Installation, Operation and Maintenance Manual

Similar documents
Table of Contents Product Overview Before using the product Installation Procedure... 5

MAXIMA+ Series Rotary Level Indicator

Mitsubishi Electric Automation Instruction Manual FR-A5AC-01

MAXIMA + Series ROTARY LEVEL CONTROL

SED2 Variable Frequency Drives

P216 Series Condenser Fan Speed Controller

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

List of contents. 7-2 CE (ENC EN55022) declaration of conformity CE (LVD EN60950) declaration of conformity. 15 發行章

PV Rapid Shutdown device

SA-150, SA-300 Series Pure Sine Wave Inverter User s Manual

S66 Series Electronic Fan Speed Control

Instruction Manual (Supplementary) Totally-Enclosed Box Type Inverter

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Table of Contents. Safety. Attention. Warnings

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

H Manual Stretch Wrap Machine uline.com FILM ROLL CAPACITY TECHNICAL DATA ELECTRICAL SPECIFICATIONS TURNTABLE SPECIFICATIONS

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

PG Softstarter Installation Manual for 5A, 9A and 16A Controllers

EX-RC1 Remote I/O Adapter

1395 Node Adapter Board Troubleshooting

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ETM MD100 Drive System 1/2HP (370W) User Manual. Table of Contents. Drive Features

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

Operating instructions. Speed monitor D / / 2014

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

User Manual. Solar Inverter for Water Pump

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

Rotork Fairchild PAX1 Linear Actuator User s Manual

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ACCESS 9340/9360 Meter Input/Output Module

ELV12 Series. Instruction Manual

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017

P216. Condenser fan speed controller. Product bulletin. Features

Service Instructions. Conductor 420

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

V E62B Snap-in I/O Module

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT SAFETY NOTICE...

AD-7830 Servo Amplifier

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

SECTION VARIABLE FREQUENCY DRIVES

BCM2 Series Branch Circuit Monitors Quick Setup Guide

Model 2657A-LIM-3 LO Interconnect Module

Operating instructions. Switching amplifier DN0210 DN / / 2015

Industrial motor controller for brushed DC motors 24 VDC

EX-RC1 Remote I/O Adapter

Smartstart Control Module

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Voltage Current Front-mounting bracket

PM Series Power Meter

Model 7705 Control Module

Installation Instructions

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

DC I/O Conversion Module FA-TB32XY

Version 1.9. Reference for Part Numbers: EQUBE-P EQUBE-N EQUBE-AI-P

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

ASI Systems ML5740A Series

ASI Systems ML5720A Series

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

SAVE THESE INSTRUCTIONS

SmartVFD Disconnect Panel Assemblies

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

CFM-9225V XX - CXX

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

OPLC Installation Guide

VSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override

UPS READY POWER DISTRIBUTION ASSEMBLY

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112

P2-04AD Analog Input. Removable Terminal Block Specifications

OPC-VG1-PG / PGo. PG Interface Card for FRENIC-VG. Instruction Manual

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

P2-04DA Analog Output. Removable Terminal Block Specifications

MAXIMA + Series ROTARY LEVEL CONTROL

PFC Mini TM Power Factor Corrected AC-DC Switchers

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Zenith DS9000 Dispensing System

Easy To Use OEMS Take Note

DC I/O Conversion Module

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

PowerFlex 400 AC Drive Guide Specification

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Transcription:

Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with these instructions will result in voiding of the product warranty and may result in personal injury and/or property damage. General Information The Vari-Green Drive (VGD) is a factory mounted and wired variable frequency drive. It is compatible with induction and permanent magnet motors. It is programmed at the factory to match the characteristics of the fan and motor on which it is installed. Safety Instructions As with all electrical products, read the manual thoroughly before operating. Only qualified personnel should perform maintenance and installation. Do not disassemble or repair unit. Death or injury due to electrical shock may result. To prevent injury and property damage, follow instructions during installation and operation of the VGD. Incorrect operation of the VGD due to ignoring these instructions may cause harm and damage. This manual should be placed in a location where it can be accessed by the users of this product and by those that are responsible for its maintenance. WARNING Do not remove VGD cover for wiring or periodic inspections while power is applied or the unit is in operation. Otherwise, electric shock could occur from the exposed terminals and bus bars. Wait at least 1 minute after disconnecting the input power and also verify all LEDs including the Power and Charge LEDs are off before performing any wiring tasks and/or periodic inspections on the VGD. Operate VGD and control devices with dry hands. Otherwise, electric shock could occur. Do not use VGD if power or motor cable is damaged. CAUTION Disconnect the input power if VGD has been damaged. Otherwise, fire and secondary damage or accidents could occur. Do not touch VGD immediately after shutting down or disconnecting it. It can remain hot for a few minutes. Otherwise, bodily injuries such as skin-burn or damage could occur. Do not apply power to a damaged VGD or to VGD with missing parts. Do not allow lint, paper, wood chips, dust, metallic chips or other foreign material into the drive. Otherwise, fire or accident could occur. Vari-Green Drive 1

Table of Contents General Information.... 1 Features.... 2 Physical Overview.... 2 Startup Procedure.... 3 Programming.... 4 First Application of Power.... 4 Operation Notes.... 4 Troubleshooting....5-6 Maintenance.... 6 Precautions.... 6 Periodic Inspection.... 6 Specifications.... 6 Features Model 100 Speed control options: On-Board Dial 0-10VDC signal 4-20mA signal Other Vari-Green Controls Power, Run, Fault LEDs 24VDC @ 0.5A damper actuator power output 24VDC @ 50mA control power output for Vari-Green Controls Motor Protection Thermal Overload, Over Voltage, Under Voltage, Input Phase Loss, Over Current, Overheat, Short Circuit, Hardware Error, Cooling Fan Failure R 3 Filtering Helps meet IEEE 519 without an external line reactor or filter. VGD Physical Overview Diagram EMI Jumper (J4) Power Input R S T U V W A+ A- 24 ON 1 2 Control Wiring Terminal Block Motor Output Analog Dip Switch 2 Vari-Green Drive

Startup Procedure Power Wiring The Vari-Green Drive power input and output connections are pre-wired at the factory. Refer to local electrical codes for branch circuit protection and proper wiring size and type. EMI Jumper (J4): The Vari-Green Drive comes from the factory with a jumper installed that connects the EMI filter to earth ground. This jumper must be removed if the Vari-Green Drive is installed on a corner grounded power system. Note: For Part Number 385817, 385818 The VGD requires class J or K fuses size 20A or smaller to provide short circuit protection on the input. If a fused disconnect was not supplied by Greenheck, fuses must be provided by others. Control Wiring There are five terminals on the control board for connecting input signals and powering/signaling a damper. Terminal Label Purpose +24VDC Power, 0.5A Max. On when VGD is A+ commanding motor to run. Useful for powering appropriate damper actuator. A- -24VDC Power. Ground for A+ terminal. 24 +24VDC power, 50mA Max. Used to power Vari-Green controls. On when VGD is powered. Analog input signal (configurable via ANALOG dip switches) Signal Ground for analog input For Part Number 386168, 386169, 386221, 386222, the VGD has internal fuse protection and does not require a fused disconnect. Speed Control Option Wiring Connections VGD Ex. Device Analog Dip Switch Settings Notes 24 RED ON 1 2 On-Board Dial WHITE BLACK 1: ON 2: On-board Dial Part Number 384588 24 ON 1 2 1: 0-10VDC Signal 0-10VDC 2-10V Active Range GROUND 2: 24 1: ON ON 1 2 4-20mA Signal 4-20mA 4-20mA Active Range GROUND 2: ON 24 24V POWER ON 1 2 Other Vari-Green controls 0-10V SIGNAL COMMON/ GROUND 1: 2: Refer to control manual wiring diagram for connections to control Vari-Green Drive 3

Motorized Backdraft Damper Connect 24VDC motorized backdraft damper to the A+ and A- terminals. Make sure amp draw of actuator does not exceed 0.5A. The VGD will energize the damper actuator when given a Run command. After the VGD is commanded to run, there will be a time delay to let the damper open before the motor starts accelerating. If an actuator of a different voltage or amp draw is used, this power source can be used to energize an interposing relay. Programming No field programming or configuration is possible with the VGD 100 model. All motor and fan information has been set at the factory and is not adjustable. EXAMPLE OF PARAMETERS THAT HAVE BEEN FACTORY SET: Motor Voltage Motor Speed Motor FLA Acceleration/Deceleration Time Min/Max Frequency Note: If the motor is changed to a motor with a different voltage, speed or FLA the VGD must be replaced as well. First Application of Power Warning: Ensure fan is properly installed and the rotating parts can freely rotate. Loose tools, parts and clothing must be secured before starting fan. Stay clear of rotating shafts, belts and pulleys. 1. Apply the proper input voltage to the VGD after all wiring connections have been made. 2. Provide the drive with a run command (rotate dial clockwise or provide a control signal greater than 2VDC or 4mA). 3. Check rotation of fan to ensure it matches the rotation direction label on the fan. The rotation should be factory set. a. If incorrect, disconnect and lock-out power, then swap any two of the three leads between the VGD and motor Note: Swapping leads on the input of the VGD will have no effect on rotation. 4. Slowly ramp fan to full speed and make sure no faults are present and the fan is operating smoothly. Operation Notes LED Status There are three LEDs on the front cover. - Power The power LED is green when power is applied to the VGD. - Run The run LED is solid green when the VGD is running the motor and drawing current. The run LED will be flashing green if a run command is present but the drive does not sense motor current. - Fault The fault LED will flash red when a fault has occurred. See the Troubleshooting section for fault details. On-Board Dial Rotate the dial clockwise to increase fan speed and counterclockwise to decrease fan speed. Rotating the dial full counterclockwise will cause the fan to stop. 0-10V input The fan will operate from 2-10VDC. 2V is minimum speed and 10V is maximum speed. 0-1.9V the fan will be off. 4-20mA input The fan will operate between 4-20mA. 4mA is minimum speed and 20mA is maximum speed. From 0-4mA the fan will be off. Vari-Green Controls Refer to specific Vari-Green Control instruction manual for operational details. Belt Drive Fans Where the Vari-Green Drive is installed on a belt drive fan, the belt/pulley sizes have been selected for a fan RPM that corresponds to the max RPM for the motor size that was ordered when the VGD is running at max frequency. Note: The design fan RPM may be less than the maximum fan RPM. Warning: Replacing the belts/pulleys with a combination that increases the fan speed may overload the motor/vgd and cause a fault. Never exceed the maximum fan RPM. 4 Vari-Green Drive

Troubleshooting Faults When a fault is present, the VGD turns off its motor output and flashes the Fault LED. Each fault is associated with a certain number of blinks. The LED will blink for 0.5 second for each blink followed by a 2 second break. The number of 0.5 second blinks indicates the fault present. Number of LED Blinks LED Blink Fault Fault # Fault 1 Thermal Overload 2 Motor Overcurrent 1 Overcurrent 3 Overcurrent 5 Output Phase Open 9 PM Motor Sync Fault 2 Over Voltage 6 Over Voltage 3 VGD Overheat 10 VGD Overheat 7 Under Voltage 4 Under Voltage 8 Input Phase Open 5 VGD Short Circuit 4 VGD Short Circuit 6 Cooling Fan Failure 12 Cooling Fan Failure 7 Damper 13 Limit Switch Failed to Close 14 Damper Power Over Current 8 HW Fault 16 Hardware Failure 9 Comms loss 11 Lost Communication LED States Run LED Fault LED Description VFD is off and there are no faults ON VFD is running and there are no faults Blinking Fault blink sequence Run command present with no proof of flow VFD is off with Fault Protective Function Thermal Overload Overcurrent VFD Short Circuit Output Phase Open Over Voltage Under Voltage Input Phase Open Cause This fault occurs if current is within the inverse trip curve for motor rated current class of 10 and service factor of 1.15. A fault occurs when output current is continuously above the trip current threshold multiplied by the rated Current (per VGD UL Label) for a time greater than the trip time. A fault occurs when short circuit is detected on the output terminals of the VGD. A fault occurs when the output phase current of one phase is less than or equal to the average of the two remaining phases by the specified percentage Instantaneous Over Voltage: A fault occurs when DC Bus voltage is greater than or equal to 800VDC for 400V model and 400VDC for the 240V model. A fault occurs when DC Bus voltage is less than internal setting (that corresponds to 90% of the lowest rated input voltage (200V or 400V) for 2 seconds (continuous) A fault occurs when any one of the input phases is disconnected. Remedy Make sure fan speed is not over maximum for motor size Check if rotor is locked and/or mechanical obstructions to motor/fan Check motor wiring and windings Conduct a mechanical inspection on the system Frequent starting with this fault may damage the VGD power components Check output wiring Check motor wiring Check output wiring Ensure motor is properly connected to VGD Check line voltage and call utility company Check line voltage Check fuses Check input wiring Check input power Check fuses Vari-Green Drive 5

General Troubleshooting Symptom Possible Causes Possible Solution VGD does not operate fan Speed range is incorrect Cooling fan failure fault No control input signal Ensure proper voltage/current is measured on the Terminal Analog dip switch settings incorrect Verify dip switch matches proper control signal (pg. 3) Analog dip switch settings incorrect Verify dip switch matches proper control signal (pg. 3) Cooling fan unplugged/not functioning Check cooling fan Maintenance The Vari-Green Drive is an industrial electronic product with advanced semiconductor components and its operation depends on installation and operation conditions such as temperature, humidity, vibration, dust, etc. It is recommended to perform routine inspections of all operating VGD s in addition to the maintenance recommended in the fan s instruction manual. Precautions Remove input power while performing maintenance procedures. Use a True RMS Multimeter to ensure voltage is not present at the output terminals. Other types of voltmeters cannot read high frequency PWM output voltage correctly. Periodic Inspection Check for loose connections, bolts, nuts or rust buildup caused by surrounding conditions. Check for any discoloration or visual damage to the various connectors inside the VGD. Call Greenheck for support if any discolored or damaged connectors are found. Ensure heat sink fins underneath the VGD are free of obstructions and debris. 6 Vari-Green Drive

Specifications VGD Model 100 Output Ratings SPECIFICATIONS Part Numbers 385817 385818 386221 386222 386168 386169 Voltage 0-240 VAC 0-480 VAC 0-240 VAC 0-480 VAC 0-240 VAC 0-480 VAC Max motor FLA 8.0A 6.0A 8.0A 6.0A 16.0A 14.0A Frequency*: 15-240 Hz Yes Yes Yes Yes Yes Yes Phase 3 3 3 3 3 3 Voltage (+15%/-10%) 200-240 VAC 380-480 VAC 200-240 VAC 380-480 VAC 200-240 VAC 380-480 VAC Certifications Environment Operation Input Ratings Frequency: 50/60 Hz (±5%) Yes Yes Yes Yes Yes Yes Phase 3 3 3 3 3 3 Efficiency, full load 96% 98% 96% 98% 96% 98% Power Factor 0.9 0.85 0.9 0.85 0.9 0.85 % THD (Meets IEEE 519) 32.0 32.0 32.0 32.0 32.0 32.0 On Board Fuses No No Yes Yes Yes Yes Analog Input 0-10V, 0-24V, 4-20mA Yes Yes Yes Yes Yes Yes (selectable via DIP switch) Damper Actuator Output 24VDC, 0.5A Max Yes Yes Yes Yes Yes Yes Control Voltage Output 24VDC, 50mA Max Yes Yes Yes Yes Yes Yes 3LEDs: Power, Run, Fault Yes Yes Yes Yes Yes Yes Max Ambient Temperature 40ºC (104ºF) 40ºC (104ºF) 40ºC (104ºF) 40ºC (104ºF) 40ºC (104ºF) 40ºC (104ºF) Storage Temperature Relative Humidity (Non-condensing) Up to 95% RH Up to 95% RH Up to 95% RH Up to 95% RH Up to 95% RH Up to 95% RH Agency Approvals UL Listed E223975 Yes Yes Yes Yes Yes Yes Enclosure Rating Type 4/IP66 Type 4/IP66 Type 4/IP66 Type 4/IP66 Type 4/IP66 Type 4/IP66 EMC Directive 2014/35/EU Yes Yes No No No No Wire Sizes and Terminal Lugs VFD rating 200-240VAC 380-480VAC Terminals Input Power Terminal Motor Power Terminal All Control Terminals Screw Size Metric Screw Torque kgf. cm lbf.in Nm Conductor Size AWG / kcmil mm2 M4 23.04 20 2.26 10~18 5.3~0.82 M4 23.04 20 2.26 10~18 5.3~0.82 M2.6 4.55 3.98 0.4 14~26 0.2 ~ 2.5 Vari-Green Drive 7

Our Commitment As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Product warranties can be found online at Greenheck.com, either on the specific product page or in the literature section of the website at Greenheck.com/Resources/Library/Literature. Phone: 715.359.6171 Fax: 715.355.2399 Parts: 800.355.5354 E-mail: gfcinfo@greenheck.com Website: www.greenheck.com 8 481200 Vari-Green Drive, Rev. 3, October 2018 Copyright 2018 Greenheck Fan Corporation