Instruction Manual Basic Rack PDU VP7541 and VP9571A

Similar documents
Instruction Manual. Rack PDU XP Series. geistglobal.com

Auto-Transfer Rack Power Distribution Unit

Instruction Manual Rack Power Distribution Unit. J, VHV Series

Instruction Manual Rack In-Line Power Measurement Unit. L Series

Instruction Manual. Rack PDU BRE and VRTE Series. geistglobal.com

Instruction Manual. Rack PDU BR, SP, SVR, VRT, NSV, and VSS Series. geistglobal.com

LVN5200A-R2, rev. 1, Hardware Installation Guide

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

SAFETY WARNINGS AND GUIDELINES

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

Instruction Manual. Rack PDU J, VHV, and MJ Series. geistglobal.com

G5 PDU Installation Guide

3M RFID Tracking Pad Model 770

Zebra RW 420 Mobile Battery Eliminator Kits

Unity 100-watt Bridgeable Power Amp

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

Switched Rack Power Distribution Unit

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

MONOPRICE. ShowPony 12-Watt LED Derby FX Light (RGBW) User's Manual P/N

Handset Charging Rack OpenStage WL 3 / OpenStage WL3 Plus. Installation Guide A31003-M2000-J

elise 3 embedded linux server including safety instructions

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

TWISTED PAIR DISTRIBUTOR KE 0108CH-DW. Instruction Manual. Thank you for your purchase of this product

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

WIRELESS BLUETOOTH BOOMBOX

iconverter 2-Module Power Chassis

2 Mesa Ethernet Dock User s Manual

Installation Guide DRAFTMF4100

HDMI and USB KVM Extender

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

BCM2 Series Branch Circuit Monitors Quick Setup Guide

MONOPRICE. Blackbird 4K Pro 1x2 Ultra Slim HDMI Splitter. User's Manual P/N 21612

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

SB Channel Soundbar with Built-in Subwoofer

Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide

Safety and Radio-Frequency Interference

USER GUIDE. Laptop Charger NS-PWLC591/NS-PWLC591-C. Before using your new product, please read these instructions to prevent any damage.

MONOPRICE. Blackbird 4x4 HDMI Matrix/Extender with 4 Receivers. User's Manual P/N 21905

Liebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL 1.1 SUMMARY

MONOPRICE. Blackbird HDMI Bi-Directional Switch. User's Manual P/N 24280

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

CONVERTEON Family. One-Slot Chassis AT-CV1000. Installation Guide Rev. A

PM Series Power Meter

Instruction Manual Environmental Monitoring Unit with Optional POE. Watchdog 15 Series Firmware Version 1

25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Controller Specifications

Plug-in wireless speaker

USB Raven Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide

CSM200 Expansion Tray

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

Media Conversion Rack-Mount Chassis AT-MCR12. Installation Guide Rev. A

USB 2.0 RG2324/ Port USB 2.0 Fiber Optic Extender System. User Guide

Stage Rack Installation Guide

HD40H(X) Performance Series Camera. User Guide

ShoreTel IP Phone 655. Quick Install Guide & Warranty

KP7 Keypad Quick Install Guide

HomePro ZRF113. Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2

SySTIUM TM TECHNOLOGIES Model 215

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA

Fast Ethernet Switch AT-FS705L. Installation Guide Rev. A

SANnet II Family Safety, Regulatory, and Compliance Manual

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4

USB Raven Port USB 3.1, 100m CAT 6a/7 Point-to-Point Extender System User Guide

User Manual. Per Port Monitoring Models

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

WCC100 IN-VEHICLE CHARGING CRADLE OWNER S MANUAL

IPS-800/1600-D20 Series

Infosystem Remote Touchscreen Installation Instructions

OVERVIEW. *Press and release. *Hold for 5 seconds. *Charging port

This document will show you how to set up the Hotwire 6205 ADSL Modem, and how to customize its configuration to get the most out of this product.

100 - SERIES NETWORK SWITCHES QUICK START GUIDE

MONOPRICE. Blackbird 4K HDMI 1x8 Splitter/Extender. User's Manual P/N 18787

3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE

SAFETY WARNINGS AND GUIDELINES

PD-6506, PD & PD-6524

NCH-1000 (Multiple Breaker Types) Installation Instructions

* * Agilent Power Distribution Unit (PDU) Installation Guide

Emotiv Insight User Manual. Revision 1.0 June 2015 Emotiv Inc, 2015

Solarflare X2522 network adapter Quick Start Guide

Power Distribution. For technical support call Online catalog available at leviton.com 461

MAJOR VA Power Inverter

ANI SWH. PDU: Per Outlet Control and Total Current Monitoring INSTRUCTION MANUAL

PV Rapid Shutdown device

WTI Part No Rev. H. VMR Series. Managed Power Controllers. NPS Series. Network Power Switches. User's Guide

Ultra Slim Multimedia Keyboard (KB3100MF)

Changes or modifications not expressly approved by InFocus Corporation may void authority to operate the equipment.

Broadband Automatic Disconnect Switch. User Manual

Universal Charge & Sync Cabinet for Tablets/iPads - 10 Slot Charging Station with Lock and Fan

Wireless Smart Water Leak/Flood Sensor

Theatrixx Technologies USER MANUAL. XVISION CONVERTER HDBT TO HDMI (RECEIVER) PowerCON in/edison out TXVV-HDBT2HDMI

Quick Start Guide. C-100 Series Switches

Transcription:

Instruction Manual Basic Rack PDU VP7541 and VP9571A VertivCo.com/geist

Table of Contents Specifications... 3 Overview... 3 Environmental... 3 Temperature... 3 Humidity... 3 Elevation... 3 Electrical... 3 Receptacle Ratings... 3 EMC Verification... 3 Installation... 4 Instructions... 4 Guidelines... 4 Mounting... 5 Optional Local Monitoring... 12 Power Meter... 12 Current Meter... 12 Service/Tech Support... 13 Service and Maintenance... 13 More Technical Support... 13

BASIC RACK PDU 3 Specifications Overview The Vertiv Basic Rack PDU products are Power Distribution units (PDU) intended for connection to a 30 Amp AC Mains circuit. The PDUs are designed to be powered by a single phase AC input circuit. The Vertiv Basic Rack PDUs covered by this manual are available in vertical or horizontal configurations rated 208-240V and can be optionally configured with a Vertiv Power Meter that provides local monitoring and display of Current, Voltage, Wattage, and Power Factor. Environmental Temperature Operating: 10 C (50 F) min 45 C (113 F) max Storage: -25 C (-13 F) min 65 C (149 F) max Humidity Operating: 5% min 95% max (non-condensing) Storage: 5% min 95% max (non-condensing) Elevation Operating: 0 m (0 ft) min 2000 m (6561 ft) max Storage: 0 m (0 ft) min 15240 m (50000 ft) max Electrical See nameplate for unit ratings. Receptacle Ratings NEMA 5-15R or L5-15R NEMA 5-20R or L5-20R NEMA 6-20R or L6-20R IEC-320 C13 IEC-320 C19 125 Volts, 15 Amp 125 Volts, 20 Amp 250 Volts, 20 Amp 125/250 Volt, 15 Amp (per Receptacle Bank) 125/250 Volt, 20 Amp EMC Verification This Class A device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment.

BASIC RACK PDU 4 Installation Instructions 1. Using appropriate hardware, mount PDU to rack (see Mounting section for additional instructions. 2. Plug PDU into de-energized 30 Amp branch circuit receptacle.** 3. Connect devices into PDU s output receptacles. It is recommended that the devices are turned off until all devices are connected to PDU 4. Turn on branch circuit to energize PDU. 5. Power on devices. Sequential power up is recommended to avoid high inrush current. **Branch Circuit should be sized based on the PDU s nameplate electrical rating. A 24 Amp rated PDU is intended for use on a 30 Amp Branch Circuit. For Global Units a 32 Amp rated PDU is intended for use on a 32 Amp Branch Circuit. Guidelines If the PDU is installed in a cabinet the ambient temperature of the rack should be no greater than 45C. Install the PDU such that the amount of airflow required for safe operation of equipment is not compromised. Mount the PDU so that a hazardous condition is not achieved due to uneven mechanical loading. Follow nameplate ratings when connecting equipment to the branch circuit. Take into consideration the effect that overloading of the circuits might have on over-current protection and supply wiring. The PDU relies on the building installation for protection from over-current conditions. A certified overcurrent protection device is required in the building installation. The overcurrent protection device should be sized according to the PDU s nameplate ratings and local/national electrical codes. Reliable earthing of rack-mount equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit. The PDU must be connected to an earthed socket-outlet.*** The PDU is intended for Restricted Access Locations only and only qualified service personnel should install and access the PDU. For pluggable equipment, install the PDU so that the input plug or appliance coupler may be disconnected for service. Sequential power-up of devices powered by the PDU is recommended to avoid high inrush current. Caution: Disconnect all power cords before servicing. The PDU is intended for use with TN, TT, or IT power supply systems ***XP Series PDUs may optionally be configured as Isolated Ground units. All Isolated Ground units will be shipped with an enclosure grounding cable. This cable must be connected between the enclosure and a reliable safety ground.

BASIC RACK PDU 5 Mounting Full Length Bracket Using the full length bracket, mount PDU to rack as shown Mini "L" Brackets (SLB-4)

BASIC RACK PDU 6 Using the mini L brackets, attach PDU to rack as shown Vertical Extension Brackets (VCB-1) Using the vertical extension brackets, attach PDU to rack as shown Toolless Mounting Hardware (11621) Secure toolless mounting buttons to PDU as shown. Use toolless buttons with key-holed slots built into cabinet or with optional Vertiv key-holed brackets.

BASIC RACK PDU 7 Toolless Full Length Bracket (TLFL) Using full length toolless bracket and toolless mounting buttons, attach PDU to rack as shown Single Side Mount 2 Unit Brackets (TSMX2) Using single side mount 2 unit brackets and toolless mounting buttons, attach PDU to rack as shown

BASIC RACK PDU 8 Offset/Side Mount Brackets (EZB-1) Using the offset/side mount brackets, attach PDU to rack as shown. 7" Extension Brackets (XB-7) Using the 7 extension brackets, attach PDU to rack as shown

BASIC RACK PDU 9 Flush Mount Brackets (FM) Using flush mount brackets, attach PDU to rack as shown Adjustable Mount Brackets (AM) Using adjustable mount brackets, attach PDU to rack as shown

BASIC RACK PDU 10 Panel Mount Brackets (PM) Using panel mount brackets, attach PDU to rack as shown 23" Conversion Mounting Brackets (23-RM) Using conversion mounting brackets, attach 19 PDU to 23 rack as shown

BASIC RACK PDU 11 Cable Mount Bracket (CMB-1) Attach cable mount bracket to PDU as shown; use tie-wraps to secure cords to bracket 19" Horizontal/Panel Mount Brackets (7938) Using the 19 horizontal/panel mount brackets, attach PDU to rack as shown

BASIC RACK PDU 12 Optional Local Monitoring Power Meter The Vertiv PM-1 power meter is a low-power, high accuracy meter capable of measuring true RMS Current, Voltage, Power, and Power Factor. These values are individually shown on an easy to read, 4-digit LED Display, which continuously scrolls through the four different measured values. Each one of these displayed parameters is defined below. The Power Meter will automatically begin cycling through the displayed values when the PDU is connected to AC Mains power. Current: PDU output current draw measured in true RMS Amps Voltage: PDU output voltage measured in true RMS Voltage Power: PDU output power measured in Watts referred to as real or active power Power Factor: Ration of real PDU output power to apparent PDU output power**** Power Meter Display ****Real power is the power in a circuit that is transformed from electric to non-electric energy, while apparent power is the total power supplied to the circuit. Current Meter The Vertiv CM-1 current meter is a low-power, high accuracy meter capable of measuring true RMS Current. The value of current is continuously shown on an easy to read, 4-digit LED Display. The Current Meter will automatically begin to display value of output current when the PDU is connected to AC Mains power. Current Meter Display

BASIC RACK PDU 13 Service/Tech Support Service and Maintenance No service or maintenance is required. Do not attempt to open the PDU or you may void the warranty. No serviceable parts inside. It is recommended that power be removed from the unit before installing or removing any equipment. More Technical Support VertivCo.com/geist Phone Support 1 800 432 3219 Email: support@vertivco.com or contact your distributor Technical Support Form: vertivco.com/tech-support

BASIC RACK PDU 14 Thank You For Purchasing Your Vertiv Product VertivCo.com/geist