Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Similar documents
Single Door Standalone Access Control User Manual

CM-110SK Standalone Keypad Installation Instructions

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Digital Keypad Introduction

Waterproof. Keypad/Reader/Controller

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Stand-alone Proximity Access Control

Fingerprint Access Control F1. User Manual

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

W3-H Waterproof Keypad/Reader/Controller

HSY-S209 EM Metal waterproof access control system User Manual

User Manual. Split access control with intelligent secured power supply.

Installation and User Manual

EL-ST100 KEYPAD CONTROLLER

VIDI-AC-2CS Access Controller/ Reader

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

W3-M. Metal waterproof standalone access control/reader. User Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual

DOLXFD1000B. Waterproof Access Control/Reader

-DTZ001- Stand-Alone Proximity Access Control. User Manual

VIS-3200 / VIS-3201 User Manual

BC Digital Keypad. User Manual

User Manual. PCKeypad Wireless Keypad

RBR-SB-KTZ001 LAR 2. User Manual

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

CC Series metal access control Manual

Installing Keypad and Backplate

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

CM-500 SK 500 USER CODES KEYPAD

Specifications: Features:

CV-945 Stand-Alone Biometric Reader. Installation Instructions

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

1. Product Specification

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

REX F-0-9 Standalone or Access Controller

GV-Card Reader. User s Manual

AS Keypad User Manual

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

DG Series. Access Control Proximity Readers DG-160 DG-800

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

RFID/Digital Access Control Keypad

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

DT-AKP 2 WIRE SYSTEM. User Manual. Access keypad panel with scramble keypad DT-ENG-AKP-V1 /

Fast operation of IP Villa System V 1.0

Access control panel U-Prox IC E (Elevator control)

Users Manual. Operating and Installation Instructions Buffalo River Black Dimaond. Model:ECSL-0601A Electronic Combination Controller

Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader

GV-RK1352 and GV-R1352 Card Reader

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

GENERAL QUICK START GUIDE

GV-AS Controller. Installation Guide

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

Fingerprint Identification Proximity Reader. Quick Installation Guide

4 Wire Video Intercom System

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

Outdoor Stand-Alone Weatherproof Keypads

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

CP150B Vandal & Weather Resistant Keypad Security Systems

Operation manual For NG BIOSINGLE Version 1.1

FTK5 PROXIMITY KEYPAD

WELCOME. For customer support or any inquiries, please visit our web site at or contact us at

Set-up of ZK RFID Pin Pad

Wireless Digital Video Doorbell

Quick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER

Quick Start Guide. GV-CS1320 Camera Access Controller

SVT-WIFI Video Intercom System C

B100-SA Standalone Biometric Reader

Revision Date: 02 Mar 2018

GV-EL124S Electric Strike

Wireless Key fob, Key pad & Receiver Range

SK-3133-PPQ Heavy-Duty Outdoor Access Control Keypad with Proximity Reader

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

Standalone Access Control

GV-AS/EV Controller. User s Manual

3001D Smart Safe Manual

Wiring Instructions v3

XP-KIT. Programming & Operations. Programming Starter Kit for Aiphone -XP Series Proximity Reader Stations

Enter a new user. code. Enter. Enter a 2-digit user ID. Enter a user code. (from 00~09) (from 00~09) Enter

K44 Code lock. Technical manual

SYRIS SY110SA. Operating Manual. Ver:1.60

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

Fingerprint Access Standalone User s Manual

2-Wire Video Outdoor Station

E-Access ANXELL TECHNOLOGY CORPORATION E3AK4 E3AK2. Specifications Voltage (Input): 12 to 24 VDC

AC-015 Single-Door Access Control Programmer Hardware Installation and Programming Manual

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

Transcription:

Instruction Manual DH16A-60DTE Model 60 with plastic keypad, stand alone access control DH16A-60DTQE Model 60 with plastic keypad, networked access control 2013-V01 Security Technology Vogue Innovation

Add the card in group Press the button and.the yellow LED indicator will be flashing, then press and 1, a sound Bi as reminder. Then input three-figure( 000-999 any position express will add the card from this position, for example input 050 means it will add the card from 50 ), then input three-figure number means the number you want to add ( for example add 50 pcs of cards input 050, if add 150 pcs of cards input 150), after adding cards, a sound Bi as reminder. Swipe the first added card or input the first added card 8 digits serial number, a sound Bi as reminder, means added in successfully. Press to quit setting mode. Modify the user code Enter to the setting mode firste: Press the button and ( the yellow indicator will be flashing ), then press the button and 2, input 3 digits position number ( any digits between 000-999 ), then input the code: X X... ( the length of the password should be same as admin code ), and a sound Bi as a reminder, means password setting successfully. Press to quite the setting mode. Setting access control ID (for networked) Press the button and ( the yellow LED indicator will be flashing), then press the button and 3 ( a sound Bi as reminder), then input 6 digits ID number ( a sound Bi as reminder ), means ID setting successfully. Press to quite the setting mode. -9-

Modify administrator mode Press the button and ( the yellow LED indicator will flashing ), then input a new administrator code twice ( the length of the new admin code must as same as the old one ) and a sounds Bi means modify successfully. Add the master card Press the button and : 1. The mode indicator flash green, it indicates there is no master card stored, swipe the card, a sounds Bi means add the master card successfully. 2. The mode indicator turn green, it indicates there is already data existed, press the button twice to clean up the data, and then the indicator will flash green, ( it can add the master card directly ), swipe the card, a sounds Bi means add the master card successfully. Using the master card enter the setting mode Swipe the master card, the indicator will flash yellow whilst a 'Bi' will be heard, enter the setting mode, and can do the each setting, swipe the card again, rapid beep sound will be heard, Exit the setting mode, the power indicator will turn green. The access control will be locked for 60s if the mistaken code continuously input or swipe the invalid card for 5 times ( both the keypad and card swiping are not available during the 60 second ) Detect the door status: when someone opens the door and comes in,the door is closed, the system will automatically detect the door status and lock the door even though it is still in delay period. Notice: The enter code must be different with the admin code. DH16A-60DTE DH16A-60DTQE NO. description status indicator keypad inductor screw Operating environment: environment temperature:-20 ~+50 Environment relative humidity : 95% Operating voltage/current: input DC:+12V +15V input AC:12V~15V standby current: 80mA work current: 110mA Application card: ID card (default) T5557card/T5567card(required setting) Inductor distance: 5cm Capacity : 1000 ID cards and 1000 sets of code Specifications / Features 1. Build-in EM reader. 2. Frequency:125KHz. 3. Inductor distance 5cm. 4. Capacity: 1000 ID cards and 1000 sets of code to unlock the door. 5.Card access, code access or combined access. 6.Keypad operation. 7.Alarm for light detecting if tearing open. 8.Watchdog recovery, power reset. Can connect to external unlock button. 9.Unlock delay time:0-99seconds. 10.IP degree:65. 11. Dimension:120*76*22mm. 12. Unlock door methods:card/code/card plus code,and unlock button. It can detect door status. -8- -1-

Installation Before installation, position the location where the access control is mounted. Operation according to the following steps: 1. Use specialized tool to open the access control and remove the back cover. 2. Locate the provided drilling template accurately. The drilling holes is marked as B. Drill four holes according to the location of B. 3. Use the screws provided to mount the back case on the wall. Pull the wire through the central hole and keep the back case level. 4. Connected the wire according to the wiring diagram on the back. 5. After the connection of the access control, use screws to fasten the access control with the back case. screws Delete all user card and codes, restores to factory defaults Press the butting and (yellow indicator will flash yellow), then press the button twice (a continuous Bi will be heard, and the indicator will turn yellow) means delete all the card and code successfully, all the setting card and code are invalid. Press the button and (yellow indicator flashing), press the button twice ( Bi sounds, indicator turn yellow), it indicates it restores to factory defaults successfully, all the setting restored to the factory status. If entered the wrong information, Bi Bi sounds, In the setting mode, the device will turn back without any operations in 30 seconds, and Bi Bi will sounds.if not in the setting mode, the device will turn back if the button press is not finished in 5 second, and the Bi Bi sounds. Under the mode of open the door using the card and the code, operated either method and not finished another one, the device will turn back in 5 second and the Bi Bi sounds. Door open indicator When the door electrical relay works, the indicator will turn green. system wiring screw anchors In case forget the admin code, press the and hold on, and then power on, Bi sounds, means modify the admin code successfully, if the digit length is 2 the admin code is 12, and so on, the maxmium length of the digits is 6. The pickproof alarm the built-in buzzer will send a continuous beeping if the photoresistor sensor is directly exposed into the light. The buzzer will be off automatically in 60 seconds when the light is no longer detected, or by entering the admin code. -2- -7-

Add card and password to unlock Enter any number from 000-999 ( Yellow light flashes. If red light is on, it indicates the number stores card / code. Press twice to clear the card/code. Then, add new card and code. If green light is on, it indicates the number does not store card/code. Card and code can be stored to this number). Then, swipe a card ( Bi sound indicates the card is added successfully). Enter code XX...(code is set according to the code digit setting). Bi sound heard indicates the code is added successfully. Delete card and code for unlock function Enter any number between 000-999. If red light is on, it indicates the number stores card and code. Press twice to clear the card and code in the number. Wiring diagram (stand alone) Red - power DC input: +12V +15V Black - power AC input: 12V~15V Brown - NO Blue - COM Yellow - NC Green - GND Purple - unlock button White - door status detecting Change the relay unlock time Press the button and (the yellow indicator flashing), input any two digits number between 00-99 ( Bi sounds, the yellow indicator stoped flashing ) means the unlocking time, for example 05 means setting the relay unlock time in 5 seconds, but if setting 00 it means swipe card or input the password once as open the door, swipe the card or password again as close the door. Turn on / off the pickproof alarm Press the button and (mode indicator will flash yellow), follow with the and (a beep will be heard and the yellow indicator stop flashing), pickproof alarm is turned off. Press the button and ( mode indicator will flash yellow), follow with the and (a beep will be heard and the yellow indicator stop flashing), pickproof alarm is turned on. Red Black Brown Blue Yellow Green Purple White NO COM NC Applicable for: DH16A-60DTE DC input: +12V +15V AC input: 12V~15V Pay attention for right polar connection power adapter Door lock GND Button Door magnet -6- -3-

Wiring diagram (networked) Red Black Brown Blue Yellow Green Purple White Orange Gray Red - power DC input: +12V +15V Black - power AC input: 12V~15V Brown - NO Blue - COM Yellow - NC Green - GND Purple - unlock button White - door status detecting Orange - 485- Gray - 485+ NO COM NC 485+ -4- -5-485- DC input: +12V +15V AC input: 12V~15V Pay attention for right polar connection power adapter Door lock GND Button Door magnet Operation instruction 1. Store 1000 cards and relative codes, use card/code,card and code to unlock door 2. Default management code is 1234 3. Steps to enter to the setting mode: Press management code twice ( 1234&1234. If the code is set as 2-digit code, the default code changes to 12. Code can be set as 2-6 digits. If the code is set as 6-digit, the default code is 123456 ), and then it is in the setting mode. The yellow light is on. Unlock door by card/code a. Press (yellow indicator light flashes), then press (BI sound. Yellow indicator light stops flashing ). It is set as using card to unlock door only. b. Press (yellow indicator light flashes), then press (BI sound. Yellow indicator light stops flashing). It is set as using card or code to unlock door. c. Press (yellow indicator light flashes), then press (BI sound. Yellow indicator light stops flashing ). It is set as using card & code to unlock door. Set the code digit Press (yellow indicator light flashes), then press 4 ( BI sound ). Enter the code digit X (X=2,3,4,5,6. 2 indicates 2-digit code, 3 indicates 3-digit code...). Bi sound heard indicates the setting is successful. If heard three quick BI sound, it indicates the new code digit is the same as the previous. There is no change implemented. Applicable for: DH16A-60DTQE NOTICE: If the code digit is changed successfully, all the cards and codes stored are cleared.