HP EVA4400 M6412 drive enclosure

Similar documents
HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

HP P6300/P6500 EVA Fibre Channel Controller Replacement Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

System Storage EXP3000 Rack Installation Instructions

Ion Memory Upgrade. Visit the AMI Entertainment Web site PM

Rack Installation Instructions

Field Service Guide Supplement for the NS 7000/030

Rack Installation Instructions

Upgrading and Servicing Guide

IBM. Rack Installation Instructions

Upgrading and Servicing Guide

Installing the Cisco SFS 3504 Server Switch

To connect the AC adapter:

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

Customer Upgrade Procedure

HP ProLiant DL380 Generation 3 Packaged Cluster Setup and Installation Guide. January 2003 (Second Edition) Part Number

Customer Replacement Procedure

Replacement Keyswitch Assembly

Oracle <Insert Picture Here>

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Upgrading and Servicing Guide

Gateway Profile 4 service guide

HP ProLiant DL380 Generation 3 Server Maintenance and Service Guide. May 2003 (Third Edition) Part Number

Replacement Instructions. Backplane PCA for the HP Router 650

Replacing the Power Supply

Upgrading and Servicing Guide

Instructions for SVC-KIT-0020

Replacing the Battery HP t5730 and t5735 Thin Clients

Dell Inspiron N5110 Service Manual

Sun StorageTek SL48 Tape Library Getting started

Adding or Replacing a PCI Card

SGI InfiniteStorage 120

2U STORAGE ENCLOSURE QUICK INSTALL GUIDE FS4100, FS4500, SC4100, AND FC4100

hp StorageWorks MSL5000 and MSL6000 series pass-through mechanism

Installing the Server into a Rack

Replacement Instructions

Replacing a 3.5-inch disk drive

Upgrading and Servicing Guide

SCSI Cable Installation Instructions

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Power Supply and Fan Module Installation

Upgrading and Servicing Guide

HP ProLiant DL165 G7 Server

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.

EXN4000 Storage Expansion Unit Installation and Setup Instructions

SCv3000 and SCv3020 Storage System. Owner s Manual

Managing Individual Components

IBM Systems. Quick start guide for IBM System p5 505 ( )

SCv360 Expansion Enclosure

MODULUS 21 Power Distribution Unit (PDU) Replacement. Overview A. Introduction

Dell SC5020 and SC5020F Storage System Owner s Manual

N3240 Installation and Setup Instructions

Customer Replacement Procedure

SuperLoader 3 Quick Start Guide

System Storage DS3950 Quick Start Guide

Customer Replacement Procedure

Liebert XDA Air Flow Enhancer. User Manual

Removing and Replacing Parts

120Ra-1 Pentium III Processor Installation Insert

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Installation and Getting Started Guide. HP ProCurve 600/610 External Power Supplies. PoE. Power over Ethernet Devices

HP VISUALIZE B2000 UNIX Workstations

Replacing an Advanced Power and Cooling (APC) Unit

Customer Replacement Procedure

EMC VNXe. Adding input/output modules to a disk processor enclosure REV 03. July, 2015

Customer Upgrade Procedure

Conversion Instructions for SSG 300M-series Security Devices and J-series Services Routers

9109 FXS Analog Voice Application Module (APM) Installation Instructions. Product Documentation on the World Wide Web

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.

EXN3000 Storage Expansion Unit Installation and Setup Instructions

Dell XPS L702X Service Manual

TRC-190 User s Manual

Rack Installation Instructions

Dell XPS 14z Owner s Manual

Section. Service & Maintenance. - Core & Hard Disk Drive (HDD) - Amplifier - Monitor - UPS - Dollar Bill Acceptor - Fan Filter G - 1

Sun StorageTek SL24 Tape Autoloader Getting started

Installing IDS-4235 and IDS-4250

TRC-190 User s Manual

HPE OfficeConnect 1420 Switch Series

Maintaining E-Series Routers

Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter. HP Part No. A Edition E1197 Printed in U.S.A.

Maintaining the Avaya S8800 Server for Avaya Aura SIP Enablement Services

hp uninterruptible power system r12000 xr models installation instructions

E2460GS Oscilloscope Upgrade Kit

H3C S12500 Routing Switch Series

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

13 MMC for PC Option Modules

1. Move the cardboard carton close to the installation site, making sure you have adequate space to remove all the contents of the box.

FreeNAS Mini and Mini XL Network Upgrade Kit

HP ProLiant SL160z G6 Server

1 Getting Started Installing & Configuring

Nvidia Quadro FX 5600 graphics card and auxiliary power adapter cable installation

INSTALLATION INSTRUCTIONS

Removal and Installation8

Inspiron 22. Service Manual Series. Regulatory Model: W17B Regulatory Type: W17B001

Dell SC460 Expansion Enclosure Getting Started Guide

ProLiant ML350 Tower-to-Rack Conversion Guide. First Edition (September 2000) Part Number Compaq Computer Corporation

Installing the Cisco MDS 9020 Fabric Switch

Transcription:

HP EVA4400 M6412 drive enclosure installation instructions HP Part Number: 5697-0975 Published: June 2011 Edition: Second

Copyright 2008, 2011 Hewlett-Packard Development Company, L.P.

About this document This document describes how to install an M6412 drive enclosure into a cabinet as part of an EVA4400 storage array. The drive enclosure installation may be performed while the array is in operation. NOTE: You can only add one disk enclosure online at a time. Before you begin Read the following warnings and cautions before installing the drive enclosure. WARNING! Make sure that the rack is sufficiently stable. If provided, lower the cabinet leveler feet and make sure any required stabilizers are installed. If provided, extend the rack anti-tip device. Failure to extend the anti-tip device could result in personal injury or damage if the cabinet tips over. CAUTION: Kit contents Make sure that the cabinet and all equipment mounted in the cabinet have a reliable ground connection. Verify that the total current of the cabinet components does not exceed the current rating of the power distribution unit or the power distribution modules. Parts can be damaged by electrostatic discharge. User proper anti-static protection. For additional information, see the documentation that shipped with your system. Check the kit contents to make sure you have the items listed in Figure 1 (page 3). Figure 1 Kit contents 1 Drive enclosure 5 Rails with 03 brackets 2 Eight disk drive blanks (may come preinstalled in enclosure) 6 Two Fibre Channel copper cables 3 04 brackets (not used) 7 Two enclosure power cords 4 Pins for round-hole cabinet conversion Attaching the rails The cabinet rail kit supplied with the drive enclosure comes configured for square-hole cabinets. If you need to convert the rails for a round-hole cabinet, perform the following steps: About this document 3

IMPORTANT: Do not remove the pins from the ends of the cabinet rails unless you are converting the rails for use in round-hole cabinets. These load-bearing pins are designed to fit through the holes without being removed. 1. Locate the bag of eight round-hole pins that is included in the cabinet rail kit. 2. Use a No. 2 Phillips screwdriver to remove the standard pins from the front and back of the left and right rails (four on each rail). See Figure 2 (page 4). Figure 2 Square hole to round hole cabinet conversion 3. Attach the round-hole pins into the eight holes on the rails where the standard pins were removed. To attach the rails to the cabinet: NOTE: The designation of left and right rail is made when looking at the front of the rack. The rails are marked by an R (right) and L (left) stamped on the metal. 1. Insert the rear end of the right rail into the inside back of the cabinet until the pins partially extend through the holes in the cabinet upright. 2. Squeeze the scissors latch together to insert the rail and pins though the cabinet upright holes until the latch engages. See Figure 3 (page 4). Figure 3 Attaching the right, rear rail 3. Extend the front end of the right cabinet rail toward the inside front of the cabinet. 4. Pull the locking latch to release the scissors latch (1, Figure 4 (page 5)) and squeeze the scissors latch together to insert the rail and pins through the cabinet upright holes (2) until the latch engages (3). 4 Attaching the rails

Figure 4 Installing front, right rail 5. Loosen the locking nut on the shipping retaining bracket (1, Figure 5 (page 5)) and slide the bracket to the farthest position on the rear of the rail (2). This moves the bracket out of the way to allow you to install the enclosure in the rails. Figure 5 Move back retaining bracket 6. After attaching the rail, grab and move the rail gently to be sure it is firmly engaged in the cabinet and that all latches are engaged in the cabinet holes. 7. Repeat the above steps for the left rail. Attaching the rails 5

Installing the drive enclosure 1. Remove the bezel covers from each side of the enclosure (see Figure 6 (page 6)). CAUTION: Be careful when removing the bezel covers so as to not break the locking tabs that secure the covers to the enclosure. Figure 6 Bezel cover removal 2. Align the enclosure with the rails and slide it into the cabinet. Figure 7 Slide drive enclosure onto rails 3. Continue sliding the enclosure into the cabinet until the front edge is flush with the front of the rack (1, Figure 8 (page 7)). Tighten the enclosure thumbscrews into the cabinet (2), taking care to not strip the Phillips-head thumbscrews. 6 Installing the drive enclosure

Figure 8 Tighten drive enclosure to cabinet 4. Reattach the front bezel covers. 5. At the rear of the cabinet, slide the shipping retaining bracket forward on both rails until the tab engages the slot in the drive enclosure. Tighten the bracket thumbscrews. 6. Populate the enclosure with available disk drives (not included with this kit), starting with the lowest number in Figure 9 (page 7), and continuing in order until you have inserted the desired number. If installing multiple drive enclosures, balance the quantity and sizes of disk drives between the enclosures as evenly as possible. Figure 9 Disk drive numbering Figure 10 Inserting a disk drive Installing the drive enclosure 7

7. Insert drive blank into any slots without a disk drive. Push the drive blank until you detect a click. Figure 11 Inserting a drive blank Cabling the enclosure Two methods are described for cabling a new drive enclosure. The online method allows a drive enclosure to be added to a powered operational array. The offline method describes cabling an array that has been powered down. The offline method is preferred if downtime is available. NOTE: One controller enclosure (with two controllers) can support up to eight drive enclosures. The power cords are supplied in two different colors should you decide to use the colors to denote sides of the cabinet. For example, you can locate all gray power cords on the left side of the cabinet, and all black power cords on the right side. Cabling the enclosure while offline 1. Power down the array. Figure 12 (page 8) shows the cabling for an array with one controller enclosure and three drive enclosures. As a general cabling guideline, the P1 port on the I/O module receives input from another I/O module or a controller, and the P2 port is used for output to another I/O module or controller. In the steps performed below, one side of the drive enclosure (I/O module A on the left side) is cabled, and then I/O module B is cabled. However, either I/O module can be cabled first when power is not applied to the array. Figure 12 Cabling for preexisting array 8 Cabling the enclosure

2. Figure 13 (page 9) shows the cabling when another drive enclosure is added to the bottom of the array. The dashed lines leading to the controller enclosure show cables that are moved, and dashed lines between the drive enclosures show cables that are added. Unplug the Fibre Channel cable from I/O module A port P2 of the drive enclosure nearest the newly installed drive enclosure, and plug it into the P2 port of I/O module A of the newly installed drive enclosure (1, Figure 13 (page 9)). This should be a long cable with the far end connecting to controller 2 port DP1 A in a configuration with all the drive enclosures installed above or below the controller enclosure. If drive shelves are installed above and below the controller enclosure, see Figure 14 (page 11). Figure 13 Addition of drive enclosure to array 1 2 3 4 Connects installed I/O module A, port 2 to controller 2, port DP1 A Connects installed I/O module A, port 1 to existing I/O module A, port 2 Connects installed I/O module B, port 2 to controller 1, port DP1 B Connects installed I/O module B, port 1 to existing I/O module B, port 2 3. Using a Fibre Channel copper cable provided in your kit, plug one end into the P2 port of I/O module A that was unplugged in the previous step, and plug the other end into port P1 of I/O module A in the newly installed drive enclosure (2, Figure 13 (page 9)). 4. Perform steps 2 and 3 on I/O module B of the newly installed drive enclosure. The results are the Fibre Channel cable on I/O Module B port 2 of the nearest drive enclosure is moved to I/O module B port 2 of the newly installed drive enclosure (3, Figure 13 (page 9)). In addition, a new Fibre Channel copper cable is installed between I/O Module B port P2 of the preexisting drive enclosure and I/O module B port 1 of the newly installed drive enclosure (4). 5. Using a power cord provided in your kit, plug one end into a drive enclosure power supply and the other end into a cabinet power distribution module. 6. With the remaining power cord, connect the other power supply to a cabinet power distribution module. 7. Press the Power On/Standby button on the power UID bezel (located at the rear of the drive enclosure) and hold it down long enough to power up the installed enclosure. Cabling the enclosure 9

8. Power on any other drive enclosures attached to the array and visually check that the enclosures power on without errors. Wait at least one minute after all the enclosures are powered on for the drives to spin up and stabilize. 9. Power on the controller enclosure by pressing the power button on the power UID bezel until the enclosure responds (it may take up to 10 seconds for the controller enclosure to power on). Wait five minutes for the array to stabilize. 10. Verify that I/O modules A and B on the added enclosure have been assigned an index number of the next higher enclosure number. For example, if the previous highest index number was 3, then the installed enclosure should display 4. 11. In HP P6000 Command View, verify that the newly installed drive enclosure appears in the array hardware pane, and that the I/O modules show a good operational status. Cabling the enclosure while online NOTE: You can only add one disk enclosure online at a time. 1. Using a power cord provided in your kit, plug one end into the drive enclosure power supply and the other end into a cabinet power distribution module. You will briefly hear a rush of air as power is applied, and the LEDs on the power UID flash. The power UID standby switch LED remains amber. 2. With the remaining power cord, connect the other power supply to a cabinet power distribution module. The power UID power switch LED turns green. The I/O module index number will likely display 00, but if not, ignore the index number at this time. 3. Figure 12 (page 8) shows the cabling for an array with one controller enclosure and three drive enclosures. As a general cabling guideline, the P1 port on the I/O module receives input from another I/O module or a controller, and the P2 port is used for output to another I/O module or controller. In the steps performed below, one side of the drive enclosure (ports P1 and P2 of I/O module A on the left side) is cabled, and then I/O module B is cabled. Either I/O module can be cabled first as long as the other I/O module ports are not unplugged until cabling is complete on the first I/O module. This allows the controller to redundantly manage the storage while the cables are briefly pulled and reconnected on one side. 4. Figure 13 (page 9) shows the cabling when another drive enclosure is added to the bottom of the array. The dashed lines leading to the controller enclosure show cables that are moved, and dashed lines between the drive enclosures show cables that are added. Unplug the Fibre Channel cable from I/O module A port P2 of the drive enclosure nearest the newly installed drive enclosure, and plug it into the P2 port of I/O module A of the newly installed drive enclosure (1, Figure 13 (page 9)). This should be a long cable with the far end connecting to controller 2 port DP1 A in a configuration with all the drive enclosures installed above or below the controller enclosure. If drive shelves are installed above and below the controller enclosure, see Figure 14 (page 11). 5. Using a Fibre Channel copper cable provided in your kit, plug one end into the P2 port of I/O module A that was unplugged in the previous step, and plug the other end into port P1 of I/O module A in the newly installed drive enclosure (2, Figure 13 (page 9)). Wait for the port to become visible with HP P6000 Command View. NOTE: With only one I/O module from the newly added enclosure cabled to the array, there will be HP P6000 Command View warnings that indicate disk drives in the system are only connected on one of the redundant Fibre Channel loops. This is to be expected, and the warnings should clear as soon as the other I/O module is connected. 6. Perform steps 4 and 5 on I/O module B of the newly installed drive enclosure. The results are the Fibre Channel cable on I/O Module B port 2 of the nearest drive enclosure is moved to I/O 10 Cabling the enclosure

module B port 2 of the newly installed drive enclosure (3, Figure 13 (page 9)). In addition, a new Fibre Channel copper cable is installed between I/O Module B port P2 of the preexisting drive enclosure and I/O module B port 1 of the newly installed drive enclosure (4). 7. Verify that I/O modules A and B on the added enclosure have been assigned an index number of the next higher enclosure number. For example, if the previous highest index number was 3, then the installed enclosure should display 4. 8. In HP P6000 Command View, verify that the newly installed drive enclosure appears in the array hardware pane, and that the I/O modules show a good operational status. Alternate enclosure cabling Drive enclosures may have to be installed where room is available in a cabinet. Figure 12 (page 8) and Figure 13 (page 9) show drive enclosures mounted in a cabinet on just one side of the controller enclosure. When drive enclosures are mounted on both sides of the controller enclosure, the cabling is logically the same, in that all the drive enclosures are connected serially. In this case, the long Fibre Channel cable goes from the I/O module P2 port of the last drive enclosure on one side of the controller enclosure to the farthest drive enclosure on the other side of the controller enclosure. The last drive enclosure in the series (near the controller enclosure) completes the loop back to the controller. Figure 14 (page 11) shows this cabling configuration with drive enclosures above and below the controller enclosure in an array. Installing a drive enclosure above or below this configuration would keep the same pattern of cabling between the drive and controller enclosures. Figure 14 Array cabling for drive enclosures on both sides of the controller enclosure Cabling the enclosure 11