MTD75 Comprehensive cooling tower controller with all the functions required for dosing and control of cooling water

Similar documents
BXD17 Series. Features. Analytical instrumentation for your measurement applications.

MXD70 SERIES. Instrumentation to meet your Process Requirements. Features.

Electronic Dosing Systems Ltd

Neon pr. ph/ ORP measurement. Applications. Description

LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F

Control and automatic dosing

mxcontrol Multifunction Controller

WebMaster. Cooling Tower/Boiler Controller. ONE simple and flexible controller for ALL your water treatment needs! SUMMARY OF KEY FEATURES

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

T80 Universal Transmitter S80 Intelligent Sensors

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

HPT63 ph / REDOX TRANSMITTER

Measure & Control Temperature & CO2 levels with analog & digital I/O

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication.

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

Conductivity Transmitters

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Instruction Manual. BMS CARD Model: DP-OPT-CARD-OP. Supplied by: - Retrofit to (or supplied with) DIGICHEM Plus + Controllers

*suitable both for membrane sensors or chlorine open cell

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Trident and Trident X2 Digital Process and Temperature Panel Meter

MXD70 SERIES. Multi-parameter Monitor. ph / Redox Setup and Operating Guide

Wall-/Pipe Mounted Universal Process Indicator

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Micro Motion Model 7950 and Model 7951 Signal Converters

Simplified information where and how you want it.

Signet 9900 Transmitter

WebMaster. Cooling Tower/Boiler Controller. ONE simple and flexible controller for ALL your water treatment needs! SUMMARY OF KEY FEATURES

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB84PH ph /ORP / pion transmitter

Summary of Features and Benefits

High Voltage DC Meter

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

DM650TM SENSOR / WALL MOUNTED TEMPERATURE DISPLAY

Thermo Scientific AquaPro Multi-Input Intelligent Process Analyzer

Controllers. Water Treatment

+GF+ SIGNET 5800CR Conductivity/Resistivity Monitor Instructions

Industrial Water Treatment Controllers

HIGH-VOLTAGE DC METER

GFC111-MB. Flow Computer With RS485 MODBUS FEATURES 1. DESCRIPTION APPLICATIONS

Multiparameter Waterproof Meters. Multiparameter measurement in compact, IP67 rated waterproof enclosures

Temperature/Process Controllers Manual

Power Meter PowerMonitor 500

User friendly and easy to program

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

C160 Wall-/Pipe Mounted Universal Process Indicator

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

WebMaster WIND. Industrial Water Controller OVERVIEW SUMMARY OF KEY BENEFITS

SIGNET 5700 ph/orp Monitor - ORP Instructions

How to build a Conductivity Measurement System

MID approval no. DE-08-MI004-PTB004 Date of release

Microprocessor Resistivity & Conductivity Monitor/Controller EC410 / EC430. Operation Manual

SX90 Process Controller

Series TFXB Ultra. Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel

Analog outputs Output 1 + 2: 0(4) 20 ma or 0 10 V. Configurable as - analog process value output - continuous controller output (PID action)

Digital Indicator Solutions

Microprocessor ph/orp Controller

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

BACnet. b3810 Series Local Controllers

/8 DIN Universal Process Indicator

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Millenium 3 logic controllers

CONTROLLERS. Chemical Injection skids. Water Quality Monitoring Systems cum dosing (WQMSD) Mobile Disinfection/Dosing systems

NF770 Temperature Compensation Liquid Flow Computer

MODEL 8000MP LEVEL SENSOR

LAUREL ELECTRONICS, INC.

with Backlight Graphic LCD Screen

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

NF760 Batch Controller

BL121 Pool & Spa Controller. ph/orp Swimming Pool Controller with Built-In Chemical Feed Pumps

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

OPERATION MANUAL MODEL TT-LP

Andover ContinuumTM. b3850 Series Terminal Controllers

16 pools with just one central unit with ProMinent The new swimming pool controller DULCOMARIN II

HART UNIVERSAL TEMPERATURE TRANSMITTER

Commander circular chart recorders The tried and tested solution for process recording

LDCL DIGITAL CONTROLLER OPERATING MANUAL

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

SHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions

Process Analysis Systems. Stratos Pro A4 MSPH/MSPH. Chem Energy Pharm Food Water. Connection

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

Andover ContinuumTM Infinet II

Recorders for all applications

APP 700 Technical Specification

RTD-W Installation Instructions

Safety. 2. Configuration - Operation 2.1 RTD Selection 2.2 Driver Test Header. 3. Diagnostics 3.1 ph Input 3.2 Temperature Input

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

GENERAL SAFETY GUIDELINES

Instruction Sheet Board Style Low Water Cutoff

Measurement Systems Datascan Installation and User Guide

+GF+ SIGNET ph/orp Transmitter Instructions

Transcription:

MTD75 Comprehensive cooling tower controller with all the functions required for dosing and control of cooling water Features Real time clock for accurate timed dosing Water meter input for volumetric/proportional dosing Inductive conductivity measurement for bleed control Redox measurement for Bromine addition Independent ph measurement and control Bleed inhibit during and after the dosing cycle Individual fuses for each control relay output IP66 Custom enclosure Full data logging and live trending to SD card

The MTD75 controller The MTD75 is a microprocessor controlled cooling tower controller, designed to provide timed or measured control of dosing pumps or solenoid valves for inhibitor, biocide, bleed and ph control operations in a cooling tower system. The efficiency of the MTD75 to control the cooling water can be greatly increased by using sensors to control the dosing and bleeding of the water instead of just relying on fixed time and water meter controls. The unit can be optionally equipped to measure Conductivity, ph, Redox and Temperature levels in the cooling tower. 2

The MTD75 controller is designed for fixing to a wall or other flat surface. There is an optional handrail & pipe-mounting kit is designed for fixing to a vertical or horizontal handrail or pipe, of 25 to 70mm outside diameter. The MTD75 is designed to be expandable by the use of add-in cards; these add-in cards can take the form of either sensor input add-in cards or output option add-in cards. The MTD75 can be fitted with up to 3 sensor input cards and 1 output option card. Utilising a multifunction easy to read QVGA LCD the controller displays readings and provides feedback to the operator on the status of the sensors and the controller s outputs. Six sets of relay contacts are provided for the pump/solenoid connections and an alarm output. For the Biocide, Inhibitor and Bleed Connections, the pump relay contacts are normally open; volts free contacts, and are isolated from the rest of the controller. The contacts are rated at 250vAC/30vDC @ 5A. In addition to the two relay contacts, the terminals for each of the pumps or solenoids provide connections to the Live and Neutral lines. The Live terminals are fused via the front panel fuses, at 2A. The alarm relay contacts are normally open; volt free contacts, and are isolated form the rest of the instrument. The contacts are rated at 250vAC/30vDC @ 5A. The MTD75 can be supplied with 4 current outputs designated A to D, which can terminate into a load resistance not exceeding 750Ω and can be allocated to the Conductivity, ph, Redox or temperature measurement. There is also an optional RS485 Modbus interface to allow for remote access, configuration and control of the controller and integration with building energy management and SCADA systems. The MTD75 controller also features an SD card interface which enables the user to backup and restore controller settings, copy settings between controllers, and to upgrade the controller s software. The Data logging additional software function expands the capabilities of the MTD75 by allowing the user to record over time the status of the instrument. It consists of two separate sections, Live Trending and SD Card Data Logging, which together help the user to analyse and improve the performance of their application. Live Trending provides the user with three separate live trend screens adjacent to the front screen with each showing two readings. This enables the user to instantly view the last 50 samples of each reading. The live trend screen also features a review mode where by the user can further analyse the last 200 samples of each reading, If the user finds something of note the software provides the facility to save these 200 readings to an excel compatible file on the SD card. The MTD75 features optional software functions which when purchased will expand the instrument s capabilities. These functions are locked by default. They can www.lth.co.uk be unlocked by LTH or your local distributor at the time of order. Alternatively the functions may be ordered after purchase by supplying LTH or your local distributor the serial number of your instrument. In return they will supply you with an 8 digit unlock code that is unique to the instrument and the required function to be unlocked. The MTD75 features 5 digital inputs, the instrument can be configured to initiate the appropriate action when the contact either closes or opens between the input terminal and the reference terminal. The terminal marked 1 is provided for contact to a standard water meter where contact activation indicates the flow of water. The K factor for the water meter can be set in the Configuration menu, The terminal marked 2 is provided for connection to a flow switch in the process loop to indicate when there is no water flow past the sensors. When activated this will flag an error message on the main display and inhibit any dosing or bleed relays. The polarity of this input (NO/NC) can be set in the digital input 2 menu. Digital inputs 3 to 5 provide a user configured system to set the associated relay to either Offline or Interlock, to indicate that there is a chemical Tank Level issue, or to activate a remote Dose or Bleed of the relay. The MTD75 can also be supplied as a bespoke Control and dosing package complete with sensors, pipework, valves and pumps on a backplate assembly prefabricated to suit a customer s requirements. Contact our sales department with your requirements. 3

MTD75 Controller Specification Biocide A Output User defined Biocide A dose duration, triggered from one of the user selectable sources: Water Volume (From Water Meter Input), Timed (Per week/day/hour) Redox (when greater than the set level), Division of the Water Meter Input (X input pulses give one output pulse), Multiply by the Water Meter Input (One input pulse gives X output pulses), External Input (Contact Closure) User selectable On/Off, Pulsed or Time Proportional output. Contact closure and 250vAC* supply terminals provided (fused to 2A, accessible on the front panel). The Biocide A output can be initiated manually through the menu system to permit testing and priming of the system. Biocide B Output User defined Biocide B dose duration, triggered from one of the user selectable sources: Water Volume (From Water Meter Input), Timed (Per week/day/hour) Division of the Water Meter Input (X input pulses give one output pulse) Multiply by the Water Meter Input (One input pulse gives X output pulses) Ratio (Biocide A : Biocide B), External Input (Contact Closure). User selectable On/Off, Pulsed or Time Proportional output. Contact closure and 250vAC* supply terminals provided (fused to 2A, accessible on the front panel). The Biocide B output can be initiated manually through the menu system to permit testing and priming of the system. Bleed Output User defined Bleed duration, triggered from one of the user selectable sources: Water Volume (From water Meter Input), Timed (Per week/day/hour) Conductivity (when > set level), External Input (Contact Closure) On/Off output at 250vAC* fused to 2A (accessible on the front panel). The Bleed output can be initiated manually through the menu system to permit testing of the Bleed system. Inhibitor Output User defined Inhibitor dose duration, triggered from one of the user selectable sources: Water Input (From water Meter Input), Timed (Per week/day/hour) Bleed (After accumulated Bleed Time), Division of the Water Meter Input (X input pulses give one output pulse), Multiply by the Water Meter Input (One input pulse gives X output pulses), External Input (Contact Closure) User selectable On/Off or Pulsed output. Contact closure and 250vAC* supply terminals provided (fused to 2A, accessible on the front panel). The Inhibitor output can be initiated manually through the menu system to permit testing and priming of the system. ph Control User defined ph Control dose duration, triggered from one of the user selectable sources: Water Volume (From Water Meter Input), Timed (Per week/day/hour) ph (user selectable < or > level), Division of the Water Meter (X input pulses give one output pulse), Multiply by the Water Meter Input (One input pulse gives X output pulses), External Input (Contact Closure) User selectable On/Off, Pulsed or Time Proportional output. Contact closure and 250vAC* supply terminals provided (fused to 2A, accessible on the front panel). The ph Control output can be initiated manually through the menu system to permit testing and priming of the system. Alarm Relay A volt free normally open contact, rated at 5A 30vDC / 5A 250vAC (non-inductive). User configurable to energise on: Power On Input Error, Dose Alarm Timeout, Water Meter Timeout, Flow Switch Tank Level Alarm, Any Error Redox Input Optional, Single ended or differential with solution ground, Up to 100 metres cable. Separate glass and reference electrode pair. Combination electrode. Range of Measurement: -1999mV to +1999mV, Accuracy ± 3mV Electrodeless Conductivity Input Optional ECS20 or ECS40 Series Electrodeless conductivity sensor up to 100 metres LTH 54E connection cable Range of Measurement 0 to 0-9999µS/cm 0-9999ppm Accuracy: ± 1% of range ph Input Optional, Single ended or differential with solution ground. Up to 100 metres cable. Separate glass and reference electrode pair. Combination electrode. Range of Measurement: 0.00 to 14.00pH. Accuracy ± 0.05pH Temperature Electrodeless Conductivity Input PT1000, ph Input PT100 or PT1000 Range of Measurement: -50 C to +160 C Accuracy ± 0.2 C (When using a 4 wire PT1000) Linearity ± 0.1% of range Repeatability ± 0.1% of range EMC 2004/108/EC using BS EN 61326-1: 2013 Low Voltage Directive 2006/95/EC using BS EN 61010-1: 2010 Power Supply Universal 80-265V AC or DC, 15W max Instrument Housing UL 94-V0 PC/ABS Ingress Protection Rating IP66 Ambient Operating Temperature -20 C to +50 C (-4 F to +122 F) for full specification Weight Maximum 2.7 kilograms (instrument only) Dimensions 331 x 242 x 110 mm (H, W, D) excluding mounting brackets 4

Operator Adjustment Slope Offset Redox NA ± 400mV Electrodeless Conductivity ± 10% NA ph 60-120% 3 to 11pH Temperature NA ± 50 C Current Outputs Optional, 4 Current Outputs, each selectable 0-20mA or 4-20mA into 750 ohms maximum load. Fully isolated to 2Kv. Expandable up to 5% of any operating range and offset anywhere in that range. Current Output Adjustment: ±0.01mA, 3 point 0-4-20 ma for remote monitor calibration Digital Inputs 5 contact closures for remote activation of user defined operations. Can be configured to operate in either normally open or normally closed modes Digital Input Functions: 1. Water Meter Input. 2. Flow Switch Input 3-5. Off-Line, Interlock, Tank Level, Remote Dose Modbus RS485 Interface Optional, Supports RTU and ASCII formats, Node Address: 1 to 247 Baud Rates (Bits Per Second) : 300, 600, 1200, 2400, 4800, 9600, 19200, 31250, 38400. Parity Options: Even, Odd, None. SD Card Interface Enables backing up and restoring of instrument configuration, log the sensor readings (optional extra) and on site upgrading of instrument software. SD, SDHC and SDXC-FAT32 cards supported. Display 3 ¾" QVGA back lit LCD module. Buttons 5 tactile feedback, micro-switched, silicone rubber. 5

IP66 Surface mount enclosure with optional pipe mount kit. 3¾" QVGA Backlit LCD display for clear indication. Parameters measured include: Electrodeless Conductivity, ph, Redox, temperature. Up to 3 measured parameters can be displayed together plus temperature. User selectable bar graph display option. Plug and play card detection for simple measurement and output expansion upgrades. SD card interface allows trouble free saving of configuration and simplifies software updates. SD Card data logging. Three separate live trend screens. 4 Optional isolated 4-20mA current outputs for re-transmission of conductivity, Redox, ph and temperature. Optional RS485 Modbus for integration with external process management and SCADA systems. Dosing relays are fully configurable including on/off, time or pulse proportional operation. 5 Independent digital inputs. Direct connection of pumps and valves. Dedicated error page provides up to date controller status. 85-265v supply (AC or DC). User configurable measurement channel identification tag. Bespoke Control and dosing packages with controller, sensors, pipework, valves and pumps prefabricated to suit customer s requirements can be supplied. 6

A closer look Alarm LED s 2 Yellow LED s located above the main display area for the controller s alarm status, Relays are active when the LED s are lit. Dosing and Control Relay LED s 6 Red LED s located above the main display area indicate the status of the dosing and control relays, Relays are active when the LED s are lit. Ambient Operating Temperature -20 C to +50 C (-4 F to +122 F) for full specification EMC 2004/108/EC using BS EN 61326-1: 2013, Low Voltage Directive 2006/95/EC using BS EN 61010-1: 2010 Controller Housing UL 94-V0 PC/ABS. Ingress Protection IP66 to IEC 60529 Weight Maximum 2.7 kilograms (controller only). Dimensions 331 x 242 x 117 mm (H, W, D) excluding mounting brackets. Power Supply Universal 80-265v AC or DC, 15W max (fused to 1A, accessible on the front panel) * Dependant on input supply levels 7

LTH Electronics Ltd, Chaul End Lane, Luton, Bedfordshire. LU4 8EZ England Telephone: +44 (0)1582 593693 Fax: +44 (0)1582 598036 email: sales@lth.co.uk web: www.lth.co.uk www.lth.co.uk Order Codes Type Stock No Description MTD75 7510 IP66 Surface mounted cooling tower monitor with outputs for Bleed, Biocide A & B and Inhibitor. 85-265v supply. Input and output expansion cards to be ordered separately Input Card Options (To be ordered separately from MXD73 and MXD75 chassis) MXD70EC 1201 Electrodeless conductivity input PCB. MXD70PR 2001 ph / ORP (Redox) input PCB. Expansion Card Options (To be ordered separately from MXD73 and MXD75 chassis) MXD704I 7040 4 x 4-20mA output expansion PCB for use with the MTD75 Cooling tower monitor. Modbus 7520 MTD75 Modbus Unlock code Data Logging and Live Trending DATALOG 7000 Data logging and Live trending software (Unlock code) Expansion Kits for use with MXD75 Surface Mount chassis MTD75EK1 7511 MTD75 Expansion kit 1 for use with Electrodeless Conductivity and Redox Input PCB s. MTD75EK2 7512 MTD75 Expansion kit 2 for use with the ph Input PCB and current output PCB. Sensors ECS20 Series Electrodeless Conductivity Sensors Temperatures Up to 60 C, manufactured from Glass filled polypropylene, fitted with PT1000 temperature compensation Type Stock No Description ECS20T 8480 Moulded Electrodeless conductivity sensor with 5 metre cable. ECS22T 8481 600 mm PVC dip assembly with ECS20T sensor. ECS24T 8489 In-line 1.5" plain PVC tee assembly with ECS20T sensor ECS24T 8490 As 8489 but with 0.5" BSP galvanised connections S400 ph and Redox Electrodes Type Stock No Description S400 138/028 0.75 NPT insertion ph electrode, no temperature compensation, 6 metre cable. S400-RT330-M20FF S400 138/064 0.75 NPT insertion Redox electrode with guarded bulb. 6 metre cable and solution ground. S400-GTPB0-N20FF Tee 2140 S400 1.5" Quick release PVC tee assembly. 0-60 C Please contact our sales team to discuss any bespoke dosing and control packages required. These products comply with current European Directives LTH Electronics Ltd reserves the right to make changes to this data sheet or the product without notice, as part of our policy of continued developments and improvements. All care has been taken to ensure the accuracy of information contained in this data sheet. However we cannot accept responsibility for any errors or damages resulting from errors or inaccuracies of information contained herein. Issue: BON (6718) 07.14