Pluvi-ONE. Quick user guide
|
|
- Trevor Neil Price
- 5 years ago
- Views:
Transcription
1 Pluvi-ONE Quick user guide INSTUM_02424_en MW6180 upd. 29/09/2017
2 Instrument description (1) - On/Off switch (2) - Lightning sensor input (opt.) (3) - USB ports (4) - Ethernet port (5) - Com1 serial port (modem) (6) - Com2 serial port (service) (7) - LCD display 4x20 characters (8) - Keyboard (9) - LEDs operating status (10) - Terminal board Terminal board INPUTS - Pulse1, Pulse2: Pulse Counters - Pt100: thermoresistance - SDI-12: SDI-12 serial line (Com5) - LCD On: display ignition contact - Analog In: current 4 20 ma - T/RH: thermo-hygrometer (Com4) - RS-485: RS-485 serial line (Com3) ACTUATORS - Pwr Out1 (only available with T/RH input free), Pwr Out2, Pwr Out3 SUPPLY - Batt/Pwr In: power supply - PV In: photovoltaic module input 2
3 PC connection 1. Insert the LAN cable into the Pluvi-ONE Ethernet port and the computer port. 2. Connect the power supply to the terminal block (14+, 16-) on the terminal board. 3. Set the computer IP address in the range with subnet mask Turn on Pluvi-ONE using the On/Off switch. Installing 3DOM 3DOM is the instrument configuration program; it is stored in the USB key - LSI LASTEM products. Follow the instructions of the Setup program for the installation. At the first run of 3DOM you must register the instrument you are using. Proceed as follows: 1. Start 3DOM. 2. Choose New from the Instrument menu. 3. Choose Pluvi-ONE and press Continue. 4. Enter the instrument serial number and its password shown on the label on the back. 5. Set the SSH connection type, the IP address and press Save. To enable the connection with Pluvi-ONE you must activate the Advanced mode (menu SYSTEM/Advanced mode) by directly operating the instrument keyboard. Configuration Pluvi-ONE needs to be configured with measurement parameters, connectivity and (if required) actuators and alarms. Creating a new configuration 1. In the 3DOM Instrument panel, select the instrument serial number. 2. Choose New from the Configuration menu. 3. Select the empty configuration template and press OK. 4. Assign a name to the configuration e press OK. Configuring the measurement parameters Select Measures from the Data Logging section and, for each sensor used: 1. Press the Add button, search for the desired sensor using the sensor P/N or searching for it in the membership category, and press the OK button. In case the required instrument is not listed, select a similar one and modify its parameters (name, unit of measure, etc.) or create a new one using the New button. 2. On the Elaborations tab, add the desired elaborations by setting the elaboration rate and the desired statistical elements. 3
4 3. On the Parameters tab, verify that the update rate and the power on time mode are the desired ones. 4. In case two measurements have the same name, we suggest to change one of them. 5. Press OK to accept the measure. Connectivity parameters Communication between Pluvi-ONE and external devices takes place by means of different network protocols. Therefore, you must configure the network connection parameters according to the protocol you are actually going to use. 3DOM allows you to configure the following network connections: Ethernet If enabled, allows SSH connection via PC. If an FTP Server is configured, it allows to send data on the specified FTP site and to update the configuration via FTP. Default value: IP: , Subnet mask: Wi-Fi It can be used as an alternative connection using a Wi-Fi transmitter (not included). It has the same functionality as Ethernet connection. Default value: not configured. PPP To be used with a cellular modem. It has the same functionality as Ethernet connection. Modem configuration on COM1 is required. Default value: not configured. Some features may require setting server parameters. Supported servers are as follows: DNS Server SMTP Server NTP Server FTP Server If configured, Pluvi-ONE can recognize the names of the network IP devices. You must specify it if you use names instead of IP addresses in SMTP Server, NTP Server and FTP Server. Default value: If configured, Pluvi-ONE can send s. Default value: not configured. If configured, Pluvi-ONE can keep its internal clock synchronized. Default value: 0.pool.ntp.org and 1.pool.ntp.org. It is the FTP site address where data will be sent and where configuration update files will be retrieved. It requires one of the following connectivity: Ethernet, Wi-Fi or PPP. Default value: not configured. Actuators and alarms Pluvi-ONE has 3 actuators (switched excitation channels) that can be used for powering external devices such as sensors and modems or for switching on alarm devices. It is also able to send s or SMS when certain conditions defined in the actuation logics occurs. To add an actuation logic, proceed as follows: 1. Select Logics in the Events section and press the Add button. 2. Choose the logic type and press the Add button. 3. Assign a name to the logic, set the required parameters and press OK. 4
5 To associate a logic to an actuator, proceed as follows: 1. Select Actions in the Events section; select the actuator number and press the Edit button. 2. Check the name of the previously entered logic and press OK. Saving configuration and sending to Pluvi-ONE To save the configuration, press the Save button on the 3DOM Toolbar. To upload the configuration on the instrument: 1. In the Configurations tab select the configuration name. 2. Right-click on the selected name and choose Upload 3. Select SSH mode and press the Edit button. 4. Enter on the Instrument IP field and press Save. 5. Press OK to start the operation. When the configuration upload ends, the instrument will restart with the new settings. Connecting sensors Sensors must be connected to the instrument according the resident 3DOM configuration. For this reason, we recommend to generate a Configuration report in order to identify the input used. Connection of sensors to the terminal board turned off. must be performed with the instrument Measurement display When Pluvi-ONE is turned on and when the display standby is activated by pressing the key, the instrument displays product information V B A T T e r i a T E M P e r a t u r a U m i d R E L a t i v a To switch to compressed mode (short name of measurement, acquired value and unit of measurement), press and choose Change view. Repeat the key sequence to return to extended mode. L A S T > C h a n g e v i e w M E A S U R E S C h a n g e s c r o l l m o d e L S I L A S T E M P l u v i - O N E I t a l y for a few seconds and then the measurements list in extended mode (full name of measurement and acquired value). V B A T T V T E M P C U R E L % If the measurements are more than four, they scroll down to the top. To pause scrolling, press and choose Change scroll mode. Use to move to the desired measurements. 5
6 Repeat the key sequence to return to scrolling mode. Operational checkafter connecting the sensors and verifying the correct acquisition of the measurements, we recommend to check the connectivity features (sending data to FTP site, sending mail, sending SMS, etc.) You can test some connectivity parameters from the CONNECTIVITY submenu, accessible from the ADVANCED FEATURES menu. > E t h e r n e t W i P P P - F i C O N N E C T I V I T Y C F G : S T A T I C I P : N M : G W : S M S Here s an example of settings for the Ethernet port. Product identification The serial number and the firmware version of Pluvi-ONE are visible from ABOUT... on the SYSTEM menu. Identification info is also on the label on the back of the instrument. L S I L A S T E M P l u v i - O N E E L P S N F W
7 NOTES This manual is an introduction to the use of Pluvi-ONE. For more information refer to the INSTUM_02422 Pluvi-ONE User s guide included on the USB Key - LSI Lastem products. Disposal Pluvi-ONE is a highly electronic scientific device. In accordance with the standards of environmental protection and collection, LSI LASTEM advises to handle Pluvi-ONE as waste of electrical and electronic equipment (WEEE). It is therefore not to be collected with any other kind of waste. LSI LASTEM is liable for the compliance of the production, sales and disposal lines of Heat Shield, safeguarding the rights of the consumer. Unauthorized disposal will be punished by the law. Dispose of the dead batteries according to the regulations in force How to contact LSI LASTEM If you need technical support contact the LSI LASTEM at support@lsi-lastem.it, or fill in the On-line technical support request form accessible from the home page of the website For further information: Telephone: (switchboard operator) Address: Via ex S.P. 161 Dosso n Settala (MI) - Italy Web site: Sales: info@lsi-lastem.it After-sales service: support@lsi-lastem.it 7
8 8
X-Log Expert Data Logger
> data loggers X-Log Expert Data Logger Highlights Built-in internet stack with web server Setup and data display by any web browser Data-Push to up to three different FTP sites Internal FTP site for easy
More informationHot wire anemometers ESV306 and ESV307. User manual
Hot wire anemometers ESV306 and ESV307 User manual LSI LASTEM SRL INSTUM_1412 Update: 04/30/2014 Index 1 Introduction... 3 1.1 Notes about this manual... 3 2 Product installation... 4 2.1 Mechanical mounting...
More information3DOM Free Data logger Oriented Manager User Manual Revision 2018/02/08
3DOM Free Data logger Oriented Manager User Manual Revision 2018/02/08 Cod. SWUM_00339_en LSI LASTEM 3DOM User s manual Index 1. Introduction... 4 2. System Requirements... 4 3. Installation... 5 3.1.
More informationHeat Shield. User s manual
Heat Shield User s manual Document Heat Shield User s manual Pages 28 Revision list Issue Date Author Changed description Origin 02/02/2015 Reschiotto - Astori a 09/03/2015 Reschiotto - Astori CE compliance
More informationpresents ENVIRONMENTAL MONITORING & INDUSTRIAL MEASUREMENT IP connected Data Loggers
presents ENVIRONMENTAL MONITORING & INDUSTRIAL MEASUREMENT IP connected Data Loggers Neon IP Dataloggers Neon Remote Loggers 3 Neon Remote Logger 16 Hi Res Analog Channels/Touch Screen Display Internet
More informationETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel
Ethernet Module ETHM-2 Firmware version 1.0 ethm2_en 09/08 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.pl SATEL's goal is to continually improve
More informationDocument Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter
Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Login for the first time, please use http://192.168.1.100 To key in user name and password is for identifying authorization. Default
More informationSX100 as a NTP Server
SX100 as a NTP Server Version 1.0.0.5 Page 1 Table of contents Table of contents... 2 Introduction:... 3 System and Network Requirements:... 4 Installed on a SX100:... 5 Operation:... 6 Set External NTP
More informationHD32MTLogger Software Manual for the instrument HD32MT.1 Introduction
HD32MTLogger Software Manual for the instrument HD32MT.1 Introduction WARNING: The software must always be run as administrator! The HD32MTLogger program allows management of the HD32MT.1 datalogger from
More informationHT101. User terminal. Function
HT101 User terminal Summary HT101 is a human-machine interface for monitoring and control of multiple MiniPLC, IPCT.1, IPCB.1 controllers, or other SoftPLC runtimes working on different platforms. It has
More informationPluvi-ONE. Rain monitoring and early warning system. Components. General Catalog. data loggers MW9009 ENG 5/ MW9009-ENG
>> PLUVI-ONE Rain monitoring and early warning system 1 2 3 4 2 3 4 4 5 6 7 8 Components Pluvi-ONE Rain monitoring and early warning system data loggers Milano ITALY General Catalog MW9009-ENG MW9009 ENG
More informationcmt Quick Start Guide
cmt Quick Start Guide Your Industrial Control Solutions Source www.maplesystems.com For use with the following: cmt-svr cmt-d090 Maple Systems, Inc. 808 134 th St. SW, Suite 120, Everett, WA 98204 425.745.3229
More informationTechnical support and product information. LAE electronic TAB4.
User s guide Technical support and product information http://www.lae-electronic.com/ info@lae-electronic.com Page 2 LAE electronic TAB4.2 - User s guide TAB 4.2 - User s guide INTRODUCTION TAB is a software
More informationLuminato. Quick Start Manual. Teleste Corporation. Luminato First Time Installation. SW version 1.1.2
Luminato Quick Start Manual Teleste Corporation Luminato First Time Installation SW version 1.1.2 Luminato Quick Start Manual, agile_59300317, rev002 BB 11-07-2008 Contents i Contents Introduction 3 Assumptions...3
More informationPanoramic Power Installation and configuration guide
Panoramic Power Installation and configuration guide Advanced 4th generation Bridge for firmware v259 Version 1 1 Copyright notice Copyright 2017 Panoramic Power Ltd. All rights reserved. Panoramic Power
More informationCommunication Interface
Communication Interface Com'X 200/Com'X 210/Com'X 510 Technical data sheet Communications & gateways Com'X 200 / 210 Energy data loggers Main functions 1. Measure 2. Connect 3. Save PB114855 Wireless Meter
More informationProduct Family: Networking Hardware Number: AN-NH-012
APPLICATION NOTE THIS INFORMATION PROVIDED BY AUTOMATIONDIRECT.COM TECHNICAL SUPPORT These documents are provided by our technical support department to assist others. We do not guarantee that the data
More informationFX Tools Software Package - FX CommPro N2 User s Guide
User s Guide FX CommPro N2 Issue Date September 25, 2008 FX Tools Software Package - FX CommPro N2 User s Guide FX Tools Software Package FX CommPro N2... 3 Introduction...3 Installation... 4 Installing
More informationConfiguring the WT-4 for ftp (Infrastructure Mode)
En Configuring the WT-4 for ftp (Infrastructure Mode) Mac OS X Introduction This document provides basic instructions on configuring the WT-4 wireless transmitter and a Mac OS X (10.5.2) ftp server for
More informationGuide Features and Benefits
Loading Dock and Mobile Pick- Up Solutions Guide Guide Features and Benefits VEHICLE DETECTION INDICATION EVENT COUNTERS TOTAL AND AVERAGE TIME EXTENDED TIME INDICATION SMS TEXT/EMAIL ALERTS CLOUD MONITORING
More informationX-Log User Guide Updated 15 January 2016
X-Log User Guide Updated 15 January 2016 Cod. INSTUM_01513_en Summary 1. First start-up... 3 2. Interface with the datalogger... 5 3. Web access... 6 3.1. Web configuration for acquisition channels...
More informationObelux Control Panel Web Server
AVIATION LIGHTS Obelux Control Panel Web Server User and Installation Manual With software version 5.x Last modified: 12.05.2013 (RJä) 2013 Obelux Oy Page: 1(18) CONTENTS 1 ABOUT THIS DOCUMENT... 4 1.1
More informationOperating Instructions Firmware Update Guide
Operating Instructions Firmware Update Guide For safe and correct use, be sure to read the Safety Information in Read This First before using the machine. TABLE OF CONTENTS 1. Firmware Update Guide Overview...3
More informationSPORTY - First start guide & useful hints MAYAH Communications
2 1 1.1 Before Start 1.2 Check if scope of delivery (see chapter Scope of Delivery) is complete with help of the included packing list. Recharge the original SPORTY battery with the original SPORTY charger
More informationNI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server
DATALOGGER NI2400/NI816/NI4866 8/16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATASHEET Rev. 08 del 08/10/2018 Redatto da R&D Approvato da MKT GENERAL 1SPECIFICATIONS NI4866 NI816 NI2400
More informationIMIO100 IMIO105. DDC controllers. Summary
IMIO100 IMIO105 DDC controllers Summary DDC (Direct digital control) controller IMIO100 and IMIO105 are free programmable process stations with ARM Cortex M4 processor and OS FreeRTOS. They contain one
More informationDON T WASTE INSTALL TIME!
[ DON T WASTE INSTALL TIME! Before you go to the project site, read all sections of this manual that apply to your system specifications! [ COMMERCIAL INSTALLATION GUIDE v12_04_02 COMMERCIAL INSTALL GUIDE
More informationmark150s mark150/485s DDC controllers Summary
mark150s mark150/485s DDC controllers Summary DDC (Direct digital control) controller mark150s and mark150/485s are free programmable process stations with ARM Cortex M4 processor and OS FreeRTOS. They
More informationA. Insert CD and wait until the installation wizard comes up on your screen
1. Software Installation A. Insert CD and wait until the installation wizard comes up on your screen B. After reading the Setup Guide Click Install Software C. If you do not have.net Framework installed
More informationAUTOMATIC AND AUTONOMOUS REMOTE WATER LEVEL AND WATER QUALITY MONITORING STATION
Brochure nº 9722.0048 AUTOMATIC AND AUTONOMOUS REMOTE WATER LEVEL AND WATER QUALITY MONITORING STATION MODEL HYDRODATA-2000C SERIES GEONICA, S.A. - Alejandro Rodríguez, nº 22-28039 Madrid - Spain Tel.
More informationIN-SESSION ROOM SCHEDULER
SETUP GUIDE: COMMON SETTINGS RS-TOUCH SERIES IN-SESSION ROOM SCHEDULER 24/7 AT OR BLACKBOX.COM TABLE OF CONTENTS 1. INTRODUCTION... 3 1.1 Description... 3 1.2 Network Infrastructure Requirements... 3 1.3
More informationIMS4 AMS 111 II M. Automatic Mobile Weather Station for military usage AMS 111 II M
IMS4 Automatic Mobile Weather Station for military usage FEATURES: Military class equipment Military design optional Aviation weather observation Climatological observation Synoptic observation Radiation
More information3DOM Free Data logger Oriented Manager User Manual Revision 2014/11/03
3DOM Free Data logger Oriented Manager User Manual Revision 2014/11/03 Cod. SWUM_00339_en LSI LASTEM 3DOM User s manual Index 1. Introduction... 4 2. System Requirements... 4 3. Installation... 5 3.1.
More informationTCPIPINT-SCMN USER MANUAL. Manufactured by R.V.R ELETTRONICA S.p.A. Italy
USER MANUAL Manufactured by R.V.R S.p.A. Italy File Name: _ING_1.0.indb Version: 1.0 Date: 15/04/2016 Revision History Date Version Reason Editor 15/04/2016 1.0 First edition J. H. Berti - User Manual
More informationDatalogger Gealog SG. Datalogger Gealog SG. Gealog SG with graphic display
Gealog SG with graphic display Page 1 of 13 Innovation leader in environmental monitoring stations The Gealog SG datalogger was especially designed for application in hydrometeorological measuring stations.
More informationWindows 95/98 Infoway Connection Instructions 1/4/2002; rev. 1/9/2002
Windows 95/98 Infoway Connection Instructions 1/4/2002; rev. 1/9/2002 The following are the basic steps for setting up your computer for a PPP connection to the library s Infoway Internet service. A PPP
More informationPaperless Recorders & Data Acquisition Solutions SEE, STORE, SEND DATA SECURELY. Honeywell Solutions for Data Acquisition and Batch Recording
Paperless Recorders & Data Acquisition Solutions SEE, STORE, SEND DATA SECURELY Honeywell Solutions for Data Acquisition and Batch Recording See, store, send data securely The X-Series Family of Recorders
More informationHOME AUTOMATION. MY-HAND, the whole house under your control with one single instrument.
TELECO AUTOMATION SRL - Via dell Artigianato, 16-31014 Colle Umberto (TV) ITALY TELEPHONE: ++39.0438.388511 FAX: ++39.0438.388536 - www.telecoautomation.com This document is the property of Teleco Automation
More informationCONVERTER FOR MONITORING STATION SMET-256
CONVERTER FOR MONITORING STATION SMET-256 USER MANUAL Program version v1.07 smet256_en 04/11 SATEL's goal is to continually improve the quality of its products, which may lead to alterations in their technical
More informationR4, R8, R16 Digital Video Recorders Quick Setup Guide
R4, R8, R16 Digital Video Recorders Quick Setup Guide This guide provides instructions to initially setup the R16 (16 channel) digital video recorders (DVR). The DVR supports these advanced features: 2
More informationATL20 ATL30 Automatic transfer switch controller
I 194 GB 07 07 ATL20 ATL30 Automatic transfer switch controller REMOTE CONTROL SOFTWARE MANUAL Summary Introduction... 2 Minimum resources of the PC... 2 Installation... 2 Activation of the PC-ATL connection...
More informationHighPROTEC Troubleshooting Guide
HighPROTEC Troubleshooting Guide HighPROTEC Troubleshooting Guide Contents HighPROTEC Troubleshooting Guide... 2 Troubleshooting by means of the System-OK-LED status... 3 Troubleshooting Hardware... 6
More informationThe Cosy 131 User Guide USER MANUAL
The Cosy 131 User Guide USER MANUAL UM-0004-00 EN 1.1 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial Networks SA
More informationCONTROL TECHNOLOGY CORPORATION. qmon User's Guide. Control Technology Corp
CONTROL TECHNOLOGY CORPORATION qmon User's Guide Control Technology Corp. www.ctc-control.com 800.282.5008 WARNING: Use of CTC Controllers and software is to be done only by experienced and qualified personnel
More information9936A LogWare III. User s Guide. Revision
9936A LogWare III User s Guide Revision 680301 Table of Contents 1 Introduction... 1 1.1 Symbols Used...1 1.2 Conventions...1 1.3 What is LogWare?...1 1.4 License Agreement...2 1.5 Requirements...2 1.6
More informationEMSOW PACS Bridge. Downloading EMSOW PACS Bridge. Installing EMSOW PACS Bridge
EMSOW PACS Bridge EMSOW PACS Bridge is a desktop application that allows you to transfer DICOM images from your diagnostic equipment to your EMSOW site using a secure, encrypted connection. You can obtain
More informationFT2 View Instruction Manual
399 Reservation Road, Marina, California U.S.A. Ph: (831) 384-4300 Fax: (831) 337-5786 www.foxthermalinstruments.com 2006 Fox Thermal Instruments, Inc. 07/19/13 Introduction: The FT2 View application software
More informationelan-rs485/ /2017 / rev.0 Page 1 of 19
Page 1 of 19 Introduction... 4 Device description... 4 Examples connection... 5 Installing, IP address... 6 Logging to the web interface... 7 Settings... 8 Settings description of functions... 9 Devices
More informationHighPROTEC Troubleshooting Guide
HighPROTEC Troubleshooting Guide HighPROTEC Troubleshooting Guide Contents HighPROTEC Troubleshooting Guide... 2 Self-supervision Messages... 3 Troubleshooting by means of the System-OK-LED status... 5
More informationNetwork Keyboard. Quick Start Guide UD01317N
Network Keyboard Quick Start Guide UD01317N Quick Start Guide About this Guide This Guide is applicable to network keyboard. The Guide includes instructions for using and managing the product. Pictures,
More informationPOS Android Digital Advertising Display (Network) Hardware User Manual
POS Android Digital Advertising Display (Network) Hardware User Manual Manual Version POSW3.0 Safety Instructions Please keep the display away from any heat sources. Place the display in a stable and well-ventilated
More informationC1002 IP Camera. Quick Installation Guide. Solwise Ltd., 1
C1002 IP Camera Quick Installation Guide Solwise Ltd., www.solwise.co.uk, sales@solwise.co.uk 1 Trademarks and/or registered trademarks are the property of their respective owners The information presented
More informationDeploy the ExtraHop Discover Appliance 1100
Deploy the ExtraHop Discover Appliance 1100 Published: 2018-07-17 The following procedures explain how to deploy an ExtraHop Discover appliance 1100. System requirements Your environment must meet the
More informationINSTRUCTION MANUAL V1. 2x A
INSTRUCTION MANUAL V1. 2x A INTRODUCTION... 3 CONNECTIONS AND INSTALLATION... 4 MECHANICAL INSTALLATION... 4 ATTACHING AND DETACHING THE FRONT COVER... 8 ATTACHING AND DETACHING THE HMI... 9 ELECTRICAL
More informationConfiguring the WT-4 for Upload to a Computer (Ad-hoc Mode)
En Configuring the WT-4 for Upload to a Computer (Ad-hoc Mode) Mac OS X Introduction This document provides basic instructions on configuring the WT-4 wireless transmitter and a Mac OS X (10.5.2) computer
More informationUser s manual WiFi RS
WiFi RS I. Safety 4 II. Description 5 III. Module installation 6 IV. First start-up 6 V. IV. How to configure the module (for the latest controller versions) 7 IV.a) How to log in to the website 7 IV.b)
More informationCom X 210, Com X 510 Technical Datasheet
Com X 210, Com X 510 Technical Datasheet A highly flexible plug-and-play Energy Server Com X 210 collects and stores WAGES consumptions and environmental parameters such as temperatures, humidity and CO
More informationOMNIAlog. Start Guide
OMNIAlog Start Guide NOTES ON THE USE OF PRODUCT For a safe and efficient use of the product, please read carefully the following instruction before starting any operation. The user must perform carefully
More informationSite Book User s Guide
Issue Date 11/01/01 USER S GUIDE...3 Introduction... 3 Key Concepts... 5 Related Documentation...5 Communications Options...5 N30 Supervisory Controller...5 Project Builder...6 N30 Upgrade Utility...6
More informationIMS AMS 111 II. Automatic Weather Station. Easy and reliable weather monitoring anywhere
IMS II Automatic Weather Station Easy and reliable weather monitoring anywhere IMS Automatic Weather Station FEATURES: Synoptic Observation Climatological Observation Environmental Monitoring Radiation
More informationPowerLogic TM Series E4800 Multi-Circuit Meters. Configuration Guide
PowerLogic TM Series E4800 Multi-Circuit Meters Configuration Guide PowerLogic TM E4800 Series 930-112-01 02/2009 Hazard Categories and Special Symbols Read these instructions carefully and look at the
More informationMXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.
MXPLC Compact PLC process station Summary The MXPLC is a programmable process station with integrated I/O module with the I/O mix optimized for larger HVAC control applications. The multi-interface process
More information9936A LogWare III. User s Guide. Revision
9936A LogWare III User s Guide Revision 850701 Table of Contents 1 Introduction...1 1.1 Symbols Used... 1 1.2 Conventions... 1 1.3 What is LogWare?... 1 1.4 License Agreement... 2 1.5 Requirements...
More informationPowerLogic TM Series EM4800 Multi-Circuit Meters. Configuration Guide
PowerLogic TM Series EM4800 Multi-Circuit Meters Configuration Guide PowerLogic TM EM4800 Series 930-112-01-B.00 01/2011 Hazard Categories and Special Symbols Read these instructions carefully and look
More informationTHE WORLD OF WEATHER DATA
THIES Clima Meteorology and Environmental measurements. Datalogger DL16 PRO 2009 Adolf Thies GmbH & Co. KG 1 Content 1. Highlights 2. Introduction 3. Connectivity 4. Configuration 5. Miscellaneous Configuration
More informationSYNERGY. Supervision and energy management software INSTRUCTION MANUAL
SYNERGY Supervision and energy management software INSTRUCTION MANUAL INDEX 1 INTRODUCTION... 4 2 HARDWARE AND SOFTWARE REQUIREMENTS... 4 3 SETUP... 4 4 SYNERGY LOGIN AND USERS... 5 4.1 Users... 5 4.2
More informationEATON 5S 850/1200/1600
www.eaton.com EATON 5S 850/1200/1600 Installation and user manual Packaging EATON 5S 1 2 3 5 Caution! l Before installing the Eaton 5S, read the booklet 3 containing the safety instructions to be respected.
More informationManual Version: V1.00. Video Decoder User Manual
Manual Version: V1.00 Video Decoder User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang
More informationIP WEB User Manual V2.0
IP WEB User Manual V2.0 Please read carefully before installing or contacting your supplier. The information contained at the time of printing is correct, but is subject to change without notice. This
More informationLesson 10. Circuit Boards and Devices Ethernet and Wi-Wi Connectivity with the Internet
Lesson 10 Circuit Boards and Devices Ethernet and Wi-Wi Connectivity with the Internet 1 Connecting Arduino USB to Internet Arduino board IDE supports USB. USB port connects to a mobile or computer or
More informationROHS AND WEEE COMPLIANCE
210Z ROHS AND WEEE COMPLIANCE All lead-free products offered by the company comply with the requirements of the European law on the Restriction of Hazardous Substances (RoHS) directive, which means our
More informationOne Expert TM. Handheld Manager, version 1.1. User s Guide
One Expert TM Handheld Manager, version 1.1 User s Guide One Expert TM Handheld Manager, version 1.1 User s Guide Notice Every effort was made to ensure that the information in this document was accurate
More informationOperating Instructions. Windows. Video Wall Adjustment & Calibration Software. Video Wall Manager Ver. 1.8
Operating Instructions Video Wall Adjustment & Calibration Software Windows Video Wall Manager Ver. 1.8 Thank you for purchasing this Panasonic product. Before using this software, please read the instructions
More informationN30 Supervisory Controller Quick Start
Issue Date June 30, 2004 TECHNICAL BULLETIN N30 Supervisory Controller Quick Start N30 Supervisory Controller Quick Start...2 Introduction... 2 Key Concepts... 3 Using This Document... 3 Related Information...
More informationINSTRUCTION MANUAL VDR MAINTENANCE VIEWER
INSTRUCTION MANUAL VDR MAINTENANCE VIEWER MODEL VR-3000/VR-3000S This manual is solely for use by the installer. Under no circumstances shall this manual be released to the user. The installer shall remove
More informationQuick Installation Guide DAP N300 Wi-Fi Range Extender
N300 Wi-Fi Range Extender BEFORE YOU BEGIN Delivery Package Extender (brochure). If any of the items are missing, please contact your reseller. The User Manual and documents are available on D-Link website
More informationSierra Wireless AirLink LS300. Setup Steps
Sierra Wireless AirLink LS300 Description The target of the Airlink LS300 is the Alarming Module. Its purpose is to Send and Receive SMS messages. Essentially, it is going to be utilized as an SMS gateway.
More informationTemperature and Humidity Monitoring Solutions Guide
Temperature and Humidity Monitoring Solutions Guide Guide Features and Benefits TEMPERATURE & HUMIDITY MONITORING WARNINGS AND ALARMS LOCAL INDICATION LIGHTS REMOTE MASTER LIGHT SMS TEXT/EMAIL ALERTS TIME-STAMPED
More informationGuide Features and Benefits
Guide Features and Benefits REMOTE MOTOR CONTROL MOTOR RUN TIME EVENT COUNTERS STATUS INDICATION MOTOR AUXILIARY STATUS TIME STAMPED LOGGING SMS TEXT/EMAIL ALERTS EFFICIENCY METRICS CLOUD MONITORING Remote
More informationSST Configure Software OPERATION MANUAL
SST Configure Software OPERATION MANUAL Trilithic Company Profile Trilithic is a privately held manufacturer founded in 1986 as an engineering and assembly company that built and designed customer-directed
More informationDash Jr. User Manual Table of Contents
(/usermanuals) Dash Jr. User Manual Table of Contents Safety Information Safety Information Call Functions Contacts Messaging Opera Mini Browser Bluetooth & Wi Fi Camera Gallery Music Sound Recorder Alarm
More informationDD-600. A member of the Data Dolphin Family of Data Logging Systems. Data Dolphin Installation and Usage Manual
A member of the Data Dolphin Family of Data Logging Systems Real Time Wireless Monitoring Solution Data Dolphin Installation and Usage Manual Last Revision: May 2012-1 - Note to the user: This manual may
More informationEasy Config. Configuration tool for ATYS, COUNTIS and DIRIS INSTRUCTION MANUAL. easy-config_software
INSTRUCTION MANUAL Easy Config Configuration tool for ATYS, COUNTIS and DIRIS EN www.socomec.com/ easy-config_software www.socomec.com EN CONTENTS 1. DOCUMENTATION...3 2. PRELIMINARY OPERATIONS...3 3.
More informationA5500 Configuration Guide
A5500 Configuration Guide Sri Ram Kishore February 2012 Table of contents Gateway Configuration... 3 Accessing your gateway configuration tool... 3 Configuring your broadband Internet access... 3 Configuring
More informationMachine Monitoring Solutions Guide. Guide Features and Benefits. Equipment
Guide Features and Benefits MACHINE MONITORING UP TIME EVENT COUNTERS PART COUNTING REMOTE MASTER LIGHT TIME STAMPED LOGGING SMS TEXT/EMAIL ALERTS EFFICIENCY METRICS CLOUD MONITORING Monitor machine inputs
More informationConfiguring the WT-4 for ftp (Ad-hoc Mode)
En Configuring the WT-4 for ftp (Ad-hoc Mode) Windows XP Introduction This document provides basic instructions on configuring the WT-4 wireless transmitter and a Windows XP Professional SP2 ftp server
More informationGMSplus Customer Connection Test Procedure
GMS-xx Customer Connection Test Procedure Page 1/14 GMSplus Customer Connection Test Procedure Company: Author: Checked: Approved: Distribution: GeoSIG Ltd Wiesenstrasse 39, 8952 Schlieren, Switzerland,
More informationRX300 Settings Manual General
RX300 Settings Manual General The RX300 is provisioned by the administrator. The settings can be modified remotely from vspace Console or the RX300 device itself. In the General tab, the administrator
More informationTVLink RS868 ETHERNET INTERFACE
TELECO AUTOMATION SRL - Via dell Artigianato, 16-31014 Colle Umberto (TV) ITALY TELEPHONE: ++39.0438.388511 FAX: ++39.0438.388536 - www.telecoautomation.com This document is the property of Teleco Automation
More informationIntroduction. M A G L I N Samplers support data acquisition from the following data acquisition modules and instruments:
Introduction M A G L I N is a computer program designed to perform continuous unattended data acquisition from one or more instruments, with sampling rates typically between 0.01Hz and 800Hz. It has been
More informationCOMMUNICATION WITH OTHER SERIAL DEVICES
Application Bulletin: #169 Date: November 2009 BLACKBELT COMMUNICATIONS INTERFACE The setup and operation of the Sentinel BLACKBELT communication options are explained in Error! Reference source not found.,
More informationSuitcase SmartStruxure Lite Solution
Suitcase SmartStruxure Lite Solution Commissioning Instructions Version Commissioning Instructions SUITCASE - SMARTSTRUXURE LITE SOLUTION Congratulations on acquiring your SmartStruxure Lite solution suitcase.
More informationSM00 _ MENHIR STRONG MOTION SYSTEM
_ MENHIR STRONG MOTION SYSTEM MENHIR STRONG MOTION SYSTEM MENHIR SM (Strong Motion) is based on a new high performance and versatile platform for industrial, geotechnical, vibrational and strong motion
More informationDATENBLATT. DT85-Serie. dex Logger Software ab Seite 14
DATENBLATT DT85-Serie dex Logger Software ab Seite 14 HABEN SIE FRAGEN ODER WÜNSCHEN SIE EIN INDIVIDUELLES ANGEBOT? Unser Team berät Sie gerne persönlich. TELEFON + 49 (0) 81 41/36 97-0 TELEFAX + 49 (0)
More informationUser Guide. For controller on CXAO / RTXB heat pumps CGCM / CXCM 2 circuit units. CNT-SVU005C-GB Original instructions
User Guide For controller on CXAO / RTXB heat pumps CGCM / CXCM 2 circuit units CNT-SVU005C-GB Original instructions Table of contents Advanced electronics... 3 Technical Specifications... 4 Display description...
More informationBridgemate Pager. Messaging system for tournament directors. Manual Bridge Systems BV
Bridgemate Pager Messaging system for tournament directors Manual 2017 Bridge Systems BV Bridgemate Pager Manual Page 2 Contents Introduction... 3 Requirements... 3 How the pager system works... 3 Installing
More informationIntegrate APC Smart UPS
Publication Date: November 18, 2016 Abstract This guide provides instructions to configure APC Smart-UPS to send the syslog events to EventTracker. Scope The configurations detailed in this guide are consistent
More informationU90 Ladder Software Manual. Version 3.50, 6/03
U90 Ladder Software Manual Version 3.50, 6/03 Table Of Contents Welcome to U90 Ladder... 1 Program Editors... 1 Project Navigation Tree...1 Browse Sequences...1 Printing Documentation...2 Interface Language...
More informationWINDOWS NT 4.0 USER GUIDE
WINDOWS NT 4.0 USER GUIDE This guide will assist you in connecting to Nauticom using your Windows NT 4.0 Operating System. Click Start. Select Settings, and click Control Panel. Double click the Network
More informationGenIP : Intelligent gateway dedicated to most critical industrial applications
GenIP 20i / GenIP 30i June 2012 GenIP : Intelligent gateway dedicated to most critical industrial applications Monitor your alarms (Voice, SMS, Email, TCP frame) Manage securely your serial & Ethernet
More information