6215L Inline & NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Similar documents
/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface

G 1/2 30,5 A Brass NBR 0,8 3,

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

98025 NAMUR 3/2 poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

Operating pressure. N/en/en

26360, 80207, 3/2, 5/2 & 5/3 Indirect solenoid actuated spool valves

Flow. (l/min) (ms) N/en

Operating pressure (bar)

Operating pressure. N/en/en

Technical features. N/en

97105 NAMUR, 3/2, 5/2 & 5/3 Indirect electromagnetic actuated spool valves

80265 series, 3/2 Indirect solenoid actuated poppet valve

Technical features. 12/ f. N/en

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

V88 series Redundant valve manifold systems - Semi modular 2oo2 Availability

Operating pressure (bar) kv factor (m 3 /h) *3)

V88 series Redundant valve manifold systems - Semi modular 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Series 95000, 2/2 Direct solenoid actuated poppet valve

3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface

95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

21023, 21025, 2/2 Direct solenoid actuated poppet valves

Flow. Flow. N/en

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

24011 series, 3/2 Direct solenoid actuated poppet valve

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7

98015 series, 3/2 Direct solenoid actuated poppet valve

Material Seat seal. N/en

Material pressure (bar) (Cv (US) kv x 1,2 Seat

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

26360, NAMUR. Technical data

97105 Inline, 3/2 & 5/2 Direct pneumatically actuated spool valves

60 series, 2/2 or 3/2 Ball valve

SCVA08, SCVA10, SCVA20 & SCVA32, 3/2 Solenoid actuated safety valve

26230, Inline 3/2, 5/2 and 5/3 way soft seal spool valves electromagnetic actuated, indirectly controlled G 1/4, G 1/2

ISO*STAR (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves

ICO3S - 2/2, 3/2 or 5/2 poppet valves Electromagnetically actuated, direct solenoid operated

ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled

97105 Inline direct pneumatically actuated 3/2 and 5/2 spool valves G 1/4.G1/2, 1/4 NPT 1/2 NPT

V87 series - Redundant valve manifold systems - Semi modular 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

B64G - Olympian Plus plug-in system Filter/regulator

SPCH/ Big bottle blowing block

21D Allfluid pressure switch, electromechanically actuated

HERION SERIES Indirect solenoid actuated spool valves

15 and 16 Series BSP and hose fittings

RM/92000/M, Short stroke cylinder Magnetic piston, double acting

M/60100/M, Slide units Magnet piston, double acting

ISO*STAR - ATEX version (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves

LB74G - EXCELON Modular System General purpose filter/regulator

VCB22, 5/2 Solenoid actuated In-line spool valves

RM/28000/M, ISO cylinder Magnetic piston, single acting

R./57100/M, R./57300/M, Roundline cylinder Magnetic piston, single acting

V03, V04 and V05 Series

PNEUFIT 10 series Push-in fittings

BSP & HOSE Fittings M5, 1/8... 1

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.

10 series (Pneufit) Push-in fittings Ø mm O/D tube, BSP threads

10 series (Pneufit) Push-in fittings Ø mm tube size, BSP threads

Pneumatic Control/Feedback

Pneumatic Control/Feedback

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s

RT2E Compact temperature switch Explosion proof

Pneumatic Control/Feedback

Direct solenoid and solenoid pilot operated valves

RT2Y Compact temperature switch intrinsic safety

Compression Fittings 34 Series Inch

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

Direct solenoid and solenoid pilot operated valves

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

3/2 5/2 SERIES 362/562

Solenoid Valves PN16 for gas flow interception

MPreC - Pressure Relief Device Order specification sheet

Pneumatic Control Unit for the integrated mounting on process valves

Direct solenoid and solenoid pilot operated valves

T EN TROVIS Electropneumatic Positioner

Control Head for the integrated mounting on process valves

Immersion Temperature Sensors

Control Head for the integrated mounting on process valves

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)

Electro-pneumatic control valves

Control Head for the integrated mounting on process valves

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication

Pilot operated 2 port solenoid valve (general purpose valve) 100 VAC 50/60Hz 110 VAC 60Hz 200 VAC 50/60Hz 220 VAC 60Hz 12 VDC 24 VDC 48 VDC 100 VDC

Cable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof

Block diagram MB-VEF

Series 3730 Type Electropneumatic Positioner

Digital electropneumatic Positioner for the integrated mounting on process control valves

5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4

Double piston cylinder, Series TWC Ø6-32 mm double-acting with magnetic piston cushioning: elastic

M3P..G/A, M3P..F/A Modulating control valves (PN16) for chilled and hot water systems

Old documentation - Only for your information! Product is not available anymore!

Technical Information Promonitor NRF560

Radiator Valves. Building Technologies HVAC Products. NF norm, for 2-pipe heating systems

Digital electropneumatic Positioner for the integrated mounting on process control valves

Series 3730 Type Electropneumatic Positioner

Digital electropneumatic Positioner for the integrated mounting on process control valves

Limit Switch Box YT-870/875 SERIES

Transcription:

L Inline & NMUR series, / & / > Port size: / (ISO /NPT) or flanged with NMUR interface > Suited for outdoor use under critical environment conditions (see solenoid list) > Variable valve solenoid combination > pplicable in the protection classes Ex e mb, Ex d mb, Ex mb for zones & (gas), & (dust), TEX cat. II D > International approvals: TEX, IEEx, NEPSI, others on request Technical features Medium: Filtered, nonlubricated and dried compressed air Operation: Indirect solenoid operated spool valve Operating pressure:,... bar (... psi) with internal air supply Port size: /, / NPT or NMUR Interface Flow direction: Fixed Mounting position: Optional, impulse valves preferably horizontally mbient/media temperature:... + (... + F) Depending on solenoid system ir supply must be dry enough to avoid ice formation at temperatures below +. For outdoor installations must be protected all connections against the penetration of moisture and a solenoid with IP protection must be used! Material: ody: luminum with surface treatment for critical environmental conditions Seals: Special NR Flow conversion: v US allon/min (water) = l/min (air) x, Kv m³/h (water) = l/min (air) x,9 Technical data / and / way valves Inline Housing: luminium anodized, Seals: NR... + (... + F) Symbol Port size Function ctuation/ return Flow (l/min) Operating pressure (bar) Weight (kg) Dimension *) / /,...,9 L / NPT /,...,9 L / /,..., L / NPT /,..., L *) When ordering please indicate solenoid, voltage and current type (frequency) / and / way valves NMUR Housing: luminium anodized, Seals: NR... + (... + F) Symbol Ports,,, ctuation/ return Flow (l/min) Operating pressure (bar) Weight (kg) Dimension *) / Flange 9,... L / NPT Flange 9,... L *) When ordering please indicate solenoid, voltage and current type (frequency) Valve function: / or / way function (onversion instructions see page ) without notice, the specifications given in this document. ( 9a) Norgren Ltd. / S/en...

L Inline & NMUR series, / & / Option selector Power consumption L Voltage M V D Low (. W) L V Function Medium (.9 W) V and V are available on request / spring return (/ way with adapter plate for NMUR flange) / spring return (Inline) Ports size / Namur / NPT Namur / Inline / NPT Inline Material / Seals Solenoid actuators luminium/nr... + Version With / turn manual override Solenoids group, standard voltages Power consumption Rated current Protection class V d.c. (W) V a.c. (V) V d.c. (m) V a.c. (m) IP/NEM IP, IP IP,,, ExProtection (TEXategory) Temperature Electrical mbient/media connection Weight Drawing ircuit diagram ( ) (kg) II Ex e mb II T/ IID Ex tb IIIT II Ex e mb II T/ IID Ex tb IIIT II Ex d mb II T/ II Ex e mb II T/ IID Ex tb IIIT T:...+ T:... +...+ M x, *), T:...+ T:... +...+ M x, *), T:...+ T:... +...+ / NPT *) IP II Ex d mb II T/ II Ex e mb II T/ IID Ex tb IIIT T:...+ T:... +...+ M x, *) IP II Ex d mb II T/ II Ex e mb II T/ IID Ex tb IIIT T:...+ T:... +...+ / NPT *) IP II Ex d mb II T/ II Ex e mb II T/ IID Ex tb IIIT T:...+ T:... +...+ M x, *) 9, X,, P,, 9 II Ex mb d II T/T... + II EX mb e II T/T II D Ex td a Flying leads mm, Standard voltages (±%) V d.c., V a.c., other voltages on request. Design according to VDE, EN /. % duty cycle. *) onnector/cable gland is not scope of delivery, see table»ccessories«ttention: The protection class for coil series xx and xx is determined by the choice of cable gland. Example: if an TEXcertified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb. S/en... without notice, the specifications given in this document. ( 9a) Norgren Ltd. /

L Inline & NMUR series, / & / pprovals pprovals TEX IEEx FM Datasheet x, x SLR xx KEM 9 TEX X IEEx KEM 9.X N/en.. xx PT TEX X IEEx PT.9X N/en.. N/en.. ccessories Electrical connection able gland Protection class Ex e, Ex d Page Thread able Ø (mm) Materials Protection class (TEX) M x,... Nickel plated brass II D Ex e 9 M x,... Nickel plated brass II D Ex d / NPT,...,9 Nickel plated brass II D Ex d 9 M x, 9... Stainless steel. ( Ti) II D Ex e 9 M x,... Stainless steel. ( L) II D Ex d 99 M x,... Stainless steel. ( L) II D Ex d 9 Valve daptor complete (daptor, inlet filter and seal ring) Inlet filter Silencer (plastic) *) Silencer (stainless steel) Silencer (brass) *) *) Exhaust guard *) Page Page Page Page Page Page (/) (/, / NPT) M/S (/) (/) T (/) (/, / NPT) /S (/ NPT) (/ NPT) MS (/ NPT) *) For indoors use only *) For outdoors use, opening pressure ~, bar onversion plate Page Z / without notice, the specifications given in this document. ( 9a) Norgren Ltd. S/en...

L Inline & NMUR series, / & / Drawings Dimensions in mm angleangle Valves / way Inline ~ 9. 9 9. / Inline ~ 9. 9. / way NMUR ~ 9. 9. S/en... Manual override Hole Ø. Hole Ø 9. x, deep without notice, the specifications given in this document. ( 9a) Norgren Ltd. /

,, Dimensions in mm angleangle 9, ±, Drawings Solenoid,,, L Inline & NMUR series, / & / 9,,, 9, 9, Ø or (with spacer tube) M x, or / NPT,,, / NPT, ±,,, 9, / NPT Ø or (with spacer tube) M x, or / NPT Flying leads W ( mm long), ircuit diagrams T / T without notice, the specifications given in this document. ( 9a) Norgren Ltd. S/en...

L Inline & NMUR series, / & / NMUR hole pattern (driving side) Port size / M Port () Hole for coding stud M & M ( deep) Port (R) onversion instructions of / into / way function / way function (original mode of supply) / way function / / / resp. / way function according to version by swapping or turning enclosed adaptor plates. Make sure Marker and rrow do match as shown on above drawing. rrow Marker onversion plate : Z x ø, mm S/en... without notice, the specifications given in this document. ( 9a) Norgren Ltd. /

L Inline & NMUR series, / & / daptor complete Inlet filter : : Dimensions in mm angle angle,,,,, Ø,, Ø, /, / 9 / /,,, Thread pitch diameter max., mm Silencer (plastic) Exhaust guard : M/S, M/S, /S : ød ød ØD Weight (g) Suitable for ØD Weight (g) /,,,9 M/S / /, / NPT, / NPT,,,9 /S able gland D D ød 9... 9 M x,,, 9... 9 M x, 9... / NPT,...,9 9 M x, 9... 99 M x,... 9 Weight (g) / T / NPT 9/ MS / *) / NPT *) D M x, D 9 only Silencer (brass or stainless steel) *) Stainless steel EN Englisch Warning These products are intended for use in industrial compressed air and fluid systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features/data«. efore using these products with fluids other than those specified, for nonindustrial applications, lifesupport systems, or other applications not within published specifications, consult IMI Precision Engineering, Norgren Ltd. / Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. without notice, the specifications given in this document. ( 9a) Norgren Ltd. S/en...