SmartStack Deployment Guide with Cisco UCS Mini and Nimble CS300

Size: px
Start display at page:

Download "SmartStack Deployment Guide with Cisco UCS Mini and Nimble CS300"

Transcription

1 SmartStack Deployment Guide with Cisco UCS Mini and Nimble CS300 Last Updated: November 24,

2 About Cisco Validated Designs The CVD program consists of systems and solutions designed, tested, and documented to facilitate faster, more reliable, and more predictable customer deployments. For more information visit ALL DESIGNS, SPECIFICATIONS, STATEMENTS, INFORMATION, AND RECOMMENDATIONS (COLLECTIVELY, "DESIGNS") IN THIS MANUAL ARE PRESENTED "AS IS," WITH ALL FAULTS. CISCO AND ITS SUPPLIERS DISCLAIM ALL WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE. IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THE DESIGNS, EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE DESIGNS ARE SUBJECT TO CHANGE WITHOUT NOTICE. USERS ARE SOLELY RESPONSIBLE FOR THEIR APPLICATION OF THE DESIGNS. THE DESIGNS DO NOT CONSTITUTE THE TECHNICAL OR OTHER PROFESSIONAL ADVICE OF CISCO, ITS SUPPLIERS OR PARTNERS. USERS SHOULD CONSULT THEIR OWN TECHNICAL ADVISORS BEFORE IMPLEMENTING THE DESIGNS. RESULTS MAY VARY DEPENDING ON FACTORS NOT TESTED BY CISCO. CCDE, CCENT, Cisco Eos, Cisco Lumin, Cisco Nexus, Cisco StadiumVision, Cisco TelePresence, Cisco WebEx, the Cisco logo, DCE, and Welcome to the Human Network are trademarks; Changing the Way We Work, Live, Play, and Learn and Cisco Store are service marks; and Access Registrar, Aironet, AsyncOS, Bringing the Meeting To You, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, CCVP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity, Collaboration Without Limitation, EtherFast, EtherSwitch, Event Center, Fast Step, Follow Me Browsing, FormShare, GigaDrive, HomeLink, Internet Quotient, IOS, iphone, iquick Study, IronPort, the IronPort logo, LightStream, Linksys, MediaTone, MeetingPlace, MeetingPlace Chime Sound, MGX, Networkers, Networking Academy, Network Registrar, PCNow, PIX, PowerPanels, ProConnect, ScriptShare, SenderBase, SMARTnet, Spectrum Expert, StackWise, The Fastest Way to Increase Your Internet Quotient, TransPath, WebEx, and the WebEx logo are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries. All other trademarks mentioned in this document or website are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0809R) 2015 Cisco Systems, Inc. All rights reserved. 2

3 Table of Contents About Cisco Validated Designs... 2 Executive Summary... 6 Solution Overview... 7 Introduction... 7 Audience... 7 Solution Design... 8 Compute... 8 Virtualization... 9 Storage Networking SmartStack Topology Low-level Design Validated Hardware and Software Cisco Nexus Initial Configuration and Setup Cisco Nexus Global Configuration Cisco Nexus VPC Configuration Cisco Nexus Configuration to Cisco UCS Mini Fabric Interconnect Storage Configuration Nimble Setup Manager Initialize the Nimble Storage Array Configure the Nimble OS using the GUI Nimble Management Tools: InfoSight Nimble Management Tools: vcenter Plugin Server Configuration Initial Setup and Configuration Log in to Cisco UCS Manager (UCS Manager) Synchronize Cisco UCS Mini to NTP Configure Ports Connected to Switching Infrastructure Configure PortChannels on Uplink Ports Configure Ports Connected to Storage Array Server Configuration Workflow: vnic Template Creation Create VLANs: Management VLAN on Uplink Ports to Cisco Nexus 9000 Series Switches Create VLANs: Application Data VLANs on Uplink Ports to Cisco Nexus 9000 Series Switches Create VLANs: Appliance Port VLANs to Nimble Storage Create LAN Pools: Mac Address Pools Create LAN Policies: QoS and Jumbo Frame

4 Create LAN Policies: Network Control Policy for Uplinks to Cisco Nexus Switches Create LAN Policies: Network Control Policy for Storage vnics Create LAN Policies: vnic Templates for Management Traffic Create LAN Policies: vnic Templates for Uplink Port Traffic Create LAN Policies: vnic Templates for Appliance Port Traffic Server Configuration Workflow: Appliance Port Policies Create LAN Policies: Network Control Policy for Appliance Port Create LAN Policies: Flow Control Policy for Appliance Port Apply Policies to Appliance Port Server Configuration Workflow: Server Policies Create Server Policies: Power Control Policy Create Server Policies: Server Pool Qualification Policy Create Server Policies: BIOS Policy Create Server Policies: iscsi Boot Adapter Policy Create Server Policies: Local Disk Configuration Policy Create Server Policies: Boot Policy Create Server Policies: Maintenance Policy Create Server Polices: Host Firmware Package Policy Server Configuration Workflow: Server, LAN and SAN Pools Create Server Pools: UUID Suffix Pool Create LAN Pools: IP Pools Create SAN Pools: iscsi IQN Pools Server Configuration Workflow: Service Profile Template Creation Create Service Profile Template Service Profile Template Wizard: Networking Service Profile Template Wizard: Storage Service Profile Template Wizard: Boot Policy Service Profile Template Wizard: Maintenance Policy Service Profile Template Wizard: Server Assignment Service Profile Template Wizard: Operational Policies Cisco UCS Configuration Backup Deploying a New Server Generate a Service Profile for the Host from the Service Profile Template Associate the Service Profile with the Host iscsi SAN Boot Setup - Create Initiator Group for the ESXi host iscsi SAN Boot Setup - Create Boot Volume for the host iscsi SAN Boot Setup - Configure the iscsi Target on the ESXi Host ESXi 6.0 SAN Boot Installation Post-ESXi Install-Setup

5 Deploying Infrastructure Services VMware vcenter 6.0 U Install and Setup Microsoft Windows Server 2012 R Install and Setup VMware vcenter Server Appliance (VCSA) Install the Client Integration Plug-In Install vcenter Server Appliance Log in to vsphere Web Client vcenter Server Appliance Setup Install the Client Integration Plugin vcenter Server Appliance Setup Join Active Directory Domain vcenter Server Appliance Setup ESXi Dump Collector Setup vcenter Center with a Datacenter, Cluster, DRS and HA Select Virtual Machine Swap File Location Add Node to Cluster Add the AD Account to the Administrator Group About the Authors Acknowledgements

6 Executive Summary Executive Summary SmartStack is an integrated infrastructure solution, designed and validated to meet the needs of mid-sized enterprises or departmental or remote deployments within larger environments. SmartStack infrastructure platform combines Cisco UCS Mini and Nimble CS300 array into a single, highly redundant and flexible architecture that can support different hypervisors, use cases and workloads. SmartStack platform management is enabled through Cisco UCS Manager integrated into the Cisco UCS Mini, VMware vcenter, Nimble Array Management GUI and Nimble InfoSight, a cloud based management solution. SmartStack is a Cisco Validated Design (CVD). CVDs are systems and solutions that have been designed, tested, and documented to facilitate and accelerate customer deployments. Documentation for this CVD includes the following documents: SmartStack Design Guide SmartStack Deployment Guide This document serves as the SmartStack Deployment Guide. SmartStack Design Guide associated with this deployment guide can be found at: 6

7 Solution Overview Solution Overview Introduction This document outlines the deployment procedures for implementing a SmartStack infrastructure solution based on VMware vsphere 6.0, Cisco UCS Mini, Nimble CS300 and Cisco Nexus switches. Audience The intended audience for this document includes, but is not limited to, sales engineers, field consultants, professional services, IT managers, partner engineering, and customers who want to deploy the core SmartStack architecture with Cisco UCS Mini and Nimble CS300. 7

8 Solution Design The SmartStack architecture based on Cisco UCS Mini and directly attached Nimble CS300 storage array provide an optimal solution for mid-sized Enterprises and departmental or remote branch deployments within larger Enterprises. SmartStack solution integrates Cisco UCS Mini and Nimble CS300 storage array to deliver compute, storage and 10 Gigabit Ethernet (10GbE) networking in an easy-to-deploy, compact platform. The stateless server provisioning and management capabilities of Cisco UCS Manager combined with Nimble make SmartStack easier to deploy and manage. For more details on the SmartStack architecture, please refer to the SmartStack Design Guide: Compute The compute platform in this design is a Cisco UCS Mini with redundant Cisco UCS 6324 Fabric Interconnects (FI) providing 10 Gigabit Ethernet (GbE) connectivity to both network and storage infrastructure. The two Fabric Interconnects are deployed in a cluster for redundancy and provide two fabric planes (Fabric A, Fabric B) that are completely independent of each other from a data plane perspective. In the event of a failure or if only one was deployed, the fabric can be fully operational with one FI. The Fabric Interconnects in the SmartStack design are deployed in End-host Ethernet switching mode. Ethernet switching mode determines how the fabric interconnects behave as switching devices between the servers and the network. End-host mode is the default and generally recommended mode of operation. In this mode, the fabric interconnects appear to the upstream LAN devices as end hosts with multiple adapters and do not run Spanning Tree. The Cisco Nexus switch ports that connect to the Cisco Fabric Interconnects are therefore deployed as spanning tree edge ports. The ports on the Cisco UCS 6324 are unified ports that can support either Ethernet or Fibre Channel traffic based by changing the port mode. This storage access in this architecture uses iscsi so all ports are deployed in Ethernet mode. Ethernet ports on the fabric interconnects are unconfigured by default and must be explicitly configured as a specific type, which determines Uplink ports for connecting to Cisco Nexus 9300 series switches and external LAN network Appliance ports for connecting to directly attached iscsi-based Nimble CS300 array Server ports for connecting to external Cisco UCS C-series rack mount servers Cisco UCS Manager (Cisco UCS Manager) is used to provision and manage Cisco UCS Mini and its subcomponents (chassis, FI, blade and rack mount servers). Cisco UCS Manager runs on the Fabric Interconnects. A key feature of Cisco UCS Manager are Service Profile Templates that enable the abstraction of policies, pools and other aspects of a server configuration and consolidate it in the form of a template. The configuration in a service profile template includes: Server Identity (For example: UUID Pool, Mac Address Pool, IP Pools) 8

9 Server Policies (For example: BIOS Policy, Host Firmware Policy, Boot Policy) LAN Configuration (For example: VLAN, QoS, Jumbo Frames) Storage Configuration (For example: IQN pool) The template, once created, can be used to generate a service profile that configure and deploy individual servers or groups of servers. A service profile defines the server and its storage and networking characteristics. Service Profile Templates reduce deployment time, increases operational agility, and provides general ease of deployment. Service Profile Templates are used in this SmartStack design to rapidly configure and deploy multiple servers with minimal modification. Cisco UCS B-Series and C-Series servers provide the compute resources in the SmartStack design. Several models of these servers are supported see the Cisco UCS Mini release notes for a complete list. The compute design comprises of an infrastructure layer and an application layer with compute resources allocated to both. The infrastructure layer consists of common infrastructure services that are necessary to deploy, operate and manage the entire deployment. These include, but not limited to, Active Directory (AD), Dynamic Name Resolution Server (DNS) and VMware vcenter and were deployed for validating the SmartStack architecture. The application layer consists of any virtualized application, hosted on SmartStack compute, which the business needs to fulfill its business functions. Depending on the size of the business, the application layer in a customer deployment could be extensive, with multiple levels of hierarchy and redundancy for supporting a large set of applications. The converged infrastructure to support the application layer may require multiple units of SmartStack to be deployed, with each unit scaled to 12 hosts (maximum supported as of this writing). SmartStack solution was validated using virtual machines (VM) running Microsoft Windows 2008R2 and IOMeter tool to generate load. Virtualization The common infrastructure services and the associated virtual machines (VM) are part of a dedicated infrastructure cluster (SS-Mgmt) running VMware HA. A separate cluster (SS-VM-Cluster1), also running VMware HA, hosts the application VMs. VMware virtual switches (vswitch) are used to provide layer 2 connectivity between the virtual machines. Cisco Nexus 1000V switches or VMware distributed virtual switches could also be used, particularly in larger deployments. Cisco UCS servers were deployed with Cisco UCS 1340 VIC network adapter. At the server level, each Cisco VIC presents multiple vpcie devices to ESXi node which vsphere identifies as vmnics. ESXi is unaware that these NICs are virtual adapters. The virtual NICs (vnic) are configured during the Service Profile Template creation and deployed on each server when the service profile is created and associated with the server. In the SmartStack design, the following virtual NICs are used. One vnic for iscsi traffic on Fabric A (iscsi-a) One vnic for iscsi traffic on Fabric B (iscsi-b) Two vnics for in-band management and vmotion (MGMT-A, MGMT-B) Two vnics for Application VM traffic (vnic-a, vnic-b) The connectivity within each ESXi server and the vnics presented to ESXi in the form of vmnics are shown in the figure below. 9

10 Figure 1 VMware ESXI Network Storage The Nimble array in this design provides iscsi based block storage. iscsi is also used to SAN boot the ESXi hosts on the Cisco UCS Mini. Storage controllers on the Nimble CS300 are connected to Appliance ports on each Cisco UCS Fabric Interconnect. This design uses two physically diverse switch fabrics as well as logically distinct iscsi data VLANs (iscsi-a-san, iscsi-b-san). Virtual PortChannels are not used on the links between Cisco UCS Mini and Nimble. VLAN Trunking is also not necessary as Appliance ports carry traffic bound for one specific iscsi VLAN to either Fabric A or Fabric B. Jumbo frames are also enabled on these links. The Service Profile template used in this design has both primary and secondary iscsi SAN boot configurations to allow boot to occur even when one path or FI is down. In addition, host based iscsi multipathing with two distinct IP domains and iscsi targets are also used to ensure access to storage at all times. The Nimble Storage CS300 dual controller design provides either 10Gbps Ethernet or 16Gbps Fibre Channel connectivity on multiple links. In this CVD, Nimble CS300 is configured for 10Gbps Ethernet connectivity. Each storage controller can have from 2 to 4 10Gbps connections per controller. The total bandwidth capacity is the aggregate of bandwidth of all 10Gbps ports on a single controller. In the event of a controller 10

11 failover, the same amount of network bandwidth is still available. The CS300 controller is also equipped with 2 x 6Gb SAS expander connections for additional shelf options. The Nimble controllers operate in Active / Standby mode. In this design, the redundant links to each controller delivers 20Gbps of storage bandwidth to the current Active controller. If one of the links on the Active controller fails, the Standby controller will become the Active controller to ensure that 20Gbps of bandwidth is always available. The CS300 array can scale performance by upgrading compute for greater throughput. It can be scale capacity by adding expansion shelves. It can also scale flash to accommodate a wide variety of application of working sets. Any of these options is combined to the specific need of the workload. The configuration tested in this design is a CS300 equipped with 24TB of storage and 3.2TB of flash capacity as shown below. Figure 2 Nimble Storage Array Configuration To optimize and model the required performance, the storage array and virtual machines will be remotely. This will provide insight into I/O and capacity usage, trend analysis for capacity planning and expansion, as well as pro-active ticketing and notification when any issues occur. Networking Networking infrastructure provides network connectivity to applications hosted on Cisco UCS Mini. A pair of Cisco Nexus 9372 PX switches, deployed in NX-OS standalone mode were used in this design. Redundant 10Gbps links from each Cisco Nexus switch is connected to the Uplink ports on each FI to provide an aggregate bandwidth of 20Gbps on each uplink. The design uses Virtual PortChannel (vpc) for the network allowing multiple parallel paths between nodes with load balancing that result in increased bandwidth and redundancy. VLAN Trunking is enabled on these links as multiple application data VLANs, management and vmotion traffic will need to traverse these links. Jumbo Frames are also enabled on the uplinks to support vmotion. 11

12 SmartStack Topology The figure below shows the SmartStack architecture. Figure 3 SmartStack with Cisco UCS Mini and Direct Attached Nimble CS300 Low-level Design The first two ports on each FI are connected to a pair of Cisco Nexus 9372 PX switches using 10GbE links as shown in Figure 3. These Ethernet ports on the fabric interconnects are configured as Uplink ports using Cisco UCS Manager. The uplinks ports are then enabled for Link aggregation using PortChannels with uplink ports on FI-A in one PortChannel and the FI-B uplink ports on another. The uplinks ports are connected to different Cisco Nexus switches and configured to be part of a virtual PortChannel (vpc) on the Cisco Nexus switches. vpc11 and vpc12 shown in Figure 3 are PortChannels that connect Cisco Nexus A and Cisco Nexus B to FI-A and FI-B respectively. The Cisco Nexus vpc feature allows a third device to aggregate links going to different Cisco Nexus switches. As a result, the uplink ports appear as a regular PortChannel to Cisco UCS Min as shown below. Link aggregation on the uplinks between Cisco UCS Mini and Cisco Nexus switches follow Cisco recommended best practices. The detailed deployment procedures are covered in an upcoming section of this document. Multiple VLANs need to traverse the uplink ports and uplink ports are automatically configured as IEEE 802.1Q trunks for all VLANs defined on the fabric interconnect. VLANs for management, vmotion and 12

13 application traffic are defined on the fabric interconnects and enabled on the uplinks. The VLANs used in validating the SmartStack design are summarized in the table below. Table 1 Uplink VLANs between Cisco UCS Mini and Cisco Nexus VLAN Type (VLAN Name) VLAN ID (Used in SmartStack Validation) Description Native VLAN (default) 2 Untagged VLAN Traffic are forwarded on this VLAN In-Band Management (MGMT) 12 VLAN used for in-band management, including ESXi hosts and Infrastructure VMs vmotion 12 VLAN used by ESXi for moving VMs between hosts. vmotion uses management VLAN VM Application Traffic (Data-v900, Data-v901) 900, 901 VLAN used by Application Data Traffic The next two-10gbe ports on each Cisco UCS 6324 FI are used to directly connect to Nimble CS300 storage array. The ports on the FI connecting to the array were configured as Appliance ports. Appliance ports on each Fabric Interconnect are enabled for one iscsi VLAN as shown in the table below. Table 2 iscsi VLANs between Cisco UCS Mini and Nimble VLAN Type (VLAN Name) VLAN ID (Used in SmartStack Validation) Description iscsi Path A (iscsi-a-san) 3010 VLAN used for iscsi traffic on Fabric A. This VLAN exists only on Fabric A. iscsi Path B (iscsi-b-san) 3020 VLAN used for iscsi traffic on Fabric A. This VLAN exists only on Fabric B. The iscsi Qualified Name (IQN) Block, IP Blocks, MAC block and iscsi Discovery IP used in validation for the two independent iscsi Paths are shown in the table below. Table 3 iscsi Deployment Information Mac Address Pool for vnic iscsi-a on FI-A (Block of 128) Mac Address Pool for vnic iscsi-b on FI-B (Block of 128) 00:25:B5:AA:AA:00-00:25:B5:AA:AA:7F 00:25:B5:BB:BB:00-00:25:B5:BB:BB:7F IP Pool for iscsi-a on FI-A IP Pool for iscsi-b on FI-B iscsi IQN Name Suffix iqn.com.ucs-blade 13

14 iscsi IQN Block (Block of 16) esx-blade:1 esx-blade:16 iscsi Discovery IP for iscsi-a on FI-A (TCP Port 3260) iscsi Discovery IP for iscsi-b on FI-A (TCP Port 3260) Validated Hardware and Software The table below is a summary of all the components used for validating the SmartStack design. Table 4 Infrastructure Components and Software Revisions Infrastructure Stack Component Software Revision Details Compute Cisco UCS Mini N/A Blade Server Chassis Cisco UCS B200 M (c) Server/Host on Cisco UCS Mini Cisco UCS FI (c) Embedded Fabric Interconnect on Cisco UCS Mini Cisco UCS Manager 3.0.2(c) Embedded Management Cisco enic Driver Ethernet driver for Cisco VIC Network Cisco Nexus 9372 PX 6.1(2)I3(4a) Optional Storage Nimble CS300 Array Build: opt Nimble NCM for ESXi Build: Virtualization VMware vsphere 6.0 Build: VMware vcenter Server Appliance U1 Build: Microsoft SQL Server 2012 RP1 VMware vcenter Database Cisco Nexus 9000 This section provides detailed procedures for deploying a Cisco Nexus 9k switch in a SmartStack environment. Note that Cisco Nexus 9000 is an optional component of the SmartStack Infrastructure Solution. Skip to the next section if a different type of switch or an existing switching infrastructure is used with this SmartStack deployment. 14

15 Initial Configuration and Setup This section outlines the initial configuration necessary for bringing up a new Cisco Nexus Cisco Nexus A To set up the initial configuration for the first Cisco Nexus switch complete the following steps: 1. Connect to the serial/console port of the switch Enter the configuration method: console Abort Auto Provisioning and continue with normal setup? (yes/no[n]: y ---- System Admin Account Setup ---- Do you want to enforce secure password standard (yes/no[y]: Enter the password for "admin": Confirm the password for "admin": ---- Basic System Configuration Dialog VDC: This setup utility will guide you through the basic configuration of the system. Setup configures only enough connectivity for management of the system. Please register Cisco Nexus9000 Family devices promptly with your supplier. Failure to register may affect response times for initial service calls. Cisco Nexus9000 devices must be registered to receive entitled support services. Press Enter at anytime to skip a dialog. Use ctrl-c at anytime to skip the remaining dialogs. Would you like to enter the basic configuration dialog (yes/no): y Create another login account (yes/no) [n]: n Configure read-only SNMP community string (yes/no) [n]: Configure read-write SNMP community string (yes/no) [n]: Enter the switch name: D01-n9k1 Continue with Out-of-band (mgmt0) management configuration? (yes/no) [y]: Mgmt0 IPv4 address: Mgmt0 IPv4 netmask: Configure the default gateway? (yes/no) [y]: IPv4 address of the default gateway: Configure advanced IP options? (yes/no) [n]: Enable the telnet service? (yes/no) [n]: Enable the ssh service? (yes/no) [y]: Type of ssh key you would like to generate (dsa/rsa) [rsa]: Number of rsa key bits < > [1024]: 2048 Configure the ntp server? (yes/no) [n]: y 15

16 NTP server IPv4 address: Configure default interface layer (L3/L2) [L2]: Configure default switchport interface state (shut/noshut) [noshut]: Configure CoPP system profile (strict/moderate/lenient/dense/skip) [strict]: 2. Review the settings printed to the console. If they are correct, answer yes to apply and save the configuration 3. Wait for the login prompt to make sure that the configuration has been saved prior to proceeding. Cisco Nexus B To set up the initial configuration for the second Cisco Nexus switch complete the following steps: 1. Connect to the serial/console port of the switch 2. The Cisco Nexus B switch should present a configuration dialog identical to that of Cisco Nexus A shown above. Provide the configuration parameters specific to Cisco Nexus B for the following configuration variables. All other parameters should be identical to that of Cisco Nexus A. Admin password Cisco Nexus B Hostname: D01-n9k2 Cisco Nexus B mgmt0 IP address: Cisco Nexus B mgmt0 Netmask: Cisco Nexus B mgmt0 Default Gateway: Cisco Nexus Global Configuration In this section, we look at the configuration necessary on both Cisco Nexus switches to connect to FI, inband Management and other connections necessary. 1. On both Cisco Nexus switches, enable the following features and best practices. feature udld feature lacp feature vpc feature interface-vlan spanning-tree port type network default spanning-tree port type edge bpduguard default spanning-tree port type edge bpdufilter default 2. Create VLANs for SmartStack system. vlan 12 name IB-MGMT vlan 2 name Native-VLAN vlan 900 name VM-Traffic-VLAN900 vlan 901 name VM-Traffic-VLAN901 16

17 Cisco Nexus VPC Configuration Cisco Nexus A To configure virtual port channels (vpcs) for switch A, complete the following steps: From the global configuration mode, create a new vpc domain: vpc domain 155 Make Cisco Nexus A the primary vpc peer by defining a low priority value: role priority 10 Use the management interfaces on the supervisors of the Cisco Nexus switches to establish a keepalive link: peer-keepalive destination source Enable following features for this vpc domain: peer-switch delay restore 150 peer-gateway ip arp synchronize auto-recovery Save the configuration: copy run start Cisco Nexus B To configure vpcs for switch B, complete the following steps: From the global configuration mode, create a new vpc domain: vpc domain 155 Make Cisco Nexus A the primary vpc peer by defining a low priority value: role priority 20 Use the management interfaces on the supervisors of the Cisco Nexus switches to establish a keepalive link: peer-keepalive destination source Enable following features for this vpc domain: peer-switch delay restore 150 peer-gateway ip arp synchronize auto-recovery Save the configuration: copy run start Configure Network Interfaces for the VPC Peer Links: Cisco Nexus A 1. Define a port description for the interfaces connecting to VPC Peer D01-n9k2. 17

18 interface Eth1/53 description VPC Peer D01-n9k2:e1/53 interface Eth1/54 description VPC Peer D01-n9k2:e1/ Apply a port channel to both VPC Peer links and bring up the interfaces. interface Eth1/53,Eth1/54 channel-group 155 mode active no shutdown Define a description for the port-channel connecting to D01-n9k2. interface Po155 description vpc peer-link Make the port-channel a switchport, and configure a trunk to allow in-band management, VM traffic, and the native VLAN. switchport switchport mode trunk switchport trunk native vlan 2 switchport trunk allowed vlan 12, 900, 901 Make this port-channel the VPC peer link and bring it up. vpc peer-link no shutdown copy run start Configure Network Interfaces for the VPC Peer Links: Cisco Nexus B Define a port description for the interfaces connecting to VPC Peer D01-n9k1. interface Eth1/53 description VPC Peer D01-n9k1:e1/53 interface Eth1/54 description VPC Peer D01-n9k1:e1/54 Apply a port channel to both VPC Peer links and bring up the interfaces. interface Eth1/53,Eth1/54 channel-group 155 mode active no shutdown Define a description for the port-channel connecting to D01-n9k1. interface Po155 description vpc peer-link Make the port-channel a switchport, and configure a trunk to allow in-band management, VM traffic, and the native VLAN. switchport switchport mode trunk switchport trunk native vlan 2 switchport trunk allowed vlan 12, 900, 901 Make this port-channel the VPC peer link and bring it up. vpc peer-link no shutdown 18

19 copy run start Cisco Nexus Configuration to Cisco UCS Mini Fabric Interconnect Cisco Nexus A Define a description for the port-channel connecting to D01-Mini1-A. interface Po11 description D01-Mini1-A Make the port-channel a switchport, and configure a trunk to allow in-band management, VM traffic, and the native VLANs. switchport switchport mode trunk switchport trunk native vlan 2 switchport trunk allowed vlan 12, 900, 901 Make the port channel and associated interfaces spanning tree edge ports. spanning-tree port type edge trunk Make this a VPC port-channel and bring it up. vpc 11 no shutdown Define a port description for the interface connecting to D01-Mini1-A. interface Eth1/13 description D01-Mini1-A:p1 Apply it to a port channel and bring up the interface. channel-group 11 force mode active no shutdown Define a description for the port-channel connecting to D01-Mini1-B. interface Po12 description D01-Mini1-B Make the port-channel a switchport, and configure a trunk to allow in-band management, VM traffic VLANs and the native VLAN. switchport switchport mode trunk switchport trunk native vlan 2 switchport trunk allowed vlan 12, 900, 901 Make the port channel and associated interfaces spanning tree edge ports. spanning-tree port type edge trunk 10. Make this a VPC port-channel and bring it up. vpc 12 no shutdown 11. Define a port description for the interface connecting to D01-Mini1-B interface Eth1/14 description D01-Mini1-B:p1 19

20 12. Apply it to a port channel and bring up the interface. Cisco Nexus B channel-group 12 force mode active no shutdown copy run start Define a description for the port-channel connecting to D01-Mini1-A. interface Po11 description D01-Mini1-B Make the port-channel a switchport, and configure a trunk to allow in-band management, VM traffic, and the native VLANs. switchport switchport mode trunk switchport trunk native vlan 2 switchport trunk allowed vlan 12, 900, 901 Make the port channel and associated interfaces spanning tree edge ports. spanning-tree port type edge trunk Make this a VPC port-channel and bring it up. vpc 11 no shutdown Define a port description for the interface connecting to D01-Mini1-A interface Eth1/13 description D01-Mini1-A:p2 Apply it to a port channel and bring up the interface. channel-group 11 force mode active no shutdown Define a description for the port-channel connecting to D01-Mini1-B interface Po12 description D01-Mini1-B Make the port-channel a switchport, and configure a trunk to allow in-band management, and VM traffic VLANs and the native VLAN. switchport switchport mode trunk switchport trunk native vlan 2 switchport trunk allowed vlan 12, 900, 901 Make the port channel and associated interfaces spanning tree edge ports. spanning-tree port type edge trunk 10. Make this a VPC port-channel and bring it up. vpc 12 no shutdown 11. Define a port description for the interface connecting to D01-Mini1-B 20

21 interface Eth1/14 description D01-Mini1-A:p2 12. Apply it to a port channel and bring up the interface. channel-group 12 force mode active no shutdown copy run start Storage Configuration This section provides the procedure for initializing a Nimble Storage array and setting up basic IP connectivity. Note that the dialog below is specific for an iscsi array setup. Nimble Setup Manager The Nimble Setup manager can be downloaded from Infosight at this location: The Nimble Setup manager is part of the Nimble Storage Windows Toolkit. In this instance the Nimble Setup Manager is the only component that needs to be installed. Initialize the Nimble Storage Array In the Windows Start menu, click Nimble Storage > Nimble Setup Manager. Select one of the uninitialized arrays from the Nimble Setup Manager list and click Next. If the array is not visible in Nimble Setup Manager, verif on the same subnet as the Windows host. ports of both controllers are Configure the Nimble OS using the GUI 1. Choose the appropriate group option and click Next. Set up the array but do not join a group. Continue to Step 5. Add the array to an existing group. If you chose to join an existing group, your browser automatically redirects to the login screen of the group leader array. See Add Array to Group Using the GUI to complete the configuration. 2. Provide or change the following initial management settings and click Finish: Array name Group name Management IP address and subnet mask for the eth1 interface Default gateway IP address Optional. Administrator password 3. You may see a warning similar to There is a problem with this website's security certificate. It is safe to ignore this warning and click Continue. 21

22 If prompted, you can also download and accept the certificate. Alternatively, create your own. See the cert command in the Nimble Command Line Reference Guide. Also, if Internet Explorer v7 displays a blank page, clear the browser's cache. The page should be visible after refreshing the browser In the login screen, type the password you set and click Log In. From this point forward, you are in the Nimble OS GUI. The first time you access the Nimble OS GUI, the Nimble Storage License Agreement appears. In the Nimble Storage License Agreement, read the agreement, scroll to the bottom, check the acknowledgment box, and then click Proceed. Provide the Subnet Configuration information for the following sections and click Next: a. Management IP: IP address, Network and Subnet Mask The Management IP is used for the GUI, CLI, and replication. It resides on the management subnet and floats across all "Mgmt only" and "Mgmt + Data" interfaces on that subnet. b. c. Subnet: Subnet label, Network, Netmask, Traffic Type(Data only, Mgmt Only, Mgmt +Data), MTU Maximum Transmission Unit (MTU) Standard (1500) for Management and Jumbo (9000) for TG ports. Ensure that your network switches support Jumbo frame size (9000). The data port IP addresses are assigned to interface pairs, such as TG1 on controller A and TG1 on controller B. If one controller fails, the corresponding port on the remaining controller still has data access. You need to configure two data IP subnets and assign one pair of interfaces to each subnet. To add a data subnet, click Add Data Subnet, provide the required information and click OK. 7. Provide Interface Assignment information for the following sections and click Next: Interface Assignment: For each IP interface, assign it a subnet and a Data IP address within the specified network. For inactive interface, assign the "None" subnet. Diagnostics: Controller A diagnostics IP address within the specified network Controller B diagnostics IP address within the specified network 8. Provide the following Domain information and click Next: Domain Name DNS Servers: Type the hostname or IP address of your DNS server. You can list up to five servers. 9. Provide the following Time information and click Next: Time Zone: Choose the time zone the array is located in. Time (NTP) Server: Type the hostname or IP address of your NTP server. 10. Provide Support information for the following sections and click Finish Alerts 22

23 From Address: This is the address used by the array when sending alerts. It does not need to be a real address. Include the array name for easy identification. Send to Address: Nimble recommends that you check the Send event data to Nimble Storage Support check box. SMTP server hostname or IP address AutoSupport Checking the Send AutoSupport data to Nimble Storage check box enables Nimble Storage Support to monitor your array, notify you of problems, and provide solutions. HTTP Proxy: AutoSupport and software updates require an HTTPS connection to the Internet, either directly or through a proxy server. If a proxy server is required, check the Use HTTP Proxy check box and provide the following information to configure proxy server details: HTTP proxy server hostname or IP address HTTP proxy server port Proxy server user name Proxy server password The system does not test the validity of the SMTP server connection or the addresses that you provided. 12. Click Finish. The Setup Complete screen appears. Click Continue. 13. The Nimble OS home screen appears. Nimble Storage array setup is complete. Nimble Management Tools: InfoSight Register and Login to InfoSight Before you begin It can take up to 24 hours for the array to appear in InfoSight after the first data set is sent. Data sets are configured to be sent around midnight array local time. Changes made right after the data set is sent at midnight might not be reflected in InfoSight for up to 48 hours. Procedure Log in to the InfoSight portal at Click Enroll now to activate your account. If your is not already registered, contact your InfoSight Administrator. If there is no existing, InfoSight Administrator (Super User) registered against your account or you are not sure, contact Nimble Storage Support for assistance. Select the appropriate InfoSight role and enter the array serial number for your customer account. If this is the first account being created for your organization, you should select the Super User role. The number of super users is limited to the total number of arrays that are associated with an account. Click Submit. A temporary password is sent to the address that you specified. You must change your password the first time you log in. 23

24 Configure Arrays to Send Data to InfoSight To take full advantage of the InfoSight monitoring and analysis capabilities, configure your Nimble arrays to send data sets, statistics, and events to Nimble Storage Support. InfoSight recommendations and automatic fault detection are based on data that is sent from your arrays and processed by InfoSight. If you did not configure your Nimble arrays to send this data to Nimble Storage Support during the initial setup, you can change the configuration at any time from the Administration menu in the GUI or by running the group --edit command in the CLI. Before you begin This procedure must be performed in the array GUI. Procedure 1. From the Administration menu in the array GUI, select Alerts and Monitoring > AutoSupport / HTTP Proxy. 2. On the AutoSupport page, select Send AutoSupport data to Nimble Storage Support. 3. Click Test AutoSupport Settings to confirm that AutoSupport is set up correctly. 4. Click Save. Nimble Management Tools: vcenter Plugin Register vcenter Plugins The first steps must be performed on the array GUI, not in Infosight. Nimble Storage has integration vcenter through plugin registration. This gives allows for datastore creation and management using vcenter. The vcenter plugin is supported on ESX 5.5 update 1 and later. The plugin is not supported for: - Multiple datastores located on one LUN - One datastore spanning multiple LUNs - LUNs located on a storage device not made by Nimble Procedure Use a vcenter account that has sufficient privileges to install a plugin (usually a user assigned to the Administrator role). You need to know the vcenter hostname or IP address. The plugin is part of the Nimble OS. To take advantage of it, you must first register the plugin with a vcenter Server. Multiple plugins can be registered on the Nimble array. In turn, each array that registers the plugin adds a tab to the vsphere client. The tab name for the datastore page is "datacenter page-nimble-<groupname>". Registration steps are as follows: 1. From the Nimble OS GUI main menu, select Administration > vcenter Plugin. 2. If the fields are not already filled, enter the vcenter server host name or IP address, user name, and password. 3. Click View Status to see the current status of the plugin. 4. Click Register. If a Security Warning message appears, click Ignore. 5. If you are not sure of which subnet_label to select, the selection that appears when the dialog opens is probably the correct one. 24

25 6. Click View Status again to ensure that the plugin has been registered. 7. Restart the vsphere client. View a List of Installed Plugins A list of all registered plugins on the array can be discovered by completing the following steps: 1. Log into the Nimble OS CLI. 2. At the command prompt, type: vmwplugin --list --username <username> --password <password> --server <server_hostname-address> --port port_number <port number> If no port number is specified, port 443 is selected by default. A list of installed plugins displays. Configure Arrays to Monitor your Virtual Environment Procedure Log in to Go to Administration > Virtual Environment. In the Virtual Environment list, find the array group for which you want to monitor the virtual environment. Click Configure. The Configure Group dialog box opens. Verify that your software version is up to date and that your vcenter plugin is registered. Select Enable in the VM Streaming Data list. Click Update. Configure Setup Notifications for Alerts Procedure 1. On the Wellness page, click Daily Summary s. 25

26 Check Subscribe to daily summary . Enter an address for delivery of the alerts. (Optional) You can click Test to send a test to the address that you indicated. Click Submit to conclude the alerts setup. Server Configuration This section provides detailed procedures for deploying a Cisco Unified Computing System (UCS) in a SmartStack environment. Initial Setup and Configuration This section outlines the initial setup necessary to deploy a new Cisco UCS Mini environment with Cisco Fabric interconnects (UCS-FI-M-6324) and Cisco UCS Manager (UCSM). Cisco UCS 6324 Primary (FI-A) 1. Connect to the console port of the first FI on Cisco UCS Mini. Enter the configuration method: console Enter the setup mode; setup newly or restore from backup.(setup/restore)? Setup You have chosen to setup a new fabric interconnect? Continue? (y/n): y Enforce strong passwords? (y/n) [y]: y Enter the password for "admin": Enter the same password for "admin": Is this fabric interconnect part of a cluster (select 'no' for standalone)? (yes/no) [n]: y Which switch fabric (A B): A Enter the system name: D01-Mini1 Physical switch Mgmt0 IPv4 address: Physical switch Mgmt0 IPv4 netmask: IPv4 address of the default gateway: Cluster IPv4 address: Configure DNS Server IPv4 address? (yes/no) [no]: y DNS IPv4 address: Configure the default domain name? y Default domain name: smartstack.local Join centralized management environment (UCS Central)? (yes/no) [n]: 2. Review the settings printed to the console. If they are correct, answer yes to apply and save the configuration. 3. Wait for the login prompt to make sure that the configuration has been saved prior to proceeding. Cisco UCS 6324 Secondary (FI-B) Connect to the console port on the second FI on Cisco UCS Mini. Enter the configuration method: console Installer has detected the presence of a peer Fabric interconnect. This Fabric interconnect will be added to the cluster. Do you want to continue {y n}? y Enter the admin password for the peer fabric interconnect: Physical switch Mgmt0 IPv4 address: Apply and save the configuration (select no if you want to re-enter)?(yes/no: y 26

27 4. 5. Verify the above setup to ensure the two Cisco UCS FIs formed a cluster by SSH-ing into the FIs and doing: show cluster state log into Cisco UCS Manager using the cluster IP of the Cisco FIs Log in to Cisco UCS Manager (UCS Manager) To log in to the Cisco Unified Computing System (UCS) environment, complete the following steps: 1. Open a web browser and navigate to the Cisco UCS 6324 Fabric Interconnect cluster IP address. 2. Click the Launch UCS Manager link to download the Cisco UCS Manager software. 3. If prompted to accept security certificates, accept as necessary. 4. When prompted, enter admin as the user name and enter the administrative password. 5. Click Login to log in to Cisco UCS Manager. 6. Enter the information for the Anonymous Reporting if desired and click OK. Synchronize Cisco UCS Mini to NTP To synchronize the Cisco UCS environment to the NTP server, complete the following steps: From Cisco UCS Manager, click the Admin tab in the navigation pane. Select All > Timezone Management > Timezone. Right-click and select Add NTP Server. Specify NTP Server IP (For example: ) and click OK, followed by Save Changes. Configure Ports Connected to Switching Infrastructure To configure the ports to be connected to the Cisco Nexus switches as Uplink ports, complete the following steps: From Cisco UCS Manager, click the Equipment tab in the navigation pane. Select Equipment > Fabric Interconnects > Fabric Interconnect A (primary) > Fixed Module. 27

28 Expand Ethernet Ports. Select the first port (For example: Port 1) that connects to Cisco Nexus A switch, right-click and select Configure as Uplink Port Click Yes to confirm the uplink ports and click OK. Repeat for second port (For example: Port 2) that connects to Cisco Nexus B switch. Repeat above steps on Fabric Interconnect B to configure the ports that connect to Cisco Nexus A and B switches as Uplink ports The resulting status on Cisco UCSM GUI should show the ports (Port 1, Port 2) as being up and Enabled on both Fabric Interconnect A and B with an If Role of Network as shown below. Configure PortChannels on Uplink Ports To configure Uplink ports to be connected to the Cisco Nexus switches in a PortChannel, complete the following steps: From Cisco UCS Manager, click the LAN tab in the navigation pane. Select LAN > LAN Cloud > Fabric A > Port Channels. Right-click and select Create Port Channel. Specify a Name, ID and select the ports to put in the channel (For example: Eth Interface 1/1 and Eth Interface 1/2) and Click Finish to create PortChannel. The resulting configuration is shown below. 28

29 5. Repeat above steps for Fabric B. The resulting configuration is shown below. Configure Ports Connected to Storage Array To configure ports connected to Nimble array as Appliance ports, complete the following steps: From Cisco UCS Manager, click the Equipment tab in the navigation pane. Select Equipment > Fabric Interconnects > Fabric Interconnect A (primary) > Fixed Module. Expand Ethernet Ports. Select the first port (For example: Port 3) that directly connects to Controller A on Nimble array, rightclick and select Configure as Appliance Port Click Yes to confirm the appliance ports and click OK to confirm. Repeat for second port (For example: Port 4) that connects to Controller B on Nimble array 29

30 5. 6. Repeat above steps on the Fabric Interconnect B to configure the ports connected to Nimble Controller A and B as Appliance ports The resulting status on Cisco UCS Manager GUI should show the ports (Port 3, Port 4) as being up and Enabled on both Fabric Interconnect A and B with an IfRole of Appliance Storage as shown below. Server Configuration Workflow: vnic Template Creation To create a Service Profile Template to rapidly configure and deploy Cisco UCS servers in a SmartStack design, requires the creation of multiple vnic templates. The figure below shows the high level workflow for creating vnic Templates. The next few sections will cover the configuration of the individual steps in the workflow below. 30

31 Figure 4 vnic Template Workflow Create LAN Pools MAC Address Pool Network Control Policy for Uplink vnic Templates Create LAN Policies Management Application Data Network Control Policy for Appliance Ports QOS and Jumbo Frame Policy for iscsi traffic Create Management VLANs Create Data VLANs Storage Create iscsi VLANs Storage traffic on Fabric A Storage traffic on Fabric B Create VLANs: Management VLAN on Uplink Ports to Cisco Nexus 9000 Series Switches A management VLAN is required in order to provide in-band access to the Cisco UCS blades. The management VLAN is necessary for in-band management access to hosts and virtual machines on Cisco UCS Mini. To create VLANs on an uplink port to Cisco Nexus 9000 Series switches, complete the following steps: 1. From Cisco UCS Manager, click the LAN tab in the navigation pane. 2. Select LAN > LAN Cloud > VLANs. 3. Right-click and select Create VLANs. Specify a name (For example: MGMT) and VLAN ID (For example: 12). 31

32 4. Determine whether or not the newly created VLAN should be a trunked VLAN or a native VLAN to the upstream switch. Either option is acceptable, but it needs to match what the upstream switch is set to. If the newly created VLAN is a native VLAN, select the VLAN, right-click and select Set as Native VLAN from the list. 5. Using the steps above, also create VLAN for vmotion (For example: 3000) which will use the same vnic as Management in this design. vmotion can also use a separate dedicate vnic. Create VLANs: Application Data VLANs on Uplink Ports to Cisco Nexus 9000 Series Switches Repeat the steps used to create the management VLAN above for every VLAN that needs to be trunked through the Cisco Nexus 9000 series switches to other parts of the network. These VLANs were created for testing the SmartStack architecture. Per security best practices, the default native VLAN (VLAN 1) was changed to VLAN 2. 32

33 Create VLANs: Appliance Port VLANs to Nimble Storage The Appliance VLAN carries the storage related traffic to the directly attached Nimble array. An Appliance VLAN is specific to a single Fabric Interconnect. These VLANs do not span across multiple Fabric Interconnects. Therefore, each Appliance port VLAN is a single broadcast domain. To configure the VLANs, complete the following steps: 1. From Cisco UCS Manager, select the LAN tab in the navigation pane. 2. Select LAN > Appliances > Fabric A > VLANs. 3. Right-click and select Create VLANs. 4. Specify the VLAN Name/Prefix (For example: iscsi-a-san) and VLAN ID (For example: 3010) for connecting to Fabric Interconnect A. Click OK. The VLAN should not be a routed VLAN, but still should be unique for your environment. 5. Select LAN > Appliances > Fabric B > VLANs. 6. Repeat the above process for the VLAN used between Fabric Interconnect B and Nimble Array. In testing, storage VLAN used for Fabric Interconnect B was: iscsi-b-san and VLAN Navigate to LAN > LAN Cloud > Fabric A and right-click to create SCSI-A-SAN VLAN under LAN Cloud. 8. Navigate to LAN > LAN Cloud > Fabric B and right-click to create SCSI-B-SAN VLAN under LAN Cloud. Create LAN Pools: Mac Address Pools For ease of troubleshooting, the 4th and 5th octet in the mac-address is modified in the SmartStack design to reflect whether that mac-address uses Fabric A or Fabric B. 33

34 Cisco UCS allows MAC address pool creation and allocation. Having organized MAC pool allocation can be extremely beneficial to any troubleshooting efforts that might be needed. Create MAC Pool for a Presence in both Fabric Interconnect A The MAC addresses in this pool will be used for traffic using Fabric Interconnect A. 1. From Cisco UCS Manager, click the LAN tab in the navigation pane. 2. Select LAN > Pools > root > Mac Pools. 3. Right-click and select Create Mac Pool. 4. Specify a name (For example: FI-A) that identifies this pool is specific to Fabric Interconnect A. 5. Select the Assignment Order as Sequential and click Next. 6. Click [+] Add to add a new MAC pool. 7. For ease-of-troubleshooting, change the 4 th and 5 th octet to include the letters AA:AA to indicate a presence only in Fabric Interconnect A. Generally speaking, the first three octets of a mac-address should not be changed. 8. Select a size of 256 MACs or less and select OK and then Finish to add the MAC pool. Create MAC Pool for a Presence in both Fabric Interconnect B The MAC addresses in the pool will be used for traffic using Fabric Interconnect B. 1. From Cisco UCS Manager, click the LAN tab in the navigation pane. 2. Select LAN > Pools > root > Mac Pools. 3. Right-click and select Create Mac Pool. 4. Specify a name (For example: FI-B) that identifies this pool is specific to Fabric Interconnect B. 5. Select the Assignment Order as Sequential and click Next. 6. Click [+] Add to add a new MAC pool. 7. For ease-of-troubleshooting, change the 4 th and 5 th octet to include the letters BB:BB to indicate a presence only in Fabric Interconnect B. Generally, the first three octets of a mac-address should not be changed. 8. Select a size of 256 MACs or less and select OK and then Finish to add the MAC pool. MAC Pool Summary View The resulting configuration is shown below. 34

35 Create LAN Policies: QoS and Jumbo Frame Proper QoS configuration is required in order to allow proper MTU size and traffic priority. The most important thing to keep in mind is that the CoS / QoS level needs to be the same for the entire path from the Nimble Storage array to the server blade. To create LAN policies for QoS and Jumbo frames, complete the following steps: 1. From Cisco UCS Manager, select the LAN tab in the navigation pane. 2. Select LAN > LAN Cloud > QOS System Class. 3. Select the Enabled checkbox for the Best Effort. 4. In the Best Effort row change the MTU to be a value of 9000 and click Save Changes. 5. Select LAN tab in the navigation pane. 6. Select LAN > Policies > root > QOS Policies. 7. Right-click and select Create QoS Policy. 8. Specify a policy Name (For example: Nimble-QoS) and select Priority as Best Effort. Click OK to save. 35

36 Create LAN Policies: Network Control Policy for Uplinks to Cisco Nexus Switches For Uplink ports connected to Cisco Nexus switches, the policy is used to enable Cisco Discovery Protocol (CDP). CDP allows devices to discover and learn about devices connected to the ports where CDP is enabled and is a very useful for troubleshooting. To create LAN policies for Network Control, complete the following steps: 1. From Cisco UCS Manager, select the LAN tab in the navigation pane. 2. Select LAN > Policies > LAN Cloud > root > Network Control Policies. 3. Right-click and select Create Network Control Policy. 4. Specify a Name for the network control policy (For example: Enable_CDP). 5. Select Enabled for CDP and click OK to create network control policy. 36

37 Create LAN Policies: Network Control Policy for Storage vnics A Network Control Policy controls how a resource will behave in the event that a Fabric Interconnects upstream connectivity becomes unavailable. A Network Control policy is necessary under LAN Cloud so as to apply the policy when creating iscsi-a and iscsi-b vnic templates under LAN Cloud. An identical policy is also created under Appliances but this policy is for applying it directly to the Appliance port. To create LAN policies for storage vnics, complete the following steps: 1. From Cisco UCS Manager, select the LAN tab in the navigation pane. 2. Select LAN > Policies > LAN Cloud > root > Network Control Policies. 3. Right-click and select Create Network Control Policy. 4. Specify a Name for the network control policy (For example: Nimble-NCP). 5. Select the Action on Uplink Fail to be Warning and click OK to create network control policy. 37

38 Create LAN Policies: vnic Templates for Management Traffic To create virtual network interface card (vnic) templates for Management traffic in a Cisco UCS environment, complete the following steps. Two management vnics are created for redundancy through Fabric A and another through Fabric B. one From Cisco UCS Manager, select the LAN tab in the navigation pane. Select LAN > Policies > root > vnic Templates. Right-click and select Create vnic Template. Specify a template Name (For example: MGMT-A) for the policy. Keep Fabric A selected and leave Enable Failover checkbox unchecked. Under Target, make sure that the VM checkbox is not selected. Select Updating Template as the Template Type. Under VLANs, select the checkboxes MGMT, vmotion. For MTU, enter 9000 since vmotion traffic will use this vnic. 10. For MAC Pool, select FI-A. 11. For Network Control Policy, select Enable_CDP. 38

39 12. Click OK twice to create the vnic template. The resulting configuration is as shown below: 13. Repeat same steps to create a vnic (MGMT-B) template through Fabric B with the same parameters as MGMT-A but using FI-B MAC Pool. The resulting configuration is as shown below: 39

40 Create LAN Policies: vnic Templates for Uplink Port Traffic To create virtual network interface card (vnic) templates for Application Data traffic in a Cisco UCS environment, complete the following steps. Two Application vnics are created for redundancy one through Fabric A and another through Fabric B From Cisco UCS Manager, select the LAN tab in the navigation pane. Select LAN > Policies > root > vnic Templates. Right-click and select Create vnic Template. Specify a template Name (For example: vnic-a) for the policy. Keep Fabric A selected and leave Enable Failover checkbox unchecked. Under Target, make sure that the VM checkbox is not selected. Select Updating Template as the Template Type. Under VLANs, select the checkboxes default, Data-v900, Data-v901. Set default as the native VLAN. 10. For MTU, enter MTU of 9000 can be used if needed. 11. For MAC Pool, select FI-A. 12. For Network Control Policy, select Enable_CDP. 40

41 13. Click OK twice to create the vnic template. The resulting configuration is as shown below: 41

42 14. Repeat same steps to create a vnic (vnic-b) template through Fabric B with the same parameters as vnic-a but using FI-B MAC Pool. The resulting configuration is as shown below: Create LAN Policies: vnic Templates for Appliance Port Traffic To create virtual network interface card (vnic) templates for the Appliance ports on Cisco UCS environment, complete the following steps. Two storage vnics are created for redundancy one through Fabric A and another through Fabric B From Cisco UCS Manager, select the LAN tab in the navigation pane. Select LAN > Policies > root > vnic Templates. Right-click and select Create vnic Template. Specify a template Name (For example: iscsi-a) for the policy. Keep Fabric A selected and leave Enable Failover checkbox unchecked. Under Target, make sure that the VM checkbox is not selected. Select Updating Template as the Template Type. Under VLANs, select the checkboxes for only iscsi-a-san VLAN. Set iscsi-a-san as the native VLAN 10. For MTU, enter For MAC Pool, select FI-A. 42

43 12. For QoS Policy, select Nimble-QoS. 13. For Network Control Policy, select Nimble-NCP. 14. Click OK twice to create the vnic template. The resulting configuration is as shown below: 15. Repeat same steps to create a vnic (iscsi-b)template through Fabric B with the same parameters as iscsi-a except that iscsi-b will use MAC Pool FI-B and iscsi-b-san will be the VLAN instead of iscsi-a-san. The resulting configuration is as shown below. 43

44 Server Configuration Workflow: Appliance Port Policies In the SmartStack design, the Nimble CS300 array is directly attached to Appliance Ports on Cisco UCS Mini Fabric Interconnect ports. This requires a number of policies to be applied to the Appliance port for the SmartStack platform to function optimally. The figure below shows the workflow for defining and applying the correct policies on Appliance Ports with direct attached iscsi storage. Figure 5 Appliance Port Policy Workflow Create Network Control Policy for Appliance Port Create Flow Control Policy for Appliance Port Apply Policies to Appliance Ports on Fabric A and Fabric B Create LAN Policies: Network Control Policy for Appliance Port A Network Control Policy controls how a resource will behave in the event that a Fabric Interconnects upstream connectivity becomes unavailable. In particular, this policy needs to exist for Appliance ports to specify the behavior in the event of an upstream device failover. For Appliance ports connected to Nimble Storage arrays, the policy action should be set to not failover. This will allow the host MPIO software to 44

45 handle failover scenarios. An identical policy is also created under LAN > LAN Cloud but for applying it to vnic Template. To create a Network Control policy for the Appliance Port, complete the following steps: From Cisco UCS Manager, select the LAN tab in the navigation pane. Select LAN > Policies > Appliances > Network Control Policies. Right-click and select Create Network Control Policy. Specify a name for the network control policy (For example: Nimble-NCP). Select the Action on Uplink Fail to be Warning and click OK to create network control policy. Create LAN Policies: Flow Control Policy for Appliance Port Flow control determines how congestion control is negotiated between the Nimble Storage array and the directly connected Fabric Interconnect switch ports. To configure this policy, complete the following steps: From Cisco UCS Manager, select the LAN tab in the navigation pane. Select LAN > Policies > root > Flow Control Policies. Right-click and select Create Flow Control Policy. Specify a name (For example: Nimble-Flow) for the policy. Set Receive and Send flow control to On. Leave the Priority set to Auto. 45

46 6. Click OK twice to create flow control policy. Apply Policies to Appliance Port To apply policies to the Appliance Port, complete the following steps: From Cisco UCS Manager, select the LAN tab in the navigation pane. Select Appliances > Fabric A > Interfaces Select the first port (For example: Appliance Interface 1/3) Set the Priority to be the correct QoS / CoS priority level. (Best Effort in this case) Set the Network Control Policy to be the one previously created (For example: Nimble-NCP) Set the Flow Control policy to be the one previously created (For example: Nimble-Flow). Select the VLAN (For example: iscsi-a-san) used for iscsi Traffic through Fabric A. 46

47 8. Click Save Changes to apply the policies. 9. Repeat the above steps for other interfaces on Fabric A by selecting Fabric A > Interfaces > Appliance Interface 1/ Repeat the above steps for interfaces on Fabric B by selecting Fabric B > Interfaces > Appliance Interface 1/3, followed by Fabric B > Interfaces > Appliance Interface 1/4. Note that that VLAN for iscsi traffic through Fabric B will be: iscsi-b-san. 47

48 Server Configuration Workflow: Server Policies The next step towards creating Service Profile Template is the creation of Server Policies. The figure below shows the workflow for creating server policies. Figure 6 Server Policy Workflow Create Power Control Policy Create Server Pool Qualification Policy Create BIOS Policy Create iscsi Boot Adapter Policy Server Policies Create Local Disk Configuration Policy Create Boot Policy Create Maintenance Policy Create Host Firmware Package Policy Create UUID Suffix Pool Create Server Policies: Power Control Policy To create a power control policy for the Cisco UCS environment, complete the following steps: In Cisco UCS Manager, click the Servers tab in the navigation pane. Select Servers > Policies > root > Power Control Policies. Right-click and select Create Power Control Policy. Enter No-Power-Cap as the power control policy name. Change the power capping setting to No Cap. Click OK twice to create the power control policy. 48

49 Create Server Policies: Server Pool Qualification Policy To create an optional server pool qualification policy for the Cisco UCS environment, complete the following steps: This example creates a policy for a Cisco UCS B200-M4 server. 1. In Cisco UCS Manager, click the Servers tab in the navigation pane. 2. Select Policies > root > Server Pool Policy Qualifications. 3. Right-click and select Create Server Pool Policy Qualification. 4. Enter UCSB-B200-M4 as the name for the policy. 5. Select Create Server PID Qualifications. 6. Enter UCSB-B200-M4 as the PID. 49

50 7. Click OK twice to create the server pool qualification policy. Create Server Policies: BIOS Policy To create a server BIOS policy for the Cisco UCS environment, complete the following steps: 1. In Cisco UCS Manager, click the Servers tab in the navigation pane. 2. Select Policies > root > BIOS Policies. 3. Right-click and select Create BIOS Policy. 4. Enter VM-Host-Infra as the BIOS policy name. 5. In the Main screen, change the Quiet Boot setting to Disabled. 50

51 6. Click Next. 7. Change Turbo Boost to Enabled. 8. Change Enhanced Intel Speedstep to Enabled. 9. Change Hyper Threading to Enabled. 10. Change Core Multi Processing to all. 11. Change Execution Disabled Bit to Enabled. 12. Change Virtualization Technology (VT) to Enabled. 13. Change Direct Cache Access to Enabled. 14. Change CPU Performance to Enterprise. 51

52 15. Click Next to go the Intel Directed IO Screen. 16. Change the VT for Direct IO to Enabled. 17. Click Next to go the RAS Memory screen. 18. Change the Memory RAS Config to maximum-performance. 19. Change NUMA to Enabled. 20. Change LV DDR Mode to performance-mode. 21. Click Finish and OK to create the BIOS policy. Create Server Policies: iscsi Boot Adapter Policy To create a server iscsi Adapter policy for the Cisco UCS environment, complete the following steps: 52

53 In Cisco UCS Manager, click the Servers tab in the navigation pane. Select Policies > root > Adapter Policies. Right-click and select Create iscsi Adapter Policy. Enter iscsi-boot as the iscsi Boot Adapter policy name. 5. Click OK twice to create the iscsi Adapter policy Create Server Policies: Local Disk Configuration Policy To create a local disk configuration policy for the Cisco UCS environment, complete the following steps: In Cisco UCS Manager, click the Servers tab in the navigation pane. Select Policies > root > Local Disk Config Policies. Right-click and select Create Local Disk Configuration Policy. Enter iscsi-boot as the iscsi Boot Adapter policy name. Click OK twice to complete the local disk configuration policy. 53

54 Create Server Policies: Boot Policy To create server boot policy, complete the following steps: 1. In Cisco UCS Manager, click the Servers tab in the navigation pane. 2. Select Policies > root > Boot Policies. 3. Right-click and select Create Boot Policy. 4. Enter Nimble-iSCSI as the Boot policy name. Do not select the Reboot on Boot Order Change checkbox 5. Expand the Local Devices drop-down menu, select Add Remote CD/DVD. 6. Expand the iscsi vnics drop-down menu and select Add iscsi Boot. 54

55 7. In the Add iscsi Boot dialog box, enter iscsi-a-boot in the iscsi vnic field. 8. Click OK to add the iscsi boot initiator. 9. From the iscsi vnics drop-down menu, select Add iscsi Boot. 10. Enter iscsi-b-boot as the iscsi vnic. 11. Click OK to add the iscsi boot initiator. 12. Click OK again twice to create the boot policy. The resulting configuration is as shown below. 55

56 Create Server Policies: Maintenance Policy To update the default Maintenance Policy, complete the following steps: In Cisco UCS Manager, click the Servers tab in the navigation pane. Select Policies > root > Maintenance Policies. Right-click and select Create Maintenance Policy. Specify a name for the policy (For example: User-ACK). Change the Reboot Policy to User Ack. Click OK twice to create the maintenance policy. Create Server Polices: Host Firmware Package Policy Firmware management policies allow the administrator to select the corresponding packages for a given server con-figuration. These policies often include packages for adapter, BIOS, board controller, FC adapters, host bus adapter (HBA) option ROM, and storage controller properties. To create a firmware management policy for a given server configuration in the Cisco UCS environment, complete the following steps: In Cisco UCS Manager, click the Servers tab in the navigation pane. Select Policies > root > Host Firmware Packages. Right-click Host Firmware Packages and select Create Host Firmware Package. Enter VM-Host-Infra as the name of the host firmware package. Leave Simple selected. Select the version 3.0(2c) for both the Blade Package and Rack Package. 56

57 7. Click OK twice to create the host firmware package. Server Configuration Workflow: Server, LAN and SAN Pools The next step towards creating Service Profile Template is the creation of the remaining Sever, LAN and SAN Pools. The figure below shows all the pools that need to be created and the grey box represents a pool that was created in an earlier section of this document. Figure 7 Pool Creation Workflow Create LAN Mac Address Pool Create Server, LAN and SAN Pools Create UUID Suffix Pool Create IP Pools Create iscsi IQN Pool Create Server Pools: UUID Suffix Pool To configure the necessary universally unique identifier (UUID) suffix pool for the Cisco UCS environment, complete the following steps: 1. From Cisco UCS Manager, select Servers tab in the navigation pane. 57

58 2. Select Servers > Pools > root > UUID Suffix Pools. 3. Right-click and select Create UUID Suffix Pool. 4. Specify a Name for the UUID suffix pool and click Next. 5. Click [+] Add to add a block of UUIDs. 6. Alternatively, you can also modify the default pool and allocate/modify a UUID block. 7. Keep the From field at the default setting. Specify a block size (For example: 32) that is sufficient to support the available blade or server resources. 8. Click OK, click Finish and click OK again to create UUID Pool. Create LAN Pools: IP Pools Management IP pool: Add Block of IP Addresses for KVM Access To create a block of IP addresses for server Keyboard, Video, Mouse (KVM) access in the Cisco UCS environment, complete the following steps: This block of IP addresses should be in the same subnet as the management IP addresses for the Cisco UCS Manager. 1. From Cisco UCS Manager, click the LAN tab in the navigation pane. 2. Select LAN > Pools > root > IP Pools. 3. Right-click and select Create IP Pool. 4. Specify a Name (For example: ext-mgmt) for the pool and click Next. 5. Click [+] Add to add a new IP block pool. 6. Enter the starting IP address of the block and the number of IP addresses required, and the subnet and gateway information. 58

59 7. Click OK and then Finish to create the IP block. iscsi Initiator IP Pool: Add Block of IP Addresses Exclusively for iscsi Traffic on Fabric Interconnect A To allocate a pool of IP addresses for iscsi data traffic in Fabric Interconnect A, complete the following steps. This block of IPs will align to the IP address range in the Nimble Storage array TG1 interface. 1. From Cisco UCS Manager, click the LAN tab in the navigation pane. 2. Select LAN > Pools > root > IP Pools. 3. Right-click and select Create IP Pool. 4. Specify a Name (For example: iscsi-a) for the pool that is specific to the traffic going to Fabric Interconnect A. 5. Set the Assignment Order to be Sequential and click Next. 6. Click [+] Add to add a new IP block pool. 7. Enter the starting IP address of the block and the number of IP addresses required, and the subnet. No other information should be entered. 8. Click OK and then Finish to create the IP block. iscsi Initiator IP Pool: Add Block of IP Addresses Exclusively for iscsi Traffic on Fabric Interconnect B To allocate a pool of IP addresses for iscsi data traffic in Fabric Interconnect B, complete the following steps. This block of IPs will align to the IP address range in the Nimble Storage array TG2 interface. 1. From Cisco UCS Manager, click the LAN tab in the navigation pane. 2. Select LAN > Pools > root > IP Pools. 3. Right-click and select Create IP Pool. 4. Specify a Name (For example: iscsi-b) for the pool that is specific to the traffic going to Fabric Interconnect B. 5. Set the Assignment Order to be Sequential and click Next. 6. Select [+] Add to add a new IP block pool. 7. Enter the starting IP address of the block and the number of IP addresses required, and the subnet. No other information should be entered. 8. Click OK and then Finish to create the IP block. 59

60 IP Pool Summary View The resulting configuration is shown in the below figure. Create SAN Pools: iscsi IQN Pools Cisco UCS allows you to create IQN pools that are used for the host initiators. This configuration will allow for a single Service Profile level IQN and so only one needs to be created per host. To create iscsi IQN pools, complete the following steps: From Cisco UCS Manager, click the SAN tab in the navigation pane. Select SAN > Pools > root > IQN Pools. Right-click and select Create IQN Suffix Pool. Specify a name (For example: ESX-hosts) for the pool. Specify a Cisco UCS prefix name. You can use a canonical or non-canonical name depending on the host OS requirements. A good example of a canonical prefix is iqn com.xyz-company. A non-canonical prefix is iqn.ucs-blade. Select the Assignment Order to be Sequential and select Next. 60

61 Click [+] Add to add a new IQN block. The Suffix can be anything, but typically it is the same as the intended hostname of the block of hosts to be created. Specify a suffix (For example: esx-host) and a size equal to the number of hosts so 4 for four servers. Click OK and Finish to create IQN Suffix Pool. 61

62 Server Configuration Workflow: Service Profile Template Creation Service Profile Templates will be used to generate the service profile/configuration for the servers in a SmartStack deployment. The figure below shows the Pools, Policies, and other configuration that are required for creating a Service Profile Template. Grey boxes represent configuration that was completed in an earlier section of this document. Figure 8 Service Profile Template Workflow UUID Suffix Pool (default) Networking Storage Create vnics to connect to LAN, including LAN iscsi vnics Create iscsi vnics to connect to SAN using LAN iscsi vnics as overlay Local Disk Configuration Policy vnic Template iscsi IQN Pool iscsi Vlan for Fabric A iscsi Vlan for Fabric B iscsi Adapter Policy Service Profile Template vnic/vhba Placement Server Boot Policy Boot Order Initiator IP Address Policy Server Pools Server Assignment Server Host Firmware Package Server Maintenancy Policy Operational Policies Server Power Control Policy Server BIOS Policy 62

63 Create Service Profile Template To create the service profile templates, complete the following steps: 1. From Cisco UCS Manager, click the Servers tab in the navigation pane. 2. Select Servers > Service Profile Template > root. 3. Right-click root and select Create Service Profile Template to open the Create Service Profile Template wizard. 4. In the Identify the Service Profile Template screen, configure the following: a. b. c. Enter ESX-SANboot-template as the name for the service profile template. Select the Updating Template option. Under UUID, select default as the UUID pool. d. Click Next. Service Profile Template Wizard: Networking To crate the Service Profile for Networking, complete the following steps: 1. In the Networking screen, configure the following: 63

64 2. Dynamic vnic Connection Policy leave it default. 3. To configure the LAN connectivity, select Expert option Click the [+] Add button to add a vnic to connect to the LAN. In the Create vnic dialog box, enter vnic-a as the name for the vnic. Select the Use vnic Template checkbox. In the vnic Template list, select vnic-a. In the Adapter Policy list, select VMWare. 64

65 9. Click OK to add this vnic to the template. 10. On the Networking screen, click the upper [+] Add button to add another vnic to the template. 65

66 11. Repeat the steps for vnic-a but use the Name: vnic-b and vnic Template: vnic-b. 12. On the Networking screen, click the [+] Add button to add another vnic to the template. 66

67 13. Repeat the steps for vnic-a but use the Name: iscsi-a and vnic Template: iscsi-a. 14. Click OK to add this vnic to the template. 15. On the Networking screen, click the [+] Add button to add another vnic to the template. 16. Repeat the steps for vnic-a but use the Name: iscsi-b and vnic Template: iscsi-b. 67

68 17. Click OK to add this vnic to the template. 18. Review the Networking screen to confirm that all four vnics were created. 68

69 19. On the Networking screen, expand the iscsi vnics section and select ESX-Hosts for the Initiator Name Assignment. 69

70 20. Click the [+] Add button to add a iscsi vnic to the template for the server to use. 21. Specify a Name: iscsi-a-boot. Select the Overlay vnic: iscsi-a, iscsi Adapter Policy: iscsi-boot, and VLAN: iscsi-a-san. Do not select a MAC Address Assignment. 22. Click OK to create the iscsi vnic. 23. On the Networking screen, click the [+] Add button to add another iscsi vnic to the template. 24. Repeat the steps for iscsi-a, select Name: iscsi-b-boot, Overlay vnic: iscsi-b, iscsi Adapter Policy: iscsi-boot, and VLAN: iscsi-b-san. Do not select a MAC Address Assignment. 70

71 25. Click OK to create the iscsi vnic. 26. Review the table in the Networking page to confirm that both iscsi vnics were created. 71

72 -B and vnic-b uswhen the configuration wizard completes. 27. Click Next. Service Profile Template Wizard: Storage In the Storage screen, complete the following steps: 1. For the Local Disk Configuration Policy, select SAN-Boot policy for server with no local disks. 72

73 2. To configure SAN connectivity, select No vhbas option Click Next. In the Zoning screen, click Next to skip this configuration. In the vnic/vhba Placement screen, choose default options and click Next. In the vmedia Policy screen, click Next to skip this configuration. Service Profile Template Wizard: Boot Policy In the Server Boot Order screen, select Nimble-iSCSI for the Boot Policy and complete the following steps. This policy was created in an earlier step. 1. Expand iscsi in the Boot Order section. 2. Select iscsi-a-boot. 73

74 3. Click Set iscsi Boot Parameters button. 4. In the Set iscsi Boot Parameters window, select the Initiator IP Address Policy: SANboot-FI-A. 74

75 75

76 5. Select iscsi Static Target Interface. Click [+] Add to add a static target. 6. In the Create iscsi Target window, specify a placeholder name (For example: changeme) and the discovery IP address ( ) for iscsi-a path through Fabric A. Click OK to complete. 7. From the Server Boot Order screen, repeat the above steps by selecting iscsi-b-boot and then click on Set iscsi Boot Parameters to specify changeme as the iscsi Target Name and iscsi discovery IPv4 Address as for iscsi-b through Fabric B. Click OK to complete and Next to continue. 76

77 Service Profile Template Wizard: Maintenance Policy In the Maintenance Policy screen, complete the following steps: 1. Select User-ACK for the Maintenance Policy. This policy was created in an earlier step. Click Next to continue. 2. Click Next. Service Profile Template Wizard: Server Assignment In the Server Assignment screen, select VM-Host-Infra for the Host Firmware Package Policy. This policy was created in an earlier step. Click Next to continue. 77

78 Service Profile Template Wizard: Operational Policies In the Operational Policies screen, select VM-Host-Infra for the BIOS Policy. For the Power Control Policy, select No-Power-Cap for the policy. These policies were created in an earlier step. Click Finish to complete Service Profile Template creation. 78

79 Cisco UCS Configuration Backup The Cisco UCS Configuration should be backed up using the procedures found in the following link: For details, see: Deploying a New Server Generate a Service Profile for the Host from the Service Profile Template Using the service profile template created in the previous step, complete the following steps: Generate a service profile and in the next section, associate it with the newly deployed host. 1. From Cisco UCS Manager, click the Servers tab in the navigation pane 2. Select Servers > Service Profile Templates > root. 79

80 3. Select the Service Profile Template created in earlier steps (For example: ESX-SANboot-template). 4. Right-click on the template (For example: ESX-SANboot-template) and select Create Service Profiles from Template. Enter the naming scheme and number of service profiles to create and click OK. 80

81 Associate the Service Profile with the Host To associate the service profile created in previous step with the newly deployed host, complete the following steps: 1. From Cisco UCS Manager, click the Equipment tab in the navigation pane. 2. Select Equipment > Chassis > Chassis 1 (primary) > Servers 3. Select the server to associate the profile. 4. Right-click and select Associate Service Profile. 5. Select the newly generated service profile to associate with this server and click OK. 6. When the service profile is associated with the server, the in the right pane of the window) will go from Unassociated to OK. iscsi SAN Boot Setup - Create Initiator Group for the ESXi host This section covers the details of the setup required to bring up a new ESXi host using iscsi SAN boot. Configuration will be required on the Cisco UCS Manager managing the host and on the Nimble CS-300. Use Nimble CSfollowing information. eate the Initiator Group. This setup requires the User provided name for Initiator Group (For example: esx-host2) 81

82 iscsi Qualified Name(IQN) of the Initiator/ESXi host IP address of the Initiator or wild card Complete the following steps: 1. From Cisco UCSM web interface, go to Servers tab, select the server being deployed (For example: esxhost2) and note the Initiator name of the host (For example: iqn.com.ucs-blade:esx-blade:2). 2. From the Nimble web management interface, go to Manage > Initiator Groups. 82

83 3. Click Create/Edit. Fill in the Name and IQN (For example: iqn.com.ucs-blade:esx-blade:2)value for the host from Cisco UCSM see earlier step. Click OK. 83

84 In this setup, IP address of the initiator was left as a wild card (*) and uses IQN of the host to restrict access to the storage volume iscsi SAN Boot Setup - Create Boot Volume for the host information: Web Management interface to configure the boot volume. This setup requires the following User specified name for boot volume for the host (For example: esx-host-2-boot) Performance Policy (For example: VMware ESX5) Policy for accessing volume (For example: unrestricted or limit access) Size of the boot volume (For example: 20G) Data protection policy (For example: unprotected since it is a boot volume) Complete the following steps: 1. Web Management interface, go to Manage > Volumes. Click New Volume and provide Volume Name, Performance Policy and Access Control policy for this volume. Click Next. 84

85 At the time of CVD validation, VMware Performance Policy for ESXi6 was not available as an option so ESXI5 was used. 85

86 2. Specify the Volume Size and click Next. 86

87 3. Specify the volume Protection policy and click Finish. iscsi SAN Boot Setup - Configure the iscsi Target on the ESXi Host This setup requires the iscsi target name of the boot volume (esx-host2-boot) created in the previous step. However, available by SSHing into the Nimble array. To configure the iscsi target on the ESXI Host, complete the following steps: 1. Use an SSH client such as Putty to SSH into Nimble array and execute the commands shown in the figure. Copy the iscsi target name to paste in a following step. Commands are: a. vol --list b. vol info <name_of_boot_volume> grep iscsi target 2. From the Cisco UCSM HTML interface, select Servers tab and then select Servers > Service Profiles > root > esx-host2. 3. On the window to the right, select the Boot Order tab. Then select either Modify Boot Policy or go to Boot Order section to the list of boot devices and select iscsi. 87

88 4. Expand iscsi and select the primary iscsi-a-boot device and click the Set iscsi Boot Parameters button to open the iscsi Boot configuration. Repeat this step for iscsi-b-boot. 5. From the Set Boot Parameters configuration window, go to the iscsi static Target Interface section and select the static target interface with the name "changeme". Note that the host inherited "changeme" configuration from the Service Template that was used to derive the Service Profile for the host. 88

89 6. Click Info at the bottom to open the Modify the iscsi Static Target field with the iscsi target copied in Step1. 89

90 7. Click OK to confirm twice, click Yes to the changes and click OK again. 8. Repeat the above steps to change the iscsi target for the secondary boot device: iscsi-b-boot with the same info from Step1. 9. Go to Pending Requests in the top toolbar and select Reboot Now. Click Apply and OK to reboot the host immediately. 90

91 ESXi 6.0 SAN Boot Installation This section provides detailed instructions for installing VMware ESXi 6.0 Update 1 in a SmartStack environment. After the procedures are completed, the SAN-booted ESXi hosts will be provisioned. Several methods exist for installing ESXi in a VMware environment. These procedures focus on how to use the built-in Keyboard, Video, Mouse (KVM) console and virtual media features in Cisco UCS Manager to map remote installation media to individual servers and connect to their boot volumes. A Cisco Custom ESXi 6.0 ISO file which is downloaded from VMware and positioned on a Windows server used to KVM console into the server. The custom image is required as it contains custom Cisco drivers. KVM Console into Host from Cisco UCS Manager Web Interface To create the KVM Console into the host, complete the followings steps: 1. Login to Cisco UCSM using a web browser use the Cisco FI cluster IP address and admin username and password to log in. 2. Download the Cisco Custom ISO for ESXi from the VMware website. 3. From the main Cisco UCSM menu, click the Servers tab. 4. Select Servers > Service Profiles > root > esx-host Right-click esx-host-2 and select KVM Console. Prepare the Host for ESXi Install To prepare the host for the ESXi installation, complete the following steps: 1. In the KVM window, select Virtual Media from the top menu. 91

92 2. Click Activate Virtual Devices, select Accept this Session and then click Apply. 3. Go back to Virtual Media menu option and pick the Map CD/DVD option and click to select the Drive/Image File. Select the Custom Cisco ESXi ISO file downloaded from vmware.com and click Open. 4. Click the Map Device button on the Map CD/DVD pop-up to map the Custom Cisco ESXi ISO image. Install ESXi 5. Select Reset in the KVM console window to allow a power cycle and click OK 3 times. The boot process should now be visible on the KVM console window. 6. Alternatively, if the server is powered on, first shutdown the server, then boot the server by selecting Boot Server and clicking OK, then click OK again. To install ESXi, complete the following steps: 1. During boot, make sure the Nimble array is discovered this will confirm that the iscsi boot configuration done using Cisco UCSM was correct and that the array was discovered by the host at the iscsi level. A message such as the following should be seen. 92

93 2. At this point, the Nimble Storage web management interface should show the host as a connected initiator with the IQN of the host 3. During boot, the host also detects the presence of the ESXi installation media. Select the ESXi installer from the displayed menu. If it does not, hit F6 to enter Boot menu and select either of the two Nimble options. 4. After the installer is finished loading, press Enter to continue with the installation. 5. Read and accept the end-user license agreement (EULA). Press F11 to accept and continue. 6. Select the iscsi boot volume that was previously set up as the boot volume/installation disk for ESXi and press Enter to continue with the installation. 7. Select the appropriate keyboard layout and press Enter. 8. Enter and confirm the root password and press Enter. 93

94 9. The installer issues a warning that existing partitions will be removed from the volume. Press F11 to continue with the installation. 10. After the installation is completes, hitting Enter will reboot the server. The ISO may need to unmapped before reboot. Setup Management Network for ESXI Host To set up the management network for ESXi host, complete the following steps: 1. When the host comes up, press F2 on the KVM console to login using root and corresponding password. 2. Select the Configure the Management Network option and press Enter. 3. Select the VLAN option and press Enter. 4. Enter the in-band management VLAN ID: 12 and press Enter. 5. From the Configure Management Network menu, select IP Configuration and press Enter. 6. Select the Set Static IP Address and Network Configuration option by using the space bar. 7. Enter the IP address for managing the first ESXi host: Enter the subnet mask for the first ESXi host: Enter the default gateway for the first ESXi host: Press Enter to accept the changes to the IP configuration. 11. Select the IPv6 Configuration option and press Enter. 12. Using the spacebar, unselect Enable IPv6 (restart required) and press Enter. 13. Select the DNS Configuration option and press Enter. 14. Because the IP address is assigned manually, the DNS information must also be entered manually. 15. Enter the IP address of the primary DNS server. 16. Optional: Enter the IP address of the secondary DNS server. 17. Enter the fully qualified domain name (FQDN) for the first ESXi host. 18. Press Enter to accept the changes to the DNS configuration. 19. Press Esc to exit the Configure Management Network submenu. 20. Press Y to confirm the changes and restart the host. 21. The ESXi host reboots. After reboot, press F2 and log back in as root. 22. Select Test Management Network to verify the management network is set up correctly and press Enter. 23. Press Enter to run the test. 24. Press Enter to exit the window. 25. Press Esc to log out of the VMware console. 94

95 Post-ESXi Install-Setup This section covers the setup required once the ESXi host has come up using iscsi SAN boot. This configuration will need to be done from vcenter client (either directly to host or from vcenter UI). Setup required at this point are: Enable NTP on the hosts Networking Setup at VMware vsphere level Storage Adaptor Setup at VMware vsphere level Update drivers if needed Install Nimble Connection manager (NCM) and setup Verify Storage Configuration Post-NCM Install Enable NTP on hosts To enable NTP on the hosts, complete the following steps on each host using VMware vsphere client. 1. From each vsphere Client, select the host in the inventory. 2. Click the Configuration tab to enable configurations. 3. Click Time Configuration in the Software pane. 4. Click Properties at the upper right side of the window. 5. At the bottom of the Time Configuration dialog box, click Options. 6. In the NTP Daemon Options dialog box, complete the following steps: 7. Click NTP Settings in the left pane and click Add. 8. In the Add NTP Server dialog box, enter the NTP server IP and click OK. 9. In the NTP Daemon Options dialog box, select the Restart NTP Service to Apply Changes checkbox and click OK. 10. In the Time Configuration dialog box, complete the following steps: 11. Select the NTP Client Enabled checkbox and click OK. 12. Verify that the clock is now set to approximately the correct time. The NTP server time may vary slightly from the host time. Networking Setup at VMware vsphere Level Though two iscsi interfaces were configured at the Cisco UCSM level to leverage the redundant Cisco UCS FI connections, they do not carry over into VMware ESXi level once the host boots ups. To use the redundant iscsi connections, the following configuration is required at the vsphere level. Complete the following steps: 1. Use vsphere client to access the host, go to Configuration tab and select Networking. Only one iscsi interface will be seen after reboot (iscsibootpg) 95

96 2. Click on Properties for the iscsibootvswitch to see the default iscsi label (iscsibootpg) and MTU. 3. Change the default iscsi label to iscsi-a and MTU to

97 4. Change the MTU to 9000 on the virtual switch that iscsi-a is connected. 97

98 5. Add a second iscsi port (iscsi-b) by adding a new VMkernel port to a new vswitch (vswitch1). From the Configuration tab, select Networking and Add Networking 6. From the Add Network Wizard, select VMkernel for Connection Type, create a vsphere standard switch for Network Access, iscsi-b for Network label and IP address and mask for iscsi-b on host2. IP address and mask are allocated from the IQN IP Address range see Cisco UCSM for the IQN IP address assigned to this host. 7. Add a physical adapter for this new vswitch to use. Click Properties for vswitch1, select Network Adapters tab, click Add, select vmnic2 (or any unclaimed adapter), click Next twice and then click Finish. 98

99 8. Set the MTU for the newly created vswitch1 and iscsi-b to For vswitch1, click Properties, select Ports tab, select vswitch and change MTU. Repeat for iscsi-b. 9. The vsphere Networking configuration after the changes is as shown below. 99

100 VMware vsphere Storage Adapter Setup In this section, iscsi-a and iscsi-b interfaces are added and bound to the iscsi storage adapter. The iscsi discovery IPs are also configured but this at the VMware vsphere level. Previously this was done at the Cisco UCSM layer under Server tab > root > Server > Service Profile > iscsi Boot Parameters. To configure the Storage adapter setup, complete the following steps: 1. Use VMware vsphere client to access the host. Go to Configuration tab, select Storage Adapters and select vmhba32 in the Software Adapters section of the window. Go to the Details section of the same window and select Nimble iscsi Disk from the list and click Properties. 2. In the Properties Window, select Network Configuration tab, click Add. Select iscsi-a to bind this VMkernel port to the storage adapter. Repeat to add iscsi-b. 100

101 3. Say Yes to the Rescan of the Host Bus Adapter. Select Paths tab in the Details section and you should now see 2 paths. Note that only one path shows Active (I/O) but the setup in the next section will address that such that both paths will be active between the host and the Nimble array. 101

102 4. Add Discovery IPs to dynamically discover datastores that the host can use when they are deployed as volumes on the Nimble array. To configure the discovery IP, from the vsphere client, go to Configuration tab, select Storage Adapters, select iscsi Software Adapter (vmhab32), then select the Nimble disk from the Details section at the bottom and click on Properties. Under the Dynamic Discovery tab, click Add to add the iscsi discovery IPs for iscsi-a. Repeat add for iscsi-b. 102

103 5. Now go to Configuration tab > Storage > click on Datastores and Rescan All to discover datastores that have been deployed on Nimble. In this setup, a DS-Infra volume was pre-configured on Nimble array and made accessible by all hosts as a datastore for common infra drivers and files. This is now accessible from this newly deployed host. Update ESXi Host Drivers At the time of this setup, the recommended ENIC drivers per the Cisco UCS Hardware and Software Interoperability matrix was not part of the custom ESXi ISO so a separate manual process was done to upgrade these drivers. The necessary drivers are available from Support Download Software Select Server type (B-series/C-series) Unified Computing System (UCS) Drivers Select the driver bundle (.zip). Complete the following steps to install the driver. Additional information for updating drivers can be found by doing a search for Cisco UCS Driver Installation on 1. Extract the contents of the driver zip file, and identify the *.vib file. 2. Using VMware vsphere client, go to Configuration tab > Storage > Datastores, select datastore (For example: DS-Infra). DS-Infra datastore used in this setup was setup to be accessible by all hosts so that all hosts in the setup could use the datastore to update the drivers. Right-click and select Browse Datastore, then click on the Upload icon to upload the *.vib file to an ESXi host datastore. 103

104 3. Select host and right-click and select Enter Maintenance mode to put the host into Maintenance Mode. Click Yes to Confirm and OK to acknowledge the Warning. 4. Next SSH into the ESXi host and install the driver using the following commands: esxcli software vib list grep enic esxcli software vib update v /vmfs/volumes/ds-infra/enic_drivers/<driver> If you get an error saying, you can use the --no-sigoption to work around it. esxcli software vib update v /vmfs/volumes/ds-infra/enic_drivers/<driver> --no-sig-check 5. Reboot the host from vsphere client. Install Nimble Connection Manager (NCM) NCM is required to enable optimal configuration with Nimble array such as setting up multipathing correctly, queue depth, timeout values etc. To install the Nimble Connection Manager, complete the following steps: Download the appropriate NCM version for this array from Nimble Storage InfoSight website. Put the newly deployed host in maintenance mode from vsphere client/vcenter before installing NCM. Enable SSH (if not enabled already) on the host. This can be done via vsphere client or via KVM console into the host. From the KVM console, press F2 to Customize System/View Logs, select Troubleshooting Options and then Enable/Disable SSH will be available as an option. SSH into the hosts and execute the following command: esxcli software vib install -d Note that this command assumes the host can access the Nimble Storage InfoSight website. Alternatively, the image can be downloaded from another location within your site and positioned on the host. 104

105 5. Reboot host from VMware vsphere client and enable SSH (if needed) and log back into the host and verify that NCM is installed. The same command before reload would have returned any info. 6. Take the host out of maintenance mode and disable SSH if needed. Verify Storage Configuration Post-NCM Install In this section, the best practices implemented by installing NCM are verified. To verify the specific NCM changes, complete the following steps: 1. Use vsphere client to login to the host, select Configuration tab, and then Storage. Select one of the datastores listed and click on Properties in the Datastore Details window below. 105

106 2. Click Manage Paths and verify that the info shows all paths as being Active Active (I/O). 106

107 Deploying Infrastructure Services The procedures in this section provide detailed instructions for installing VMware vcenter 6.0 U1 for use in a SmartStack environment. If a centralized vcenter is being used in this deployment, it is not necessary to install the vcenter Appliance. Installing/upgrading VMware vcenter Server Appliance (VCSA) in 6.0 is significantly different from other releases and uses an ISO file. Please refer to Knowledge Base article for details installing VCSA 6.0. VMware vcenter 6.0 U1 To deploy VMware vcenter Server Appliance, first deploy a Windows VM using the steps in this section. Install and Setup Microsoft Windows Server 2012 R2 To install and setup Microsoft Windows Server 2012 R2, complete the following steps: 1. Use VMware vsphere client to log in to the host where the VM will be deployed. 2. From the VMware vsphere Client, choose the host in the inventory pane. 3. Right-click the host and choose New Virtual Machine. 4. Choose Custom and click Next. 5. Enter a name for the VM. Click Next. 6. Choose the datastore (DS-Infra) that the VM will use. Click Next. 7. Choose Virtual Machine Version: 8. Click Next. 8. Verify that the Windows option and the Microsoft Windows Server 2012 (64 Bit) version are selected. Click Next. 9. Choose two virtual sockets and one core per virtual socket. Click Next. 10. Choose 12GB of memory. Click Next. 11. Choose one network interface card (NIC). 12. For NIC 1, choose the Network (MGMT-PG) that the VM will be on, select VMXNET3 for the adapter and click on Enable at power-on box. Click Next. 13. Keep the LSI Logic SAS option for the SCSI controller Selected. Click Next. 14. Keep the Create a New Virtual Disk Option selected. Click Next. 15. Make the disk size at least 80GB and the default options. Click Next. 16. Click Next. 17. Check the edit the virtual machine setting before completion. Click Continue. 18. Window opens up. Click the Options tab. 107

108 19. Choose Boot Options. 20. Check the Force Bios Setup check box. 21. Click Finish. 22. From the left pane, expand the host field by clicking the plus sign (+). 23. Select the newly created SQL Server VM and click Open Console. 24. Click the third button (green right arrow) to power on the VM. 25. Click the ninth button (CD with a wrench) to map the Windows Server 2012 R2 ISO, and then choose Connect to ISO Image on Local Disk. 26. Navigate to Windows Server 2012 R2 ISO, select it, and click Open. 27. Right-click the newly created SQL Server VM and click Open Console. 28. In the BIOS Setup Utility window and use the right arrow key to navigate to the Boot menu. Use the down arrow key to choose CD-ROM Drive. Press the plus (+) key twice to move CD-ROM Drive to the top of the list. Press F10 and Enter to save the selection and exit the BIOS Setup Utility. 29. The Windows Installer boots. Choose the appropriate language, time and currency format and keyboard. Click Next. 30. Click Install Now. 31. Enter Product key to activate windows. Click Next. 32. Select the Windows 2012 R2 Standard (Server with a GUI) option. Click Next. 33. Read and accept the license terms and click Next. 34. Choose Custom: Install Windows only (advanced). Click Next. 35. Make sure that Disk0 Unallocated Space is selected. Click Next to allow the Windows installation to complete 36. After the Windows installation is complete and the VM has rebooted, Click OK to set the Administrator password. 37. Enter and confirm the Administrator password and click Finish. 38. After logging into the VM desktop, from the VM console window, choose the VM menu. Under Guest, choose Install/Upgrade VMware Tools. Click OK. 39. Click OK Installing the VMware tools package will greatly enhance graphics and mouse performance in your virtual machine. 40. If prompted to eject the Windows installation media before running the setup for the VMware tools, Click OK, then click OK. 41. A pop-up window shows on the VM console regarding D: drive, tap on the window and then choose Run setup64.exe. 42. In the VMware Tools installer window, click Next. 43. Make sure that Typical is selected and click Next. 44. Click Install. 45. Click Finish. 108

109 46. Click Yes to restart the VM. 47. After the reboot is complete, from top toolbar, select VM > Guest > Send Ctrl+Alt+Del and enter the password in the VM console window to login to the VM. 48. Set the time zone for the VM, IP address, gateway, and host name. Add the VM to the Windows AD domain. 49. Verify that Windows is activated, otherwise enter key and activate. 50. Log back into the VM and download and install all required Windows updates. Install and Setup VMware vcenter Server Appliance (VCSA) To install VMware vcenter Server Appliance, complete the following steps: Download the VMware vcenter Server Appliance installer ISO from VMware Web site at to your site. Using a vsphere client, Login (For example: root) to the host where the vcenter VM will be deployed In the vcenter Server VMware console, click the ninth button (CD with a wrench) to map the VCSA Installer ISO and choose Connect to ISO Image on Local Disk to mount the ISO. Navigate to the VMware vcenter Server Appliance (VMware-VCSA-all) ISO, select it, and click Open. Install the Client Integration Plug-In The Client Integration Plug-In must be installed before deploying the VCSA. Complete the following steps to install the plugin: On the Windows VM, double click on the pop-up to open D: drive and select the option to view the folders. In the software installer directory, navigate to the vcsa directory and double-click VMware- ClientIntegrationPlugin exe. The Client Integration Plug-in installation wizard appears. On the Welcome page, click Next. Read and accept the terms in the End-User License Agreement and click Next. (Optional) Change the default path to the Client Integration Plug-in installation folder, and click Next. On the Ready to Install the Plug-in page of the wizard, review the information and click Install. After the installation completes, click Finish. Install vcenter Server Appliance To install vcenter 6.0 on the vcenter Server VM, complete the following steps: 1. From the software installer directory, double-click vcsa-setup.html. 2. Wait up to three seconds for the browser to detect the Client Integration 3. Plug-in and allow the plug-in to run on the browser when prompted. 4. On the Home page, click Install to start the vcenter Server Appliance deployment wizard. 5. Read and accept the End User License Agreement, and click Next. 109

110 6. On the Connect to the target server screen, provide the IP address, username and password for the host on which you want to deploy the vcenter Server Appliance appliance, and click Next. 7. (Optional) Accept the certificate warning, if any, by clicking Yes. 8. On the Set up virtual machine screen, enter the vcenter Server Appliance name, set the password for the root user, and click Next. 9. In the Select deployment type screen, select Install vcenter Server with an embedded Platform Services Controller and click Next. 110

111 10. In the Setup Single Sign-on screen, create a new vcenter Single Sign-On domain, and click Next. 11. In the Select appliance size screen, select the size that matches your deployment, and click Next. 111

112 12. In the Select datastore screen, select the location for the VM configuration and virtual disks should be stored (DS-Infra), and click Next. 13. In the Configure database screen, select the database to use, and click Next. 14. In the Network Settings screen, provide the VLAN network, IP address, Mask, Gateway, DNS and NTP info the vcenter Appliance should use. Optionally, you can also enable SSH to the VM. Click Next. 112

113 15. In the Ready to complete screen, review the deployment settings for the vcenter Server Appliance, and click Finish to complete the deployment process. 16. Click Close to exit the wizard. 113

114 Log in to vsphere Web Client To log into the vsphere Web Client, complete the following steps: 1. Using a web browser, navigate to 2. Enter the username (administrator@vsphere.local) and associated password. Click Login. 3. Now you can do some basic setup of the VCSA using the web client vcenter Server Appliance Setup Install the Client Integration Plugin The Client Integration Plug-in provides access to a virtual machine's console in the vsphere Web Client, and provides access to other vsphere infrastructure features. This step is not necessary in this setup as this was already done in order to install the VCenter Server Appliance. vcenter Server Appliance Setup Join Active Directory Domain To setup the vcenter Server Appliance, complete the following steps: 1. Login in the VCSA using the vsphere Web client using administrator@vsphere.local account or another account 2. Before joining the Active Directory Domain, verify that the account (administrator@vsphere.local) used to log in to the vcenter instance is part of the Single Sign-on Administrators group. From the Navigator window, go to Administration > Single Sign-on > Users and Groups > Group Members. If the user is not a group member, add the user using the + icon below Group Members. 3. Now navigate to Administration > System Configuration > Nodes 4. Under Nodes, select a vcenter instance/node ( ) and go to Manage tab 5. Click on Settings and select Advanced > Active Directory. Click Join. Provide the domain and account info in the Join Active Directory window and click OK. 114

115 6. Right-click the Node instance ( ) and select Reboot to restart the vcenter instance. If the changes took effect, the Join button will be greyed out and the Leave button will become available. 7. Navigate to Administration > Single Sign-On > Configuration. 8. On the Identity Sources tab, click the + to add Identity Source. 9. Select Active Directory (Integrated Windows Authentication) and enter the identity source settings to join the Active Directory domain. Click OK. 115

116 10. You should now see the joined Active Directory domain (smartstack.local). vcenter Server Appliance Setup ESXi Dump Collector ESXi Dump Collector is installed by default in the vcenter Server Appliance but some setup is required as outlined in the next few steps. To setup the ESXi Dump Collector, complete the following steps: 116

117 1. From the vsphere Web Client Home page, navigate to Administration > System Configuration > Nodes and select a node/vcenter instance ( ) from the list. 2. Select the Related Objects tab to see the list of services running on the vcenter instance. Select the VMware vsphere ESXi Dump Collector from the list and right-click to Start the service. 3. Right-click the service again to Edit Startup Type to Automatic. 117

118 ESXi Dump Collector Setup - Host Side To setup the ESXi Dump Collector on the host side, complete the following steps: SSH into the host and login as root with associated password. Execute the following commands to enable coredump to Dump Collector. a. esxcli system coredump network set --interface-name vmk0 --server-ip server-port 6500 b. esxcli system coredump network set --enable true c. esxcli system coredump network check 3. Repeat for each host in the topology. Setup vcenter Center with a Datacenter, Cluster, DRS and HA To set up the vcenter Center, complete the following steps: 1. In the vsphere Web Client, navigate to the vcenter Inventory Lists > Resources > vcenter Servers. 2. Select the vcenter instance ( ). 3. Go to Actions in the toolbar and select New Datacenter from the drop-down. 4. Rename the datacenter (For example: SS-DC-1), and click OK. 118

119 5. Go to Actions in the toolbar and select New Cluster from the drop-down. 6. In the New Cluster window, provide a cluster name, enable DRS, vsphere HA and Host monitoring. If mixing Cisco UCS M3 or M4 series servers within a vcenter cluster, it is necessary to enable EVC mode. For more details on the EVC mode, refer to the Enhanced vmotion Compatibility (EVC) Processor documentation. 7. Click OK. 119

120 Select Virtual Machine Swap File Location To select a virtual machine swap file location, complete the following steps: 1. Select Related Objects tab for the datacenter (For example: SS-DC-1). 2. Select the newly created cluster from the list (For example: SS-Mgmt). 3. Double-click on the new cluster (For example: SS-Mgmt) and select General from Settings in the menu bar. 120

121 4. Click Edit to change the swap file location. 5. Click OK. Add Node to Cluster To add a node to a cluster, complete the following steps: 1. Select the newly created cluster in the left pane 2. Go to Actions in the menu bar and select Add Host from the pull-down menu. 3. In the Add Host window, in the Name and Location screen, provide the IP address of the host. 4. In the Name and Location screen, provide the root access credentials for the host. 5. Click Yes to accept the certificate. 6. In the Host summary screen, review the information and click Next. 7. Assign a license key to the host and click Next. 8. (Optional) In the Lockdown Mode screen, to enable/disable remote access for the administrator account after vcenter Server takes control of this host and click Next. 9. In the Resource pool screen, click Next. 121

122 10. In the Ready to complete screen, review the summary and click Finish. Add the AD Account to the Administrator Group To add the AD account to the administrator group, complete the following steps: 1. Log in to the vsphere Web Client as 2. From the home Location, navigate to >>Administration>>Single Sign-ON>>User and Groups>>. 3. In the right pane, select Groups tab. 4. Click Administrators on Group Name. 122

123 5. Click the + on Group Members. 6. Change the Domain to <<domain>>. 7. Highlight the Administrator and click Add. 123

The CVD program consists of systems and solutions designed, tested, and documented to facilitate faster, more reliable, and more predictable customer

The CVD program consists of systems and solutions designed, tested, and documented to facilitate faster, more reliable, and more predictable customer The CVD program consists of systems and solutions designed, tested, and documented to facilitate faster, more reliable, and more predictable customer deployments. For more information, visit: http://www.cisco.com/go/designzone.

More information

Release Notes for Cisco Small Business Pro ESW 500 Series Switches

Release Notes for Cisco Small Business Pro ESW 500 Series Switches Release Notes for Cisco Small Business Pro ESW 500 Series Switches October, 2009 These Release Notes describe the recommended practices and known issues that apply to the ESW 500 Series of Switches for

More information

Cisco WAAS Mobile User Guide

Cisco WAAS Mobile User Guide Cisco WAAS Mobile User Guide Software Version 3.5 April 2010 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS

More information

Cisco Unified Web and Interaction Manager Browser Settings Guide

Cisco Unified Web and  Interaction Manager Browser Settings Guide Cisco Unified Web and E-Mail Interaction Manager Browser Settings Guide For Unified Contact Center Enterprise and Hosted and Unified ICM Release 4.3(1) September 2009 Americas Headquarters Cisco Systems,

More information

Cisco Unified Web and Interaction Manager Browser Settings Guide

Cisco Unified Web and  Interaction Manager Browser Settings Guide Cisco Unified Web and E-Mail Interaction Manager Browser Settings Guide For Unified Contact Center Enterprise and Hosted and Unified ICM Release 4.2(5) October 2008 Americas Headquarters Cisco Systems,

More information

Cisco Video Surveillance Virtual Matrix Client Configuration Guide

Cisco Video Surveillance Virtual Matrix Client Configuration Guide Cisco Video Surveillance Virtual Matrix Client Configuration Guide Release 6.2 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408

More information

Maintenance Checklists for Microsoft Exchange on a Cisco Unity System

Maintenance Checklists for Microsoft Exchange on a Cisco Unity System Maintenance Checklists for Microsoft Exchange on a Cisco Unity System Published January 13, 2009 This document contains checklists for tasks required to ensure that the Cisco Unity system and Microsoft

More information

Using Microsoft Outlook to Schedule and Join Cisco Unified MeetingPlace Express Meetings

Using Microsoft Outlook to Schedule and Join Cisco Unified MeetingPlace Express Meetings Using Microsoft Outlook to Schedule and Join Cisco Unified MeetingPlace Express Meetings Cisco Unified MeetingPlace Express Release 2.x contains a plug-in that allows you to schedule, attend, and manage

More information

FlashStack Virtual Server Infrastructure with iscsi Storage for VMware vsphere 6.5 U1

FlashStack Virtual Server Infrastructure with iscsi Storage for VMware vsphere 6.5 U1 FlashStack Virtual Server Infrastructure with iscsi Storage for VMware vsphere 6.5 U1 iscsi Deployment Guide for FlashStack with Cisco UCS 6300 Fabric Interconnect and Pure Storage FlashArray//X70 Last

More information

FlashStack Virtual Server Infrastructure with Fibre Channel Storage for VMware vsphere 6.5 U1

FlashStack Virtual Server Infrastructure with Fibre Channel Storage for VMware vsphere 6.5 U1 FlashStack Virtual Server Infrastructure with Fibre Channel Storage for VMware vsphere 6.5 U1 Fibre Channel Deployment Guide for FlashStack with Cisco UCS 6300 Fabric Interconnect and Pure Storage FlashArray//X70

More information

Maintenance Checklists for Active Directory on a Cisco Unity System with Exchange as the Message Store

Maintenance Checklists for Active Directory on a Cisco Unity System with Exchange as the Message Store Maintenance Checklists for Active Directory on a Cisco Unity System with Exchange as the Message Store Published January 13, 2009 This document contains checklists for tasks required to ensure that the

More information

Cisco Unified Attendant Console Backup and Restore Guide

Cisco Unified Attendant Console Backup and Restore Guide Cisco Unified Attendant Console Backup and Restore Guide Revised: May 30, 2013, 2011, This document describes how to back up Cisco Unified Attendant Console server Version 9.1 (all Editions), and restore

More information

Cisco Software Licensing Information for Cisco Unified Communications 500 Series for Small Business

Cisco Software Licensing Information for Cisco Unified Communications 500 Series for Small Business Cisco Software Licensing Information for Cisco Unified Communications 500 Series for Small Business Feb. 06, 2008, This document describes the Cisco Software Licensing (CSL) information for the Cisco Unified

More information

Connecting Cisco 4-Port FXS/DID Voice Interface Cards

Connecting Cisco 4-Port FXS/DID Voice Interface Cards Connecting Cisco 4-Port FXS/DID Voice Interface Cards Revised: April 15, 2008, OL-15695-01 Overview This document provides an overview of Cisco interface cards and explains how to install the Cisco 4-port

More information

FlexPod Datacenter with IP-Based Storage using VMware vsphere 6.5 Update1, NetApp AFF A- Series, and Cisco UCS Manager 3.2

FlexPod Datacenter with IP-Based Storage using VMware vsphere 6.5 Update1, NetApp AFF A- Series, and Cisco UCS Manager 3.2 FlexPod Datacenter with IP-Based Storage using VMware vsphere 6.5 Update1, NetApp AFF A- Series, and Cisco UCS Manager 3.2 Deployment Guide for FlexPod Datacenter with IP-Based Storage using VMware vsphere

More information

FlexPod Datacenter with

FlexPod Datacenter with FlexPod Datacenter with Microsoft Hyper-V Windows Server 2016 Deployment Guide for FlexPod Datacenter with Microsoft Hyper-V Windows Server 2016 Last Updated: August 28, 2017 1 About the Cisco Validated

More information

Release Notes for SPA942 and SPA962 IP Phones Firmware Version 6.1.3

Release Notes for SPA942 and SPA962 IP Phones Firmware Version 6.1.3 Release Notes for SPA942 and SPA962 IP Phones Firmware Version 6.1.3 September 2008 These Release Notes describe the new features and enhancements in the SPA942 and SPA962 firmware version 6.1.3. Contents

More information

Connecting Cisco DSU/CSU High-Speed WAN Interface Cards

Connecting Cisco DSU/CSU High-Speed WAN Interface Cards Connecting Cisco DSU/CSU High-Speed WAN Interface Cards Revised: April 15, 2008, Overview This document describes Cisco serial and DSU/CSU high-speed WAN interface cards (HWICs) and how to connect them

More information

7825-I4, 7828-I4 Hard Disk Firmware Update

7825-I4, 7828-I4 Hard Disk Firmware Update 7825-I4, 7828-I4 Hard Disk Firmware Update October 6, 2010 Document Revision 2 A firmware solution for a hard disk drive issue on the MCS 7825-I4, and 7828-I4 models Contents This document discuss the

More information

RAID Controller Firmware Upgrade Instructions for the Cisco WAE-7341, 7371, and 674

RAID Controller Firmware Upgrade Instructions for the Cisco WAE-7341, 7371, and 674 RAID Controller Firmware Upgrade Instructions for the Cisco WAE-7341, 7371, and 674 Revised: September 15, 2008, This document describes how to upgrade the RAID controller firmware in a Cisco Wide Area

More information

Release Notes for SPA9000 Voice System

Release Notes for SPA9000 Voice System Release Notes for SPA9000 Voice System Firmware Version 6.1 September 2008 These Release Notes describe the new features and enhancements in the SPA9000 Voice System firmware release for SPA9000, SPA400,

More information

Release Notes for Cisco ONS MA Release 9.01

Release Notes for Cisco ONS MA Release 9.01 Release Notes for Cisco ONS 15310-MA Release 9.01 Revised: July 2009, Release notes contain the new features and enhancements for the Cisco ONS 15310-MA platform. For detailed information regarding features,

More information

Cisco Virtual Office End User Instructions for Cisco 1811 Router Set Up at Home or Small Office

Cisco Virtual Office End User Instructions for Cisco 1811 Router Set Up at Home or Small Office Cisco Virtual Office End User Instructions for Cisco 1811 Router Set Up at Home or Small Office Introduction This document describes the end-user instructions to deploy the Cisco Virtual Office (CVO) for

More information

Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5

Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5 Technical Marketing Solutions Guide Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5 Document Revision Date Revision Description (author) 5/16/2014 1. 0 Draft release (mmclaughlin)

More information

Release Notes for Cisco Video Surveillance Manager 4.1/6.1

Release Notes for Cisco Video Surveillance Manager 4.1/6.1 Release Notes for Cisco Video Surveillance Manager 4.1/6.1 February, 2009 These release notes provide important information for the following Cisco Video Surveillance Manager (Cisco VSM) products: Cisco

More information

Configuring the WIP310 Wireless-G IP Phone with the SPA9000 Voice System

Configuring the WIP310 Wireless-G IP Phone with the SPA9000 Voice System Configuring the WIP310 Wireless-G IP Phone with the SPA9000 Voice System Contents Introduction 2 Audience 2 Scope 2 Related Documents 3 Overview 3 2008 Cisco Systems, Inc. All rights reserved. This document

More information

ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES. Cisco Server and NetApp Storage Implementation

ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES. Cisco Server and NetApp Storage Implementation ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES I. Executive Summary Superior Court of California, County of Orange (Court) is in the process of conducting a large enterprise hardware refresh. This

More information

Configuring an Intermediate IP Multicast Helper Between Broadcast-Only Networks

Configuring an Intermediate IP Multicast Helper Between Broadcast-Only Networks Configuring an Intermediate IP Multicast Helper Between Broadcast-Only Networks First Published: February 11, 2008 Last Updated: February 11, 2008 When a multicast-capable internetwork is between two subnets

More information

Release Notes for Cisco ONS SDH Release 9.01

Release Notes for Cisco ONS SDH Release 9.01 Release Notes for Cisco ONS 15454 SDH Release 9.01 Revised: July 2009, Release notes contain the new features and enhancements for the Cisco ONS 15454 SDH platform. For detailed information regarding features,

More information

Release Notes for Cisco Unified Attendant Console Standard Release

Release Notes for Cisco Unified Attendant Console Standard Release Release Notes for Cisco Unified Attendant Console Standard Release 10.0.1.1208 First Published: January 9, 2014, 2011, These release notes describe the new features and caveats for Cisco Unified Attendant

More information

Protected URL Database

Protected URL Database Revised: October, 2008, Contents Managing URL Blacklists Using the SCE 1 Configuring User Authorization 2 How to specify a new owner of the sce-url-database 2 How to configure the sce-url-database write-protection

More information

PPPoE Agent Remote-ID and DSL Line Characteristics Enhancement

PPPoE Agent Remote-ID and DSL Line Characteristics Enhancement PPPoE Agent Remote-ID and DSL Line Characteristics Enhancement First Published: December 5, 2006 Revised: August 29, 2008 The PPPoE Agent Remote-ID and DSL Line Characteristics Enhancement feature provides

More information

FlexPod Datacenter with SolidFire All-Flash Array Add-On

FlexPod Datacenter with SolidFire All-Flash Array Add-On NetApp Verified Architecture FlexPod Datacenter with SolidFire All-Flash Array Add-On NVA Deployment Karthick Radhakrishnan, David Klem, NetApp April 2017 NVA-0027-DEPLOY Version 1.0 TABLE OF CONTENTS

More information

Cisco Unified Web and Interaction Manager Supervision Console User s Guide

Cisco Unified Web and  Interaction Manager Supervision Console User s Guide Cisco Unified Web and E-Mail Interaction Manager Supervision Console User s Guide For Unified Contact Center Enterprise and Hosted and Unified ICM Release 4.2(5) October 2008 Americas Headquarters Cisco

More information

User Guide for Microsoft Outlook Plug-in for Cisco Unified Videoconferencing Manager Release 7.1

User Guide for Microsoft Outlook Plug-in for Cisco Unified Videoconferencing Manager Release 7.1 User Guide for Microsoft Outlook Plug-in for Cisco Unified Videoconferencing Manager Release 7.1 March 2010 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com

More information

Cisco Nexus 4001I and 4005I Switch Module for IBM BladeCenter Getting Started Guide

Cisco Nexus 4001I and 4005I Switch Module for IBM BladeCenter Getting Started Guide Send feedback to nexus4k-docfeedback@cisco.com Cisco Nexus 4001I and 4005I Switch Module for IBM BladeCenter Getting Started Guide This document includes the following sections: Overview, page 1 Safety

More information

FlexPod Express with VMware vsphere 6.0: Small and Medium Configurations

FlexPod Express with VMware vsphere 6.0: Small and Medium Configurations NetApp Verified Architecture FlexPod Express with VMware vsphere 6.0: Small and Medium Configurations Authors: Karthick Radhakrishnan and Arvind Ramakrishnan, NetApp Reviewers: Jeffrey Fultz and Chris

More information

FlexPod Datacenter with VMware vsphere 6.5, NetApp AFF A-Series and Fibre Channel

FlexPod Datacenter with VMware vsphere 6.5, NetApp AFF A-Series and Fibre Channel FlexPod Datacenter with VMware vsphere 6.5, NetApp AFF A-Series and Fibre Channel Deployment Guide for FlexPod Datacenter with Fibre Channel SAN and VMware vsphere 6.5 and ONTAP 9.1 Last Updated: April

More information

RAID Battery Backup Unit Replacement and RAID Firmware Upgrade for Cisco Security MARS

RAID Battery Backup Unit Replacement and RAID Firmware Upgrade for Cisco Security MARS RAID Battery Backup Unit Replacement and RAID Firmware Upgrade for Cisco Security MARS Published: August 20, 2009 This document ships with the Cisco Security MARS RAID Controller Back-Up Battery Unit (BBU),

More information

UCS deployment guide for Nimble Storage

UCS deployment guide for Nimble Storage Summary This article is intended as a how to guide to allow for successful deployment of Nimble Storage iscsi connectivity to Cisco UCS. Nimble Storage / Cisco UCS connectivity checklist: 1) Determine

More information

Cisco Registered Envelope Recipient Guide

Cisco Registered Envelope Recipient Guide September 8, 2008 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 Text Part Number:

More information

Cisco Report Server Readme

Cisco Report Server Readme Cisco Report Server Readme For Cisco Network Planning Solution 2.1, Cisco Network Planning Solution Service Provider 2.1, and Cisco Application Analysis Solution 2.1 Release 2.1 Americas Headquarters Cisco

More information

ADMINISTRATION GUIDE Cisco Small Business

ADMINISTRATION GUIDE Cisco Small Business ADMINISTRATION GUIDE Cisco Small Business Cisco ProtectLink Endpoint 1.0 CCDE, CCENT, CCSI, Cisco Eos, Cisco HealthPresence, Cisco Ironport, the Cisco logo, Cisco Lumin, Cisco Nexus, Cisco Nurse Connect,

More information

Exclusive Configuration Change Access and Access Session Locking

Exclusive Configuration Change Access and Access Session Locking Exclusive Configuration Change Access and Access Session Locking First Published: February 28, 2005 Last Updated: May 4, 2009 Exclusive Configuration Change Access (also called the Configuration Lock feature)

More information

Cisco IP Phone Agent User Guide

Cisco IP Phone Agent User Guide CAD 7.6 for Cisco Unified Contact Center Enterprise Release 7.5 May 2010 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000

More information

Connecting Cisco WLAN Controller Enhanced Network Modules to the Network

Connecting Cisco WLAN Controller Enhanced Network Modules to the Network Connecting Cisco WLAN Controller Enhanced Network Modules to the Network Revised: May 1, 2008, OL-16632-01 This guide describes how to connect Cisco wireless LAN (WLAN) controller enhanced network modules

More information

Contextual Configuration Diff Utility

Contextual Configuration Diff Utility Contextual Configuration Diff Utility First Published: November 2003 Last Updated: May 2, 2008 The Contextual Configuration Diff Utility feature provides the ability to perform a line-by-line comparison

More information

Release Notes for Catalyst 6500 Series and Cisco 7600 Series Internet Router CEF720 Module ROMMON Software

Release Notes for Catalyst 6500 Series and Cisco 7600 Series Internet Router CEF720 Module ROMMON Software Release Notes for Catalyst 6500 Series and Cisco 7600 Series Internet Router CEF720 Module ROMMON Software Current Release: 12.2(18r)S1 May 28, 2004 This publication describes how to upgrade the ROMMON

More information

Behavioral Change for Buffer Recarving

Behavioral Change for Buffer Recarving Part Number: OL-18534-01 First Published: December 8, 2008 Table 1 Feature History Cisco IOS Release 12.0(32.03)S03, 12.0(32)S08, 12.0(32)SY04 12.0(32)SY07, 12.0(32)S06c 12.0(32)SY07, 12.0(32)S06c, and

More information

White Paper: Using Microsoft Windows Server 2003 with Cisco Unity 4.0(4)

White Paper: Using Microsoft Windows Server 2003 with Cisco Unity 4.0(4) White Paper: Using Microsoft Windows Server 2003 with Cisco Unity 4.0(4) Revised July 30, 2004 This white paper explains the differences between installing Cisco Unity version 4.0(4) on a server running

More information

Adding a Cisco Small Business 300 Series Switch to SBCS 2.0

Adding a Cisco Small Business 300 Series Switch to SBCS 2.0 SMART Designs Smart Business Communications Systems v2.0 Adding a Cisco Small Business 300 Series Switch to SBCS 2.0 Application Note September, 2010 Americas Headquarters Cisco Systems, Inc. 170 West

More information

Cisco BTS Softswitch Turkish ISUP Feature Module

Cisco BTS Softswitch Turkish ISUP Feature Module Cisco BTS 10200 Softswitch Turkish ISUP Feature Module Revised: July 31, 2008 This document describes the Turkish ISUP feature for of the Cisco BTS 10200 Softswitch and explains how to use this feature.

More information

Cisco VDS Service Broker Software Installation Guide for UCS Platforms

Cisco VDS Service Broker Software Installation Guide for UCS Platforms Cisco VDS Service Broker 1.0.1 Software Installation Guide for UCS Platforms Revised: May 2013 This document provides detailed instructions for installing the Cisco Videoscape Distribution Suite Service

More information

FlexPod Express with VMware vsphere 5.1u1 Implementation Guide

FlexPod Express with VMware vsphere 5.1u1 Implementation Guide Technical Report FlexPod Express with VMware vsphere 5.1u1 Implementation Guide Karthick Radhakrishnan, Arvind Ramakrishnan, Lindsey Street, NetApp Jeffrey Fultz, Cisco March 2014 TR-4261 TABLE OF CONTENTS

More information

Cisco Aironet Very Short 5-GHz Omnidirectional Antenna (AIR-ANT5135SDW-R)

Cisco Aironet Very Short 5-GHz Omnidirectional Antenna (AIR-ANT5135SDW-R) Cisco Aironet Very Short 5-GHz Omnidirectional Antenna (AIR-ANT5135SDW-R) This document outlines the specifications for the Cisco Aironet Very Short 5-GHz Omnidirectional Antenna (AIR-ANT5135SDW-R) and

More information

Modified LNS Dead-Cache Handling

Modified LNS Dead-Cache Handling First Published: Sept. 30, 2007 Last Updated: Aug. 28, 2008 The feature allows you to display and clear (restart) any Layer 2 Tunnel Protocol (L2TP) Network Server (LNS) entry in a dead-cache (DOWN) state.

More information

Cisco Service Control Service Security: Outgoing Spam Mitigation

Cisco Service Control Service Security: Outgoing Spam Mitigation CISCO SERVICE CONTROL SOLUTION GUIDE Cisco Service Control Service Security: Outgoing Spam Mitigation Solution Guide, Release 3.5.5 1 Introduction and Scope 2 Functionality Overview 3 Mass-Mailing Based

More information

FlexPod Express with VMware vsphere 6.0U2, NetApp E-Series, and Cisco UCS Mini

FlexPod Express with VMware vsphere 6.0U2, NetApp E-Series, and Cisco UCS Mini NetApp Verified Architecture FlexPod Express with VMware vsphere 6.0U2, NetApp E-Series, and Cisco UCS Mini NVA Design and Deployment Arvind Ramakrishnan, NetApp January 2017 NVA-0032 Version 1.0 Reviewed

More information

Cisco BTS Softswitch Site Preparation and Network Communications Requirements, Release 6.0. Safety and Compliance

Cisco BTS Softswitch Site Preparation and Network Communications Requirements, Release 6.0. Safety and Compliance Cisco BTS 10200 Softswitch Site Preparation and Network Communications Requirements, Release 6.0.x This document explains the requirements for site preparation and network communications. Use this document

More information

Installing the Cisco Nexus 1000V Software Using ISO or OVA Files

Installing the Cisco Nexus 1000V Software Using ISO or OVA Files Installing the Cisco Nexus 1000V Software Using ISO or OVA Files This chapter contains the following sections: Installing the VSM Software, page 1 Installing the VSM Software Installing the Software from

More information

Recovery Guide for Cisco Digital Media Suite 5.2 Appliances

Recovery Guide for Cisco Digital Media Suite 5.2 Appliances Recovery Guide for Cisco Digital Media Suite 5.2 Appliances May 3, 2010 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000

More information

Configuring ISG VRF Transfer (Cisco IOS Release 12.2(28)SB)

Configuring ISG VRF Transfer (Cisco IOS Release 12.2(28)SB) Configuring ISG VRF Transfer (Cisco IOS Release 12.2(28)SB) First Published: March 20, 2006 Last Updated: June 25, 2009 Intelligent Services Gateway (ISG) is a Cisco IOS software feature set that provides

More information

Cisco Nexus 1000V Installation and Upgrade Guide, Release 5.2(1)SV3(1.4)

Cisco Nexus 1000V Installation and Upgrade Guide, Release 5.2(1)SV3(1.4) Cisco Nexus 1000V Installation and Upgrade Guide, Release 5.2(1)SV3(1.4) First Published: April 17, 2015 Last Modified: August 27, 2015 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San

More information

Cisco Nexus Switch Configuration Guide for Dell SC Series SANs. Dell Storage Engineering August 2015

Cisco Nexus Switch Configuration Guide for Dell SC Series SANs. Dell Storage Engineering August 2015 Cisco Nexus 6001 Switch Configuration Guide for Dell SC Series SANs Dell Storage Engineering August 2015 Revisions Date August 2015 Description Initial release THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES

More information

Online Bank Secures Future Leadership

Online Bank Secures Future Leadership EXECUTIVE SUMMARY Customer Name ING Romania Industry Financial Services Location Romania Company Size 700 employees Challenge Provide customers with seamless access to online bank applications Accommodate

More information

Cisco PGW 2200 Softswitch Generic Call Tagging Feature Module

Cisco PGW 2200 Softswitch Generic Call Tagging Feature Module Cisco PGW 2200 Softswitch Feature Module Document Release History Publication Date August 28, 2009 Comments Initial release of document. Feature History Release Modification 9.8(1) S5P5 The feature was

More information

FlexPod Express with Microsoft Windows Server 2012 R2 Hyper-V: Large Configuration

FlexPod Express with Microsoft Windows Server 2012 R2 Hyper-V: Large Configuration NetApp Verified Architecture FlexPod Express with Microsoft Windows Server 2012 R2 Hyper-V: Large Configuration NVA Deployment Guide Karthick Radhakrishnan, Arvind Ramakrishnan, Glenn Sizemore, NetApp

More information

Release Notes for Cisco Broadband Access Center 3.5

Release Notes for Cisco Broadband Access Center 3.5 Release Notes for Cisco Broadband Access Center 3.5 Revised: June 15, 2009, These release notes describe new software features, bug fixes, and documentation for Cisco Broadband Access Center (Cisco BAC),

More information

Cisco Unified Web and Interaction Manager Supervision Console User s Guide

Cisco Unified Web and  Interaction Manager Supervision Console User s Guide Cisco Unified Web and E-Mail Interaction Manager Supervision Console User s Guide For Unified Contact Center Express Release 4.2(1) July 2007 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive

More information

Cisco Next Generation Enterprise WAN

Cisco Next Generation Enterprise WAN Deployment Guide Cisco Next Generation Enterprise WAN Regional WAN Remote Access VPN Deployment Guide September, 2011 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public

More information

vsphere Networking Update 1 ESXi 5.1 vcenter Server 5.1 vsphere 5.1 EN

vsphere Networking Update 1 ESXi 5.1 vcenter Server 5.1 vsphere 5.1 EN Update 1 ESXi 5.1 vcenter Server 5.1 vsphere 5.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check

More information

PPPoE Session Recovery After Reload

PPPoE Session Recovery After Reload If the PPP keepalive mechanism is disabled on a customer premises equipment (CPE) device, a PPP over Ethernet (PPPoE) session will hang indefinitely after an aggregation device reload. The PPPoE Session

More information

VPDN LNS Address Checking

VPDN LNS Address Checking First Published: Sept. 30, 2007 Last Updated: Aug. 28, 2008 The feature allows a Layer 2 Tunnel Protocol (L2TP) Access Concentrator (LAC), that is receiving data from an L2TP Network Server (LNS) to check

More information

1 Obtaining Cisco ANA NSA 1.0 Patch 1

1 Obtaining Cisco ANA NSA 1.0 Patch 1 Readme File for the Cisco ANA NSA 1.0 Patch 1 This readme file supports the release of Cisco Active Network Abstraction Network Service Activation (Cisco ANA NSA) 1.0, Patch 1. The patch is installed on

More information

FlexPod Datacenter with NetApp MetroCluster

FlexPod Datacenter with NetApp MetroCluster NetApp Verified Architecture FlexPod Datacenter with NetApp MetroCluster NVA Deployment Aaron Kirk and Arvind Ramakrishnan, NetApp August 2016 NVA-0030-DEPLOY Version 1.0 Reviewed by TABLE OF CONTENTS

More information

Cisco Smart Business Communications System Teleworker Set Up

Cisco Smart Business Communications System Teleworker Set Up Cisco Smart Business Communications System Teleworker Set Up The Cisco Smart Business Communications System is a unified communications solution for small businesses that provides voice, data, video, security,

More information

Cisco MDS 9000 Family NX-OS High Availability and Redundancy Configuration Guide

Cisco MDS 9000 Family NX-OS High Availability and Redundancy Configuration Guide Cisco MDS 9000 Family NX-OS High Availability and Redundancy Configuration Guide July 2009 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com

More information

NetApp HCI. Deployment Guide. Version July _A0

NetApp HCI. Deployment Guide. Version July _A0 NetApp HCI Deployment Guide Version 1.3.1 July 2018 215-13522_A0 doccomments@netapp.com Table of Contents 3 Contents Introduction... 5 NetApp HCI hardware overview... 7 Environmental requirements... 9

More information

BGP Enforce the First Autonomous System Path

BGP Enforce the First Autonomous System Path BGP Enforce the First Autonomous System Path The BGP Enforce the First Autonomous System Path feature is used to configure a Border Gateway Protocol (BGP) routing process to discard updates received from

More information

Getting Started with Cisco Configuration Assistant 1.8

Getting Started with Cisco Configuration Assistant 1.8 Getting Started with Cisco Configuration Assistant 1.8 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387)

More information

FlexPod Express with VMware vsphere 6.7 and NetApp AFF A220

FlexPod Express with VMware vsphere 6.7 and NetApp AFF A220 NetApp Verified Architecture FlexPod Express with VMware vsphere 6.7 and NetApp AFF A220 NVA Deployment Savita Kumari, NetApp October 2018 NVA-1123-DEPLOY Version 1.0 Reviewed by TABLE OF CONTENTS 1 Program

More information

Advanced Services. IPSec Configuration on IOS Platforms

Advanced Services. IPSec Configuration on IOS Platforms Advanced Services on IOS Platforms Corporate Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 526-4100

More information

Release Notes for Cisco Service Control Management Suite Collection Manager (SCMS CM) 3.1.6

Release Notes for Cisco Service Control Management Suite Collection Manager (SCMS CM) 3.1.6 Release s for Cisco Service Control Management Suite Collection Manager (SCMS CM) 3.1.6 Covers: SCMS CM 3.1.6, SCMS CM 3.1.5, SCMS CM 3.1.0 February 14, 2009 Introduction, page 1 Release SCMS CM 3.1.6,

More information

How to Deploy vcenter on the HX Data Platform

How to Deploy vcenter on the HX Data Platform First Published: 2016-07-11 Last Modified: 2019-01-08 vcenter on HyperFlex Cisco HX Data Platform deployment, including installation and cluster configuration and management, requires a vcenter server

More information

Release Notes for Cisco Unified Attendant Console Compact Edition Version

Release Notes for Cisco Unified Attendant Console Compact Edition Version Release Notes for Cisco Unified Attendant Console Compact Edition Version 8.6.4.1106 Revised: July 3, 2012, These release notes describe the new features and caveats for Cisco Unified Attendant Console

More information

Configuring LDAP. Finding Feature Information. Contents

Configuring LDAP. Finding Feature Information. Contents Configuring LDAP First Published: March 19, 2010 Last Updated: March 19, 2010 Lightweight Directory Access Protocol (LDAP) is integrated into Cisco IOS software as a AAA protocol alongside the existing

More information

Resilient Ethernet Protocol

Resilient Ethernet Protocol First Published: January 31, 2008 Last Updated: October 3, 2008 REP is a Cisco proprietary protocol that provides an alternative to Spanning Tree Protocol (STP); it provides a way to control network loops,

More information

Suppress BGP Advertisement for Inactive Routes

Suppress BGP Advertisement for Inactive Routes Suppress BGP Advertisement for Inactive Routes The Suppress BGP Advertisements for Inactive Routes features allows you to configure the suppression of advertisements for routes that are not installed in

More information

vsphere Networking Update 2 VMware vsphere 5.5 VMware ESXi 5.5 vcenter Server 5.5 EN

vsphere Networking Update 2 VMware vsphere 5.5 VMware ESXi 5.5 vcenter Server 5.5 EN Update 2 VMware vsphere 5.5 VMware ESXi 5.5 vcenter Server 5.5 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition.

More information

Cisco Business Edition 6000 Installation Guide, Release 10.0(1)

Cisco Business Edition 6000 Installation Guide, Release 10.0(1) First Published: January 15, 2014 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883

More information

Basic Configuration Installation Guide

Basic Configuration Installation Guide RecoverPoint for VMs 5.1 Basic Configuration Installation Guide P/N 302-003-975 REV 1 July 4, 2017 This document contains information on these topics: Revision History... 2 Overview... 3 Reference architecture...

More information

Release Notes for Cisco MDS 9000 Family Fabric Manager Release 4.1(3b)

Release Notes for Cisco MDS 9000 Family Fabric Manager Release 4.1(3b) Release Notes for Cisco MDS 9000 Family Fabric Manager Release 4.1(3b) Release Date: June 1, 2009 Part Number: This document describes the new features, limitations, and caveats for Cisco MDS 9000 Family

More information

Cisco Nexus 1100 Series Virtual Services Appliances

Cisco Nexus 1100 Series Virtual Services Appliances Deployment Guide Cisco Nexus 1100 Series Virtual Services Appliances Deployment Guide Version 1.0 June 2013 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.

More information

Per IP Subscriber DHCP Triggered RADIUS Accounting

Per IP Subscriber DHCP Triggered RADIUS Accounting Per IP Subscriber DHCP Triggered RADIUS First Published: February 19, 2007 Last Updated: February 19, 2007 The Per IP Subscriber DHCP Triggered RADIUS feature enables system administrators to track IP

More information

FlexPod Express with VMware vsphere 6.7U1 and NetApp AFF A220 with Direct- Attached IP-Based Storage

FlexPod Express with VMware vsphere 6.7U1 and NetApp AFF A220 with Direct- Attached IP-Based Storage NetApp Verified Architecture FlexPod Express with VMware vsphere 6.7U1 and NetApp AFF A220 with Direct- Attached IP-Based Storage NVA Deployment Sree Lakshmi Lanka, NetApp April 2019 NVA-1131-DEPLOY Version

More information

FlexPod Express with VMware vsphere 6.5 and FAS2600

FlexPod Express with VMware vsphere 6.5 and FAS2600 NetApp Verified Architecture FlexPod Express with VMware vsphere 6.5 and FAS2600 NVA Deployment Melissa Palmer, Lindsey Street, NetApp April 2017 NVA-1112-DEPLOY Version 1.0 Reviewed by Cisco Systems,

More information

Wireless-G IP Phone QUICK INSTALLATION GUIDE. Package Contents

Wireless-G IP Phone QUICK INSTALLATION GUIDE. Package Contents QUICK INSTALLATION GUIDE Wireless-G IP Phone Model: WIP310 Package Contents Handset Phone Charger Power Adapter Li-ion Battery USB Cable Quick Installation Guide Read Me First Card 1 Installation A. Insert

More information

Release Notes for Click to Call Release 7.x

Release Notes for Click to Call Release 7.x Revised: November 27, 2009 These release notes describe all versions of Click to Call Release 7.x. To access the latest software upgrades for all versions of Click to Call, go to http://www.cisco.com/kobayashi/sw-center/sw-voice.shtml

More information

Cisco ACI with Cisco AVS

Cisco ACI with Cisco AVS This chapter includes the following sections: Cisco AVS Overview, page 1 Cisco AVS Installation, page 6 Key Post-Installation Configuration Tasks for the Cisco AVS, page 43 Distributed Firewall, page 62

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING IMPLEMENTATION GUIDE EMC VSPEX END-USER COMPUTING Citrix XenDesktop 7.1 and VMware vsphere for up to 500 Virtual Desktops Enabled by EMC VNXe3200 and EMC Powered Backup EMC VSPEX Abstract This describes

More information