ICTD-100CP / ICTD-101CP ICTD-102CP / ICTD-103CP

Similar documents
ADDENDUM FOR 20, 27, & 28 OPTIONS

Intermountain Electronics Electronic and Electro-Mechanical Components

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

High Voltage Power Supply (MMPS) - Troubleshooting Guide

IRG30 / IPL30 IRG60 / IPL60

Power Entry. Version 1.0 June 2, 2017

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

Document C0. Use for:

SE-701 MANUAL GROUND-FAULT MONITOR

RFD-200 TM. Test a Wide Variety of Relays in their Outdo FEATURES AT A GLANCE. Auxiliary AC/DC Power Supply. RFD-200 S2 Ampere Meters

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

PFC Mini TM Power Factor Corrected AC-DC Switchers

Model 7705 Control Module

User Guide Regenerative & Non-Regenerative Digital DC Drives 5 to 1000 HP

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

Intermountain Electronics Electronic and Electro-Mechanical Components

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

Technical Practice BP-2 POWER FAILURE TRANSFER UNIT. Issue 8, April 1988

CCPF-3500-XX OPERATION MANUAL. Lumina P/N

Energy Management System. Operation and Installation Manual

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

Safety Control Relay Product Catalog

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II

Installation instructions DC Protection and Delay unit, Version 1.2 The package should contain: A piece of normal gauge yellow wire for the AC connect

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION

Resolver to Digital Expansion Board

ENERGY / POWER METER - digital

Automation Interface Requirements for System I/O Interface of a DPC I Welding System

INSTALLATION AND OPERATING MANUAL BERTAN SERIES 602C, 603C, 605C, 606C, 612C

Time delay undervoltage module

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

PGR-2601 MANUAL DC GROUND-FAULT RELAY

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

ADDENDUM TO IB17555D INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE OF THE CUTLER-HAMMER DIGITRIP 3000 SERIES OF PROTECTIVE RELAYS

Advanced Distribution Cable Junction Box For Spectra RMS Molded-Case Circuit Breakers with Advanced Feature microentelliguard TM Trip Units

USER MANUAL CCPF-500-XX CCPF-750-XX 500 to 750 J/s Capacitor Charging Power Supply Series

Installation Instructions

Manual Control Unit GFC 32

Switching Control Sentinel (SCS) TM For all ABB independent pole operated circuit breakers

Operating Instructions. For. Level Control Module. Model SSR 1000

INSTRUCTION MANUAL. Card Revision: Software 2.1 Card Revision: Hardware B(2.0) DOCUMENT SES-KS-2422-E REV. 3

DTC P0AA6 - High Voltage Isolation Fault

Model HM-535 Power Supply Installation and Service Instructions

DELOMATIC - MULTI-FUNCTION SYSTEM PART 2 INSTALLATION INSTRUCTION

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

Specifications, Installation, and Operating Instructions

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Manual Simatek Control Unit GFC 32

ZC Series Zone Monitoring Controllers

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

Operating instructions Evaluation system for flow sensors VS / / 2013

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

FX1N JAPANESE SPECIFICATION UNITS

The accessory described in this manual is a high quality product that has been carefully designed and manufactured to guarantee optimal performance.

Quick Start Guide TS A

Voltage Dip-Proofing Inverter

MX1 Reversible AC Motor Controller. Supplementary Wiring Examples

FLEXmax 100 with ICS Plus

Overview Included in the Box: Pinout Installation Power Supply Stepping Motors DIP Switch (JP1) Location...

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

FOR SERVICE TECHNICIAN S USE ONLY

Mobrey Hydratect 2462

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Energy Harvesting Engine

Product Information. Release 3 4 SIMATIC S7-300

Installation & Operation Guide

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

T3 Interface Converters

Transient Voltage Protection for Stratix GX Devices

PLCADD1616 User Guide 3/29/10. Overview

Hypot III. Graphic Liquid Crystal Display. 10 Memories with 3 Steps per Memory. Low Limit Detection System. SmartGFI Circuit (Patent Pending)

1. Introduction ALSPA MV DELTA

Voltage Dip-Proofing Inverter

SACE Emax 2 Specification guide

Application Note. Common Bussing AC Drives. For 584SV and 620 series drives APP-AC-02

LAMBDA EMI 405 ESSEX ROAD, NEPTUNE, NJ 07753

DIN Molded Cable Assemblies

ADVANCED MICRO SYSTEMS

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 740 TRACKER/SEQUENCER DEMO BOARD

1352C-Plus 5.1 VECTOR Troubleshooting Guide

INSTRUCTION MANUAL FOR

Residual overvoltage relay

Medium Power Wireless Energy Harvesting Assembly

Start Relay Circuit - Test

FOR SERVICE TECHNICIAN S USE ONLY

FRICK QUANTUM ACUair CONTROL PANEL VERSION 2.1x

HV-CS kv Edge Mount Triaxial Jack

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

New Solutions. for AC Motor Starters

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

********SERVICE MANUAL******** MODELS:

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

Transcription:

PATENT PENDING ICTD-100CP / ICTD-101CP ICTD-102CP / ICTD-103CP Capacitor Trip Devices with Contact Protect Technology TM Operation Manual and Data sheet

2015 Intermountain Electronics, Inc. Important Notice This document contains information intended to aid in the proper installation and operation of the product described. Although this information will prove useful to the properly trained and qualified user, it is not practical to cover every possible situation, installation contingency, or other detail. It is imperative that proper engineering and techniques are adhered to in the installation, operation, and maintenance of this product. It is the responsibility of the user to ensure that any system utilizing this product is safe, and that all personnel involved with the selection, installation, maintenance, and use of this product are properly qualified. This product must not be used in situations where its ratings are exceeded. While every effort has been made to make sure the information in this document is accurate, IE cannot guarantee that there are no errors. Users of this product should verify any aspects of the product s design or performance that are critical to their application, and in particular, any aspects that may affect the safety of the overall system or installation. Product design and specifications may change without notice.

Table of Contents I: General Information.............................. 1 II: Controls & Connections........................... 2 III: Operation & Specifications......................... 3 List of Figures & Tables Figure 1: Front Panel................................... 2 Figure 2: Rear Panel................................... 2 Figure 3: ICTD-10xCP Block Diagram..................... 4 Figure 4: TRIP W/ ERROR Jumper......................... 5 Table 1: Connector Pin-Out............................. 2 Specifications........................................ 6 Models and Part Numbers.............................. 6 Mechanical Dimensions and Panel Cut-out............... 7

1 I: General Informaon The patent-pending ICTD-10xCP family of Capacitor Trip Devices (CTDs) are the most advanced products of their kind. Every model is microprocessor based, and each features revolutionary innovations, including Contact Protect Technology TM, which greatly improve performance, reliability, and safety. Key features include: Contact Protect Technology TM eliminates the common problem of arcing damage to auxiliary (AUX) switch contacts. Easy-to-read level indicator allows instant verification of the capacitor reservoir charge level. ICTD-103CP Unique DISCHARGE button allows the reservoir to be quickly discharged for safety--no need to arc the trip circuit to do maintenance. Large 5000uF (69 joules) capacitor bank. Open Coil Circuit indicator verifies when a trip circuit is in place. Specially designed sensing circuitry detects both traditional trip coils and modern trip circuits. Open Circuit Test button (ICTD-101CP, -103CP) allows open coil circuit to be tested. UVR interlock function (ICTD-102CP, -103CP) with test button improves safety by preventing the circuit breaker from being closed until the capacitor reservoir is charged. Microprocessor and exclusive watchdog circuitry constantly monitor operation to ensure reliability and safety. Expansion module port allows the addition of IE expansion modules for extra connectivity options, such as external monitoring, control, and diagnostics. Fully enclosed chassis to improve reliability and product life-time. Contact Protect Technology TM (Patent Pending) In a typical circuit breaker installation, the breaker is tripped by energizing its trip circuit using energy stored in a CTD. As soon as the breaker is tripped, a breaker auxiliary contact is used to disconnect the CTD to prevent damage caused by continuously powering the breaker s trip circuit. Unfortunately, auxiliary contacts in most breakers are only AC rated, and traditional CTDs only provide DC current. As a result, auxiliary contacts are commonly damaged, and this damage often extends to the breaker s trip circuit. Contact Protect Technology TM eliminates this problem by converting the DC energy stored in the CTD to an alternating current before delivering it to the trip circuit.

2 II: Controls & Connecons Specificaons: Figure 1: Front Panel Reservoir Level Indicator: Indicates the charge level of the energy storage capacitor reservoir: Fully charged Adequate charge to trip breaker Low charge - may not be able to trip breaker Power Indicator: Lit when control power is on Discharge button: Hold to quickly discharge the capacitor reservoir for safety when doing maintenance Always remove control power and discharge the reservoir before performing system maintenance. Error Indicator: Lit in the event of that an error is detected UVR Test Button (if equipped): Allows UVR function to be tested by deactivating the UVR output, causing the circuit breaker to trip UVR Indicator (if equipped): Lit when the capacitor reservoir has sufficient charge to cause a trip if needed, and the Under -Voltage Relay (UVR) interlock output is active Open Coil Circuit Test Button (if equipped): Allows the trip circuit to be tested by forcing the circuit breaker to trip Open Coil Circuit Indicator: Lit when a trip circuit is detected Figure 2: Rear Panel I/O Connector: Includes necessary connections for normal operation: Table 1: I/O Connector Pin-out Pin Purpose 1 120V (Neutral) 2 120V (Line) 3 Trip Circuit Connec&on 4 Unused 5 Under-Voltage Relay (UVR) Interlock Output 6 To trip circuit and breaker AUX switch 7 To trip contacts and breaker AUX switch 8 To trip contacts 9 Chassis ground Optional IE Expansion Modules Expansion Port: Installation location for optional IE expansion modules.

3 III: Operaon & Specificaons General Description The purpose of a Capacitor Trip Device (CTD) is to store energy in a capacitor bank, which acts as a reservoir, to be used in case there is a temporary loss of 120V AC control voltage. This energy may be used to trip a circuit breaker if the need arises, even when control voltage has failed. Unique innovations Patent pending Contact Protect Technology TM protects AUX switches or other contacts in circuit breaker trip circuits. These contacts are often AC rated, but most CTDs can only provide DC current to the trip circuit. This DC current can damage the AC contacts, which, in turn, may cause other damage. Contact Protect Technology TM eliminates this issue by converting reservoir current to an alternating signal compatible with AC rated contacts. A unique 3 color bar graph constantly indicates the level of the reservoir. A DISCHARGE button allows the reservoir to be quickly discharged for safe maintenance. On-board diagnostics and watch-dog circuitry constantly monitor all key functions, and redundant components in critical circuits provide unmatched circuit reliability. Unique open circuit sensing circuitry works equally well for traditional shunt coils or modern high-z circuits, without having to set a jumper or make a circuit change. When equipped, UVR and Open Coil Circuit indicators with corresponding test buttons allow verification that UVR interlock and opening coil circuits are connected properly and functioning. Like IE s other ICTD family capacitor trip devices, the ICTD-10xCP models include an IE expansion module port. Optional IE expansion modules, such as 1100-7100 or 1100-7110, may be installed in this port to provide additional features (refer to the manuals and spec sheets for each expansion module for details). For example installing an expansion module can provide additional functions such as: Remote status monitoring of key parameters (e.g. reservoir charge level, etc.) Remote control of key functions (e.g. open coil circuit or UVR test) External diagnostic monitoring to verify unit is working properly Theory of operation Figure 3 shows the block diagram for the ICTD-10xCP. When there is control power, the capacitor bank charges quickly through the rectifier to about 170VDC. The capacitor bank then stores this energy for use if control power fails. The 170V supply circuit selects between the rectified control voltage (when the capacitor bank is not charged) and the capacitor bank (when there is no control voltage) to provide a reliable 170V supply. The 170V supply powers the external trip circuitry, which trips the breaker if trip contacts are closed. Current from the 170V supply that is drawn through the external trip circuity is converted to alternating current by a DC-AC circuit, which chops the signal, based on an oscillator in the microprocessor. This alternating current will not damage AC-rated circuit breaker AUX contacts (or any other similar contacts) in the trip circuitry. The capacitor bank can be quickly discharged after control voltage is removed, by holding down the DISCHARGE button. This removes the 170V from external circuits to allow for safe maintenance.

4 Figure 3: ICTD-10xCP Block Diagram An open circuit detector circuit senses the level of a small test current that is fed through the circuit breaker s opening (trip) coil or circuit. The microprocessor measures this current to determine if an open coil or circuit is present. The breaker s opening coil or circuit can be tested by pressing the OPEN COIL CKT TEST button, which will force the breaker to trip if it is wired properly. An Under-Voltage Relay (UVR) function is operated by the microprocessor, which energizes the UVR relay when the capacitor bank is fully charged. This relay may be connected to a breaker s UVR to prevent the breaker from being closed if there is insufficient energy in the reservoir to perform a trip. The UVR function can be tested by pressing the UVR TEST button, which will open the UVR relay, causing the breaker to trip. The microprocessor directly operates most of the indicators (level indicator, OPEN COIL CKT, UVR) to make sure they are appropriately lit or unlit. The ICTD-10xCP constantly monitors its own operation, using error detecting software and circuitry to make sure everything is working properly:

5 A power monitoring circuit monitors the key supply voltages, and provides supply status to the microprocessor, which constantly monitors for any malfunction. The microprocessor also monitors other key aspects of the operation to make sure no malfunctions occur. The microprocessor itself is also monitored by a watchdog system. This system consists of error detecting software and an independent watchdog circuit. If the microprocessor begins to operate incorrectly, the watchdog system will detect the problem. If any problem is noted by the microprocessor or watchdog circuit, an error signal is activated, which causes the ERROR indicator to be lit. The error signal is also available on the expansion port for external diagnostic monitoring (an expansion port must be installed). Additionally, depending on the position of the user-settable TRIP W/ERROR jumper on the main PCB, a detected error may or may not cause the circuit breaker to trip. (The factory default is to not force a trip when an error is detected.) The jumper is located on the edge of the front PCB (See Figure 4), and can be set either through the access panel on the right side of the ICTD-10xCP (using needle-nose pliers), or by simply opening the chassis. Because of the ICTD-10xCP s fault-tolerant design, the unit may continue to work even if an error is detected. However, if the error indicator remains on after a power-down cycle, then something is not working properly, and the unit should be replaced or repaired. Because of the advanced nature of the design, we strongly recommend that repairs only be done at an IE repair facility. Figure 4: Access Port and TRIP W/ ERROR Jumper Removable Access Panel Breaker will not trip if error is detected (Factory default) Breaker will trip if error is detected Note: Make sure power is off, and the capacitor reservoir is fully discharged before opening chassis or opening the access panel to access the jumper.

6 Specifications Input voltage (Control Voltage): Power Draw, continuous: Momentary (turn on, caps uncharged): Capacitor Charge Time: Storage Capacity: Typical capacitor storage time: Output voltage (fully charged): Required Trip Contact rating: UVR Relay Contact rating: Error Jumper settings: Position 1 (Labeled TRIP W/ ERROR ) Position 2 (Factory Default) Weight: 120 VAC 100mA at 120VAC (caps fully charged, normal operation) 7A peak at 120VAC (during capacitor charge time) Less than 1 Second 5000uF/66 Joules 40 Seconds (varies for different shunt coils/circuits) 160-170V (Chopped DC) 10A/240VAC (Resistive) 8A/250VAC (Resistive) Breaker will trip if an error is detected Breaker will not trip if an error is detected 3 lbs / 1.3 kg Models and Part Numbers Model: Part number Description ICTD-100CP 1100-7004 Capacitor Trip Device featuring Contact Protect Technology TM, cap bank level indicator, OPEN COIL CKT READY indicator ICTD-101CP 1100-7005 Same as ICTD-100CP, plus OPEN COIL CKT TEST button ICTD-102CP 1100-7006 Same as ICTD-100CP, plus UVR Indicator and UVR TEST button ICTD-103CP 1100-7007 Same as ICTD-100CP, plus UVR Indicator, UVR TEST button, and OPEN COIL CKT TEST button. ICTD-100CP ICTD-101CP ICTD-102CP ICTD-103CP

Mechanical Dimensions Panel Cutout 2000-1228-A