APP 700 Technical Specification

Similar documents
Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

GCU401. Technical specification

ATU800. Technical specification

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

Neon pr. ph/ ORP measurement. Applications. Description

General information. Display. Supply voltage. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information. Display. Supply voltage

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

TALON Network Manager- 2 & 6 Express

MCX08M2 Programmable controller

mark150s mark150/485s DDC controllers Summary

Millenium 3 logic controllers

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).

DS BAS /99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER FEATURES

IQ21x Series Controllers

02/11/2015

SM100. On-Line Switchgear Condition Monitoring

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

VIDI System Controller

Evo2. Free programmable room controller. Summary

PIGEON RB100-CM3. Features. Applications

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

IMIO100 IMIO105. DDC controllers. Summary

NX21 USER MANUAL. Telemetry Unit. Version 1.5

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

PTU300 Combined Pressure, Humidity and Temperature Transmitter

POL635.XX/XXX POL636.XX/XXX POL638.XX/XXX POL638.70/XXX

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

CPU 1214C. Overview. Design. The compact CPU 1214C has:

MIC-2 MKII, Multi-instrument DATA SHEET

FX06 Field Controller

DATA SHEET Advanced Graphical Interface, AGI 300 series

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

DC561, digital input/output module,

Industrial Control SE-607

2 Device description. 2 Device description 2.1 Function. 2.1 Function. 2.2 Intended use. 2.3 Device versions

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Programmable Relay ZEN V2 Units

Power Panel. Terminal block, 12 pin, 20 pcs., cage clamps. Table 5: Order data for PP41

DATA SHEET Advanced Graphical Interface, AGI 100 series

MM-IM. Large works automation And data gateway. PRODUCT DATASHEET

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Power Meter PowerMonitor 500

DX561 Digital Input/Output Module

RIC PROGRAMMABLE INTELLIGENT CONTROLLER

Technical specification Marine Master Clock

LAUREL ELECTRONICS, INC.

EP/2 Installation Instructions

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

DC562, digital input/output module,

DI561 Digital Input Module

CAEL-DP Series Dew Point Transmitter for Industrial Control

Comprehensive Modular Genset Controller

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

AO523 Analog Input Module

TM241C40U controller M IO transistor NPN

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

MIC-2 Multi-instrument DATA SHEET

CONTROL MICROSYSTEMS and 5404 Digital Input Module. Hardware Manual

Energy Management BUS Adapter Type VMU-B

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

TM241C24T controller M IO transistor PNP

DS BAS 08/99 UNC 532

Energy Management BUS Adapter Type VMU-B 01

F1000 User's Manual. (Version: V1.01)

AI561 Analog Input Module

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

TU531, TU532 Terminal Unit

Industrial Power Supplies

the easy solution for Smart Metering

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

Transcription:

Issued: 12/12 Supersedes: 4/12 Description The APP 700 hardware series are especially designed for waste and clean water systems, both in construction and functionality. The RTUs¹ are developed to meet the demands of powerful flexible monitoring and control units and are prepared to work with various types of communication e.g. SCADA system, radio, ethernet cellular systems, dedicated and dialed-up telephone lines. The RTUs complies with the required electromagnetic emission and immunity standards. The front panel is user-friendly with self-instructive symbols. The RTUs are easy to install and commission. Part Number Front mounted 40 501645 APP 721 2-Pump Controller 40 501646 APP 731 3-Pump Controller 40 501647 APP 741 4-Pump Controller Approved standards EMC emission standard EN 61000-6-4 EMC immunity standard EN 61 000-6-2 LVD EN 60947-1 CSA C22.2 No. 14-95 UL Recognized File Number E302902 Environment Operational temperature Storage temperature Humidity (non-condensing) -4 - +122 F -14 - +149 F 90 % RH Frontal mounting Front panel; front side IP 65 Front panel; backside IP 20 I/O unit IP 20 Frontal unit Size (L x W x H) Weight, total Mounting Surface seal Connectors 11.30x7.36x1.73 in 3.97 lb I/O unit Size (L x W x H) 11.65x10.67x2.44 in Weight, total 4.41 lb Mounting Wall Connectors 1 DB 37 Wire terminals 68, screw locked Cable Front panel to I/O unit Length Minimum bend radius Double shielded 37pole 6.56 ft 1.97 in Data Processing power Processor Elan SC520 (486) Executed word length, protected mode 32 bits Clock frequency 100 MHz Primary memory 16 Mbytes, D-RAM Secondary memory 16 Mbytes, flashdrive Battery backup Li, 3 V replaceble Watchdog Yes Character set The RTU is capable of handling Unicode characters however, the standard display can only show a limited set of characters. A special version is available for Simplified Chinese characters. Expandable system The possible number of inputs and outputs can be expanded to 600 when external RIO modules are connected. The RTU communicates with the RIO modules on a SIO field bus and an optional SIO driver is mounted in the RTU to run the SIO bus. ¹ Remote Terminal Unit

Communication The RTUs series is equipped with serial communication ports for local PC connection and modems. Accessories Standard software. Level sensor. Modem. Power supply. Over voltage protection. SIO driver. RIO modules. Overlays.

Technical data APP 721 Pump Controller APP 731 Pump Controller APP 741 Pump Controller Digital inputs All in puts are individually opto-isolated Locic 0: -3 -+5V Locic: 1: 11-30 V, 6-30 ma 16 16 16 Digital outputs All outputs are individually isolated 8 8 8 Relay Outputs: 6 Type: Normally open, unprotected Max load: 2 A 250 VAC/DC Solid State Outputs: 2 Type: Normally open, unprotected Output: 100 ma, 250 VAC/DC Leakage current max: 0,01 ma Analogue inputs All inputs are individually opto-isolated Resolution: 12 bits Signal range: 4-20 ma Internal dynamic resistance, full scale: 50 Ohm Inaccuracy, full scale, typ.: 0.1% Voltage drop: 8V 4 4 4 Communication Communication port: Bus communication: Optional SIO Driver Max number of I/O: 4 4 4 600 600 600 User interface Display: LCD 2x20 character, LED backlight Push buttons: Alarm indications: LEDs Pump well indications: LEDs RTU status indications: LEDs 8 8 8 16 16 16 7 10 13 4 4 4 Power supply Supply voltage: 24 VDC -15% - + 20% Current consumption (no load): 1 A Fuse: 2A Digitals inputs, max load: 0,5 A Analogue inputs, max load: 24 V, 80 ma = included

Interface Functions COM1 COM2 COM3 COM4 Dialled-up connection GSM modem Dialled-up connection external modem Radio communication, polled system Dedicated line modem Dedicated line 232/RS485 converter Service Ethernet adapter

Logical 0 = -3 to +5V Voltage drop = 8V Relay outputs Semiconductor outputs Logical 1 = 11-30V, 6-30mA 4-20mA 2A 250V AC/DC 100mA 250V AC/DC DIGITAL INPUTS ANALOGUE INPUTS DIGITAL OUTPUTS + + + + + + + + + + + + + + + + + + + + + + + 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 - - - - - - - - - - - - - - - - - - - - - - - 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52

11.65 in 10.87 in 2.14 in APP/AP Front Front mounted mounted I/O Unit I/O Unit 9.50 in 10.87 in 11.65 in 1.73 in 5.85 in 11.30 in 10.08 in APP/AP Front Front mounted Operator panel panel 6.90 in 5.45 in 10.83 in