Installation Instructions of TitrIC 1

Similar documents
Installation Instructions of TitrIC 3

Application Bulletin 318 e. Installation Instructions of TitrIC 4

Application Bulletin 321 e. Installation Instructions of TitrIC 7

Accessories for

870 KF Titrino plus. Installation and tutorial EN

Accessories for

Tutorial EN

TitrIC Vario pro. Multi parameter analysis by titration and ion chromatography combined

915 KF Ti-Touch. Tutorial EN

Accessories for

Accessories for

Accessories for MVA 13

848/877 Titrino plus. Tutorial EN

Accessories for

856 Conductivity Module 867 ph Module

815 Robotic Soliprep for LC

Installation instruction for MVA-20: 894 Professional CVS fully automated for CVS determinations. Content

Accessories for

Accessories for

Accessories for

Accessories for

916 Ti-Touch. Tutorial EN

815 Robotic USB Sample Processor XL

Accessories for

815 Robotic USB Sample Processor XL

831 KF Coulometer. Never before has coulometric Karl Fischer water determination been so economical!

862 Compact Titrosampler

824 Easy Sample Changer

917 Coulometer. Tutorial EN

814 USB Sample Processor

852 Titrando. Manual EN /

730 Sample Changer. and 759 Swing Head. A Short Introduction and Tutorial

Application Bulletin 418/1 e

907 Titrando. Manual EN

1 Purpose. 2 New features. MagIC Net 3.0 Release Notes

915 KF Ti-Touch / 916 Ti-Touch. Compact titrator for routine analysis

1 Purpose. 2 New features. Release Notes tiamo 2.4

Appendix 1: DataStudio with ScienceWorkshop Sensors Tech Tips

Operating Instructions. Titrator DL15

916 Ti-Touch. Manual EN

902 Titrando. Manual EN

General Catalog Herisau CH-9101 G, A ohm Metr by atalog 2014 witzerland S al C in Subject to modifications Printed

Introduction: Features:

917 Coulometer. Manual Short Instructions EN /

898 XYZ Sample Changer

885 Compact Oven SC. Manual EN

874 Oven Sample Processor

870 KF Titrino plus. Manual EN /

885 Compact Oven SC. Manual EN /

902 Titrando. Intelligent potentiometric titrator STAT titrator and synthesis controller

902 Titrando. Intelligent potentiometric titrator STAT titrator and synthesis controller

774 Oven Sample Processor

905 Titrando. Manual EN

875 ProcessLab. At-line Analyzer for Process Analysis

801 Stirrer. Manual EN

905 Titrando. Manual EN /

Automation in titration. Automation in titration

Dionex AS-AP Sample Conductivity and ph Accessory Setup and Operation Guide

CH-9101 Herisau/Switzerland Internet Titrando. Installation Instructions

The Olis Titrator Series

904 Titrando. Manual EN

916 Ti-Touch. Manual Short Instructions EN

Titration Automation. Fully Automate your Titration Processes for Maximum Efficiency and Security. Titration Automation

Determination of suppressor with CVS using the calibration technique smartdt with dynamic addition volumes

HI FORMOL NUMBER MINITITRATOR for Fruit Juices and Wines analysis

856 Conductivity Module

Operating Instructions. METTLER TOLEDO DL77 / DL70ES / DL67 Titrators RESET EXIT RUN

User Manual. Coulometric KF Titrator C10S/C20S/C30S

Catalog.

899 Coulometer. Manual EN /

888 Titrando. Manual EN /

Determination of suppressor with CVS using the calibration technique «smartdt» with dynamic addition volumes

ph 8+ DHS ph- mv - Temperature GLP - USB Data Logger - RS232 printer

ProLab 1. ProLab 1000: ph for the professional. ph Meter ProLab 1000: Superior technique in a classy metal body. Precise measurements

Professional Waterproof Meters

703 Laboratory Conductivity Meter

728 Magnetic Stirrer

Using I9131 Sodium Combination ISE on 3200I/M

CH142: Instructions for the Vernier LabPro

4 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (max.) Up to 7 plates / run Reaction / reading system

912 Conductometer 913 ph Meter 914 ph/conductometer. The new generation of Metrohm meters for ph and conductivity measurement

Electrodes, Cells, Sensors & Accessories Superior sensors. Precise results.

PC/LIMS Report Guide. Metrohm AG CH-9100 Herisau Switzerland Phone Fax

HI FREE & TOTAL SULFUR DIOXIDE MINITITRATOR for wine analysis

Checklist for the SMPS & CPC (5.400 & 5.500) PART 1 Setup of the external Plumbing (for the DMA and the CPC):

774 Oven Sample Processor

tiamo TM Titration and more Networked Titration Data System

Mitos P-Pump. product datasheet

for measuring ph values and redox potential, conductivity and dissolved oxygen Content

DDS-12DW Benchtop Conductivity Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Signet Conductivity Electrodes

Electrodes, Cells, Sensors & Accessories Superior sensors. Precise results.

The Model 703 offers a wide range of practical features to meet the numerous requirements of everyday measuring tasks.

Sepacore X10 / X50 system Technical data sheet

ProfiLine Handhelds. For ph, ISE, Dissolved Oxygen and Conductivity

Agilent ICP-OES SVS 2 Productivity Package Installation and Upgrade Instructions

FROG-4000TM Quick Start Guide

Instruction Manual HI Titratable Acidity Mini Titrator & ph Meter for Dairy Products

CONTROLLERS. Chemical Injection skids. Water Quality Monitoring Systems cum dosing (WQMSD) Mobile Disinfection/Dosing systems

890 Titrando. Manual EN /

Transcription:

861 Single Channel Advanced Compact IC with 815 Robotic Sample Processor Metrohm Metrohm 800 Dosino 800 Dosino 20 ml VENT 10 ml VENT Metrohm Metrohm 800 Dosino 800 Dosino 50 ml VENT 20 ml VENT 809 Titrando 815 712 6.2055.100 The TitrIC 1 System with one 861 Compact IC, an 815 Robotic Sample Processor and 809 Titrando The TitrIC 1 System is used for the fully automatic analysis of water samples using direct measurement, titration and ion chromatography. The following measured values are determined in a very short time: temperature, conductivity, ph, acid capacity, calcium, magnesium, total hardness and, in parallel, the concentrations of the individual anions. Further Metrohm instruments can be incorporated in the existing system at any time and used to measure additional parameters. Analytical sequence 1. Conductivity is measured in the sample vessel on the sample changer. 2. First sample transfer to the 861 Advanced Compact IC. 3. The IC measurement is started automatically. 4. Second sample transfer to the external cell of the 815 Robotic Sample Processor. 5. Temperature, ph and acid capacity (p and m values) calcium, magnesium and total hardness are determined. The whole procedure is controlled by the TitrIC software: The user enters the sample position and sample identification, IC system and tiamo method, after which TitrIC transfers all the relevant information to tiamo and IC Net. When the measurement has been concluded, TitrIC automatically generates a joint report containing all results. This report can be printed out or produced as an Excel table.

Page 2/16 Table of contents 1 Delivery package... 3 2 Installation... 4 2.1 815 Robotic Sample Processor... 4 2.2 712 Conductometer (2.712.0010)... 4 2.3 Titrando (2.809.0020)... 4 2.4 Dosino holder (6.2055.100)... 4 2.5 861 Advanced Compact IC (2.861.0020)... 4 3 Cable connections... 5 4 Tubing connections... 7 4.1 External cell... 7 4.2 Installation of the 50 ml Dosing Unit... 8 4.3 Overview of all the tubing connections... 9 5 Miscellaneous... 11 5.1 Stirrer... 11 5.2 Length of the aspiration tips in the external cell... 11 5.3 Electrodes... 11 6 Software... 12 6.1 Installation of the software... 12 6.2 Configuration of tiamo... 12 6.2.1 Devices... 12 6.2.2 Swing Head configuration... 12 6.2.3 Special beaker definition... 13 6.2.4 Lift positions... 13 6.2.5 Solutions... 13 6.2.6 Electrodes... 14 6.2.7 Methods... 14 6.2.8 Configuration of the export template... 15 6.3 Configuration of IC Net... 16 6.4 Configuration of TitrIC... 16

Page 3/16 1 Delivery package - delivered with TitrIC 1 package: Number Article no. Article designation IC 1 2.861.0020 861 Advanced Compact IC «MSM II» (anions) 1 2.145.0320 Edgeport/4 USB Converter Sample processor 1 2.815.0020 815 Robotic USB Sample Processor XL with 2 pumps 1 2.786.0040 Swing Head 1 6.1462.050 Titration head Conductometry 1 2.712.0010 712 Conductometer 1 6.0912.110 Conductivity measuring cell made of PP, with Pt 1000 1 6.2125.110 Cable to Edgeport USB Converter Titrations / ph measurement 1 2.809.0020 Titrando (with 2 measuring inputs) 1 6.0257.000 Aquatrode; combined ph glass electrode (with temperature measurement) 1 6.0508.110 Polymer membrane electrode Ca 1 6.2151.000 Cable USB A - mini-din 8P 1 6.2106.020 Electrode cable with 2 x plug B (4 mm, 1m) 1 6.2104.020 Electrode cable 1 m, F Liquid Handling 4 2.800.0010 800 Dosino 1 6.3032.250 807 Dosing Unit, glass, 50 ml 2 6.3032.220 807 Dosing Unit, glass, 20 ml 1 6.3032.210 807 Dosing Unit, glass, 10 ml 1 6.2055.100 Dosino holder 3 6.1608.030 Glass bottle GL45 1L (round) 1 6.5620.000 Connecting set for Dosing Unit: Dosino port 4 1 6.2744.080 Coupling M6-UNF 10/32 (Dosing Unit IC screw) 1 6.2744.070 Pressure screw made of PEEK, short 1 6.1543.080 Aspiration tip 1.5 / 240 mm External cell 1 2.802.0020 802 Rod Stirrer 1 6.2001.070 Stand support for 804 1 6.1414.060 Titration vessel lid micro 1 6.1415.220 Titration vessel 6 6.2730.030 Stopper with nipple and O-ring 1 6.1543.210 3-way stopper with antidiffusion valve 1 6.2730.080 Screw nipple 1 6.2730.020 Septum stopper 3 6.2730.060 Screw nipple for electrodes Connection tubings 1 6.1805.060 Connection tubing FEP, L = 60 cm, 2 x M6 thread, i.d. = 2 mm 4 6.1805.030 Connection tubing FEP, L = 150 cm, 2 x M6 thread, i.d.= 2 mm 1 6.1803.020 PTFE capillary, L = 5 m, i.d.= 0.97 mm Software 1 6.6056.112 tiamo 1.1 full - optional accessories: 1 6.2041.xxx Sample rack made of PVC 1 6.1432.xxx Sample beaker 1 6.1006.xxx Anion column Metrosep A Supp x 1 6.1006.xxx Guard column Metrosep A Supp x 1 6.1010.xxx Cation column Metrosep C x 1 6.1010.xxx Guard column Metrosep C x 1 2.853.0010 853 MCS CO 2 Suppressor 1 2.861.0500 Column Oven for 861 1 6.2323.000 Storage solution 1 6.2308.020 Electrolyte solution (3 mol/l KCl) 1 6.2301.060 Conductivity standard 1 6.2307.100/110/120 Buffer solutions 500 ml, ph 4 / 7 / 9

Page 4/16 2 Installation The following is a detailed description of the TitrIC 1 System's installation. We strongly recommend that the individual steps are carried out in the order given below! 2.1 815 Robotic Sample Processor The sample processor is placed at the side at which it is most easily accessible. Please note that the following procedure refers exclusively to the version in which the 815 Robotic Sample Processor is located at the left-hand side of the system. On the right-hand side of the 815 Robotic Sample Processor, attach the stand support (6.2001.070) without the horizontal brace to the tower of the 815 (hexagon screw beneath membrane pump 1). The brace will be installed later. Do not screw the titration head (6.1462.070) onto the Swing Head! The Sample Rack supplied is screwed onto the 815. In the vicinity of the 815 the two canisters (standard equipment of 815) are placed on the floor: One 10 L canister is used as a waste container, the second as a reservoir for deionized (DI) water used for rinsing the external cell. From the smaller opening of the canisters containing DI water, an M8 PTFE tubing connection of suitable length is led to the connection box made of white plastic of membrane pump 1 and connected. From the front opening of the waste canister an M8 PTFE tubing connection of suitable length is led directly to membrane pump 2 (black plastic) and connected. A more detailed description is given in the Instructions for Use of the 815 Robotic Sample Processor. 2.2 712 Conductometer (2.712.0010) The 712 Conductometer is placed directly to the right of the 815 Robotic Sample Processor. For detailed information about the usage check the Instructions of Use of the 712. It is recommended to carry out the calibration of the cell constant manually and before tiamo is started up. Consult thereto the Installation Instructions of the 712 Conductometer, chapter 4.4.3. But firstly the 712 has to be registered in the configuration of tiamo so that the calibration can be stored. Thereto the calibration should be made later when the 712 is registered and tiamo shut down. 2.3 Titrando (2.809.0020) Directly to the right of the 712 Conductometer, place the Titrando with the titration solution (0.05 M EDTA, at the front, with 10 ml Dosing Unit and 800 Dosino) and the auxiliary complexing solution (0.2 M TRIS / 0.1 M Acetylacetone, at the rear, with 20 ml Dosing Unit and 800 Dosino). 2.4 Dosino holder (6.2055.100) The Dosino holder (6.2055.100) is placed at the back of the Titrando and the 712 Conductometer; the 50 ml (6.3032.250) Dosing Unit is screwed and the 20 ml (6.3032.220) Dosing Unit is placed with its 0.1 M HCl titration solution onto this holder at a later stage. 2.5 861 Advanced Compact IC (2.861.0020) Place the 861 Advanced Compact IC for anions (2.861.0020) to the right of the bottle holder. The instrument can already be installed. Please consult the Instructions for Use for the Advanced Compact IC instrument.

Page 5/16 3 Cable connections The numbers given here (, ) refer to the drawing on the next page. First all the power cables are connected to the instruments. Both the instruments and the PC remain switched off. USB cable from Edgeport to PC supplied with USB Converter Edgeport/4 (2.145.0320) RS cable (6.2125.110) from 712 Conductometer to Edgeport port 1 RS cable (6.2134.100) from 2.861.0020 IC to Edgeport port 2 supplied with 861 USB cable (6.2151.000) from PC to 809 Controller, do not connect! MSB cable from Dosino 800, 50 ml (Liquid Handling) to 809 MSB 1, do not connect! MSB cable from Dosino 800, 20 ml (0.1M HCl) to 809 MSB 2, do not connect! MSB cable from Dosino 800, 10 ml (EDTA solution) to 809 MSB 3, do not connect! MSB cable from Dosino 800, 20 ml (Auxiliary complexing solution) to 809 MSB 4, do not connect! USB cable (6.2151.000) from USB 1 of 809 to controller of 815 supplied with 815, do not connect!

Page 6/16 Waste B Waste A Stirrer USB PC 6.2134.100 Analog Output Remote Detector Block RS 232 861 Fuse 100-120V: 1,0A(T) 220-240V: 0,5A(T) Made by Metrohm Herisau Switzerland 1 Controller Ref. Ind. MSB Temp. Pol. 1 MSB RS 232 C USB Contr. 2 3 809 712 815 Remote 6.2151.000 6.2125.110 6.2151.000 Cable connections of the TitrIC 1 System

Page 7/16 4 Tubing connections 4.1 External cell The numbers given here (, ) and «opening 1,...» refer to the drawing below. In the next step the external cell is prepared. The following components are inserted in the titration vessel lid (6.1414.060): The small 6.2730.030 stoppers (with the black rubber ring) are screwed loosely into openings 1, 2, 3, 5 and 7 and fixed in position when the buret tips, etc. are inserted. The large 6.2730.080 stopper will be screwed into opening 9, the septum stopper (6.2730.020) without the upper part into opening 6 and the screw nipples (6.2730.070) into openings 4, 6 and 8. The titration vessel lid is attached to the stand support (6.2001.070) using opening 10, fixed at the required height with the clamping ring and the horizontal brace of the stand support is mounted on the 815 with the socket head screw. 6.2730.030 stopper 10 6.2730.080 screw nipple 6.2730.070 screw nipple 1 2 3 3-way stopper 6.21543.210 8 9 4 6.2740.020 rinsing nozzle 7 6 5 6.2730.020 septum stopper Numbers and connections on the titration vessel lid (6.1414.060) The M8 PTFE aspiration tip (6.1543.170, supplied with 815) is inserted in opening 1 and connected to membrane pump 2 of the 815 with the M8 PTFE tubing (6.1805.510). The rinsing nozzle (6.2740.020, supplied with 815) is inserted into opening 2, which is connected to membrane pump 1 of the 815 with the FEP tubing (6.1805.060, supp. with 815). The buret tip (6.1543.200, supplied with 807) is inserted through opening 3 and will be connected to the connection set (6.5620.000, see next page), port 4 of the 50 ml Dosing Unit (LQH) with the 60 cm FEP tubing connection (6.1805.060, supplied with 815). This is where the ph electrode will later be inserted. The rinsing nozzle (6.2740.020, supplied with 815) is inserted into opening 5, which is connected to membrane pump 1 of the 815 with the FEP tubing connection (6.1805.060). The septum stopper (6.2730.020) (without upper screw and septum) and the screw nipple (6.2730.070) are pushed/screwed into opening 6. Then the 3-way stopper (6.1543.210) is inserted. The 3 connectors are connected to port 1 of the three Dosing Units 10 ml (EDTA), 20 ml (Auxiliary complexing solution) and 20 ml (0.1 M HCl) with three 40 cm FEP tubing connections (6.1805.100, supplied with 807 Dosing Units). The rinsing nozzle (6.2740.020, supplied with 815) is inserted into opening 7, which is connected to membrane pump 1 of the 815 with the FEP tubing connection (6.1805.060). This is where the Ca-ISE (6.0508.110) will later be inserted. This is where the 802 Rod Stirrer will later be inserted.

Page 8/16 4.2 Installation of the 50 ml Dosing Unit 6.5620.000 Luer: Port 4 6.1805.030 Port 3 6.2744.070 Port 1 6.2744.080 M6: Port 2 6.1803.020 6.1805.110 Connections on the bottoms of the 50 ml Dosing Unit Port 1 is used for emptying the Dosing Unit into the waste canister. Port 2 is used by the 50 ml Dosing Unit for taking in the sample via the titration arm. Port 3 is used for sample transfer to the IC system. The transition from M6 to the IC screw size (1/16 in.) is achieved with the 6.2744.080 adapter. Port 4 is used for the 50 ml Dosing Unit. This requires a coupling between Luer and M6: The PEEK connection (6.5620.000) is attached to the Luer connection on the bottom of the Dosing Unit. The 60cm M6 FEP tubing can be directly connected to the Luer/M6 adapter to realize «liquid handling» to the external cell. Once the tubing connections have been made, the Dosing Units are attached to the Dosino holder (6.2055.100) with the screw attachment and the distance ring of the Connecting Set for Dosing Unit (6.5620.000).

Page 9/16 4.3 Overview of all the tubing connections 6.1805.060 6.1805.510 6.1805.110 Metrohm Metrohm 6.1543.080 6.1805.030 800 Dosino 6.1805.100 6.1805.060 6.1803.020 800 Dosino 20 ml VENT 10 ml VENT Metrohm 800 Dosino Metrohm 800 Dosino Ace ac EDTA 50 ml 20 ml VENT VENT 0.1 M HCl 809 Titrando 815 712 6.2055.100 Overview of the tubing connections in the TitrIC 1 System

Page 10/16 The three 60 cm FEP tubing connections (6.1850.060, supplied with 815) are used to connect membrane pump 1 of the 815 and the three rinsing nozzles (6.2740.020, supplied with 815) to openings 2, 5 and 7 of the external cell (see page 7). The 60 cm M8 PTFE tubing connection (6.1805.510, supplied with 815) is used to connect membrane pump 2 of the 815 and the M8 PTFE aspiration tip (6.1543.170, supplied with 815) to opening 1 of the external cell (see page 7). The aspiration tip (6.1543.080) is attached by a stopper (6.2730.030) to the titration head (6.1462.070). The 80 cm FEP tubing connection (6.1850.110, supplied with 815) is used to connect the aspiration tip (6.1543.080) at the titration head (6.1462.070) and port 2 of the 50 ml Dosing Unit. The three 40 cm FEP tubing connection (6.1850.100, supplied with 807) are used to connect port 1 of the 10 ml (EDTA) and the two 20 ml Dosing Units (HCl / Auxiliary complexing solution) with the three connectors of the 3-way stopper at opening 6 of the external cell (see page 7). The 60 cm FEP tubing connection (6.1850.060) is used to connect port 4 of the 50 ml Dosing Unit and the buret tip (6.1543.200, supplied with 807) in opening 3 of the external cell (see page 7).. A suitable length of the 0.97 mm PTFE capillary (6.1803.020, supplied with 861) is used to connect port 3 of the 50 ml Dosing Units (using the screws 6.2744.080 and 6.2744.070) and the injection valves of the 861 Advanced Compact IC (position 1). The four 150 cm FEP tubing connections (6.1805.030) are connected to port 1 of the 50 ml Dosing Units, as well as port 3 of the two 20 ml and the 10 ml Dosing Units; all four tubing connections are then connected to the 10 L PE waste canister (6.1621.000).

Page 11/16 5 Miscellaneous 5.1 Stirrer The 802 Rod Stirrer is inserted through opening 9 of the external cell (see page 7) and connected to the tower of the 815. The propeller (6.1909.020) is pushed on from below. Connect the stirrer to the connector at the left of membrane pump 2 of the 815. 5.2 Length of the aspiration tips in the external cell Clamp the titration vessel (6.1415.220) to the titration vessel lid (6.1414.060). The M8 aspiration tip in opening 1 must reach right to the base of the titration vessel as this is the only way to ensure that the external cell is cleaned properly. The buret tips of the 3-way stopper in opening 6 and the buret tip of opening 3 should reach the middle of the titration vessel. The three tubings of the 3-way stopper have to be mounted with Antidiffusion micro valves to ensure a precise titration. 5.3 Electrodes The ph electrode (Aquatrode Plus with Pt 1000; 6.0257.000) is inserted into opening 4 together with the SGJ sleeve (6.1236.050). The cable is connected to the 809 Titrando at Input 2. The plug of the gray cable is connected to the opening marked Ind.. The red plugs with the adapters 6.2103.140 and 6.2103.130 are inserted in the openings marked Temp. If the electrode is not to be used for some time then it should be returned to its holder and kept in the storage solution (6.2323.000). The Ca-ISE (Polymer membrane electrode Ca, 6.0508.110) is connected to the electrode cable (6.2104.020) and inserted into opening 8. The cable is connected to the 809 Titrando at Input 1. The plug of the gray cable is connected to the opening marked Ind.. The red plugs with the adapters 6.2103.140 and 6.2103.130 are inserted in the openings marked Temp.. To have a reference electrode for the Ca-ISE one can short-circuit the reference channel of the Ca-ISE with the one of the Auquatrode. Thereto connect Ref. of Input 1 with Ref. of Input 2 with the electrode cable 2x plug B (6.2106.020). Conductivity cell (6.0912.110): The measuring cell cable is led through the guide chain of the 815 and the two black plugs are inserted into the openings marked Cond. Cell of 712 Conductometer, the two red plugs into those marked Pt 100/1000. Later (as soon as the titration head has been mounted) the measuring cell with the SGJ sleeve (6.1236.050) will be inserted in the SGJ 14 opening of the titration head.

Page 12/16 6 Software 6.1 Installation of the software Edgeport driver installation (Inside Out NETWORKS-CD): Connect the Edgeport with the USB cable (included in 2.145.0320) with the PC and then insert the CD. It s not necessary to start windows update, click on automatic installation of the software. tiamo 1.1 installation (tiamo-cd): All the standard directories proposed by the program should be accepted. IC Net 2.3 installation (Metrodata-CD): All the standard directories proposed by the program should be accepted. Restart windows. TitrIC 1.0 installation (Metrodata-CD): TitrIC 1.0 must only be installed after tiamo 1.1 and IC Net 2.3 have already been installed. After installation the standard TitrIC directory can be found under C:\Programme\ Metrohm\TitrIC, the TitrIC.exe file under C:\Programme\Metrohm\tiamo\bin. All programs must be shut down! 6.2 Configuration of tiamo The Controller cable (6.2151.000), which is already connected to the 809, is now connected to an USB interface on the PC. Wait a few seconds. The driver installation for 809 and 815 follows. It s not necessary to start windows update, click on automatic installation of the software for both. Switch on the 712 Conductometer tiamo 1.1 is started 6.2.1 Devices Connected devices are automatically recognized when tiamo is started. After confirmation of the automatically generated request the devices are stored in the configuration, keep the proposed device names. The 712 Conductometer is not recognized automatically and must therefore be added with the name 712_1 via Configuration / Devices / Edit / New / Meter / 712 Conductometer, as well as selected COM 5 under the entry RS 232 and confirmed with <OK>. Depending on the PC, the Edgeport port 1 could be assigned to a different COM port. This is checked by clicking on Start / System control / System / Hardware / Device manager / Connections (COM and LPT) and checking which COM port has been assigned to port 1 of the Edgeport. 6.2.2 Swing Head configuration Under Configuration at the top left, double-click on 815_1 under Devices, click on the entry Tower 1, set the Axial distance to 196.0 mm and in the middle of the window under Swing Head click on Configuration and Yes and then enter the following values: Configuration of the Swing Head for Titration head 6.1462.050 Confirm the entries twice with <OK> and then mark 815_1 under Devices and click on Edit / Initialize. Wait a few seconds. The titration head (6.1462.070) can now be mounted on the Swing Head.

Page 13/16 6.2.3 Special beaker definition Under Configuration mark 815_1, select Edit / Properties / Rack / Rack data / Special beaker, Special beaker 1, click on Edit and define the position to be used for rinsing as Rack position. The last position is normally used as the rinsing position. A sample vessel containing DI water should always stand in this position. Confirm by clicking on <OK> twice. 6.2.4 Lift positions Under Configuration / Tools / Manual operation click on 815 Sample Changer / Tower 1 in the left-hand column and use the entries Move and Assign position (See 815 Instructions for Use, page 47) to define suitable values (click on <Assign> each time) for: Shift position for changing the rack position (approx. 53 mm) Work position for aspirating of the sample (approx. 173 mm) Special position for dipping for the conductivity measurement (approx. 130 mm) For the special position you must define the work position again, then at the right beside Work position click on Tower and select Special position 1. Confirm these settings with a click on close. 6.2.5 Solutions The solutions to be used must, as usual, be defined in tiamo. Connect the Dosino of the 50 ml Dosing Unit to MSB 1 of the 809, the Dosino of the 20 ml Dosing Unit (HCl) to MSB 2 of the 809, the Dosino of the 10 ml Dosing Unit (EDTA) to MSB 3 of the 809 and the Dosino of the 20 ml Dosing Unit (Auxiliary complexing solution) to MSB 4 of the 809. The user is automatically requested to save the solutions click on <Yes>. In order to ensure compatibility with the methods provided, they must be named as described below. At the left click on Configuration, then at the top right under Titrants / Solutions double-click on the appropriate (empty) entries and enter the following under Solution name and Concentration: Configuration table for titrants / solutions Now the tubing lengths and ports are defined for each Dosing Unit under Edit / Properties / Dosing unit as follows: Dosing Port Prep/ Empty anion HCl EDTA Auxiliary complexing sol Port Length Port Length Port Length Port Length Special Port - Dosing Port 1 - Dosing Port 1 - Dosing Port 1 - Dosing Port 1 Port 4 60 cm Port 1 40 cm Port 1 40 cm Port 1 40 cm Dosing Port 2 Port 3 0 cm Port 3 0 cm Port 3 0 cm Port 3 0 cm Fill Port Port 2 80 cm Port 2 25cm Port 2 25 cm Port 2 25 cm Special Port Port 1 0 cm Port 4 0 cm Port 4 0 cm Port 4 0 cm Configuration table of the four Dosing Units

Page 14/16 6.2.6 Electrodes ph electrode: Under Configuration/Sensors click on Edit / New / ph electrode and enter under Sensor name Aquatrode Plus, type in the desired sensor information (e.g. serial number) and click on <Ok>. Ca-ISE: Under Configuration/Sensors double click on the entry ISE electrode and type in the desired sensor information (e.g. serial number) and click on <Ok>. Conductivity sensor: Under Configuration / Sensors click on Edit / New / other sensor and enter under Sensor name Conductivity sensor type in the desired sensor information and click on <Ok>. 6.2.7 Methods The following seven methods are provided: TitrIC 1 - complete run: With this method all the parameters possible with the standard instruments are measured and the IC measurement is initiated. TitrIC 1 - titration and measurement: Only titrations and direct measurements are carried out; the IC measurement is not initiated. In TitrIC under Settings / IC Net settings the IC Anions and IC Cations have to be deactivated, or the method is started up only from tiamo. TitrIC 1 - preparation of titration equipment: This method is used for preparing all titration instruments, i.e., rinsing the tubing connections of the Dosing Units with reagents or deionized water and rinsing the external cell. Start this method only from tiamo not from TitrIC! TitrIC 1 - IC calibration: This method is used for calibrating the IC measurement with standard solutions without having to carry out the titration part of a typical TitrIC measurement; this means that a lot of solution can be saved. TitrIC 1 semi automated ph calibration: With this method the ph electrode is calibrated automated; the buffer solutions are poored into the titration vessel. Start this method only from tiamo not from TitrIC! TitrIC 1 - ph calibration: Here the Aquatrode is taken out of the titration vessel and placed into the buffer solutions. Start this method only from tiamo! TitrIC 1 - titer determination of EDTA: This method is used for the titer determination. Start this method only from tiamo! TitrIC 1 - titer determination of HCl: This method is used for the titer determination. Start this method only from tiamo! An automated conductivity cell calibration method for tiamo can be delivered if desired (titric@metrohm.com); it is recommend to do it manually. Import: Click on Method at the left, then select under File / Method manager / Edit / Import in the directory C:\Program Files\Metrohm\tiamo\methods_titric all methods and click on <Open>. Note! Alterations of these methods should only be carried out by a person at the Administrator level and who is thoroughly familiar with tiamo. Never forget that in TitrIC this new method must be selected in the sample table under Methods tiamo.

Page 15/16 6.2.8 Configuration of the export template Export template: tiamo must transfer its results to TitrIC in a particular way, which means that the export template must be generated exactly in the following form: Under Database / Tools/ Templates / Export templates / New enter the following: then click on Select fields and enter the following: Configuration of the export template in TitrIC 1 Input window for the export template The entry Start counter is obtained at the left by clicking on Determination / Identification, ID1.Name and ID1.value are obtained at the left by clicking on Sample / Identifications, RS0x by clicking on Results / RS0xxx. By clicking on the upper double arrow in the center the entries can be moved to the right. Of course another number of results than five is possible. Shut down tiamo 1.1!

Page 16/16 6.3 Configuration of IC Net Start IC Net 2.3 Under Options / Global Preferences the following must be marked: under If method changed - Don t ask to save and System file overwrite - Always. With the TitrIC software a predefined IC system is also installed. It s found under C:\Program Files\Metrohm\IC Net 2.3\IC Net\Systems\Anion\anion.smt and C:\Program Files\Metrohm\IC Net 2.3\IC Net\Systems\Cation\cation.smt. Open the two systems, click on Control / Connect to workplace and choose the right COM-Port. If you don t know to which COM-Ports the systems are connected to you have to try out until you have communication between PC and the 861. Work should always be carried out with these systems, as otherwise the result transfer to TitrIC will be disturbed. This is why, if the systems have to be altered, the existing system is always altered and saved under the same name. The suppressor step is not made at the start of the measurement in the usual way, but with Fill directly after the end of the chromatogram. These means that after long pauses between measurements the suppression may no longer function. This is why after longer pauses you should carry out a suppressor step manually and ensure that the injection valve is in the Fill position. Depending on the application and column it may be necessary to adapt the time program in the IC system: Inject should always be carried out right at the start (0.10 min) of the time program, Fill right at the end. In this way you can start to measure with a stable baseline immediately after the sample loop has been filled by the Dosino. If a calibration is carried out later and the new calibration data are to be applied to a sample that has already been measured then this is possible by using TitrIC see the online help of the TitrIC software under Database / Recalculate / Recalculate for the results of several samples. Shut down IC Net 2.3 6.4 Configuration of TitrIC TitrIC is started (tiamo and IC Net are started automatically at the same time) All paths have already been entered as defaults and the system is ready for work. If other paths have been used instead of the default paths then this must be altered in the corresponding dialog under Workplace / Settings /. TitrIC starts tiamo and IC Net at the same time. However, the tiamo window is not visible, but can be brought to the foreground in TitrIC via View / Show tiamo. If TitrIC is shut down then tiamo will also be shut down automatically but IC Net must always be shut down individually. Always shut down TitrIC as the first program! If tiamo is accidentally shut down first then TitrIC is also no longer visible; the program will continue to run in the background. It can then be shut down with a right-hand click on an empty position in the Taskbar and a left-hand click on Task manager / Processes / TitrIC.exe / End process. For further information please consult the TitrIC online help (? / Show Help) or contact the responsible person at your local Metrohm agency. You can also report your problems to the following support email: titric@metrohm.com. Always start and shut down TitrIC first!