EEDEN technical data. air conditioning systems. Individual Control Systems

Similar documents
technical data Systems Individual control systems

Allows detailed and easy monitoring and operation of VRV systems (maximum 2 x 64 groups / indoor units)

CTXA-AS/AT/AW, FTXA-AS/AT/AW

OPERATION MANUAL. Remote controller BRC1D527

Allows detailed and easy monitoring and operation of VRV systems (maximum 2 x 64 groups / indoor units)

Air Conditioning Technical Data FVA-A > FVA71AMVEB > FVA100AMVEB > FVA125AMVEB > FVA140AMVEB

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXB-C

WIRED REMOTE CONTROLLER OPERATION MANUAL

Hello Madoka. The beauty of simplicity

Air Conditioning Technical Data FHA-A > FHA35AVEB > FHA50AVEB > FHA60AVEB > FHA71AVEB > FHA100AVEB > FHA125AVEB > FHA140AVEB

9. External Control Adaptor for Outdoor Unit

NETWORK SOLUTIONS. The ideal solution for control and management of maximum 1,024 VRV indoor units

QUICK REFERENCE. Remote controller BRC1E51

Submittal Data Sheet intelligent Touch Manager DCM601A71

Daikin HVAC Controls Guide Specification

Daikin Airconditioning UK Ltd. Allows detailed and easy monitoring and operation of VRV Systems (maximum 2 x 64 groups / indoor units)

Wireless Remote Controller Kit

Owner s Manual RBC-AX32U(W)-E RBC-AX32U(WS)-E AIR CONDITIONER (SPLIT TYPE) Wireless remote controller kit. Model name: English.

technical data air conditioning systems

Daikin HVAC Controls Guide Specification

User-friendly interface

Air Conditioning Technical Data FUA-A > FUA71AVEB > FUA100AVEB > FUA125AVEB

Air Conditioning Technical Data FBA-A > FBA35A2VEB > FBA50A2VEB > FBA60A2VEB > FBA71A2VEB > FBA100A2VEB > FBA125A2VEB > FBA140A2VEB

Hello Madoka. The beauty of simplicity

technical data air conditioning systems

Owner's Manual. Carrier TOSH BA REMOTE CONTROLLER FOR AIR CONDITIONER (SPLIT TYPE) Wireless remote controller kit TCB-AX21 UL

Installation Manual. DZK BACnet

Control. Systems. Climate comfort. All Seasons. Heating. Air Conditioning. Applied Systems. Refrigeration

OPERATION INSTRUCTIONS

Daikin HVAC Controls Guide Specification

Split. Air Conditioning Technical Data FTXM-M > FTXM20M2V1B > FTXM25M2V1B > FTXM35M2V1B > FTXM42M2V1B > FTXM50M2V1B > FTXM60M2V1B

Wall mounted units. Please read carefully and thoroughly this manual before operating this unit and save it in a safe place for future reference.

INTERFACE SPECIFICATION

Super Digital Inverter / RAV Series 2010 Technical training

RTD-NET Installation Instructions

Chilled Water REMOTE CONTROLLER OPERATION MANUAL MAN-O-CRC4AH intensity.mx

76 F. Ductless Split Air Conditioner. YR-E16b Wired Controller User Manual WARNING

Wired Controller Operation & Installation Manual

Installation, Start-up and Operating Instructions

SYSTEM OUTLINE KRP4A Group control adapter PCB (installation box is necessary)

I-Net. An intelligent approach to air conditioning management

OPERATION MANUAL. Room thermostat EKRTW

REMOTE CONTROLLER CS244-R OWNER S MANUAL

NOTE CONTENTS NOTE-CONTENTS

WIRED REMOTE CONTROLLER

PLXRMM1605. Wall Mounted. FT-A Series. COOLING ONLY [50Hz] V

Instruction Book. English. CITY MULTI Control System and Mitsubishi Mr. Slim Air Conditioners MA Remote Controller PAR-31MAA

I2:34 MODEL TSTATBBP2W01 PROGRAMMABLE DIGITAL THERMOSTAT. Heat only, or Cool only. Meets California Title 24 Residential USERS INFORMATION MANUAL

Accessories Control systems

REMOTE CONTROL USER MANUAL QUICK CONNECT MINI-SPLIT

Central Controller Operation & Installation Manual

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

Operation 6035 ENGLISH PROG MENU

IntesisBox SMS - Mitsubishi Electric air conditioners

SERVICE Manual DUCT TYPE AIR CONDITIONER. (Cool) OUTDOOR UNIT INDOOR UNIT TYPE UDH4400G DH44ZAX IDH4400A DH44ZA1(A2) ADH4400G DH44ZA1(A2)

The UP and DOWN buttons will toggle or scroll through the options in each section.

Model HM-535 Power Supply Installation and Service Instructions

Installation Manual RB-RWS20-E. Lite-Vision plus Remote Controller. Model name: English

User reference guide. Daikin PMS Interface. User reference guide Daikin PMS Interface. English

Operation Guide CT100

WIRED REMOTE CONTROLLER

DESIGN & TECHNICAL MANUAL

V0STAT51P-2 Programmable Wired Controller

Technical Note: Installation Note

SMMS i Selection Tool

Digital Room Thermostat

Smart heating system. with wireless thermostats & smartphone control for every room. Get the most out of any water based underfloor heating

intelligent Touch Controller Web Software

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書

Operation Guide CT101

REMOTE CONTROLLER OWNER'S MANUAL AIR CONDITIONER OWNER'S MANUAL ATI/AOU-53HPR1 ATI/AOU-105HPS3 ATI/AOU-140HPS3

Instruction Book. English. CITY MULTI Control System and Mitsubishi Mr. Slim Air Conditioners MA Remote Controller PAR-30MAA

Operation Guide CT32 ENGLISH

Lossnay Remote Controller

Model: DCS007A51 CB08A081A. DAIKIN Industries, Ltd. CB08A081A 1/23

Master room unit for RRV controllers

Zone Manager INSTALLATION MANUAL 40KMC KMQ QNC QNQ

IntesisBox DK-RC-MBS-1 v.0.8

Part 6 Control System

Ceiling Concealed Split System C Series

Central Controller G-50A/GB-50 Web Browser Operation Manual (For Managers)

MXM-50. Modbus Interface for Mitsubishi Air-Conditioning. Installation and User Guide.

Wireless LAN control

Control systems. Efficient room control

Temperature controller Ducted systems

SINGLE. Technical Data Book Zone Control Systems

VARIA VARIA 826 S WH KNX VARIA 826 S BK KNX D GB F I E NL. Installation and operating instructions Room thermostat VARIA 826 S KNX

Product Data. SYSTXBBUIZ01 -B EVOLUTIONt ZONE CONTROL. EVOLUTION t ZONE CONTROL

7-day room temperature controller

INSTALLATION MANUAL. Remote controller BRC315D7

Semi flush-mounted room temperature controllers with LCD

Product Manual SZ2141

Model: Available in : Sapphire Black and Glacier White

MM-A20 BMS Interface for Mitsubishi Electric Split Air-Conditioning

User Guide. Multipipe Units CMAA / RTMA CNT-SVU004B-GB

INSTALLATION MANUAL For authorized service personnel only.

FANCOIL CONTROLLER UNIT TC17B01KNX. Product Handbook

Wireless 7 Day Programmable Room Thermostat

LOW FOG 3000 FT USER MANUAL. Version: 1.0. ROBE Lighting s.r.o. Czech Republic

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

Transcription:

EEDEN08-204 technical data Individual Control Systems air conditioning systems 2e

TABLE OF CONTENTS Individual control systems 1 Possible individual control systems.............................. 21 Survey................................................................ 4 2 BRC2C51 - Simplified remote control............................ 5 Explanation of buttons and functions................................ 5 3 BRC3A61 - Simplified remote control for hotel applications.. 6 Dimensional drawing................................................. 6 Explanation of buttons and functions................................ 7 4 BRC1D52 - Wired remote control................................ 8 Dimensional drawing................................................. 8 Explanation of buttons and functions................................ 9 5 BRC4C61,62,63,64 - Infrared remote control.................. 11 Dimensional drawing................................................ 11 Explanation of buttons and functions............................... 12 6 BRC7C62,67 - Infrared remote control......................... 13 Dimensional drawing................................................ 13 Explanation of buttons and functions............................... 14 7 BRC7F533F,532F - Infrared remote control................... 15 Dimensional drawing................................................ 15 7 BRC7F533F,532F - Infrared remote control................... 16 Explanation of buttons and functions............................... 16 8 BRC7E531W,530W - Infrared remote control................. 17 Dimensional drawing................................................ 17 9 BRC7E63W,66 - Infrared remote control....................... 18 Dimensional drawing................................................ 18 Explanation of buttons and functions............................... 19 10 BRC7E618,619 - Infrared remote control...................... 20 Dimensional drawing................................................ 20 11 Survey of various control systems.............................. 21 VRV Systems Control Systems 1

1 Possible individual control systems Simplified remote control - BRC2C51 Simplified remote control for hotel applications - BRC3A61 compact, user friendly unit ideal for use in hotel bedrooms Infrared remote control - BRC4C* / BRC7C* simple, compact and easy to operate unit suitable for use in hotel bedrooms Operation buttons: Operation buttons: Operation buttons: ON / OFF ON / OFF ON / OFF Operation mode selection Fan speed control Timer mode start / stop Fan speed control Temperature setting Timer mode on / off Temperature setting Programmed time Temperature setting Air flow direction (FXHQ, FXFQ, FXCQ and FXAQ models only) Operating mode Fan speed control Filter sign reset Inspection test / operation Display Display Display Cool / heat changeover control Heat Recovery Ventilation (HRV) in operation Operating mode Heat Recovery Ventilation (HRV) in operation Set temperature Battery change Set temperature Operating mode Set temperature Operating mode Centralised control indication Air flow direction (FXHQ, FXFQ, FXCQ and FXAQ Centralised control indication Fan speed models only) Fan speed Defrost / hot start Programmed time Defrost / hot start Malfunction Inspection test / operation Malfunction adjustment Fan speed Operating mode selection Fan speed control Filter sign reset Inspection test / operation 2 VRV Systems Control Systems

1 Possible individual control systems BRC1D52 Wired remote control - BRC1D52 Limit operation (min./max.): room temperature is controlled within adjustable upper and lower limits. Limit operation can be activated manually or by schedule timer Real time clock: indicates real time and day Schedule timer: -It is possibie to programme a weekly schedule timer -It is possible to programme the remote control for each day of the week. Five day actions can be set as follows: -set point: unit is switched ON and normal operation is maintained -OFF: unit is switched OFF -limits: unit is switched ON and min./max. control (cf.limit operation for more details) Home leave (frost protection): during absence, the indoor temperature can be maintained at a certain level. This function can also switch the unit ON/OFF Different levels of disabled buttons can be selected as follows: level 1: all buttons are accessible level 2: all buttons are disabled except for: ON/OFF set temperature up/down fan speed cooling/heating mode enable/disable schedule timer air flow direction adjustment button Level 3: all buttons are disabled except for: ON/OFF set temperature up/down fan speed User friendly HRV function, thanks to the introduction of a button for ventilation mode and fan speed Constantly monitoring of the system for malfunctions in a total of 80 components Immediate display of fault location and condition Reduction of maintenance time and costs Operation buttons: ON / OFF Timer mode start / stop Timer on / off Programmed time Temperature setting Air flow direction adjustment Operating mode selection Fan speed control Filter sign reset Inspection test / operation Display Operating mode Heat Recovery Ventilation (HRV) in operation Cool / heat changeover control Centralised control indication Group control indication Set temperature Air flow direction Programmed time Inspection test / operation Fan speed Clean air filter Defrost / hot start Malfunction VRV Systems Control Systems 3

1 Possible individual control systems 1-1 Survey DESCRIPTION FXZQ FXFQ FXCQ FXKQ FXDQ FXDQ-N FXSQ FXMQ FXAQ FXHQ FXUQ FXLQ FXNQ Wired remote control BRC1D52 Infrared remote control cooling only BRC7E531W BRC7F533F BRC7C67 BRC4C63 BRC4C64 BRC4C64 BRC4C64 BRC4C64 BRC7E619 BRC7E66 BRC7C529W BRC4C64 BRC4C64 heat pump BRC7E530W BRC7F532F BRC7C62 BRC4C61 BRC4C62 BRC4C62 BRC4C62 BRC4C62 BRC7E618 BRC7E63W BRC7C528W BRC4C62 BRC4C62 Simplified remote control - - - - BRC2C51 BRC2C51 BRC2C51 BRC2C51 - - - BRC2C51 BRC2C51 Simplified remote control for hotel use - - - - BRC3A61 BRC3A61 BRC3A61 BRC3A61 - - - BRC3A61 BRC3A61 4 VRV Systems Control Systems

2 BRC2C51 - Simplified remote control 2-1 Explanation of buttons and functions 1 ON/OFF BUTTON Press the button and the system will start. Press the button again and the system will stop. 8 DISPLAY (FAN SPEED) The display shows the fan speed: HIGH or LOW. 2 OPERATION LAMP (RED) The lamp lights up during operation and blinks in case of stop due to malfunction. DISPLAY (CHANGEOVER UNDER CONTROL) 9 DISPLAY (DEFROST/HOT START) Indicates that defrost or hot start (during which the fan is stopped till the temperature of air supply rises enough at the start of a heating run) is in progress. 3 4 It is impossible to changeover heat/cool with the remote controller when it shows this display. (As for details, see SETTINGS OF MASTER REMOTE CONTROL in the operation manual attached to the indoor unit.). DISPLAY,, OPTION (VENTILATION / AIR CLEANING) This display shows that the total heat exchange unit and the air cleaning unit are in operation. (These are optional accessories.). 10 TEMPERATURE SETTING BUTTON Use this button for SETTING TEMPERATURE of the thermostat. ; Each press raises the set temperature by 1 C. ; Each press lowers the set temperature by 1 C. The variable temperature range is 16 C tot 32 C. 5 DISPLAY C (SET TEMPERATURE) This display shows the set temperature. Only given during a cooling or heating operation. 11 FAN SPEED CONTROL BUTTON Press this button to select the fan speed, HIGH or LOW, of your choice. 6 7 DISPLAY (OPERATION MODE) This display shows the current OPERATION MODE. is not available with outdoor units specially designed for cooling only. is reserved only for outdoor units capable of heat recovery. DISPLAY (UNDER CENTRALIZED CONTROL) When this display shows, the system is UNDER CENTRALIZED CONTROL. (This is not a standard specification) 12 13 OPERATION MODE SELECTOR BUTTON Press this button to select OPERATION MODE. DISPLAY (MALFUNCTION) Indicates malfunction and blinks if the unit stops operating due to the malfunction. (As for details, see TROUBLE SHOOTING in the operation manual attached to the indoor unit.) NOTE 1 Please note that the display shows all indications for the purpose of explanation only. This is contrary to actual running situations. VRV Systems Control Systems 5

3 BRC3A61 - Simplified remote control for hotel applications 3-1 Dimensional drawing (Unit: mm) 2-5 x 9 Slot (Fixing hall) BRC3A61 FXSQ FXMQ FXDQ FXLQ/FXNQ 3D013859A 6 VRV Systems Control Systems

3 BRC3A61 - Simplified remote control for hotel applications 3-2 Explanation of buttons and functions 1 2 ON/OFF BUTTON Press the button and the system will start. Press the button again and the system will stop. OPERATION LAMP (RED) The lamp lights up during operation or blinks if a malfunction occurs. DISPLAY, (VENTILATION / AIR CLEANING) 3 This display shows that the total heat exchange unit is in operation. (These is an optional accessory). 4 DISPLAY (SET TEMPERATURE) C This display shows the set temperature. Only given during a cooling or heating operation. DISPLAY (OPERATION MODE) This display shows the current OPERATION MODE. 5 is not available with outdoor units specially designed for cooling only. is reserved only for heat recovery outdoor units. DISPLAY (UNDER CENTRALIZED CONTROL) 6 When this display shows, the system is UNDER CENTRALIZED CONTROL. (This is not a standard specification) 7 8 9 10 11 DISPLAY (FAN SPEED) The display shows the set fan speed: HIGH or LOW. DISPLAY (DEFROST/HOT START) Indicates that defrost or hot start (during which the fan is stopped till the temperature of air supply rises enough at the start of a heating run) is in progress. TEMPERATURE SETTING BUTTON Use this button for SETTING TEMPERATURE of the thermostat. ; Each press raises the set temperature by 1 C. ; Each press lowers the set temperature by 1 C. The variable temperature range is 16 C tot 32 C. FAN SPEED CONTROL BUTTON Press this button to select the fan speed, HIGH or LOW, of your choice. DISPLAY (MALFUNCTION) Indicates malfunction and blinks if the unit stops operating due to the malfunction. (As for details, see TROUBLE SHOOTING in the operation manual attached to the indoor unit.) NOTES 1 Please note that the display shows all indications for the purpose of explanation only. This is contrary to actual running situations. 2 This remote controller does not have AIR FLOW DIRECTION ADJUST BUTTON. Don t operate the flap adjusting air flow direction by your hand. (FXFQ, FXCQ, FXAQ, FXKQ) VRV Systems Control Systems 7

4 BRC1D52 - Wired remote control 4-1 Dimensional drawing (Unit: mm) 5 x 10 (Round end slit) 6,5 x 9 (Round end slit) 5 x 7 (Round end slit) Hole ø5 Cover closed Cover open 3TW23651-2 8 VRV Systems Control Systems

4 BRC1D52 - Wired remote control 4-2 Explanation of buttons and functions 3 6 23 7 8 9 2 1 4 12 14 17 10 11 22 25 16 13 15 18 19 20 21 5 24 29 33 26 35 27 36 37 28 30 31 32 34 1 2 3 4 5 6 7 8 9 10 11 12 ON/OFF BUTTON Press the ON/OFF button to start or stop the system. OPERATION LAMP The operation lamp lights up during operation or blinks if a malfunction occurs. OPERATION MODE ICON These icons indicate the current operation mode (FAN, DRY, AUTOMATIC, COOLING, HEATING). VENTILATION MODE ICON,, These icons indicate the current ventilation mode (HRV only) (AUTOMATIC, HEAT EXCHANGE, BYPASS). 13 14 15 16 MNIIMUM SET TEMPERATURE C The minimum set temperature indicates the minimum set temperature when in limit operation. SCHEDULE TIMER ICON This icon indicates that the schedule timer is enabled. ACTION ICONS These icons indicate the actions for each day of the schedule timer. OFF ICON OFF This icon indicates that the OFF action is selected when programming the schedule timer. VENTILATION ICON INSPECTION REQUIRED and 17 The ventilation icon appears when the ventilation is adjusted with the ventilation amount button (HRV only). These icons indicate that inspection is required. Consult your installer. Simultaneously, the ventilation amount is indicated by the fan speed icon (see 22). SET TEMPERATURE DISPLAY C AIR CLEANING ICON 18 This indicates the current set temperature of the installation (not shown in LIMIT operation or in This icon indicates that the air cleaning unit (option) is operational. FAN or DRY mode). LEAVE HOME ICON SETTING 19 The leave home icon shows the status of the leave home function. Not used, for service purposes only. ON Leave home is enabled AIR FLOW DIRECTION ICON 20 FLASHING Leave home is active This icon indicates the air flow direction (only for installations with motorised air flow flaps). OFF Leave home is disabled 21 NOT AVAILABLE EXTERNAL CONTROL ICON This is displayed whenever a non-installed option is addressed or a function is not available. This icon indicates that another controller with higher priority is controlling or disabling your installation. FAN SPEED ICON 22 CHANGE-OVER UNDER CENTRALISED CONTROL ICON This icon indicates the set fan speed. This icon indicates that the change-over of the installation is under centralised control assigned to another DEFROST/HOTSTART MODE ICON indoor unit or optional cool/heat selector connected to the outdoor unit (= master remote controller). 23 This icon indicates that the defrost/hotstart mode is active. DAY OF THE WEEK INDICATOR AIR FILTER CLEANING TIME ICON 24 The day of the week indicator shows the current week day (or the set day when reading or This icon indicates the air filter must be cleaned. Refer to the manual of the indoor unit. programming the schedule timer). ELEMENT CLEANING TIME ICON 25 CLOCK DISPLAY This icon indicates the element must be cleaned (HRV only). The clock display indicates the current time (or the action time when reading or programming the schedule timer). VENTILATION MODE BUTTON 26 MAXIMUM SET TEMPERATURE C The ventilation mode button operates the HRV; refer to the HRV manual for more details. The maximum set temperature indicates the maximum set temperature when in limit operation. VRV Systems Control Systems 9

4 BRC1D52 - Wired remote control 4-2 Explanation of buttons and functions 3 6 23 7 8 9 2 1 4 12 14 17 10 11 22 25 16 13 15 18 19 20 21 5 24 29 33 26 35 27 36 37 28 30 31 32 34 27 28 29 30 31 32 VENTILATION AMOUNT BUTTON OPERATION CHANGE/MIN-MAX BUTTON This button sets the ventilation amount; refer to the HRV manual for more details. This button is a multi-purpose button. Depending on the previous manipulations of the user, it INSPECTION/TEST OPERATION BUTTON TEST 33 can have following functions: Not used, for service purposes only. 1 select the operation mode of the installation (FAN, DRY, AUTOMATIC, COOLING, HEATING) PROGRAMMING BUTTON 2 toggle between minimum temperature and maximum temperature when in limit operation This button is a multi-purpose button. SETPOINT/LIMIT BUTTON 34 Depending on the previous manipulations of the user, the programming button can have various functions. This button toggles between setpoint, limit operation or OFF (programming mode only). SCHEDULE TIMER BUTTON FAN SPEED BUTTON 35 This button enables or disables the schedule timer. This button toggles between L (Low), H (High), HH (very High), (Automatic). TIME ADJUST BUTTON AIR FLOW DIRECTION ADJUST BUTTON 36 These buttons are used to adjust the clock or, when in programming mode, to adjust the This button enables to adjust the air flow direction. programmed action time. Both buttons have an auto-repeat function. AIR FILTER CLEANING TIME ICON RESET BUTTON 37 TEMPERATURE ADJUST BUTTON This button is used to reset the air filter cleaning time icon. These buttons are used to adjust the current setpoint or, when in programming mode, to adjust the programmed setpoint temperature (step = 1 C). Both buttons are also used to adjust the day of the week. 10 VRV Systems Control Systems

5 BRC4C61,62,63,64 - Infrared remote control 5-1 Dimensional drawing (Unit: mm) Remote control dimensions Transmitting Receiver Remote control holder installation procedure (installation to wall surface) Service space for ceiling installation 2-5 x 9 slot Switch box (Field supplied parts) Liquid crystal infrared remote control Remote control holder NOTES More than 90 (service space) 1 Do not install more than 3 receivers in the vicinity of one another. 2 With 4 or more units, there is always the possibility of malfunction (Ceiling opening) BRC4C62 BRC4C64 BRC4C61 BRC4C63 Heat pump Cooling only Heat pump Cooling only FXSQ, FXDQ, FXMQ, FXLQ, FXNQ FXKQ (Ceiling opening) 3D007898 VRV Systems Control Systems 11

5 BRC4C61,62,63,64 - Infrared remote control 5-2 Explanation of buttons and functions 1 2 3 4 DISPLAY (SIGNAL TRANSMISSION) 13 TIMER RESERVE/CANCEL BUTTON This lights up when a signal is being transmitted. 14 AIR FLOW DIRECTION ADJUST BUTTON (BRC4C61,63 only) DISPLAY (OPERATION MODE) OPERATION MODE SELECTOR BUTTON 15 This display shows the current OPERATION MODE. For cooling only type, (Auto) and Press this button to select OPERATION MODE. (Heating) are not installed. 16 FILTER SIGN RESET BUTTON DISPLAY H M L C (SET TEMPERATURE) This display shows the set temperature. DISPLAY (PROGRAMMED TIME) This display shows PROGRAMMED TIME of the system start or stop. INSPECTION/TEST OPERATION BUTTON 17 This button is used only by qualified service persons for maintenance purposes. EMERGENCY OPERATION SWITCH 18 This switch is readily used if the remote control does not work. 5 DISPLAY (AIR FLOW FLAP) (BRC4C61,63 only) RECEIVER 19 DISPLAY (FAN SPEED) This receives the signals from the remote control. 6 The display shows the set fan speed. OPERATING INDICATOR LAMP (RED) 20 DISPLAY (INSPECTION/TEST OPERATION) This lamp stays lit while the air conditioner runs. It flashes when the unit is in trouble. 7 When the INSPECTION/TEST OPERATION BUTTON is pressed, the display shows the system mode is in. TIMER INDICATOR LAMP (GREEN) 21 ON/OFF BUTTON This lamp stays lit while the timer is set. 8 Press the button and the system will start. Press the button again and the system will stop. AIR FILTER CLEANING TIME INDICATOR LAMP (RED) 22 FAN SPEED CONTROL BUTTON Lights up when it is time to clean the air filter. 9 Press this button to select the fan speed, HIGH or LOW, of your choice. DEFROST LAMP (ORANGE) 23 TEMPERATURE SETTING BUTTON Lights up when the defrosting operation has started. (For straight cooling type this lamp does not turn on.) 10 Use this button for SETTING TEMPERATURE. (Operates with the front cover of the remote control closed.) FAN/AIR CONDITIONING SELECTOR SWITCH 24 PROGRAMMING TIME BUTTON Set the switch to (FAN) for FAN and (A/C) for HEAT or COOL. 11 Use this button for programming START and/or STOP time. (Operates with the front cover of the remote control closed.) COOL/HEAT CHANGEOVER SWITCH 25 12 TIMER MODE START/STOP BUTTON Set the switch to (COOL) for COOL and (HEAT) for HEAT. NOTES 1 Please note that the display shows all indications for the purpose of explanation only. This is contrary to actual running situations. 2 Figure 2 shows the remote control with the front cover opened. 12 VRV Systems Control Systems

6 BRC7C62,67 - Infrared remote control 6-1 Dimensional drawing (Unit: mm) Remote control dimensions Transmitting part Receiver installation procedure Decoration panel Receiver Remote control holder installation procedure (installtion to wall surface) Liquid crystal infrared remote control Receiver detail Remote control holder BRC7C62 BRC7C67 Heat pump Cooling only FXCQ 3D007588A VRV Systems Control Systems 13

6 BRC7C62,67 - Infrared remote control 6-2 Explanation of buttons and functions 1 DISPLAY (SIGNAL TRANSMISSION) 13 TIMER RESERVE/CANCEL BUTTON This lights up when a signal is being transmitted. 14 AIR FLOW DIRECTION ADJUST BUTTON DISPLAY (OPERATION MODE) OPERATION MODE SELECTOR BUTTON 15 2 This display shows the current OPERATION MODE. For cooling only type, (Auto) and Press this button to select OPERATION MODE. (Heating) are not installed. 16 FILTER SIGN RESET BUTTON H M L DISPLAY (SET TEMPERATURE) INSPECTION/TEST OPERATION BUTTON C 3 17 This display shows the set temperature. This button is used only by qualified service persons for maintenance purposes. DISPLAY (PROGRAMMED TIME) EMERGENCY OPERATION SWITCH 4 18 This display shows PROGRAMMED TIME of the system start or stop. This switch is readily used if the remote control does not work. 5 DISPLAY (AIR FLOW FLAP) RECEIVER 19 DISPLAY (FAN SPEED) This receives the signals from the remote control. 6 The display shows the set fan speed. OPERATING INDICATOR LAMP (RED) 20 DISPLAY (INSPECTION/TEST OPERATION) This lamp stays lit while the air conditioner runs. It flashes when the unit is in trouble. 7 When the INSPECTION/TEST OPERATION BUTTON is pressed, the display shows the system mode is in. TIMER INDICATOR LAMP (GREEN) 21 ON/OFF BUTTON This lamp stays lit while the timer is set. 8 Press the button and the system will start. Press the button again and the system will stop. AIR FILTER CLEANING TIME INDICATOR LAMP (RED) 22 FAN SPEED CONTROL BUTTON Lights up when it is time to clean the air filter. 9 Press this button to select the fan speed, HIGH or LOW, of your choice. DEFROST LAMP (ORANGE) 23 TEMPERATURE SETTING BUTTON Lights up when the defrosting operation has started. (For straight cooling type this lamp does not turn on.) 10 Use this button for SETTING TEMPERATURE. (Operates with the front cover of the remote control closed.) FAN/AIR CONDITIONING SELECTOR SWITCH 24 PROGRAMMING TIMER BUTTON Set the switch to (FAN) for FAN and (A/C) for HEAT or COOL. 11 Use this button for programming START and/or STOP time. (Operates with the front cover of the COOL/HEAT CHANGEOVER SWITCH remote control closed.) 25 12 TIMER MODE START/STOP BUTTON Set the switch to (COOL) for COOL and (HEAT) for HEAT. NOTES 1 Please note that the display shows all indications for the purpose of explanation only. This is contrary to actual running situations. 2 Figure 2 shows the remote control with the front cover opened. 14 VRV Systems Control Systems

7 BRC7F533F,532F - Infrared remote control 7-1 Dimensional drawing FXFQ-P Remote control dimensions Receiver installation procedure Transmitting part Pipe connection side Receiver Drain connection side Remote control holder installation procedure (installation to wall surface) Liquid crystal - remote control (wireless) Receiver detail Decoration panel Remote control holder Wireless remote control kit for eacht decoration panel Wireless remote control kit BRC7F532F BRC7F533F Decoration panel BYCQ140CW1 3D056851 VRV Systems Control Systems 15

7 BRC7F533F,532F - Infrared remote control 7-2 Explanation of buttons and functions 1 2 3 4 DISPLAY (SIGNAL TRANSMISSION) 13 TIMER RESERVE/CANCEL BUTTON This lights up when a signal is being transmitted. 14 AIR FLOW DIRECTION ADJUST BUTTON DISPLAY (OPERATION MODE) OPERATION MODE SELECTOR BUTTON 15 This display shows the current OPERATION MODE. For cooling only type, (Auto) and Press this button to select OPERATION MODE. (Heating) are not installed. 16 FILTER SIGN RESET BUTTON DISPLAY H M L C (SET TEMPERATURE) This display shows the set temperature. DISPLAY (PROGRAMMED TIME) This display shows PROGRAMMED TIME of the system start or stop. INSPECTION/TEST OPERATION BUTTON 17 This button is used only by qualified service persons for maintenance purposes. EMERGENCY OPERATION SWITCH 18 This switch is readily used if the remote control does not work. 5 DISPLAY (AIR FLOW FLAP) RECEIVER 19 DISPLAY (FAN SPEED) This receives the signals from the remote control. 6 The display shows the set fan speed. OPERATING INDICATOR LAMP (RED) 20 DISPLAY (INSPECTION/TEST OPERATION) This lamp stays lit while the air conditioner runs. It flashes when the unit is in trouble. 7 When the INSPECTION/TEST OPERATION BUTTON is pressed, the display shows the system mode is in. TIMER INDICATOR LAMP (GREEN) 21 ON/OFF BUTTON This lamp stays lit while the timer is set. 8 Press the button and the system will start. Press the button again and the system will stop. AIR FILTER CLEANING TIME INDICATOR LAMP (RED) 22 FAN SPEED CONTROL BUTTON Lights up when it is time to clean the air filter. 9 Press this button to select the fan speed, HIGH or LOW, of your choice. DEFROST LAMP (ORANGE) 23 TEMPERATURE SETTING BUTTON Lights up when the defrosting operation has started. (For straight cooling type this lamp does not turn on.) 10 Use this button for SETTING TEMPERATURE. (Operates with the front cover of the remote control closed.) FAN/AIR CONDITIONING SELECTOR SWITCH 24 PROGRAMMING TIME BUTTON Set the switch to (FAN) for FAN and (A/C) for HEAT or COOL. 11 Use this button for programming START and/or STOP time. (Operates with the front cover of the remote control closed.) COOL/HEAT CHANGEOVER SWITCH 25 12 TIMER MODE START/STOP BUTTON Set the switch to (COOL) for COOL and (HEAT) for HEAT. NOTES 1 Please note that the display shows all indications for the purpose of explanation only. This is contrary to actual running situations. 2 Figure 2 shows the remote control with the front cover opened. 16 VRV Systems Control Systems

8 BRC7E531W,530W - Infrared remote control 8-1 Dimensional drawing (Unit: mm) Receiver installation procedure Remote control dimensions Transmitting part Drain piping side Refrigerant piping side Receiver Liquid crystal remote control (wireless) Remote control holder installation procedure (Installation to wall survace) Receiver detail Decoration panel (BYFQ60BW1) Remote control holder BRC7E531W BRC7E530W Cooling only Heat pump FXZQ 3D038937 VRV Systems Control Systems 17

9 BRC7E63W,66 - Infrared remote control 9-1 Dimensional drawing (Unit: mm) Remote control dimensions Transmitting part Receiver installation procedure Receiver Remote control holder installation procedure (installation to wall surface) Liquid crystal infrared remote control Receiver detail Remote control holder BRC7E63W BRC7E66 Heat pump Cooling only FXHQ 3D028963 18 VRV Systems Control Systems

9 BRC7E63W,66 - Infrared remote control 9-2 Explanation of buttons and functions 1 2 3 4 DISPLAY (SIGNAL TRANSMISSION) 13 TIMER RESERVE/CANCEL BUTTON This lights up when a signal is being transmitted. 14 AIR FLOW DIRECTION ADJUST BUTTON DISPLAY (OPERATION MODE) OPERATION MODE SELECTOR BUTTON 15 This display shows the current OPERATION MODE. For cooling only type, (Auto) and Press this button to select OPERATION MODE. (Heating) are not installed. 16 FILTER SIGN RESET BUTTON DISPLAY H M L C (SET TEMPERATURE) This display shows the set temperature. DISPLAY (PROGRAMMED TIME) This display shows PROGRAMMED TIME of the system start or stop. INSPECTION/TEST OPERATION BUTTON 17 This button is used only by qualified service persons for maintenance purposes. EMERGENCY OPERATION SWITCH 18 This switch is readily used if the remote control does not work. 5 DISPLAY (AIR FLOW FLAP) RECEIVER 19 DISPLAY (FAN SPEED) This receives the signals from the remote control. 6 The display shows the set fan speed. OPERATING INDICATOR LAMP (RED) 20 DISPLAY (INSPECTION/TEST OPERATION) This lamp stays lit while the air conditioner runs. It flashes when the unit is in trouble. 7 When the INSPECTION/TEST OPERATION BUTTON is pressed, the display shows the system mode is in. TIMER INDICATOR LAMP (GREEN) 21 ON/OFF BUTTON This lamp stays lit while the timer is set. 8 Press the button and the system will start. Press the button again and the system will stop. AIR FILTER CLEANING TIME INDICATOR LAMP (RED) 22 FAN SPEED CONTROL BUTTON Lights up when it is time to clean the air filter. 9 Press this button to select the fan speed, HIGH or LOW, of your choice. DEFROST LAMP (ORANGE) 23 TEMPERATURE SETTING BUTTON Lights up when the defrosting operation has started. (For straight cooling type this lamp does not turn on.) 10 Use this button for SETTING TEMPERATURE. (Operates with the front cover of the remote control closed.) FAN/AIR CONDITIONING SELECTOR SWITCH 24 PROGRAMMING TIME BUTTON Set the switch to (FAN) for FAN and (A/C) for HEAT or COOL. 11 Use this button for programming START and/or STOP time. (Operates with the front cover of the remote control opened.) COOL/HEAT CHANGEOVER SWITCH 25 12 TIMER MODE START/STOP BUTTON Set the switch to (COOL) for COOL and (HEAT) for HEAT. NOTES 1 Please note that the display shows all indications for the purpose of explanation only. This is contrary to actual running situations. 2 Figure 2 shows the remote control with the front cover opened. VRV Systems Control Systems 19

10 BRC7E618,619 - Infrared remote control 10-1 Dimensional drawing (Unit: mm) Remote control dimensions Transmitting part Receiver installation procedure 157 Receiver 62 17.5 Receiver detail Remote controller holder installation procedure (Installation to wall surface) Liquid crystal remote control (Wireless) Remote controller holder BRC7E618 BRC7E619 Heat pump Cooling only FXAQ 3D034905 20 VRV Systems Control Systems

11 Survey of various control systems For more effective localized environmental control Daikin offers various control systems such as single or double remote control or centralized control. This enables the construction of a variety of operational control systems which can be adapted for various uses from remote control to building automation (BA). Control method Objective / use Unit name and model Outline of system Function Standard number of units Local operation of remote control Remote operation of remote control 2 remote controls Group control (1) Group control by 2 remote controls (1) Forced OFF command from outside Combining control by remote control For control from a distant place For control from 2 places (remote or local) Control of several indoor units on a floor at the same time For above control from distant place If forgotten to turn equipment off, or in case of emergency Operation of other equipment combined with the operation of indoor unit BRC1D52 2 BRC2C51 Connected to indoor units For group control it is connected to 1 unit out of the group In case of control by 2 remote controls both controls are connected to the indoor unit Remote control Remote control Remote control Each up to 500m in length Remote control (V0092) Remote control Each up to 500m in length Remote control Remote control Interunit wiring may be up to 500m in length Remote control Up to 16 indoor units may (V0094) be connected Remote control Remote For local operation of remote control Forced /OFF input Remote control For HRV system (V0091) (V0093) Remote control Interunit wiring may be up to 500m in length control Up to 16 indoor units may be connected (V0095) Forced For group control /OFF input Forced ON/OFF Remote control input HRV Remote control (V0098) Remote control (V0097) Operational functions Start/Stop (ON/OFF) Temperature setting Timer setting (Settings in units of 1 hour up to a maximum of 72 hours) Air flow setting Air flow direction adjustment (Swing flap) BRC1A51 only Indication function Operating display Program dry function display Defrost/Hot start display Filter sign Temperature setting display Timer display Air flow display Abnormal operation display In case of group control all the indoor units in the system are set to the same value and each unit is controlled individually by its internal thermostat. (Not by the thermostat equipped in remote control) In common case of double remote control the most recent takes priority. (Selection between master Forcibly stops indoor unit operation by command from outside. During remote control group control, input a command from outside to any one of the indoor Operates HRV in accordance with indoor unit operation. In case of group control, the thermostat equipped in remote control is not available. 1 remote control controls 1 indoor unit 2 remote controls control 1 indoor unit 1 remote control controls up to 16 indoor units simultaneously 2 remote controls control up to 16 indoor units from 2 different places simultaneously Same as the number of units controlled by remote control Same as the number of units controlled by remote control NOTES 1 In case of group control, the remote control used as master control must be selected with auto-swing function (BRC1A51, 61). When the group has cassette or ceiling suspended or cassette corner or wall mounted models. 2 In case of using BRC2C51 (S-REMOCON) to heat recovery series, be sure not to use this independently. Use with other remote controls (BRC1A51 52, KRC19-26 or DCS302A51). VRV Systems Control Systems 21

2e Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intension to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste. Naamloze Vennootschap Zandvoordestraat 300 B-8400 Oostende, Belgium www.daikin.eu BTW: BE 0412 120 336 RPR Oostende Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment. Daikin units comply with the European regulations that guarantee the safety of the product. VRV products are not within the scope of the Eurovent certification programme. The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, In the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.. EEDEN08-204 01/2008 Copyright Daikin The present publication supersedes EEDEN07-200 Prepared in Belgium by Lannoo (www.lannooprint.be), a company whose concern for the environmont is set in the EMAS and ISO 14001 systems. Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B- 8400 Oostende ÈEEDEN08-204aËÍ