Intel True Scale Fabric Switches Series

Similar documents
True Scale Fabric Switches Series

QLogic Family of QDR InfiniBand Switches. Table of Contents

Intel Omni-Path Fabric Manager GUI Software

HP BLc Intel 4X QDR InfiniBand Switch Release Notes. Firmware Version

Intel Omni-Path Fabric Manager GUI Software

Intel Omni-Path Fabric Switches

Intel Omni-Path Fabric Manager GUI Software

Clear CMOS after Hardware Configuration Changes

HP BLc QLogic 4X QDR InfiniBand Switch Release Notes. Firmware Version

Intel Omni-Path Fabric Switches

Intel Unite Plugin Guide for VDO360 Clearwater

Intel Unite. Intel Unite Firewall Help Guide

QLogic QDR InfiniBand Switch. Table of Contents

Omni-Path Cluster Configurator

Intel Unite Solution Version 4.0

Intel Unite Plugin for Logitech GROUP* and Logitech CONNECT* Devices INSTALLATION AND USER GUIDE

Intel Unite Solution Intel Unite Plugin for WebEx*

IPSO 6LoWPAN IoT Software for Yocto Project* for Intel Atom Processor E3800 Product Family

Intel Unite Solution Version 4.0

Intel Unite Solution Version 4.0

Intel Celeron Processor J1900, N2807 & N2930 for Internet of Things Platforms

Intel & Lustre: LUG Micah Bhakti

Intel Unite Solution Version 4.0

Intel Unite Solution. Plugin Guide for Protected Guest Access

Intel Security Dev API 1.0 Production Release

Intel Firmware Support Package (Intel FSP) for Intel Xeon Processor D Product Family (formerly Broadwell-DE), Gold 001

Modernizing Meetings: Delivering Intel Unite App Authentication with RFID

BIOS Implementation of UCSI

Intel Ethernet Controller I350 Frequently Asked Questions (FAQs)

Intel Compute Card Slot Design Overview

Intel QuickAssist for Windows*

Localized Adaptive Contrast Enhancement (LACE)

MANAGING NODE CONFIGURATION WITH 1000S OF NODES

Intel Xeon W-3175X Processor Thermal Design Power (TDP) and Power Rail DC Specifications

Intel Software Guard Extensions Platform Software for Windows* OS Release Notes

Intel Unite Solution. Plugin Guide for Protected Guest Access

Intel Visual Compute Accelerator Product Family

Intel Cache Acceleration Software - Workstation

Intel Cache Acceleration Software for Windows* Workstation

Intel Unite Solution. Linux* Release Notes Software version 3.2

SilverStorm Table of Contents

Intel Omni-Path Fabric Switches GUI

White Paper. May Document Number: US

IEEE1588 Frequently Asked Questions (FAQs)

Intel Unite Solution Intel Unite Plugin for Ultrasonic Join

Intel Quark Microcontroller Software Interface Pin Multiplexing

Intel Entry Storage System SS4000-E

Intel Cache Acceleration Software (Intel CAS) for Linux* v2.9 (GA)

Intel Solid State Drive Firmware Update Tool

Intel Unite. Enterprise Test Environment Setup Guide

Optimization of Lustre* performance using a mix of fabric cards

Intel QuickAssist for Windows*

Intel Visual Compute Accelerator Product Family

Intel System Information Retrieval Utility

Andreas Dilger High Performance Data Division RUG 2016, Paris

Intel X48 Express Chipset Memory Controller Hub (MCH)

Intel Dynamic Platform and Thermal Framework (Intel DPTF), Client Version 8.X

Intel 82580EB/82580DB GbE Controller Feature Software Support. LAN Access Division (LAD)

Intel Embedded Media and Graphics Driver v1.12 for Intel Atom Processor N2000 and D2000 Series

Configuring Non-Volatile Memory Express* (NVMe*) over Fabrics on Intel Omni-Path Architecture

No license (express or implied, by estoppel or otherwise) to any intellectual property rights is granted by this document.

Intel Atom Processor E3800 Product Family Development Kit Based on Intel Intelligent System Extended (ISX) Form Factor Reference Design

Intel System Event Log Viewer Utility

HAProxy* with Intel QuickAssist Technology

V10.4 Unified Firmware Update. Release Notes & Installation Instructions

Evolving Small Cells. Udayan Mukherjee Senior Principal Engineer and Director (Wireless Infrastructure)

Zhang, Hongchao

Stanislav Bratanov; Roman Belenov; Ludmila Pakhomova 4/27/2015

GUID Partition Table (GPT)

Intel Extreme Memory Profile (Intel XMP) DDR3 Technology

LED Manager for Intel NUC

A3800 & A3600. Service Release SR2.1 Release Notes. A-Class. VTrak A-Class firmware version Clients

QLogic BS21, , and InfiniBand Switches IBM Power at-a-glance guide

Intel Server Board S2600CW2S

Intel Server Compute Blade SBX82

INTEL PERCEPTUAL COMPUTING SDK. How To Use the Privacy Notification Tool

Intel Server Board S2600STB

Intel Manycore Platform Software Stack (Intel MPSS)

CC Software version 1.5.0

Open-E Data Storage Server. Intel Modular Server

Intel Integrated Native Developer Experience 2015 (OS X* host)

The Intel Processor Diagnostic Tool Release Notes

Intel Server Board S1200V3RPO Intel Server System R1208RPOSHORSPP

6th Generation Intel Core Processor Series

Intel Open Network Platform Release 2.0 Hardware and Software Specifications Application Note. SDN/NFV Solutions with Intel Open Network Platform

Intel Galileo Firmware Updater Tool

Intel Omni-Path Fabric Switches GUI

Intel RealSense D400 Series Calibration Tools and API Release Notes

Intel Server Board S1200V3RPO Intel Server System R1208RPOSHORSPP

Hetero Streams Library (hstreams Library) User's Guide

Running Docker* Containers on Intel Xeon Phi Processors

Intel Desktop Board DQ57TM

Intel Setup and Configuration Service Lite

Intel Desktop Board DZ68DB

BIOS Update Release Notes

Intel Speed Select Technology Base Frequency - Enhancing Performance

SELINUX SUPPORT IN HFI1 AND PSM2

Intel SRCS28X RAID Controller 814G Firmware Upgrade for Intel Storage System SSR316MJ+

Intel vpro Technology Virtual Seminar 2010

NVDIMM DSM Interface Example

Transcription:

Intel True Scale Fabric Switches 12000 Series Doc. Number: H70235 Revision: 001US

No license (express or implied, by estoppel or otherwise) to any intellectual property rights is granted by this document. Intel disclaims all express and implied warranties, including without limitation, the implied warranties of merchantability, fitness for a particular purpose, and non-infringement, as well as any warranty arising from course of performance, course of dealing, or usage in trade. This document contains information on products, services and/or processes in development. All information provided here is subject to change without notice. Contact your Intel representative to obtain the latest forecast, schedule, specifications and roadmaps. The products and services described may contain defects or errors which may cause deviations from published specifications. You may not use or facilitate the use of this document in connection with any infringement or other legal analysis concerning Intel products described herein. You agree to grant Intel a non-exclusive, royalty-free license to any patent claim thereafter drafted which includes subject matter disclosed herein. Copies of documents which have an order number and are referenced in this document, or other Intel literature, may be obtained by calling 1-800-548-4725, or by visiting: http://www.intel.com/design/literature.htm Intel and the Intel logo are trademarks of Intel Corporation in the U.S. and/or other countries. *Other names and brands may be claimed as the property of others. Copyright 2015, Intel Corporation. All rights reserved. Intel 2 Doc. Number: H70235 Revision: 001US

Contents 1.0 Overview of the Release...5 1.1 Introduction...5 1.2 Audience...5 1.3 If You Need Help...5 1.4 New Features and Enhancements...5 1.5 Installation Requirements...5 1.6 Changes to Hardware Support...5 1.7 Changes to Industry Standards Compliance...5 1.8 Miscellaneous...6 1.9 Documentation...6 2.0 Bug Fixes...7 2.1 Known Issues...8 Doc. Number: H70235 Revision: 001US 3

Tables 1 Related Documentation for this Release...7 2 Resolved Issues...7 3 Open Issues...8 Doc. Number: H70235 Revision: 001US 4

Overview of the Release 1.0 Overview of the Release 1.1 Introduction These provide a brief overview of the changes introduced into the Intel True Scale Fabric Switch 12000 for this release. References to more detailed information are provided where necessary. The information contained in this document is intended for supplemental use only; it should be used in conjunction with the documentation provided for each component. These list the new features, system issues closed since the previous release, as well as any known issues. 1.2 Audience The information provided in this document is intended for installers, software support engineers, hardware engineers, and service personnel. 1.3 If You Need Help If you need assistance while working with the Intel True Scale Fabric Switch 12000, contact your Intel approved reseller or Intel True Scale Technical Support: By E-mail: ibsupport@intel.com On the Support tab at web site: http://www.intel.com/truescale For OEM-specific server platforms supported by this release, contact your OEM. 1.4 New Features and Enhancements The following new features and enhancements have been made between Release 7.3.0.0.15 and 7.3.1.0.10: None 1.5 Installation Requirements There are no special or release-specific installation requirements for this release. 1.6 Changes to Hardware Support There are no release-specific changes to the hardware supported for this release. Doc. Number: H70235 Revision: 001US 5

Overview of the Release 1.7 Changes to Industry Standards Compliance There are no changes to the industry standards for this release. 1.8 Miscellaneous Different chassis types require different time intervals to fully reboot. The amount of time it takes a switch to reboot is dependent upon several factors, including: The type of reboot The number of leaves, spines and management modules in the chassis. Whether or not the switch chip firmware is being updated as a result of the reboot. Below are the maximum times that a chassis will take to reboot. In your environment you might see reboot times much less than these: 12200/12300-120 seconds 12800-040 220 seconds 12800-120 290 seconds 12800-180 350 seconds 12800-360 630 seconds At any point during the reboot, you can point a web browser to the chassis IP address, or telnet/ssh to the chassis IP address to see if the reboot has completed. The embedded version of the Intel Fabric Manager supports a maximum of 500 nodes. Intel products will auto-negotiate with devices that utilize IBTA-compliant autonegotiation. When attaching Intel products to a third-party device, the bit error rate is optimized if the third-party device utilizes attenuation-based tuning. For most configurations, using the default MTU size of 2K is recommended. The Intel True Scale Fabric Switch 12000 Series supports the following web browsers: Windows* Internet Explorer version 9.0 (for Windows 7) Windows Internet Explorer version 10.0 (for Windows 8) Windows Internet Explorer version 11.0.9 (for Windows 8.1) Mozilla Firefox* latest version (for Windows XP and Windows 7) Mozilla Firefox version 10 (for RHEL 6.4, and SLES11 SP2) Mozilla Firefox version 17.0.10 (RHEL 6.5) Mozilla Firefox version 17 (for SLES11 SP3, CentOS* 6.4 and 6.5, Scientific Linux* 6.4 and 6.5) Mozilla Firefox version 24.5.0 (for RHEL 7) Mozilla Firefox version 31 (for RHEL 6.6) 6 Doc. Number: H70235 Revision: 001US

Overview of the Release 1.9 Documentation Table 1-1 lists the end-user documentation for this release. All related documentation is available on the Intel download site. Documentation for Intel Partners is available at the vendors web site. Table 1-1. Related Documentation for this Release Document Title Intel Hardware Documents Intel True Scale 12000 Hardware Installation Guide Intel True Scale 12000 Users Guide Intel True Scale 12000 CLI Reference Guide Intel Adapter Hardware Installation Guide Intel OFED+ Documents Intel True Scale Fabric Software Installation Guide Intel OFED+ Host Software User Guide Intel OFED+ Host Software Intel IFS Documents Intel True Scale Fabric Suite FastFabric User Guide Intel True Scale Fabric Suite Fabric Manager User Guide Intel True Scale Fabric Suite FastFabric Command Line Interface Reference Guide Intel True Scale Fabric Suite Software Intel Fabric Viewer Documents Intel True Scale Fabric Suite Fabric Viewer Online Help Intel True Scale Fabric Suite Fabric Viewer Doc. Number: H70235 Revision: 001US 7

Bug Fixes 2.0 Bug Fixes Table 2-1 lists the fixes that have been made to the Intel True Scale Fabric Switch 12000: Table 2-1. Resolved Issues Release Product Description 7.3.1.0.10 Management Software Vulnerability to SSL 3.0 protocol called CVE-2014-3566 (aka "POODLE" or "Padding Oracle" on Downgraded Legacy Encryption) has been corrected. 7.3.0.0.15 S20 Transmit discards are no longer observed on inter switch links (ISLs). S20 S20 Nodes no longer experience intermittent communication failure within the fabric. Corrected an issue where malformed packets may not be properly handled, resulting in many TxDiscard messages. Corrected branding verbiage in Chassis Viewer. Vulnerability to CVE-2014-0224 has been corrected. GUI Embedded SW 7.2.1.1.16 IB Management Card S20 Corrected error recovery mechanisms. Adding a new SNMP Target Address with an Address Name that is 14 characters or longer and then rebooting no longer causes the switch to malfunction. 8 Doc. Number: H70235 Revision: 001US

Bug Fixes 2.1 Known Issues Table 2-2 lists the open issues for 7.3.1.0.10. Table 2-2. Open Issues Product/ Component Chassis Hardware Chassis Viewer GUI Chassis Hardware Chassis Viewer GUI Management Software Switch CLI Description Following a hot swap of a management module (MM) (with the part number 220055-001-C or earlier), the ATTN LED will occasionally flash once and the module does not boot. When using a web browser on a Linux* system and rebooting the switch, only two digits of the countdown time are displayed. If the countdown time is greater than 100, the ones column is not displayed, causing the countdown to appear to be proceeding very slowly (that is, decreasing 1 second every 10 seconds). Sometimes when inserting fiber optic cables (with the following part numbers) the warning message "QSFP fault condition" is logged in the switch log. CBL2-1000301-3-3.0M Fiber QSFP to QSFP. CBL2-1001001-3-10M Fiber QSFP to QSFP. CBL2-1003001-3-30M Fiber QSFP to QSFP. In a dual-management module (MM) setup, when rebooting either a slave or master MM using the Chassis Viewer GUI, the GUI takes much longer than normal to refresh itself. If updating from a previous release, and an SSH key with a length of greater than 511 bytes is present in the configuration, the firmware update will not be successful. Cable lengths of 0.5 meters are identified as 1 meter. Workaround Remove and reinsert the management module. Once the time remaining reaches 99 seconds, the counter will be displayed correctly. This message can be safely ignored. Rather than wait for the GUI countdown timer to complete, 100 seconds after rebooting the MM enter the chassis URL into the browser address bar. Either of the following two workaround options will avoid the issue: 1) As the switch is booting, interrupt the boot process and issue a factory 1 command from the serial port of the switch. For assistance using the factory 1 command, please contact Support. 2) Before booting the switch, use the CLI command sshkey rem to remove each of the SSH keys that have a length of greater than 511 bytes. For detailed CLI information, refer to the Intel True Scale 12000 CLI Reference Guide. None. Doc. Number: H70235 Revision: 001US 9