This Datasheet for the IC660BBD110. Block 115Vac Input 16 Circuits.

Similar documents
This Datasheet for the IC660BBD101. Block 115Vac I/O Low Leakage 8 Circuits.

This Datasheet for the IC660BBD025. Block 5/12/24Vdc Sink I/O 32 Circuits.

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

This Datasheet for the IC660BBR100. Block Relay Output Normally Closed 16 Circuits.

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

This Datasheet for the IC660BBA020. Block 24/48Vdc Analog 4 Inputs / 2 Outputs.

This Datasheet for the IC660BBA101. Block 115Vac/125Vdc RTD Input 6 Channels.

This Datasheet for the IC660BBS103. Block 115Vac/125Vdc Low Leak Isolated I/O, w/o Failed SW Diagnostics, 8 Circuit.

This Datasheet for the IC660BBD022. Block 24Vdc Source I/O 16 Circuits, 2/3 Wire Sensor Compatible

This Datasheet for the IC660BBA103. Block 115Vac/125Vdc Thermocouple Input 6 Channels.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT.

This Datasheet for the IC697BEM733. Series Genius Remote I/O Scanner.

This Datasheet for the IC670MDL /24VDC 0.5A Output Pos. Logic 16 Pt. Grouped.

This Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped.

PACSystems RX7i IC698CHS009/119

PLC Racks IC697CHS782/783

This Datasheet for the IC697BEM721. I/O Link Interface Module for the Series

Analog Voltage Combination Module

This Datasheet for the IC670MDL VAC 8 Pt. Isolated Input.

This Datasheet for the IC660BSM120. BUS Switching Module 115Vac/125Vdc.


This Datasheet for the IC697BEM731. Series Genius I/O Bus Controller.

This Datasheet for the IC670MDL VAC 16 Pt. Input Grouped.

IC693 PLC IC693ACC350, IC693ACC340/341

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

PM Series Power Meter

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

InView Marquee Message Display

PanelView Plus/VersaView CE Terminals and Display Modules

PACSystems* RX3i Genius* Communications Gateway, IC695GCG001. Quick Start Guide, GFK-2891C August 2016

Instructions to printer DO NOT PRINT THIS PAGE

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

This Datasheet for the IC670MDL VDC Pos/Neg Logic Input 16 Pt. Grouped.

Shown with terminal block Supports diagnostic point fault contacts in the logic program

ALS c en Alspa CE80 20 N80 Bus Interface Unit User s Manual

PACSystems* RX3i IC695PSA140

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

Digital ac/dc (24V) Input Module

Analog Input Installation Manual

H704-42(H)(E), H704-42/1(H)(E)

Suprex RS-485 SPX-7500 Wired Reader-Extender

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

AC Input /AC Output. Module

SNAP-IT-PM Installation Guide

INSTALLATION MANUAL SLI 50 INVERTER

16-Channel Digital Output Module 120Vac/dc

Analog Input, 16-Bit Thermocouple Module

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

GE Intelligent Platforms Programmable Control Products PACSystems* RX3i DNP3 Slave Module IC695EDS001. Quick Start Guide GFK-2912 October 2014

PACSystems* RX3i IC695PSA040

Discrete Input Modules IC697MDL653

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

PS/IO Circuit Board Retrofit

This Datasheet for the IC670ALG310. Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter

This Datasheet for the IC670MDL VDC 2A Output Pos. Logic 8 Pt. Electronic Short Circuit Protect

Lightning Stitch Assembly

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication

Analog Monitor Installation Manual

BCM2 Series Branch Circuit Monitors Quick Setup Guide

Installing the Cisco AS5400XM Universal Gateway

THE CTB08D LIGHT CONTOLLER

INSTALLATION INSTRUCTIONS

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

Ink-Dot Series II Driver

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

Power Supply and Fan Module Installation

VersaMax* Analog Input, 16-Bit Thermocouple Module

MT8050iE series. Installation Instruction (1) (2)

Unpacking an Epica Distribution Matrix

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

5504 Thermocouple Analog Input Module

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

EX-RC1 Remote I/O Adapter

SNAP-IT-1U Installation Guide

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

ABM International, Inc. Lightning Stitch Checklist 9/13/2013

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

Installing the IPS 4345 and IPS 4360

24 Input/8 Output AC Block I/O Module

PV Rapid Shutdown device

Programmable Controller IC697ACC721/724/744

Dell SC7020 Storage Controller Getting Started Guide

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

LED W RGBA User Manual

Serial Data DIN Fiber Link System

BMX DDM Mixed Relay Input/Output module

PACSystems RX3i IC695PSA140

Four opto-isolated signal channels: SD, RD, RTS, and CTS. Electrical compatibility with RS-485. A 5V DC/DC converter for power isolation

TABLE OF CONTENTS 1. OVERVIEW... 1

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

Transcription:

This Datasheet for the IC660BBD110 Block 115Vac Input 16 Circuits http://www.cimtecautomation.com/parts/p-14435-ic660bbd110.aspx Provides the wiring diagrams and installation guidelines for this GE Series 90-30 module. For further information, please contact Cimtec Technical Support at 1-866-599-6507 sales@cimtecautomation.com

Description The 115VAC Discrete Input Block (IC66*BBD110) is an intelligent, configurable module that provides an interface to 115VAC discrete input sensors. The block has sixteen 115VAC circuits - two banks of eight circuits each. Typical inputs to this block are contact closures from switches, pushbuttons, or limit switches. The block can be used with both 2- wire and 3-wire proximity switch inputs. Control power for the block comes from the power line that supplies the inputs. o separate block power supply is needed. Features Block features include: Selectable thresholds Advanced diagnostics Software Configurable Features 115V 50/60 z Input The 16 Circuit 115 VAC Input Block provides configurable detection of Open Wire and Shorted Wire faults. Selectable thresholds extend the use of Open Wire and/or Shorted Wire diagnostics to circuits with many types of input devices and sensors. There are separate On/Off thresholds for each group of eight inputs. On/Off thresholds are configurable from 25% to 85% of the incoming line voltage, allowing the use of a wide variety of input sensors. Optional Open Wire detection can be selected for individual inputs. The Open/Off threshold can also be configured at 25% to 85% of the incoming line voltage. Separate Open/Off thresholds can be selected for each group of eight inputs. Optional Short Circuit detection at 10% and 90% of the incoming line voltage can also be selected for individual inputs. For most applications, the default thresholds and recommended resistor values are not changed. Fault reporting can also be enabled or disabled circuit-by circuit. Specifications Catalog umbers Block type Block Electronics Terminal Block Specifications Size (height x width x depth) Weight LEDs (I/O Block) LEDs (each circuit) Input to ground or serial bus Isolation eat Dissipation Operating voltage (single source) Frequency Required power (block only) Terminal board rating (input or feed-through current) Power supply dropout time Input Specifications 16 circuits, inputs only IC66*BBD110 IC66*EBD110 IC66*TBD110 8.83 (22.44cm) x 3.34 (8.48cm) x 3.91 (9.93cm) 4 lbs. (1.8 kg) Unit OK, I/O Enabled Reflect state of input (logic side) 1500V 28 Watts maximum with 16 inputs on at full current 93-132VAC 47-63 z 80mA max. block current plus 200mA max. input circuit current 5.0 Amps 1 cycle (16.7ms at 60z, 20ms at 50z) Input off state, input on state Programmable threshold (25% to 85%) Input impedance (typical) 11.6K Ohms Input open wire Programmable threshold (25% to 85%) Input shorted wire Input processing time (typ) Selectable input filter times Input diagnostics Environmental Specifications Fixed 10%-90% thresholds 1ms (plus selectable filter time) 10 to 100ms in 10ms increments Open Wire, Short Circuit Operating temperature 0 C to +60 C (+32 to +140 F) Storage temperature -40 to +100 C (-40 to +212 F) umidity Vibration 5% to 95% (non-condensing) 5-10 z 0.2 (5.08mm) displacement, 10-200 z at 1G Refer to GFK-0867 for product standards and general specifications. Using this Datasheet This datasheet summarizes information about block installation, configuration, and diagnostics. Your primary reference should be the Discrete and Analog Blocks User s Manual. It includes detailed instructions for block installation and configuration. For additional information about systems and communications, including bus specifications, refer to the I/O System and Communications Manual. 1

Compatibility This block is fully compatible with and-held Monitor model IC66*M501 only. If the block is at either end of the bus, connect a terminating resistor of the appropriate type (see the System and Communications User s Manual for details) across its Serial 1 and Serial 2 terminals. Installation Instructions Carefully inspect all shipping containers for damage. If any equipment is damaged, notify the delivery service immediately. Save the damaged shipping container for inspection by the delivery service. After unpacking the equipment, record all serial numbers. Save the shipping containers and packing material in case it is necessary to transport or ship any part of the system. Terminating Resistor Serial 1 Serial 2 Shield In Shield Out Start of Bus End of Bus Terminating Resistor Serial 1 Serial 2 Shield In Shield Out Block Mounting Genius I/O blocks are considered "open equipment" and therefore must be installed within a protective enclosure. They should be located in an area that is clean and free of airborne contaminants. There should be adequate cooling airflow. The block can be mounted right side up, or upside down. Leave at least 2 inches of space between blocks. Mount the block by drilling two screw or bolt holes for 8-32 hardware. Position the block so that the notches in the upper and lower flanges line up with the mounting holes. Mount the block using 8-32 screws. Use star washers to provide ground integrity. Grounding The block s mounting screws must not be used as the only means of grounding the block. Connect the green ground screw on the block to a reliable ground system using a short wire lead, minimum size AWG #12 (avg 3.3mm 2 in cross-section). Warning If mounting screws do not make good ground connection and the ground screw is not connected to a reliable ground, the block is not grounded. Electrical shock hazard exists. Death or personal injury may result. Block Wiring Do not overtorque the terminal screws. Recommended torque for all terminals is 6 in/lb (.678 /M). Serial Bus Wiring Terminals 1 to 4 are for the serial bus. These terminals accept one AWG #12 wire (avg 3.3mm 2 cross-section) or two AWG #14 wires (each avg 2.1mm 2 in cross-section). The minimum recommended wire size is AWG #22 (avg.36mm 2 in cross-section). Terminals 1-4 can also accommodate spade or ring terminals up to 0.27 inch (6.85mm) wide with a minimum opening for a #6 screw, and up to 0.20 inch (5.1mm) depth from the screw center to the back barrier. Be sure unshielded wire ends are not longer than 2 inches (5 cm). Using one of the cable types recommended in the System and Communications User s Manual, connect the serial bus to terminals 1-4. 1 2 3 4 SERIAL 1 SERIAL 2 SIELD I SIELD OUT Field Wiring Terminals 5 to 32 are for field devices. They take a single wire up to AWG #14 (avg 2.1mm 2 in cross-section). Minimum recommended size is AWG #20 (avg.54mm 2 in cross-section). 115 VAC 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 I1 I2 I3 I4 I5 I6 I7 I8 I9 I10 I11 I12 I13 I14 I15 I16 Run one signal wire for each device. Returns can be made to one or more of the terminals; all terminals are internally bussed, as are the terminals. Extra power terminals are for convenience. Depending on layout and current loads, hot connections can be bussed together and made by one wire back to the block or power source. eutral connections can also be bussed and made with one wire. Power Source Wiring Connect the hot side of a 115 VAC source to an terminal and the neutral to an terminal. The power supply should not be fused higher than 5A. Do not daisy-chain the power bus to other blocks or devices through the extra and terminals. These terminals are for wiring convenience only; using them as power distribution points may result in damage to the block. Make all block power connection to the same 120 VAC phase. Other blocks can use different phases. 2

Power Disconnects Since block power is the same as circuit power, it is important to wire block power disconnects so that block power and input power will be removed at the same time. YES O LOAD AC BLOCK Removing an Electronics The block s Electronics can be replaced with a compatible model without removing field wiring or reconfiguring the block. Retaining Screws (Qty. 2) Electronics If I/O circuit power is not removed at the same time as block power, the block may power up when multiple inputs are activated, even though one leg of power has been removed from the block. If you want to disable the block without removing power from input devices, use a Block Puller to unplug the Electronics. Do not disconnect or to remove power. Terminal Connector Pins Wiring for Shorted Wire Detection If a circuit will use the configurable Shorted Wire detection feature, it may be necessary to install a resistor in series with the input device. For the default thresholds and a dry contact sensor, use a 3.9K ohm resistor. If the thresholds are changed, the resistor value must be selected as described in the Discrete and Analog Blocks User s Manual. For some solid state sensors, additional external resistance may not be required. Consult the sensor manufacturer s specifications. Rs I Wiring for Open Wire Detection If a circuit will use the configurable Open Wire detection feature, it may be necessary to install a resistor across the terminals of the input device. For dry contact sensors, the default thresholds are not changed and a 22K ohm resistor can be used. If the thresholds are changed, a resistor must be selected as described in the Discrete and Analog Blocks User s Manual. For some solid state sensors, additional external resistance may not be required. Consult the sensor manufacturer s specifications. I Rp 1. Unscrew the retaining screws at the top and bottom of the block. 2. Using a Block Puller (IC660BLM507), engage the tabs in the first vent slots. Move the tool to the center of the block and squeeze the handle. 3. Pull the Electronics upward. Warning If power is applied to the field terminals, power is also exposed on the connector pins at the base of the Terminal, and electrical shock hazard exists. Do not touch the connector pins! Death or injury may result. Inserting an Electronics 1. Align the Electronics in the guides and push down firmly. Do not exert excessive force; it may damage the block. 2. If unusual resistance is met, remove the Electronics. If power is applied to the block, DO OT TOUC TE COECTOR PIS! Inspect the Terminal, connector receptacle, and connector edge board (on the Electronics ). Be sure the keying matches. Remove any obstacles and reinsert the Electronics. Pay close attention to the alignment of the guide pins. 3. Secure the Electronics with the screws on the top and bottom of the Terminal. Open Wire and Shorted Wire diagnostics can be selected for the same input. The input circuit must then include both a series resistor and a parallel resistor to detect Open/Short conditions from a dry contact sensor. If the block s default thresholds will be used, use the resistor values given above. I Rs Rp 3

Block Operation Each circuit has its own LED that indicates the presence of On/Off threshold voltage. Vsource 115 VAC Input Device Vin Field Connections 47K 11.6K Terminal Voltage Sensing Circuits Electronics Internal +5V Processor The block s input circuitry is resistive. The resistive load is sufficient to activate most 2-wire proximity switch devices. Input resistance is 11.6K Ohms, which provides a preload current of 9.9 ma at 115 volts. LEDs The Unit OK and I/O Enabled LED s show the operating status of the block. Unit OK I/O Meaning Enabled O O Block functioning, CPU communicating O OFF Block functioning o CPU communications for 3 bus scans O Blinking Block functioning, Circuit forced Blinking O Circuit fault, CPU communicating Blinking OFF Circuit fault o CPU communications for 3 bus scans OFF Don t Care o block power, or block faulty Alternate Blinking Circuit fault, Circuit forced Synchronous Blinking o CPU communications - block number conflict Circuit LEDs indicate the presence of On/Off threshold voltage. Diagnostics Open Wire and Shorted Wire diagnostics can be enabled separately or together. Each requires the addition of a resistor at the input device as shown previously. The Discrete and Analog I/O Blocks User s Manual explains how to configure these diagnostics, and how to select the correct resistor for the application. Open Wire: indicates an open wire from a sensor to the input terminals on a tri-state input. If this fault occurs, the block sets the input state to 0 in the CPU. Shorted Wire: indicates a shorted wire to or. The block sets the CPU s input state to 1 if the fault is short high or 0 if the fault is short low. A short between In and may result in high fault currents when the input switch is closed. This may blow the line fuse or cause overheating of series resistor R s. Configuration First, the block must be configured with a and-held Monitor to: Enter its Device umber (serial bus address). Enter its Reference umber (required only for IC600 and IC550 series PLCs only). The rest of the features can be configured either using a and-held Monitor, or by sending a Write Configuration datagram to the block from the host. ote: If a block is configured offline, it must be properly grounded and have a 75 Ohm resistor installed across its Serial 1 and Serial 2 terminals. See the Discrete and Analog I/O Blocks User s Manual for instructions. Feature Circuit or Block Factory Setting Selections Device umber Block null 0 to 31 (a number must be selected) Reference Address Block none Depends on host CPU type Baud Rate Block 153.6 std 153.6 std, 153.6 ext, 76.8, 38.4 Kbd Input Filter Time 8* 10ms 10 to 100ms Open/Off 8* 25% 25-85% Threshold On/Off Threshold 8* 50% 25-85% Short Detect Circuit no yes, no Open Detect Circuit no yes, no Report Faults Circuit yes yes, no Configuration Protection Block disabled enabled, disabled * Set up separately for each bank of circuits (1-8 and 9-16) 4