SMARTAISLE Intelligent, Integrated Infrastructure for the Data Center

Similar documents
SmartAisle Intelligent, Integrated Infrastructure Using Row-based Building Blocks. Solutions For Business-Critical Continuity

SMARTMOD Intelligent, Integrated Infrastructure for the Data Center

SmartMod Intelligent, Integrated Infrastructure for the Data Center

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

SmartRow Intelligent, Integrated Infrastructure in a Self-Contained Line-Up. Solutions For Business-Critical Continuity

Smart Solutions Intelligent, Integrated Infrastructure for the Data Center

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER

Liebert. HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

ARE YOUR RACK PDUS KEEPING YOU FROM OPTIMIZING POWER MANAGEMENT?

Liebert DCW CATALOGUE

Two-Stage Power Distribution: An Essential Strategy to Future Proof the Data Center

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Liebert. CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

CRITICAL INFRASTRUCTURE ASSESSMENTS

Optimize Your Data Center. Gary Hill VP, Business Development DVL Group, Inc.

ADDRESSING CHALLENGES TO POWERING SMALL TO MIDSIZE IT SPACES

VERTIV RACK PDUS. Power Perfectly Configured for Your IT Application

PLAYBOOK. How Do You Plan to Grow? Evaluating Your Critical Infrastructure Can Help Uncover the Right Strategy

SmartCabinet Intelligent, Integrated Containment for IT Infrastructure

THE NEW WORLD OF IT INFRASTRUCTURE SOLUTIONS. Enabling an IT Infrastructure as Dynamic as Your Business

Liebert APM UPS The Industry s Highest Energy Efficiency In A Row-Based, On-line UPS. AC Power For Business-Critical Continuity

INNOVATE FASTER COMPETING FOR THE IT WORKLOAD BUSINESS. Hosted Cloud, Managed Service Providers & Colocation Data Centers

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

APPLYING DATA CENTER INFRASTRUCTURE MANAGEMENT IN COLOCATION DATA CENTERS

Trellis Platform. for Data Center Infrastructure Management (DCIM)

2016 COOLING THE EDGE SURVEY. Conducted by Vertiv Publication Date: August 30, 2016

Liebert. PDX and PCW Compact Perimeter Cooling Solutions

PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

Liebert DSE Precision Cooling System Industry-best efficiency. Increased capacity. Ensured availability. EFFICIENCY. CAPACITY. AVAILABILITY.

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

Liebert. DCL up to 35 kw. Modular Rack Cooling

Aisle Containment Systems. Physical Containment Systems Selection Guide

Liebert. DSE Thermal Management System Free Cooling Economization Without Using Water

Liebert. DCL up to 35 kw. Modular Rack Cooling

APPLYING PROPER CABLE MANAGEMENT IN IT RACKS. A Guide For Planning, Deployment And Growth

Rack PDU Marketing Playbook

Liebert PDX. The Cooling Solution for Small and Medium Data Centers. Digital Scroll. Part Load. Competent Partner Efficiency

Liebert. EXS from 10 to 20 kw. Optimized and integrated three-phase UPS solution with high efficiency power protection

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers

THE CHALLENGES WITH A COLOCATION ROLL-OUT: And how to simplify the deployment and maintenance of IT equipment at the colocation facility

DATA CENTER TRANSFORMATION: THE IMPACT OF EMERGING POWER ARCHITECTURES ON TODAY S DATA CENTERS

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

DC POWER OVERVIEW BROCHURE Powerful Solutions for Critical Data and Telecom Applications

Liebert. PDX from 15 to 165 kw. Direct Expansion Solution for Small and Medium Data Centers

Liebert : The Right Cooling For IT Environments

TECHNOLOGY: THE COMPETITIVE ADVANTAGE FOR SUCCESSFUL RETAIL BUSINESS

Data Center Assessment Helps Keep Critical Equipment Operational. A White Paper from the Experts in Business-Critical Continuity TM

Liebert. NXC from 10 to 200 kw. Compact and Reliable Power in a Fully Integrated Packaged Solution

Liebert PDX from 15 to 120 kw

Precision Cooling. Precision Cooling Advantages

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

84 kw, Tier 3, Direct Expansion, 937 ft 2

CHANGING THE WAY COMPANIES RUN. The Aperture Suite

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

USING REST TO ACHIEVE FULL VISIBILITY AND CONTROL ACROSS THE INTERNET OF THINGS: INSIDE THE DATA CENTER ECOSYSTEM WITH TRUE CLOSED-LOOP CONTROL

SUPERSAVER. Energy Efficiency Optimization Software for Freecooling Systems

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

INNOVATE DESIGN APPLY.

Eaton 93PM: Value, Benefits, and Features Eaton. All Rights Reserved..

Liebert. AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability CERTIFIED HVAC-HYGIENE.

DATA CENTER PRECISION COOLING: The Need For A Higher Level Of Service Expertise

INNOVATE DESIGN APPLY.

THE NEW WORLD OF IT INFRASTRUCTURE SOLUTIONS. Enabling an IT Infrastructure as Dynamic as Your Business

POWER PRODUCTS AS INCLUDED IN OUR PLATINUM RESELLER, JEM TECH'S NY STATE CONTRACT

AVOCENT SOLUTIONS FOR THE BROADCAST CONTROL ROOM Driving Innovation in Omni-Platform Broadcasting

exm UPS 80kW - 200kW Efficient, Flexible Power Optimized For Medium Size UPS Applications

THE EDGE OF SIMPLICITY: INFRASTRUCTURE FOR DISTRIBUTED IT. Strategy, Solution and Services Guide

MEETING THE DCOI FEDERAL MANDATE. Achieving Rapid Compliance with the Trellis Platform

Liebert PDX from 15 to 120 kw

THE INSIDE-OUT APPROACH. Enabling an Open, Scalable Data Center IoT

Five Best Practices for Increasing Efficiency, Availability and Capacity: The Enterprise Data Center Design Guide

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Thermal management. Thermal management

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

Liebert XDA Air Flow Enhancer. User Manual

Liebert APM. The Compact, Row-Based UPS with Flexpower Technology 30kW - 300kW

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

Managed Rack PDU MPH2 More efficient Simpler Better

Virtualization and consolidation

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Energy Efficiency Solutions for Your Data Center

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

Solutions for Business-Critical Continuity. Emerson Network Power Technology and Solutions for a World in Action

Next Generation Cooling

Green IT and Green DC

Rack & Enclosure Systems

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

Total Modular Data Centre Solutions

Power and Cooling Design Guidelines for Network Access Rooms. A White Paper from the Experts in Business-Critical Continuity TM

Liebert. PCW from 25 to 220 kw. Chilled Water Units Optimizing Data Center Efficiency

Liebert exm UPS kva/kw Efficient, Flexible Power Optimized for Midsize Applications FLEXIBLE. ECONOMICAL. INTELLIGENT

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

Liebert. GXT3 5kVA-10kVA Compact UPS Systems For High Power Network Rack Applications

Transcription:

SMARTAISLE Intelligent, Integrated Infrastructure for the Data Center

SMARTAISLE Deploy an Efficient and Flexible Row-Based Infrastructure Efficiency. Capacity. Availability. Control. The SmartAisle infrastructure from Vertiv offers considerable savings in CAPEX and OPEX via an intelligent, integrated row-based system. The infrastructure integrates racks, power, cooling and infrastructure management into a holistic data center solution. With this solution, Vertiv has demonstrated CAPEX savings of 10 percent AND OPEX savings of 27%, as well as: ysimplified, rapid deployment that means that installation doesn t hinder productivity or break budgets yenhanced cooling efficiency with the Liebert CRV row-based precision cooling system, Liebert icom Controls and cold aisle containment combining to deliver PUEs 15-25% lower on average than that of a conventionally designed data center with the same capacity yindustry s highest efficiency UPS and power management systems with modular designs for easier scalability ycomprehensive visibility, insight and control via data center infrastructure management technologies ensure availability and efficiency when you need them most 1. High-efficiency precision cooling technologies and environmental controls Liebert CRV precision cooling system with Liebert icom controls matches cooling to rack load, and reduces cooling system energy consumption through: Digital scroll compressor EC plug fans Teamwork control modes 2. Modular, scalable highefficiency power Liebert APM UPS provides reliable, transformer-free, on-line, uninterrupted power, and KIRK key interlock system for safety 3. Flexible power distribution Liebert MB Modular Busway is a flexible and more economical way to deliver power to the rack without the cost and hassle of power cable whips. It connects directly to rack PDUs 4. Cold Aisle Containment inexpensively supports capacity increases by separating hot and cold air for increased efficiency 5. Flexible platform for easy configuration Full-depth DCF racks maximize space utilization and allow you add any type of IT or networking equipment and simplify cable management with tool-less accessories 6. Flexible rack PDUs MPX adaptive rack PDU or MPH2 managed rack PDU provide flexibility and power control at the receptacle level, and faster implementation of IT equipment 7. Comprehensive, remote data center infrastructure management Avocent appliances and software and Liebert Nform and Liebert SiteScan softwares provide comprehensive, remote monitoring and control 2

SmartAisle Simple, fully integrated infrastructure racks, precision cooling, monitoring, cable management and power systems are designed to work together, saving you time and money on installation and operation. 3

SMARTAISLE What Makes the SmartAisle Offering Unique? Imagine the advantages of an intelligent, integrated infrastructure with all the capabilities you need to achieve your IT objectives. The SmartAisle infrastructure utilizes these data center design and technology best practices to deliver the following results: 1. Maximizes the return temperature at the cooling units to improve capacity and efficiency 2. Matches cooling capacity with IT load 3. Utilizes cooling design that reduces energy consumption 4. Uses power management systems that optimize availability and efficiency 5. Features a design the enhances flexibility using scalable architectures that minimize footprint 6. Utilizes real-time infrastructure optimization to provision resources faster, increase efficiency and reduce stranded capacity 7. Leverages the availability of in-market data center design expertise and technical assistance EFFICIENT ECONOMICAL SIMPLIFIED CONTROLLABLE yreduce energy consumption up to 27% compared to conventional data center design through the use of Cold Aisle Containment, Liebert precision cooling systems, and Liebert icom controls yincrease availability by using high-efficiency power systems, such as Liebert APM UPS or Liebert GXT3 yimprove productivity and standardize equipment moves, adds and changes with monitoring and management technologies yachieve equipment cost savings and extend your existing infrastructure investment by using more efficient designs and technologies ysave up to 10% in capital expenditures using technologies that help you avoid expensive room upgrades to cooling systems, flooring and power management ysimplify design, implementation and reconfiguration using standardized, integrated systems yensure continuity of business operations with single system startup, warranty, preventive maintenance and repair yutilize industry-leading service and support provided by local data center design experts yfree up stranded capacity and gain efficiencies using Avocent Data Center Planner and Liebert SiteScan software ymaintain cooling equipment operating levels to ensure efficiency and availability, using Liebert icom controls y Monitor and manage power capacity within the rack, by using Liebert UPS systems and rack PDUs yflexibly and costeffectively distribute power to the rack using Liebert MB Modular Busway, compared to using a distribution cabinet. 4

Where to Use SmartAisle Infrastructure Solutions No Other Solution Offers the Industry s Leading Infrastructure Systems for Such a Wide Array of Applications and Environments SmartAisle configurations can be scaled to fit any size IT environment from a row of racks to large enterprise data centers. The SmartAisle offering brings together the widest range of innovative infrastructure technologies such as modular row-based UPS, configurable PDUs, modular busway, data center infrastructure management software and the industry s leading precision cooling technologies. The SmartAisle approach can be used as a standalone solution to scale from just a few racks up to an entire data center (most cost effective up to 400kW total load), with integrated row-based power, precision cooling and infrastructure management. Or within a larger data center, it can be applied to meet capacity growth objectives, providing the infrastructure support needed to increase density without increasing footprint. This highly efficient, flexible and easily implemented solution can be deployed in either raised floor or non-raised floor environments. A. James Clark School of Engineering at the University of Maryland Location: College Park, Maryland, USA. Critical Need: Optimize an existing data center infrastructure for efficiency, availability and space-utilization to promote availability and accommodate future IT growth. Vertiv was able to help the University of Maryland achieve Efficiency Without Compromise in revamping a 25-year-old data center into a modern infrastructure that is very efficient and will meet our growing capacity needs for the future. Products/Services: ycomprehensive Thermal Assessment with Computational Fluid Dynamics (CFD) Modeling ysmartaisle technologies, including Liebert CRV Row-Based Precision Cooling Solution with Liebert icom Controls and remote monitoring facilitated by Liebert s Virtual Ntegrity Gateway (VNG) Results ydoubled cooling capacity and physical capacity of data center yoptimized server configuration and airflow for maximum efficiency and IT availability yimproved Power Usage Effectiveness (PUE) by 5.5 percent Jim Zahniser, Executive Director of Information Technology, A. James Clark School of Engineering at the University of Maryland 1 A. James Clark School of Engineering at the University of Maryland Case Study. CH-00022 (05/11). 5

SMARTAISLE Economy and Efficiency Compare the Costs of a Conventional Data Center Design Versus the SmartAisle Infrastructure Solution CONVENTIONAL DATA CENTER DESIGN SMARTAISLE DESIGN COST SAVINGS ADVANTAGE SMARTAISLE Room Costs $515,000 $459,000 $56,000 11% Infrastructure Costs $415,000 $391,000 $24,000 6% Total Capital Expense $930,000 $850,000 $80,000 9% Energy Consumption $63,600 $46,500 $17,000 27% 5 Year OpEx $318,000 $233,000 $85,000 27% 5 Year TCO $1,248,000 $1,083,000 $165,000 13% CONVENTIONAL Racks 27 Density Total IT Load Cooling Units Power Precision Cooling AC Power 5.9 kw per rack 160 kw 4 x 20 ton Precision Cooling systems Units 2 x 100 kva room-level UPS systems and power distribution Racks and Integrated Cabinets 6

Liebert CRV Row-based Cooling, 20-40kW Ideally suited and designed for cooling server rack cabinets in small and medium data centers. Features Liebert icom controls, variable speed EC fans and a digital scroll compressor, for high reliability and energy efficiency. DCF Optimized Racks 19 data center rack system from Vertiv Network Power integrates computing hardware, power management technologies and peripherals. It provides superior design flexibility, with optimized thermal and cable management features, and tool-less accessories. Liebert APM On-line UPS, 15-90kW This row-based, transformer-free, on-line UPS allows quick and easy capacity increases with FlexPower hardware assemblies - no additional floorspace required. The UPS operates with the industry s highest efficiency - up to 94% at loads of 50-100%. Liebert MB Modular Busway Provides high density power distribution to the rack while eliminating cable clutter that can reduce airflow. This modular system is easy to install, and is easily expanded with a variety components in configurations to meet unique site needs. Aisle Containment Systems Separates hot and cold air streams for better cooling operation and higher efficiency. Doors and ceilings in Modular, Vertical and Retractable systems contain data center racks and IT equipment. MPX and MPH2 Rack PDUs Adaptive and managed rack power distribution units allow remote monitoring and control at the receptacle level, as well as monitoring of environmental input options such as rack temperature and humidity. Rugged construction and industry s leading operating temperatures. SMARTAISLE Racks 16 Density 10kW per rack Total IT Load 160 kw Cooling Units 6 row-based precision cooling units Cold Aisle Containment Power 2 row-based UPS systems Modular power busway 7

VertivCo.com Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA 2016 Vertiv Co. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice. SL-11400 (R10/12)