Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Similar documents
Precision Cooling Mission Critical Air Handling Units

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

YORK SOLUTION AIR HANDLING UNITS

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES

Filter Fan Unit LIGHT

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC

DCC Commercial. Submittal Data Form Tons Packaged Air Conditioners

Self-Contained Air Conditioning Systems

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

1.5 to 5 Tons INDOOR COILS CX35. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

DCG Commercial. Submittal Data Form

STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling

1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES

J&M Fluidics, Inc. Company Product Overview

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling

Thermal management. Thermal management

Brasch Washdown Unit Heaters

Rear Door Heat Exchanger

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

Specification and Design Catalog. Waterside Economizer

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full perimeter rail Sloped drain pan

HIGH EFFICIENCY Central Chiller

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY.

PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

InPac 600 Series Fully configurable severe duty and explosion proof HVAC and building pressurization systems 2 5 ton ::

CTC Low Temperature Process Chillers

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

ENCLOSURE HEAT DISSIPATION

Motors & Controls Product Guide

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

DTH Series. Submittal Data Form. 3-5 Tons Heat Pumps 15 SEER Up to 13.0 EER / 8.2 HSPF

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

ASPT Series. Multi-Position, Internal TXV. Air Handler 1½ to 5 Tons

Ecotel Free Cool 5-15kW

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,

GP SERIES Packaged Chillers

Creating an Energy-Efficient, Automated Monitoring System for Temperature and Humidity at a World-Class Data Center

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

OPEN FACE Industrial East Grand Ave., Pomona, CA Fax:

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

Your Clean Air Source!

Close-coupled cooling

CyrusOne Case Study About CyrusOne

T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management

Rack & Enclosure Systems

PREFABRICATED SUBSTATIONS AND E-HOUSES. tgood.com. Energy, Fast!

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

aentron Energy System 1 to 900 Vdc

COOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments

CPH Series. Submittal Data Form. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. with R-410A

Liebert DM. High Performance, Sensible Cooling for Small Computer Rooms and Network Closets

Rittal Cooling Solutions A. Tropp

REPORT. Energy Efficiency of the San Diego Supercomputer Center and Distributed Data Centers at UCSD. Prepared for:

AIR ZONE INTERNATIONAL 5220 TED ST. HOUSTON, TEXAS 77040

Data Center Optimized Controls

UW Purchase Specification Section Central Cooling Water Meter Page 1 of 6

Precision Cooling. Precision Cooling Advantages

Reducing Data Center Cooling Costs through Airflow Containment

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

HP Modular Cooling System: water cooling technology for high-density server installations

Magnitude magnetic bearing centrifugal chillers

Retro-Commissioning Report

Liebert. PDX from 15 to 165 kw. Direct Expansion Solution for Small and Medium Data Centers

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired

innovations in ENVIRONMENTAL CONTROL THE SOLUTIONS OF CHOICE FOR ALL THE REASONS THAT MATTER

Building Energy Management Training Systems

Planning for Liquid Cooling Patrick McGinn Product Manager, Rack DCLC

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

Uniflair Access Floor for data centers

Installation Service. 1.0 Executive Summary. Factory Trained Technician Train Customer Support Staff On Basic Operation Of The Equipment

Product Data HC2, HC3 HOT WATER COIL - CASED MULTIPOISE

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

RUGGED MILITARY GRADE

ACFD12-T ACFD12-B. Technical Data

Liebert DCW CATALOGUE

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone

Rheem Prestige Series Two-Stage Air Conditioners equipped with the Comfort Control 2. System. RASL- JEC Series

Rheem Prestige Series Two-Stage Air Conditioners equipped with the Comfort Control System

Ecoflair Air Economizers

Wall-Mounted Air Conditioners with PLC Technology. Let Logic Control The Flow

Rittal LCP T3+ High-availability IT cooling with no compromise

Magnitude magnetic bearing centrifugal chillers

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

Transcription:

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

DATA CENTER COOLING EXPERTISE Data Center managers have unique needs. Nortek Air Solutions listens to your needs and responds with innovative, engineered solutions to meet the specific requirements of your data center applications. Our people have extraordinary experience in the exacting demands of mission critical facilities to provide you with the best and most economical solution for the entire life cycle of your data center. Your Benefits Flexibility to design a system with the lowest possible footprint to maximize available space for computing and/or data storage equipment. Close match of operating capacity requirements to avoid the inefficiencies and added electrical demands of over-sized equipment, while often allowing for expansion within the existing footprint. N+1 redundancy at the lowest possible connected horsepower and footprint. Robust equipment with low maintenance requirements and easy access to components to avoid downtime. Control Features Fully programmable BMS interface Monitor and Alarm Points Temperature Relative humidity Airflow Filter condition Drain pan water detection Fire shutdown VFD relay alarms Smoke detection For more information about Nortek Air Solutions data center solutions, contact us at nortekairinfo@nortek.com.

COMPUTER ROOM AIR HANDLER High Efficiency Cooling for High Density Loads The Nortek Air Solutions Computer Room Air Handler (CRAH) is designed for high density load areas where a large cooling duty is required from a compact footprint, and provides the reliability and redundancy required for the critical application of data center cooling. Custom size units are available from 85 525 kw providing the flexibility to reduce the number of units, electrical and piping requirements as well as indoor footprint devoted to computer room cooling. All configurations have energy reduction features as well as heating or humidification options. The full product portfolio has been designed with a rigid welded tube frame and panel construction to maximize the unit s strength and accessibility. Where side restrictions dictate, all maintenance and service can be performed through the front of the unit. The units are designed with patented FANWALL TECHNOLOGY, an innovative solution provided by Nortek Air Solutions. It delivers an optimal, efficient airflow supply with built-in system redundancy; a required capability that is crucial to the performance of data center applications. Modular component assemblies are designed for easy and quick component maintenance and replacement. DDC Controller Unit Features / Controller The CRAH is fitted with a custom programmable industrial PLC controller complete with display/user interface. The controller monitors the temperature and relative humidity and activates cooling to provide precise and efficient cooling of the supply air. Additionally, the controller monitors the in-built safety devices of the unit, which constantly monitor the healthy state of key components. Units can be monitored locally or remotely, and if required, an enhanced web-enabled controller can be supplied, providing password-restricted access from a suitable internet access point. External Panel Mount HMI

INDUSTRIAL-GRADE INDUSTRY-LEADING CHILLED WATER COIL WITH ENHANCED FIN DESIGN FAN SECTION (BACKWARD INCLINED AIR FOIL) WITH NON-OBTRUSIVE AIRFLOW MEASURING DEVICE CONTROL VALVES AND PIPING INTERNALLY MOUNTED ELECTRICAL CONTROL PANEL

CRAH COMPONENTS Cabinet The CRAH unit is constructed of double-wall galvanized sheet steel panels, with fully encapsulated 1-inch thick insulation. The CRAH cabinet is constructed using a welded structural steel tube frame and panel design. All service and maintenance items are designed to be performed from the front of the unit. The front access doors are sealed with quarter turn compression latches and adjustable hinges to seal the doors against a continuous closed cell gasket. All external frames and panels shall be coated with a Dry Powder-Baked Polyester coating similar to Tiger #7035, Drylac Series 49 which is both lead- and cadmium-free. FANWALL System Direct driven, Class 3, backward inclined centrifugal fans with air foil blades mounted in the CRAH fan base section are constructed of steel frame and panel, designed to be situated under the raised access floor are blow directly into DC space. The fans are arranged to discharge horizontally to maximize mechanical and static efficiency. The fans are rated by AMCA and balanced to exacting industry standards for specific use in our FANWALL TECHNOLOGY application. Each fan and inlet cone are fitted with a nonobtrusive airflow measuring device and optionally coupled with a transmitter to send real time volume signal to the DDC for control and transmittal of data to the BMS. The signal results in a digital readout in CFM on the touch screen HMI. Standard motors are AC type, in standard NEMA frame sizes, and TEAO design EC motors are available. Cooling Coils Downflow units use dual cooling coils arranged in an A formation. Upflow units use a single coil in a slab configuration. The casing is constructed of minimum 16 gauge galvanized steel. Fins are aluminum plate ripple type. Tubes are copper and are mechanically bonded to aluminum fins. Drain pans are 304 stainless steel with solid welded seams. All coils are rated in accordance with the Air-Conditioning, Heating and Refrigeration Institute (AHRI) Standard 410. Control Valve and Control Panel Control valves are two or three way, cast iron or brass depending on size and application. Actuators are proportional type with an operating voltage of 24v. Each unit ships complete with an independent or integral control panel. The control panel houses a main input fused disconnect with individual fused disconnect, DDC controller or programmable logic controller (PLC) and optional human mechanical interface device (HMI). The controller and HMI are factory mounted and installed for user connections and setup. It has options available for BMS interface via Modbus, LonWorks and BACnet. It can monitor all status points in the system necessary for maintaining room conditions, raised floor differential pressure or duct static pressure; and airflow with optional inputs available for customer connections and monitoring.

DOWNFLOW AND UPFLOW MODELS Downflow Cooling Units Filter Section Coil Section Fan Section Filter Section PerfectPleat 2 and 4 optional prefilters offer the efficiency and low initial resistance that you expect and require. MERV 8 & MERV 13 filters are available. Coil Section Custom heating and cooling water coils are designed and constructed for maximum efficiency in demanding applications. We offer a full range of sizes to meet specific commercial and industrial uses where high performance is necessary. Fan Section FANWALL TECHNOLOGY Designed specifically for to achieve 7% to 9% higher efficiency than other fans in their size range. AMCA certified performance. Filter Section Coil Section Permanent Magnet Motor The FANWALL Permanent Magnet (PM) motor is a brushless permanent magnet motor which has proven to be 7% to 15% more efficient when compared to NEMA Premium efficiency induction motors. Fan Section Upflow Cooling Units Fan Section Filter Section Coil Section

Specifications and illustrations subject to change without notice and without incurring obligation. FANWALL TECHNOLOGY and FANWALL are registered trademarks of Nortek Air Solutions, LLC. All other trademarks are the property of their respective organizations. www.nortekair.com nortekairinfo@nortek.com Nortek Air Solutions, LLC 2018. All Rights Reserved. 241F-0918