Embedded I/O Expansion Board with 10 Outputs

Similar documents
ArmorPoint I/O Field Potential Distributor, Series A

CompactLogix Power Supplies Specifications

DeviceNet ArmorBlock Network and Auxiliary Powered I/O Module

DeviceNet ArmorBlock Network and Auxiliary Powered Module, Series A

DeviceNet ArmorBlock Network Powered 16-input Module, Series A

DeviceNet ArmorBlock Network Powered 16-input Module

ArmorPoint 24V dc Input Modules, Series A

EH-RIO IP67 Profibus-DP I/O modules

USB-to-DeviceNet Cable

16 Input/16 Output Digital Embedded I/O Boards

CompactBlock Guard I/O EtherNet/IP Safety Modules

Digital ac/dc (24V) Input Module

PROFIBUS 1732 ArmorBlock I/O, Series A

Installation Instructions. FLEX I/O D-Shell Terminal Base Units and Distribution Boards

1756 ControlLogix Chassis Specifications

ArmorBlock Guard I/O DeviceNet Safety Modules

ControlNet-to-DeviceNet Linking Device

Isolated 24V dc Output Module

PCI Expansion Slot Kit for 6181P (1500P) Series D Integrated Display Computer

1756 ControlLogix Chassis Specifications

ArmorBlock 2-Port EtherNet/IP Module

POINT I/O PROFIBUS Adapter

ArmorPoint 24V dc Analog Input Modules, Series A

InView Firmware Update

About the PCMK/B Card

Installation Instructions

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

ArmorPoint 4-Channel 24V dc Analog Input Module, Series A

Installation Instructions

ArmorPOINT I/O 5V DC Encoder/Counter Module, Series A

Allen-Bradley 1786-RPFRXL

VersaView Industrial Non-display Computers

PanelView 600 Terminals

Micro800 Programmable Controller Family. Bulletin 2080 Selection Guide

Kinetix 6000 Axis Module and Shunt Module

Digital ac/dc (24V) Input Module

GuardPLC Digital Input/Output Module

Differential Liquid/Gas Pressure Transmitter

Solar Combiner Enclosure

Micro800 Programmable Controller Family. Bulletin 2080 Selection Guide

ArmorBlock 16-Point EtherNet/IP Module

1732E ArmorBlock Dual-Port EtherNet/IP 4-Point Thermocouple and RTD Input Modules

Installation Instructions

POINT I/O 24V DC 4-channel Discrete Input Module with Diagnostics

16 Input/16 Output Digital and 2 Input/2 Output Analog Embedded I/O Boards

XM Monitoring Modules Specifications

SLC 500 System Overview

InView Communication Modules

GuardPLC 1600 Controllers

SLC 500 System Overview

Kinetix 300 Memory Module Programmer

Teaching Color-Sensing Connected Components Building Block. Quick Start

Environmental Specifications CompactLogix Controllers and Compact GuardLogix 5370 Controllers

Installation Instructions

Color-Sensing Connected Components Building Block. Quick Start

Stratix 5700 Ethernet Managed Switches

Integrated Display Computers

VIBRATION MONITOR CX-RLY

PCI 2 Axis Servo Card

Compact Industrial Non-display Computers

Output Voltage* (nom.)(adjustable)

PanelView Plus/VersaView CE Terminals and Display Modules

CompactLogix Controllers Specifications

SLC 500 System Overview

Stratix Ethernet Device Specifications

PCI 2 Axis Servo Card

MicroLogix 1762-IQ16 DC Input Module

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Output Voltage* (nom.)(adjustable)

llen-bradley 2080-LC30-16QVB

MINI-PS AC/10-15DC/8

Installation Instructions

User Manual Digital Input Module

TU531, TU532 Terminal Unit

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

DriveGuard. Safe-Off Option for PowerFlex 70 AC Drives. User Manual.

TRIO-DIODE/12-24DC/2X10/1X20

PanelView Component HMI Terminals

Select a Micro800 Controller

Electronic timer CT-ERD.12

TF501, TF521 Terminal Bases

PowerMonitor 1000 Unit Catalog Number Upgrade

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Electronic timer CT-AHD.22

ControlLogix SIL2 System Configuration

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Redundancy unit CP-A RU

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Simple Package Measurement Connected Components Building Block. Quick Start

GuardLogix: Dual Zone Gate Protection with E-stop and Trojan Interlock Switch

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

ProcessLogix R510.0 Server Installation Instructions

Electronic timer CT-ERS.21

Transcription:

Installation Instructions Embedded I/O Expansion Board with 10 Outputs Catalog Number 1799-OQ10X Topic Page Important User Information 2 Environment and Enclosure 3 About the Board 4 Install the Board 6 Mount the Board 6 Connect the Board 8 Interpret the Status Indicators 11 Specifications 13

2 Embedded I/O Expansion Board with 10 Outputs Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://literature.rockwellautomation.com) describes some important differences between solid state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Throughout this manual, when necessary, we use notes to make you aware of safety considerations. WARNING IMPORTANT ATTENTION Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. Identifies information that is critical for successful application and understanding of the product. Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard and recognize the consequences. SHOCK HAZARD Labels may be on or inside the equipment (for example, drive or motor) to alert people that dangerous voltage may be present. BURN HAZARD Labels may be on or inside the equipment (for example, drive or motor) to alert people that surfaces may reach dangerous temperatures.

Environment and Enclosure Embedded I/O Expansion Board with 10 Outputs 3 ATTENTION This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in IEC 60664-1), at altitudes up to 2000 m (6562 ft) without derating. This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR 11. Without appropriate precautions, there may be difficulties with electromagnetic compatibility in residential and other environments due to conducted and radiated disturbances. This equipment is supplied as open-type equipment. It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts. The enclosure must have suitable flame-retardant properties to prevent or minimize the spread of flame, complying with a flame spread rating of 5VA, V2, V1, V0 (or equivalent) if non-metallic. The interior of the enclosure must be accessible only by the use of a tool. Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings that are required to comply with certain product safety certifications. In addition to this publication, see: Industrial Automation Wiring and Grounding Guidelines, Rockwell Automation publication 1770-4.1., for additional installation requirements. NEMA Standard 250 and IEC 60529, as applicable, for explanations of the degrees of protection provided by different types of enclosure.

4 Embedded I/O Expansion Board with 10 Outputs ATTENTION Preventing Electrostatic Discharge This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when you handle this equipment: Touch a grounded object to discharge potential static. Wear an approved grounding wriststrap. Do not touch connectors or pins on component boards. Do not touch circuit components inside the equipment. Use a static-safe workstation, if available. Store the equipment in appropriate static-safe packaging when not in use. ATTENTION Do not wire more than 2 conductors on any single terminal. ATTENTION To comply with the CE Low Voltage Directive (LVD), this equipment and all connected I/O must be powered from a source compliant with the following: Safety Extra Low Voltage (SELV) or Protected Extra Low Voltage (PELV). ATTENTION To comply with UL restrictions, this equipment and all connected I/O must be powered from a source compliant with the following: 10 30V DC Class 2 Power Supply or a 10 30V DC UL Listed or Recognized Power Supply with isolated outputs limited to 200 volt-amperes in each ungrounded output line. This equipment and its power source must be mounted in a suitable enclosure with proper spacings maintained. About the Board The 1799-OQ10X is an expansion 10-point Output board that works only with 1799ER-IQ10XOQ10 as an expansion I/O module. This board has 10 outputs, that are self-protected 24V DC sinking or sourcing.

Embedded I/O Expansion Board with 10 Outputs 5 45076 Parts List Your package contains: one 1799-OQ10X board. ribbon expansion cable four stand-off rods four countersunk screws four roundhead screws these installation instructions. Required Hardware All mating connectors must be ordered separately. This table identifies the different connector and hardware options. Option Catalog Number Third-party Supplier & Part Number 2, 12-position, gold-plated I/O mating connectors 1799-12SPCON Phoenix - FK-MC 0.5/12-ST-2.5AU - 1923432 2-position plug for auxiliary power 1799-AUXCON Phoenix Contact, Part number MSTB2.5/2-ST-5.08 BK/AU - 1765551)

6 Embedded I/O Expansion Board with 10 Outputs Install the Board To install the board: mount the board (on 1799ER-IQ10XOQ10). connect the board (Auxiliary Power, I/O, ribbon expansion cable). More detailed information about each of these steps is in the following procedures. Mount the Board You can mount the board to the main board, 1799ER-IQ10XOQ10 using stand-off rods. 1. Place the four stand-offs onto the mounting screws and tighten them. 2. Place the screws through the expansion board into the stand-offs and tighten them.

Embedded I/O Expansion Board with 10 Outputs 7 DIN Rail or DIN Rail Bracket or 20 mm Stand-off 18 mm Mounting Plate 45074 3. Connect the expansion board to the base board with the ribbon expansion cable. IMPORTANT With the addition of the expansion board, the depth of the pair of boards is approximately 45 mm ( 1.77 in.).

8 Embedded I/O Expansion Board with 10 Outputs Board Dimensions 67.1 mm ( 2.64 in ) 19.1 mm ( 0.75 in ) 11.4 mm ( 0.45 in ) 87.6 mm ( 3.45 in ) 149.9 mm ( 5.90 in ) 11.4 mm ( 0.45 in ) 44999 Connect the Board Use these illustrations and tables to help you connect the board. Output Connector (P2) Aux Power (P3 ) Expansion Board Connector (P1) 45076

Embedded I/O Expansion Board with 10 Outputs 9 These tables identifies the signal for the connectors on the 1799-OQ10X. P3 Auxiliary Power Connector Pin Signal 1 24V DC 2 24V DC Ret P2 Output Connector Pin Signal 1 Output 0 2 Output 1 3 Output 2 4 24V DC Ret 5 Output 3 6 Output 4 7 Output 5 8 Output 6 9 24V DC 10 Output 7 11 Output 8 12 Output 9 Connect the Field Output Device to the I/O Connector (P3) The 1799-OQ10X board has outputs that supply current to your field output device (sourcing outputs) or sink current from your field output device (sinking outputs). Use these wiring diagrams to connect the outputs on this board.

10 Embedded I/O Expansion Board with 10 Outputs Outputs Outputs (Sourcing) 0 1 2 24V dc 3 4 5 6 24V dc 7 8 9 Return Load Outputs (Sinking) 0 1 2 24V dc 3 4 5 6 24V dc 7 8 9 Return Load 45081 Each output can be configured via a dip switch for sinking or sourcing output. Wire each output in accordance with your selected configuration. Default dip switch settings are at sinking output. Configure the switches before power-up. 10 9 8 7 6 5 4 3 2 1 OUT SINK O N OUT SOURCE 45073

Embedded I/O Expansion Board with 10 Outputs 11 Interpret the Status Indicators This board has the following status indicators. Power (1) Individual output (10) Auxiliary Status Indicator I/0 Status Indicators 45075 Indicator Status Auxiliary status Output status Status Off Green Off Yellow Description No auxiliary power to device or input not valid. Auxiliary power applied to device. Output not energized. Output energized.

12 Embedded I/O Expansion Board with 10 Outputs Communicate with Your Module 1799-OQ10X + 1799-OQ10X Data Definition (optional) Instance 161 - Consumed 20 Point Output Consumed Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 0 Out7 Out6 Out5 Out4 Out3 Out2 Out1 Out0 1 Out15 Out14 Out13 Out12 Out11 Out10 Out9 Out8 2 Reserved Out19 Out18 Out17 Out16 3 Reserved EtherNet/IP Connection with RSLogix 5000 The following instructions are for RSLogix 5000 version 17 or later. 1. Power down and connect the expansion board to base board. 2. Power up the board and obtain the IP address via DHCP. 3. In the General tab, click the Change button. 4. In the Module Definition screen, select 1799-OQ10X 10 Point 24V DC output for the expansion module. 5. Click the OK button, then click the Apply button.

Embedded I/O Expansion Board with 10 Outputs 13 Specifications Output Attribute Outputs per block Output auxiliary voltage On-state voltage drop On-state current Off-state leakage Card current (all outputs on) Surge current - for 10ms, repeatable Every 2 s (individual outputs) Value 10 sinking or sourcing, 0.5A, short circuit protected, pilot duty 10...30V DC 250 mv max 0.5 A max 20 μa max 4.0 A max 1.0 A General Attribute Auxiliary power voltage range Auxiliary power current outputs on Auxiliary power current outputs off Voltage rating Dimensions (H x W x D), approx. Weight, approx. Enclosure type rating Pilot duty rating Isolation voltage Value 24V DC nominal (10...30V DC) 4 A max 36 ma Vi = 24V DC, Ii = 4A, Vout = 30V DC, Iout = 0.5A, Isurge=1A 67.1 x 149.9 x 18 mm (2.64 x 5.97 x 0.71 in.) 0.10 kg (0.22 lb) None (open-style) NEMA DC-14 50V (continuous), Basic Insulation Type, Outputs to System No isolation between individual Outputs, and Outputs to I/O (Aux) Power Type tested at 750V DC for 60 s.

14 Embedded I/O Expansion Board with 10 Outputs General Attribute Power dissipation I/O and auxiliary power wire size Wiring category (1) Value 1.12W @ 30V DC Auxiliary Power In I/O: 0.13...0.5 mm² (26...20 AWG) solid or stranded copper wire rated at 75 oc (167 F) or greater. 1.2 mm (3/64 in.) insulation max. Auxiliary power: 0.80...2.5 mm² (18...14 AWG) solid or stranded copper wire rated at 75 oc (167 F) or greater. 1.2 mm (3/64 in.) insulation max. 2 - on signal ports 2 - on power ports (1) Use this Conductor Category information for planning conductor routing. Refer to publication 1770-4.1, Industrial Automation Wiring and Grounding Guidelines. Environmental Specifications Attribute Temperature, operating Temperature, storage Relative humidity Vibration Shock, operating Shock, non-operating Value IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, Operating Dry Heat), IEC 60068-2-14 (Test Nb, Operating Thermal Shock): -20 70 C (-4 158 F) IEC 60068-2-1 (Test Ab, Unpackaged Non-operating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Non-operating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Non-operating Thermal Shock): -40 85 C (-40 185 F) IEC 60068-2-30 (Test Db, Unpackaged Damp Heat): 5 95% non-condensing IEC60068-2-6 (Test Fc, Operating): 2 g @ 10 500 Hz Emissions CISPR 11: Group 1, Class A IEC60068-2-27 (Test Ea, Unpackaged Shock): 30 g IEC60068-2-27 (Test Ea, Unpackaged Shock): 50 g

Environmental Specifications Attribute ESD immunity IEC 61000-4-2: 6 kv contact discharges 8 kv air discharges Radiated RF immunity Embedded I/O Expansion Board with 10 Outputs 15 IEC 61000-4-3: 10V/m with 1 khz sine-wave 80% AM from 80 2000 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz 10V/m with 1 khz sine-wave 80% AM from 2000 2700 MHz EFT/B immunity IEC 61000-4-4: ±2 kv at 5 khz on power ports ±2 kv at 5 khz on signal ports Surge transient immunity Conducted RF immunity Value IEC 61000-4-5: ±1 kv line-line(dm) and ±2 kv line-earth(cm) on power ports ±1 kv line-line(dm) and ±2 kv line-earth(cm) on signal ports IEC 61000-4-6: 10V rms with 1 khz sine-wave 80% AM from 150 khz 80 MHz Certifications (when product is marked) (1) Attribute c-ur-us CE C-Tick Value UL Recognized Component Industrial Control Equipment, certified for US and Canada. See UL File E322657. European Union 2004/108/EC EMC Directive, compliant with: EN 61326-1; Meas./Control/Lab., Industrial Requirements EN 61000-6-2; Industrial Immunity EN 61000-6-4; Industrial Emissions EN 61131-2; Programmable Controllers (Clause 8, Zone A & B) Australian Radiocommunications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions (1) See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.

Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products. At http://support.rockwellautomation.com, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools. For an additional level of technical phone support for installation, configuration, and troubleshooting, we offer TechConnect support programs. For more information, contact your local distributor or Rockwell Automation representative, or visit http://support.rockwellautomation.com. Installation Assistance If you experience a problem within the first 24 hours of installation, please review the information that's contained in this manual. You can also contact a special Customer Support number for initial help in getting your product up and running. United States 1.440.646.3434 Monday Friday, 8 a.m. 5 p.m. EST Outside United States Please contact your local Rockwell Automation representative for any technical support issues. New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility. However, if your product is not functioning and needs to be returned, follow these procedures. United States Outside United States Contact your distributor. You must provide a Customer Support case number (see phone number above to obtain one) to your distributor in order to complete the return process. Please contact your local Rockwell Automation representative for the return procedure. Allen-Bradley, TechConnect, RSLogix 5000, and Rockwell Automation are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. PN-204014 Supersedes Publication 1799-IN013A-EN-P - March 2010 Copyright 2013 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.