True Scale Fabric Switches Series

Similar documents
Intel True Scale Fabric Switches Series

Intel Cache Acceleration Software for Windows* Workstation

QLogic Family of QDR InfiniBand Switches. Table of Contents

How to Create a.cibd File from Mentor Xpedition for HLDRC

How to Create a.cibd/.cce File from Mentor Xpedition for HLDRC

Intel Atom Processor E3800 Product Family Development Kit Based on Intel Intelligent System Extended (ISX) Form Factor Reference Design

Intel Cache Acceleration Software - Workstation

Intel RealSense Depth Module D400 Series Software Calibration Tool

Intel RealSense D400 Series Calibration Tools and API Release Notes

Theory and Practice of the Low-Power SATA Spec DevSleep

Drive Recovery Panel

OpenCL* and Microsoft DirectX* Video Acceleration Surface Sharing

Intel Dynamic Platform and Thermal Framework (Intel DPTF), Client Version 8.X

Intel Embedded Media and Graphics Driver v1.12 for Intel Atom Processor N2000 and D2000 Series

Intel USB 3.0 extensible Host Controller Driver

Intel Cache Acceleration Software (Intel CAS) for Linux* v2.9 (GA)

HP BLc Intel 4X QDR InfiniBand Switch Release Notes. Firmware Version

Intel Open Source HD Graphics Programmers' Reference Manual (PRM)

Intel Atom Processor D2000 Series and N2000 Series Embedded Application Power Guideline Addendum January 2012

Intel Galileo Firmware Updater Tool

Intel Manycore Platform Software Stack (Intel MPSS)

Intel Core TM Processor i C Embedded Application Power Guideline Addendum

2013 Intel Corporation

Intel Atom Processor E6xx Series Embedded Application Power Guideline Addendum January 2012

Customizing an Android* OS with Intel Build Tool Suite for Android* v1.1 Process Guide

Intel Ethernet Controller I350 Frequently Asked Questions (FAQs)

The Intel SSD Pro 2500 Series Guide for Microsoft edrive* Activation

Intel Open Source HD Graphics, Intel Iris Graphics, and Intel Iris Pro Graphics

Product Change Notification

Bitonic Sorting. Intel SDK for OpenCL* Applications Sample Documentation. Copyright Intel Corporation. All Rights Reserved

Intel Manageability Commander User Guide

LED Manager for Intel NUC

Intel Core TM i7-4702ec Processor for Communications Infrastructure

Reference Boot Loader from Intel

Product Change Notification

OMNI-PATH FABRIC TOPOLOGIES AND ROUTING

Product Change Notification

Intel Integrated Native Developer Experience 2015 (OS X* host)

INTEL PERCEPTUAL COMPUTING SDK. How To Use the Privacy Notification Tool

IEEE1588 Frequently Asked Questions (FAQs)

Lustre Beyond HPC. Presented to the Lustre* User Group Beijing October 2013

HP BLc QLogic 4X QDR InfiniBand Switch Release Notes. Firmware Version

Product Change Notification

Intel Open Source HD Graphics. Programmer's Reference Manual

Product Change Notification

Data Plane Development Kit

Product Change Notification

Product Change Notification

Intel Omni-Path Fabric Manager GUI Software

Product Change Notification

Product Change Notification

Evolving Small Cells. Udayan Mukherjee Senior Principal Engineer and Director (Wireless Infrastructure)

Product Change Notification

Intel Desktop Board DZ68DB

Product Change Notification

Krzysztof Laskowski, Intel Pavan K Lanka, Intel

Product Change Notification

Intel Graphics Virtualization Technology. Kevin Tian Graphics Virtualization Architect

FABRIC PERFORMANCE MANAGEMENT AND MONITORING

The Intel Processor Diagnostic Tool Release Notes

Product Change Notification

Product Change Notification

Intel SDK for OpenCL* - Sample for OpenCL* and Intel Media SDK Interoperability

Specification Update. January 2014

Product Change Notification

Product Change Notification

Intel vpro Technology Virtual Seminar 2010

Using the Intel VTune Amplifier 2013 on Embedded Platforms

Product Change Notification

Desktop 4th Generation Intel Core, Intel Pentium, and Intel Celeron Processor Families and Intel Xeon Processor E3-1268L v3

Intel Omni-Path Fabric Switches

Product Change Notification

Data Center Efficiency Workshop Commentary-Intel

Software Evaluation Guide for ImTOO* YouTube* to ipod* Converter Downloading YouTube videos to your ipod

Product Change Notification

Product Change Notification

Product Change Notification

Intel Omni-Path Fabric Manager GUI Software

Product Change Notification

QLogic QDR InfiniBand Switch. Table of Contents

Intel 945(GM/GME)/915(GM/GME)/ 855(GM/GME)/852(GM/GME) Chipsets VGA Port Always Enabled Hardware Workaround

Intel 848P Chipset. Specification Update. Intel 82848P Memory Controller Hub (MCH) August 2003

Product Change Notification

Intel vpro Technology Virtual Seminar 2010

Sample for OpenCL* and DirectX* Video Acceleration Surface Sharing

Product Change Notification

Product Change Notification

Product Change Notification

Installation Guide and Release Notes

Product Change Notification

Intel Extreme Memory Profile (Intel XMP) DDR3 Technology

Ernesto Su, Hideki Saito, Xinmin Tian Intel Corporation. OpenMPCon 2017 September 18, 2017

Product Change Notification

Software Evaluation Guide for WinZip* esources-performance-documents.html

Product Change Notification

Product Change Notification

Product Change Notification

Product Change Notification

Intel 7510/7512 Scalable Memory Buffer

Intel G31/P31 Express Chipset

Transcription:

True Scale Fabric Switches 12000 Series Order Number: H53559001US

Legal Lines and Disclaimers INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. A "Mission Critical Application" is any application in which failure of the Intel Product could result, directly or indirectly, in personal injury or death. SHOULD YOU PURCHASE OR USE INTEL'S PRODUCTS FOR ANY SUCH MISSION CRITICAL APPLICATION, YOU SHALL INDEMNIFY AND HOLD INTEL AND ITS SUBSIDIARIES, SUBCONTRACTORS AND AFFILIATES, AND THE DIRECTORS, OFFICERS, AND EMPLOYEES OF EACH, HARMLESS AGAINST ALL CLAIMS COSTS, DAMAGES, AND EXPENSES AND REASONABLE ATTORNEYS' FEES ARISING OUT OF, DIRECTLY OR INDIRECTLY, ANY CLAIM OF PRODUCT LIABILITY, PERSONAL INJURY, OR DEATH ARISING IN ANY WAY OUT OF SUCH MISSION CRITICAL APPLICATION, WHETHER OR NOT INTEL OR ITS SUBCONTRACTOR WAS NEGLIGENT IN THE DESIGN, MANUFACTURE, OR WARNING OF THE INTEL PRODUCT OR ANY OF ITS PARTS. Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined". Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The information here is subject to change without notice. Do not finalize a design with this information. The products described in this document may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request. Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order. Copies of documents which have an order number and are referenced in this document, or other Intel literature, may be obtained by calling 1-800-548-4725, or go to: http://www.intel.com/design/literature.htm Intel and the Intel logo are trademarks of Intel Corporation in the U.S. and/or other countries. *Other names and brands may be claimed as the property of others. Copyright 2014, Intel Corporation. All rights reserved. 2 Order Number: H53559001US

Contents 1.0 Overview of the Release...4 1.1 Introduction...4 1.2 Audience...4 1.3 If You Need Help...4 1.4 New Features and Enhancements...4 1.5 Installation Requirements...4 1.6 Changes to Hardware Support...4 1.7 Changes to Industry Standards Compliance...4 1.8 Miscellaneous...5 1.9 Documentation...5 2.0 Bug Fixes...6 2.1 Known Issues...7 Tables 1 Related Documentation for this Release...5 2 Resolved Issues...6 3 Open Issues...7 Order Number: H53559001US 3

1.0 Overview of the Release 1.1 Introduction These provide a brief overview of the changes introduced into the True Scale Fabric Switch 12000 for this release. References to more detailed information are provided where necessary. The information contained in this document is intended for supplemental use only; it should be used in conjunction with the documentation provided for each component. These list the new features, system issues closed since the previous release, as well as any known issues. 1.2 Audience The information provided in this document is intended for installers, software support engineers, hardware engineers, and service personnel. 1.3 If You Need Help If you need assistance while working with the True Scale Fabric Switch 12000, contact your Intel approved reseller or Intel True Scale Technical Support: By E-mail: ibsupport@intel.com On the Support tab at web site: http://www.intel.com/truescale For OEM-specific server platforms supported by this release, contact your OEM. 1.4 New Features and Enhancements The following new features and enhancements have been made between Release 7.2.1.1.16 and 7.3.0.0.15: None 1.5 Installation Requirements There are no special or release-specific installation requirements for this release. 1.6 Changes to Hardware Support There are no release-specific changes to the hardware supported for this release. 1.7 Changes to Industry Standards Compliance There are no changes to the industry standards for this release. Order Number: H53559001US 4

1.8 Miscellaneous Different chassis types require different time intervals to fully reboot. The amount of time it takes a switch to reboot is dependent upon several factors, including: The type of reboot The number of leaves, spines and management modules in the chassis. Whether or not the switch chip firmware is being updated as a result of the reboot. Below are the maximum times that a chassis will take to reboot. In your environment you might see reboot times much less than these: 12200/12300-120 seconds 12800-040 220 seconds 12800-120 290 seconds 12800-180 350 seconds 12800-360 630 seconds At any point during the reboot, you can point a web browser to the chassis IP address, or telnet/ssh to the chassis IP address to see if the reboot has completed. The embedded version of the Intel Fabric Manager supports a maximum of 500 nodes. Intel products will auto-negotiate with devices that utilize IBTA-compliant autonegotiation. When attaching Intel products to a third-party device, the bit error rate is optimized if the third-party device utilizes attenuation-based tuning. For most configurations, using the default MTU size of 2K is recommended. The True Scale Fabric Switch 12000 Series supports the following web browsers: Windows Internet Explorer version 9.0 (for Windows 7) Windows Internet Explorer version 10.0 (for Windows 8) Mozilla Firefox latest version (for Windows XP and Windows 7) Mozilla Firefox version 10 (for RHEL 6.4, and SLES11 SP2) Mozilla Firefox version 17.0.10 (RHEL 6.5) Mozilla Firefox version 17 (for SLES11 SP3, CentOS 6.4 and 6.5, Scientific Linux 6.4 and 6.5) Mozilla Firefox version 24.5.0 (for RHEL 7) 1.9 Documentation Table 1 lists the Release 7.3 related documentation. All related documentation is available on the Intel download site. Documentation for Intel Partners is available at the vendors web site. Table 1. Related Documentation for this Release Document Title Intel Hardware Documents Intel True Scale 12000 Hardware Installation Guide Intel True Scale 12000 Users Guide Order Number: H53559001US 5

Table 1. Related Documentation for this Release (Continued) Document Title Intel True Scale 12000 CLI Reference Guide Intel Adapter Hardware Installation Guide Intel OFED+ Documents Intel True Scale Fabric Software Installation Guide Intel OFED+ Host Software User Guide Intel OFED+ Host Software Intel IFS Documents Intel True Scale Fabric Suite FastFabric User Guide Intel True Scale Fabric Suite Fabric Manager User Guide Intel True Scale Fabric Suite FastFabric Command Line Interface Reference Guide Intel True Scale Fabric Suite Software Intel Fabric Viewer Documents Intel True Scale Fabric Suite Fabric Viewer Online Help Intel True Scale Fabric Suite Fabric Viewer 2.0 Bug Fixes Table 2 lists the fixes that have been made to the True Scale Fabric Switch 12000: Table 2. Resolved Issues Release Product Description 7.3.0.0.15 S20 Transmit discards are no longer observed on inter switch links (ISLs). S20 S20 GUI Embedded SW 7.2.1.1.16 IB Management Card S20 Nodes no longer experience intermittent communication failure within the fabric. Corrected an issue where malformed packets may not be properly handled, resulting in many TxDiscard messages. Corrected branding verbiage in Chassis Viewer. Vulnerability to CVE-2014-0224 has been corrected. Adding a new SNMP Target Address with an Address Name that is 14 characters or longer and then rebooting no longer causes the switch to malfunction. Corrected error recovery mechanisms. Order Number: H53559001US 6

2.1 Known Issues Table 3 lists the open issues for 7.3.0.0.15. Table 3. Open Issues Product/ Component Chassis Hardware Chassis Viewer GUI Chassis Hardware Chassis Viewer GUI Management Software Switch CLI Description Following a hot swap of a management module (MM) (with the part number 220055-001-C or earlier), the ATTN LED will occasionally flash once and the module does not boot. When using a web browser on a Linux system and rebooting the switch, only two digits of the countdown time are displayed. If the countdown time is greater than 100, the ones column is not displayed, causing the countdown to appear to be proceeding very slowly (that is, decreasing 1 second every 10 seconds). Sometimes when inserting fiber optic cables (with the following part numbers) the warning message "QSFP fault condition" is logged in the switch log. CBL2-1000301-3-3.0M Fiber QSFP to QSFP. CBL2-1001001-3-10M Fiber QSFP to QSFP. CBL2-1003001-3-30M Fiber QSFP to QSFP. In a dual-management module (MM) setup, when rebooting either a slave or master MM using the Chassis Viewer GUI, the GUI takes much longer than normal to refresh itself. If updating from a previous release, and an SSH key with a length of greater than 511 bytes is present in the configuration, the firmware update will not be successful. Cable lengths of 0.5 meters are identified as 1 meter. Workaround Remove and reinsert the management module. Once the time remaining reaches 99 seconds, the counter will be displayed correctly. This message can be safely ignored. Rather than wait for the GUI countdown timer to complete, 100 seconds after rebooting the MM enter the chassis URL into the browser address bar. Either of the following two workaround options will avoid the issue: 1) As the switch is booting, interrupt the boot process and issue a factory 1 command from the serial port of the switch. For assistance using the factory 1 command, please contact Support. 2) Before booting the switch, use the CLI command sshkey rem to remove each of the SSH keys that have a length of greater than 511 bytes. For detailed CLI information, refer to the Intel True Scale 12000 CLI Reference Guide. None. Order Number: H53559001US 7