CPCI System Subrack 1 U

Similar documents
CPCI System Subrack 3 U

CPCI System Subrack 3 U

3+1 U CPCI Serial System

3/4 U CPCI Serial Case System

VME64x System Subrack 1 U

VME64x System Subrack 8 U

VME System Subracks 3 U / 4 U

CPCI PSB System Subrack 10 U

VME Subrack System 7 U

VME System Subracks 7 U / 8 U

CPCI/CPCI Serial Hybrid System 3+1 U

User's Manual CPCI Basic 3U, 30HP CPCI Basic 3,5U, 42HP

CPCI Basic 1U, 2U and 4U User's Manual

CPCI-PS24 24V-Power Supply

User's Manual CPCI Basic 4U, 63HP PXI Basic 4U, 63HP

VME64x Basic 1U, 2U and 4U User's Manual

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

User's Manual CPCI Basic 3U and 6U, 84HP VPX Basic 4U, 84HP Fan Tray 1U, 84HP

MC 11 EB-2 Power supply cabinet with external bus, AC version

LVN5200A-R2, rev. 1, Hardware Installation Guide

Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide

Operating Instructions

Installation Job Aid for Ethernet Routing Switch 3600 Series

Preparing to Install the VG248

Voltage Current Front-mounting bracket

Junos WebApp Secure 5.0 Hardware Guide

Installation Job Aid for Ethernet Routing Switch 5900 Series

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

vme, vme64x, vxs, vpx

Power supply CP-C 24/5.0

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

TABLE OF CONTENTS 1. OVERVIEW... 1

Model 2380 Rack-Mount Kit

Redundancy unit CP-A RU

FMP VDC RECTIFIER 42 Amps 2000 Watts

Dell MD1280 Storage Enclosure Getting Started Guide

CMC III Temperature/Humidity Sensor

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

MODEL 805 USER MANUAL

MIC-3002A Series. 3U 6-slot CompactPCI Enclosures with Rear I/O and 6" LCD. User Manual

CMC III Universal Sensor

Metro-Optical Transport Access Nodes

General-Purpose 8-Slot Chassis for PXI

TRC-190 User s Manual

FMPe30.48G 48VDC RECTIFIER 60 Amps 2900 Watts

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

NI PXI-1042 Series Power Supply Shuttle

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

Switch Mode Power Supply S8VT 120/240/480/960 W Models

MIC-3001/8. 3U/4U CompactPCI Enclosure for Rack Mounting. User Manual

EthernetConnect and IP/Analog Fiber Accessories POWER SUPPLIES, RACK CHASSIS WITH INTERNAL POWER SUPPLY

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

1U MTCA Shelf. User s Manual. Product Number: /025

Ripac VME/VME64x Systems. Applications. Design Features

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

1 Airflow via normal convection or forced-air cooling devices in the enclosure or housing outside of the subrack.

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

RTU500 series Data Sheet Power Supply CP-E 24/2.5

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Dell Networking S4810 Open Networking (ON) Getting Started Guide

Europacpro Industrial Applications

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

Installing and Managing the Switch

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION RD-48 LV/HV. RS-422/485 Repeater Répéteur RS-422/485

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

CompactPCI SYSTEM POWER SUPPLIES. CPCI SERIES 150 to 350 Watts, Ac Input with PFC DPCI SERIES 150 to 350 Watts, 48 Vdc Input FEATURES:

4170 POS System Installation Guide

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

Industrial Power Supplies

Industrial Power Supplies

MINI-PS AC/10-15DC/8

AO523 Analog Input Module

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Operating instructions. Switching amplifier DN0210 DN / / 2015

PHOENIX CONTACT - 07/2006

3190 Series Touch Screen POS Workstation

Operating instructions. Speed monitor D / / 2014

SIM-9106/9303 High Current Switching Mode Power Supply with C.C., C.V., Remote Control & Sensing User Manual

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Switching Power Supplies

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

E-Series Site Preparation Guide

PACSystems RX7i IC698CHS009/119

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Rhino PSM Power Supplies. Operating Instructions

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

VFI RTG PDU 6-10K. Installation and user manual. Service and support: Call your local service representative

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Transcription:

User s Manual Product No.: Doc-No: 63972-165_R1.0 January 14, 2008

Rev. Date updated Change R1.0 January 14, 2008 Initial Release Impressum: Schroff GmbH D-75334 Straubenhardt, Germany The details in this manual have been carefully compiled and checked - supported by certified Quality Management System to EN ISO 9001/2000 The company cannot accept any liability for errors or misprints. The company reserves the right to amendments of technical specifications due to further development and improvement of products. Copyright 2008 All rights and technical modifications reserved.

Table of Contents 1 Safety... 1 1.1 Intended Application... 1 1.2 Safety Instructions... 2 1.2.1 Safety Symbols used in this document... 2 1.3 General Safety Precautions... 2 2 Product Definition... 3 2.1 References and Architecture Specifications... 3 2.2 Subrack System Overview... 3 2.3 Subrack:... 4 2.4 CPCI Backplane... 4 2.5 Power Supply... 5 2.5.1 Grounding/Earthing... 5 2.5.2 CPCI Plug-In AC Power Supply (Order separately)... 6 2.6 Cooling... 7 3 Installation... 8 3.1 General Installation Guidelines... 8 3.1.1 Unpacking... 8 3.1.2 Ensuring Proper Airflow... 8 3.2 Rack-Mounting... 9 3.3 Initial Operation... 9 4 Service... 10 4.1 Technical support and Return for Service Assistance... 10 4.2 Declaration of Conformity... 10 4.3 Scope of Delivery... 11 4.4 Accessories... 11 4.5 Spare Parts... 11 5 Technical Data... 12 6 Dimensions... 13 www.schroff.biz I R1.0, January 14, 2008

www.schroff.biz II R1.0, January 14, 2008

Safety 1 Safety 1.1 Intended Application The CompactPCI (CPCI) system subrack, described in this manual, is intended as a platform for a microcomputer system based on the CompactPCI Standard PICMG 2.0 Rev.3. The CPCI system subracks are designed for protection class IP 20 and can be used only in the resp. environments. For higher protection requirements, e.g. IP 54/55 you must install the system subrack in a protective case. CPCI system subracks are not end-products, so there is no valid approval for this unit. In order to enable stand-alone functionality, additional elements are required. An operational system is achieved only by way of appropiate CPCI boards. The completion and final testing of the units have been carried out, or at least supervised, by qualified technicians. These instructions are directed exclusively to these qualified technicians i.e.engineers, trained and qualified electricians etc. Make sure that: the finished system complies with the safety regulations currently applicable in the country it is going to be used. the finished system complies with all other regulations and specifications at the place and country of use, e.g. interference limits, approval by the telecommunications authorities. www.schroff.biz 1 R1.0, January 14, 2008

Safety 1.2 Safety Instructions The intended audience of this User s Manual is system integrators and hardware/software engineers. 1.2.1 Safety Symbols used in this document Hazardous voltage! This is the electrical hazard symbol. Familiarise yourself with the danger of electrical voltages and the safety precautions to avoid accidents before starting to work with parts that carry dangerous voltages. Caution! This is the user caution symbol. It indicates a condition where damage of the equipment or injury of the service personnel could occur. To reduce the risk of damage or injury, follow all steps or procedures as instructed. Danger of electrostatic discharge! Static electricity can damage sensitive components in a system. To avoid damage, wear ESD wrist straps or at regular intervals touch blank enclosure parts. 1.3 General Safety Precautions Warning! Voltages over 60 VDC can be present in this equipment. This equipment is intended to be accessed, to be installed and maintained by qualified and trained service personnel only. This equipment is designed in accordance with protection class 1! It must therefore be operated only with protective GND/earth connection! Service personnel must know the necessary electrical safety, wiring and connection practices for installing this equipment in a telecommunication environment. Install this equipment only in compliance with local and national electrical codes. www.schroff.biz 2 R1.0, January 14, 2008

CPCI System Subrack 1 U Product Definition 2 Product Definition The Schroff CPCI system subrack consists of: A shielded 19 subrack with front and rear card cage for 6 U boards according to CompactPCI Standard PICMG 2.0 Rev.3 A 6 U 2 slot CPCI Backplane, system slot left (bottom) A slot for an optional CPCI plug-in power supply (250 W) Fans for the active cooling of the boards Power input module with IEC 320-C14 connector, mains/line switch, mains/ line filter and fuses 2.1 References and Architecture Specifications User Manual CPCI Backplanes Order no.: 73972-101 Technical Data Schroff CPCI Backplanes 23006-7xx Order no.: 73972-088 User Guide Schroff CPCI Backplanes 23006-794 Order no.: 63972-213 Further information can also be found in the catalogue Electronic Packaging and on the internet under www.schroff.biz 2.2 Subrack System Overview Figure 1: Subrack System Overview 12308805 www.schroff.biz 1 Front Card Cage 4 Rear Card cage with guide rails 2 Fan Tray 5 Power Input Module 3 Top Cover 6 Power Supply (optional) 3 R1.0, January 14, 2008

Product Definition 2.3 Subrack: 2.4 CPCI Backplane The 1 U 19 subrack is based on the Schroff europacpro system with EMC shielding. The card cage enables the horizontal assembly of 2 CPCI front boards (6 U, 4 HP, 160 mm deep) and 2 Rear I/O Boards (6 U, 4 HP, 80 mm deep). The right guide rails of the board cage are equipped with ESD clips. The horizontally assembled 6 U Backplane provides: CompactPCI bus (PICMG2.0 R.3.0) with System Slot left (bottom) Connector for the Fan Tray at the left side 47-position CPCI power connector for the power supply at the right side Applicable Specifications: PICMG 2.0 R3.0 CPCI Core Specification PICMG 2.01 R2.0 Hot Swap PICMG 2.09 R1.0 System Management Bus PICMG 2.10 R1.0 Keying www.schroff.biz 4 R1.0, January 14, 2008

Product Definition 2.5 Power Supply Hazardous voltage! Parts of the power supply may be exposed with hazardous voltage. Always remove mains/line connector before carry out any assembly work. Caution! Your system has not been provided with a AC power cable. Purchase a AC power cable that is approved for use in your country. The AC power cable must be rated for the product and for the voltage and current marked on the product's electrical ratings label. The voltage and current rating of the cable should be greater than the ratings marked on the product. The CPCI system can be powered by a CPCI plug-in power supply with wide range input (100-240 VAC). The power supply is plugged-in in a dedicated slot at the right front side. The power supply contacts via a 47-position connector to the backplane. The power input is provided by a AC mains/line module with IEC 320-C14 connector, integrated mains/line fuses and line filter. The fuse rating is 4 A slow blow. Figure 2: AC Terminal - Grounding 1 Fuseholder 3 AC Connector (IEC320-C14) 2 Mains/line switch 4 6,3 mm faston connector 2.5.1 Grounding/Earthing 12308803 Caution! The unit is designed in accordance with protection class 1! It must therefore be operated with protective earth/gnd connection. Use only a three conductor AC power cable with a protective earth conductor that meets the IEC safety standards! There is a 6,3 mm faston connector at the rear panel. This connector is only for equipotential bonding. Grounding is achieved through the protective earth conductor of the power cable! www.schroff.biz 5 R1.0, January 14, 2008

Product Definition 2.5.2 CPCI Plug-In AC Power Supply (Order separately) Figure 3: Power Supply 10006814 Table 1: Data AC Power Supply e Input voltage nominal 100-240 VAC Mains Frequency Output (max.) 50 / 60 Hz 250 W Output voltages 3.3 5.0 12.0-12.0 Ripple < 1 % V V V V - - - - 40 40 5.5 2 A A A A Dynamic response Recovery time to within 1% Overvoltage protection Overcurrent protection Hold-up time < 1 % or 60 mv < 300 µsec for all voltages 120 130 % U > 5 Vr 105 130 % of rated output current >= 20 ms An 48 VDC power supply is available on request. www.schroff.biz 6 R1.0, January 14, 2008

Product Definition 2.6 Cooling Figure 4: Fan Tray 12308800 1 Backplane Connector The boards are cooled by forced air convection through four 12 VDC axial fans (13,5 m³/h (8 cfm) each). The operating temperature is from 0 C to 50 C, but note that the power supply starts derating at 50 C. Caution! To maintain proper airflow, all open slots must be covered with filler panels. The filler panel should include an airflow baffle that extends to backplane. Figure 5: Airflow 12308804 www.schroff.biz 7 R1.0, January 14, 2008

Installation 3 Installation 3.1 General Installation Guidelines 3.1.1 Unpacking Caution! When opening the shipping carton, use caution to avoid damaging the system. Consider the following when unpacking and storing the system: Leave the system packed until it is needed for immediate installation. After unpacking the system, save and store the packaging material in case the system must be returned. If the packaging is damaged and possible system damage is present, report to the shipper and analyze the damage. 3.1.2 Ensuring Proper Airflow Install the system in an open rack whenever possible. If installation in an enclosed rack is unavoidable, ensure that the rack has adequate ventilation. Maintain ambient airflow to ensure normal operation. If the airflow is blocked or restricted, or if the intake air is too warm, an over temperature condition can occur. Ensure that cables from other equipment do not obstruct the airflow through the systems. Use filler panels to cover all empty chassis slots. The filler panel prevents fan air from escaping out of the front of an open slot. Caution! To maintain proper airflow, all open slots must be covered with filler panels. The filler panel should include an airflow baffle that extends to backplane. www.schroff.biz 8 R1.0, January 14, 2008

Installation 3.2 Rack-Mounting This subrack system can be installed in 19 equipment racks. The rack must be accessible from the front and rear for equipment installation. Mounting Instructions: Ensure that the rack is constructed to support the weight and dimensions of the system. Install any stabilizers that came with your equipment rack before mounting or servicing the system in the rack. Load the rack from the bottom to the top, with the heaviest system at the bottom, avoid uneven mechanical loading of the rack. 3.3 Initial Operation Warning! Voltages over 60 VDC can be present in this equipment. This equipment is intended to be accessed, to be installed and maintained by qualified and trained service personnel only. This eqipment is designed in accordance with protection class 1! It must therefore be operated only with protective GND/earth connection! Ensure that the system has not been damaged during transport, storage or assembly. Check the Protective Earth (PE) resistance, should be < 0,1 Ohm. Switch on the system and check all CPCI voltages directly on the backplane connectors before the board assembly. Plug-in the boards Cover all open Slots with filler panels. www.schroff.biz 9 R1.0, January 14, 2008

Service 4 Service 4.1 Technical support and Return for Service Assistance We generally recommend to return the complete subrack system. For all product returns and support issues, please contact your Schroff sales distributor or www.schroff.biz. We recommend that you save the packing material. Shipping without the original packing material might void the warranty. 4.2 Declaration of Conformity SCHROFF CompactPCI system subracks are developed and manufactured according to EN 60950-1. SCHROFF CompactPCI system subracks are not end-products with independent functionality as described in the definition of the EMC regulations, and therefore a CE marking is not required. However, when CPCI cards are assembled according to specification, the systems fulfill the requirements in accordance with EMC Directive 2004/108/EG and Low-voltage Directive 2006/95/EG. Interference resistance and interference emissions are factors which are heavily influenced by the type and quantity of CPCI cards used in the system assembly. Through the use of high quality line filters and EMC optimized enclosure design, SCHROFF offers CPCI systems which serve as an ideal base for system integrators, which comply with the prescribed limits of EN 6100-6-3 and EN 61000-6-2 The systems are generally equipped with power supplies which possess CE markings in accordance with EN 60950-1, EN 61000-6-3, EN 61000-6-2). Before delivery a high-voltage, protective earth and functionality test is carried out on each individual system. www.schroff.biz 10 R1.0, January 14, 2008

Service 4.3 Scope of Delivery Quantity Description 1 19 subrack, shielded, black powder coated (RAL9005) 1 CPCI backplane (PICMG2.0 R.3.0), 2 slot 6 U, system slot left 1 Front card cage for max. 2 boards 6 U 160 mm deep IEEE guide rails inc. ESD clips (ESD clip assembled at the right) 1 Rear card cage for max. 2 boards 6 U 80 mm deep IEEE guide rails inc. ESD clips 1 Slot fo a CPCI plug-in power supply 1 Complete AC/DC cabling 1 Power input module with IEC 320-C14 connector, mains/line switch, mains/line filter and fuses 1 Fan Tray, hot swappable 4.4 Accessories Order No. Description 13100-141 250 W plug-in power supply with wide range input 20848-7xx 34562-8xx Slot covers with front panel and EMC shielding for vacant slots. For dimensions, please see catalogue. Slot covers for vacant slots. For dimensions, please see catalogue. 24579-03x Printed Circuit Board covers (perforated solder side covers). For dimensions, please see catalogue 4.5 Spare Parts On request. www.schroff.biz 11 R1.0, January 14, 2008

Technical Data 5 Technical Data Table 2: Technical Data Dimensions Height 44.45 mm (1U) Width 482.80 mm (19 ) Depth (Card cage) 275 mm Weight Depth (Overall with handles) 303 mm Completely assembled 5 kg Power Supply (order separately) Input Voltage 100 VAC bis 240 VAC Frequency 50 / 60 Hz Power input up to 250 W Cooling 4 x 12 VDC fans 13.5 m³/h (8 cfm) each, free blow Ambient Temperature Operation +0 C to +50 C Storage -40 C to +85 C Humidity Admissible humidity 30 % to 80 %, non-condensing EMC, fulfils requirements for: Transient Emissions EN 61000-6-3 Interference Resistance EN 61000-6-2 Safety Test voltages according to EN 60950 Input - Output: Input - PE: Output - PE: Output - Output: 4,3 kvdc 2,2 kvdc 0,7 kvdc 0,7 kvdc Shock and vibration: EN 60068-2-6 and EN 60068-2-27 Electromagnetic Shielding Shielding attenuation typ. 40 db at 1 GHz if shielded front panels are used. www.schroff.biz 12 R1.0, January 14, 2008

Dimensions 6 Dimensions Figure 6: Dimensions 42.0 465.20 482.80 283.25 304.70 13.95 10006858 www.schroff.biz 13 R1.0, January 14, 2008

Dimensions www.schroff.biz 14 R1.0, January 14, 2008

SCHROFF GMBH www.schroff.biz Langenalberstr. 96-100 Tel.: + 49 (0) 7082 794-0 Fax: +49 (0) 7082 794-200 D-75334 Straubenhardt