PE310G4BPI9 Bypass Card Quad Port Fiber 10 Gigabit Ethernet Bypass Server Adapter Intel 82599ES Based

Similar documents
PE310G4BPI40-T Bypass Adapter Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel x540 Based

PE210G2SPi9A Dual Port Fiber 10 Gigabit Ethernet PCI Express Server Adapter Intel based. Description. Key Features

PE2G6BPi35 Six Port Copper Gigabit Ethernet PCI Express Bypass Server Adapter Intel based

PE310G4SPI9LA Quad Port Fiber 10 Gigabit Ethernet PCI Express Server Adapter Intel 82599ES Based

PE310G4DBi9 Quad port Fiber 10 Gigabit Ethernet PCI Express Content Director Server Adapter Intel based

PE2G6SFPI35 Six Port SFP Gigabit Ethernet PCI Express Server Adapter Intel i350am4 Based

PE2G4SFPI35L Quad Port SFP Gigabit Ethernet PCI Express Server Adapter Intel i350am4 Based

PE2G4SFPI80 Quad Port SFP Gigabit Ethernet PCI Express Server Adapter Intel 82580EB Based

PE310G4I71L Quad Port Fiber SFP+ 10 Gigabit Ethernet PCI Express Server Adapter Intel FTXL710BM1 Based

PE3G4TSFI35P Quad Port Fiber Gigabit Ethernet PCI Express Time Stamp Server Adapter Intel Based

PE310G4I71L Server Adapter Quad Port Fiber SFP+ 10 Gigabit Ethernet PCI Express Server Adapter Intel FTXL710BM1 Based

PE310G4SPI9 Quad Port Fiber 10 Gigabit Ethernet PCI Express Server Adapter Intel 82599ES Based

PE310G4TSF4I71 Quad Port SFP+ 10 Gigabit Ethernet PCI Express Time Stamp Server Adapter Intel Based

PE2G6I35 Six Port Copper Gigabit Ethernet PCI Express Server Adapter Intel i350am2 Based

PE340G2BPI71 Dual Port Fiber 40 Gigabit Ethernet PCI Express Bypass Server Adapter Intel XL710 Based

PE310G2SPT10 Dual Port SFP+ 10 Gigabit Ethernet PCI Express Server Adapter Broadcom BCM57810S Based

PE2G4B19L Quad Port Copper Gigabit Ethernet PCI Express Server Adapter Broadcom BCM5719 Based

SCPE340G1Qi71 Fiber 40 Gigabit Ethernet PCI Express Server Adapter

SCPE340G2Qi71 Fiber 40 Gigabit Ethernet PCI Express Server Adapter

OE2G2I35 Dual Port Copper Gigabit Ethernet OCP Mezzanine Adapter Intel I350BT2 Based

PE340G2DBIR Dual Port Fiber 40 Gigabit Ethernet PCI Express Content Director Bypass Server Adapter Intel FM10420 Based

M1E340G2Qi71 Fiber (SR4) 40 Gigabit Ethernet PCI Express Module Server Adapter

Dual Port Fiber 100 Gigabit Ethernet PCI Express Content Director Bypass Server Adapter Intel FM10420 Based

PE31640G4QI71 Server Adapter Quad Port Fiber 40G Ethernet PCI Express Server Adapter Intel XL710 Based

PE210G2P316 Dual Port 10 Gigabit Ethernet PCI Express Packet Processor Server Adapter

PE2G2FI35 Dual Port Fiber Gigabit Ethernet PCI Express Server Adapter Intel i350am2 Based

OE310G4I71 Quad Port SFP+ 10 Gigabit Ethernet OCP Mezzanine Card Intel XL710 Based

Symantec S500 Network Interface Card Options and Installation

Symantec S500 Network Interface Card Options and Installation

IS100 Silicom 100G Intelligent Bypass Switch

ExtremeSwitching TM. 100Gb Ethernet QSFP28 Transceivers and Cables. Product Overview. Data Sheet. Highlights. 100Gb Ethernet QSFP28 SR4 MMF

LREC9030PF PCIe x1 100FX Desktop Fiber Ethernet Adapter (Intel Based)

ProCurve Switch 1400 Series

PXG2F Dual Port Fiber Gigabit Ethernet PCI-X Server Adapter Broadcom Based

Cisco Series Gigabit Ethernet Half-Height Line Card

M1E310G6I71 Six Ports Fiber SFP+ 10 Gigabit Ethernet Express Module Server Adapter Intel based

Features and Benefits. Certifications

PLUSOPTIC NIC-PCIE-2SFP+-V2-PLU

A-GEAR 10Gigabit Ethernet Server Adapter X520 2xSFP+

HP G Switch HP G-2SFP Switch HP G-2SFP+ 10G Uplink Switch HP G-PoE+ (124W) Switch

QuickSpecs. HPE OfficeConnect 1420 Switch Series. Overview. Models. Key features

PHYSICAL INTERFACES 5406R

Stride SE2 Series Unmanaged Industrial Ethernet Switches and Media Converters

Features and Benefits. Certifications

Retired. IEEE 802.1p prioritization: delivers data to devices by honoring the priority and type of traffic

Models HP G Switch

Data Sheet FUJITSU PLAN EP Intel X710-DA2 2x10GbE SFP+

Features and Benefits. Certifications

PE2G4BPI80L Quad Port Copper Gigabit Ethernet PCI Express Gen 2.0 Bypass Server Adapter Intel Based

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

PCI Express 10 Gigabit Ethernet Fiber Network Card w/ Open SFP+ - PCIe x4 10Gb NIC SFP+ Adapter

Product Specification NIC-1G-2PF. A-GEAR PRO Gigabit PF Dual Post Server Adapter NIC-1G-2PF. datasheet A-GEAR World Wide Manufacturing

PCI-E Dual / Single Port 10 Gigabit Ethernet Adapter

QuickSpecs. Models HP G Switch

ESW500 Series. Industrial Managed Ethernet Switches

QuickSpecs. Models. Features and Benefits Connectivity. HP V2124 Switch. HP V2124 Switch. Overview

HP G Switch HP G-2SFP Switch HP G-2SFP+ 10G Uplink Switch HP G-PoE+ (124W) Switch HPE OfficeConnect G Switch

Features and Benefits. Certifications

EDS-G205-1GTXSFP/G308 Series

MESR321. Vlinx Isolated Industrial Modbus Ethernet to Serial Gateway B&B ELECTRONICS PRODUCT INFORMATION

Cisco CRS 2-Port 40GE LAN/OTN Interface Module

Preface. To get the most out of this manual, you should have an understanding of Ethernet networking concepts. In this manual, you will find:

ProCurve Switch 1400 Series

PCI Express x8 Quad Port 10Gigabit Server Adapter (Intel XL710 Based)

RuggedNet. RuggedNet GPoE+/Mi KEY FEATURES. Managed Industrial 10/100/1000 Power Source Equipment (PSE) PoE/PoE+ Ethernet Fiber Switch

HP 1700 Switch Series Overview

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

PHOENIX CONTACT - 11/2008

1-Port 10G SFP+ Fiber Optic Network Card - PCIe - Intel Chip - MM

Ha-VIS econ 2000 Fast and Full Gigabit Ethernet Basic. Features

x86 2U 19-inch rackmount computers with 2nd Gen Intel Celeron or Core i7 CPU, 6 Gigabit Ethernet ports, and 2 PCI expansion slots

XE1-P241. XE1-P241 PCI Express PCIe x4 Dual SFP Port Gigabit Server Adapter (Intel I350 Based) Product Highlight

POWERBOX Medline 150 EBM04 Series W Single Output AC/DC Medical Switch Mode Adaptor, Desktop Style

McAfee Network Security Platform

QuickSpecs. Models. Standard Features Server Support. HP Integrity PCI-e 2-port 10GbE Cu Adapter. HP Integrity PCI-e 2-port 10GbE LR Adapter.

HP V1410 Switch Series. Product overview. Key features. Data sheet

NPort 5600 Series. 8 and 16-port RS-232/422/485 rackmount serial device servers. Overview. Serial-to-Ethernet Device Servers

HP V1410 Switch Series Overview. Models HP V G Switch

RuggedMC RMC RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. Ethernet Media Converter (Copper to Fiber) Universal Power Supply Options

Cisco cbr-8 Converged Cable Access Router Supervisor 250G

Models HPE PS G Switch

NOTE: A minimum of 1 gigabyte (1 GB) of server memory is required per each NC510F adapter. HP NC510F PCIe 10 Gigabit Server Adapter

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

NIC-PCIE-4RJ45-PLU PCI Express x4 Quad Port Copper Gigabit Server Adapter (Intel I350 Based)

Quick Start Guide. Physical Description. The Port Status LEDs

RuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter

TM221CE40R controller M IO relay Ethernet

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

ALLNET ALL0141-4SFP+-10G / PCIe 10GB Quad SFP+ Fiber Card Server

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

PCI Express x8 Single Port SFP+ 10 Gigabit Server Adapter (Intel 82599ES Based) Single-Port 10 Gigabit SFP+ Ethernet Server Adapters Provide Ultimate

ProCurve Switch 2510 Series Overview. ProCurve Switch 2510G-48. ProCurve Switch 2510G-24

QuickSpecs. Models HP V1810-8G Switch

Industrial 10G/5G/2.5G/1G/100M Copper to 10GBASE-X SFP+ Media Converter

Feature and Benefits. Certifications

Safety Standards. Model Number:

HARTING econ 3000 Introduction and features

Features and Benefits. Certifications

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

VMIACC-5595 Specification

Transcription:

PE310G4BPI9 Bypass Card Quad Port Fiber 10 Gigabit Ethernet Bypass Server Adapter Intel 82599ES Based Product Description Silicom s quad port fiber 10Gigabit Ethernet Bypass server adapter is a PCI-Express X8 network interface card that contains four 10 Gigabit Ethernet ports on a PCI-E adapter. The Silicom s quad port fiber 10 Gigabit Ethernet Bypass server adapter is targeted to inline network system that maintains network connectivity when system fails. Silicom s quad port fiber 10 Gigabit Ethernet Bypass server adapter supports Normal, Bypass and Disconnect modes. In Normal mode, the ports are independent interfaces. In Bypass mode, all packets received from one port are transmitted to the adjacent port. In Disconnect mode, the adapter simulates switch / rout cable disconnection. Silicom s quad port fiber 10 Gigabit Ethernet Bypass server adapter can Bypass or disconnect its Ethernet ports on a host system failure, power off, or upon software request. In Bypass mode, the connections of the Ethernet ports are disconnected from the system and switched over to the other port to create a crossed connection loop-back between the Ethernet ports. Hence, in bypass mode all packets received from one port are transmitted to the adjacent port and vice versa. This feature enables to bypass a failed system and provides maximum up time for the network. Silicom s quad port fiber 10 Gigabit Ethernet Bypass server adapter includes an on board WDT (Watch Dog Timer) controller. The adapter s software drivers or software application can write commands to the on board WDT controller. The adapter s software drivers, WDT controller and the Bypass circuitry provide an interface that control and manage the mode of the adapter. The Silicom 10 Gigabit Ethernet Bypass server adapters are based on Intel 82599ES Ethernet controllers. 1Page

Key Features Bypass / Disconnect: Bypass / Disconnect Ethernet ports on Power Fail, System Hangs or Software Application Hangs Software programmable Bypass, Disconnect or Normal Mode On Board Watch Dog Timer (WDT) Controller Software programmable time out interval Software Programmable WDT Enable / Disable counter Software programmable Bypass Capability Enable / Disable Software Programmable Disconnect Capability Enable / Disable Software Programmable mode (Bypass, Normal or Disconnect mode) at Power up Software Programmable mode (Bypass, Normal mode) at Power off Independent Bypass operation in every two ports Emulates standard NIC Fiber 10 Gigabit Ethernet 10GBASE-SR: 10 Gigabit Fiber Ethernet port supports 10GBASE-SR (850nM LAN PHY) 10Gigabit 850nM Small form Factor Pluggable (SFP+) Fiber 10 Gigabit Ethernet 10GBASE-LR: 10 Gigabit Fiber Ethernet port supports 10GBASE-LR (1310nM LAN PHY) 10Gigabit 1310nM Small form Factor Pluggable (SFP+) -SRD: Fiber 1/10 Gigabit Ethernet 1000Base-SX / 10GBASE-SR: 10 Gigabit Fiber Ethernet port supports 10GBASE-SR (850nM LAN PHY) 1Gigabit Fiber Ethernet port supports 1000BASE-SX (850nM LAN PHY) 1/10Gigabit 850nM Small form Factor Pluggable (SFP+) -LRD: Fiber 1/10 Gigabit Ethernet 1000Base-LX / 10GBASE-LR: 10 Gigabit Fiber Ethernet port supports 10GBASE-LR (1310nM LAN PHY) 1Gigabit Fiber Ethernet port supports 1000BASE-LX (1310nM LAN PHY) 1/10Gigabit 1310nM Small form Factor Pluggable (SFP+) Fiber 10 Gigabit Ethernet 10GBASE-SR5 (SR 50uM): 10 Gigabit Fiber Ethernet port supports 10GBASE-SR (850nM LAN PHY) 10Gigabit 850nM Small form Factor Pluggable (SFP+) 2Page

Performance Features: IPV4 and IPV6 Supports for IP/ TCP and IP/UDP Receive Checksum offload Fragmented UDP checksum offload for Packet Reassembly CPU utilization- the 82599 supports reduction in CPU utilization, mainly by supporting Receive Side Coalescing (RSC) Support for 16 virtual machine Device Queues (VMDq) per port Support Direct Cache Access (DCA) Advanced memory architecture reduces latency by preceding TSO packets. A TSO packet may be interleaved with other packets going to the wire Minimized number of device I/O interrupts using MSI and MSI-X Offload of TCP / IP / UDP checksum calculation and TCP segmentation Large on chip receive packet buffer (512 KB) Large on chip transmit packet buffer (160KB) Jumbo Frame (up to 16KB) Host Interface: PCI Express X8 lanes Support PCI Express Base Specification 3.0 (8GT/s) Technical Specifications Bypass Specifications WDT Interval (Software Programmable): 3,276,800 msec (3,276.8 Sec): Maximum 100 msec ( 0.1 Sec) : Minimum WDT Interval = (2^wdt_interval_parameter)*(0.1) sec. wdt_interval_parameter: { Valid Range: 0-15} Fiber 10 Gigabit Ethernet Technical Specifications (10GBASE-SR) Adapters: IEEE Standard / Network topology: Fiber Gigabit Ethernet, 1000Base-SX (850nM) Data Transfer Rate: 10.3125GBd Cables and Operating distance: Up to: Multimode fiber: 62.5um, 160MHz/Km 13m* 62.5um, (OM1)200MHz/Km 16.5m * * Defined as half as the distance as specified in the optical transceiver 3Page

Optical Output Power: Normal Mode (Bypass Off): Typical: -2.61 dbm (TX Switch Normal Fiber LC/LC) Minimum: -7.3 dbm Optical Receive Sensitivity: Normal Mode (Bypass Off) Typical: -15 dbm Maximum: -11.1 dbm Insertion Loss: Bypass Mode: Insertion loss (Optical Power attenuation between TX to RX) (LC- fiber- switch- LC) Typical: 0.99 db (From RX to TX) Maximum 1.9 db Fiber 10 Gigabit Ethernet Technical Specifications (10GBASE-LR) Adapters: IEEE Standard / Network topology: Fiber 10Gigabit Ethernet, 10GBASE-LR (1310nM LAN PHY) Data Transfer Rate: 10.3125GBd Cables and Operating distance: Up to: Single-Mode: 5Km at 9um * * Defined as half as the distance as specified in the optical transceiver Optical Output Power: Normal Mode (Bypass Off): Typical: -5.02 dbm (TX Switch Normal Fiber LC/LC) Minimum: -7.3 dbm Optical Receive Sensitivity: Normal Mode (Bypass Off) Typical: -13.9 dbm Maximum: -11.1 dbm Insertion Loss: Bypass Mode: Insertion loss (Optical Power attenuation between TX to RX) (LC- fiber- switch- LC) Typical: 0.69 db (From RX to TX) Maximum 1.6 db SRD: Fiber 1000BASE-SX / 10GBASE-SR Technical Specifications: Optical Output Power (1G): Minimum: -10.9 dbm Optical Receive Sensitivity (1G): Maximum: -15.6 dbm 4Page

Insertion Loss (1G) Maximum: +1.9 dbm Output Transmit Power (10G): Minimum: -7.3 dbm Optical Receive Sensitivity (10G): Maximum: -11 dbm Insertion Loss (10G): Maximum: 1.6 dbm LRD: Fiber 1000BASE-LX / 10GBASE-LR Technical Specifications: Optical Output Power (1G): Minimum: -10.8 dbm m Optical Receive Sensitivity (1G): Maximum: -19 dbm Insertion Loss (1G): Maximum: +0.5dBm Output Transmit Power (10G): Minimum: -5.2dBm Optical Receive Sensitivity (10G): Maximum: 12.6 dbm Insertion Loss (10G): Maximum: +0.5 dbm Fiber Gigabit Ethernet Technical Specifications (10GBASE-SR5) (50uM) Adapters: IEEE Standard / Network topology: Fiber Gigabit Ethernet, 1000Base-SR (850nM) Data Transfer Rate: 10.3125GBd Cables and Operating distance: Up to: Multimode fiber: 50um, 400MHz/Km 33m * 50um, (OM2)500 MHz/Km 41m * 50um, (OM3)2000MHz/Km 150m* *Defined as half as the distance as specified in the optical transceiver Optical Output Power: Normal Mode (Bypass Off): Typical: -2.95 dbm (TX Switch Normal Fiber LC/LC) Minimum: -3 dbm Optical Receive Sensitivity: Normal Mode (Bypass Off) Typical: -14.79 dbm 5Page

Maximum: -11.1dBm Insertion Loss: Bypass Mode: Insertion loss (Optical Power attenuation between TX to RX) (LC- fiber- switch- LC) Maximum 1.9 db Typical: 1.3 db (From RX to TX) Operating Systems Support Windows Linux Operating system support: FreeBSD VMware Hyper-V General Technical Specifications Interface Standard: PCI-Express Base Specification Revision 3.0 (8 GTs) Board Size: Standard height long add-in card 241.3mm X 110.13mm (9.5 X 4.336 ) PCI Express Card Type: X8 Lane PCI Express Voltage: +12V +- 8% PCI Connector: Gold Finger: X8 Lane Controller: Intel 82599ES Holder: Metal Bracket I/O: LC located on internal bracket Weight: 460 gram (16.227 oz) Power Consumption (SR): 17.64 W, 1.47 A at 12V: Typical all ports operate at 10Gb/s, (Normal Mode). 16.8 W, 1.4 A at 12V: Typical Bypass Mode. 16.92 W, 1.41 A at 12V: Typical Disconnect Mode. 17.28 W, 1.44 A at 12V: Typical No link at all ports Power Consumption (SR5): 18.24 W, 1.52 A at 12V: Typical all ports operate at 10Gb/s, (Normal Mode). 17.4 W, 1.45 A at 12V: Typical Bypass Mode. 17.52 W, 1.46 A at 12V: Typical Disconnect Mode. 6Page

18 W, 1.5 A at 12V: Typical No link at all ports Power Consumption (LR): 18.84 W, 1.57 A at 12V: Typical all ports operate at 10Gb/s, (Normal Mode). 16.56 W, 1.38 A at 12V: Typical Bypass Mode. 16.92W, 1.41 A at 12V: Typical Disconnect Mode. 18.24 W1.52 A at 12V: Typical No link at all ports Operating Humidity: 0% 90%, non-condensing Operating Temperature: 0 C 45 C (32 F 113 F) Storage: -40 C 65 C (-40 F 149 F) EMC Certifications: FCC Part 15, Subpart B Class A Conducted Emissions Radiated Emissions CE EN 55022: 1998 Class A Amendments A1: 2000; A2: 2003 Conducted Emissions Radiated Emissions CE EN 55024: 1998 Amendments A1: 2000; A2: 2003 Immunity for ITE Amendment A1: 2001 CE EN 61000-3-2 2000, Class A Harmonic Current Emissions CE EN 61000 3-3 1995, Amendment A1: 2001 Voltage Fluctuations and Flicker CE IEC 6100-4-2: 1995 ESD Air Discharge 8kV. Contact Discharge 4kV. CE IEC 6100-4-3:1995 Radiated Immunity (80-1000Mhz), 3V/m 80% A.M. by 1kHz CE IEC 6100-4-4:1995 EFT/B: Immunity to electrical fast transients 1kV Power Leads, 0.5Kv Signals Leads CE IEC 6100-4-5:1995 Immunity to conductive surges COM Mode; 2kV, Dif. Mode 1kV CE IEC 6100-4-6:1996 Conducted immunity (0.15-80 MHz) 3VRMS 80% A.M. By 1kHz CE IEC 6100-4-11:1994 Voltage Dips and Short Interruptions V reduc >95%, 30% >95% Duration 0.5per, 25per, 250per MTBF*: 33 (Years) ** According to Telcordia SR-332 Issue 2. Environmental condition GB (Ground, Fixed, and 7Page

Controlled). Ambient temperature 40 C LEDs LEDs: (2) LEDs per port Left LED: Link: Turns on link 10G (Blue), Right LED : Act: Blinks on activity (Green) : (1) Bi- color LED per segment (2 ports): Off on Normal Mode Turns on Bypass Mode (Green) / Turns on Disconnect Mode (Yellow) LEDs location: LEDs are located on the PCB, visible via holes in the metal bracket. Each 4 green act and blue 10G link LEDs (2 LEDs per port) are located under their own LC connector port. (Each LC contains 2 ports). The yellow/ green for disconnect and bypass LED is located between the 2 ports in each segment- in the middle under each LC. Connectors: (2) LC Functional Description Silicom s Bypass Server adapters support Normal, Bypass and Disconnect modes. In Normal mode, the ports are independent interfaces (see Figure 1: Normal mode, one Bypass pair is illustrated). Figure 1: Normal Mode Functional Block Diagram 8Page

In Bypass mode, the connections of the Ethernet network ports are Disconnected from the interfaces and switched over to the other port to create a crossed connection loop-back between the Ethernet ports. The connections of the interfaces are left not connected. (See Figure 2: one Bypass pair illustrated) Figure 2: Bypass Mode Functional Block Diagram In Disconnect mode, the transmit connections of the Ethernet network ports are Disconnected from the interfaces. (See Figure 3: one Bypass pair illustrated) Figure 3: Disconnect Mode Functional Block Diagram Silicom Bypass server adapters include an on board Controller that can Bypass the Ethernet ports on host system failure like Power Off, System hangs or software application hangs. The software programmable Watch Dog Timer (WDT) Controller detects a host system fails and it will Bypass automatically the Ethernet ports after programmable time out interval. The WDT Controller can be software programmable enabled or disabled. 9Page

Silicom Bypass server adapters support software programmable to select Bypass or Normal mode. In Normal mode, the ports of the adapters remain independently operational. The drivers of the adapters and the Bypass circuitry provides an interface that control and management the mode of the adapter. The adapter software driver or software application can writes commands to the on board controller. The on board controller processes the commands and activates the bypass circuitry accordingly. After power up the default mode of the adapter is to be in Bypass mode. After driver is loaded, the adapter software driver or application can set the card to a Normal mode. After the Host system issues reset, setting of Bypass controller and circuitry are reserved. Silicom Bypass server adapters support Disable Bypass Capability; hence, if those adapters receive Disable Bypass Capability command, the adapter does not Bypass its Ethernet ports, in this state the four Ethernet ports are independent. The Disable Bypass Capability state is reserved also after power off. This feature enables to emulate a standard NIC. Silicom Bypass server adapters can be set to Bypass or Normal mode at power up. This setting programmable and is reserved also after power off. Order Information P/N Description Notes PE310G4BPI9-SR-SD Quad Port Fiber (SR) 10 Gigabit Ethernet Bypass Server Adapter X8, Based on Intel 82599ES, PCI-E adapter, on board support for Fiber SR, RoHS compliant PE310G4BPI9-LR-SD Quad Port Fiber (LR) 10 Gigabit Ethernet Bypass Server Adapter X8, Based on Intel 82599ES, PCI-E adapter, on board support for Fiber LR, RoHS compliant PE310G4BPI9-SRD-SD Quad Port Fiber (SX/SR) 10 Gigabit Ethernet PCI Express Bypass Server Adapter X8 Gen 3, Based on Intel 82599ES, on board support for Fiber SX/SR, RoHS compliant PE310G4BPI9-LRD-SD Quad Port Fiber (LX/LR) 10 Gigabit Ethernet PCI Express Bypass Server Adapter X8 Gen 3, Based on Intel 82599ES, on board support for Fiber LX/LR, RoHS compliant PE310G4BPI9-SR5-SD Quad Port Fiber (SR- 50 um) 10 Gigabit Ethernet Bypass Server Adapter X8, Based on Intel 82599ES, PCI-E adapter, on board support for Fiber SR (50 um), RoHS compliant 1V4 10Page