TM251MESE. Main. [Us] rated supply voltage. 14 with remote I/O architecture W with max number of I/O expansion module

Similar documents
TM251MESC controller M251 Ethernet CAN

TM251MESC controller M251 Ethernet CAN

TM241CE24T controller M IO transistor PNP Ethernet

TM241CE40T controller M IO transistor PNP Ethernet

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

TM241CE40R controller M IO relay Ethernet

TM241CE24U controller M IO transistor NPN Ethernet

TM241CE24T controller M IO transistor PNP Ethernet

TM241CE40R controller M IO relay Ethernet

TM241CE24T controller M IO transistor PNP Ethernet

TM241CE40R controller M IO relay Ethernet

TM241CE40R controller M IO relay Ethernet

TM241CEC24R controller M IO relay Ethernet CAN master

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input

TM241C40U controller M IO transistor NPN

TM241C24T controller M IO transistor PNP

TM241C40R controller M IO relay

TM221CE40R controller M IO relay Ethernet

TM221M16R controller M IO relay

TM221ME32TK controller M IO transistor PNP Ethernet

TM221CE40T controller M IO transistor PNP Ethernet

TM221ME16RG. Main. Discrete output number. Discrete input current

TM221CE24R controller M IO relay Ethernet

TM221CE40R controller M IO relay Ethernet

TM221CE24T. Main. Discrete output logic. Discrete input current. <= 7 relay output

TM221ME16T controller M IO transistor PNP Ethernet

TM221CE24T controller M IO transistor PNP Ethernet

TM221ME16T controller M IO transistor PNP Ethernet

TM221M16TG controller M IO transistor PNP spring

TM221M32TK controller M IO transistor PNP

TM200C24R controller M IO relay

TM200CE24T controller M IO transistor Source+ Ethernet

TM3DI16G module TM3-16 inputs spring

TM258LF42DT compact base M I/O - 24 V DC - CANopen

TM3TI4 module TM3-4 inputs temperature

TM221C40R controller M IO relay

TM3AI4 module TM3-4 analog inputs

TM3DI16 module TM3-16 inputs

TM258LD42DT4L compact base M I/O - 24 V DC

TM3TI8T module TM3-8 inputs temperature

TM3TI4 module TM3-4 inputs temperature

LMC058LF42 compact base - 42 I/O - 24 V DC supply

TM258LF42DT compact base M I/O - 24 V DC - CANopen

LMC058LF42 compact base - 42 I/O - 24 V DC supply

TM3TM3 module TM3-2 temperature inputs and 1 analog output

TM258LD42DT4L compact base M I/O - 24 V DC

TM258LF42DT compact base M I/O - 24 V DC - CANopen

TM238LFDC24DT. Main. Discrete output voltage. Discrete input voltage type. Number of I/O expansion module 7 [Us] rated supply voltage

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

TM3DI8A module TM3-8 inputs 120V AC

TM238LDD24DT compact base M I/O - 24 V DC supply -

TM238LFDC24DT compact base M I/O - 24 V DC supply - CANOpen - internal RAM 1000 kb

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

HMISCU6B5. Main. 60 right 40 top 60 bottom

TM3DM8R module TM3-8 IO relays

TM238LFAC24DR compact base M I/O V AC supply - CANOpen- internal RAM 1000 kb

TM3SAF. Main. Device short name

TWDLCAE40DRF. Main. Range of product

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

HMISCU6A5. Main. 60 right 40 top 60 bottom

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

TM221ME16TG controller M IO transistor PNP Ethernet spring

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

TWDLCAE40DRF compact PLC base Twido V AC supply - 24 I 24 V DC - 16 O

TM221M16R controller M IO relay

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

TM221CE40T controller M IO transistor PNP Ethernet

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

TM3SAK. Main. Device short name

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box

HMISCU6A5 3 5 color touch controller panel - Dig 16 inputs/10 outputs

TWDLCDA40DRF compact PLC base Twido - 24 V DC supply - 24 I 24 V DC - 16 O

HMISCU8A5 5 7 color touch controller panel - Dig 16 inputs/10 outputs

TM221CE16T controller M IO transistor PNP Ethernet

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

ZBRN1. Main. Device short name

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RE9RA21MW7 off-delay timing relay s V AC -

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

HMIGTO6310 advanced touchscreen panel 800 x 600 pixels SVGA- 12.1" TFT - 96 MB

XBTGT2120 advanced touchscreen panel x 240 pixels QVGA - 5.7" - 24 V

TWDLMDA20DRT extendable PLC base Twido 24 V - 12 I 24 V DC - 8 O solid state and relay

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

TWDLCAA16DRF. Main. Range of product

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

HMIGTO5310 advanced touchscreen panel 640 x 480 pixels VGA- 10.4" TFT - 96 MB

XBTGT1335 advanced touchscreen panel x 240 pixels QVGA - 3.8" - TFT LCD - 24 V DC

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

XBTGT4340 advanced touchscreen panel x2 40 pixels QVGA - 7.5" - 24 V

XBTGT6330 advanced touchscreen panel x 600 pixels SVGA " - TFT LCD - 24 V DC

HMIGTO2300. Main. External source. Chinese (simplified Chinese) Japanese (ANK, Kanji) Korean Taiwanese (traditional Chinese)

HMIGK5310 Keypad-touchscreen panel color x 480 pixels VGA -10.4" - TFT LCD

XBTGT6340 advanced touchscreen panel x 600 pixels SVGA " - 24 V

TWDLMDA40DUK extendable PLC base Twido 24 V - 24 I 24 V DC - 16 O solid state

TWDLCDA16DRF compact PLC base Twido - 24 V DC supply - 9 I 24 V DC - 7 O relay

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

XBTGC2330T 5 7 LCD TFT color controller panel - 16 inputs/16 outputs source

Transcription:

Product datasheet Characteristics TM251MESE Main Range of product Product or component type [Us] rated supply voltage Modicon M251 Logic controller 24 V DC Complementary Number of I/O expansion module Supply voltage limits Inrush current Power consumption in W Memory capacity Data backed up Data storage equipment Battery type Backup time Execution time for 1 KInstruction 7 with local I/O architecture 14 with remote I/O architecture 20.4...28.8 V <= 50 A Execution time per instruction 0.022 µs Application structure Realtime clock Clock drift Integrated connection type Supply Transmission rate Communication port protocol Port Ethernet Web services Communication service 32.6...40.4 W with max number of I/O expansion module 8 MB program 64 MB system memory RAM 128 MB built-in flash memory backup of user programs <= 32 GB SD card optional BR2032 lithium non-rechargeable, battery life: 4 yr 2 years at 77 F (25 C) 0.3 ms event and periodic task 0.7 ms other instruction 8 event tasks 4 cyclic master tasks 3 cyclic master tasks + 1 freewheeling task 8 external event tasks With <= 60 s/month at 77 F (25 C) USB port with mini B USB 2.0 connector Non isolated serial link "serial" with RJ45 connector; physical interface: RS232/RS485 Dual-port "Ethernet 1" with RJ45 connector Ethernet port "Ethernet 2" with RJ45 connector 5 V at 200 ma serial link supply with "serial" marking 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m - communication protocol: RS485 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 9.84 ft (3 m) - communication protocol: RS232 480 Mbit/s for bus length of 9.84 ft (3 m) - communication protocol: USB USB port - USB protocol ; transmission frame: SoMachine-Network Non isolated serial link - Modbus protocol ; transmission frame: RTU/ASCII or SoMachine-Network with master/slave method "Ethernet 1" marking 10BASE-T/100BASE-TX - 2 port copper cable "Ethernet 2" marking 10BASE-T/100BASE-TX - 1 port copper cable Web server FDR Downloading IEC VAR ACCESS Modbus TCP client Modbus TCP server Modbus TCP slave device The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. 1 / 5

Maximum number of connections Number of slave Cycle time Local signalling Electrical connection Insulation Marking Monitoring NGVL Programming Updating firmware SMS notifications DHCP client (Eth1) DHCP server (Eth2) Ethernet/IP originator (Eth2) Ethernet/IP target (Eth1, Eth2) Ethernet/IP scanner (Eth2) Modbus TCP I/O Scanner and Messaging (Eth2) SNMP client/server FTP client/server SQL client Send and receive email from the controller based on TCP/UDP library Web server (WebVisu & XWeb system) OPC UA server DNS client 8 Modbus server 8 Modbus client 16 Ethernet/IP target 4 FTP server 10 web server 8 SoMachine protocol 16 Ethernet/IP 64 Modbus TCP 64 ms with 64 slave(s) on Modbus TCP 10 ms with 16 slave(s) on Ethernet/IP 1 LED red module error (ERR) 1 LED green PWR 1 LED green RUN 1 LED green SD card access (SD) 1 LED red BAT 1 LED green SL 1 LED red I/O error (I/O) 1 LED red bus fault on TM4 (TM4) 1 LED green Ethernet activity (ETH1) 1 LED green Ethernet activity (ETH2) Removable screw terminal block power supply with pitch 5.08 mm adjustment Non-insulated between supply and internal logic Between supply and ground at 500 V AC CE Surge withstand 1 kv (shielded cable) with common mode protection conforming to EN/IEC 61000-4- 5 1 kv (power lines) with common mode protection conforming to EN/IEC 61000-4-5 0.5 kv (power lines) with differential mode protection conforming to EN/IEC 61000-4- 5 Mounting support Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 rail conforming to IEC 60715 Plate or panel with fixing kit Height Depth Width Product weight 3.54 in (90 mm) 3.74 in (95 mm) 2.13 in (54 mm) 0.49 lb(us) (0.22 kg) Environment standards UL 508 CSA C22.2 No 142 ANSI/ISA 12-12-01 UL 1604 CSA C22.2 No 213 EN/IEC 61131-2 : 2007 Marine specification (LR, ABS, DNV, GL) product certifications CSA CULus resistance to electrostatic discharge 4 kv (on contact) conforming to EN/IEC 61000-4-2 8 kv (in air) conforming to EN/IEC 61000-4-2 resistance to electromagnetic fields 9.14 V/yd (10 V/m) (80 MHz...1 GHz) conforming to EN/IEC 61000-4-3 2.74 V/yd (3 V/m) (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3 0.91 V/yd (1 V/m) (2 GHz...3 GHz) conforming to EN/IEC 61000-4-3 2 / 5

resistance to fast transients 2 kv (power lines) conforming to EN/IEC 61000-4-4 1 kv (Ethernet line) conforming to EN/IEC 61000-4-4 1 kv (serial link) conforming to EN/IEC 61000-4-4 resistance to conducted disturbances 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6 3 V (0.1...80 MHz) conforming to Marine specification (LR, ABS, DNV, GL) 10 V (spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)) conforming to Marine specification (LR, ABS, DNV, GL) electromagnetic emission immunity to microbreaks ambient air temperature for operation ambient air temperature for storage relative humidity IP degree of protection pollution degree 2 Conducted emissions - test level: 120...69 dbµv/m QP (power lines) at 10...150 khz Conducted emissions - test level: 63 dbμv/m QP (power lines) at 1.5...30 MHz Radiated emissions - test level: 40 dbμv/m QP class A (10 m) at 30...230 MHz Conducted emissions - test level: 79...63 dbμv/m QP (power lines) at 150...1500 khz Radiated emissions - test level: 47 dbμv/m QP class A (10 m) at 230...1000 MHz 10 ms 14...131 F (-10...55 C) horizontal installation -10...35 C vertical installation -13...158 F (-25...70 C) 10...95 % without condensation in operation 10...95 % without condensation in storage IP20 with protective cover in place operating altitude 0...6561.68 ft (0...2000 m) storage altitude 0...9842.52 ft (0...3000 m) vibration resistance shock resistance 3.5 mm at 5...8.4 Hz on symmetrical rail 3 gn at 8.4...150 Hz on symmetrical rail 3.5 mm at 5...8.4 Hz on panel mounting 3 gn at 8.4...150 Hz on panel mounting 15 gn during 11 ms Offer Sustainability Green Premium product Compliant - since 1350 - Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Green Premium product Compliant - since 1350 - Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Dimensions Clearance 3 / 5

Mounting Position NOTE: Keep adequate spacing for proper ventilation and to maintain an ambient temperature between -10 C (14 F) and 55 C (131 F). Acceptable Mounting NOTE: Expansion modules must be mounted above the controller. Incorrect Mounting Direct Mounting on a Panel Surface 4 / 5

USB Connection to a PC Ethernet Connection to a PC 5 / 5