POWERLINC PROGRAMMING MANUAL v1.2a

Size: px
Start display at page:

Download "POWERLINC PROGRAMMING MANUAL v1.2a"

Transcription

1 INTRODUCTION The PowerLinc from SmartHome will provide 12V 300mA DC and two-way power-line communication to any PowerLinc compatible OEM 1 unit. The PowerLinc can also be used as a direct TW523 replacement for two-way power-line communication only. Known PowerLinc compatible devices are listed in appendix A. USAGE Plug the PowerLinc box into any standard 120V 60Hz power outlet. Plug the other end of the PowerLinc into the OEM unit that will be communicating with the power-line. Outlet PowerLinc OEM Unit CAUTION the PowerLinc is not designed nor approved for use on power-lines that operate on non-120v/60hz cycles. Attempting to use the PowerLinc on non-approved power-lines may have hazardous consequences. Also, do not plug the PowerLinc into a telephone jack or telephone equipment. Doing so may result in equipment failure. The PowerLinc is designed for power-line communication, not telephone communication. CONNECTOR SPECIFICATIONS ADDITIONAL RESOURCES The X10 TW523 technical manual is available online at pdf. The PowerLinc programming manual is available online at Please check for documentation upgrades. The PowerLinc is available for purchase at 1 Original Equipment Manufacturer 1

2 APPENDIX A Compatibility Chart POWERLINC FEATURE DEVICE MANUFACTURER POWER PLC RS232 HomeVision Custom Solutions HouseLinc SmartHome One for All Command Center Universal Electronics Time Commander Plus JDS TouchLinc SmartHome 8 CH X10 Relay Control RCS 16 CH X10 Relay Control RCS X10 Thermostat RCS 2

3 APPENDIX B RS232 Protocol for standard X10 transmission (Please refer to Appendix D for extended raw data transmission) RS232 communication parameters to the PowerLinc are 8 data bits, no parity, 1 stop bit, 9600 baud. This must precede all commands: 1. Send 0x02 to the PowerLinc. 2. The PowerLinc will respond with ACK (0x06) if ready, NAK (0x15) if not ready. 3. The ACK will be followed by a carriage return (0x0D). The NAK isn t followed with a carriage return. After an ACK (0x06) and carriage return (0x0D) is received, the PowerLinc is ready to accept a command. To send an X10 house code, unit code, and function code, send the following hexadecimal bytes to the PowerLinc: 0x63 [Send X10 Command] [Refer to Appendix C for house code hex or ASCII byte to send to PowerLinc] [Refer to Appendix C for unit code hex or ASCII byte to send to PowerLinc] [Refer to Appendix C for function code hex or ASCII byte to send to PowerLinc] [Refer to Appendix E for Repeat Count to send to PowerLinc] Additional notes: To leave out the function code, substitute a 0x00 in its place. For example, to send A1 only: 0x63 0x46 0x4C 0x00 0x41 To leave out the unit code, place the function code in the unit code s place, then place a 0x00 in the function code s place. For example, to send AON only: 0x63 0x46 0x45 0x00 0x41 Example communication for A1 AON 0x02 [start command ] 0x06 [ACK ] 0x63 [send X10 command ] 0x46 [house code A ] 0x4C [unit code 1 ] 0x45 [function code On ] 0x41 [repeat command once ] 0x58 [transmission received ] 0x46 [house code A ] 0x4C [unit code 1 ] 0x31 [sent once ] 0x58 [transmission received ] 0x46 [house code A ] 0x45 [function code On ] 0x31 [sent once ] The symbol indicates communication to the PowerLinc, and indicates from the PowerLinc to the OEM unit. 3

4 APPENDIX C - PowerLinc X10 Code Chart X10 Code X10 Hex Code Hex byte or Ascii byte to send to PowerLinc A F B 0E 4E N C B D 0A 4A J E A F I G E H 0D 4D M I G J 0F 4F O K C L 0B 4B K M 00 N H O D P 0C 4C L 1 0C 4C L 2 1C 5C \ D T B R 7 0A 4A J 8 1A 5A Z 9 0E 4E N 10 1E 5E ^ F V P H X All Units Off A All Lights On C On E Off G Dim I Bright 0B 4B K All Lights Off 0D 4D M Extended Code 0F 4F O Hail Request Q Pre-Set Dim High W Pre-Set Dim Low U Extended Data (analog) Y Status = on 1B 5B [ Status = off 1D 5D ] Status Request 1F 5F _ 4

5 APPENDIX D - RS232 Protocol for extended raw transmission (Please refer to Appendix B for standard X10 transmission) RECEIVE The PowerLinc recognizes extended code data over the power-line. Upon seeing an X10 function code of extended code or extended data, the PowerLinc will echo back a lower case ASCII e to signify that there is extended data on the power-line, then it will echo back all output on the power-line in hexadecimal format until it sees a three zero-cycle gap (as per X10 specification). Example 1: The PowerLinc sees the following bits on the power-line: SC HC P FC XD XD ZCG SC = Start Code HC P = House Code P FC XD = Function Code Extended Data XD = Extended Data ZCD = Three zero-cycle gaps After seeing the extended data on the power-line, the PowerLinc first echoes back a lower case ASCII e to signify that there is extended data on the power-line. Then, according to the binary data above, the PowerLinc would echo the following hexadecimal bytes: E A 5 A 5 A A [SC ][ HC P ] [ FC XD ][ XD + part of ZCG ] Resulting with a total ASCII output string of eêz[ø, which corresponds to the following hexadecimal bytes: 65 EA 5A 5A A8. Not all of the three zero-cycles are echoed back. Example 2: The Stanley X10 Door Position Transmitter sends the following hex data on the power-line when the TEST button is pressed: E6 96 A9 A9 55 5A 9B 9A A6 A A 60 Which the PowerLinc echoes back as: eæ YUZ šz euj` (quotes not included). Note that the actual raw data starts after the first character e, since the e is simply to signify that the rest of the data is extended data. 5

6 Transmit: The PowerLinc permits the user to place any data out onto the power-line. To send data onto the power-line, send hex-code 80, followed by a byte count (in hex) of the data to be placed onto the power-line, followed by the data to be placed on the power-line. The data to be placed on the power-line should be complimented, per X10 specification, and terminated by six 0 s, to indicate a three zero-cycle gap. While this is the recommendation, the PowerLinc will allow the user to place any data on the power-line. Example: The symbol indicates communication to the PowerLinc, and indicates from PowerLinc to the unit. 0x02 [start command ] 0x06 [ACK ] 0x80 [send extended data ] 0x05 [byte count ] 0xEA [Start code + House code ] 0x96 [House code + Function code] 0xAA [Function code + Extended data] 0x6A [Extended data ] 0x98 [Extended data + gap ] 0x00 [Gap ] The hexadecimal data is translated into the following binary data on the power-line: E A 9 A 9 A 6 A [SC ] [ HC ] [ FC ][ XD ][ ZCG ] SC = Start Code: three 1 s followed by a 0. X10 protocol dictates that all X10 transmissions should start with this start code. HC = House Code: expanded house code For example, house code A which is normally 0110 (0x06) becomes When the house code is expanded out, each bit is complimented. Another example: house code M ( 0000 or 0x00) would be expanded out to FC = Function Code: expanded function/unit code Similarly to the house code, the function code also needs to be expanded out. In the above example, the expanded function code is This condenses to 11001, or 0x19 ; which is the X10 hexadecimal code for extended data. Another example: function code ON ( 0101 or 0x05) would be expanded out to XD = Extended Data The extended data in the above example is The extended data is completely arbitrary, but is recommended to conform to the X10 specification of complimenting every bit. Six 0 s will signify an X10 End-of-transmission. ZCG = Three zero-cycle gap X10 protocol dictates that all X10 transmissions should be terminated by a three zero-cycle gap. The six 0 s on the end satisfy this requirement. 6

7 APPENDIX E - PowerLinc Repeat Code Chart Repeat Count (decimal) ASCII Byte Hex Byte 1 A 0x41 2 B 0x42 3 C 0x43 4 D 0x44 5 E 0x45 6 F 0x46 7 G 0x47 8 H 0x48 9 I 0x49 10 J 0x4A 11 K 0x4B 12 L 0x4C 13 M 0x4D 14 N 0x4E 15 O 0x4F 7

RS-232 Control of the Advantage EQ281/8, EQ282/8 and Advantage SMS200

RS-232 Control of the Advantage EQ281/8, EQ282/8 and Advantage SMS200 RS-232 Control of the Advantage EQ281/8, EQ282/8 and Advantage SMS200 Biamp Systems, 14130 N.W. Science Park, Portland, Oregon 97229 U.S.A. (503) 641-7287 an affiliate of Rauland-Borg Corp. Introduction

More information

The RS-485 user manual for B800 series communication

The RS-485 user manual for B800 series communication The user manual of B800 Series Rs-485 The RS-485 user manual for B800 series RS-232 inbuilt inside the main board of B800 series frequency inverter, we can effect RS-485 through fitting board externally.

More information

Computer Control of the Advantage DRC 4+4

Computer Control of the Advantage DRC 4+4 Computer Control of the Advantage DRC 4+4 Biamp Systems, 14130 N.W. Science Park, Portland, Oregon 97229 U.S.A. (503) 641-7287 an affiliate of Rauland-Borg Corp. Introduction This document contains technical

More information

Custom Installation Notes IP/Serial programming interface and IR remote control commands for the SA10/SA20 integrated amplifier

Custom Installation Notes IP/Serial programming interface and IR remote control commands for the SA10/SA20 integrated amplifier Custom Installation Notes IP/Serial programming interface and IR remote control commands for the SA10/SA20 integrated amplifier INTEGRATED AMPLIFIER PHONES AUX MUTE AUX PHONO STB PVR AV BD CD SAT POWER

More information

TABLE OF CONTENTS 2/10

TABLE OF CONTENTS 2/10 TABLE OF CONTENTS TABLE OF CONTENTS...2 1. OVERVIEW...3 1.1 RS485/RS232 SIGNALS...3 1.2 X10 SIGNALS...3 2. PROTOCOL...4 2.1 QUICK REFERENCE...4 2.1.1 PACKET DESCRIPTION...4 2.1.2 RS485/RS232 SIGNAL SENT

More information

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam UDP411 BD Player

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam UDP411 BD Player 23425 Custom Installation Notes: Serial programming interface and IR remote commands for Arcam UDP411 BD Player POWER / STANDBY ULTRA HIGH PERFORMANCE 24-BIT DAC ULTRA 1 Contents Introduction...3 Conventions...3

More information

RS485 MODBUS Module 8AO

RS485 MODBUS Module 8AO Version 1.3 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam D33 DAC

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam D33 DAC 23425 Custom Installation Notes: Serial programming interface and IR remote commands for Arcam D33 DAC ULTRA HIGH PRECISION DIGITAL TO ANALOGUE CONVERTER D33 44.1 48 88.2 1 2 96 176.4 192 1 OPTICAL 2 1

More information

HMC1022 Digital Compass

HMC1022 Digital Compass Key Features Based on Honeywell s HMC1022 solid-state magnetic sensor Choice of 2 Interface Options (UART/I2C) Standard Pin Headers come soldered Plug and Play Module SPECIFICATIONs Angular Measuring Range

More information

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for Version 1.0 16.05.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam BDP100/300 BD Players

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam BDP100/300 BD Players 23425 Custom Installation Notes: Serial programming interface and IR remote commands for Arcam BDP100/300 BD Players POWER / STANDBY ULTRA HIGH PERFORMANCE 24-BIT DAC 1 Contents Introduction...3 Conventions...3

More information

RS-232 Control of the Advantage DRI

RS-232 Control of the Advantage DRI RS-232 Control of the Advantage DRI Biamp Systems, 14130 N.W. Science Park, Portland, Oregon 97229 U.S.A. (503) 641-7287 an affiliate of Rauland-Borg Corp. Introduction This document contains technical

More information

LynX-10 Legacy Protocol Specification Version 1.01

LynX-10 Legacy Protocol Specification Version 1.01 LynX-10 Legacy Protocol Specification Version 1.01 Marrick Limited LynX-10 TM Legacy Protocol Specification Manual revision 1.01 Marrick Limited, Incorporated P.O. Box 950940 Lake Mary, FL 32795 (407)

More information

TORRIX RS485. Technical Documentation. with MODBUS Protocol. Edition: Version: 2 Art. no.:

TORRIX RS485. Technical Documentation. with MODBUS Protocol. Edition: Version: 2 Art. no.: Technical Documentation TORRIX RS485 with MODBUS Protocol Edition: 2016-05 Version: 2 Art. no.: 350187 FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg Tel.: +49 / 40 / 39 82 07 0 Fax: +49 / 40 / 390

More information

1. Implemented CM11 protocol

1. Implemented CM11 protocol 1. Implemented CM11 protocol 1.1. Housecodes and Device Codes. The housecodes and device codes range from A to P and 1 to 16 respectively although they do not follow a binary sequence. The encoding format

More information

PRE32 RS232 protocol v1.21 Tomas Andersson

PRE32 RS232 protocol v1.21 Tomas Andersson PRE32 RS232 protocol 2014-11-07 v1.21 Tomas Andersson Description This document describes the RS232 protocol used to control the PRE32 device. Command structure Commands are sent to the device using the

More information

Elotech Standard Protocol. for Single R8200 SC

Elotech Standard Protocol. for Single R8200 SC Elotech Standard Protocol interface description / network protocol for Single R8200 SC ELOTECH Industrieelektronik GmbH Verbindungsstraße 27 D - 40723 HILDEN FON +49 2103 / 255 97 0 FAX +49 2103 / 255

More information

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam T32 Tuner

Custom Installation Notes: Serial programming interface and IR remote commands for Arcam T32 Tuner 23425 Custom Installation Notes: Serial programming interface and IR remote commands for Arcam T32 Tuner Contents Introduction...3 Conventions...3 Serial Cable Specification...3 transfer format...3 Command

More information

RS485 MODBUS Module 16I-M

RS485 MODBUS Module 16I-M Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

Control Characters used in DirectNET

Control Characters used in DirectNET Control Characters used in DirectNET ENQ (0x05) Enquiry to start communications ACK (0x06) Acknowledge (data received and no errors NAK (0x15) Negative Acknowledge (data received but there were errors)

More information

DEBUGGING SERIAL COMMUNICATIONS WITH OTHER DEVICES

DEBUGGING SERIAL COMMUNICATIONS WITH OTHER DEVICES DEBUGGING SERIAL COMMUNICATIONS WITH OTHER DEVICES NOTE: This application note is intended for users connecting an external device to a HomeVision serial port. It may be helpful to users connecting to

More information

JUMO Quantrol LC100/LC200/LC300

JUMO Quantrol LC100/LC200/LC300 JUMO Quantrol LC100/LC200/LC300 Universal PID Controller Series B 702030.2.0 Interface Description Modbus 2013-05-27/00600589 Content 1 Introduction................................................ 5 1.1

More information

TORRIX RS485. Technical Documentation. with MODBUS Protocol. Edition: Version: 3 Art. no.:

TORRIX RS485. Technical Documentation. with MODBUS Protocol. Edition: Version: 3 Art. no.: Technical Documentation TORRIX RS485 with MODBUS Protocol Edition: 2017-03 Version: 3 Art. no.: 350187 FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg Tel.: +49 / 40 / 39 82 07 0 Fax: +49 / 40 / 390

More information

ambient XC RS232 Control Command Specification

ambient XC RS232 Control Command Specification ambient XC RS232 Control Command Specification Table of Contents ambient XC RS232 Control Command Specification...1 Goal...2 COM port properties...2 Initialisation of RS232 communication...2 Determine

More information

JMY504M User's Manual

JMY504M User's Manual JMY504M User's Manual (Revision 3.42) Jinmuyu Electronics Co. LTD 2011/6/28 Please read this manual carefully before using. If any problem, please mail to: Jinmuyu@vip.sina.com Contents 1 Product introduction...

More information

RS485 MODBUS Module 8I8O

RS485 MODBUS Module 8I8O Expansion Module 8 digital inputs, 8 digital outputs Version 2.2 12/01/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the

More information

RoHS. CO 2, Temperature & Humidity Transmitter Applications

RoHS. CO 2, Temperature & Humidity Transmitter Applications NDIR CO 2 Dual sensor Needless calibration on long-term use Can measure over 95% RH condition Applicable to humid storage, mushroom farm and floricultural industry Communication Method RS-485 (Standard)

More information

C628 Enhanced JPEG Module. User Manual

C628 Enhanced JPEG Module. User Manual C628 Enhanced JPEG User Manual v1.1 Release Note: 1. May 2, 2006 official released v1.0 2. Dec 27, 2006 revise electrical characteristics Table of Contents Part I - Hardware Overview 1 Features.. 1 Specifications

More information

Optris CT/ CTlaser/ CTvideo communication interface

Optris CT/ CTlaser/ CTvideo communication interface Optris CT/ CTlaser/ CTvideo communication interface Serial interface parameters Protocol Baud rate: 9600 115200, set by user (factory default: 115200) Data bits: 8 Parity: ne Stop bits: 1 Flow control:

More information

Xanura Isolated RS232 interface module CTX15 MBO BA. OEM module for serial communication with Xanura

Xanura Isolated RS232 interface module CTX15 MBO BA. OEM module for serial communication with Xanura Xanura Isolated RS232 interface module CTX15 MBO 1991 519-401 BA OEM module for serial communication with Xanura Xanura CTX15 Table of contents 1 Overview 3 1.1 RS485/RS232 signals 3 1.2 Xanura signals

More information

B Interface description 12.01/

B Interface description 12.01/ B 95.3530.2 Interface description 12.01/00340396 Contents 1 Introduction 1.1 Preface... 3 1.2 Typographical conventions... 4 1.2.1 Warning signs... 4 1.2.2 Note signs... 4 1.2.3 Presentation... 4 2 Protocol

More information

Input Channels: 4 differential or four single-ended. Address / Baud rate / range configurable by the user

Input Channels: 4 differential or four single-ended. Address / Baud rate / range configurable by the user DAM-Series User Manual Amazing Electronic (HK) Limited User s Manual Overview: DAM module is a new generation data acquisition and control system based on modular embedded systems. Adopting standard DIN35

More information

Ethereal Exercise 2 (Part A): Link Control Protocol

Ethereal Exercise 2 (Part A): Link Control Protocol Course: Semester: ELE437 Ethereal Exercise 2 (Part A): Link Control Protocol Introduction In this exercise some details at the data link layer will be examined. In particular, the Link Control Protocol

More information

RS 485 Mini Modbus 1AO

RS 485 Mini Modbus 1AO RS 485 Mini Modbus 1AO Version 1.0 14/08/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained

More information

Modbus Remote Communication Protocol for REM 54_. Technical Description

Modbus Remote Communication Protocol for REM 54_. Technical Description Modbus Remote Communication Protocol for REM 54_ 1MRS 750781-MUM Issued: 08.03.2002 Version: A/18.06.2002 Checked: ML Approved: AF Remote Communication Protocol for REM 54_ Modbus We reserve the right

More information

DataVU 5 - Interface Manual Modbus

DataVU 5 - Interface Manual Modbus DataVU 5 - Interface Manual Modbus 59482 Contents 1 Introduction 5 1.1 Preface... 5 1.2 Typographical conventions... 6 1.2.1 Warning signs... 6 1.2.2 Note signs... 6 1.2.3 Representation modes... 6 2

More information

$GDSWLYH0LFUR6\VWHPV

$GDSWLYH0LFUR6\VWHPV $GDSWLYH0LFUR6\VWHPV $/3+$,QGXVWULDO3URWRFRO Revision 3.2 9711-8814A Alpha Industrial Protocol-V3.2.doc Page 1 of 58 Table of Contents 1.0 Revision History... 6 2.0 Introduction... 7 3.0 Control-T and

More information

DataVU 5 - Interface Manual Modbus

DataVU 5 - Interface Manual Modbus DataVU 5 - Interface Manual Modbus 59482 Contents 1 Introduction 5 1.1 Preface... 5 1.2 Typographical conventions... 6 1.2.1 Warning signs... 6 1.2.2 Note signs... 6 1.2.3 Representation modes... 6 2

More information

Getting Started with your D3000M Series Module

Getting Started with your D3000M Series Module Getting Started with your D3000M Series Module This document contains step-by-step instructions to quickly connect and communicate with your D3000M modules. The modules require a one-time configuration

More information

SC1602LCPro-YG ( Yellow Green Backlight ) SC1602LCPro-B ( Blue Backlight ) Large Character Size ( 4.88x9.66 mm )

SC1602LCPro-YG ( Yellow Green Backlight ) SC1602LCPro-B ( Blue Backlight ) Large Character Size ( 4.88x9.66 mm ) SC1602LCPro-YG ( Yellow Green Backlight ) SC1602LCPro-B ( Blue Backlight ) Large Character Size ( 4.88x9.66 mm ) Features 16 x 2 Large Characters RS485 Serial Interface Programmable Device Address Programmable

More information

Number Representations

Number Representations Simple Arithmetic [Arithm Notes] Number representations Signed numbers Sign-magnitude, ones and twos complement Arithmetic Addition, subtraction, negation, overflow MIPS instructions Logic operations MIPS

More information

SC1602LC 16x2 Large Characters RS232 LCD Module. User s Manual. Large Viewing Area 99mm x 24mm. Large Character Size. 4.84mm x 9.66mm.

SC1602LC 16x2 Large Characters RS232 LCD Module. User s Manual. Large Viewing Area 99mm x 24mm. Large Character Size. 4.84mm x 9.66mm. Large Viewing Area 99mm x 24mm Large Character Size 4.84mm x 9.66mm Features 16x2 Large Characters LCD RS232 Interface Simple Serial Command Wide Range Voltage Operation ( 9-15V ) 8 User s Defined Characters

More information

Application Note BDLxxxx RS232 SERIAL INTERFACE COMMUNICATION PROTOCOL (SICP V1.82)

Application Note BDLxxxx RS232 SERIAL INTERFACE COMMUNICATION PROTOCOL (SICP V1.82) Application Note BDLxxxx RS232 SERIAL INTERFACE COMMUNICATION PROTOCOL (SICP V1.82) Table of Contents 1. INTRODUCTION... 1 1.1 PURPOSE... 1 1.2 DEFINITIONS, ABBREVIATIONS AND ACRONYMS... 1 2. COMMAND PACKET

More information

Tag Interface. 1. Introduction. 2. Control Modes. Olufemi Omojola, Rich Fletcher Physics and Media Group MIT Media Lab, January 2000

Tag Interface. 1. Introduction. 2. Control Modes. Olufemi Omojola, Rich Fletcher Physics and Media Group MIT Media Lab, January 2000 Tag Interface Olufemi Omojola, Rich Fletcher Physics and Media Group MIT Media Lab, January 2000 1. Introduction The concept of a common control model for all tag readers is targeted towards a single interface

More information

2a. Codes and number systems (continued) How to get the binary representation of an integer: special case of application of the inverse Horner scheme

2a. Codes and number systems (continued) How to get the binary representation of an integer: special case of application of the inverse Horner scheme 2a. Codes and number systems (continued) How to get the binary representation of an integer: special case of application of the inverse Horner scheme repeated (integer) division by two. Example: What is

More information

Planar Simplicity Series

Planar Simplicity Series Planar Simplicity Series RS232 PROTOCOL Document 020-1285-00 1. INTRODUCTION 1.1 Purpose The purpose of this document is to explain in detail the commands and steps that can be used to control a Planar

More information

Instruction and Operation Manual

Instruction and Operation Manual SEC IR PC LINK Instruction and Operation Manual Sensor Electronics Corporation 5500 Lincoln Drive Minneapolis, Minnesota 55436 USA (952) 938-9486 Fax (952) 938-9617 email sensor@minn.net or www.sensorelectronics.com

More information

RS232 User Guide. Planar Simplicity Series 4K Displays SL4364K SL5564K SL6564K SL7564K SL8664K. Simplicity Series 4K Displays User Guide A

RS232 User Guide. Planar Simplicity Series 4K Displays SL4364K SL5564K SL6564K SL7564K SL8664K. Simplicity Series 4K Displays User Guide A RS232 User Guide Planar Simplicity Series 4K Displays SL4364K SL5564K SL6564K SL7564K SL8664K 020-1344-00A Page 1 Copyright March 2018 by Leyard Optoelectronics Co., Ltd. and Planar Systems, Inc. All rights

More information

JUMO ctron 04/08/16. Compact controller with timer and ramp function. B Interface Description Modbus /

JUMO ctron 04/08/16. Compact controller with timer and ramp function. B Interface Description Modbus / JUMO ctron 04/08/16 Compact controller with timer and ramp function 702071 702072 702074 B 70.2070.2.0 Interface Description Modbus 2008-08-11/00492538 Contents 1 Introduction 5 1.1 Preface... 5 1.2 Typographical

More information

VS-LC101/ VS-LC102 RS-232 command set

VS-LC101/ VS-LC102 RS-232 command set VS-LC101/ VS-LC102 RS-232 command set No Issue Date Description Apply Firmware 1 2015/09/14 First version. v3.1.5.28 2 2018/04/27 1. RS-232 command(control Protocol) will respond ACK 2. RC pass-through

More information

Custom Installation Notes: Serial programming interface for Arcam A/V processors & receivers

Custom Installation Notes: Serial programming interface for Arcam A/V processors & receivers Custom Installation Notes: Serial programming interface for Arcam A/V processors & receivers Models covered: AVP700, AVR250, AVR300, AVR350 Contents Applicability... 2 Controlling Arcam A/V processors

More information

Motors I Automation I Energy I Transmission & Distribution I Coatings. Modbus RTU CFW701. User s Manual

Motors I Automation I Energy I Transmission & Distribution I Coatings. Modbus RTU CFW701. User s Manual Motors I Automation I Energy I Transmission & Distribution I Coatings Modbus RTU CFW701 User s Manual Modbus RTU User s Manual Series: CFW701 Language: English Document Number: 10001538593 / 00 Publication

More information

SF10 SF10. Features: The SF10 laser altimeter is ideal for automated landings and precision hovering.

SF10 SF10. Features: The SF10 laser altimeter is ideal for automated landings and precision hovering. The is a compact, lightweight laser altimeter for above-groundlevel altitude measurement from small fixed wing or multi-rotor craft. The laser altimeter is ideal for automated landings and precision hovering.

More information

JMY505G User's Manual

JMY505G User's Manual JMY505G User's Manual (Revision 3.42) Jinmuyu Electronics Co. LTD 2011/6/28 Please read this manual carefully before using. If any problem, please mail to: jinmuyu@vip.sina.com Contents 1 Product introduction...

More information

J2 LCM Customer Display. Manual

J2 LCM Customer Display. Manual J2 LCM Customer Display Manual July 2012 Contents LCM Customer Display... 3 Overview... 3 Customer Display Configureation... 4 Port Settings... 4 CD Settings... 5 Emulation Mode... 5 Character Sets...

More information

SAFETY PRECAUTIONS. Throughout this manual we use the following two illustrations to make you aware of safety considerations:

SAFETY PRECAUTIONS. Throughout this manual we use the following two illustrations to make you aware of safety considerations: Thank you for purchasing Marathon Drive (MD100P) RS485 Option Card! SAFETY PRECAUTIONS Always follow safety precautions to prevent accidents and potential hazards from occurring. In this manual, safety

More information

SC2004MBS 20x4 Characters MODBUS RTU Slave LCD

SC2004MBS 20x4 Characters MODBUS RTU Slave LCD SC004MBS 0x4 Characters MODBUS RTU Slave SC004MBS is a MODBUS slave device that receives data from a Master MODBUS device and display them on the panel. The is 0 x 4 characters in size and each character

More information

TECH TIP. Tritex Modbus Protocol Specification

TECH TIP. Tritex Modbus Protocol Specification Tritex Modbus Protocol Specification Introduction This document describes Tritex s implementation of the MODBUS communication protocol used for transferring data between a serial host and an Exlar drive.

More information

OPTRIS CT/CTL communication interface

OPTRIS CT/CTL communication interface OPTRIS CT/CTL communication interface Serial interface parameters Protocol Baud rate: 9600 115200, set by user (factory default: 9600) Data bits: 8 Parity: ne Stop bits: 1 Flow control: off The protocol

More information

RS 232 Interface. RS 232 is the Serial interface on the PC. Three major wires for the Serial interface: Transmit Pin 2 Receive Pin 3

RS 232 Interface. RS 232 is the Serial interface on the PC. Three major wires for the Serial interface: Transmit Pin 2 Receive Pin 3 RS 232 Interface RS 232 is the Serial interface on the PC Three major wires for the Serial interface: Transmit Pin 2 Receive Pin 3 Note: SR510 switches pins 2,3 internally HP Func. Gen. Requires a null

More information

N700E Inverter RS485 Interface Instruction Manual

N700E Inverter RS485 Interface Instruction Manual Technical Support Document for Inverter Doc. No. Model TSD-N700E-COM-001E(00) All N700E model Rev. Date June, 2009 N700E Inverter RS485 Interface Instruction Manual Contents 1. RS485 function...1 1.1 function...1

More information

Sample F4T 32-bit Modbus RTU Packet

Sample F4T 32-bit Modbus RTU Packet Sent to F4T - Read (32-bit) Slot 1, Analog Input 1 value 00000011 0x03 3 Function Code - Read Holding Registers 01101011 0x6B 107 Read Starting at register High Byte (Analog Input 1 value in slot 1 is

More information

SDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for

SDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for Version 1.2 20.01.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

D730. Remote Display Installation Manual

D730. Remote Display Installation Manual D730 Remote Display Installation Manual Copyright All Rights Reserved. No part of this document may be copied, reproduced, republished, uploaded, posted, transmitted, distributed, stored in or introduced

More information

Chaper 1: E10+ PLCs Host-Link Command Format

Chaper 1: E10+ PLCs Host-Link Command Format Chaper 1: E10+ PLCs Host-Link While an E10+ programmable logic controller is running, a host computer can send commands in the form of ASCII strings to the controller to read or write to the inputs, outputs,

More information

MODEL CIO-EN PROGRAMMING GUIDE MODBUS/TCP, MODBUS/RTU I/O MODULE. Revision A1 Rapid City, SD, USA, 09/2008

MODEL CIO-EN PROGRAMMING GUIDE MODBUS/TCP, MODBUS/RTU I/O MODULE. Revision A1 Rapid City, SD, USA, 09/2008 PROGRAMMING GUIDE MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE Revision A1 Rapid City, SD, USA, 09/2008 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848 (605) 348-5580 fax (605)

More information

11 Serial Communications

11 Serial Communications 11.1 COMMUNICATIONS PACKAGES There are a number of communication packages that can be used with the Quantum III to facilitate setup, record parameter data, view internal activity on a soft-scope and permit

More information

Protocol of SOJI Fuel level sensor FJ-RS232/FJ-RS485 Version 1.0.2

Protocol of SOJI Fuel level sensor FJ-RS232/FJ-RS485 Version 1.0.2 Protocol of SOJI Fuel level sensor FJRS232/FJRS485 Version 1.0.2 Document preparion Full Name Title Prepared by Nguyen Duy Tan Engineer Approved by Quang Nguyen Project manager Date 1 October 2016 1 October

More information

SRF02 Ultrasonic range finder Technical Specification

SRF02 Ultrasonic range finder Technical Specification SRF02 Ultrasonic range finder Technical Specification I2C Mode For Serial mode click here I2C Communication To use the SRF02 in I2C mode, make sure nothing is connected to the mode pin, it must be left

More information

CRX Card Reader Generic Interface - Programmer s Guide

CRX Card Reader Generic Interface - Programmer s Guide Card Reader Generic Interface - Programmer s Guide Table of Contents Limited Warranty...3 Disclaimer...3 Section 1: General Information Introduction...4 Section 2; Numeric and Data Formats...4 Section

More information

JUMO di 308. Digital Indicator. B Interface Description Modbus 12.07/

JUMO di 308. Digital Indicator. B Interface Description Modbus 12.07/ JUMO di 308 Digital Indicator B 70.1550.2.0 Interface Description Modbus 12.07/00485372 Contents 1 Introduction 5 1.1 Preface... 5 1.2 Typographical conventions... 6 1.2.1 Warning signs... 6 1.2.2 Note

More information

OBDII J1708/J1587 Simulator

OBDII J1708/J1587 Simulator 1 Features: Support the total 8 protocols., Customer can choose any 2 protocols or any 5 protocols or all 8 protocols in different cost 1. ISO14230-4 (KWP2000) Fast Init 2. ISO14230-4 (KWP2000) Baud 5

More information

DirectNET Host. Communications Programs. In This Chapter...

DirectNET Host. Communications Programs. In This Chapter... Communications Programs In This Chapter.... Why do you need a communications program? Modes of Operation Protocol Components Controlling the Communications Initiating the Request Acknowledging the Request

More information

RS485 MODBUS Module 8I8RO

RS485 MODBUS Module 8I8RO Expansion Module 8 digital inputs, 8 relay outputs Version 1.0 3.12.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device.

More information

Flex Series User Guide

Flex Series User Guide User Programmable Current 4..20mA Digital RS485 Dual & Single Axis Up to 360º 2016 Flex Series User Guide Sensor Installation, Wiring, Flexware App Instructions Page 1 of 33 Page 2 of 33 Table of Contents

More information

Subject Server vs Display Protocol Using UART Report Number Author Project Version 3.00 Remarks This document is for Internal Use.

Subject Server vs Display Protocol Using UART Report Number Author Project Version 3.00 Remarks This document is for Internal Use. Commandes API RS232 Subject Server vs Display Protocol Using UART Report Number Author Project Version 300 Remarks This document is for Internal Use Abstract This document describes Server vs Display Serial

More information

Appendix) Specifications of Monitor & Control Rev. 4.0 July 13, 2016

Appendix) Specifications of Monitor & Control Rev. 4.0 July 13, 2016 Specifications of Monitor & Control July 13, 2016 1. Interface Specifications 1-1. FSK Communication M&C (1) Physical Interface IF Connector: N-type or F-type, female Combine with IF signal and 10MHz Reference

More information

UniOP VT100 Terminal Emulation - Ver. 3.16

UniOP VT100 Terminal Emulation - Ver. 3.16 UniOP VT100 Terminal Emulation - Ver. 3.16 This tech note describes the operation of the VT100 emulation software on UniOP. This document is a short reference for VT100 Terminal Emulation software. It

More information

Chapter 2 Number System

Chapter 2 Number System Chapter 2 Number System Embedded Systems with ARM Cortext-M Updated: Tuesday, January 16, 2018 What you should know.. Before coming to this class Decimal Binary Octal Hex 0 0000 00 0x0 1 0001 01 0x1 2

More information

CTT MODBUS-RTU COMMUNICATION PROTOCOL TEMPERATURE MONITOR DEVICE

CTT MODBUS-RTU COMMUNICATION PROTOCOL TEMPERATURE MONITOR DEVICE INSTRUCTION MANUAL IM149-U v0.92 CTT MODBUS-RTU COMMUNICATION PROTOCOL TEMPERATURE MONITOR DEVICE Firmware version: v3.0 or higher MODBUS PROTOCOL Modbus is a master-slave communication protocol able to

More information

Modbus RTU CFW100. User s Manual. Phone: Fax: Web: -

Modbus RTU CFW100. User s Manual. Phone: Fax: Web:  - Modbus RTU CFW100 User s Manual Modbus RTU User s Manual Series: CFW100 Language: English Document Number: 10002909455 / 00 Publication Date: 06/2014 CONTENTS CONTENTS... 3 ABOUT THIS MANUAL... 5 ABBREVIATIONS

More information

Max. Shock Acc. :147 m/s{15g} Time: 11ms Pulse Wave: Half Since Wave Pulse (3 times in X,Y,Z) IEC IEC Fast Transient Power Module

Max. Shock Acc. :147 m/s{15g} Time: 11ms Pulse Wave: Half Since Wave Pulse (3 times in X,Y,Z) IEC IEC Fast Transient Power Module FEATURES Multi Drop Configuration of up to 32 units Baud Rates Ranging from 300 to 38,400bps 1:1 /1:N / N:M (RS-422) Communication is Supported Supports Full-Duplex (RS-422) and Half-Duplex (RS-485) Built-in

More information

ModBus Communication protocol. The ModBus protocol is an industrial communications and distributed control system

ModBus Communication protocol. The ModBus protocol is an industrial communications and distributed control system ModBus Communication protocol ModBus Communication Standards The ModBus protocol is an industrial communications and distributed control system to integrate PLCs, computers, terminals, and other monitoring,

More information

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual

Rev Carbon Dioxide (CO2) Gas Sensor. TG100 User Manual Rev. 2.93 TG100 User Manual The TG100 measuring carbon dioxide (chemical formula CO2) is a NDIR (Non-Dispersive Infrared) gas sensor. As it is contactless, it has high accuracy and longer life than sensors

More information

5016 Installation and Communication RS485

5016 Installation and Communication RS485 5016 Installation and Communication RS485 5016 Loadcell connection Module RS485 full-duplex point-to-point communication Software: LB.150611.2v1 Doc. no.: 5016 InstAndComm 150611-1v0e-eng.doc Date: 2015-11-28

More information

VISY-Command. Technical Documentation. with Modbus Protocol. Edition: Version: 1 Art. no.:

VISY-Command. Technical Documentation. with Modbus Protocol. Edition: Version: 1 Art. no.: Technical Documentation with Modbus Procol Edition: 2017-04 Version: 1 Art. no.: 350253 FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg Germany Tel.: +49 / 40 / 39 82 07-0 Fax: +49 / 40 / 390 63 39

More information

BNI IOL K023 BNI IOL K023. User s Guide

BNI IOL K023 BNI IOL K023. User s Guide BNI IOL-712-000-K023 BNI IOL-714-000-K023 User s Guide 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations 2 1.3.2 Actions 2 1.3.3

More information

CSCI 2212: Intermediate Programming / C Chapter 15

CSCI 2212: Intermediate Programming / C Chapter 15 ... /34 CSCI 222: Intermediate Programming / C Chapter 5 Alice E. Fischer October 9 and 2, 25 ... 2/34 Outline Integer Representations Binary Integers Integer Types Bit Operations Applying Bit Operations

More information

INTELLIS. Modbus Direct Network Monitor

INTELLIS. Modbus Direct Network Monitor INTELLIS Modbus Direct Network Monitor System Installation and Operation Manual Phone: (201) 794-7650 Fax: (201)794-0913 Chapter 1 Modbus Protocol Revision History Revision 1.0 30 April, 2002 Initial Version

More information

Data Communication Protocol Host Computer to FAS-A

Data Communication Protocol Host Computer to FAS-A Data Communication Protocol Host Computer to FAS-A Overview This section codifies the communication protocol between an FAS-A and a host computer. Utilizing these protocols the host computer can 1) acquire

More information

Venstar Thermostat Adapter

Venstar Thermostat Adapter Developer Venstar Thermostat Adapter v001 Developer Venstar Thermostat Adapter Version 001 May 23, 2013 Revision History Rev Date Comments 001 05/23/13 Initial Release Page 1 of 13 Table of Contents 1

More information

KCD-HP. KCD-HP200x, 300X. [Figures] Top : 1% Sensor probe Bottom left : 10% / 20% Sensor probe Bottom right : Holding bracket(optional) Measurement

KCD-HP. KCD-HP200x, 300X. [Figures] Top : 1% Sensor probe Bottom left : 10% / 20% Sensor probe Bottom right : Holding bracket(optional) Measurement Our CO2 gas sensors get a small deviation unlike NDIR Single type. So they keep long term stability. KCD-HP100x Excellent stability and accuracy - through testing and calibration with sophisticated process

More information

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide BNI IOL302000Z026 BNI IOL302S01Z026 User s Guide 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations 2 1.3.2 Actions 2 1.3.3 Syntax

More information

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide BNI IOL302000Z026 BNI IOL302S01Z026 User s Guide Balluff Network Interface / IOLink BNI IOL302xxxZ026 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions

More information

Analyzing the command string for switch to input #

Analyzing the command string for switch to input # Marshall VSW-2200 Switcher Control Protocol Firmware Version: 3.3 Document edited 8-22-2016 (legacy command structures have been removed from this document) Serial Port (over USB) Setting: Baud rate :

More information

Modbus Protocol For FTS/FTM 3x&8x

Modbus Protocol For FTS/FTM 3x&8x [ 公司地址 ] Modbus Protocol For FTS/FTM 3x&8x V3.0 Introduction This document describes the protocol detail of Modbus for FTSXX Hardware interface - The interface on the sensor is RS-485. - Hardware named

More information

Optidrive VTC Modbus RTU Register Map

Optidrive VTC Modbus RTU Register Map Application Note AN-VTC- 39 Optidrive VTC Modbus RTU Register Map Author: Ning Xu, Invertek Drives Ltd Revision: 2.21 6 September 2006 General This document details the Modbus RTU memory mapping implemented

More information

Home Automation, Inc. Omni-Link. Serial Protocol Description

Home Automation, Inc. Omni-Link. Serial Protocol Description Home Automation, Inc. Omni-Link Serial Protocol Description This document contains the intellectual property of Home Automation, Inc. (HAI). HAI authorizes the use of this information for the sole purpose

More information

User Manual version 1.04 TLM8 COMMUNICATION PROTOCOLS

User Manual version 1.04 TLM8 COMMUNICATION PROTOCOLS User Manual version 1.04 TLM8 COMMUNICATION PROTOCOLS Load Cell Systems reserves the right to change specifications without notice. 2018 Web: https://loadcellsys.com Email: sales@loadcellsys.com Phone:

More information

ENGLISH ENGLISH ENGLISH ENGLISH

ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH ENGLISH User Manual version 1.04 TLM8 COMMUNICATION PROTOCOLS Protocols for instruments CE-M APPROVED EN45501:2015-2014/31/UE-OIML R76:2006 KEY TO SYMBOLS Below are the symbols

More information