Installing the Focus Motor

Similar documents
Installing the Focus Motor

IRF90 - Rotating Focuser

Pegasus Astro Dual Motor Focus Controller v3.0. Thank you for choosing our Dual Motor Focus Controller v3.0 (DMFCv3)

Pegasus Astro Dual Motor Focus Controller v2.0

Pegasus Astro Stepper Motor Focus Controller v1.x

Artemis Focuser User Guide. S Chambers

Seletek. Tarsier. User's manual

Installation and Setup Instructions. FeatherTouch ASCOM Driver

TCF-Lynx 2-inch Focuser Installation

HitecDC Focus User Manual

Software Setup Instructions for the Foster Control System used in the Explora Dome Observatories

TCF-S Commander Help

Optec Pyxis Help 1 / 56

ASTRO-PHYSICS GTO CONTROL BOX FOR SERVO DRIVE Model GTOCP1

CNC Controller Quick Start Guide

Baader SteelDrive Instruction Manual

TOC F1 Operations Manual

Mount Hub Pro v1.31 User Manual

CCD Astronomy. Imaging the Deep Sky. Ken Westall. Abell 1656 Coma Galaxy Cluster

Super high resolution cooled astronomical camera QHY27/28/29M. User s Manual Rev. 1.0

Z Series and S4M Ribbon Take-Up Spindle Maintenance Kit

WHAT YOU LL NEED TABLE OF CONTENTS. Second Shooter Plus Slider Motor Mount Camera Control Cable (or external intervalometer)

700TSU INSTALLATION MANUAL

EPS 06 in rear housing type A1

For more details on CCD imaging, visit and see the Guide to CCD Imaging.

This page outlines some of the alternate pieces that can be used for building.

PC Focus Control Operator's Guide

Software Manual. Revision 1.3

VEX ARM Cortex -based Microcontroller and VEXnet Joystick User Guide

Quick Start Guide MC-III TM Flow Analyzer

Temperature-Humidity Sensor Configuration Tool Rev. A 1/25/

Digivu Quick Start Guide. Digivu User Instructions

THE CONTROLLER. e) f) g) h) i) j) k) a) Menu Button Navigate backwards to the previous menu with this button.

Options. Parts List. Optional Expansion Hub Optional Ignition Module Optional Memory Card

TOC DX1-K Operations Manual

DESIGNED & MANUFACTURED by FLOATCAM

ZLog Z6R Altitude Data Recording and Monitoring System

SUM-40 OPERATING MANUAL. Ma0 DYNAMIC STRUCTURES AND MATERIALS, LLC REV

Firmware install with Windows XP

Smart Focus. Operator's Guide. Copyright 2013 JMI Telescopes Jim's Mobile, Inc W 14th Ave Lakewood, CO U.S.A.

Upchurch Scientific Nano Flow Sensor User s Guide

VP- X Pro & VP- X Sport

User s Manual Computerized Focus-Smart Controller Pro (Model CFS-Pro, CFS-R)

Table of Contents Introduction... 4

CONTROL4 INTEGRATION WITH THE SHADE STORE MOTORS CONTROL4 INTEGRATION OVERVIEW:

VERSION 1.1 SEPTEMBER 12, 2017 ULTIMATE POWERBOX PRODUCT MANUAL BY PEGASUS ASTRO [COMPANY ADDRESS]

Parts List. The HyperStar Lens Assembly includes three pieces: HyperStar Lens Secondary Mirror Holder Counterweight

Mt. Stony Brook Meade 14-inch Set Up and Operations Manual

E102 - Advanced Strain Gauge Transducer Display Interface. Contents

Please read and understand this instruction manual thoroughly before using this product.

For more details on CCD imaging, visit and see the Guide to CCD Imaging.

AbraScan Test Strip Reader Digital Reading of Test Strips for the Determination of Cyanotoxins in Contaminated Water Samples

1. Learn about LabView software and its different components

MantraJet 1100 CD/DVD autoprinter Operator s manual

For more details on CCD imaging, visit and see the Guide to CCD Imaging.

Dreamer Series User Manual

eturboware 4.x For Windows 2000/XP User s Guide Part No: M , Ver:1.0

Available Map Views & Dash View Screen

CIFER Standards Converter

Graphical User Interface V1.0.3

CncGcoder Models HD & HDx Manual

User Manual. Thermo Scientific Orion

Astrel Instruments. AST-8300-B GETTING STARTED rev A. Getting Started 1/21 rev A

FAC-R Frequency to Analog Converter Installation, Operating & Maintenance Manual

Rotas Noise Analysis System Quick Start and Setup Guide

Computer Interface for Focusmate Driver/Digital Indicator. Operating Guide

Operating Manual. for HXOC Page 1 of 5

Lightning Stitch Assembly

TT230SM THERMAL TRANSFER PRINTER USER S MANUAL

quick start manual PERSONAL NAVIGATOR

Operating Procedure for Horiba Raman Microscope

REMOVE COVERS. 1. Remove three screws from the Side Panel (L). 2. Slide the Side Panel (L) backward, and raise it to remove from the printer.

Please read and understand this instruction manual thoroughly before using this product.

25 Sport Scope Instruction Manual

Catalogue. Assembling... 1 Unpack Charge the Battery Install the Memory Card Product Basics Buttons and Connections...

RC-SV Configuration Guide (Rev 4)

Wireless Network Video Recorder

PD1 & PD1-HT QUICKSTART GUIDE. Remote Air Follow Focus System / High Torque System. What s Included

TSMIU Wireless Bridge Installation and Configuration

ABM International, Inc. Lightning Stitch Checklist 9/13/2013

Table of Contents. Part I USB Communication. Part II User Interface. Part III User Settings (Tab Control) DFS-1000 Dataview. 2 File Menu.

XL-NAS-400SA. User s Guide

TouchKit TouchScreen Controller User Manual for Windows NT4 Version: 3.4.0

contents Page 1 of 6 Field Programming Software User Guide Rev. A 10/16

AG-UX180/UX170 Firmware update procedure

Controller Pro Instruction Manual

CORTEX Microcontroller and Joystick User Guide

Heightronic 235D Assembly & Operation

The SC812/SC812L Chassis Series Installation Guide

TouchKit TouchScreen Controller User Guide for Windows NT4 Version: 3.2.1

Paramount Robotic Telescope Mount Specifications

TEC APO 200 OWNER S MANUAL

Series 2260B DC Power Supply Version 1.82 firmware release notes

USER MANUAL Resolution 0.02mm Speed 300mm/second Software: Wanhao Maker

Instruction Manual. Wi-Fi Full HD 1080p IP Concealed Junction Box Hidden Camera. V 1.3

Edition:2A ODM- 88. DVI Matrix Router USER MANUAL

Written By: Walter Galan

For more details on CCD imaging, visit and see the Guide to CCD Imaging.

AU-EVA1 Firmware update procedure

ERC: Portal Favorites Advanced Options Quick Reference Guide

Transcription:

The MicroTouch Autofocuser is designed to work with Feathertouch Focusers from Starlight Instruments. It allows automatic focusing with CCD and DSLR cameras. Included is FocusMax software to automatically focus the telescope for imaging. Manual focus is also possible using the hand controller. The hand control features an LCD screen for displaying a digital readout of focus position as well as information used for programming the temperature compensation feature. The MicroTouch Autofocuser is compatible with Feathertouch Crayford focusers, Feathertouch SCT MicroFocusers, and Feathertouch MicroFocusers for Takahashi and TeleVue refractors. Optional larger focus motors allow use with the Starlight Instruments 2.5, 3.0 and 3.5 focusers. Motors are also available for non-feathertouch focusers on Sky-Watcher, Stellarvue and Takahashi refractors. Included Parts Hand Control Focus Motor Focuser Gear Motor Connector Cables USB Cable 12-Volt Power Cord (AC or DC, user selected) Hex-Head Wrenches MicroTouch & FocusMax Software Hand control, motor, cables

Installing the Focus Motor The following directions are illustrated using a Feathertouch SCT MicroFocuser, but the instructions are identical for any Feathertouch focuser. 1) Begin by removing both the brass fine focus and black standard focus knobs from the focuser. Use the included medium size hex-head wrench to remove the knobs. 2) Install the small brass gear onto the focus shaft. The gear goes toward the telescope, with the smaller gear hub away from the scope, as shown below. The gear should NOT quite touch the brass bearing hub on the focuser. Insert the gear all the way onto the shaft then back it off slightly. Use the small hex-head wrench to lock the gear in place. Note: The gear has a small insert to allow installation on different size focus shafts. The insert can only be removed from one side. Using one of the hex-head wrenches to push the insert out can be helpful.

3) Slide the focus motor onto the focuser. You may need to rotate the motor slightly to allow the motor gear and focuser gear to mesh. The motor can be rotated to the desired position after the gears have meshed. When installed properly, the motor will completely cover the silver portion of the focuser. Use the large hex-head wrench to lock the motor in place. Connect Hand Control 4) Use the included RJ11 cable to connect the motor to the hand control. Using the MicroTouch Autofocuser Manually You can use the MicroTouch focuser to focus the telescope visually by using the IN and OUT buttons. This is also how you will approximately focus the telescope when using a camera, before using the autofocus routine.

MicroTouch Hand Control Menus The LCD screen light turns on when the hand control is powered up. If desired, press the LIGHT button to turn the light off. Pressing MODE once displays the current ambient temperature. The default display is F. To change to C, press the SET button while the temperature is displayed. The following menus are accessed sequentially by pressing the MODE button: Temp Comp, Learning, Wireless, Motor Rev, and Reset Position. Each is described in detail below. Temp Comp This activates the Temperature Compensation feature of the MicroTouch Autofocuser. Press SET to turn this feature on. In order for the Temperature Compensation feature to work, it must learn how to compensate for changes based on the optical system being used. This is done using the Learning menu (below). Learning The Temperature Compensation feature works by learning how much focus change is necessary to compensate for a given temperature change. For example, on a certain system, a temperature drop of 1 F might require a focus position shift of 25 counts. Therefore, if the temperature drops by 2 degrees, the focuser would move 50 counts to keep the telescope in focus. The focuser must learn the exact focus shift required for a given telescope and configuration (so adding a focal reducer, for example, would require the focuser to be recalibrated). To activate the Learning mode, press and hold the SET button for a few seconds until the display shows Mode: Learning. The word Learning will blink while the focuser is being calibrated. The current position of the focuser is displayed. Press MODE once to view the current temperature. Wait until the temperature has changed. A temperature change of 5 F is recommended for the most accurate calibration. Once the temperature has changed, refocus the telescope (either manually or using the autofocus routine described in the next section). Return to the Learning menu and hold SET again until the display shows Mode: Idle. The temperature compensation is now set. Go to the Temp Comp menu and press SET to turn the temperature compensation on. More advanced temperature compensation control is available through the MicroTouch software.

Wireless This turns the wireless communications on or off. The default for the MicroTouch Autofocuser is OFF. If the autofocuser is upgraded to the wireless version, the mode must be changed to ON. Motor Rev This reverses the direction of the motor. Reset Position The default position of the digital readout is 30000. The range of focus is 0-60000. If the focuser is moved to either end of this range, press MODE until Reset Position? appears. Press and hold the SET button until the display blinks and resets. The position has now been reset to 30000. If a different default position is desired, it is possible to program this using the MicroTouch software (described below).

Installing the MicroTouch and FocusMax Software Load the included CD. Alternatively, you can download the latest installer from the MicroTouch product page on Starizona.com. There are several files that must be installed. If you do not already have the ASCOM Platform installed on your computer, begin by running the ASCOMPlatformXX.exe file. This will take a couple minutes to install. Next, install FocusMax by running the FocusMax(3.8.0.20)setup.exe file. Now we need to install the hardware drivers for the MicroTouch unit. Go into the MicroTouch USB Driver folder. There are two driver installers, depending on whether you have a 64-bit or 32-bit operating system. Most computers with Windows 7 or newer will be 64-bit. Run the StarizonaUSBDriverInstaller_x64.exe (or x32.exe if you have a 32-bit OS). Go back out of the Starizona USB Drivers folder to the main directory. Run the MicroTouchControllerSetup_X_X.exe installer. This will install the MicroTouch Controller application. Finally, run the MicroTouchDriverSetup_X_X.exe file that will install the ASCOM drivers for the MicroTouch.

MicroTouch Software The standalone MicroTouch Controller software lets you manually operate the MicroTouch autofocuser, configure settings, train the temperature compensation, and update the firmware. Launch the MicroTouch Controller application. If you are only using one MicroTouch unit, you should be able to simply press Connect. If you are using multiple units, see the instructions below. Movement Tab When you first connect, you should be on the Movement tab and will see the current position of the MicroTouch displayed in red numbers. You can move the focuser motor in or out by pressing the up and down arrow buttons. To move to a specific position, enter the desired value in the Target Position box and press Goto. To stop the focuser during a goto movement, press the Stop button at any time.

You can reset the current position to any value between 0 and 60000 by entering that value in the Target Position box and pressing Reset to Target Position. Common positions that you use can be stored in the Favorite Locations boxes. For example, if you know your telescope focuses at about 12000 steps with an eyepiece and about 41000 counts with a camera, you can quickly go between those positions. Temperature Tab The Temperature tab is where you can view the current temperature reading from the temperature sensor on the MicroTouch unit, and where you can train and enable temperature compensation. To train temperature compensation, first focus the telescope, then check the box next to Learn. This will snapshot the current position and temperature. You should then wait some time while the temperature drops by several degrees. During this period you can otherwise use the MicroTouch as normal. Once the temperature has dropped by a few degrees, refocus the telescope and uncheck Learn. This will take a second snapshot of the current position and temperature and determine a Coefficient in counts per degree.

(It is also possible to manually enter a coefficient in the bottom box and press New Coefficient to apply it, but this normally isn't necessary.) Once trained, you can click the Snapshot button to get the current info from the MicroTouch unit. You can then click Comp Immediate to update the position based on the current temperature. To run the temperature compensation continuously, check the box next to Enabled. This will continuously read the temperature and update the position as needed until you uncheck Enabled. Diagnostics Tab In the Diagnostics tab you can get info on the hand controller unit and (if you have the wireless MicroTouch) the motor controller unit. The info on the hand controller will show the firmware version number. If you do not have a wireless version, the Number of Corrupted Packets and Number of Comm Timeouts will always read zero. If connected to a wireless unit, you will also see the

firmware version of the motor controller and may have values for corrupted packets and timeouts. Setup Tab The Setup tab lets you adjust the parameters of the MicroTouch unit. Normally the Min and Max Values are set to 0 and 60000, respectively. This is the full range of the MicroTouch digital steps (but not necessarily the physical range, depending on the focuser). If your focuser has less physical range, you can limit the Min and Max Values to keep the focuser from traveling too far. The default value of Steps per Tick is 1. This means each position step corresponds to one step of the stepper motor. This gives the best resolution. Changing this value to 2, for example, moves the motor 2 steps per position number, making the movement faster but less precise.

The Motor Speed option has possible values of Fast and Normal. Fast turns the motor at a higher speed, but provides less torque. If you have a heavy payload on your focuser, you want to use the Normal setting to provide more lifting power. Speed Delay has a default of 0.3 seconds. When you press the In or Out buttons either in the MicroTouch Controller application or on the hand controller unit, this is the delay before the motor ramps up too full speed. This allows you to easily make smaller steps by giving the button short pushes, without the motor wanting to immediately go running off at full speed. Temp Offset allows you to calibrate the temperature sensor. If the sensor reads, for example, 78ºF, but you know the actual temperature is 72ºF, you can enter the actual temperature and press the Set button to calibrate the temperature offset (in this case -6ºF). Motor Reverse allows you to reverse the direction the motor runs so that In and Out actually correspond with the focuser movement, depending on which focuser you use. Updating Firmware Note: The MicroTouch Shuttle uses different firmware than the standard MicroTouch unit. Be careful to upload the right file! The latest version of the MicroTouch firmware is available in the download from the MicroTouch product page on Starizona.com. There are two firmware files, one for the hand controller unit and one for the motor controller unit. The motor controller firmware is only used with the wireless version of the MicroTouch. To update the firmware, make sure the MicroTouch is connected in the MicroTouch Controller application. Then go to the Tools menu at the top and select Upload Firmware. In the Update MicroTouch Firmware window, click on Select File and navigate to the firmware file you downloaded from the Starizona website. The hand controller firmware will be MicroTouch_X_X.bin, where the X's represent the latest version number. The

motor controller firmware will be MicroTouch_Motor_X_X.bin. Firmware for the MicroTouch Shuttle will be MicroTouch_Shuttle_X_X.bin. Be sure to check whether you are programming the Hand Unit or Motor Unit at the lower left of the window. To upload the new firmware, you must press and hold the In and Out rectangular red buttons on the hand controller unit, then press the Program button in the Update MicroTouch Firmware window, then you can release the red buttons. You should see the programming happening. After a few seconds, the program will complete. If you close the Update MicroTouch Firmware window and select the Diagnostics tab, you should see the newest firmware version number displayed. Using Multiple MicroTouch Units Each MicroTouch hand controller unit has a unique 4-digit identifier. This means you can control multiple units on the same computer. To connect multiple units, go to the Focusers menu at the top and select ASCOM Setup. Any currently connected focusers will be disconnected and the MicroTouch Focuser Setup window will appear. In the pulldown menu next to each focuser, you will see the numbers listed of each MicroTouch unit that is currently plugged into the computer. To sort out which number corresponds to which hand controller unit, we recommend plugging them in one at a time to begin with. You can select the number for the unit you want to be Focuser 1 and Focuser 2, etc. Then click OK. You can then select which unit you are controlling using the buttons in the column on the left side of the main window, Main Focuser, etc. Only two buttons show by default. You can show more or less buttons by clicking on the >> icon at the lower right of the column.