VS-P Series. TDK-Lambda INSTRUCTION MANUAL

Similar documents
CUS150M1 Instruction Manual

Instruction Manual. TDK Lambda INSTRUCTION MANUAL

ELV12 Series. Instruction Manual

SWT SERIES. Features. Model naming method SWT Applications. Conformity to RoHS Directive. Product Line up. Triple Output 30W - 100W SWT A-273

Instruction Manual. DANGER Never use this product in locations where flammable gas or ignitable substances are present.

CUS1500M. Instruction Manual

EVS300W/600W Series. Instruction Manual

TDK-Lambda CUS30M Series INSTRUCTION MANUAL

An ISO 9001 Company. HWS , HWS , HWS , HWS , HWS Zero Up Programmable Power Supply

DANGER. Risk of fire, electric shock, and injury. DO NOT insert or drop any object in openings, this could cause unit failure or

Instruction Manual. TDK Lambda. RWS 50B 600B Series INSTRUCTION MANUAL

Basic Characteristics Data

KS15. Output Current Model Output Current Model Output Current Model 5V 1.0A KS A KS A KS V 0.45A KS A KS

Basic Characteristics Data

S8VE (60/90/120/180/240-W Models)

Voltage Current Front-mounting bracket

Basic Characteristics Data

Basic Characteristics Data

Basic Characteristics Data

Switch Mode Power Supply

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

Basic Characteristics Data

Model Number Structure

EFE300 / EFE400 EFE300M / EFE400M

PMT. PMT Panel Mount Power Supply 12V 35W 1 Phase / PMT-12V35W1A. Highlights & Features. Safety Standards. Model Number: General Description

PJ Open Frame Power Supply 24V 50W 1 Phase / PJ-24V50W NA

EFE300 / EFE400 EFE300M / EFE400M

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

GXE600 Series. Instruction Manual

PJ Open Frame Power Supply 12V 100W 1 Phase / PJ-12V100W A

CS SERIES Instruction manual

12-15VDC (12V±5%) 24-28VDC (24V±5%)

CPFE1000F SERIES POWER SUPPLY OPERATION MANUAL

PMT. Model Number: Model Number Input Voltage Range Rated Output Voltage Rated Output Current PMT-12V50W1A Vac 12Vdc 4.17A

3000W Programmable Single Output AEK AEK AEK AEK

Safety Standards. Model Number:

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

PMT. Safety Standards. Model Number:

12-15VDC (12V±5%) 24-28VDC (24V±5%)

PMT. Safety Standards. Model Number:

The power factor of the typical switching power supply is between 0.4 and 0.6.

PMF. Safety Standards. Model Number:

Basic Characteristics Data

PMT. Model Number: CC Code PM 24V 200W 1 A Panel Mount Product Type T Enclosed L L Frame*

PFE-S SERIES Single Output AC-DC Power Module UL / EN60950 Low Voltage Directive CSA C22.2 No Features Model naming method

PJ Open Frame Power Supply 24V 100W 1 Phase / PJ-24V100W A

AC/DC Power Supply Series APPLICATION NOTE

Switch Mode Power Supply S8VT 120/240/480/960 W Models

PJT Highlights & Features

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

PMC. Safety Standards. Model Number:

Switching Power Supply

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

Switching Power Supply

PMC. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-12V060W1NA Vac ( Vdc) 12Vdc 5.

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-12V35W1A Vac 12Vdc 2.92A

Safety Standards. Model Number:

PMC. PMC Panel Mount Power Supply 24V 50W 1 Phase / PMC-24V050W1A. Highlights & Features. Safety Standards. Model Number: General Description

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

ENGINEERING SPECIFICATION SHEET SPEC. Revision History

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 90% at 90V AC)

Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-24V100W1AX Vac ( Vdc) 24Vdc 4.17A

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Basic Characteristics Data

Safety Standards. Model Number:

PMT. Safety Standards. Model Number:

PMT. Safety Standards. Model Number:

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

Table of Contents. 1 General 1.1 Scope

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

Model Number: Model Number Input Voltage Range Rated Output Voltage Rated Output Current PMT-24V100W2AA Vac 24Vdc 4.50A

PMT. Safety Standards. Model Number:

AC/DC Power Supply Series APPLICATION NOTE

Switch Mode Power Supply S8VM (15/30/50/100/150/300/600/1,500-W Models)

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

Universal Power Supplies

CINT W Triple Output Industrial Series

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

SPECIFICATIONS: PSAK650

Basic Characteristics Data

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

PFC Mini TM Power Factor Corrected AC-DC Switchers

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

Model Number Output Voltage Max. O/P Amps Min. O/P Amps 230VAC R&N P-P

ENGINEERING SPECIFICATION SHEET. Table of Contents 1 SCOPE ELECTRICAL SPECIFICATION...5

OPERATING INSTRUCTION

Safety Standards. Model Number: PJB-24V150W A Unit Weight:

Safety Standards. Model Number:

High Speed Remote I/O Module

PRODUCT SPECIFICATION. PC Board Relays. Series.

PMT. PMT Panel Mount Power Supply 5V 50W 1 Phase / PMT-5V50W1A. Highlights & Features. Safety Standards. Model Number: General Description

PMR. PMR Panel Mount Power Supply 4.2V 252W 1 Phase / PMR-4V320WC A. Highlights & Features. Safety Standards. Model Number: General Description

PMH. Safety Standards. Model Number:

SPECIFICATION. For SWITCHING POWER SUPPLY M/N: MPD-F113-V

Product Specification. ML1000 (Medical) Series 100 Watt Power Supplies. Document No Rev

Analog Input Installation Manual

Test Methods for DC/DC Power Modules

Transcription:

VS5P /75P /1P/ 15P Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard. WARNING Do not touch the internal components as they may have high voltage or high temperature. You may get electrical shock or burned. When the unit is operating, keep your hands and face away from it as an accident may injure you. CAUTION This power supply is primarily designed and manufactured to be used and enclosed in other equipment. Do not operate overload or dead short condition for more than 3 seconds. Doing so may cause damage or insulation failure. There is no possibility for fire or burning. Confirm connections to input/output terminals are correct as indicated in the instruction manual. This power supply is PC board type unit. PCB stress such as bending, twisting could cause damage. Therefore, please handle with care. When handling, hold the board edge and take care not to touch component side. When mounting power supply unit on apparatus or equipment, lift the power supply with spacer. Do not drop or apply shock to power supply unit. Avoid places where the products are subjected to penetration of liquid, foreign substance, or corrosive gas. Since the output voltages of VS1P and VS15P are regarded as dangerous energy level (output voltage: more than 2V, output power: more than 2VA), this should not be accessible to end-user. The unit incorporating this product must be protected so that service engineer itself or the tool, which fell at the time of repair, may not accidentally contact the output terminal of this product. This power supply has a possibility that hazardous voltage may occur in output terminal depending on failure mode. The outputs of these products must be earthed in the end use equipment to maintain SELV. If the outputs are not earthed, they must be considered hazardous and must not be made user accessible. Note: CE MARKING CE Marking, when applied to a product covered by this handbook, indicates compliance with the low voltage directive. A219-4-1B

1. Explanation VS5P VS75P VS1P VS15P 1 L: AC input terminal (pin 1 of CN1) Live line(fuse in line) 2 N: AC input terminal (pin 3of CN1) Neutral line 3 FG: Input terminal FG (pin 5 of CN1) Safety earth (Frame Ground) Connect to safety ground of apparatus or equipment. 4 FG: Frame Ground (Connected to pin 5 of CN1) Must be connected to electrically safety ground of apparatus or equipment by electrically conductive spacers. The mounting surface of the spacer should be within MAX φ6mm. 5 + : + terminal 6 -: - terminal 7 V.ADJ: voltage adjust trimmer. The output voltage increases when a trimmer is turned clockwise. 1

2. Connection Method Pay attention to the input wiring. If it is connected with VAC or other wrong terminal, the power supply will be damaged. Input must be off when making connection. Connect FG terminal to ground terminal of the equipment. current of each terminal pin must be less than 5A. The output load line and input line shall be separated and twisted to improve noise sensitivity. In connecting or removing connector, do not apply stress to PCB. Use the input/output connector specified in outline drawing. Also, use recommended crimping tool. Connector is not included with this product. VS5P VS75P VS1P 2

VS15P * VS-P series Input & Connector (J.S.T) VS5P VS75P Connector Housing Pin Connector Housing Pin Input: CN1 B3P-5-VH VHR-5N SVH-21T-P1.1 B3P-5-VH VHR-5N SVH-21T-P1.1 : CN51 B4P-VH VHR-4N SVH-21T-P1.1 B6P-VH VHR-6N SVH-21T-P1.1 VS1P VS15P Connector Housing Pin Connector Housing Pin Input: CN1 B3P-5-VH VHR-5N SVH-21T-P1.1 B3P-5-VH VHR-5N SVH-21T-P1.1 : CN51 B8P-VH VHR-8N SVH-21T-P1.1 B6P-VH VHR-6N SVH-21T-P1.1 CN52 - - - B7P-VH VHR-7N SVH-21T-P1.1 CN52 is used only for VS15P Hand Crimping Tool : YC-16R (J.S.T) 3

3. Explanation of Functions and Precautions 3-1. Input Voltage Range Input voltage range is single phase 85 ~ 132VAC (47 ~ 4Hz) or 11 ~ 175VDC. Input voltage, which is out of specification, may cause unit damage. Rated input voltage range when applying for various safety specs (UL,CSA,EN) will be 1 ~ 1VAC (5/6Hz). 3-2. Voltage Range voltage can be adjusted within the rated range by V.ADJ trimmer (VR51) located near the output connector. voltage range is within ±1% of rated output voltage. By turning the trimmer clockwise, the output voltage can be increased. Please be careful not to increase output voltage excessively as over voltage protection ( OVP ) function might be activated. 3-3. Inrush Current This series has built-in Inrush Current Protection Circuit. Since VS5P, VS75P employs Power Thermistor Inrush Current Protection Circuit, Inrush Current becomes large at high temperature or during re-input after the operation. VS1P, VS15P employs Triac as protection circuit. Please be careful when selecting the input switch and the external fuse. will be shut down. After cutting input voltage for a few minutes, please re-input for recovery of the output voltage. OVP setting can not be changed, since it is fixed. 3-5. Over Current Protection ( OCP ) Constant current limiting, automatic recovery. OCP function operates when the output current exceeds 12% of peak output current of specification. The output voltage will be automatically recovered when the overload condition is removed. Do not operate in overload or dead short conditions for more than 3 seconds. It could result in damage or insulation failure. 3-6. Ripple & Noise The maximum ripple value of a specification standard is measured according to measurement circuit specified by JEITA-RC9131. When load lines are longer, ripple becomes larger. In this case, it is better to connect electrolytic capacitor, film capacitor, etc., across the load terminal. The output ripple can not be measured accurately if the probe ground of oscilloscope is too long. 3-4. Over Voltage Protection ( OVP ) The OVP function ( Inverter shut down method, manual reset type ) is provided. OVP function operates within 115-135% of rated output voltage. When OVP operated, the output voltage 4

3-7. Series Operation Following Series operation ( A ) or ( B ) is possible. Method ( A ) Power Supply (B)Using as Back-up Power Supply is possible. 1. Set power supply output voltage higher for the forward voltage drop (VF) of diode. 2. Adjust the output voltage of each power supply to be the same. 3. Use output voltage and average output power within the specifications. Load Load Method ( B ) Power Supply Load Load 3-9. Peak Current current can cope with peak current loads. Specified maximum average output current and peak output current must satisfy formulas below. During peak current operations, maximum allowable average current value must not be exceeded. Allowable peak output operating duration is less than 1sec. 3-8. Parallel Operation (A) Increasing the output current by parallel operation is not possible. Moreover, please use according to following peak output current duty derating. When using pulse load, noise may be heard from power supply unit. Please evaluate and check before using. Load Ip A T Im Iav Im Ip 5

aa A Ip Iav Im Ip : Peak output current ( A ) Ip a a Iav : Average output current ( A ) ( Average output current of Specification ) Im : Average output current ( A ) : Pulse width of peak output current ( sec ) ( Operating time at peak output ) T : Period ( sec ) T Im 3-1. Isolation Test Isolation resistance between output and FG shall be more than 1M at 5VDC. For safety operation, voltage setting of DC isolation tester must be done before the test. Additionally, make sure you discharge sufficiently by resistance etc., after the test. ~ FG 5VDC 1M or more Isolation Tester AC(L) AC(N) FG +V -V Peak Duty Derating VS5P 5 Duty ( % ) Duty( % ) 3 1-1 5 6 Ta ( ) VS75P,VS1P,VS15P 5 3 1-1 5 6 Ta ( ) 3-11. Withstand Voltage This series can withstand 2.kVAC between input and output, 2.kVAC between input and FG, and 5VAC between output and FG, each for 1 minute. When testing withstand voltage, set current limit of withstand voltage test equipment at ma. The test voltage must be gradually increased from zero to testing value. And gradually decrease also for shut down. When timer is used, the power supply may be damaged by high impulse voltage generated during applying or shutting off voltage. Connect input side and output side as follows. When output is left open during tests, output voltage might appear momentarily. 6

Input ~ ( dotted line ) 2kVAC 1min. ( ma ) Input ~ FG( solid line ) 2kVAC 1min. ( ma ) Withstand Voltage Tester AC(L) AC(N) FG +V -V 4. Mounting Directions 4-1. Derating according to the Mounting Directions Recommended standard mounting method is ( A ). Method ( B ), ( C ), (D), and (E) are also possible. Refer to the derating below. Please do not use installation method (F). The following derating values are maximum average output power and current values at rated output voltage as 1%. (A) (B) ~ FG 5VAC 1min. ( 1mA ) STANDARD component HEAT SINK AC(L) AC(N) INPUT +V Withstand Voltage Tester FG -V (C) INPUT (D) INPUT HEAT SINK OUTPUT (E) (F) OUTPUT component INPUT 7

Derating (Convection cooling) VS5P VS1P Average output power & current ( % ) 1 8 6-1 Mounting (A),(B),(C) Mounting (D),(E) 5 6 Ta( ) Average output power & current ( % ) 1 8 6-1 Mounting (A) Mounting (B),(C) Mounting (D),(E) 5 6 Ta ( ) VS5P Derating Average output power & current (%) Mounting A B C D E Ta -1~+ 1 1 1 1 1 +5 1 1 1 7 7 +6 VS75P VS1P Derating Average output power & current (%) Mounting A B C D E Ta -1~+25 1 1 1 1 1 + 1 1 1 78.6 78.6 +5 1 8 8 64.3 64.3 +6 7 6 6 5 5 VS15P 1 1 Average output power & current ( % ) 8 6-1 Mounting (A) Mounting (B),(C),(E) Mounting (D) 3 5 6 Ta ( ) Average output power & current ( % ) 8 6-1 Mounting (A) Mounting (B),(C),(D) Mounting (E) 3 5 6 Ta ( ) VS75P Derating Average output Power & current (%) Mounting A B C D E Ta -1~+3 1 1 1 1 1 +35 1 1 1 93.3 1 +5 1 76 76 73.3 76 +6 7 6 6 6 6 VS15P Derating Average output power& current (%) Mounting A B C D E Ta -1~+3 1 1 1 1 1 + 1 83.4 83.4 83.4 1 +5 1 66.7 66.7 66.7 75 +6 5 5 5 5 5 8

Derating (Forced air cooling) For forced air cooling, airflow of more than.7m/s is needed for component side. As reference, air-cool such that E-cap.(C6) temperature becomes lower than 75. 4-2. Mounting Method Please use the mounting hole as: VS5P~VS15P: 4 holes of φ3.5 Insert the spacer (MAXφ6mm) of height over 6mm to lift the unit. Also use all 4 mounting holes for the unit installation. The vibration specification is the value taken when the unit is raised by 6mm spacers. VS15P HEIGHT MORE THAN 6mm SPACER Average output power & current ( % ) 1 8 6-1 5 6 Ta ( ) Also, allowable area for metal pieces is 8mm from each PCB corners. Refer to figure below. VS15P Derating Average output power & current (%) Mounting A,B,C,D,E Ta -1~+5 1 +55 85 +6 7 When mounting this unit (PCB), please allot space to satisfy isolation and withstand voltage specifications. Furthermore, to convection cooling, component side ventilation is necessary. 9

Please allot more than 2mm space from the surfaces and the sides of PCB. Additionally, 6mm space is necessary from the solder surface. If the space is not enough, the specification of insulation and withstand will not be satisfied. FG should be connected to the earth terminal of the apparatus. If not, the returned noise of input, and output noise will increase. 5. Wiring Method The input and output lines should be separated and twisted to reduce noise sensitivity. The input and output lines should be as thick and short as possible to reduce impedance. Noise can be eliminated by attaching a capacitor to the load terminals. For safety and EMI, FG terminal must be connected to ground terminal of equipment using thick wires. Recommended screw torque is.49n.m (5kg.cm). Select wire materials suitable for connector as follows. INPUT : VS5P~15P---AWG#22~#18 OUTPUT : VS5P~15P---AWG#22~#18 6. External Fuse Rating Please refer to the following fuse rating when selecting the external fuses that is used on input line. Surge current flows when input voltage is applied to line. Therefore, use slowblow fuse or time-lug fuse. Do not use fastblow fuse. Fuse rating is specified by in-rush current value by applying input voltage. Do not select the fuse from input current (rms.) values of the actual load condition. VS5P : 4.A VS75P : 5.A VS1P : 5.A VS15P : 6.3A 1

7. Before concluding that the unit is at fault Before concluding that the unit is at fault, make the following checks. Check if the rated input voltage is connected. Check if the wiring of input and output is correct. Check if the wire material is not too thin. Check if the output voltage trimmer (V.ADJ) is properly adjusted. Check if the output current and output power are not used over specification. Audible noise may be heard during Dynamic- Load operation. Ensure that a large capacitor is not connected on the output side. Please use within maximum capacitance shown below. VS5P : 1,μF VS75P : 3,μF VS1P : 3,μF VS15P : 3,μF 8. Notes 1. Overvoltage CategoryⅡ 2. Radio Interference Suppression Test is not performed. 11