NC-SI 1.2 PCIe Functions Representation (Work-in-Progress) Version 0.3 September 19, 2017

Size: px
Start display at page:

Download "NC-SI 1.2 PCIe Functions Representation (Work-in-Progress) Version 0.3 September 19, 2017"

Transcription

1 NC-SI 1.2 PCIe Functions Representation (Work-in-Progress) Version 0.3 September 19, 2017

2 Disclaimer The information in this presentation represents a snapshot of work in progress within the DMTF. This information is subject to change without notice. The standard specifications remain the normative reference for all information. For additional information, see the Distributed Management Task Force (DMTF) website. 2

3 PCIe Functions in NC-SI 1.2 NC-SI 1.2 shall address the following associations of PCIe physical functions (PFs) with network ports No network port partitioning within a host, single host Single PF associated with each network port Single PCIe root complex No network port partitioning within a host, multiple hosts sharing a network port 1 PF per host associated with a network port Multiple PCIe root complexes, one per host Network port partitioning within a host, single host: Multiple PFs associated with a network port Network port partitioning within a host, multiple hosts sharing a network port: Multiple PFs per host associated with a network port A physical network port partitioned into multiple logical network ports relative to one or more hosts (PFs only) Multiple PFs within a single PCIe root complex, PFs are associated with the network port Multiple PCIe root complexes, 1 PF per PCIe root complex, each PF associated with the network port Multiple PCIe root complexes, multiple PFs per PCIe root complex, PFs associated with the network port A physical network port shared by multiple hosts shall support one or both BMC models below Single BMC per host Single shared BMC across all hosts Multiple PFs with multiple PCIe root complexes 1 PF/root complex as well as multiple PFs/root complex SR-IOV introduces another layer in hierarchy: VFs as children of PFs 3

4 PCIe Functions in NC-SI 1.2 NC-SI 1.2 shall have the following representation of PFs and VFs A PF associated with a specific NC-SI channel A VF associated with a specific NC-SI channel that its parent PF is associated with NC-SI 1.2 may have the following representation of PFs and VFs A PF associated with a package A VF associated with a package NC-SI 1.2 shall support AENs to address change in associations of PCIe functions to network ports (e.g. hot plug events) 4

5 PCIe Function Identifier in NC-SI 1.2 Not part of NC-SI control packet header Only used in commands targeted to PCIe functions First field in the NC-SI command packet payload What is the format for PCIe function id? Options: PCIe BDF format or HRBDF format or PCIe ARI format Recommendation: Use HRBDF format NC-SI 1.2 commands shall use PCIe function id to address a function A command targeted to a PCIe function can be either package command or channel command Function identifier shall be validated before the command execution Function to channel association shall be checked for channel cmd 5

6 Proposed NC-SI 1.2 Commands for PCIe Functions Query Device Capabilities (package level command) Response provides partitioning, multi-host, and SR-IOV capabilities This command should provide the maximum capabilities of the device Query Port Capabilities (channel level command) Response provides partitioning, multi-host, and SR-IOV capabilities This command should provide the maximum capabilities per port Get PF Information (channel command) No function identifier in the command Response provides identifiers of all PFs associated with the channel or package Get Associated VF Information (channel command) PF identifier is specified in the command packet payload Response provides identifiers of all VFs associated with a specific PF Response provides all VF identifiers on the channel or package (special case) This should include both maximum VFs available on the PF as well as number of VFs enabled by the host OS 6

7 Proposed NC-SI 1.2 Commands for PCIe Functions Get MAC Address (channel or package command) Response provides permanent or configured MAC address on the function Set MAC Address (channel command) MAC address/type (e.g. LAN) being configured is provided in cmd payload Successful response means MAC address of a specific type is configured 7

8 Proposed NC-SI 1.2 Commands for PCIe Functions Get Transmit Bandwidth (channel or package command) Response provides transmit bandwidth (min, max) of the function Set Transmit Bandwidth (channel command) Bandwidth (min, max) being configured is provided in command payload Successful response means transmit bandwidth is applied to that function The sum of bandwidth across all enabled PFs on a channel should add up to port bandwidth. Enabling and Disabling of PFs may change bandwidth allocation. Maximum bandwidth can be oversubscribed. For bandwidth allocation, there should be one common method specified. Options for bandwidth allocation: 1) bandwidth allocation across all PFs using weighted, absolute, and percentage of bandwidth, 2) bandwidth setting per PF followed by a commit operation for all BWs to take effect 8

9 Proposed NC-SI 1.2 Commands for PCIe Functions Get Function Statistics (channel or package command) Response provides packet statistics for the function Get Function Status (channel or package command) Response provides status (enabled/disabled, driver status, etc.) of the function Get Boot Configuration (channel or package command) Response provides boot config (e.g. iscsi boot params) for the function Set Boot Configuration (channel or package command) Boot configuration and parameters are provided in command pkt payload Successful response means boot configuration is applied to that function 9

10 Teaming Support Teaming support for multiple ports per function should be a 2.0 spec item. In the 1.2 version, functions should be mapped to a single channel, while in 2.0 functions can be mapped to multiple channels. In the 1.2 version, the PCIe function representation should not prevent adding teaming support in 2.0 version. 10

11 Get Version ID Command This command reports ID of a single function on a channel. For multiple functions, we need a mechanism to address multiple functions IDs on a channel. Proposal TBD in NC-SI 1.2 spec. 11

NC-SI 1.2 Topics- Work-In- Progress. Version 0.10 September 13, 2017

NC-SI 1.2 Topics- Work-In- Progress. Version 0.10 September 13, 2017 NC-SI 1.2 Topics- Work-In- Progress Version 0.10 September 13, 2017 Disclaimer The information in this presentation represents a snapshot of work in progress within the DMTF. This information is subject

More information

QL45xxx UEFI HII BIOS. 5/4/2016 Karl Erickson

QL45xxx UEFI HII BIOS. 5/4/2016 Karl Erickson QL45xxx UEFI HII BIOS 5/4/2016 Karl Erickson Agenda What is UEFI HII? How do you use it? DEMO! NOTE that the actual fields in the BIOS are subject to CHANGE. 3 What is UEFI HII? What is it? The Unified

More information

Multi-Host Sharing of NVMe Drives and GPUs Using PCIe Fabrics

Multi-Host Sharing of NVMe Drives and GPUs Using PCIe Fabrics Multi-Host Sharing of NVMe Drives and s Using PCIe Fabrics Vincent Haché Principal Applications Engineer, Microsemi Corporation Santa Clara, CA 1 Introduction Increase in use of s and NVM in DC System

More information

User s Guide. Setting Up NPAR with QLogic Control Suite, QConvergeConsole, or Comprehensive Configuration Management

User s Guide. Setting Up NPAR with QLogic Control Suite, QConvergeConsole, or Comprehensive Configuration Management User s Guide Setting Up NPAR with QLogic Control Suite, QConvergeConsole, or Comprehensive Configuration Management 3400 and 8400 Series Adapters Windows Operating Systems BC0154502-00 B User s Guide Setting

More information

COSC6376 Cloud Computing Lecture 15: IO Virtualization

COSC6376 Cloud Computing Lecture 15: IO Virtualization COSC6376 Cloud Computing Lecture 15: IO Virtualization Instructor: Weidong Shi (Larry), PhD Computer Science Department University of Houston IOV Outline PCI-E Sharing Terminology System Image 1 Virtual

More information

Configuring SR-IOV. Table of contents. with HP Virtual Connect and Microsoft Hyper-V. Technical white paper

Configuring SR-IOV. Table of contents. with HP Virtual Connect and Microsoft Hyper-V. Technical white paper Technical white paper Configuring SR-IOV with HP Virtual Connect and Microsoft Hyper-V Table of contents Abstract... 2 Overview... 2 SR-IOV... 2 Advantages and usage... 2 With Flex-10... 3 Setup... 4 Supported

More information

Proposed PLDM support over NC-SI RBT Commands (Work-In-Progress)

Proposed PLDM support over NC-SI RBT Commands (Work-In-Progress) Proposed PLDM support over NC-SI RBT Commands (Work-In-Progress) This document proposes new commands and AEN to be added into NC-SI standard, in order to include full support of PLDM using NC-SI commands

More information

PCI SR-IOV on FreeBSD. Ryan Stone

PCI SR-IOV on FreeBSD. Ryan Stone PCI SR-IOV on FreeBSD Ryan Stone rstone@freebsd.org Performing I/O from a VM I/O is through (para-)virtualized devices implemented in the hypervisor Additional load on host; less CPU available to guests

More information

Link Virtualization based on Xen

Link Virtualization based on Xen Link Virtualization based on Xen ShinHyoung Lee, Chuck Yoo shlee@os.korea.ac.kr, hxy@os.korea.ac.kr Sponsored by: & Contents Introduction Future Internet Virtual Network Link Virtualization Related Works

More information

All Roads Lead to Convergence

All Roads Lead to Convergence All Roads Lead to Convergence Greg Scherer VP, Server and Storage Strategy gscherer@broadcom.com Broadcom Corporation 2 Agenda The Trend Toward Convergence over Ethernet Reasons for Storage and Networking

More information

Emulex Universal Multichannel

Emulex Universal Multichannel Emulex Universal Multichannel Reference Manual Versions 11.2 UMC-OCA-RM112 Emulex Universal Multichannel Reference Manual Corporate Headquarters San Jose, CA Website www.broadcom.com Broadcom, the pulse

More information

Proposal for OCP NIC 3.0 Management Requirements. Rev 0.3 December 2017

Proposal for OCP NIC 3.0 Management Requirements. Rev 0.3 December 2017 Proposal for OCP NIC 3.0 Management Requirements Rev 0.3 December 2017 Disclaimer The information in this presentation represents a snapshot of work in progress within the DMTF. This information is subject

More information

PCI Express x8 Single Port SFP+ 10 Gigabit Server Adapter (Intel 82599ES Based) Single-Port 10 Gigabit SFP+ Ethernet Server Adapters Provide Ultimate

PCI Express x8 Single Port SFP+ 10 Gigabit Server Adapter (Intel 82599ES Based) Single-Port 10 Gigabit SFP+ Ethernet Server Adapters Provide Ultimate NIC-PCIE-1SFP+-PLU PCI Express x8 Single Port SFP+ 10 Gigabit Server Adapter (Intel 82599ES Based) Single-Port 10 Gigabit SFP+ Ethernet Server Adapters Provide Ultimate Flexibility and Scalability in Virtual

More information

Jeff Dodson / Avago Technologies

Jeff Dodson / Avago Technologies SNIA PRESENTATION Tutorial: TITLE PCIe GOES Shared HERE I/O Jeff Dodson / Avago Technologies SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA unless otherwise noted.

More information

Ron Emerick, Oracle Corporation

Ron Emerick, Oracle Corporation PCI Express PRESENTATION Virtualization TITLE GOES HERE Overview Ron Emerick, Oracle Corporation SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA unless otherwise noted.

More information

NVM Express 1.3 Delivering Continuous Innovation

NVM Express 1.3 Delivering Continuous Innovation Architected for Performance NVM Express 1.3 Delivering Continuous Innovation June 2017 Jonmichael Hands, Product Marketing Manager Intel, NVM Express Marketing Co-Chair View recorded webcast NVMe 1.3 -

More information

All product specifications are subject to change without notice.

All product specifications are subject to change without notice. MSI N3000 series is cost-benefit rackmount network security. Basing on Intel Xeon E3-1200 v3/v4/v5 series CPU and Xeon D-1500 series SoC which is to help enterprise to be flexibly applied to various network

More information

VIRTUALIZING SERVER CONNECTIVITY IN THE CLOUD

VIRTUALIZING SERVER CONNECTIVITY IN THE CLOUD VIRTUALIZING SERVER CONNECTIVITY IN THE CLOUD Truls Myklebust Director, Product Management Brocade Communications 2011 Brocade Communciations - All Rights Reserved 13 October 2011 THE ENTERPRISE IS GOING

More information

Single Root I/O Virtualization and Sharing Specification Revision 1.0. September 11, 2007

Single Root I/O Virtualization and Sharing Specification Revision 1.0. September 11, 2007 Single Root I/O Virtualization and Sharing Specification Revision 1.0 September 11, 2007 Revision Revision History Date 1.0 Initial release. 9/11/2007 PCI-SIG disclaims all warranties and liability for

More information

Xilinx Answer Virtex-7 FPGA Gen3 Integrated Block for PCI Express core SRIOV Example Design Simulation

Xilinx Answer Virtex-7 FPGA Gen3 Integrated Block for PCI Express core SRIOV Example Design Simulation Xilinx Answer 57342 Virtex-7 FPGA Gen3 Integrated Block for PCI Express core SRIOV Example Design Simulation Important Note: This downloadable PDF of an answer record is provided to enhance its usability

More information

Virtual Networks: For Storage and Data

Virtual Networks: For Storage and Data Virtual Networks: For Storage and Data or Untangling the Virtual Server Spaghetti Pile Howard Marks Chief Scientist hmarks@deepstorage.net Our Agenda Today s Virtual Server I/O problem Why Bandwidth alone

More information

Oracle Enterprise Manager Ops Center. Introduction. What You Will Need. Configure and Install Root Domains 12c Release 3 (

Oracle Enterprise Manager Ops Center. Introduction. What You Will Need. Configure and Install Root Domains 12c Release 3 ( Oracle Enterprise Manager Ops Center Configure and Install Root Domains 12c Release 3 (12.3.0.0.0) E60040-01 June 2015 This guide provides an end-to-end example for how to use Oracle Enterprise Manager

More information

YANG Device Profile for Redfish Network Management. Joe White, David Black, John Leung Distributed Management Task Force

YANG Device Profile for Redfish Network Management. Joe White, David Black, John Leung Distributed Management Task Force YANG Device Profile for Redfish Network Management Joe White, David Black, John Leung Distributed Management Task Force Disclaimer The information in this presentation represents a snapshot of work in

More information

ECS 152A Computer Networks Instructor: Liu. Name: Student ID #: Final Exam: March 17, 2005

ECS 152A Computer Networks Instructor: Liu. Name: Student ID #: Final Exam: March 17, 2005 ECS 152A Computer Networks Instructor: Liu Name: Student ID #: Final Exam: March 17, 2005 Duration: 120 Minutes 1. The exam is closed book. However, you may refer to one sheet of A4 paper (double sided)

More information

Intel Rapid Storage Technology (Intel RST) Production Version Release

Intel Rapid Storage Technology (Intel RST) Production Version Release Intel Rapid Storage Technology (Intel RST) 16.8.0.1000 Production Version Release 12 December 2018 DISCLAIMER: Information in this document is provided in connection with Intel products. No license, express

More information

Cavium FastLinQ 25GbE Intelligent Ethernet Adapters vs. Mellanox Adapters

Cavium FastLinQ 25GbE Intelligent Ethernet Adapters vs. Mellanox Adapters Cavium FastLinQ 25GbE Intelligent Ethernet Adapters vs. Mellanox Adapters Cavium FastLinQ QL45000 25GbE adapters provide maximum performance and flexible bandwidth management to optimize virtualized servers

More information

Virtual Bridging considerations from Server perspective

Virtual Bridging considerations from Server perspective Virtual Bridging considerations from Server perspective Ilango Ganga Jan 15, 2009 1 Outline Server Virtualization concepts Virtual Ethernet Bridging evolution Server based Emulated Virtual Bridging in

More information

Network Adapters. FS Network adapter are designed for data center, and provides flexible and scalable I/O solutions. 10G/25G/40G Ethernet Adapters

Network Adapters. FS Network adapter are designed for data center, and provides flexible and scalable I/O solutions. 10G/25G/40G Ethernet Adapters Network Adapters IDEAL FOR DATACENTER, ENTERPRISE & ISP NETWORK SOLUTIONS FS Network adapter are designed for data center, and provides flexible and scalable I/O solutions. 10G/25G/40G Ethernet Adapters

More information

Red Hat Virtualization 4.1 Hardware Considerations for Implementing SR-IOV

Red Hat Virtualization 4.1 Hardware Considerations for Implementing SR-IOV Red Hat Virtualization 4.1 Hardware Considerations for Implementing SR-IOV Hardware considerations for implementing SR-IOV with Red Hat Virtualization Red Hat Virtualization Documentation TeamRed Hat Red

More information

Red Hat Enterprise Virtualization 3.6

Red Hat Enterprise Virtualization 3.6 Red Hat Enterprise Virtualization 3.6 Hardware Considerations for Implementing SR-IOV Hardware considerations for implementing SR-IOV with Red Hat Enterprise Virtualization Last Updated: 2017-09-27 Red

More information

Storage Protocol Offload for Virtualized Environments Session 301-F

Storage Protocol Offload for Virtualized Environments Session 301-F Storage Protocol Offload for Virtualized Environments Session 301-F Dennis Martin, President August 2016 1 Agenda About Demartek Offloads I/O Virtualization Concepts RDMA Concepts Overlay Networks and

More information

Management Component Transport Protocol (MCTP) PCIe VDM Transport Binding Specification

Management Component Transport Protocol (MCTP) PCIe VDM Transport Binding Specification 1 2 3 4 Document Identifier: Date: 2018-11-29 Version: 1.1.0 5 6 7 Management Component Transport Protocol (MCTP) PCIe VDM Transport Binding Specification 8 9 10 11 Supersedes: 1.0.2 Document Class: Normative

More information

QLOGIC SRIOV Fuel Plugin Documentation

QLOGIC SRIOV Fuel Plugin Documentation QLOGIC SRIOV Fuel Plugin Documentation Release 1.0-1.0.0-1 QLOGIC Jul 19, 2016 CONTENTS 1 Overview of the QLogic SRIOV Fuel Plugin 1 1.1 Software Prerequisites..........................................

More information

Enhancing pass through device support with IOMMU. Haitao Shan Yunhong Jiang Allen M Kay Eddie (Yaozu) Dong

Enhancing pass through device support with IOMMU. Haitao Shan Yunhong Jiang Allen M Kay Eddie (Yaozu) Dong Enhancing pass through device support with IOMMU Haitao Shan (haitao.shan@intel.com) Yunhong Jiang Allen M Kay Eddie (Yaozu) Dong Agenda Current Status Further enhancement Hardening host Improving functionality

More information

How to abstract hardware acceleration device in cloud environment. Maciej Grochowski Intel DCG Ireland

How to abstract hardware acceleration device in cloud environment. Maciej Grochowski Intel DCG Ireland How to abstract hardware acceleration device in cloud environment Maciej Grochowski Intel DCG Ireland Outline Introduction to Hardware Accelerators Intel QuickAssist Technology (Intel QAT) as example of

More information

Lecture 9 The Data Link Layer part II. Antonio Cianfrani DIET Department Networking Group netlab.uniroma1.it

Lecture 9 The Data Link Layer part II. Antonio Cianfrani DIET Department Networking Group netlab.uniroma1.it Lecture 9 The Data Link Layer part II Antonio Cianfrani DIET Department Networking Group netlab.uniroma1.it Physical Addresses Physical (or LAN or MAC) address: 48 bit string Hexadecimal representation

More information

Hardware-Assisted Mediated Pass-Through with VFIO. Kevin Tian Principal Engineer, Intel

Hardware-Assisted Mediated Pass-Through with VFIO. Kevin Tian Principal Engineer, Intel Hardware-Assisted Mediated Pass-Through with VFIO Kevin Tian Principal Engineer, Intel 1 Legal Disclaimer No license (express or implied, by estoppel or otherwise) to any intellectual property rights is

More information

Cisco UCS Virtual Interface Card 1225

Cisco UCS Virtual Interface Card 1225 Data Sheet Cisco UCS Virtual Interface Card 1225 Cisco Unified Computing System Overview The Cisco Unified Computing System (Cisco UCS ) is a next-generation data center platform that unites compute, networking,

More information

Security Proposal for PMCI Standards and Protocols Architecture for Version 1.0 Release Work in Progress Last Updated: 12/17/2018

Security Proposal for PMCI Standards and Protocols Architecture for Version 1.0 Release Work in Progress Last Updated: 12/17/2018 Security Proposal for PMCI Standards and Protocols Architecture for Version 1.0 Release Work in Progress Last Updated: 12/17/2018 Copyright 2018 DMTF Disclaimer The information in this presentation represents

More information

PAC485 Managing Datacenter Resources Using the VirtualCenter Distributed Resource Scheduler

PAC485 Managing Datacenter Resources Using the VirtualCenter Distributed Resource Scheduler PAC485 Managing Datacenter Resources Using the VirtualCenter Distributed Resource Scheduler Carl Waldspurger Principal Engineer, R&D This presentation may contain VMware confidential information. Copyright

More information

PCI Express x8 Quad Port 10Gigabit Server Adapter (Intel XL710 Based)

PCI Express x8 Quad Port 10Gigabit Server Adapter (Intel XL710 Based) NIC-PCIE-4SFP+-PLU PCI Express x8 Quad Port 10Gigabit Server Adapter (Intel XL710 Based) Key Features Quad-port 10 GbE adapters PCI Express* (PCIe) 3.0, x8 Exceptional Low Power Adapters Network Virtualization

More information

Virtual Data Center (vdc) Manual

Virtual Data Center (vdc) Manual Virtual Data Center (vdc) Manual English Version 1.0 Page 1 of 43 Content 1 HOW TO USE CLOUD PORTAL (VMWARE VIRTUAL DATA CENTER)... 3 2 VMWARE SYSTEM DETAILS... 5 3 HOW TO MANAGE VIRTUAL MACHINE... 6 Edit

More information

PLUSOPTIC NIC-PCIE-2SFP+-V2-PLU

PLUSOPTIC NIC-PCIE-2SFP+-V2-PLU PLUSOPTIC NIC-PCIE-2SFP+-V2-PLU PCI Express v3.0 x8 Dual Port SFP+ 10 Gigabit Server Adapter (Intel X710- BM2 Based) Overview: NIC-PCIE-2SFP+-V2-PLU is PLUSOPTIC a new generation of high-performance server

More information

MxGPU Setup Guide with VMware

MxGPU Setup Guide with VMware Page 1 of 17 MxGPU Setup Guide with VMware 1 Page 2 of 17 DISCLAIMER The information contained herein is for informational purposes only, and is subject to change without notice. While every precaution

More information

DMTF Management Initiatives for Academics

DMTF Management Initiatives for Academics DMTF Management Initiatives for Academics Jeff Hilland VP of Technology, DMTF 1 Agenda DMTF Management Initiatives SMASH DASH CDM Additional DMTF Standardization Protocols, Profiles, Generic Operations,

More information

OCP3. 0. ConnectX Ethernet Adapter Cards for OCP Spec 3.0

OCP3. 0. ConnectX Ethernet Adapter Cards for OCP Spec 3.0 OCP3. 0 ConnectX Ethernet Adapter Cards for OCP Spec 3.0 High Performance 10/25/40/50/100/200 GbE Ethernet Adapter Cards in the Open Compute Project Spec 3.0 Form Factor For illustration only. Actual products

More information

for ExpressCard Adapter for CompactFlash Type I / II (PCI-e interface)

for ExpressCard Adapter for CompactFlash Type I / II (PCI-e interface) for ExpressCard Adapter for CompactFlash Type I / II (PCI-e interface) 1 Table of Content Section A : User Manual Page A.1 Features 3 A.2 How to use 4 2.1 Recommended mode of operation : Fast Removal mode

More information

Cisco UCS Virtual Interface Card 1227

Cisco UCS Virtual Interface Card 1227 Data Sheet Cisco UCS Virtual Interface Card 1227 Cisco Unified Computing System Overview The Cisco Unified Computing System (Cisco UCS ) is a next-generation data center platform that unites computing,

More information

Network Controller Sideband Interface (NC-SI) Specification

Network Controller Sideband Interface (NC-SI) Specification 1 2 3 4 Document Identifier: Date: 2015-09-23 Version: 1.1.0 5 6 Network Controller Sideband Interface (NC-SI) Specification 7 8 9 10 Supersedes: 1.0.1 Document Class: Normative Document Status: Published

More information

Mellanox ConnectX-4 NATIVE ESXi Driver for VMware vsphere 5.5/6.0 Release Notes. Rev /

Mellanox ConnectX-4 NATIVE ESXi Driver for VMware vsphere 5.5/6.0 Release Notes. Rev / Mellanox ConnectX-4 NATIVE ESXi Driver for VMware vsphere 5.5/6.0 Release Notes Rev 4.15.6.22/4.5.6.22 www.mellanox.com Mellanox Technologies NOTE: THIS HARDWARE, SOFTWARE OR TEST SUITE PRODUCT ( PRODUCT(S)

More information

WinOF-2 Release Notes

WinOF-2 Release Notes WinOF-2 Release Notes www.mellanox.com NOTE: THIS HARDWARE, SOFTWARE OR TEST SUITE PRODUCT ( PRODUCT(S) ) AND ITS RELATED DOCUMENTATION ARE PROVIDED BY MELLANOX TECHNOLOGIES AS-IS WITH ALL FAULTS OF ANY

More information

Uniform Resource Locators (URL)

Uniform Resource Locators (URL) The World Wide Web Web Web site consists of simply of pages of text and images A web pages are render by a web browser Retrieving a webpage online: Client open a web browser on the local machine The web

More information

Internetworking Part 1

Internetworking Part 1 CMPE 344 Computer Networks Spring 2012 Internetworking Part 1 Reading: Peterson and Davie, 3.1 22/03/2012 1 Not all networks are directly connected Limit to how many hosts can be attached Point-to-point:

More information

NC-SI over MCTP Binding Specification

NC-SI over MCTP Binding Specification 1 2 3 4 Document Number: DSP0261 Date: 2015-03-21 Version: 1.1.0 5 6 7 8 9 10 11 Supersedes: 1.0.0 Document Type: Specification Document Class: Normative Document Status: Published Document Language: en-us

More information

Oracle Enterprise Manager Ops Center

Oracle Enterprise Manager Ops Center Oracle Enterprise Manager Ops Center Configure and Install Guest Domains 12c Release 3 (12.3.2.0.0) E60042-03 June 2016 This guide provides an end-to-end example for how to use Oracle Enterprise Manager

More information

LPC 2013 PCI Microconference

LPC 2013 PCI Microconference LPC 2013 PCI Microconference SR IOV Virtual Function Lifetimes Discussion of issues around enabling, disabling, and removing Virtual Functions PCIe SR IOV Extended Capability Structure % lspci s02:00.0

More information

PCI-SIG ENGINEERING CHANGE NOTICE

PCI-SIG ENGINEERING CHANGE NOTICE PCI-SIG ENGINEERING CHANGE NOTICE TITLE: Hierarchy ID Message DATE: Introduced: Feb 23, 216 Updated: Sept 8, 216 14-day Cross WG Review: Sept 15, 216 Member Review: October 2, 216 Final Approval: February

More information

QuickSpecs. HP Z 10GbE Dual Port Module. Models

QuickSpecs. HP Z 10GbE Dual Port Module. Models Overview Models Part Number: 1Ql49AA Introduction The is a 10GBASE-T adapter utilizing the Intel X722 MAC and X557-AT2 PHY pairing to deliver full line-rate performance, utilizing CAT 6A UTP cabling (or

More information

ALLNET ALL0141-4SFP+-10G / PCIe 10GB Quad SFP+ Fiber Card Server

ALLNET ALL0141-4SFP+-10G / PCIe 10GB Quad SFP+ Fiber Card Server ALLNET ALL0141-4SFP+-10G / PCIe 10GB Quad SFP+ Fiber Card Server EAN CODE 4 0 3 8 8 1 6 0 6 9 1 2 2 Highlights: Quad-port 10GbE SFP+ server adapters PCI Express (PCIe) v3.0, 8.0 GT/s, x8 lanes SFP+ Connectivity

More information

Summary of MAC protocols

Summary of MAC protocols Summary of MAC protocols What do you do with a shared media? Channel Partitioning, by time, frequency or code Time Division, Code Division, Frequency Division Random partitioning (dynamic) ALOHA, S-ALOHA,

More information

Lenovo XClarity Administrator Quick Start Guide Configuring Servers Using Lenovo XClarity Administrator

Lenovo XClarity Administrator Quick Start Guide Configuring Servers Using Lenovo XClarity Administrator Lenovo XClarity Administrator Quick Start Guide Configuring Servers Using Lenovo XClarity Administrator Version 2.3.0 Note Before using this information and the product it supports, read the general and

More information

Quality of Service Commands

Quality of Service Commands Quality of Service Commands This module lists quality of service (QoS) commands in alphabetical order. To use commands of this module, you must be in a user group associated with a task group that includes

More information

Dell EMC Unity Family

Dell EMC Unity Family Dell EMC Unity Family Version 4.4 Configuring and managing LUNs H16814 02 Copyright 2018 Dell Inc. or its subsidiaries. All rights reserved. Published June 2018 Dell believes the information in this publication

More information

Defining QoS for Multiple Policy Levels

Defining QoS for Multiple Policy Levels CHAPTER 13 In releases prior to Cisco IOS Release 12.0(22)S, you can specify QoS behavior at only one level. For example, to shape two outbound queues of an interface, you must configure each queue separately,

More information

Intel Solid State Drive Client PCIe* Microsoft* Windows* Driver

Intel Solid State Drive Client PCIe* Microsoft* Windows* Driver Intel Solid State Drive Client PCIe* Microsoft* Windows* Driver Software 4.2.0.1002 Number: 331995-006US Intel may make changes to specifications and product descriptions at any time, without notice. Designers

More information

<Insert Picture Here> LDoms Deep Dive IO Best Practices for Oracle VM Server for SPARC

<Insert Picture Here> LDoms Deep Dive IO Best Practices for Oracle VM Server for SPARC LDoms Deep Dive IO Best Practices for Oracle VM Server for SPARC Stefan Hinker EMEA Hardware Principal Sales Consultant The following is intended to outline our general product direction.

More information

Smart Call Home Portal Web Application

Smart Call Home Portal Web Application CHAPTER 3 Revised: July 10, 2014, The Smart Call Home web application provides access to: An overview page with quick links to key Smart Call Home functions and documentation. Most of the quick links are

More information

IP/MAC Address Translation

IP/MAC Address Translation IP/MAC Address Translation -Go over quiz answers -ARP -DHCP -NAT Today Transition from Network to Datalink How do we get datagrams to the right physical host? Tricky part comes when a router is forwarding

More information

PCI-SIG ENGINEERING CHANGE REQUEST

PCI-SIG ENGINEERING CHANGE REQUEST PCI-SIG ENGINEERING CHANGE REQUEST TITLE: ACPI additions for ASPM, OBFF, LTR ECNs DATE: October 30, 2009 Updated February 1, 2010 AFFECTED DOCUMENT: PCI Firmware Spec 3.0 SPONSOR: Intel Corporation Part

More information

NEC Express5800/B120f-h System Configuration Guide

NEC Express5800/B120f-h System Configuration Guide NEC Express5800/B120f-h System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

vsphere Networking Update 1 ESXi 5.1 vcenter Server 5.1 vsphere 5.1 EN

vsphere Networking Update 1 ESXi 5.1 vcenter Server 5.1 vsphere 5.1 EN Update 1 ESXi 5.1 vcenter Server 5.1 vsphere 5.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check

More information

Multi-Level Priority Queues

Multi-Level Priority Queues The (MPQ) feature allows you to configure multiple priority queues for multiple traffic classes by specifying a different priority level for each of the traffic classes in a single service policy map.

More information

Video Command Reference

Video Command Reference Video CLI Tree Video Command Reference This section provides a command reference for the CLI commands for IP-TV video applications Topics include: IP-TV Command Hierarchies on page 676 Hardware Commands

More information

RDMA on vsphere: Update and Future Directions

RDMA on vsphere: Update and Future Directions RDMA on vsphere: Update and Future Directions Bhavesh Davda & Josh Simons Office of the CTO, VMware 3/26/2012 1 2010 VMware Inc. All rights reserved Agenda Guest-level InfiniBand preliminary results Virtual

More information

Medium Access Protocols

Medium Access Protocols Medium Access Protocols Summary of MAC protocols What do you do with a shared media? Channel Partitioning, by time, frequency or code Time Division,Code Division, Frequency Division Random partitioning

More information

CompSci 356: Computer Network Architectures. Lecture 7: Switching technologies Chapter 3.1. Xiaowei Yang

CompSci 356: Computer Network Architectures. Lecture 7: Switching technologies Chapter 3.1. Xiaowei Yang CompSci 356: Computer Network Architectures Lecture 7: Switching technologies Chapter 3.1 Xiaowei Yang xwy@cs.duke.edu Types of switching Datagram Virtual circuit Source routing Today Bridges and LAN switches

More information

Intel Solid State Drive Client PCIe* Microsoft* Windows* Driver

Intel Solid State Drive Client PCIe* Microsoft* Windows* Driver Intel Solid State Drive Client PCIe* Microsoft* Windows* Driver Software 3.2.0.1002 Number: 331995-006US Intel may make changes to specifications and product descriptions at any time, without notice. Designers

More information

VMware vsphere Administration Training. Course Content

VMware vsphere Administration Training. Course Content VMware vsphere Administration Training Course Content Course Duration : 20 Days Class Duration : 3 hours per day (Including LAB Practical) Fast Track Course Duration : 10 Days Class Duration : 8 hours

More information

Ethernet. High-Performance Ethernet Adapter Cards

Ethernet. High-Performance Ethernet Adapter Cards High-Performance Ethernet Adapter Cards Supporting Virtualization, Overlay Networks, CPU Offloads and RDMA over Converged Ethernet (RoCE), and Enabling Data Center Efficiency and Scalability Ethernet Mellanox

More information

NEC Express5800/B110d Configuration Guide

NEC Express5800/B110d Configuration Guide NEC Express5800/B110d Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper

More information

Single and Dual Transit Buffer Interactions

Single and Dual Transit Buffer Interactions Single and Dual Transit Buffer Interactions Necdet Uzun and Carey Kloss Goals Standard shall allow single and dual transit path implementations Same fairness algorithm shall be used for both Nodes should

More information

Huawei MZ510 NIC V100R001. White Paper. Issue 09 Date HUAWEI TECHNOLOGIES CO., LTD.

Huawei MZ510 NIC V100R001. White Paper. Issue 09 Date HUAWEI TECHNOLOGIES CO., LTD. V100R001 Issue 09 Date 2016-11-21 HUAWEI TECHNOLOGIES CO., LTD. 2016. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent

More information

Intel Solid State Drive Datacenter PCIe* Microsoft* Windows* Driver

Intel Solid State Drive Datacenter PCIe* Microsoft* Windows* Driver Intel Solid State Drive Datacenter PCIe* Microsoft* Windows* Driver Software 4.2.0.1002 Number: 331995-006US Intel may make changes to specifications and product descriptions at any time, without notice.

More information

A Principled Technologies deployment guide commissioned by QLogic Corporation

A Principled Technologies deployment guide commissioned by QLogic Corporation A Principled Technologies deployment guide commissioned by QLogic Corporation Table of contents Executive summary... 2 Introduction... 2 QLogic QConvergeConsole... 3 Overview of the procedure... 4 Initial

More information

Configuring Repeater and Standby Access Points and Workgroup Bridge Mode

Configuring Repeater and Standby Access Points and Workgroup Bridge Mode 20 CHAPTER Configuring Repeater and Standby Access Points and Workgroup Bridge Mode This chapter describes how to configure your access point as a repeater, as a hot standby unit, or as a workgroup bridge.

More information

Principles behind data link layer services:

Principles behind data link layer services: Data link layer Goals: Principles behind data link layer services: Error detection, correction Sharing a broadcast channel: Multiple access Link layer addressing Reliable data transfer, flow control Example

More information

Principles behind data link layer services:

Principles behind data link layer services: Data link layer Goals: Principles behind data link layer services: Error detection, correction Sharing a broadcast channel: Multiple access Link layer addressing Reliable data transfer, flow control Example

More information

Interrupt Swizzling Solution for Intel 5000 Chipset Series based Platforms

Interrupt Swizzling Solution for Intel 5000 Chipset Series based Platforms Interrupt Swizzling Solution for Intel 5000 Chipset Series based Platforms Application Note August 2006 Document Number: 314337-002 Notice: This document contains information on products in the design

More information

vsphere Networking Update 2 VMware vsphere 5.5 VMware ESXi 5.5 vcenter Server 5.5 EN

vsphere Networking Update 2 VMware vsphere 5.5 VMware ESXi 5.5 vcenter Server 5.5 EN Update 2 VMware vsphere 5.5 VMware ESXi 5.5 vcenter Server 5.5 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition.

More information

Xilinx Answer QDMA DPDK User Guide

Xilinx Answer QDMA DPDK User Guide Xilinx Answer 70928 QDMA DPDK User Guide Important Note: This downloadable PDF of an Answer Record is provided to enhance its usability and readability. It is important to note that Answer Records are

More information

Trees Algorhyme by Radia Perlman

Trees Algorhyme by Radia Perlman Algorhyme by Radia Perlman I think that I shall never see A graph more lovely than a tree. A tree whose crucial property Is loop-free connectivity. A tree which must be sure to span. So packets can reach

More information

Amazon EC2 Deep Dive. Michael #awssummit

Amazon EC2 Deep Dive. Michael #awssummit Berlin Amazon EC2 Deep Dive Michael Hanisch @hanimic #awssummit Let s get started Amazon EC2 instances AMIs & Virtualization Types EBS-backed AMIs AMI instance Physical host server New root volume snapshot

More information

Power Systems with POWER8 Scale-out Technical Sales Skills V1

Power Systems with POWER8 Scale-out Technical Sales Skills V1 Power Systems with POWER8 Scale-out Technical Sales Skills V1 1. An ISV develops Linux based applications in their heterogeneous environment consisting of both IBM Power Systems and x86 servers. They are

More information

Virtual Private Networks (VPN)

Virtual Private Networks (VPN) CYBR 230 Jeff Shafer University of the Pacific Virtual Private Networks (VPN) 2 Schedule This Week Mon September 4 Labor Day No class! Wed September 6 VPN Project 1 Work Fri September 8 IPv6? Project 1

More information

Rack Disaggregation Using PCIe Networking

Rack Disaggregation Using PCIe Networking Ethernet-based Software Defined Network (SDN) Rack Disaggregation Using PCIe Networking Cloud Computing Research Center for Mobile Applications (CCMA) Industrial Technology Research Institute 雲端運算行動應用研究中心

More information

NEC Express5800/B120e-h System Configuration Guide

NEC Express5800/B120e-h System Configuration Guide NEC Express5800/B120e-h System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

I/O virtualization. Jiang, Yunhong Yang, Xiaowei Software and Service Group 2009 虚拟化技术全国高校师资研讨班

I/O virtualization. Jiang, Yunhong Yang, Xiaowei Software and Service Group 2009 虚拟化技术全国高校师资研讨班 I/O virtualization Jiang, Yunhong Yang, Xiaowei 1 Legal Disclaimer INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE,

More information

Management Component Transport Protocol (MCTP) IDs and Codes

Management Component Transport Protocol (MCTP) IDs and Codes 1 2 3 4 Document Number: DSP0239 Date: 2009-11-03 Version: 1.1.0 5 6 Management Component Transport Protocol (MCTP) IDs and Codes 7 8 9 Document Type: Specification Document Status: DMTF Standard Document

More information

Neousys Technology Inc. PCIe-PoE2+/PCIe-PoE4+ User s Manual. Rev. A1

Neousys Technology Inc. PCIe-PoE2+/PCIe-PoE4+ User s Manual. Rev. A1 Neousys Technology Inc. PCIe-PoE2+/PCIe-PoE4+ 2-Port/4-Port x4 PCI-E Gigabit Power over Ethernet Frame Grabber Card User s Manual Rev. A1 Published Apr 10 th, 2012 Page 1 of Contents Declaimer...3 Declaration

More information

Installing and Configuring Windows Server Installing and Configuring Windows Server 2012

Installing and Configuring Windows Server Installing and Configuring Windows Server 2012 Installing and Configuring Windows Server 2012 Number: 70-410 Passing Score: 800 Time Limit: 120 min File Version: 29.0 Installing and Configuring Windows Server 2012 Sections 1. Volume A 2. Volume B 3.

More information