w w w. p r o l i g h t. c o. u k TRI PAR 64 Order code: LEDJ48 - Black Order code: LEDJ49 - Polished USER MANUAL

Similar documents
w w w. p r o l i g h t. c o. u k Quad Par 64 (Order code: LEDJ46 - Black) (Order code: LEDJ47 - Polished) USER MANUAL

w w w. p r o l i g h t. c o. u k STAGE PAR 64

order code: EQLED40 user manual

Order code: EQLED60 USER MANUAL

LEDJ Tri LED DJ Skirt Matrix Cloth - STAR17 USER MANUAL

Colour Burst Order code: LEDJ01 USER MANUAL

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

User Manual Equinox 2m Flight Cased DMX LED Flame Machine Order code: FLAM12

LIGHT BRICK - 12 X 3W TRI-COLOUR

Order code: EQLED53 User manual

Professional DMX Stage Backdrop

Microbar COB System. User Manual. Order code: EQLED137

IMPACT Order code: EQLED79

CDP 405 Digital Dimmer Pack

UV Spectra Batten 12 x 5W UV LEDs

UV Power Flood. User Manual. Order code: EQLED029

Blitzer Strobe. User Manual. Order code: EQLED366

Crossfire. User Manual. Order code: EQLED061

Performer 18 HEX. 18 x 12W 6-in-1 colour LEDs (RGBWAUV) User Manual. Order code: LEDJ252B

Performer 18 RGBWA MKII

Slimline CW & WW Series

RGB Power Batten. User Manual. Order code: EQLED032

Fusion Razor Beam. 3 x 12W Moving Head User Manual. Order code: EQLED006

Fusion Saber. User Manual. Order code: EQLED070

Blitzer RGB Strobe. User Manual. Order code: EQLED365

CS2 DMX Distribution Splitter

Vector Beam White. User Manual. Order code: LEDJ265

DMX LED Starcloth Systems

MICRON DJ Booth Tri-colour Starcloth

HEX Par 9 MKII. Exterior Fixture User Manual. Order code: LEDJ226

Gobo Projector XP 80W

Alu HEX Par 64. (12 x 12W six-colour LEDs RGBWAUV) User Manual. Order code: ELUM114

EasiLED 4 DMX Controller

Microbar Multi System

PF LED Profile. User Manual

MICRON DJ Booth System with Overhead Kit & CW Starcloth

ZF LED Zoom Fresnel. User Manual

Saturn Spot. User Manual. Order code: EQLED023

Vortex. User Manual. Order code: EQLED073

Intense 9P10 RGBWA LED Slim Par

Endura 1Q120 RGBW COB Exterior Fixture

Hypnos. User Manual. Order code: EQLED372

Intense 9HEX10 LED Slim Par

Slimline 12Q5 Series

Flexoled FTP3HP RGB LED DMX Driver

Fresco 24 RGBW. Exterior Fixture User Manual. Order code: LEDJ267

FTP1 Single Channel LED DMX Driver

TRANSCENSION Show Control

order code: EQLA04 user manual

50W/100W LED Alu. User Manual. Code: ELUM041-50W - (5600K) Code: ELUM041A - 100W (5600K) Code: ELUM041C - 50W - (3200K) Code: ELUM041D - 100W (3200K)

User Instructions. American DJ

SP-1500 DMX MK II Strobe

TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Connections 6.

Octostrip ORDERCODE 42220

CPA 40 Two Channel Amplifier

Party Dimmer IEC ORDERCODE 50324

Flat Par 9 LEDs. battery power, Wirelss, Remote Control, RGBWA-UV 6-in-1 USER MANUAL. Please read over this manual before operating the light

LED PAR56 Order Code: P56-151

Multidim ORDERCODE 50391

Starlit Dance Floor. User Manual

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

Light Brick ORDERCODE 50370

D-Pack 6 Classic ORDERCODE 50315

MA V 30W Mixer Amplifier Order code: CRAM02 MA V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL

Robot Light V2. User Manual

1 Channel Strobe Controller ORDERCODE 40226

LED Par 64 Short DMX ORDERCODE 42431

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

Heavy Duty DMX Mirror Ball Rotator with Safety Eye

LED DANCING FLOOR User Manual

LED Dancefloor ORDERCODE 42300

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

Antenna Distributor ORDERCODE D1444

Showdesigner 512 ORDERCODE 50721

RGBW Mini Moving Head Stage Spot Light Model: SSL1. User Manual.

LED MOVING HEAD FLEX BEAM K8 RGBW. User Manual. Please read the instruction carefully before use

TourPro RGBAW Stagebar USER MANUAL

COLOR PAR 56 COLOR PAR 64. User Manual Please read the instructions carefully before use. Широкий ассортимент оборудования ACME на

1 Channel Sliding Profile Dimmer ORDERCODE 50425

LED W RGBA User Manual

Colour Star Sky I DMX ORDERCODE 40341

MATRIX LED LED User Manual Please read the instructions carefully before use

LED Accu Penta 9x12W RGBWAU

Kameleon series RGB 3 in one USER MANUAL

FLEX BEAM V8. User Manual Please read the instruction carefully before use

STAGE TRI-PAR 18TC CP-18TC. User Manual. Please read the instructions carefully before use

CP 64 BD15 CP 64 PD15

Power LED Beam 56 Narrow

Cobra Dimmer Master DMX Controller User Manual

StagePar COB TRI 4 CKU

User Manual Please read the instructions carefully before use

User Manual INTRODUCTION SAFETY INFORMATION BACK PANEL DIAGRAM. Please read the instructions carefully and before use.

FUSION SPOT MKII EQUINOX. Contents. User Manual. Order codes: Black housing - EQLED Safety Instructions. 2. Features & Specifications

LED BEAM MOVING HEAD FL x3W User Manual

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

LED Slimline PAR RGBW 7x8W

KasBar COB Tri 5. 5x15w 3in1 COB LEDs (RGB) USER MANUAL

LED BEAM MOVING HEAD 12x12W Cree, 4in1, beam 8 degree

Warning... Safety-instructions Operating Determinations Rigging... Description... Features and Overview...

Kam StarWash Multicolour wash effects with green & red star cluster laser

Transcription:

w w w. p r o l i g h t. c o. u k TRI PAR 64 Order code: LEDJ48 - Black Order code: LEDJ49 - Polished USER MANUAL

Safety WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! CAUTION! Keep this equipment away from rain, moisture and liquids. SAFETY INSTRUCTIONS Every person involved with the installation, operation & maintenance of this equipment should: - Be competent - Follow the instructions of this manual CAUTION! TAKE CARE USING THIS EQUIPMENT! HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!! Before your initial start-up, please make sure that there is no damage caused during transportation. Should there be any, consult your dealer and do not use the equipment. To maintain the equipment in good working condition and to ensure safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this manual. Please note that damages caused by user modifications to this equipment are not subject to warranty.

Safety IMPORTANT: The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment. Never let the power-cable come into contact with other cables. Handle the power-cable and all mains voltage connections with particular caution! Never remove warning or informative labels from the equipment. Do not open the equipment and do not modify the equipment. Do not connect this equipment to a dimmer-pack. Do not switch the equipment on and off in short intervals, as this will reduce the system s life. Only use the equipment indoors. Do not expose to flammable sources, liquids or gases. Always disconnect the power from the mains when equipment is not in use or before cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the power-cable. Make sure that the available voltage is between 220v/240v. Make sure that the power-cable is never crimped or damaged. Check the equipment and the power-cable periodically. If the equipment is dropped or damaged, disconnect the mains power supply immediately. Have a qualified engineer inspect the equipment before operating again. If the equipment has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation might damage the equipment. Leave the equipment switched off until it has reached room temperature. If your product fails to function correctly, discontinue use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Prolight dealer for service. Only use fuses of same type and rating. Repairs, servicing and power connection must only be carried out by a qualified technician. THIS UNIT CONTAINS NO USER SERVICEABLE PARTS. WARRANTY; One year from date of purchase. OPERATING DETERMINATIONS If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and the warranty becomes void. Incorrect operation may lead to danger e.g.: short-circuit, burns, electric shocks, lamp failure etc. Do not endanger your own safety and the safety of others! Incorrect installation or use can cause serious damage to people and property.

Technical specifications You should find inside the LEDJ carton the following items: 1, Tri Par 64 Unit 2, Instruction manual Technical Specifications: 400Hz flicker free 3W LEDs Voltage: AC 240 ~ 50Hz 18 Ultra bright 3W Tri colour LED Power Consumption: 60W Dimensions: 310 x 230 x 220mm Weight: 2.8Kgs Operating modes: 1, Static Colour mode 2, Auto Run mode 3, Colour Fade mode 4, Sound Active mode 5, Master/Slave mode 6, DMX channels: 6 Overview: 3 7 5 8 1, DMX output 2, DMX input 3, LED display 4, Fuse (2A) 5, Mode selection button 6, Up button 7, Down button 8, Enter button 1 6 2 4

Operation Operation: There are 6 different operation modes to choose from: 1) Static colour mode 2) Colour change mode 3) Colour fade mode 4) Sound active mode 5) DMX mode 6) Slave mode 1, Static colour mode Mode button - Press the MODE button under the LED display, to show C000, then press the ENTER button to choose one of the static colours using the UP and DOWN buttons. The C1 represents Red, C2 = Green, C3 = Blue and CF = strobe. The two digits after it are the brightness 00 to 99 or in CF they are the strobe speed. Examples: If you set C1, C2 and C3 to zero, the Tri Par will have no LEDs on (blackout). If you set C1 to 99 and C2 and C3 to zero, the Tri Par will be 100% Red. NOTE: For static selection of Red, Green, and Blue, ensure that the unwanted colours are set to 00. 2, Colour change mode Mode button - Press the MODE button until the LED display shows J000, then press the ENTER button to choose one of the colour changing modes using the UP and DOWN buttons. The colour change programmes are as follows: 1, J300 = RGB, 2, J700 = 7 colour, 3, JF00 = Strobe, Now press the ENTER button again and you can then select the colour change speed using the UP and DOWN buttons. The speed settings are from 00-99 (00 = slow, 99 = fast) 3, Colour fade mode Mode button - Press the MODE button until the LED display shows F000, then press the ENTER button to choose one of the colour fading modes using the UP and DOWN buttons. The colour fade programmes are as follows: 1, F300 = RGB, 2, F700 = 7 colour, 3, FF00 = Strobe, Now press the ENTER button again and you can then select the colour fade speed using the UP and DOWN buttons. The speed settings are from 00-99 (00 = slow, 99 = fast) 4, Sound active Mode button - Press the MODE button until the LED display shows S000, then press the ENTER button to choose one of the sound active modes using the UP and DOWN buttons. 1, S300 = RGB, 2, S700 = 7 colour The sensitivity levels range from 00-99 (00 = low, 99 = high)

Operation 5, DMX Addressing mode To access the DMX address mode, press the MODE button until the LED display shows A001, then follow the DMX channel assignment and function table overleaf. 6. Master/Slave mode Link the units together using a 3-pin DMX cable, then press the MODE button to select one of the above modes. On the Slave units press the mode button until the LED display shows SLAV. The Slave units will then follow in sequence with the Master unit. 6 Channel DMX chart Channel 1 2 3 4 5 6 Value 000-255 000-255 000-255 000-255 0-4 5-84 85-169 170-255 0-255 Function Master dimmer Red (0-100%) Green (0-100%) Blue (0-100%) No function Colour micro Colour jump Colour fade Strobe

DMX Set up DMX-512: DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures (most controllers only have a data out terminal). DMX Linking: DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all fixtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain. DATA Cable (DMX cable) requirements (for DMX operation): The Tri Par 64 can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. Your unit and your DMX controller require a standard 3-pin XLR connector for data input/ output (figure 1). Figure 1 Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight dealers. Please quote: CABL10 2M CABL11 5M CABL12 10M Also remember that DMX cable must be daisy chained and cannot be split.

DMX Set up Notice: Be sure to follow figures 2 & 3 when making your own cables. Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing. Grounding the shield could cause a short circuit and erratic behaviour. Special Note: Line termination: When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behaviour. Termination reduces signal transmission problems and interferance. it is always advisable to connect a DMX terminal, (resistance 120 Ohm 1/4 W) between pin 2 (DMX-) and pin 3 (DMX+) of the last fixture. Using a cable terminator (part number CABL90) will decrease the possibilities of erratic behaviour. 5-Pin XLR DMX Connectors: Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-Pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be used. The Chart below details the correct cable conversion.