Installation Guide V1.2

Similar documents
Variable Air Management System. Installation Guide V1.1

Quick Start. MyAir4 User Manual. This section will give you a brief description about each of the buttons found on the home screen.

Introduction. MyAir5 User Guide

Failure to follow WARNING is very likely to result in such grave consequences as death or serious injury

Welcome to the Connected Home. Installation Guide V1.1

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

AirTouch 3 Zone Control System

Smart Home Systems. User Manual V1.3

CoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems

AirTouch 2 Zone Control System

Central Controller Operation & Installation Manual

CoolPlug CooLinkHub HVAC Bridge. Quick Installation Guide

CoolMasterNet Technical Data CoolMasterNet Universal Interface Adapter for HVAC Systems

Smart Home Systems. User Manual V2.0

Advantage Air Status Codes End User

ZONETOUCH DAMPER CONTROL SYSTEM Operation Manual

izone 400 to 435 Air Conditioning Control Systems

WELCOME. For customer support or any inquiries, please visit our web site at or contact us at

OPERATION INSTRUCTIONS

Home Screen...4. Quick Start Guide...5. MyAir Standalone Zone Controls only...5. MyAir Zone Controls With Integrated Unit On/Off Control...

Table of Contents. e-zone User Manual

ADVANCED TECHNICAL MANUAL AAC1 SMALL SYSTEM CONTROL CONSOLE. Redefine your comfort zone.

If you require more information about your controllers features or functions, please follow below links;

basicdim Wireless Wireless module for basicdim

Lighting Controls and Connectivity basicdim. basicdim Wireless Passive Module Wireless module for basicdim

Note: Clean Work area of all or any debris after Repair.

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

Biometric finger print entry system.

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication

INSTALLATION MANUAL Wired Remote Control

XTS36 Touch Screen X10 Lighting Control System Operating Manual

STEWARD Home Automation Application

IS-IR-WIFI-1 User Manual

INSTALLATION MANUAL. Remote controller BRC315D7

MAKING MODERN LIVING POSSIBLE. Installation Guide. Twin Kit 086L

INSTALLATION & USER MANUAL

ACTRONCONNECT Wireless control of your air conditioner at your fingertips.

REMOVE COVERS. 1. Remove three screws from the Side Panel (L). 2. Slide the Side Panel (L) backward, and raise it to remove from the printer.

INSTALLATION MANUAL For authorized service personnel only.

aeria aerialb x - ultra ultra User Manual

Casambi App FAQ

Table of Contents CHAPTER 1: FCC WARNINGS... 7 CHAPTER 2: SAFETY INSTRUCTIONS... 9

VT8600 Series Installation Guide. Rooftop Unit, Heat Pump and Indoor Air Quality Controller

KNX is a European Standard Protocol used for household and industrial Buliding Management System (BMS).

MM-A20 BMS Interface for Mitsubishi Electric Split Air-Conditioning

MCS-TOUCHSCREEN Auto Disk Clean up

3. Alignment and Adjustments

INTRODUCTION Busch-SmartTouch KNX. The 7 SmartTouch

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

Installation, Start-up and Operating Instructions

Electronic data system application end user manual

Operation Guide CT32 ENGLISH

CITRIX NAVIGATION & ACCESSING myhr

DK-AC-KNX-1. Specifications. Main features. Info

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs

Mini Mini GlobiLab Software Quick Start Guide

Robot Light V2. User Manual

AFCS Fluid Guard 2 Model

Elevation Window Control System

Home Monitoring and Control service provided by Verizon Online LLC

IntesisBox PA-AC-MBS-1

Tracksa Light Marshal User Manual

Software Installation Guide. Version 1.1

USER S MANUAL. DAS-G01 The Power of Tomorrow

Veris Sensors App. Quick Start Guide Pressure Monitoring. For Use with Differential Pressure / Air Velocity Transducers. Introduction.

INNOV.NET PTY LTD. User guide

USER MANUAL. 7" Intelligent Digital Video Doorphone Indoor Unit TIP-DPH-INT7. Product Overview Product Description

INTRODUCTION...1 FEATURES...1 PACKAGE CONTENTS... 1 TECHNICAL SPECIFICATIONS...2 SYSTEM REQUIREMENT..3 CABLE DIAGRAMS.3 PRODUCT DETAILS 4

INNOV.NET PTY LTD. User guide

DAIKIN Internet remote control unit

VIRON CONNECT POOL AND SPA CONTROLLER

Two remote controller system with one Lossnay Basic System (Refer to page C-10) Multiple Lossnay units with one remote controller.

IntesisBox Modbus Server - LON

SmartHome Management Guide for Tenant V

CB17 CONTROL SYSTEM USER MANUAL

7. PCB AND FUNCTIONS

Product Manual. Surge Protected Metal 7- Port USB 2.0 Hub DIN RAIL Mount Kit NEC Chip

Graphical User Interface V1.0.3

LED controllers. ZUPP Property Group, Qld. With the revolution in LED Lighting, comes the need for control.

Setup Instructions for Upgrading the Windows XP Panasonic CF-19 Toughbook to Windows 7

IntesisBox. for EnOcean

M A C 3 Wind Speed Alarm & Controller

CONTROLLER INSTALLATION OPERATION & QUICK START

HydroGuard Expert Pool Manual

Automate Pulse Set-Up Instructions

Nextiva S4300-BR. Installation Guide

USER HELP GUIDE. NOTE: We suggest that the user s device be upgraded to the most current version.

The Otto Home Control app allows for control of your motorized window coverings through your smartphone/tablet

All your entertainment in one place

IO-INTERFACE. Procon. INSTALLATION MANUAL Version 1.01 MITSUBISHI ELECTRIC FOR INSTALLERS

Samsung SmartThins Wifi ET-WV525. Samsung SmartTings Wifi Pro ET-WV535. User Manual

PRODUCT INFORMATION MANUAL SECTION: 7-I POWERVIEW MOTORISATION OVERVIEW HELLO POWERVIEW MOTORISATION OVERVIEW

VRF Control System. Judy Ouyang Technical Support Engineer

For more information, visit User Manual

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

OneControl Tablet OWNER'S MANUAL. Rev: Page 1 OneControl Tablet Owner's Manual

Virtual Keypad App Help Last update: 2017/02/02

INTELLI-HOOD TROUBLESHOOTING GUIDE

16 Port USB 3.0 Metal Hub w/surge Protection Rack/DIN-RAIL Mountable Coolgear, Inc. Version 1.1 September 2017 Model Number:

Please take serious note of the following warnings:

Transcription:

+ Welcome to the Connected Home Installation Guide V1.2

MyAir Installation Guide Contents 1 - SYSTEM OVERVIEW 2 - OVERVIEW 3 - COMPATIBILITY 4 - SETUP 5 - DAIKIN ( DK) SETUP 6 - FUJITSU ( FJ) SETUP 7 - LG ( LG) SETUP 8 - MITSUBISHI ELECTRIC ( ME) SETUP 9 - SAMSUNG ( BDSAM) SETUP 10 - PANASONIC ( PA) SETUP 11 - TOSHIBA ( TO) SETUP 12 - HITACHI ( HIT) SETUP 14 - MITSUBISHI HEAVY IND. ( MHI) 15 - SYSTEM CONFIGURATION 2 3 4 5 7 8 8 9 9 10 11 12 13 14 installation guide 17 Installation Guide V1.2 1

Favourites Groups Scenes SetUp Help 1 - SYSTEM OVERVIEW Master Favourites Master WIR Ensuite Hall Way Entry Rocco Jade Bathroom Guest Kitchen Dining Living Indoor Unit OR CM / SAM OTHER EXT MY+ RF Wall Sensor (if installed) Zone Motor 10x Zone Motors [CLIP24] EXT TOUCH MY+ SCREEN CB CB EXT MY+ EXT 8 NA MyAir+ Only MyLights LM (if installed) Wired Wall Sensor (if installed) PART NO. OPTIONS DESCRIPTION DK / FJ / LG / ME / PA / BDSAM / TO / MHI / HIT Control Box - Extender (MyLights + WSW) CLIP24 - Zone Motor - AC + DC Power Supply WSRF - Wall Sensor RF (Wireless) WSW - Wall Sensor Wired TSP7 8 Wall Mounted Touchscreen V7 Only use approved components as listed here. Any unauthorised changes to system components may pose a safety risk, make the product non-compliant with safety standards and any failure may not be covered by manufacturer s warranty. Installation Guide V1.2 2

2 - OVERVIEW Below is the control box with each of its ports and setting switches labled. System ID Dipswitch Settings Dipswitch TSP Tablet Connection NA (MyAir+ only) Connection (Used for wired wall sensors) Power Supply Connection () EXT MY+ TOUCH SCREEN Link to Indoor Unit CM / SAM OTHER 2 Pin Samsung / Carrier / Midea 4 Pin Daikin / Fujitsu / LG / Mitsubishi / Samsung / Panasonic Zone Motors 1-10 Antenna Location (Used for RF wall sensors) Installation Guide V1.2 3

3 - COMPATIBILITY The following table lists the air conditioner brands that the supports. Some brands require a special version of the in order to communicate with their units. The part numbers are listed in the second column. BRAND CB PART NO. CABLE CARRIER 2 PIN DAIKIN DK 4 PIN FUJITSU FJ 4 PIN LG LG 4 PIN MIDEA 2 PIN MITSUBISHI ELEC ME 4 PIN MITSUBISHI HEAVY IND. MHI 4 PIN PANASONIC PA 4 PIN SAMSUNG ( 14KW ) 2 PIN SAMSUNG ( 16KW) BDSAM 4 PIN TOSHIBA TO 4 PIN HITACHI HIT 4 PIN HAIER 2 PIN RINNAI 2 PIN Installation Guide V1.2 4

4 - SETUP The standard Control Box will control units from the following suppliers: Carrier; Midea; Rinnai; Haier or Samsung (14kW or less.) The setup uses a SAM cable for Samsung, Rinnai and Haier units and a CM cable for the Carrier and Midea units. Setup for Samsung units: 1. Ensure power to the air conditioner is OFF. 2. Connect Samsung Remote (MWR-WE10), then turn power ON. 3. Configure static pressure using manufacturers instructions. Run unit in cooling / heating to test, then power OFF. 4. Disconnect the Samsung remote from the indoor unit and replace with SAM cable. Connect the other end of the SAM cable to the CB. CABLE CORE COLOUR RED BLACK INDOOR UNIT TERMINAL F4 F3 5. Go to Section 15 SYSTEM CONFIGURATION to complete install. Setup for Carrier / Midea units: 1. Ensure power to the air conditioner is OFF. 2. Connect the CM cable from the CB to the connector in the indoor unit that is used for the standard Carrier / Midea controller. 3. Connect the ground cable to the indoor unit chassis. 4. On the indoor unit PCB set the 2 dip switches labeled SW1 and SW2 to the positions shown. Switch Value ON 1 2 ON 1 SW1 1 2 OFF ON SW1 SW2 SW2 1 ON 5. Go to Section 15 SYSTEM CONFIGURATION to complete install. See over page for Rinnai and Haier setup... Installation Guide V1.2 5

SETUP Setup for Rinnai units: 1. Ensure power to the air conditioner is OFF. 2. Connect Rinnai remote, then turn power ON. 3. Run unit in cooling / heating to test, then power OFF. 4. Disconnect the Rinnai remote from the indoor unit and replace with SAM cable. Connect the other end of the SAM cable to the CB. CABLE CORE COLOUR RED BLACK INDOOR UNIT TERMINAL CN29-X CN29-Y 5. Go to Section 15 SYSTEM CONFIGURATION to complete install. Setup for Haier units: 1. Ensure power to the air conditioner is OFF. 2. Connect Haier remote, then turn power ON. 3. Run unit in cooling / heating to test, then power OFF. 4. Follow Haier instructions and connect a YCJ-A002 Modbus adapter board (supplied by Haier) to the indoor unit. Then connect the SAM cable to the CB and then wire the other end to the modbus board terminals. CABLE CORE COLOUR RED BLACK MODBUS BOARD TERMINAL CN1-A CN1-B 5. Go to Section 15 SYSTEM CONFIGURATION to complete install. IMPORTANT: 1. The Standard Haier remote must be installed to provide temperature sensing. 2. MyZone functionality is not available for Haier units. Installation Guide V1.2 6

5 - DAIKIN ( DK) SETUP DK setup steps are as follows: 1. Connect the Daikin wired remote to the indoor unit in the roof space. 2. Power up the air conditioner & run the unit to test correct operation of indoor & outdoor unit. 3. Using the Daikin wired remote change the field settings for use with either the Return Air Sensor or a MyZone Sensor (if supplied) Return Air Sensor Menu Setting Value 20 2 02 22 6 01 MyZone Sensor Menu Setting Value 20 2 03 22 6 01 How to set Daikin field settings: a. Press and hold the CANCEL Button (bottom right corner button) b. Select Field setting list and press MENU/ENTER (middle round button) c. Use the UP / DOWN buttons to select the Menu number. d. Press the LEFT / RIGHT buttons to select the Setting. e. Press the UP / DOWN buttons to change the Value. f. Press MENU / ENTER button (middle round button) to save this setting. g. Select YES to the question Is it settled by setting? h. Repeat for any other required field settings. 4. Power off the Daikin air conditioner & remove Daikin wired remote control from system. 5. Connect the supplied cable from the CB to the indoor unit. Wire the cable cores to the terminals as shown below: CABLE CORE COLOUR RED BLACK INDOOR UNIT TERMINAL P1 P2 6. Go to Section 15 SYSTEM CONFIGURATION to complete install. Installation Guide V1.2 7

6 - FUJITSU ( FJ) SETUP FJ setup steps are as follows: Optional: Connect a Fujitsu remote control and check unit works, before installing MyAir controls. 1. Ensure power to the air conditioner is off & the Fujitsu wired remote control is not connected to the system. 2. Connect the supplied cable from the CB to the indoor unit. Wire the cable cores to the terminals as shown below: CABLE CORE COLOUR RED WHITE BLACK INDOOR UNIT TERMINAL 1 (RED) 2 (WHITE) 3 (BLACK) 3. Go to Section 15 SYSTEM CONFIGURATION to complete install Note: If Auto Field Settings are disabled on the CB (see section 12) then the field settings will need to be set manually from a Fujitsu remote, to the values shown below. Return Air Sensor Function Number Setting Value 42 00 48 00 MyZone Sensor Function Number Setting Value 42 01 48 01 7 - LG ( LG) SETUP LG setup steps are as follows: Optional: Connect a LG remote control and check unit function, before installing MyAir controls. 1. Ensure power to the air conditioner & controls is off. 2. Remove the LG wired remote controller and connect the supplied cable from the CB to the connector for the remote. 3. Go to Section 15 SYSTEM CONFIGURATION to complete install Installation Guide V1.2 8

8 - MITSUBISHI ELECTRIC ( ME) SETUP ME setup steps are as follows: Optional: Connect a Mitsubishi remote control and check the unit works, before installing MyAir controls. 1. Ensure power to the air conditioner & controls is off. 2. Check that the Mitsubishi Electric wired remote control is not connected to the system. 3. Connect the supplied cable from the CB to the indoor unit. Wire the cable cores to the terminals as shown below: CABLE CORE COLOUR INDOOR UNIT TERMINAL RED 1 BLACK 2 4. Go to Section 15 SYSTEM CONFIGURATION to complete install 9 - SAMSUNG ( BDSAM) SETUP BDSAM setup steps are as follows: 1. Connect the Samsung wired remote (MWR-WE10N) to the indoor unit in the roof space. IMPORTANT: This is a required step, the unit will not run without first connecting the Samsung remote. 2. Run the unit & test correct operation of indoor & outdoor unit. 3. Connect the supplied cable from the CB to the indoor unit. Wire the cable cores to the terminals as shown below: CABLE CORE COLOUR RED BLACK INDOOR UNIT TERMINAL F3 F4 4. Go to Section 15 SYSTEM CONFIGURATION to complete install Installation Guide V1.2 9

10 - PANASONIC ( PA) SETUP PA setup steps are as follows: 1. Connect the Panasonic wired remote to the indoor unit in the roof space. 2. Using the Panasonic wired remote change the field settings for use with either the Return Air Sensor or a MyZone Sensor (if supplied) Return Air Sensor Menu Setting Value 1 0A 0000 1 01 0001 Panasonic Remote CZ-RTC2 MyZone Sensor Menu Setting Value 1 0A 0001 1 01 0001 Return Air Sensor Menu Setting Value 1 01 0001 2 32 0000 Panasonic Remote CZ-RTC4 MyZone Sensor Menu Setting Value 1 01 0001 2 32 0001 2 32 0000 2 32 0001 How to set Panasonic field settings for Menu s 1 & 2: Menu 1 a. Press and hold the MODE (Top Right) & TIMER SET buttons together for 5 seconds. b. Use UP & DOWN TEMPERATURE buttons to change the 1st value c. Use UP & DOWN TIMER buttons to change the 2nd value d. When you are done press the SET button e. Repeat from step b to set second required code f. Press the SPANNER button to return to main screen Menu 2 a. Press and hold the SPANNER, SET & CANCEL buttons together for 5 seconds. b. Use UP & DOWN TEMPERATURE buttons to change the 1st value c. Use UP & DOWN TIMER buttons to change the 2nd value d. When you are done press the SET button e. Press the SPANNER button to return to main screen 3. Power off the Panasonic air conditioner & remove Panasonic wired remote control from system. 4. Connect the supplied cable from the CB to the indoor unit. Wire the cable cores to the terminals as shown below: CABLE CORE COLOUR RED INDOOR UNIT TERMINAL R1 BLACK R2 5. Go to Section 15 SYSTEM CONFIGURATION to complete install Installation Guide V1.2 10

11 - TOSHIBA ( TO) SETUP TO setup steps are as follows: 1. Connect the Toshiba wired remote to the indoor unit in the roof space. 2. Power up the air conditioner & run the unit to test correct operation of indoor & outdoor unit. 3. Using the Toshiba wired remote change the field settings (DN code) for use with either the Return Air Sensor or a MyZone Sensor (if supplied) Return Air Sensor DN Code Value 32 0000 05 0009 MyZone Sensor DN Code Value 32 0001 05 0009 How to set Toshiba field settings: a. Push the MENU button to display the menu screen. b. Push & hold the MENU + DOWN buttons at the same time for 4 seconds to open the field settings menu. c. Use the DOWN arrow to select option 5, DN CODES d. Press F2 then use UP / DOWN arrow to navigate to the required DN code e. Press F2 to move right & highlight DATA value f. Use UP/DOWN arrow to set required value g. Use the MENU button to fix (store) the setting & press F1 to confirm h. Press the RETURN button to go back to the field settings menu, you will see an hour glass for approx. 30 seconds. i. Press RETURN twice more to go back to main screen j. Repeat all the steps for each required setting 4. Power off the Toshiba air conditioner & remove Toshiba wired remote control from system. 5. Connect the supplied cable from the CB to the indoor unit. Wire the cable cores to the terminals as shown below: CABLE CORE COLOUR RED BLACK INDOOR UNIT TERMINAL A B 6. Go to Section 15 SYSTEM CONFIGURATION to complete install Installation Guide V1.2 11

12 - HITACHI ( HIT) SETUP HIT setup steps are as follows: 1. Connect the Hitachi wired remote to the indoor unit in the roof space. 2. Power up the air conditioner & run the unit to test correct operation of indoor & outdoor unit. 3. Using the Hitachi wired remote change the field settings for use with either the Return Air Sensor or a MyZone Sensor (if supplied.) OPERATION MODE RETURN AIR SENSOR MYZONE SENSOR THERMISTOR SELECTION I.U Thermistor THM of RCSW How to set Hitachi field settings: a. Press and hold the Return button ( ) and the Menu button ( ) simultaneously for more than 3 seconds to enter settings mode. Settings mode can only be entered when the AC unit is not running. b. Scroll down to the Function Selection option using the Down arrow ( ) and press the OK button. c. Scroll down to Item C5 using the Down arrow ( ). Check the value 00 is set. If not 00, scroll left or right using the arrow ( ) buttons unit 00 is shown and press the OK button. Select YES to the question when prompted Confirm function selection setting? and press the OK button to save the setting. d. Scroll down to the Thermistor Selection option using the Down arrow ( ) and then press the OK button. e. Press the left or right arrow ( ) to scroll to select the correct option outlined in step #3 above. f. Press the OK button to enter the new selection. g. Select YES using the left arrow ( ) to the question when prompted Confirm setting of thermistor selection? h. Press the OK button to save this setting. i. Press the Return button ( ) to exit from settings mode. 4. Power off the Hitachi air conditioner & remove Hitachi wired remote control from system. Continues over page... Installation Guide V1.2 12

13 - HITACHI ( HIT) SETUP 5. Connect the supplied cable from the CB to the indoor unit. Wire the cable cores to the terminals as shown below: CABLE CORE COLOUR RED BLACK INDOOR UNIT TERMINAL A B 6. Go to Section 15 SYSTEM CONFIGURATION to complete install 14 - MITSUBISHI HEAVY IND. ( MHI) MHI setup steps are as follows: 1. Ensure power to the air conditioner is off & you have not connected the Mitsubishi Heavy Industries wired remote to the air conditioner indoor unit. 2. Connect the supplied cable from the CB to the indoor unit. Wire the cable cores to the terminals as shown below: CABLE CORE COLOUR RED BLACK INDOOR UNIT TERMINAL X Y 3. Go to Section 15 SYSTEM CONFIGURATION to complete install Installation Guide V1.2 13

15 - SYSTEM CONFIGURATION Now the (and variants) have been paired to the indoor unit. The following steps will complete the system configuration. IMPORTANT: Due to heat transfer in summer, the CB should be installed at least 1m away from roofing materials, such as roof tiles. 1. Connect the zone motors, touch screen and antenna NOTE: Antenna only supplied when wireless temperature sensors are ordered IMPORTANT: Keep control cables, such as the TSP cable and the indoor unit link cable, away from other 240V cables or devices. 2. Check System ID, the System ID dipswitch is found on the CB. If there are multiple systems in one install then the System ID for each CB must be set to a different switch combination. The System ID may also need to be changed if a clash occurs with nearby installations. 3. Check the Settings dipswitch: Switch no. 2 must be in the ON position, Switch no. 5 must be ON to use the Return Air Sensor OR in the OFF position to use a MyZone Sensor. System ID Dipswitch Settings Dipswitch NOTE: For Fujitsu units only, Auto Field Settings are disabled when switch no. 10 is in the ON position. 4. Plug power supply into control box. IMPORTANT: The power transformer () must be plugged into a surge protected power outlet/point. 5. Configure a sensor for each zone. Wireless a. Set the System ID on each sensor to match your control box. b. Set the zone number by flicking the appropriate switch on (eg if you would like to set a sensor as zone 6 you would flick only switch 6 ON.) Wired Set the zone number by flicking the appropriate switch on (eg if you would like to set a sensor as zone 6 you would flick only switch 6 ON.) Continues over page... Installation Guide V1.2 14

16 - SYSTEM CONFIGURATION 6. Power up the air conditioning system. 7. Open the MyPlace app on the home page of the wall mounted touch screen 8. Press the SETUP button 9. Press the TECH SETUP button. 10. Enter password 22369 to access the setup. 11. Press Run Wizard, and follow the prompts on the screen. 12. When you have completed the setup wizard press ADVANCED to see additional options below. SET ACTIVATION CODE (Optional 21-day activation feature) By setting a 4-digit activation (lock-out) code the air con system will stop working after 21 days, it is STRONGLY recommended that your company always uses the same 4-digit pin code, and that everyone in your company knows this number. If the pin code to a system is forgotten, the control box requires replacing to activate the system. BALANCE ZONES This is where you can balance your zones if needed. For example: if zone 6 has too much air flow we could set MAX 80% this would result in the motor never driving past the 80% open position, the customer will not see these changes on the zone screen. TEMPERATURE SENSORS This screen allows you to check each sensor is operating correctly, each zone will display one of the below: Multiple sensors on this zone - Two or more sensors are configured to the same zone or you may be picking up a neighbour s system in which case you would need to change the System ID, via the System ID dipswitch in the CB. Battery Low - Check that the antenna is fitted to the CB, ensure there is a battery fitted within the sensor & the sensor is within range. Sensor OK - Check that all sensors show OK before proceeding. SENSOR NOT DISPLAYED: No sensor set for this zone, it will be % control only. If you have a sensor in this zone check the battery strip is removed, check battery inserted correctly. Check System ID is correct & check that only one sensor is configured for each zone. Installation Guide V1.2 15

MyAir+ Installation Guide Contents 1 - SYSTEM OVERVIEW 2 - MASTER / SLAVE CB 3 - HOME SCREEN 14 15 16 Installation Guide V1.2 17

Master Entry Favourites WIR Groups Scenes Ensuite SetUp Help Hall Way Rocco Jade Bathroom Guest Kitchen Dining Living CM / SAM OTHER CM / SAM OTHER CM / SAM OTHER 1 - SYSTEM OVERVIEW Slave CB s EXT MY+ TOUCH SCREEN Master Favourites Master CB Indoor Unit OR CM / SAM OTHER EXT MY+ TOUCH SCREEN EXT MY+ 10x RF Wall Sensors (if installed) [RFWS] 10x Zone Motors [CLIP24] EXT TOUCH MY+ SCREEN CB EXT MY+ EXT 8 MyLights LM (if installed) Wired Wall Sensor (if installed) TOUCH SCREEN Slave CB s cannot be connected to Mylights & Do not have a TSP All other setup can be the same as the Master (ie. Up to 10 RFWS & 10 Zone Motors per CB) EXT MY+ MyAir+ allows for an installation to include up to 4 Air Conditioner (AC) units all controlled from the same TSP (touchscreen.) Installation Guide V1.2 18

Master Favourites Master Entry Favourites WIR Groups Scenes Ensuite SetUp Help Hall Way Rocco Jade Bathroom Guest Kitchen Dining Living Master Entry CM / SAM OTHER Favourites WIR Groups Scenes Ensuite SetUp Help Hall Way Rocco Jade Bathroom Guest Kitchen Dining Living CM / SAM OTHER CM / SAM OTHER CM / SAM OTHER 2 - MASTER / SLAVE CB There can only be one TSP connected per system. The Master is the CB that is connected to the TSP. NOTE: If MyLights is to be installed the LM s need to connect to the Master CB and not a Slave CB. If only one slave CB is required then the slave may be connected directly to the master as shown. Master Favourites Master CB CM / SAM OTHER EXT TOUCH MY+ SCREEN Slave CB TOUCH SCREEN EXT MY+ In cases where there is more than one Slave a EXT MY+ module must be used as shown below. Slave CB s EXT MY+ TOUCH SCREEN Master CB CM / SAM OTHER EXT MY+ TOUCH SCREEN EXT MY+ EXT TOUCH MY+ SCREEN EXT MY+ TOUCH SCREEN EXT MY+ Installation Guide V1.2 19

3 - HOME SCREEN Once the MyPlace app has been run the MyAir+ tab will display the home screen as shown above. Each icon set represents a single Air Conditioner, pressing in the top left area of the icon will open that Air Conditioning unit. Each AC unit operates as a MyAir system and can be setup as per the MyAir section of this manual. 4 - WIRING The cable length between the CB s and the MY+ EXT should be as follows: CB LENGTH OF CABLE (CB to MY+ EXT) MASTER 0.5m SLAVE 12m or 25m Installation Guide V1.2 20