIONS

LMV2 / LMV3... Modbus. User Documentation. Building Technologies Division

SCC Inc. TS Series Application Guide. Technical Instructions. Document No. TS 8000 January 9, Description

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

Flamma BIOMASS COMBUSTION SYSTEM CONTROLLER. Preliminary Description V.1 Santi Moroño / Jose Caldelas / Juan R. Regueiro / 26/02/ :34

SCC Inc. TS Series. Technical Instructions Document No. TS-1050 March 10, TS Serial Communication Kits for use with LMV3, LMV5, and RWF Controls

LMV51... / LMV52. Trouble / Modbus

MODBUS COMMUNICATION INSTRUCTIONS

MODBUS AND BACNET COMMUNICATION INSTRUCTIONS

USER MANUAL. Modbus IHP24-A IHP24-AF IHP24-B IHP24-BF IHP24-F IHP24-I 1/26

SCC Inc. TS-D Series. Technical Instructions. Document No. TS-3000 March 10, Deaerator, Surge and/or Condensate Control Panel.

EasyIO FC20 User Reference v1.3. EasyIO FC 20 DDC User Reference V1.3

FCU-4 FAN COIL CONTROLLER

Belimo Gateway MP to Modbus RTU - UK24MOD

FCU-4 FAN COIL CONTROLLER

Q9 ASD LOW VOLTAGE DRIVE

BMS Steam Station Solutions

PROFIRE PF3100 Modbus Register Map PF

CONTROLS.COM. Bacnet and Modbus Modules. T3-22i. T3000 Building Automation System Overview. T3-8o. Ethernet MAIN NET1 RS485 SUBNET2 RS485.

isma-b-fcu FCU Hardware User Manual Global Control 5 Sp. z o.o. Warsaw, Poland

LC-1 Level Controller & Flow Monitor

Heatronic Introduction. BAS Integration Manual. Table of Contents

W8735A1013 EnviraCOM Serial Adapter

Belimo Gateway MP to Modbus RTU - UK24MOD

NF770 Temperature Compensation Liquid Flow Computer

System-10 BTU Meter BACnet Network Interface Installation Guide

Webinar Organizers. Ryan Shea. Bruce McDuffee. Joe Ryan. Webinar Moderator. Applications Specialist. Product Manager. Precision Digital Corporation

MODBUS COMMUNICATION INSTRUCTIONS

BACnet Flow Controller for Fan Filter Units

Deaerator and Surge Tank Control

NEXUS NX6100/PPC6000 SERIES MODBUS COMMUNICATIONS

PROGRAMMING INSTRUCTIONS

InVerde. Modbus Networking. M.1 Description NOTE. M.2 External Communications Network. Implementation. By TECOGEN

QUICK START GUIDE M2000 SERIES rue Charles, Suite 100, Mirabel, QC, J7J 1X9

EC700. Pulses concentrator. User instructions

For more information Contact with details of the application.

System-10 BTU Meter BACnet Network Interface Installation Guide

LC-5 Level Controller & Flow Monitor

LC-3 Flow Monitor & Pump Run Verification

Ocean Controls KTA-224 Modbus IO Module

DIN-TSTAT-FCU DIN-Rail Heating and Cooling Fan-Coil Thermostat

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE

RS 485 Mini Modbus 1AO

FRICK QUANTUM HD UNITY SYSTEM CONTROLLER

mbc082 Bus Converter

NF760 Batch Controller

MODBUS COMMUNICATION INSTRUCTIONS

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

D-100 FLOW DISPLAY BACnet Network Interface Installation Guide

BACnet Protocol Implementation Conformance Statement

PF MODBUS REGISTER MAP. v1.4 Revised Nov 29, 2016

Small distributed I/O module

Submittal Data Sheet intelligent Touch Manager DCM601A71

C Heat Trace Controller

Modbus Integration Integration for Modbus Functionality for VTR8300 Series

IntesisBox Modbus Server M-Bus

INSTRUCTION MANUAL V1. 2x A

Clear Benefits of the KRAL Electronic.

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

System Overview CMS Combustion Management System

KRAL Electronics BEM 300 and BEM 500.

Modbus communication module for TCX2: AEX-MOD

Quick Start Guide DDC (2014/02) Subject to change without prior notice Quick Start Guide

Carbon Monoxide Sensor - ModBus

SDC-20G/32G Graphics Series Distributed Controller Reference Manual

How to control and monitor up to 16 Motor Insight motor protection relays via an HMi and Modbus serial

GE Power Management. MMII Intelligent MCC Controller

PC-3000x PC-3000xC PUMP CONTROLLER. User Manual 844-4PRIMEX ( ) WATER SYSTEM INTEGRATOR AND CONTROLS PROVIDER

ETHERNET/MFC 010 Technical Datasheet

PowerView. Model PV-101-A, V2.3 User s Guide Section 78

System Overview Fuel/air ratio control system VMS. Sensors and systems for combustion engineering.

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Micro Motion Model 7950 and Model 7951 Signal Converters

MODBUS COMMUNICATION INSTRUCTIONS

Modbus Manual. ACL3200 Controller

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Smart Equipment Controls (SEC)

User Guide. For controller on CXAO / RTXB heat pumps CGCM / CXCM 2 circuit units. CNT-SVU005C-GB Original instructions

RS485 MODBUS Module 6RO

T3 Series Bacnet Programmable Controller

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

RS485 MODBUS Module 8AO

Model 2000 Programmer EnSonic Display & Control Unit. Document code: M2KCNF.001

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

M2500 Engine Controller Configuration Manual

Operation. Symmetra MW II. Parallel System with Internal Bypass Static Switch. Normal Normal. UPS Summary. X405 UPS Summary.

LoRaWAN Wzzard Utility Quick Guide. v /11/1

PowerView. Model PV-101 User s Guide. Rev Catalog Section 78

RS485 MODBUS Module 8I8O

FRICK QUANTUM ACUair CONTROL PANEL Version 2.1x

Transcription:

Installation Instructions February 12, 2018 OCI415.30 for use with LMV5... Linkageless Burner Management Systems OCI415.30 Description The OCI415.30 provides the LMV5... family of flame controllers with a Modbus RTU or BACnet MS/TP interface. This allows the interconnection of one or more LMV5... to a PLC or building management system (BMS).

Installation Instructions Table of Contents Compatible Controls... 3 Linkageless Burner Management Systems... 3 Physical Connections... 4 Power... 4 Connection to LMV5... 4 Connection to BMS... 5 Status LED... 5 Tx/Rx LED... 5 Required LMV5 Configuration... 6 Modbus RTU Connection Details... 7 BACnet MS/TP Connection Details... 8 Configuration Utility... 9 Using the Configuration Utility... 9 Updating Firmware... 11 Modbus RTU Mapping... 12 BACnet MS/TP Mapping... 13 Page 2

Installation Instructions Compatible Controls Linkageless Burner Management Systems LMV51... LMV52... Page 3

Installation Instructions Physical Connections Power Power to the OCI415.30 must be either 9 24VDC or 9 24VAC (nominal). Power consumption is 2.5W or less. SCC part number AGA15 24 is available as a suitable power supply. Terminal designations: Connection to LMV5... Label Function L+ DC + / AC ~ N DC / AC ~ The connection from the OCI415.30 to the LMV5 should be made with the supplied cable. The connection at the LMV5 is to the AZL X72 (COM2) port. Maximum allowed cable length is 5 meters. Page 4

Installation Instructions Physical Connections (continued) Connection to BMS The connection from the BMS to the OCI415.30 is via terminal block. The physical medium is RS 485. Multiple RS 485 nodes may be connected in a daisy chain. For long runs (typically greater than 1000 feet) or noisy environments, termination may be required on the end node. Terminal designations: Status LED Label Function A RS 485 Data (+) B RS 485 Data ( ) G RS 485 Common Ground The status LED annunciates the status of the OCI415.30 and the connection to the LMV5 Tx/Rx LED Color Green Flashing Green / Red Alternating Red Flashing Status No Connection to LMV5 Communicating with LMV5 Internal Error OCI415.30 The LED will flash red to indicate incoming communication on the RS 485 connection. The LED will flash green to indicate outgoing communication. With normal communication, the LED will rapidly alternate between green and red. NOTE: If the poll rate is fast the flashes may be very brief and hard to notice. Page 5

Installation Instructions Required LMV5 Configuration Use the Select < and Select > buttons to navigate up and down the screen and the Enter button when the desired option is selected with the cursor. Use Esc to go back to the previous menu. When a parameter needs to be changed, the Select < and Select > buttons allow the value to be changed and Enter confirms the change. Press the Esc button to return after the change is made. First, activate the Modbus port on the AZL (no password required): 1. Operation > OptgModeSelect > Type of Gateway = Modbus 2. Operation > OptgModeSelect > GatewayBASon Note: Older AZL units may read 'GatewayDDCon' instead. 3. The AZL should now read 'Gateway Mode active'. Next, set up the required parameters through the AZL (no password required): 1. Params & Display > Access w out PW > AZL > Modbus > Address = 1 2. Params & Display > Access w out PW > AZL > Modbus > Baudrate = 19200 bit/s 3. Params & Display > Access w out PW > AZL > Modbus > Parity = no 4. Params & Display > Access w out PW > AZL > Modbus > Timeout = 30s If remote operation is desired the load controller operating mode must be changed to IntLC Bus using the following procedure (no password required): 1. Params & Display > Access w out PW > LoadController > Configuration > LC_OptgMode = IntLC Bus The changes take effect immediately (no reboot required). Page 6

Installation Instructions Modbus RTU Connection Details Modbus RTU protocol selection and addressing is done using the PC tool OCI Configuration Utility (see next section). Supported addresses: 1 247 Supported baud rates: 2400, 4800, 9600, 19200, 38400, 57600, and 115200 Supported data bits: 8 Supported parity and stop bits: none (1 or 2 stop bits), odd (1 stop bit), and even (1 stop bit) Supported function codes: 3 (read holding registers), 4 (read input registers), 6 (write single holding register), and 16 (write multiple holding registers) Maximum read length: 125 (if beginning and ending registers are valid addresses) Page 7

Installation Instructions BACnet MS/TP Connection Details BACnet MS/TP protocol selection and addressing is done using the PC tool OCI Configuration Utility (see next section). Supported addresses: 0 127 Supported baud rates: 9600, 19200, 38400, 57600, 76800, and 115200 Supported data bits: 8 Supported parity and stop bits: none (1 stop bit) Supported device instances: 0 4194302 Page 8

Installation Instructions Configuration Utility Using the Configuration Utility 1. Double click the icon to open the configuration utility. 2. The utility will open and show the connection status of the OCI415.30. Page 9

Installation Instructions Configuration Utility (continued) 3. Use a mini USB cable to connect the OCI415.30 to the computer, such as SCC part number AGA5 05M. A driver may self install the first time a connection is made. The connected device will then be indicated on the screen. 4. The protocol can be changed between Modbus RTU and BACnet MS/TP from this screen. See the previous sections for further details on the protocol specific settings that can be changed. Once the desired settings have been entered, click Submit to apply. Click Reload to refresh the displayed settings. Page 10

Installation Instructions Configuration Utility (continued) Updating Firmware 1. From the OCI415.30 Configuration Utility, click File > Update Device 2. Locate the supplied update file with a.duf extension and click Open. 3. The device will automatically reboot and reconnect with the OCI415.30 Configuration Utility once the firmware update is complete. When a device is connected, the firmware version is shown as one of the read only parameters. Page 11

Installation Instructions Modbus RTU Mapping (continued) Refer to Document No. LV5 1000 (LMV5 Technical Instructions) for complete Modbus mapping information. Page 12

Installation Instructions BACnet MS/TP Mapping Point Name Type Instance Units Active Text Inactive Text PHASE ANALOG INPUT 1 NO UNITS FUEL ACTUATOR ANALOG INPUT 2 ANG DEG GAS ACTUATOR ANALOG INPUT 3 ANG DEG OIL ACTUATOR ANALOG INPUT 4 ANG DEG AIR ACTUATOR ANALOG INPUT 5 ANG DEG AUX1 ACTUATOR ANALOG INPUT 6 ANG DEG AUX2 ACTUATOR ANALOG INPUT 7 ANG DEG AUX3 ACTUATOR ANALOG INPUT 8 ANG DEG VSD ANALOG INPUT 9 PERCENT CURRENT OUTPUT ANALOG INPUT 10 PERCENT CURRENT SETPOINT ANALOG INPUT 11 NO UNITS ACTUAL VALUE ANALOG INPUT 12 PERCENT FLAME SIGNAL ANALOG INPUT 13 PERCENT FUEL FLOW ANALOG INPUT 14 NO UNITS CURRENT O2 VALUE ANALOG INPUT 15 PERCENT SENSOR TYPE (SEE NOTE 1) ANALOG INPUT 16 NO UNITS START COUNTER ANALOG INPUT 17 NO UNITS HOUR COUNTER ANALOG INPUT 18 NO UNITS ERROR CODE ANALOG INPUT 19 NO UNITS DIAGNOSTIC CODE ANALOG INPUT 20 NO UNITS ERROR CLASS ANALOG INPUT 21 NO UNITS ERROR PHASE ANALOG INPUT 22 NO UNITS SUPPLY AIR TEMPERATURE ANALOG INPUT 23 NO UNITS FLUE GAS TEMPERATURE ANALOG INPUT 24 NO UNITS COMBUSTION EFFICIENCY ANALOG INPUT 25 PERCENT PROGRAM STOP (SEE NOTE 2) ANALOG VALUE 26 NO UNITS LC OPER MODE (SEE NOTE 3) ANALOG VALUE 27 NO UNITS AZL OPER MODE (SEE NOTE 4) ANALOG VALUE 28 NO UNITS LOCAL REMOTE (SEE NOTE 5) ANALOG VALUE 29 NO UNITS TIMEOUT ANALOG VALUE 30 SECONDS REMOTE MODE (SEE NOTE 5) ANALOG VALUE 31 NO UNITS REMOTE SP W3 (SEE NOTE 5) ANALOG VALUE 32 NO UNITS REMOTE FIRE RATE (SEE NOTE 4) ANALOG VALUE 33 PERCENT SETPOINT W1 ANALOG INPUT 34 NO UNITS SETPOINT W2 ANALOG INPUT 35 NO UNITS DAY OF WEEK (0=SUNDAY) ANALOG INPUT 36 NO UNITS YEAR 2 DIGIT ANALOG INPUT 37 NO UNITS MONTH ANALOG INPUT 38 NO UNITS DAY ANALOG INPUT 39 NO UNITS HOUR ANALOG INPUT 40 NO UNITS MINUTE ANALOG INPUT 41 NO UNITS SECOND ANALOG INPUT 42 NO UNITS HOURS GAS RESET (SEE NOTE 6) ANALOG VALUE 43 HOURS HRS OIL S1 RESET (SEE NOTE 6) ANALOG VALUE 44 HOURS HRS OIL S2 RESET (SEE NOTE 6) ANALOG VALUE 45 HOURS Page 13

Installation Instructions BACnet MS/TP Mapping (continued) Point Name Type Instance Units Active Text Inactive Text HRS OIL S3 RESET (SEE NOTE 6) ANALOG VALUE 46 HOURS HOURS RUN RESET (SEE NOTE 6) ANALOG VALUE 47 HOURS HOURS RUN TOTAL ANALOG INPUT 48 HOURS HOURS POWERED ANALOG INPUT 49 HOURS STARTS GAS RESET (SEE NOTE 6) ANALOG VALUE 50 NO UNITS STARTS OIL RESET (SEE NOTE 6) ANALOG VALUE 51 NO UNITS STARTS RESET (SEE NOTE 6) ANALOG VALUE 52 NO UNITS STARTS TOTAL ANALOG INPUT 53 NO UNITS FUEL VOLUME F0 (SEE NOTE 6) ANALOG VALUE 54 PERCENT FUEL VOLUME F1 (SEE NOTE 6) ANALOG VALUE 55 NO UNITS NUMBER OF FAULTS ANALOG INPUT 56 NO UNITS EXTRA TEMP SENSOR ANALOG INPUT 57 NO UNITS MINIMUM FIRE RATE GAS ANALOG INPUT 58 PERCENT MAXIMUM FIRE RATE GAS ANALOG INPUT 59 PERCENT MINIMUM FIRE RATE OIL ANALOG INPUT 60 PERCENT MAXIMUM FIRE RATE OIL ANALOG INPUT 61 PERCENT LOAD LIMIT MODULATING ANALOG VALUE 62 PERCENT LOAD LIMIT STAGING ANALOG VALUE 63 PERCENT P VALUE ANALOG VALUE 64 PERCENT I VALUE ANALOG VALUE 65 NO UNITS D VALUE ANALOG VALUE 66 NO UNITS LOCKOUT CODE (SEE NOTE 7) ANALOG INPUT (20 * x) + 100 PERCENT LOCKOUT DIAG (SEE NOTE 7) ANALOG INPUT (20 * x) + 101 NO UNITS LOCKOUT CLASS (SEE NOTE 7) ANALOG INPUT (20 * x) + 102 NO UNITS LOCKOUT PHASE (SEE NOTE 7) ANALOG INPUT (20 * x) + 103 NO UNITS LOCKOUT OUTPUT (SEE NOTE 7) ANALOG INPUT (20 * x) + 104 PERCENT LOCKOUT YEAR (SEE NOTE 7) ANALOG INPUT (20 * x) + 105 NO UNITS LOCKOUT MONTH (SEE NOTE 7) ANALOG INPUT (20 * x) + 106 NO UNITS LOCKOUT DAY (SEE NOTE 7) ANALOG INPUT (20 * x) + 107 NO UNITS LOCKOUT HOUR (SEE NOTE 7) ANALOG INPUT (20 * x) + 108 NO UNITS LOCKOUT MINUTE (SEE NOTE 7) ANALOG INPUT (20 * x) + 109 NO UNITS LOCKOUT SECOND (SEE NOTE 7) ANALOG INPUT (20 * x) + 110 NO UNITS LOCKOUT START (SEE NOTE 7) ANALOG INPUT (20 * x) + 111 NO UNITS LOCKOUT HOUR (SEE NOTE 7) ANALOG INPUT (20 * x) + 112 NO UNITS ERROR CODE (SEE NOTE 7) ANALOG INPUT (10 * x) + 280 NO UNITS ERROR DIAG (SEE NOTE 7) ANALOG INPUT (10 * x) + 281 NO UNITS ERROR CLASS (SEE NOTE 7) ANALOG INPUT (10 * x) + 282 NO UNITS ERROR PHASE (SEE NOTE 7) ANALOG INPUT (10 * x) + 283 NO UNITS ERROR OUTPUT (SEE NOTE 7) ANALOG INPUT (10 * x) + 284 PERCENT ERROR START (SEE NOTE 7) ANALOG INPUT (10 * x) + 285 NO UNITS CURRENT FUEL BINARY INPUT 1 OIL GAS UNIT TYPE BINARY INPUT 2 STANDARD METRIC CONTROL SWITCH BINARY INPUT 3 ON OFF FAN CONTACTOR BINARY INPUT 4 ON OFF OIL SELECTED BINARY INPUT 5 ON OFF GAS SELECTED BINARY INPUT 6 ON OFF Page 14

Installation Instructions BACnet MS/TP Mapping (continued) Point Name Type Instance Units Active Text Inactive Text HIGH OIL SWITCH BINARY INPUT 7 ON OFF LOW OIL SWITCH BINARY INPUT 8 ON OFF VALVE PROVING BINARY INPUT 9 ON OFF SAFETY LOOP BINARY INPUT 10 ON OFF LOW GAS SWITCH BINARY INPUT 11 ON OFF HIGH GAS SWITCH BINARY INPUT 12 ON OFF AIR SWITCH BINARY INPUT 13 ON OFF OIL RELEASE BINARY INPUT 14 ON OFF HEAVY OIL START BINARY INPUT 15 ON OFF ALARM BINARY INPUT 16 ON OFF IGNITION BINARY INPUT 17 ON OFF START SIGNAL BINARY INPUT 18 ON OFF FAN OUTPUT BINARY INPUT 19 ON OFF OIL PUMP BINARY INPUT 20 ON OFF OIL VALVE SV BINARY INPUT 21 ON OFF OIL VALVE V1 BINARY INPUT 22 ON OFF OIL VALVE V2 BINARY INPUT 23 ON OFF OIL VALVE V3 BINARY INPUT 24 ON OFF GAS VALVE SV BINARY INPUT 25 ON OFF GAS VALVE V1 BINARY INPUT 26 ON OFF GAS VALVE V2 BINARY INPUT 27 ON OFF GAS VALVE PV BINARY INPUT 28 ON OFF FUEL SELECT BINARY VALUE 29 OIL GAS LOCKOUT FUEL (SEE NOTE 7) BINARY INPUT 30 + x OIL GAS ERROR FUEL (SEE NOTE 7) BINARY INPUT 39 + x OIL GAS Note 1 Sensor type. 0: Pt100 1: Pt1000 2: Ni1000 3: Temperature (4 20mA, 0 10V) 4: Pressure (4 20mA, 0 10V) 5: Pt100Pt1000 6: Pt100Ni1000 7: No sensor Note 2 LMV program stop. 0: deactivated 1: prepurge phase 24 2: ignition position phase 36 3: interval 1 phase 44 4: interval 2 phase 52 Page 15

Installation Instructions BACnet MS/TP Mapping (continued) Note 3 Load control operating mode. 0: ExtLC X5 03 1: IntLC 2: IntLC Bus 3: IntLC X62 4: ExtLC X62 5: ExtLC Bus Note 4 AZL operating mode. 0: Automatic 1: Burner on 2: Burner off Note 5 Set local/remote (AV29) to 1 for remote. Once in remote the desired mode can be set using AV31 (0 = local/automatic, 1 = burner on, 2 = burner off). If AV31 is set to automatic, write the desired setpoint using AV32. If AV31 is set to burner on, write the desired firing rate using AV33. The firing rate must be between 0% and 100% to remain valid. AV29 must be actively written at least once during the timeout period to reset the timeout counter. Once the timeout counter reaches the timeout value local/remote will revert to local (failsafe operation). Note 6 Counter values can only be reset to zero. Note 7 There are 9 lockouts in memory (current plus 8 history). There are 21 errors in memory (current plus 20 history). The addresses for the historical data are all in the same format as shown in the mapping. Use the formula to find the correct instance. For example, the analog input instance for the ERROR CODE history index 4 would be (10 x 4) + 280 = 320, or AI320. The analog input instance for the LOCKOUT OUTPUT history index 7 would be (20 x 7) + 104 = 244, or AI244. Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Product or company names mentioned herein may be the trademarks of their respective owners. 2017 Page 16