Intel SRCS28X RAID Controller 814G Firmware Upgrade for Intel Storage System SSR316MJ+

Similar documents
Intel Server Board S2400SC

Intel Server Board S2600CW2S

Intel Server Board S1200BTS

Intel Server Board S5520HC

Upgrading Intel Server Board Set SE8500HW4 to Support Intel Xeon Processors 7000 Sequence

GUID Partition Table (GPT)

Intel Entry Storage System SS4000-E

Intel Entry Storage System SS4000-E

Intel Server Board S2600STB

Intel Cache Acceleration Software for Windows* Workstation

Intel 945(GM/GME)/915(GM/GME)/ 855(GM/GME)/852(GM/GME) Chipsets VGA Port Always Enabled Hardware Workaround

Intel Server Board S1200V3RPO Intel Server System R1208RPOSHORSPP

Intel Server Board S1200V3RPO Intel Server System R1208RPOSHORSPP

Intel Desktop Board DQ35MP. MLP Report. Motherboard Logo Program (MLP) 5/7/2008

Intel Platform Administration Technology Quick Start Guide

Intel Desktop Board DZ68DB

Intel On-site Repair for Servers

Intel Server Board S1200KP

Windows* 2003 Cluster Implementation Guide for the Intel RAID controller SRCU42X

Intel Desktop Board DH61HO. MLP Report. Motherboard Logo Program (MLP) 09/20/2012

Intel Server Board S1400FP

Intel Server S3210SHLC

Intel Cache Acceleration Software - Workstation

Server Test Submission (STS) Report. Server WHQL Testing Services Enterprise Platforms and Services Division

Intel Server Board S1200BTL

Intel Server Board S2600CO Intel Server Board S2600COE

Intel Server S3200SHV

Intel Server Board S2400EP Intel Server System R1000EP

Intel Storage System SSR316MJ2

Intel RAID Smart Battery AXXRSBBU6

Intel Server Board S2600WP Intel Server System H2600WP

Intel Server Board S2600IP

Intel Atom Processor E3800 Product Family Development Kit Based on Intel Intelligent System Extended (ISX) Form Factor Reference Design

Intel Server Board S1200KP

Intel Server Board S2600CP Intel Server System P4000CP

Intel G31/P31 Express Chipset

Intel 848P Chipset. Specification Update. Intel 82848P Memory Controller Hub (MCH) August 2003

Intel Server Board S1200BTS

Innovating and Integrating for Communications and Storage

LED Manager for Intel NUC

How to Create a.cibd File from Mentor Xpedition for HLDRC

How to Create a.cibd/.cce File from Mentor Xpedition for HLDRC

Migration Guide: Numonyx StrataFlash Embedded Memory (P30) to Numonyx StrataFlash Embedded Memory (P33)

Intel Desktop Board D915GUX Specification Update

Intel Cluster Ready Allowed Hardware Variances

Intel Desktop Board D915GEV Specification Update

Intel Desktop Board DX48BT2. MLP Report. Motherboard Logo Program (MLP) 6/17/2008

Intel Setup and Configuration Service. (Lightweight)

Intel Server Board S2600JF Intel Server System H2600JF

Intel Desktop Board DG35EC. MLP Report. Motherboard Logo Program (MLP) 6/17/2008

Installation Guide and Release Notes

Intel Education Theft Deterrent Release Note WW16'14. August 2014

Intel Desktop Board DH61CR

Desktop/Motherboard WHC Report

BIOS Update Release Notes

Clear CMOS after Hardware Configuration Changes

BIOS Update Release Notes

Intel Desktop Board D945GCLF

BIOS Update Release Notes

True Scale Fabric Switches Series

BIOS Update Release Notes

Intel Desktop Board DH61SA

BIOS Update Release Notes

Intel Desktop Board D946GZAB

Intel Server Platform SR6850HW4M & SR4850HW4M

Intel X48 Express Chipset Memory Controller Hub (MCH)

Intel Desktop Board D975XBX2

Intel Platform Memory Operations

Intel Desktop Board D102GGC2 Specification Update

BIOS Update Release Notes

BIOS Update Release Notes

Intel RealSense Depth Module D400 Series Software Calibration Tool

Intel Server RAID Controller U2-1 Integration Guide For Microsoft* Windows NT* 4.0

Intel Desktop Board D945GCLF2

Intel Desktop Board DP67DE

Intel Server Board S3000PT Spares/Parts List and Configuration Guide for Production Products

Non-Volatile Memory Cache Enhancements: Turbo-Charging Client Platform Performance

BIOS Update Release Notes

BIOS Update Release Notes

Intel Desktop Board D945GCCR

BIOS Update Release Notes

Intel Desktop Board D845PT Specification Update

Intel Storage System SSR212MA

Intel Desktop Board DX58SO. MLP Report. Motherboard Logo Program (MLP) 8/10/2009

Intel IXP42X Product Line of Network Processors and IXC1100 Control Plane Processor: Boot-Up Options

BIOS Update Release Notes

Intel Workstation Board S5000XVNSATAR

Intel Desktop Board DH55TC

Intel Serial to Parallel PCI Bridge Evaluation Board

Intel Desktop Board DP55SB

Intel NUC Install Windows* 7 from USB Drives onto USB 3.0 Computers

Intel Learning Series Developer Program Self Verification Program. Process Document

Intel Server Board S5000VCL

Intel Server board S5520HC

BIOS Update Release Notes

Intel Desktop Board DQ35JO

Intel Unite Plugin Guide for VDO360 Clearwater

Boot Agent Application Notes for BIOS Engineers

Intel Desktop Board DP55WG. MLP Report. Motherboard Logo Program (MLP) 8/31/2009

Intel Turbo Memory. Release Notes. October Revision

Transcription:

Intel SRCS28X RAID Controller 814G Firmware Upgrade for Intel Storage System SSR316MJ+ Firmware Release Notes Revision 1.0

October, 2006 Storage Systems Technical Marketing 2

Revision HistoryIntel SRCS28X RAID Controller 814G Firmware Upgrade for Intel Storage System SSR316MJ+ Revision History Revision Date Number October, 2006 1.0 1 st Release copy. Modifications iv October, 2006

Intel SRCS28X RAID Controller 814G Firmware Upgrade for Intel Storage System SSR316MJ+Disclaimers Disclaimers THE INFORMATION IN THIS DOCUMENT IS PROVIDED "AS IS" WITH NO WARRANTIES WHATSOEVER, INCLUDING ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR ANY PARTICULAR PURPOSE, OR ANY WARRANTY OTHERWISE ARISING OUT OF ANY PROPOSAL, SPECIFICATION, OR SAMPLE. Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel retains the right to make changes to its test specifications at any time, without notice. The hardware vendor remains solely responsible for the design, sale and functionality of its product, including any liability arising from product infringement or product warranty. Copyright Intel Corporation 2006. All rights reserved. Intel, the Intel logo, and EtherExpress are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. *Other names or brands may be claimed as the property of others. October, 2006 v

troller 814G Firmware Upgrade for Intel Storage System SSR316MJ+ Table of Contents 1 Introduction... 7 2 Summary of Issues Fixed in This Release... 7 3 Upgrading to 814G Firmware... 8 3.1 Applying This Upgrade... 8 3.1.1 Upgrade Overview... 8 3.1.2 Prerequisites... 8 3.1.3 Download the Upgrade Components... 8 3.2 Installing the 814G RAID Controller Upgrade... 9 3.2.1 Best Practices... 9 3.2.2 Selecting The Type of Upgrade... 9 3.2.3 Intended Upgrade Canadiates... 9 3.2.4 Determining RAID Controller Firmware Versions... 10 3.2.5 Upgrade Procedures... 10 vi October, 2006

Intel SRCS28X RAID Controller 814G Firmware Upgrade for Intel Storage System SSR316MJ+ Introduction 1 Introduction The Intel SRC28X RAID Controller firmware upgrade to 814G should look and feel like any other Intel Storage System SSR316MJ+ software upgrade. However, because we are updating lowlevel firmware on two printed circuit cards residing on the PCI bus there are some notable exceptions to the standard upgrade process. Please carefully review this document in its entirety before proceeding to the actual upgrade. 2 Summary of Issues Fixed in 814G Firmware 3951: When drive goes bad, MegaRAID fails and no communication is possible with the controller 4254: Battery Status briefly goes to charging 4289: Spurious hi temp event 4360, 4496: RAID controllers go offline or take disk set offline 4867: Cache re-enabled when BBU voltage is still recharging 4947: RAID controllers go offline 4987: Backend performance tests showed > 50% variation from reboot to reboot 5041: MegaRAID fails during I/O and 2-way replication fails 5070: Controller goes offline when doing I/O for extended time 5096: After completing charging, controller cache doesn t turn on for some time 5118: Under heavy loads, MegaRAID aborts operations October, 2006 7

Intel SRCS28X RAID Controller 814G Firmware Upgrade for Intel Storage System SSR316MJ+ 3 Upgrading to 814G Firmware 3.1 Applying This Upgrade 3.1.1 Upgrade Overview Order of Upgrade for Intel Storage System SSR316MJ+s running Storage System Software 6.3, 6.3 SP1 or 6.5 Release 1) First upgrade to firmware version 814G 2) Then upgrade to latest available software release 3.1.2 Prerequisites If you are planning to implement RAID 5 or RAID 10 levels the configuration must be done at lease 24 hours prior to 814G firmware upgrade. Reason being, for a period of approximately 24 hours following a RAID 5 or RAID 10 configuration, the system performs background initialization and consistency checks in the RAID controllers. If you attempt to perform the upgrade during this initialization the Storage System Management Console will refuse to proceed with the upgrade. All Intel Storage System SSR316MJ+s being upgraded must have RAID levels configured with a status of Normal before proceeding to upgrade. The storage module will reboot as part of the upgrade process which will cause your volumes to temporally go offline. If any iscsi volumes are in use, please stop activities to those volumes by either unmount or logging off before beginning the upgrade. 3.1.3 Download The Upgrade Components 1. Download the Intel SRCS28X RAID controller 814G firmware upgrade package from the Intel Storage System SSR316MJ+ support site or from your IBL account. Platform For RAID Controller Firmware Version Use Upgrade File SSR316MJ+ 814G Intel RAID firmware 814G-2.20.4.8 20060927.install 8 October, 2006

Intel SRCS28X RAID Controller 814G Firmware Upgrade for Intel Storage System SSR316MJ+ Upgrading to 814G Firmware 3.2 Installing the 814G RAID Controller Firmware 3.2.1 Best Practice Virtual IP Addresses - If a Virtual IP (VIP) address is assigned to a storage module in a cluster, the VIP storage module needs to be upgraded last. The VIP storage module is shown in a field in the clusters detail tab. o o First upgrade the non-vip storage modules that are running managers one at a time. Then upgrade the non-vip non-manager storage modules. o Lastly, upgrade the VIP storage module. Remote Copy If you are upgrading management groups with Remote Copy associations, you must upgrade the remote management group first. If you upgrade the primary group first, Remote Copy will stop working. 3.2.2 Selecting the Type of Upgrade The Storage System Software Console supports two types of upgrades One-at-a-time (recommended) - this is the default and only method if the storage modules exist in a management group. Simultaneous (advanced) - this allows you to upgrade multiple storage modules at the same time if they are not in a management group. Use this for new storage modules and/or reconfigured storage modules. 1. Select from the list which storage modules to upgrade. 2. Select the type of upgrade. 3. Click Install. 3.2.3 Intended Upgrade Candidates Intel 814G firmware upgrade candidates will fall into one of two categories Category 1 Upgrades for customers with production Intel Storage System SSR316MJ+s with RAID levels currently configured and containing live data. This category will include Intel Storage System SSR316MJ+s that are in a management group, cluster and have customer accessible live volumes. Category 2 Upgrades for customers with delayed installation; Intel Storage System SSR316MJ+s that are still in the carton and need to have their Intel SRCS28X RAID controller firmware updated to 814G at installation time. This category will include Intel Storage System SSR316MJ+s that were manufactured with 814C or earlier firmware versions loaded into the RAID controllers but have not been deployed in a production environment. October, 2006 9

Upgrading to 814G Firmware Storage System SSR316MJ+ Intel SRCS28X RAID Controller 814G Firmware Upgrade for Intel 3.2.4 Determining RAID Controller Firmware Version Please use the passive report tool to determine your current Intel SRCS28X RAID controller firmware version. The section in the report for NVRAM items will display the firmware version. The Intel Storage System SSR316MJ+s contain two Intel SRCS28X RAID controllers so please be sure to check both firmware versions to avoid performance issues. 3.2.5 Upgrade Procedures Procedures for Category 1 1. Using the passive reports, please verify that the Intel SRCS28X RAID controller firmware version is 814C or earlier. 2. Perform the firmware upgrade and reboot. 3. After the upgrade finishes and the storage module has rebooted, use the passive reports to verify that both controllers have firmware version 814G. Clustered Intel Storage System SSR316MJ+s with 2-way replication turned on 1. Using the passive reports, please verify that the Intel SRCS28X RAID controller firmware version is 814C or earlier. 2. Perform the firmware upgrade and reboot. 3. After the upgrade finishes and the storage module has rebooted, use the passive reports to verify that both controllers have firmware version 814G. 4. Next, wait for the storage module to resynchronize. 5. Once the resynchronization finishes, upgrade the next storage module in the cluster. 6. Repeat steps 1 through 5 until you have upgraded all the storage modules in the cluster. Procedures for Category 2 1. Power on the storage module. 2. Wait 24 hours for the background initialization to complete. 3. Using the passive report, please verify that the Intel SRCS28X RAID controller firmware version is 814C or earlier. 4. Perform the firmware upgrade and reboot. 5. After the upgrade finishes and the storage module has rebooted, use the passive reports to verify that both controllers have firmware version 814G. Note: In some rare cases, successfully upgraded firmware on the Intel SRCS28X RAID controller will cause a CRC failure or md5 checksum on the boot cycle that follows the upgrade. The controllers then safely revert to its previous firmware revision. The reversion is harmless and if it occurs please try the upgrade again. 10 October, 2006