2 QUESTION: 49 A technician applies an IPv4 address to the Out-Of-Band/Management port of a Dell NSeries switch. Which step allows the technician to use the web interface? A. Update the Switch Firmware to at least version 6.3.x.x. B. use the default Dell root username and calvin password. C. Manually set a username and password via the CLI. D. Configure an enable password on the Dell N-Series switch. Answer: B QUESTION: 50 Refer to the output. Which two actions occur if interface Tw2/0/2 goes down? (Choose two.) A. Switch 1 becomes a standalone switch. B. Switch 2 remains in the stack. C. Switch 2 becomes a standalone switch. D. Switch 3 remains in the stack. E. Switch 3 becomes a standalone switch. Answer: B, D QUESTION: 51 Root bridge Switch A is connected to Switch B. They are connected using the same corresponding interfaces Gi1/01 and Gi1/0/2 on both sides. Which interface becomes a root port?
3 A. Switch A Gi1/0/1 B. Switch A Gi1/0/2 C. Switch B Gi1/0/1 D. Switch B Gi1/0/2 Answer: C QUESTION: 52 Two N3024F switches are directly connected using 10GBASE-SR transceivers and 10 foot fiber patch cables. The ports on both sides are NOT linking. What are two possible reasons for this issue? (Choose two.) A. The fiber connectors are inverted. B. The transceivers are on SFP ports. C. The fiber length is too short. D. The connection is using multimode fiber. E. The fiber is unidirectional. Answer: A, B QUESTION: 53 Refer to the output: console#show interfaces switchport te1/0/1 Port: Te1/0/1 VLAN Membership Mode: General Mode Access Mode VLAN: 1 (default) General Mode PVID: 9 General Mode Ingress Filtering: Enabled General Mode Acceptable Frame Type: Admit All General Mode Dynamically Added VLANs: General Mode Untagged VLANs: 1, 9 General Mode Tagged VLANs: General Mode Forbidden VLANs: Trunking Mode Native VLAN: 1 (default) Trunking Mode Native VLAN Tagging: Disabled Trunking Mode VLANs Enabled: All Private VLAN Host Association: none Private VLAN Mapping: Private VLAN Operational Bindings: Default Priority: 0 Protected: Disabled console# What VLAN will untagged ingress traffic be assigned? A. VLAN 20 B. VLAN 9 C. VLAN 10 D. VLAN 1 Answer: D
4 QUESTION: 54 Refer to the output: console#show interfaces switchport gigabitethernet 1/0/5 Port: Gi1/0/5 VLAN Membership Mode: Access Mode Access Mode VLAN: 3 General Mode PVID: 1 (default) General Mode Ingress Filtering: Enabled General Mode Acceptable Frame Type: Admit All General Mode Dynamically Added VLANs: General Mode Untagged VLANs: 1 General Mode Tagged VLANs: General Mode Forbidden VLANs: Trunking Mode Native VLAN: 1 (default) Trunking Mode Native VLAN Tagging: Disabled Trunking Mode VLANs Enabled: All Private VLAN Host Association: none Private VLAN Mapping: Private VLAN Operational Bindings: Default Priority: 0 Protected: Disabled Port Gi1/0/5 on a Dell N2024 will be used to create an IEEE 802.1Q-compliant trunk to another switch. Why will the trunk fail to form? A. The correct IP address has not been configured. B. Native VLAN tagging is disabled. C. VLANs have not been created on this switch. D. The port is currently configured for a single VLAN. Answer: D QUESTION: 55 A technician inserts an SFP+transceiver into an N3024F 1 Gbps port on the front panel. The transceiver does NOT work. What is the reason for this issue? A. SFP+transceivers are incompatible with SFP slots on an N3024F front panel. B. The port is disabled by default and must be enabled on the switch prior to usage. C. SFP+transceiver is defective and must be replaced. D. SFP+transceivers are identified by the Bale Clasp and must be color matched to the port. Answer: A QUESTION: 56 A technician enables Dot1x RADIUS authentication globally on all ports on the N2000 switch. All ports show as unauthorized and management access to the switch has been lost. What is causing network connectivity loss on the switch? A. dot1x port-control force-authorized is not applied to the uplink interface. B. The RADIUS server has provided a command unauthorized to shut down all links.
5 C. dot1x port-mode auto is not applied to the uplink interface. D. A user fails authentication, which causes all network access to shut down. Answer: A QUESTION: 57 A Dell N2024 switch receives a frame from a directly connected host. The switch learns that the source MAC address is NOT present in the MAC address table. The destination address is present in the MAC address table. What does the switch do with the frame? A. Floods the frame to all ports except for the port the frame originated from to find the source MAC address. B. Flushes the destination MAC address and updates the MAC address table in the switch. C. Discards the frame on all ports and sends an error message back to the host. D. Adds the source MAC address and port to the MAC address table and forwards the frame. Answer: D
6 For More exams visit Kill your exam at First Attempt...Guaranteed!
Configuring Interfaces
CHAPTER 9 This chapter defines the types of interfaces on the Cisco ME 3400 Ethernet Access switch and describes how to configure them. Understanding Interface Types, page 9-1 Using Interface Configuration
More informationConfiguring Voice VLAN
CHAPTER 15 This chapter describes how to configure the voice VLAN feature on the Catalyst 3750 switch. Unless otherwise noted, the term switch refers to a standalone switch and a switch stack. Voice VLAN
More informationConfiguring Interfaces
CHAPTER 9 This chapter defines the types of interfaces on the Cisco ME 3400 Ethernet Access switch and describes how to configure them. The chapter consists of these sections: Understanding Interface Types,
More informationConfiguring Interface Characteristics
CHAPTER 12 This chapter defines the types of Catalyst 2975 interfaces and describes how to configure them. Unless otherwise noted, the term switch refers to a standalone switch and a switch stack. Understanding
More informationConfiguring Interface Characteristics
CHAPTER 10 This chapter defines the types of interfaces on the switch and describes how to configure them. Unless otherwise noted, the term switch refers to a standalone switch and to a switch stack. The
More informationInterface and Hardware Components Configuration Guide, Cisco IOS XE Everest 16.6.x (Catalyst 9300 Switches)
Interface and Hardware Components Configuration Guide, Cisco IOS XE Everest 16.6.x (Catalyst 9300 Switches) First Published: 2017-07-31 Last Modified: 2017-11-03 Americas Headquarters Cisco Systems, Inc.
More informationitexamdump 최고이자최신인 IT 인증시험덤프 일년무료업데이트서비스제공
itexamdump 최고이자최신인 IT 인증시험덤프 http://www.itexamdump.com 일년무료업데이트서비스제공 Exam : 642-813 Title : Implementing Cisco IP Switched Networks Vendor : Cisco Version : DEMO Get Latest & Valid 642-813 Exam's Question
More informationNCT240 IP DSLAM with IAC4500 VLAN Tagging Implementation
NCT240 IP DSLAM with IAC4500 VLAN Tagging Implementation The NetComm NCT240 24 Port IP DSLAMs support 802.1Q VLAN Tagging. This white paper is written to help IP DSLAM system integrator to set up and configure
More informationUser Handbook. Switch Series. Default Login Details. Version 1.0 Edition
User Handbook Switch Series Zyxel GS1920 / GS2210 / XGS2210 / GS3700 / XGS3700 / XGS4600 / XS1920 / XS3700 Default Login Details LAN IP Address https://192.168.1.1 User Name admin Password 1234 Version
More informationConfiguring Interface Characteristics
Finding Feature Information, page 1 Information About, page 1 How to Configure Interface Characteristics, page 11 Monitoring Interface Characteristics, page 28 Configuration Examples for Interface Characteristics,
More informationConfiguring IEEE 802.1x Port-Based Authentication
CHAPTER 10 Configuring IEEE 802.1x Port-Based Authentication IEEE 802.1x port-based authentication prevents unauthorized devices (clients) from gaining access to the network. Unless otherwise noted, the
More informationConfigure to Secure a Flexconnect AP Switchport with Dot1x
Configure to Secure a Flexconnect AP Switchport with Dot1x Contents Introduction Prerequisites Requirements Components Used Configure Network Diagram Verify Troubleshoot Introduction This document describes
More informationConfiguring Access and Trunk Interfaces
Configuring Access and Trunk Interfaces Ethernet interfaces can be configured either as access ports or trunk ports. Trunks carry the traffic of multiple VLANs over a single link and allow you to extend
More informationConfiguring IEEE 802.1x Port-Based Authentication
CHAPTER 9 Configuring IEEE 802.1x Port-Based Authentication This chapter describes how to configure IEEE 802.1x port-based authentication on the Catalyst 2960 switch. IEEE 802.1x authentication prevents
More informationConfiguring Interface Characteristics
CHAPTER 11 This chapter defines the types of interfaces on the Catalyst 3750 switch and describes how to configure them. Unless otherwise noted, the term switch refers to a standalone switch and a switch
More informationConfiguring 802.1X Port-Based Authentication
CHAPTER 10 This chapter describes how to configure IEEE 802.1X port-based authentication on the Catalyst 3750 switch. As LANs extend to hotels, airports, and corporate lobbies, creating insecure environments,
More informationEurolan Ltd.- Sofia, bul. Tzarigradsko shoes, 7km, building 3, floor 5 phone , mobile: Port
Basic uration for 4-PON port OLT Port Port information show interfaces brief Port uration Gigabit Etherent or EPON ports interface gigaethernet 0/[x] - [x] - gigaethernet port number or interface EPON
More informationWith 802.1X port-based authentication, the devices in the network have specific roles.
This chapter contains the following sections: Information About 802.1X, page 1 Licensing Requirements for 802.1X, page 9 Prerequisites for 802.1X, page 9 802.1X Guidelines and Limitations, page 9 Default
More informationA Dell Interoperability Whitepaper Victor Teeter
Deployment of Dell M8024-k Blade Switch with Cisco Nexus 5000 Series Switch A Dell Interoperability Whitepaper Victor Teeter THIS TECHNICAL INTEROPERABILITY WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY,
More information48-Port 10/100/1000BASE-T + 4-Port 100/1000BASE-X SFP Gigabit Managed Switch GS T4S
48-Port 10/100/1000BASE-T + 4-Port 100/1000BASE-X SFP Gigabit Managed Switch GS-4210-48T4S Outlines Product Overview Product Benefits Applications Appendix Product Features 2 / 42 Product Overview Layer
More informationPeplink SD Switch User Manual
Peplink SD Switch User Manual Peplink Products: Peplink SD Switch 8-ports/24-ports/48-ports Peplink SD Switch Firmware 1.2.0 Published on December 10, 2018 Copyright & Trademarks Copyright & trademark
More informationVLAN Configuration via CLI on 300/500 Series Managed Switches
Article ID: 4986 4986 - VLAN Configuration via CLI on 300/500 Series Managed Switches Objective VLANs allow you to logically segment a LAN into different broadcast domains. In scenarios where sensitive
More informationHuawei H HCNP R&S Fast Track.
Huawei H12-224 HCNP R&S Fast Track http://killexams.com/pass4sure/exam-detail/h12-224 Question: 591 Which statements about the MUX VLAN configuration are true? (Select 2 Answers) [Quidway]vlan 10 [Quidway-vlan10]mux-vlan
More informationNumerics. Index 1. SSH See SSH. connection inactivity time 2-3 console, for configuring authorized IP managers 11-5 DES 6-3, 7-3
Numerics 3DES 6-3, 7-3 802.1X See port-based access control. 8-1 A aaa authentication 4-8 aaa port-access See Web or MAC Authentication. access levels, authorized IP managers 11-3 accounting address authorized
More informationConfiguring Private VLANs
Finding Feature Information, on page 1 Prerequisites for Private VLANs, on page 1 Restrictions for Private VLANs, on page 1 Information About Private VLANs, on page 2 How to Configure Private VLANs, on
More informationConfiguring IEEE 802.1Q Tunneling and Layer 2 Protocol Tunneling
CHAPTER 14 Configuring IEEE 802.1Q Tunneling and Layer 2 Protocol Tunneling With Release 12.1(13)E and later, the Catalyst 6500 series switches support IEEE 802.1Q tunneling and Layer 2 protocol tunneling.
More informationDXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch Web UI Reference Guide
1 Information in this document is subject to change without notice. Reproduction of this document in any manner, without the written permission of the D-Link Corporation, is strictly forbidden. Trademarks
More informationHP0-Y49. Applying HP FlexNetwork Fundamentals.
HP HP0-Y49 Applying HP FlexNetwork Fundamentals http://killexams.com/exam-detail/hp0-y49 QUESTION: 54 Refer to the Exhibit. Exhibit: HP Comware switch configuration. [Comware] vlan 100 [Comware-vlan100]
More informationInterfaces for Firepower Threat Defense
This chapter includes Firepower Threat Defense interface configuration including Ethernet settings, EtherChannels, VLAN subinterfaces, IP addressing, and more. About Firepower Threat Defense Interfaces,
More informationConfiguring IEEE 802.1x Port-Based Authentication
CHAPTER 8 Configuring IEEE 802.1x Port-Based Authentication This chapter describes how to configure IEEE 802.1x port-based authentication on the switch. IEEE 802.1x authentication prevents unauthorized
More informationWith 802.1X port-based authentication, the devices in the network have specific roles.
This chapter contains the following sections: Information About 802.1X, page 1 Licensing Requirements for 802.1X, page 8 Prerequisites for 802.1X, page 8 802.1X Guidelines and Limitations, page 9 Default
More informationCHAPTER 1: VLANS. Routing & Switching
CHAPTER 1: VLANS Routing & Switching CHAPTER 1 1.1 VLAN Segmentation 1.2 VLAN Implementation 1.3 VLAN Security and Design 1.4 Summary CHAPTER 1 : OBJECTIVES Explain the purpose of VLANs in a switched network.
More informationConfiguring VLANs. Understanding VLANs CHAPTER
CHAPTER 12 This chapter describes how to configure normal-range VLANs (VLAN IDs 1 to 1005) and extended-range VLANs (VLAN IDs 1006 to 4094) on the switch. It includes information about VLAN membership
More informationNGSME24T2H-AV. (24-Rear Port 10/100/1000Base-T PoE + 2 Gigabit SFP Layer 2+ Management Current Sharing PoE+ Switch)
NGSME24T2H-AV (24-Rear Port 10/100/1000Base-T PoE + 2 Gigabit SFP Layer 2+ Management Current Sharing PoE+ Switch) More information: WWW.NIVEOPROFESSIONAL.COM INFO@NIVEOPROFESSIONAL.COM Product Specification
More informationConfigure IBNS 2.0 for Single-Host and Multi- Domain Scenarios
Configure IBNS 2.0 for Single-Host and Multi- Domain Scenarios Contents Introduction Prerequisites Requirements Components Used Configure Configuration Theory Scenario for Single-Host Scenario for Multi-Domain
More informationBrocade FastIron Flexible Authentication
18 December 2015 Brocade FastIron Flexible Authentication Deployment Guide Supporting FastIron 08.0.40 2015, Brocade Communications Systems, Inc. All Rights Reserved. ADX, Brocade, Brocade Assurance, the
More informationCCNP Switch Questions/Answers Securing Campus Infrastructure
What statement is true about a local SPAN configuration? A. A port can act as the destination port for all SPAN sessions configured on the switch. B. A port can be configured to act as a source and destination
More informationExample: Configuring IP Source Guard on a Data VLAN That Shares an Interface with a Voice VLAN
Example: Configuring IP Source Guard on a Data VLAN That Shares an Interface with a Voice VLAN Requirements Ethernet LAN switches are vulnerable to attacks that involve spoofing (forging) of source IP
More informationConfiguring Link Aggregation
Information About Link Aggregation, page 1 Restrictions for Link Aggregation, page 2 (GUI), page 4 (CLI), page 4 Verifying Link Aggregation Settings (CLI), page 5 Configuring Neighbor Devices to Support
More informationHow to configure the IAC4500 Internet Access Controller for Billing by Volume Application with NCT480 IP DSLAM using port location mapping
How to configure the IAC4500 Internet Access Controller for Billing by Volume Application with NCT480 IP DSLAM using port location mapping Introduction The following paper provides instructions on how
More informationConfiguring SPAN and RSPAN
CHAPTER 32 This chapter describes how to configure Switched Port Analyzer (SPAN) and Remote SPAN (RSPAN) on the Catalyst 3750-X or 3560-X switch. Unless otherwise noted, the term switch refers to a Catalyst
More informationIEEE 802.1ad Support on Provider Bridges
IEEE 802.1ad Support on Provider Bridges First Published: April 19, 2010 Last Updated: May 26, 2011 Service provider bridges (also called provider bridges) allow switches in a service provider network
More informationConfiguring LLDP, LLDP-MED, and Wired Location Service
CHAPTER 28 Configuring LLDP, LLDP-MED, and Wired Location Service This chapter describes how to configure the Link Layer Discovery Protocol (LLDP), LLDP Media Endpoint Discovery (LLDP-MED) and wired location
More informationCisco Implementing Cisco IP Switched Networks (SWITCH v2.0)
Cisco 300-115 Implementing Cisco IP Switched Networks (SWITCH v2.0) https://killexams.com/pass4sure/exam-detail/300-115 QUESTION: 272 What VSS technology allows you to share downstream resources? A. LACP
More informationAmphenol. RJ-Switch. IP67/68 rugged Ethernet Managed Switch RES-SCE-8MG - Command Line Interface
RJ-Switch IP67/68 rugged Ethernet Managed Switch RES-SCE-8MG - This manual applies to the following products: RES-SCE-8MG (NOLED) (other options) Rugged IP67/68 Managed Ethernet Switch, with SCE2 reinforced
More informationVLAN Configuration. Understanding VLANs CHAPTER
CHAPTER 11 This chapter describes how to configure normal-range VLANs (VLAN IDs 1 to 1005) and extended-range VLANs (VLAN IDs 1006 to 4094) on the CGR 2010 ESM. It includes information about VLAN membership
More information1. Which two statements are true about VLAN implementation? (Choose two.)
CCNA 2 Chapter 3 v5.0 Exam Answers 2015 (100%) 1. Which two statements are true about VLAN implementation? (Choose two.) The size of the collision domain is reduced. The number of required switches in
More informationConfiguring VLANs. Understanding VLANs CHAPTER
CHAPTER 9 This chapter describes how to configure normal-range VLANs (VLAN IDs 1 to 1005) and extended-range VLANs (VLAN IDs 1006 to 4094). It includes information about VLAN membership modes, VLAN configuration
More informationConfiguring EtherChannels and Layer 2 Trunk Failover
35 CHAPTER Configuring EtherChannels and Layer 2 Trunk Failover This chapter describes how to configure EtherChannels on Layer 2 and Layer 3 ports on the switch. EtherChannel provides fault-tolerant high-speed
More informationSWP-0208G, 8+2SFP. 8-Port Gigabit Web Smart Switch. User s Manual
SWP-0208G 1 SWP-0208G, 8+2SFP 8-Port Gigabit Web Smart Switch User s Manual Version: 3.4 April 1, 2008 2 TABLE OF CONTENT 1.0 INTRODUCTION...4 1.1 MAIN FEATURES...4 1.2 START TO MANAGE THIS SWITCH...6
More informationConfiguring Port-Based Traffic Control
CHAPTER 18 This chapter describes how to configure port-based traffic control features on the Catalyst 3750 Metro switch. For complete syntax and usage information for the commands used in this chapter,
More informationHP HP ProCurve Security. Download Full Version :
HP HP0-757 HP ProCurve Security Download Full Version : https://killexams.com/pass4sure/exam-detail/hp0-757 A. Create communities; create groups; assign communities to groups B. Create users; assign users
More informationNGSME16T2H. (16-port 10/100/1000Base-T + 2 Gigabit SFP L2+ Management PoE Switch)
NGSME16T2H (16-port 10/100/1000Base-T + 2 Gigabit SFP L2+ Management PoE Switch) More information: WWW.NIVEOPROFESSIONAL.COM INFO@NIVEOPROFESSIONAL.COM Product Specification Introduction The NGSM16ET2H
More informationDEPLOYING A STACK OF DELL M-SERIES BLADE SWITCHES IN SIMPLE SWITCH MODE (SSM)
Deploying DEPLOYING A STACK OF DELL M-SERIES BLADE SWITCHES IN SIMPLE SWITCH MODE (SSM) Victor Lama DELL Network Sales Engineer Banking and Securities v1.0 5 APR 2012 A detailed case study of a client
More informationCatalyst 4500 Series IOS Commands
CHAPTER Catalyst 4500 Series IOS Commands New Commands dot1x guest-vlan supplicant ip dhcp snooping information option allow-untrusted port-security mac-address port-security mac-address sticky port-security
More informationSave installation time and money with PoE.
48-Port Gigabit Ethernet PoE+ Layer2+ Managed Switch with 10 GbE Uplink 48 x PoE ports, IEEE 802.3at Power over Ethernet (PoE+), Layer 2+, 2 x 10 GbE SFP+ open slots, Endspan, 19" Rackmount Part No.: 561112
More informationConfiguring IEEE 802.1Q Tunneling
CHAPTER 26 This chapter describes how to configure IEEE 802.1Q tunneling in Cisco IOS Release 12.2SX. For complete syntax and usage information for the commands used in this chapter, see the Cisco IOS
More informationConfiguring VLANs. Understanding VLANs CHAPTER
CHAPTER 14 This chapter describes how to configure normal-range VLANs (VLAN IDs 1 to 1005) and extended-range VLANs (VLAN IDs 1006 to 4094) on the Catalyst 3750 switch. It includes information about VLAN
More informationManagement Software AT-S101. User s Guide. For use with the AT-GS950/8POE Gigabit Ethernet WebSmart Switch. Version Rev.
Management Software AT-S101 User s Guide For use with the AT-GS950/8POE Gigabit Ethernet WebSmart Switch Version 1.0.0 613-000985 Rev. A Copyright 2008 Allied Telesis, Inc. All rights reserved. No part
More informationConfiguring EtherChannels and Layer 2 Trunk Failover
28 CHAPTER Configuring EtherChannels and Layer 2 Trunk Failover This chapter describes how to configure EtherChannels on Layer 2 ports on the switch. EtherChannel provides fault-tolerant high-speed links
More informationPeplink SD Switch User Manual. Published on October 25th, 2018
Peplink SD Switch User Manual Published on October 25th, 2018 1 Table of Contents Switch Layout 4 Specifications 5 Hardware Overview 6 Quick Start Functions 7 Reset Switch 7 Connect Ethernet 7 Connect
More informationCISCO SWITCH BEST PRACTICES GUIDE
CISCO SWITCH BEST PRACTICES GUIDE Table of Contents (After Clicking Link Hit HOME to Return to TOC) 1) Add Hostname... 2 2) Add Username and Password... 2 3) Create Secret Password... 2 4) Encrypt Password...
More informationH3C S12500 VLAN Configuration examples
H3C S12500 VLAN Configuration examples Copyright 2014 Hangzhou H3C Technologies Co., Ltd. All rights reserved. No part of this manual may be reproduced or transmitted in any form or by any means without
More informationGetting Started with Your Device Configuration
Quick Setup Tasks, page 1 Quick Setup Tasks On the first day with your new device, you can perform a number of tasks to ensure that your device is online, reachable and easily configured. The Day 0 wizard
More informationFor information about configuring these settings from Cluster Management Suite (CMS), refer to the online help.
Configuring VLANs This chapter provides information about configuring virtual LANs (VLANs). It includes command-line interface (CLI) procedures for using commands that have been specifically created or
More informationNGSME48T2H. (48-Port 10/100/1000Base-T Gigabit Combo TP/SFP Layer 2+ Full Management High Power PoE Switch)
NGSME48T2H (48-Port 10/100/1000Base-T+ 2 10-Gigabit Combo TP/SFP Layer 2+ Full Management High Power PoE Switch) * 48-Port PoE Gigabit Copper + 2-port 10-Gigabit ComboTP/ SFP+ * 802.3az Energy Efficient
More informationMR2324-4C. 24-Port Intelligent Gigabit Ethernet Switch. Management Guide
MR2324-4C 24-Port Intelligent Gigabit Ethernet Switch Management Guide Management Guide Intelligent Gigabit Ethernet Switch with 24 10/100/1000BASE-T (RJ-45) Ports, and 4 Combination RJ-45/SFP Ports E082004-R01
More informationVLAN - SP6510P8 2013/4. Copyright 2011 Micronet Communications, INC
VLAN - SP6510P8 2013/4 www.micronet.info Copyright 2011 Micronet Communications, INC Agenda VLAN Protocol VLAN Voice VLAN www.micronet.info 2 Micronet Communications Inc. Benefit Bandwidth Preservation
More informationConfiguring VLANs. Understanding VLANs CHAPTER
CHAPTER 11 This chapter describes how to configure normal-range VLANs (VLAN IDs 1 to 1005) and extended-range VLANs (VLAN IDs 1006 to 4094) on the Cisco ME 3400 Ethernet Access switch. It includes information
More informationAddendum & Corrigendum-2 Request for Proposal
Addendum & Corrigendum-2 Request for Proposal For Creation of OFC Network for BRTS Corridor and other important SMC Locations Connected Surat Project Part 1 RFP No.: SSCDL-ConnectedSurat-OFC-RFP-01-2017
More informationInternetwork Expert s CCNA Security Bootcamp. Mitigating Layer 2 Attacks. Layer 2 Mitigation Overview
Internetwork Expert s CCNA Security Bootcamp Mitigating Layer 2 Attacks http:// Layer 2 Mitigation Overview The network is only as secure as its weakest link If layer 2 is compromised, all layers above
More informationConfiguring Fibre Channel Interfaces
This chapter contains the following sections:, page 1 Information About Fibre Channel Interfaces Licensing Requirements for Fibre Channel On Cisco Nexus 3000 Series switches, Fibre Channel capability is
More informationInterfaces for Firepower Threat Defense
This chapter includes Firepower Threat Defense interface configuration including Ethernet settings, EtherChannels, VLAN subinterfaces, IP addressing, and more. About Firepower Threat Defense Interfaces,
More informationJetNet 5228G / 5228G-DC
JetNet 5228G / 5228G-DC 24+4G Standalone Managed RoHS 24 10/100-TX and 4 Gigabit RJ-45/SFP combo ports (10/100/1000 Base-TX, 1000 Base-X) Design for the Building, Control Room and Telecom applications
More informationSwitch Quick Configuration CLI Guide for
Switch Quick Configuration CLI Guide for SSE-G48-TG4 SSE-G24-TG4 SSE-X24S SBM-GEM-X2C SBM-GEM-X2C+ SBM-GEM-X3S+ SBM-XEM-X10SM Release : 1.0b 1 / 19 The information in this User s Manual has been carefully
More informationActual4Test. Actual4test - actual test exam dumps-pass for IT exams
Actual4Test http://www.actual4test.com Actual4test - actual test exam dumps-pass for IT exams Exam : 642-999 Title : Implementing Cisco Data Center Unified Computing Vendor : Cisco Version : DEMO Get Latest
More informationConfiguring the Catalyst 3750G Integrated Wireless LAN Controller Switch
APPENDIXA Configuring the Catalyst 3750G Integrated Wireless LAN Controller Switch The Catalyst 3750G Integrated Wireless LAN Controller Switch is an integrated Catalyst 3750 switch and Cisco 4400 series
More informationConfiguring Cisco IP Phone Support
CHAPTER 16 This chapter describes how to configure support for Cisco IP phones on the Catalyst 6500 series switches. For complete syntax and usage information for the commands used in this chapter, refer
More informationConfiguring SPAN and RSPAN
Finding Feature Information, page 1 Prerequisites for SPAN and RSPAN, page 1 Restrictions for SPAN and RSPAN, page 2 Information About SPAN and RSPAN, page 3 How to Configure SPAN and RSPAN, page 14 Monitoring
More information12- or 24-Port 10-Gigabit/Multi-Gigabit Ethernet Switch with 2 SFP+ Combo Ports User Manual
12- or 24-Port 10-Gigabit/Multi-Gigabit Ethernet Switch with 2 SFP+ Combo Ports User Manual Models XS512EM and XS724EM February 2018 202-11841-03 350 E. Plumeria Drive San Jose, CA 95134 USA Support Thank
More informationConfiguring Port-Based and Client-Based Access Control (802.1X)
9 Configuring Port-Based and Client-Based Access Control (802.1X) Contents Overview..................................................... 9-3 Why Use Port-Based or Client-Based Access Control?............
More informationManagement Software AT-S67 AT-S68. User s Guide FOR USE WITH AT-FS7016 AND AT-FS7024 SMART SWITCHES VERSION PN Rev A
Management Software AT-S67 AT-S68 User s Guide FOR USE WITH AT-FS7016 AND AT-FS7024 SMART SWITCHES VERSION 1.0.0 PN 613-50494-00 Rev A Copyright 2003 Allied Telesyn, Inc. 960 Stewart Drive Suite B, Sunnyvale,
More informationCisco CCIE SP IP Telephony Qualification.
Cisco 350-024 CCIE SP IP Telephony Qualification http://killexams.com/exam-detail/350-024 Question: 386 Question: 381 A Calling Search Space can be used by CallManager to: A. Enable the use of an overlapping
More informationConfiguring VLAN Trunks
Finding Feature Information, page 1 Prerequisites for VLAN Trunks, page 1 Information About VLAN Trunks, page 2 How to Configure VLAN Trunks, page 5 Configuration Examples for VLAN Trunking, page 20 Where
More informationMatrix V-Series V2H FAST ETHERNET SWITCH. Configuration Guide
Matrix V-Series V2H124-24 FAST ETHERNET SWITCH Configuration Guide Notice ELECTRICAL HAZARD: Only qualified personnel should perform installation procedures. NOTICE Enterasys Networks reserves the right
More informationSwitch Configuration. The Switch Configuration Menu screen (Figure 3-6) allows you to set or modify your switch configuration.
Switch Configuration The Switch Configuration Menu screen (Figure 3-6) allows you to set or modify your switch configuration. Note: The High Speed Flow Control Configuration option only appears when an
More informationConfiguring Private VLANs Using NX-OS
This chapter describes how to configure private VLANs on Cisco NX-OS devices. Private VLANs provide additional protection at the Layer 2 level. This chapter includes the following sections: Finding Feature
More informationConfiguring 802.1X. Finding Feature Information. Information About 802.1X
This chapter describes how to configure IEEE 802.1X port-based authentication on Cisco NX-OS devices. This chapter includes the following sections: Finding Feature Information, on page 1 Information About
More informationPFC and Untagged Frames
PFC and Untagged Frames bb-ghanwani-pfc-untagged-0509-v1 Anoop Ghanwani (anoop@brocade.com) Dan Eisenhauer (dge@us.ibm.com) Rakesh Sharma (rakesh@us.ibm.com) May 2009 Overview Motivation Types of untagged
More informationSave installation time and money with PoE.
16-Port Gigabit Ethernet PoE+ Web-Managed Switch with 2 SFP Ports 16 x PoE ports, IEEE 802.3at/af Power over Ethernet (PoE+/PoE), 2 x SFP, Endspan, Desktop, 19" Rackmount Part No.: 560931 Save installation
More informationTL-SG5428 TL-SG5412F. 24-Port Gigabit L2 Managed Switch with 4 SFP Slots. 12-Port Gigabit SFP L2 Managed Switch with 4 Combo 1000BASE-T Ports REV2.1.
TL-SG5428 24-Port Gigabit L2 Managed Switch with 4 SFP Slots TL-SG5412F 12-Port Gigabit SFP L2 Managed Switch with 4 Combo 1000BASE-T Ports REV2.1.1 1910010847 COPYRIGHT & TRADEMARKS Specifications are
More informationConfiguring VLANs. Understanding VLANs CHAPTER
7 CHAPTER This chapter describes how to configure normal-range VLANs (VLAN IDs 1 to 1005) and extended-range VLANs (VLAN IDs 1006 to 4094) on the Cisco MWR 2941 router. It includes information about VLAN
More informationConfiguring SPAN and RSPAN
Prerequisites for SPAN and RSPAN, page 1 Restrictions for SPAN and RSPAN, page 1 Information About SPAN and RSPAN, page 3 How to Configure SPAN and RSPAN, page 14 Monitoring SPAN and RSPAN Operations,
More informationCatalyst 4500 Series IOS Commands
CHAPTER Catalyst 4500 Series IOS Commands New Commands call-home (global configuration) call-home request call-home send call-home send alert-group call-home test clear energywise neighbors clear errdisable
More informationCisco Networking Academy CCNP
Semester 3 v5 -Chapter 8 Cisco Networking Academy CCNP Minimizing Service Loss and Data Theft in a Campus Network Switch security concerns Network security coverage often focuses on edge-routing devices
More information8-port 10/100/1000M PoE + 2 Gigabit SFP/RJ45 Copper Combo Ports
ALL-SG8910PM 8-port 10/100/1000M PoE + 2 Gigabit SFP/RJ45 Copper Combo Ports IEEE 802.3at/af PoE, up to 30W per port Layer 2+ Full Managed Software Features with MSTP, LACP, LLDP, sflow, 802.1X, RADIUS,
More informationChapter 3: VLANs. Routing & Switching
Chapter 3: VLANs Routing & Switching VLAN Definitions A VLAN is a logical partition of a Layer 2 network. VLANs logically group hosts, regardless of physical location. Multiple partitions can be created,
More informationConfiguring VLANs. Understanding VLANs CHAPTER
CHAPTER 16 This chapter describes how to configure normal-range VLANs (VLAN IDs 1 to 1005) and extended-range VLANs (VLAN IDs 1006 to 4094) on your Catalyst 2950 or Catalyst 2955 switch. It includes information
More informationConfiguring EtherChannels and Link-State Tracking
CHAPTER 37 Configuring EtherChannels and Link-State Tracking This chapter describes how to configure EtherChannels on Layer 2 and Layer 3 ports on the switch. EtherChannel provides fault-tolerant high-speed
More informationConfiguring Ethernet Virtual Connections on the Cisco ASR 1000 Series Router
Configuring Ethernet Virtual Connections on the Cisco ASR 1000 Series Router Ethernet virtual circuit (EVC) infrastructure is a Layer 2 platform-independent bridging architecture that supports Ethernet
More information