DL700 Operator Manual

Similar documents
USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

An ISO-9001 Certified Company

SAVI Wireless Mobile Cardiac Telemetry

Cadwell Easy Ambulatory Setup, Startup and Shutdown Guide

USER MANUAL. TS Series (Model 52X) Terminal Strip Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

VELOCICALC Air Velocity Meter

User Guide. Moisture Meter. Model MO250

CardioPAL SAVI Personal Arrhythmia Logger

BMS 300 Digital Holter Recorder User Manual

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8

IGLOO IGLOO EASY INSTRUCTION MANUAL

User s Manual. Digital Baby Scales. Hopkins Featherweight Baby Scale # Hopkins Featherweight XL Baby Scale # # #688340

D-Pack 6 Classic ORDERCODE 50315

Integrating Sound Level Datalogger Model

Elapsed Timer Control Panel

DCS200/DCS200-09/DCS DCS300/DCS300-09/DCS355

Audio. one CAT-5 EXT-DVI-1CAT5-SR. User Manual. Release A2

IGLOO IGLOO EASY INSTRUCTION MANUAL

USER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem

WA4204-G2/G3 and WA4304-G2/G3

Pulse LED Instruction Guide

OWNER S MANUAL Calc-U-Dri PRINTER

INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE

RV LEVELING SYSTEM AUTO LEVEL SYSTEM WARNING! FAILURE TO ACT IN ACCORDANCE WITH THE FOLLOWING MAY RESULT IN SERIOUS PERSONAL INJURY OR DEATH.

4-20mA Display. Installation and Operation Manual. Rev 4/3/2019 Part #

User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

Installation Instructions

ATMOX Power Supply ATMOX AC Adapter with Plugs. Wiring Guide

Model P4470 Save A Watt Operation Manual

POCKET MULTIMETER Model No: MM18

3.5 TFT LCD CCTV Service Viewer with Wristband LCD35SV

CerePlex A. Instructions for Use. 630 Komas Drive Suite 200. Salt Lake City UT USA P F

Residential/Light Commercial Remote Control System

24/7 Sprinkler Monitor. The Ultimate Rain/Freeze Sensor

Users Manual OPN Pocket Memory Scanner

HDMI to 3GSDI Converter

Model EZ3400 EasyTouch Owner s Manual

Video Borescope Inspection Camera

1 Channel Strobe Controller ORDERCODE 40226

Installation Instructions

Component identification

Instruction Guide. Removable Drive Drawer for 3.5 SCSI 320 Hard Drives DRW150SCSI DRW150SCSIBK DRW150SCA DRW150SCABK

TM-SERIES TABLE MOUNTING BRACKETS USER S GUIDE

THE CTB08D LIGHT CONTOLLER

Instructions for Use and Technical Documentation

Progressive Industries, Inc. EMS Electrical Management System

OnePlus 5 Screen and Digitizer Assembly Replacement

MODE. Welch Allyn 767 SureTemp 4 Thermometer System. Directions For Use

User s Guide. connected

Agilent 16442B. User s Guide. Agilent Technologies

Antenna Distributor ORDERCODE D1444

Audio. one CAT-5 EXT-DVI-1CAT5-SR. User Manual. Release A2

Installing the NEMA 4X Hatch

Installation manual plugs and connectors with screw connection (16/32 A)

BRADYMARKER XC Plus Printer

Product Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23

SpO 2 Upgrade Instructions

User's Manual Digital ECG IQmark Document ID: PUB-110 Revision B

CHAPTER 2: USING MANAGER PREFERENCE. 2.1 Using Manager Mode Using CSAFE Console (back side) Access Layout...

Sound Analyser Real Time 1/1 & 1/3 Octave band Analysis

QuickTouch (QT4) Owner s Manual

DVI Detective. User Manual EXT-DVI-EDIDN. Release A3

COBEX RECORDERS, INC.

RING CUTTING SYSTEM OPERATION MANUAL

DreamStation Cellular Modem

VK-3iX WARRANTY REGISTRATION FORM

Title: Electrocardiogram (ECG)

SECURE/NONSECURE LED SIGN USER MANUAL

Motorola Moto Z2 Play Audio Jack Replacement

INSTALLATION AND USER GUIDE 2800LBY SINGLE LINE HOTEL LOBBY TELEPHONE

Net-Ritef Continuity and Wiremap Tester Trace-Ritef Tone Generator and Amplified Tone Tracer User's Guide.

DVI ELR Extender over one CAT5

P4472 Save A Watt HD Operation Manual

Large Police Light 100W ORDERCODE 80361

K Service Source. Color StyleWriter 2200

Power TracKer VII. User s Manual 2006 AVID. Multi Mode Reader. Manufactured under one or more of the following Patents:

Customer Replacement Procedure

DVI ELR Extender over one CAT5

STANDARD OPERATING PROCEDURE TONOPORT V

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

MTX-A Temperature Gauge User Manual

Instruction Manual. RainLog /10/13. Rev.0

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

True RMS AC Voltage/Current Datalogger

User s Manual Power Supply IM E. 5th Edition

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

User's Manual Sound Level Alert Model SL130

PIXIM Micro Dome Camera

SATA II HDD Canister KISS DA 435 Quick Reference Guide

Rev. A. ANC Series RS-485/RS-422 Synchronous Clock Display. Antona Corporation (818) URL:

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A

ENGLISH Flexstrip Set IP44 RGB

User's Guide. Phase Sequence and Motor Rotation Tester Model

PLR BP1. Proloop Body Pack Induction Loop Receiver. Instructions For Use and Care

I/O Expansion Box Installation & Operator s Instruction Manual

M U L TI - SP ORT SCOREBOARD

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

Removing and Replacing Parts

3M Indoor Protected Building Entrance Terminal 4788V-QCS Series

Transcription:

Braemar, Inc. DL700 Operator Manual Caution: U.S. Federal law restricts this device to sale by or on the order of a physician.

Braemar Limited Warranty Braemar products are warranted to be free from manufacturing and material defects for a period of one (1) year from the date of shipment from Braemar to the original purchaser. Excluded from this warranty are expendable supply items including, but not limited to, electrodes, leadwires, patient cables and batteries. This warranty does not apply to any product that Braemar determines has been modified or damaged by the customer. Except for the express warranties stated above, Braemar disclaims all warranties including implied warranties of merchantability and fitness. The stated express warranties are in lieu of all obligations of liabilities on the part of Braemar for damages, including but not limited to, special indirect or consequential, arising out of or in connection with the use or performance of Braemar products. Any action for breach of warranty shall be commenced within one (1) year of said breach or be forever barred. Any repairs made to the product that are not covered by the warranty shall be billed to the customer. Document Number: 600-0573-00 Revision: G Date: March 2006 i ii

Table of Contents Product Overview... 1 1. Description... 2 2. Specifications... 5 Product Operation... 7 3. Recorder Preparation... 8 3.1 Battery Installation... 8 3.2 Setting the Clock... 8 4. Electrode Application... 10 4.1 Materials Needed... 10 4.2 Recommended Steps... 10 5. Operation... 12 5.1 Materials Needed... 12 5.2 To Start Recording... 12 5.3 To Stop Recording... 14 5.4 Analyzing the ECG Data... 14 Service And Maintenance... 15 6. Maintenance... 16 6.1 Replacing the Clock Battery... 16 7. Troubleshooting Guide... 18 7.1 Problem Description and Recommended Solution... 18 8. Service Items... 20 Appendix A... 21 9. Electrode Placement (7 Lead)... 22 10. Electrode Placement (5 Lead)... 24 iii iv

Product Overview 1. Description The DL700 Holter Recorder is a battery operated solid state recorder designed for 24 hour continuous recording of ambulatory ECG data. It is an AAMI Type I device, which is part of a conventional AECG monitoring system where the ECG is recorded on a removable Flash memory card in the DL700. After the ECG data has been recorded, the memory card is removed from the DL700 and inserted in a Flash Card Reader which is part of the Computer Analysis System on which the ECG will finally be analyzed. The Flash memory card used in the DL700 is the same as some PCMCIA memory cards used in laptop computers. Batteries and Receptacle The DL700 provides a battery compartment with secure receptacles for inserting two standard AA alkaline batteries. A polarity guard feature is built in to prevent damage in case the batteries are installed incorrectly. Cover Labeling The label on the outside of the cover provides information about the company supplying the recorder while the label on the inside of the cover provides Patient Hook-up and Recording Start/Stop instructional information. Digital Clock A digital LCD clock is mounted into the front panel to provide both time and date for patient convenience. Clock Battery The digital clock is powered by a Duracell silver oxide 392B, 1.5V battery or its equivalent. For instructions on battery replacement, refer to the Maintenance Section. Clock Set Controls The clock set controls are used to set the date and time. Time can be set in hours and minutes. 1 2

Patient Event Button Patients should be instructed to use this Event Button anytime they feel symptoms similar to those which they have been instructed by their physician to note in their Patient Log along with date and time information. Gain Switch A gain switch is provided to allow the medical technician to adjust signal amplitude. Three positions are provided: 1/2X, 1X, and 2X. Position indications are on the label above the switch. Operating LED This is the green LED just to the right of the gain switch (Fig 1). It provides current status information on the recorder (See Operation Section). Equipment Symbols Symbol Description Figure 1 DL700 Holter Recorder Patient Input Connector The patient input connector provides a snug and reliable connection for the patient electrode leads along with complete color-coding for each lead. Test Jacks Three test jacks are provided to verify that a good, reliable signal is being obtained on each ECG channel immediately after connecting the electrodes to the patient. This test should be done prior to allowing the patient to leave the clinic. 0086 SN REF Type B equipment. Consult manual. Complies with the Medical Device Directive of the European Union. Waste Electrical and Electronic Equipment (WEEE) It is the responsibility of the end user to dispose of this equipment at a designated collection point for recycling. Year of Manufacture Serial Number Not shown - DL700 is the catalogue number. European Representative: CEpartner4U BV Esdoornlaan 13 3951 DB Maarn. The Netherlands Tel: +31 (0) 6-516.536.26 3 4

2. Specifications Functional Channels : 3 Resolution : 8-bit Recording : Full disclosure Minimum Recording Time Storage Medium : 24 hours : Removable FLASH memory (Standard PCMCIA-ATA card) Download Interface : PCMCIA card interface Physical Dimensions : 6.00" x 3.50" x.95" Weight : 10 ounces with batteries Enclosure : Molded plastic Operating Position : Any orientation Operating Temperature : 0 C to 45 C Non-operating Temperature : -40 C to 60 C Operating Humidity : 10% to 90% (non-condensing) Electrical Gain Settings : 1/2X, 1X, and 2X Battery : Two AA Alkaline (disposable) Connector : 7 pin (3 diff + 1 com), single lead wires Test Jacks : 3 channels 5 6

Product Operation 3. Recorder Preparation 3.1 Battery Installation To ensure a full 24 hour recording it is essential to use new batteries before each patient recording. The recommended batteries for the DL700 Holter recorder are two AA alkaline batteries (IEC-LR6). When inserting the batteries, follow the Start Recording procedure in the Operation section while making sure to follow the polarity indication shown on the label in the battery compartment. - Note - There is a built-in polarity guard feature to protect against damage to the recorder but if the batteries are installed improperly, the unit WILL NOT RECORD and the LED WILL NOT BLINK. 3.2 Setting the Clock Time and Date on the digital clock can easily be set by the following procedure using the two small access holes labeled "set" and "select". The holes are located next to the Patient Event Button shown in Figure 1. a) Insert and press a pointed object into the top access hole, labeled "set", to start the setting process. b) Press the pointed object into the bottom access hole, labeled "select". The digital display alternately shows the time and date. c) Press the bottom access hole a second time to select MONTH. - Note - Pressing the bottom access hole repeatedly, cycles the digital clock through each selection - Month, Date, Hour, Minutes. d) To set the current month, press the top access hole repeatedly to obtain the desired month. e) Press the bottom access hole again to select DATE. 7 8

f) To set the current date, press the top access hole repeatedly to obtain the desired date. g) Press the bottom access hole to select the HOURS. h) Press the top access hole repeatedly to set the correct hour in A.M. or P.M. i) Press the bottom access hole to select MINUTES. j) Once again, press the top access hole repeatedly to set the correct number of minutes. k) Press the bottom access hole to display the correct time. - Note - If it is desired to have the Date and Time flash alternately - press the bottom access hole after completing the previous step. Then, press the lower access hole 5 times to set the colon flashing. 4. Electrode Application For safe and effective use, it is recommended that application of electrodes be handled by trained medical personnel. Proper preparation of the patient's skin is absolutely essential to obtaining a quality ECG recording. - Note - Without good skin preparation, both noise and artifact will frequently degrade the patient s ECG to the point of being unusable by the physician. 4.1 Materials Needed a) For 3 channel recording, use seven (7) Silver-Silver chloride disposable pre-jelled electrodes designed for 24 hour Holter monitoring. Do not use 12-lead ECG or Stress Test Electrodes. Use electrodes designed for longer term 24 hour monitoring. b) 4 X 4 Prep Pads c) Isopropyl alcohol 4.2 Recommended Steps a) Select the sites for electrode application. The electrodes must be applied over bone or cartilage. Refer to the Electrode Placement Chart sections in Appendix A. b) Wipe the skin in the electrode areas with an alcohol prep pad. c) After allowing the skin to dry thoroughly, locate the electrode placement sites by palpation. d) Dry shave body hair from the electrode sites. 9 10 e) Using a small square piece of an abrasive material (220 grit sandpaper or equivalent) and moderate pressure, abrade the skin at the electrode sites by making 3 or 4 crossing strokes. The strokes should cross at the chosen electrode site. Lightly brush the areas with a dry gauze pad to

remove any debris. f) Connect the color coded snap-on lead wires to the appropriate electrodes before applying the electrodes to the patient. g) Once the backing is removed from each electrode, place it firmly on the prepared skin surface site. h) In order to prevent the lead from tugging directly on the electrodes, create a strain relief by looping each lead wire and placing a strip of adhesive tape over the loop as well as on the electrode. 5. Operation 5.1 Materials Needed a) One Flash memory card with a storage capacity of 10 MB or larger. The card requires no special formatting prior to its first use. b) Two AA Alkaline (IEC-LR6) batteries. c) Patient Diary. d) Recorder, either 5 or 7 lead patient cable, pouch or carrying case, shoulder strap and belt. 5.2 To Start Recording a) Enter the patient s personal data on the Flash memory card label including the doctor's name, patient's name, and the date and start time of the test. (A Sharpie, fine point, erasable marking pen is recommended). This information should also be noted in the patient's diary and the patient should then be instructed on how to fill out this diary. - Note - Since the flash memory card is intended to be reused, the patient label on the back side of the card has been designed to be easily erased so that the next patient s data can be written in the same area. Insure use of an erasable marker. b) Insert the Flash memory card into the recorder. c) The electrodes and lead wires should be attached to the patient as specified in the previous section (Electrode Attachment). Once this has been done, the lead wires must next be connected to the recorder carefully following the color code above the input connector. d) Install two fresh alkaline AA batteries. - Caution - All previous ECG patient data on the Memory card will be erased immediately once the new batteries are inserted. 11 12

e) The green operating LED will start to blink at a steady rate to indicate normal operation. The LED will blink at this rate for up to 15 minutes allowing time to verify that the signal on each channel is acceptable. After this startup interval, the LED will begin blinking at a slower rate to indicate that ECG recording has begun. The final blink rate will vary somewhat depending on the storage capacity of the flash card and the patient signal characteristics. - Warning - If the LED is NOT BLINKING after the previous step, the unit is NOT RECORDING. This LED is the only indicator that the recorder is functioning properly and it should always be blinking whenever the unit is recording. If it is not, please see the Troubleshooting Guide section. f) To insure that a good quality patient hookup has been achieved, a test ECG output strip can be run on an ECG machine. To run a test strip, connect a standard Test Box to the 3 recorder test jacks shown in Figure 1. Insert the plugs from the ECG machine into the Test Box. Run a test output strip. Verify that there is an acceptable signal on each channel. It may be necessary to adjust the gain by using the recorder gain switch located next to the green LED shown in Figure 1. After selecting the final gain setting, disconnect the Test Box from the recorder. g) To abort the standard 15 minute startup interval once the preparation is complete and it is desired to start the ECG recording, hold the event pushbutton in until the LED stops blinking (usually about 5 seconds). Release the pushbutton and the LED will start blinking at a slower rate, as described in Step e) above. h) Close the top cover of the recorder, place the recorder in the pouch, and attach the recorder to the patient utilizing either the belt or the shoulder strap. Caution the patient to avoid getting the recorder wet and to NOT pull on the electrodes. 5.3 To Stop Recording a) To stop recording after 24 hours, or sooner if desired, remove the batteries completely. - Warning - DO NOT RE-INSERT BATTERIES after removal as this will erase the ECG data on the Flash memory card. b) Remove the Flash memory card and patient electrodes. If it is desirable to remove the leads from the patient input connector, then, due to their snugness of fit in this connector, it is suggested that the medical technician carefully grip these leads only at the base whenever removing them. NEVER pull on the wire itself as this can easily break the wire inside the insulation causing a noisy and intermittent ECG recording. 5.4 Analyzing the ECG Data a) Insert the Flash memory card into the Flash card reader of the Computer Analysis System on which the ECG analysis is to be performed. b) The Computer Analysis System must have special download software installed to transfer the ambulatory ECG data from the Flash memory card to the Analysis System. c) Once the data transfer is complete, the previous patient s name and any other information written on the Flash memory card s label should be removed and the ECG data should be erased. d) The Flash memory card is now free to be used for the next patient. i) If there is a need to stop the recorder after the recording session has begun, please refer to the following section To Stop Recording. 13 14

Service And Maintenance 6. Maintenance The DL700 Holter Recorder requires virtually no maintenance. Ensure that the battery contacts are clean and that the inside of the recorder is free of dust and dirt. The case and the pouch with belt and strap can be cleaned with a lint free towel moistened with mild soap and water. Do not use any strong solvents. Clean as often as desired. 6.1 Replacing the Clock Battery The digital clock uses one 1.5V silver oxide battery (Duracell 392B or its equivalent). The battery has approximately a two year life. The battery is accessed under the top cover. a) Open the top cover. Use a small jeweler's screwdriver inserted into the exposed center screw on the back of the clock module to gently lift the clock out of the endcap. Figure 2 Removing Clock b) Using the jeweler's screwdriver, remove the top small screw in the metal holder that keeps the battery in place. c) Loosen the other screw holding the metal holder. Swing the metal holder to the side. 15 16

7. Troubleshooting Guide If there is a problem with the recorder, first review the Typical Problem Descriptions and Recommended Solutions listed below. If assistance is needed, call the following number for customer support and/or arrangements for service of the recorder: Figure 3 Replacing Clock Battery d) Remove the used battery and dispose of it properly. e) Position the new battery in place with the + side facing the direction as shown in Figure 3. f) Reposition the metal holder and reinstall the first screw. Tighten the two screws. Re-insert the clock module into the recorder. g) Reset the time and date. Refer to the Operations section of this manual for information on setting the clock. Braemar, Inc. 1285 Corporate Center Drive, Suite 150 Eagan, MN 55121 USA Phone: 800.328.2719 Fax: 651.286.8630 E-mail: service@braemarinc.com Web: http://www.braemarinc.com 7.1 Problem Description and Recommended Solution Problem: Green LED is not blinking. Solution: - Ensure that a Flash Memory card of at least 10 MB capacity has been properly inserted in the recorder. - Install a new set of AA alkaline batteries which are known to be fully charged. New batteries MUST be used for each Holter recording. - Verify that the batteries are oriented according to the label in the bottom of the battery compartment. - Reinitialize by lifting one of the AA batteries for several seconds and then re-inserting. Problem: Digital clock is blank Solution: Replace clock battery by referring to the Maintenance section in this manual. - Note - The digital clock is independent from the operation of the DL700 and does not affect the recording. 17 18

Problem: Noisy ECG Recording Solution: - Ensure that all the electrodes are firmly and securely attached to the patient. (Refer to Electrode Attachment section). - Replace the entire lead set. (These leads are frequently broken inside the lead insulation due to someone pulling on the leadwire instead of at the base of the lead to remove it from the patient input connector). 8. Service Items Part Number 1 HeartStor card, 16 Mbytes 350-0147-01 2 HeartStor card, 32 Mbytes 350-0147-02 3 HeartStor card, 64 Mbytes 350-0147-03 4 Digital clock module 800-0364-01 5 Lead set, patient, 7 lead 200-1380-001 6 Lead set, patient, 5 lead 200-1380-002 7 ECG Test cable box 200-1588-001 8 Pouch with strap and belt 200-1508-001 9 Filler plugs 200-1586-001 10 Shoulder strap, pouch 100-1693-001 11 Belt strap, pouch 100-1694-001 19 20

Appendix A 9. Electrode Placement (7 Lead) Seven color coded leadwires are utilized to create a 3 channel ECG recording. 3 Channel Electrode Placement Chart: White: Red: Black: Brown: Blue: Channel 1 (-); Place on the right Manubrial border of the Sternum. Channel 1 (+); Place on the left Anterior Axillary line 6th rib. Channel 2 (-); Place on the left Manubrial border of the Sternum. Channel 2 (+); Place at approximately 1 inch right of the Xiphoid Process on the rib. Channel 3 (-); Place on the Center of the Manubrium. Orange: Channel 3 (+); Place on the left Mid-Clavicular line 6th rib. Green: Ground; Place on the lower right rib margin over bone. Channel Designation Channel 1: White - Red Channel 2: Black - Brown Channel 3: Blue - Orange 21 22

10. Electrode Placement (5 Lead) Five color coded leadwires are utilized to create a 2 channel ECG recording. 2 Channel Electrode Placement Chart: White: Red: Black: Brown: Green: Channel 1 (-); Place on the right Manubrial border of the Sternum. Channel 1 (+); Place on the left Anterior Axillary line 6th rib. Channel 2 (-); Place on the left Manubrial border of the Sternum. Channel 2 (+); Place at approximately 1 inch right of the Xiphoid Process on the rib. Ground; Place on the lower right rib margin over bone. Channel Designation Channel 1: White - Red Channel 2: Black - Brown Figure 4 7 Lead Electrode Placement 23 24

Figure 5 5 Lead Electrode Placement Braemar Inc. Phone: 800.328.2719 1285 Corporate Center Drive, Suite 150 Fax: 651.286.8630 Eagan, MN 55121 USA E-Mail: Service@BraemarInc.com Copyright 2006, Braemar Inc. All rights reserved 25