EA10: System Checkout, Test, and Startup Pre-Instructional Survey
|
|
- Roy Malone
- 5 years ago
- Views:
Transcription
1 EA10: System Checkout, Test, and Startup Pre-Instructional Survey Name Date CFR describes a change as: a. Any action that constitutes a serious event b. Any action that could create an injury c. Anything but an in-kind replacement d. Any non-technical process change 2. The level of risk is determined by determining the event frequency and the: a. Actual threat implied by an action b. Consequences of the occurrence c. Averaging event frequencies d. Results of risk reduction 3. Safety Shutdown Systems are (in most instances) best a. Totally integrated with the BPCS b. Engaged with a DCS/SIS system c. Kept only in pneumatic devices d. Kept separated from the BPCS 4. A safety system labeled 1oo2D means a. One out of two with diagnostics b. One thousand two deficiencies c. Differential of one out of two d. Voting on errored outputs 5. Shut down procedures are used: a. By management for cost estimation b. Primarily to protect process and materials c. Only after acceptance and in normal operations d. To reduce or eliminate process energy to safe levels 1
2 6. The objectives of Receipt Verification (RV) are: a. Verify the device received is that which was ordered b. Correct vendor manuals received with the equipment c. Device meets specification for that instrument d. All of the above 7. Receipt Verification may be performed a. On-site b. Vendor s site c. Third party site d. Any of the above 8. Manufacturer s manuals can be a. Traditional print materials b. Computer-stored text file c. Adobe.pdf files d. Any of above above 9. Installation Verification is performed to a. Correctly assess risk and risk occurrences in operation b. Ensure the items have been received in proper order c. Provide a phase of instrument commissioning d. Provide final acceptance of system 10. Calibration is used to check a device (or bring a device to) a. Heterogeneity b. Homogeneity c. Specification d. Deviation 11. The form of calibration most often used in process control is: a. Derived b. Inferred c. Deduction d. Comparison 2
3 12. Calibration is essential in checkout, system test and startup because a. System dynamics depend on accurate measurement and outputs b. Of the need to prove the cost effectiveness of the different devices c. It reduces the device power required and enhances energy efficiencies d. Allows documentation of each instrument so accountability is increased 13. Loop Checking is a process of validating a. Terminations, wiring, documentation, device placement b. Calibration, receipt verification, loop tuning, documentation c. Site acceptance testing, operating procedures, device placement d. Factory acceptance testing, documentation, operating procedures 14. The Installation Detail Diagram gives information about a. General assembly and installation instructions b. Altitude, FPI, piping locations, and FP positions c. Specific installation details of an individual device d. Piping, instrumentation, and documentation diagrams 15. On an electrical loop diagram, squares are used to indicate a. Terminations b. Setpoint values c. Conductor size d. Junction boxes 16. A loop diagram contains information about a. A single loop from measurement to controller to final control element b. Multiple loops from intermediate frame through final control element c. The measurement side of the loop including calibration points and terminals d. The control side of the loop including transforms and calibration instructions 17. According to IEC a PLC is programmed in a. Any of the below b. Function blocks c. Ladder logic d. SFC 3
4 18. On an AI there will be a 250 ohm resistor. The function of this resistor is a. I/P b. E/I c. E/P d. I/E 19. When using a laptop with a 202 Modem and the HART protocol to check smart instruments, in order to test the instrument a. Loop power must be removed entirely b. There may be partial loop power c. The loop must be fully powered d. A loop reflector must be used 20. Software testing will be greatly facilitated if the vendor uses a. A software assurance program b. Procedural language c. Multiple exit loops d. COBOL coding 21. Factory Acceptance Testing is performed when the a. System has been delivered and supplier is ready to test b. System has been delivered and the user is ready to test c. System has been built and has its performance tested d. System has been built; the supplier is ready to deliver 22. Site Acceptance Testing is the point that allows testing of the a. Operational status of materials and devices received during the IV stage b. Interface with Level 3 (MES) and Level 4 (ERP) systems (if applicable) c. The documentation from RV through IV and loop test d. SIS-only portions of the BPCS for installation and operation faults 23. When performing any of the stages of checkout, system test, and startup a. Documenting minor deviations is not of importance b. Storing documents on microfiche is the current methodology c. Documentation should be kept in a central location, preferably computer d. Databases should only be used if the maintenance manager is a programmer 4
5 24. When testing alarms and interlocks, tests should be performed with the system parameters a. Out-of-bounds first and then in-bounds b. In-bounds first and then out-of-bounds c. No bounds first and then max deviation d. Max deviation first and then no bounds 25. Function blocks which are reusable software components are derived from a. Object-oriented programming b. Procedural coding c. Visual Basic 3.0 d. OPC 26. During startup, safety is a. Of little concern due to the installation verification and loop testing performed b. Of some concern because of the catastrophic results attainable with new units c. Primary concern because many operational parameters have not been tested d. Primary concern because of possible bad public relations if a release occurs 27. Written polices and procedures are necessary for each action taken because a. Procedure writers are technically knowledgeable in the process b. In case of detrimental results, responsibility can be placed reliably c. They provide a consistent, uniform, and legal set of actions and definitions d. Management has issued an ultimatum that procedural actions must be correct 28. Writing and testing application software is difficult because of the a. Complexity of the underlying layers of software b. Lack of crude compilers that are currently available c. Redundancy; writing software is always tedious and difficult d. Long hours necessary for compiling and recompiling the code 5
6 29. Layers of Protection as a safety philosophy works because a. It has sufficient complexity that laypeople will not understand it b. Each layer supplies its own independent and differing degree of protection c. Each succeeding layer out tightens the constraining index of RE applications d. The color-coded layers make it easy for under stress persons to easily recognize 30. Technical procedures are best developed by a. Individual use and development b. Sole authority as directed c. Management fiat then use d. Consensus and then test 6
7 EA10: System Checkout, Test, and Startup Answers for Pre-Instructional Survey 1. c 2. b 3. d 4. a 5. d 6. d 7. d 8. d 9. b 10. c 11. d 12. a 13. a 14. c 15. a 16. a 17. a 18. d 19. c 20. a 21. d 22. b 23. d 24. b 25. a 26. c 27. c 28. a 29. b 30. d 7
Safety Instrumented Systems: Can They Be Integrated But Separate?
Safety Instrumented Systems: Can They Be Integrated But Separate? Written by Merry Kuchle and Trevor MacDougall of Spartan Controls. For questions, please contact Robert Smith. Keywords Safety Instrumented
More informationT72 - Process Safety and Safety Instrumented Systems
T72 - Process Safety and Safety Instrumented Systems Comprehensive Solutions Portfolio for Fail-Safe to TMR Safety Applications PUBLIC Copyright 2018 Rockwell Automation, Inc. All Rights Reserved. 1 Agenda
More informationED17: Architectures for Process Safety Applications
ED17: Architectures for Process Safety Applications Name Pete Skipp Title Process Safety Architect Date November 5 th & 6 th 2012 Copyright 2012 Rockwell Automation, Inc. All rights reserved. Agenda An
More informationT57 - Process Safety and Critical Control What Solution Best Meets Your Needs?
PUBLIC - 5058-CO900H T57 - Process Safety and Critical Control What Solution Best Meets Your Needs? PUBLIC PUBLIC Agenda Introduction To Process Safety Process Safety and Machine Safety Things to Consider
More informationType 9160 / Transmitter supply unit / Isolating repeater. Safety manual
Type 9160 / 9163 Transmitter supply unit / Isolating repeater Safety manual Safety manual English Content 1 General information... 3 1.1 Manufacturer... 3 1.2 Information regarding the Safety Manual...
More informationA Guide to the Automation Body of Knowledge
A Guide to the Automation Body of Knowledge 2nd Edition Vernon L. Trevathan, Editor Table of Contents Preface, xv Basic Continuous Control, 1 1 Process Instrumentation, 3 1.1 Introduction, 3 1.2 Pressure,
More informationand Emerging Instrument Technologies
FLUOR and Emerging Instrument Technologies SmartPlant Implementation Team By John Dressel The Challenge of Emerging Technologies New and emerging technologies bring new challenges to the Instrumentation
More informationInnovation for system integration
Innovation for system integration PERFORMANCE MADE SMARTER PR backplane A user-friendly and reliable mounting solution between the DCS/PLC/SIS system and isolators/i.s. interfaces TEMPERATURE I.S. INTERFACES
More informationSIS Operation & Maintenance 15 minutes
2005 Emerson Process Management. All rights reserved. View this and other courses online at www.plantwebuniversity.com. SIS 301 - Operation & Maintenance 15 minutes In this course: 1 Overview 2 Planning
More informationFunctional Safety Processes and SIL Requirements
Functional Safety Processes and SIL Requirements Jordi Campos Tüv Süd Process Safety Business Manager Jordi.campos@tuev-sued.es 15-07-14 Terminology Safety Instrumented Systems (SIS) Safety Integrity Level
More informationFIRELEC Migration Solution. PROVOX > DeltaV. PIA (PROVOX Interface Adapters) FMS-PVXCL-DV-2. Analog Inputs
Rev : 2014_06 Migration Solution PROVOX > DeltaV PIA (PROVOX Interface Adapters) FMS-PVXCL-DV-2 Analog Inputs Migration Solution FMS-PVXCL-DV-2 Réf. : TABLE OF CONTENTS INTRODUCTION... 3 1.1. KEY ADVANTAGES
More informationH1 + HSE FFB Integrated Architecture Demonstration
WHITE PAPER FOUNDATION Fieldbus H1 + HSE FFB Integrated Architecture Demonstration International Specialty Products (ISP) Lima, Ohio Abstract What End Users have asked for The challenge facing industry
More information1.6 Configuring Intelligent Devices
1.6 Configuring Intelligent Devices J. BERGE (2003) DESIGN FEATURE RECOMMENDATIONS Use permanently connected communications infrastructure. For the HART Field Communications Protocol, use a handheld with
More informationSCADA Software. 3.1 SCADA communication architectures SCADA system
3 SCADA Software 3.1 SCADA communication architectures 3.1.1 SCADA system A supervisory control and data acquisition (SCADA) system means a system consisting of a number of remote terminal units (RTUs)
More informationFSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1
FSO Webnair FSO Safety Functions Module February 11, 2015 Slide 1 Competence Requirements for ABB Commissioner / Service Engineer of ACS880 Drives with FSO The integrated Safety Function Module (FSO; option
More informationSmart Wireless THUM Adapter
Reference Manual Smart Wireless THUM Adapter www.rosemount.com Reference Manual Smart Wireless THUM Adapter Smart Wireless THUM Adapter Smart Wireless THUM Adapter Hardware Revision 1 HART Device Revision
More informationConverter SINAMICS G150. Type 6SL37102G
Tests carried out on drives This documentation pertains to LV Umrichter E11 F72 F76 F79 L45 L50 L57 L68 M54 U11 Reference Manual Converter SINAMICS G150 Type 6SL37102G Edition 02/2019 www.siemens.com/drives
More informationRisk Assessment Methodologies. Michele M. Silva Solution Architect, Safety & Security Functional Safety Engineer (TUV Rheinland)
Risk Assessment Methodologies Michele M. Silva Solution Architect, Safety & Security Functional Safety Engineer (TUV Rheinland) Agenda Introduction to Standards Functional Safety Design Process Risk Assessment
More informationHART COMMUNICATION. A Digital Upgrade For Existing Plants
HART COMMUNICATION 1. The majority of smart field devices installed worldwide today are HART-enabled. But some new in the automation field may need a refresher on this powerful technology. Simply put,
More informationSupplement to Fisher FIELDVUE DVC6000 SIS Series Digital Valve Controllers for Safety Instrumented System (SIS) Solutions Instruction Manual
Instruction Manual Supplement D103395X012 DVC6000 SIS Supplement to Fisher FIELDVUE DVC6000 SIS Series Digital Valve Controllers for Safety Instrumented System (SIS) Solutions Instruction Manual Control
More informationDeltaV SIS Standalone
DeltaV SIS Process Safety System White Paper January 2018 DeltaV SIS Standalone This whitepaper provides an overview of Emerson s DeltaV TM SIS standalone solution. To 3rd Party BPCS DeltaV SIS Standalone
More informationDevice Management System [R 41]
No. SS2-IFO410-0001 (Edi. 1) Device Management System [R 41] What is InnovativeField Organizer? InnovativeField Organizer (hereinafter IFO) is a device management system for smart field devices that supports
More informationPoint Level Transmitters. Pointek CLS200 (Standard) Functional Safety Manual 02/2015. Milltronics
Point Level Transmitters Pointek CLS200 (Standard) Functional Safety Manual 02/2015 Milltronics Introduction 1 General safety instructions 2 Pointek Level Instruments Device-specific safety instructions
More informationCOMMON CAUSE AND COMMON SENSE
COMMON CAUSE AND COMMON SENSE Designing Failure Out of Your SIS Angela E. Summers, Ph.D., P.E. and Glenn Raney Common Cause and Common Sense Designing Failure Out of Your SIS, ISA EXPO 1998, Houston, Texas,
More informationICS Regent. Communications Package for W INTERPRET. Guarded Peer-Link Communications (T3831) PD-6041
ICS Regent PD-6041 Communications Package for W INTERPRET Guarded Peer-Link Communications (T3831) Issue 1, March, 06 The WINTERPRET Communications Package is an add-in software package that allows you
More informationsmar First in Fieldbus Architecture Description Applications Engineering Department International Division 1
Architecture Description 1 This report briefly presents the key components of Smar System302, which can be found in the typical architecture illustrated in the next figure. Operation Workstation: ProcessView
More informationDeltaV SIS TM. Logic Solver. DeltaV SIS Logic Solver. Introduction. DeltaV SIS Product Data Sheet. World s first smart SIS Logic Solver
February 2016 Page 1 DeltaV SIS TM Logic Solver The DeltaV SIS platform is the world s smart SIS system to use the power of predictive intelligence for increasing the availability of the entire safety
More informationUsing smart field devices to improve safety system performance
Using smart field devices to improve safety system performance Safety monitoring software can use data from smart field devices to improve safety system performance and operation By Guillermo Pacanins,
More informationPractical Programmable Logic Controllers (PLCs) for Automation and Process Control. Contents
Practical Programmable Logic Controllers (PLCs) for Automation and Process Control Contents 1 Introduction to the PLC 1 1.1 Introduction 1 1.2 Basic Block Diagram of the PLC 2 1.3 Size of the PLC System
More information2oo4D: A New Design Concept for Next-Generation Safety Instrumented Systems 07/2000
2oo4D: A New Design Concept for Next-Generation Safety Instrumented Systems 07/2000 Copyright, Notices and Trademarks 2000 Honeywell Safety Management Systems B.V. Revision 01 July 2000 While this information
More informationHI HIPS Logic Solver (2oo3)
General Specifications GS48C00Z00-00E-N HI-100-00 HIPS Logic Solver (2oo3) INTRODUCTION HIPS is the abbreviation for High Integrity Protection System. A HIPS is a specific application of a Safety Instrumented
More informationFailure Modes, Effects and Diagnostic Analysis. Rosemount Inc. Chanhassen, MN USA
Failure Modes, Effects and Diagnostic Analysis Project: 8732C Magnetic Flow Transmitter Customer: Rosemount Inc. Chanhassen, MN USA Contract No.: Ros 03/07-26 Report No.: Ros 03/07-26 R001 Version V1,
More informationhttps://support.industry.siemens.com/cs/ww/en/view/
Wiring and Voting Architectures for failsafe Analog Input Modules (F AI) of the ET 200M SIMATIC Safety Integrated for process automation https://support.industry.siemens.com/cs/ww/en/view/24690377 Siemens
More informationBRIDGING THE SAFE AUTOMATION GAP PART 2
BRIDGING THE SAFE AUTOMATION GAP PART 2 Angela E. Summers, Ph.D., P.E., President, SIS-TECH Solutions Bridging the Safe Automation Gap Part 2, 2002 Instrumentation Symposium, Texas A&M University, College
More informationIntegrated and Separate?
Integrated and Separate? A document to aid the demonstration of Independence between Control & Safety by The 61508 Association Overriding key principle...it must be safe! DISCLAIMER: Whilst every effort
More informationPRM Integration Guide with. MTL 4840 Series HART Multiplexer
PRM Integration Guide with MTL 4840 Series HART Multiplexer This manual explains how to connect the MTL4840 Series HART Multiplexer and configure Yokogawa s Plant Resource Manager (PRM) software. This
More information1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882
1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature
More informationSECTION MICROPROCESSORS
SECTION 13580 MICROPROCESSORS PART 1 GENERAL 1.01 DESCRIPTION A. The contractor shall furnish a MicroLok II Vital Microprocessor Based Interlocking System (VMIS) and Non-Vital Based Interlocking Systems
More informationStarrett-Bytewise Measurement Systems Profile In-Line Pipe Diameter Measurement System Technical Proposal May 8, 2014
Overview Profile360 TM is an in-line, real-time measurement system for continuously monitoring OD, OOR, and circumference for round pipe and profiles. Profile360 can be installed in two locations, in-line
More informationUsing Operator Interfaces to Optimize Performance of Industrial Wireless Networks
Using Operator Interfaces to Optimize Performance of Industrial Wireless Networks Jim Ralston, Wireless Sales Engineer ProSoft Technology, August 2007 Abstract The performance of wireless networks can
More informationProducts Solutions Services. Functional Safety. How to determine a Safety integrity Level (SIL 1,2 or 3)
Products Solutions Services Functional Safety How to determine a Safety integrity Level (SIL 1,2 or 3) Slide 1 Functional Safety Facts Agenda of the next 45 min SIL 1,2 or 3 Let s apply IEC61511 SIS, whats
More informationStarrett-Bytewise Measurement Systems Profile In-Line Pipe Diameter Measurement System Technical Proposal May 8, 2014
Overview Profile360 TM is an in-line, real-time measurement system for continuously monitoring OD, OOR, and circumference for round pipe and profiles. Profile360 can be installed in two locations, in-line
More informationInstallation Instructions
Installation Instructions (Cat. No. 71-A1B, -A2B, -A3B, -A3B1, -A4B Series B) Because of the variety of uses for the products described in this publication, those responsible for the application and use
More informationMedium-Voltage Drive SINAMICS SM150. Type 6SL3845. Tests carried out on drives This documentation pertains to SM150 wassergekühlt G20 F03 F72 F79 F76
Tests carried out on drives This documentation pertains to SM150 wassergekühlt G20 F03 F72 F79 F76 Reference Manual Medium-Voltage Drive SINAMICS SM150 Type 6SL3845 Edition 02/2019 www.siemens.com/drives
More informationProline Prowirl 72, 73
Functional Safety Manual Vortex flow measuring system with 4 20 ma output signal Application Monitoring of maximum and/or minimum flow in systems which are required to comply with particular safety system
More informationHow flowmeters perform self-verification
How flowmeters perform self-verification Here s how modern flowmeters verify their own measurement performance By Nathan Hedrick, Endress+Hauser, USA Process manufacturing and other industrial facilities
More informationIndustrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example
Introduction 1 Application example 2 Industrial Controls Motor management and control devices SIMOCODE pro - Application examples Application Manual Example circuits control functions 3 Further application
More informationPROCESS CONTROL SYSTEMS LAP 4 Loop Controllers. Notes
PROCESS CONTROL SYSTEMS LAP 4 Loop Controllers Notes 1) Loop Controllers a) Two categories of loop controllers (1) Pneumatic controllers (a) Use air inputs/outputs to sense the process variable and send
More informationProcess Safety Management Suite
Process Safety Management Suite The Process Safety Management Suite (PSMS) is a range of software packages designed to assist in the lifecycle management of Satety Instrumented Systems. Allowing for a
More informationSafe and Fault Tolerant Controllers
Safe and Fault Tolerant Controllers SIMATIC Safety Integrated for Process Automation Wiring and Evaluation Architectures for Failsafe Digital Input (F-DI)- and Output-Modules (F-DO) of ET 200M Functional
More informationIndustrial controls SIRIUS Innovations Star-Delta (Wye-Delta) Combination Assembly and Wiring Application description June 2010
Cover Sheet Industrial controls SIRIUS Innovations Star-Delta (Wye-Delta) Combination Assembly and Wiring Application description June 2010 Applications & Tools Answers for industry. Industry Automation
More information1791 Analog Block I/O Input/Output Modules User Manual
User Manual Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary
More information5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor.
5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL 33309 3211 Fruitland Ave Los Angeles, CA 90058 UM-600 6-Channel Monitor Version 2 Installation and Operation Manual Rev. G P/N145F-12990 PCO 00007462 (c)
More informationTHE SMARTPLANT INSTRUMENTATION VENDOR SUPPLY CHAIN
THE SMARTPLANT INSTRUMENTATION VENDOR SUPPLY CHAIN FLUOR SmartPlant Implementation Team By: John Dressel Copyright 2018 Fluor Corporation all rights reserved SPI Vendor Supply Chain Introduction The SPI
More informationR147 WIRELESS ANTI-TWO-BLOCK INDICATOR
55M0147GSE00 Rev. E R147 WIRELESS ANTI-TWO-BLOCK INDICATOR Installation and Operation Manual Ref: VH sept 2012 Copyright 2012 RaycoWylie Systems All Rights Reserved. The purpose of this manual is to
More informationHART. Actuator Control. Redefining Flow Control
HART Actuator Control Contents Section Page Introduction 3 Actuator Control 4 HART Module 5 HART Network 5 Point-To-Point Network 6 Multi-Drop Network 6 Commands 7 Control Features 8-9 Device Description
More informationMinutes to Meltdown: EMP and the Threat to Nuclear Power
DISCLAIMER: The opinions, conclusions, and recommendations expressed or implied within are solely those of the author(s) and do not necessarily represent the views of the Department of Defense, or any
More informationSAFETY INSTRUMENTED SYSTEM (SIS) FOR PROCESS OPERATION BASED ON REAL- TIME MONITORING. by Cen Kelvin Nan
SAFETY INSTRUMENTED SYSTEM (SIS) FOR PROCESS OPERATION BASED ON REAL- TIME MONITORING by Cen Kelvin Nan Background Research Contributions Proposed Methodology Case Study Conclusions Future Works Acknowledgements
More informationVariable Area Flowmeters Installation Instructions G Series and M Series
Variable Area Flowmeters Installation Instructions G Series and M Series Safety Definitions Potential danger to life or of serious injuries. Potential for personal injury from electrical shock. Safety
More informationProject Execution Best Practices
Project Execution Best Practices Tips & Tricks based on lessons learnt 1 Successful Implementation & Improved Operation Temporary vs. Permanent Communication Ad-hoc Communication: Handheld field communicators
More informationHART Temperature Transmitter for up to SIL 2 applications
HART Temperature Transmitter for up to SIL 2 applications Inor Process AB 05/2014 86B520S001 R1.3 1 Introduction... 3 1.1 Field of application... 3 1.2 User benefits... 3 1.3 Manufacturer s safety instructions...
More informationCommissioning Benefits
Freedom to Choose. Power to Integrate. Commissioning Benefits Andreas Agostin MTL Instruments On behalf of Fieldbus Foundation Marketing Committee Freedom to Choose. Power to Integrate. Commissioning Benefits?
More informationFront End Engineering and Design (FEED)
Front End Engineering and Design (FEED) Freedom to Choose. Power to Integrate. Yeo Hwee Khoen Honeywell On behalf of Fieldbus Foundation 1 Freedom to Choose. Power to Integrate. FEED Benefits Applying
More informationSPI Protocol Interface Module Cat. No SPI Concepts Manual
Concepts Manual Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary
More informationISO INTERNATIONAL STANDARD. Safety of machinery Safety-related parts of control systems Part 1: General principles for design
INTERNATIONAL STANDARD ISO 13849-1 Second edition 2006-11-01 Safety of machinery Safety-related parts of control systems Part 1: General principles for design Sécurité des machines Parties des systèmes
More informationSE Engineering, PC strives to be a leader in the power system engineering field by providing our customers with the highest level of quality,
SE Engineering, PC strives to be a leader in the power system engineering field by providing our customers with the highest level of quality, integrity, and innovation. Our mission is to offer the safest,
More informationIs This What the Future Will Look Like?
Is This What the Future Will Look Like? Implementing fault tolerant system architectures with AUTOSAR basic software Highly automated driving adds new requirements to existing safety concepts. It is no
More informationFailure Modes, Effects and Diagnostic Analysis
Failure Modes, Effects and Diagnostic Analysis Project: 9106 HART Transparent Repeater and 9107 HART Transparent Driver Customer: PR electronics A/S Rønde Denmark Contract No.: PR electronics 06/03-19
More informationARC VIEW. Leveraging New Automation Approaches Across the Plant Lifecycle. Keywords. Summary. By Larry O Brien
ARC VIEW JUNE 22, 2017 Leveraging New Automation Approaches Across the Plant Lifecycle By Larry O Brien Keywords Operational Excellence, Cloud, Virtualization, Operations Management, Field Commissioning,
More informationDistributed Control Systems in New Nuclear Power Plants
IYNC 2008 Interlaken, Switzerland, 20 26 September 2008 Paper No. 235 ABSTRACT Distributed Control Systems in New Nuclear Power Plants Author Joseph Doerfler Westinghouse Electric Company 4350 Northern
More informationInform IT Information Management Tenore. SCADA Extension ABB
ABB Introduction Thanks to the power of its Information Platform, and to the versatility of its architecture, Tenore can easily be employed as a Supervisory and Control Station in a SCADA system for the
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61508-6 First edition 2000-04 Functional safety of electrical/electronic/ programmable electronic safety-related systems Part 6: Guidelines on the application of IEC 61508-2
More informationSmart Commissioning. White Paper February 2018
Smart Commissioning Smart Commissioning is a technology-enabled approach for streamlining the commissioning of field instrumentation connected to a DeltaV Distributed Control System (DCS) or Safety Instrumented
More informationSITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3
Overview Safety notes 1 SITOP power supply Manual Description, device design, dimension drawing 2 Mounting/removal 3 Mounting position, mounting clearances 4 Installation 5 Technical data 6 Safety, approvals,
More informationPAST PRESENT & FUTURE TRENDS IN INDUSTRIAL AUTOMATION
PAST PRESENT & FUTURE TRENDS IN INDUSTRIAL AUTOMATION Dr. J. PRAKASH ASSISTANT PROFESSOR IN INSTRUMENTATION ENGINEERING Madras Institute of Technology ANNA UNIVERSITY DATA ACQUISITION SYSTEM (DAS) SUPERVISORY
More informationPart 2: Basic concepts and terminology
Part 2: Basic concepts and terminology Course: Dependable Computer Systems 2012, Stefan Poledna, All rights reserved part 2, page 1 Def.: Dependability (Verlässlichkeit) is defined as the trustworthiness
More informationSiemens Digitalized Production Cell Boosts Auto Parts Manufacturing by 20% siemens.com/global/en/home/products/automation
Siemens Digitalized Production Cell Boosts Auto Parts Manufacturing by 20% siemens.com/global/en/home/products/automation Overview Increases in order size and quantity led Wisconsin-based auto parts manufacturer
More informationSystem 800xA Safety AC 800M High Integrity Safety Manual
System 800xA Safety AC 800M High Integrity Safety Manual System Version 5.1 Power and productivity for a better world TM System 800xA Safety AC 800M High Integrity Safety Manual System Version 5.1 NOTICE
More informationIEC Basics. Presented by. Bill Lydon, Director PLCopen North America Automation Industry Consultant
IEC 61131 Basics Presented by Bill Lydon, Director PLCopen North America Automation Industry Consultant blydon@plcopen-na.org Page 1 Why standard software? Standardization Improves Productivity Quality
More informationEquipment Strategy For High Voltage Circuit Breakers
Current version: 23/05/2018 EXTERNAL USE Page 1 of 7 Table of contents 1. Introduction... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 References... 3 1.4 Defined terms... 3 1.5 Monitoring and compliance... 3
More informationDIGITAL CONTROLLER Multi-Loop. smar
DIGITAL CONTROLLER Multi-Loop smar INTRODUCTION The CD600Plus is a powerful stand-alone single-station process controller. It is capable of simultaneously controlling up to 4 loops with up to 8 PIDs and
More informationGE Intelligent Platforms
GE Intelligent Platforms PAC8000 Hybrid Workbench Powerful software for advanced control strategies PAC8000 Strategy Builder for process control applications IEC 61131-3 software for logic control applications
More informationApplication Guideline for Muting Two-Hand Control Devices in a Control Reliable Circuit
Application Guideline for Muting Two-Hand Control Devices in a Control Reliable Circuit DA-2103 Revision 1.0 October, 2003 Index 1 Abstract 2 Goals Common References, Safety Circuits, and Performance
More informationDeckblatt. APL Operator Guide SIMATIC PCS 7. Application description June Applikationen & Tools. Answers for industry.
Deckblatt SIMATIC PCS 7 Application description June 2011 Applikationen & Tools Answers for industry. Industry Automation and Drive Technologies Service & Support Portal This article is taken from the
More informationA COMBINED PLC AND CPU APPROACH TO MULTIPROCESSOR CONTROL
GA-A22196 A COMBINED PLC AND CPU APPROACH TO MULTIPROCESSOR CONTROL by J.J. HARRIS, J.D. BROESCH, and R.M. COON DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United
More informationIndustrial IT System 800xA Operations. Reducing time to decision and action. Overview. Features and Benefits
Industrial IT System 800xA Operations Overview Features and Benefits Personalized workplaces for focused information access Workplace layouts are adjusted and optimized to users preferences and needs with
More informationIssues in Programming Language Design for Embedded RT Systems
CSE 237B Fall 2009 Issues in Programming Language Design for Embedded RT Systems Reliability and Fault Tolerance Exceptions and Exception Handling Rajesh Gupta University of California, San Diego ES Characteristics
More informationWhat s New in DeltaV Version 14
What s New in DeltaV Version 14 DeltaV Live Modern, built-for-purpose operations experience DeltaV v14.3 introduces DeltaV Live, Emerson s new, modern, built-for-purpose operations experience, designed
More informationSmart Commissioning. White Paper January 2019
is a technology-enabled approach for streamlining the commissioning of field instrumentation connected to a DeltaV Distributed Control System (DCS) or Safety Instrumented System (SIS). It reduces the effort
More informationExecutive summary. by Michel Bonnet, Maximilien Laforge, and Jean-Baptiste Samuel
998-2095-02-21-14AR0 by Michel Bonnet, Maximilien Laforge, and Jean-Baptiste Samuel Executive summary Improper integration of Intelligent Electronic Devices (IED) into medium / high voltage electrical
More informationCape Software Inc. Houston TX
The Virtual Process Overview and Applications Cape Software Inc. Houston TX Corporate Overview Founded in 1996 HQs located in Houston Products: VP Link : Flexible Process Simulation Drivers and database
More informationSummary. Business Value
Summary Feedwater control systems Tricon Triple Modular Redundant (TMR) Digital System for Feedwater Control and Safety Application in Nuclear Power Plants are critical to the safe and efficient operation
More informationSoftware Quality. Chapter What is Quality?
Chapter 1 Software Quality 1.1 What is Quality? The purpose of software quality analysis, or software quality engineering, is to produce acceptable products at acceptable cost, where cost includes calendar
More informationAdvanced Test Equipment Rentals ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Rosemount 2088 and 2090 Appendix B Rosemount 275 HART Communicator Overview....................................... page
More informationFailure Diagnosis and Prognosis for Automotive Systems. Tom Fuhrman General Motors R&D IFIP Workshop June 25-27, 2010
Failure Diagnosis and Prognosis for Automotive Systems Tom Fuhrman General Motors R&D IFIP Workshop June 25-27, 2010 Automotive Challenges and Goals Driver Challenges Goals Energy Rising cost of petroleum
More informationSensoTrans DMS P 32200
ProLine Interface Technology Strain Gauge Transmitters The transmitters for strain gauge full bridges in a 6 mm housing with infrared interface and SIL approval. The Task In many different industrial applications
More informationHART Modem for USB. Features. Description. Datasheet HmUSB-01 December Ideal for configurations, data acquisition and digital control.
HmUSB Description The Computer Modem HmUSB is a complete communication path for a HART network. It will enable personal computers to read and or configure data within HART devices. The computer USB connector
More informationApplication on Control Technology
Application on Control Technology Programming example in Ladder Logic (SSL) to determine a battery fault Warranty, liability and support Note The application examples are not binding and do not claim to
More informationMobrey Hydratect 2462
Mobrey Hydratect 2462 Functional Safety Manual Functional Safety Manual Functional Safety Manual Table of Contents Contents 1Section 1: Introduction 1.1 Scope and purpose of the safety manual..................................
More informationLowering Lifecycle Costs
Lowering Lifecycle Costs with Intelligent Motor Control Centers Standards Certification Education & Training Publishing Conferences & Exhibits Speakers: Presented and Authored by Jeff M. Miller, PE, ENV
More information