1 Front cover Introduction to - Networking Designs Last Update: 7 November 2017 Explains three-tier versus spine-leaf network architectures Details the advantages and disadvantages of three-tier and spine-leaf architectures Introduces Lenovo s recommended spine-leaf switches Details the capacities of Lenovo s recommended spine-leaf implementations William Nelson

2 Abstract The traditional three-layer network topologies are losing momentum in the modern data center and are being supplanted by spine-leaf designs (also known as Clos designs after one of the original researchers, Charles Clos). This is even despite three-layer familiarity, scalability and ease of implementation. Why is this happening? Organizations are seeking to maximize the function and utilization of their data centers leading to architecture optimized for software defined and cloud solutions. The spine-leaf architecture provides a strong base for the software defined data center optimizing the reliability and bandwidth available server communications. This document describes the following: The traditional three-layer and spine-leaf architectures The advantages and disadvantages of each architecture approach Lenovo s spine-leaf solutions This paper is for network architects and decision makers desiring to understand why spine-leaf designs are important to the modern data center and how Lenovo Networking products can be utilized in these designs. At Lenovo Press, we bring together experts to produce technical publications around topics of importance to you, providing information and best practices for using Lenovo products and solutions to solve IT challenges. See a list of our most recent publications at the Lenovo Press web site: Do you have the latest version? We update our papers from time to time, so check whether you have the latest version of this document by clicking the Check for Updates button on the front page of the PDF. Pressing this button will take you to a web page that will tell you if you are reading the latest version of the document and give you a link to the latest if needed. While you re there, you can also sign up to get notified via whenever we make an update. Contents Approaches for Network Designs Lenovo spine-leaf Conclusion Appendix: Lenovo spine-leaf capacities Acronyms Change history Author Notices Trademarks Introduction to - Networking Designs

3 Approaches for Network Designs The overall network performance is highly dependent upon the design approach that is utilized. These approaches can be optimized for either north-south or east-west traffic flows. The following three-tier and spine-leaf architectures are two classic approaches utilized to optimize designs for north-south and east-west traffic respectively. Three-tier architecture Data center technologies are driving network architecture changes from the traditional three-tier architecture, as shown in Figure 1. Layer 3 Layer 2 Routing Switch (L3/L2) Switch 1 (L2) Pod 1 Routing Switch (L3/L2) Switch n (L2) Routing Switch (L3/L2) Switch 1 (L2) Pod 2 Routing Switch (L3/L2) Switch n (L2) Routing Switch (L3/L2) Switch 1 (L2) Pod n Routing Switch (L3/L2) Switch n (L2) Aggregation Access Figure 1 Traditional three-tier architecture This architecture consists of three major layers: 1. Layer 3 routers providing separation of the pods 2. Aggregation Layer 2/3 (L2/3) switches which serve as boundaries between the pods. 3. Access Layer 2 (L2) switches providing loop free pod designs utilizing either spanning tree protocol or virtual link aggregation (VLAG) as displayed in Figure 1. The three-tier architecture has served the data center well for many years providing effective access to servers within the pod and isolation between the pods. This matches very cleanly with traditional server functions which require east-west traffic within the pod but limited North/South traffic across pods thru the core network. The difficulty that arises with this architecture is an increased latency for pod-to-pod (east-west) traffic. Advantages of the three-tier architecture The three-tier architecture has been in existence for many years and displacing this for other approaches should not be taken lightly since it is well known and proven. This architecture has distinct benefits including: Copyright Lenovo All rights reserved. 3

4 Availability if a pod is down due to equipment or some other failure, it can be easily isolated to a branch (pod) without affecting other branches (pods) Security processes and data can be isolated in pods limiting exposure risks Performance traffic within the pod is reduced so oversubscription is minimized Scalability if a pod becomes oversubscribed, it is a simple task to add another pod and load-balance traffic across them and improving application performance Simplicity network issues caused by leaf devices are simplified because the number of devices in each branch are limited Disadvantages of the three-tier architecture As previously stated, software defined infrastructures are requiring changes in the traditional network architecture demanding expanded east-west traffic flows. The major software defined applications driving this are virtualization and convergence. Virtualization requires moving workloads across multiple devices which share common backend information. Convergence requires storage traffic between devices on the same network segment. These applications also drive increased bandwidth utilization which is difficult to expand across the multiple layered network devices in the three-tier architecture. This leads to the core network devices being very expensive high speed links. -leaf architecture New data centers are now being designed for cloud architectures with larger east-west traffic domains. This drives the need for a network architectures with an expanded flat east-west domain like spine-leaf as shown in Figure 2 on page 5. Solutions like VMware NSX, OpenStack and others that distribute workloads to virtual machines running on many overlay networks running on top of a traditional underlay (physical) network require mobility across the flatter east-west domain. 4 Introduction to - Networking Designs

5 Figure 2 -leaf Architecture The spine-leaf architecture is also known as a Clos architecture (named after Charles Clos, a researcher at Bell Laboratories in the 1950s) where every leaf switch is connected to each of the spine switch in a full-mesh topology. The spine-leaf mesh can be implemented using either Layer 2 or 3 technologies depending on the capabilities available in the networking switches. Layer 3 spine-leafs require that each link is routed and is normally implemented using Open Shortest Path First (OSPF) or Border Gateway Protocol (BGP) dynamic routing with equal cost multi-path routing (ECMP). Layer 2 utilizes a loop-free Ethernet fabric technology such as Transparent Interconnection of Lots of Links (TRILL) or Shortest Path Bridging (SPB). The core network is also connected to the spine with Layer 3 using a dynamic routing protocol with ECMP. Redundant connections to each spine switch are not required but highly recommended, as show in Figure 2. This minimizes the risk of overloading the links on the spine-leaf fabric. This architecture provides a connection thru the spine with a single hop between leafs minimizing any latency and bottle necks. The spine can be expanded or decreased depending on the data thru-put required. Advantages of the spine-leaf architecture The spine-leaf architecture is optimized for east-west traffic that is required by most software defined solutions. The advantages of this approach are: All interconnections are used and there is no need for STP to block loops All east-west traffic is equidistant so traffic flow has deterministic latency Switch configuration is fixed so that no network changes are required for a dynamic server environment 5

6 Disadvantages of the spine-leaf architecture The spine-leaf architecture is not without concerns as listed below: The leading concern is the amount of cables and network equipment required to scale the bandwidth since each leaf must be connected to every spine device. This can lead to more expensive spine switches with high port counts. The number of hosts that can be supported can be limited due to spine port counts restricting the number of leaf switch connections. Oversubscription of the spine-leaf connections can occur due to a limited number of spine connections available on the leaf switches (typically 4 to 6). Generally, no more than a 5:1 oversubscription ratio between the leaf and spine is considered acceptable but this is highly dependent upon the amount of traffic in your particular environment. Oversubscription of the links out of the spine-leaf domain to the core should also be considered. Since this architecture is optimized for east-west traffic as opposed to north-south, oversubscriptions of 100:1 may be considered acceptable. Lenovo spine-leaf The spine-leaf architecture provides a loop free mesh between the spine and the leaf switches. This can be accomplished using either Layer 2 or 3 designs. Lenovo provides solutions for small two switch Layer 2 spines and expanded multi-switch Layer 3 spines utilizing either Cloud Network Operating System (CNOS) or Enterprise Network Operating System (ENOS). The following sections detail Lenovo s recommendation for spine-leaf switches, and Layer 2 and 3 designs. A table summarizing the scaling of Lenovo's spine-leaf solutions is also provided in Appendix: Lenovo spine-leaf capacities on page 22 as a convenient reference. Lenovo Layer 2 spine-leaf architecture Lenovo implements the Layer 2 spine-leaf network utilizing VLAG to provide a non-blocking loop free design as show in Figure 3 on page 7. Every spine-leaf switch is aggregated in pairs of switches utilizing 100 Gbps spine links providing a 400 Gbps spine with very low congestion. This solution offers the ability to connect to redundant server NICs using bonding with LAG or MAC address load balancing as well as utilizing the NICs independently. 6 Introduction to - Networking Designs

7 connection is possible using L2 with a VLAG or routing using VRRP and ECMP NE2572 Switch 1 NE2572 Switch 2 NE2572 Switch 27 NE2572 Switch 28 Four (4) 100 Gbps links from each leaf switch are utilized for an ISL (2 links) and uplink to the spine (2 links). Figure 3 Lenovo Layer 2 spine-leaf architecture with VLAG at the spine-leaf Each leaf pair has a 400 Gbps VLAG to the spine with a connection to each spine switch from each leaf switch in the pair. NE2572 An alternate Layer 2 design shown in Figure 4 utilizes VLAG only in the spine with a LAG in the leaf switches connecting back to the spine. This solution provides a 200 Gbps spine with slightly higher congestion while providing the ability to connect more servers. Server NICs can be connected as individual NICs or bonding with MAC address load balancing. connection is possible using L2 with a VLAG or routing using VRRP and ECMP Each leaf switch has an 200 Gbps VLAG to the spine with a connection to each spine switch. NE2572 Switch 1 NE2572 Switch 2 NE2572 Switch 27 NE2572 Switch 28 NE2572 Each leaf switch has two (2) 100 Gbps links in a LAG to the spine. Figure 4 Lenovo Layer 2 spine-leaf architecture with VLAG at the spine only Both Layer 2 implementation can connect to the core using Layer 3 with ECMP and VRRP active-active or with VLAG for a full Layer 2 spine implementation. 7

8 Lenovo Layer 3 spine-leaf Architecture Figure 5 is an example of Lenovo s Layer 3 spine-leaf Architecture which utilizes a dynamic routing protocol such as BGP or OSPF to provide connection between all of the spine-leaf switches and core network. While Layer 3 has more complex configurations than Layer 2, it provides a more scalable spine with speeds ranging from 200 to 600 Gbps depending on the type of leaf switch utilized and the number of ThinkSystem spine switches. Layer 3 spine/leaf designs have become more common because L3 (routed) ports have dropped in cost to where they are no more costly than a L2 (switched) port. This is true of the Lenovo switches shown in Figure 5. Future CNOS firmware releases will provide enhanced capabilities to implement virtualized overlay networks using VXLAN and providing redundant Virtual Tunnel End-Points (VTEPs) for virtualization environments. Switch 1 Up to 6 x Switches 2 x 10/25/40/100 Gbps L3 interfaces from each spine switch to core using VRRP and ECMP Switch n NE2572 Switch 1 NE2572 Switch 2 NE2572 Switch 29 NE2572 Switch 30 Each leaf switch has a 100 Gbps L3-only link utilizing ECMP with BGP or OSPF yielding up to 600 Gbps access to the spine. Figure 5 Lenovo Layer 3 spine-leaf architecture using dynamic routing Each leaf switch has an 100 Gbps link to each spine switch. NE2572 Lenovo spine switches The spine switch is used to connect the leaf switches. Lenovo has two recommended leaf switches each with the same number of ports but with different uplink speeds. When considering the spine switch consider the following aspects: Number of leaf switches to be connected Types uplink connections (100/40 Gbps QSFP28 vs 40 Gbps QSFP+) The switch with the least number of 100 or 40 Gigabit ports will limit the cumulative spine speed. 8 Introduction to - Networking Designs

9 Lenovo ThinkSystem RackSwitch Switch The Lenovo ThinkSystem RackSwitch (Figure 6) is Lenovo s preferred spine switch which offers 100 Gbps or 40 Gbps Ethernet spine connections. The has the following features that are important for this spine switch: Layer 2/3 for both routing and switching 32 QSFP28 ports for high speed 100 or 40 Gbps Ethernet connections CNOS for enhanced BGP, OSPF and ECMP routing VLAG for Layer 2 fabric Single chip design for improved latency and buffer management Figure 6 Lenovo ThinkSystem RackSwitch Switch The can connect up to: 28 leaf switches with a L2 implementation with two spine switches and a 200 Gigabit spine without leaf switch VLAG or 14 leaf switches with a 400 Gbps spine with leaf switch VLAG 30 leaf switches with a L3 implementation and a scalable spine up to 600 Gigabit (6 switch) spine Lenovo RackSwitch G8332 Switch The Lenovo RackSwitch G8332 (Figure 7) is a 40 Gbps Ethernet spine switch. The G8332 has the following features that are important for this spine switch: Layer 2/3 for both routing and switching 32 QSFP+ ports for high speed 40 Gbps Ethernet connections CNOS for enhanced BGP, OSPF and ECMP routing VLAG for Layer 2 fabric Single chip design for improved latency and buffer management Lenovo leaf switches Figure 7 Lenovo RackSwitch G8332 Switch The G8332 can connect up to: 28 leaf switches with a L2 implementation with two spine switches and an 80 Gigabit spine without leaf switch VLAG or 14 leaf switches with a 160 Gbps spine with leaf switch VLAG 30 leaf switches with a L3 implementation and a scalable spine up to 400 Gigabit (10 switch) spine The leaf switch is used to connect server nodes. Lenovo has three recommended leaf switches each with varying number of ports and types of connections: Number of ports for connecting to servers Types of server NIC connections Number of 100 or 40 Gbps ports for connecting to the spine 9

10 When considering mixed types of leaf switches, the switch with the least number of 100 or 40 Gigabit ports will limit the cumulative spine speed. switches described in this section: Lenovo ThinkSystem NE2572 RackSwitch Switch Lenovo RackSwitch G8272 Switch on page 12 Lenovo RackSwitch G8296 Switch on page 15 Lenovo EN4093R Switch for Flex System on page 18 Lenovo ThinkSystem NE2572 RackSwitch Switch The Lenovo ThinkSystem NE2572 RackSwitch (Figure 8) is Lenovo s preferred leaf switch which offers 100 Gbps or 40 Gbps Ethernet spine connections and 25 or 10 Gbps server connections. The NE2572 has the following features that are important for this leaf switch: Layer 2/3 for both routing and switching 48 SFP28 ports for 25 or 10 Gbps Ethernet connections to servers 6 QSFP28 ports for high speed 100 or 40 Gbps Ethernet connections to the spine CNOS for enhanced BGP, OSPF and ECMP routing VLAG for Layer 2 fabric Single chip design for improved latency and buffer management Figure 8 Lenovo ThinkSystem NE2572 RackSwitch Switch Solutions utilizing the NE2572 are characterized as follows: Layer 2 solution with VLAG with 28 leaf switches connected to a 400 (2 switch spine) Gbps spine can connect up to 1,568 (28 x (48+8)) server ports with an oversubscription of 4:1 ((25Gx56 servers):400g); if only 25G SFP28 ports are used the oversubscription is 3:1 (25Gx48 servers:400g). This solution is shown in Figure Introduction to - Networking Designs

11 2 x 100/40/25/10 Gbps L3 interfaces from each spine switch to core using VRRP and ECMP NE2572 Switch 1 NE2572 Switch 2 NE2572 Switch 27 NE2572 Switch 28 Four (4) 100 Gbps links from each leaf switch are utilized for an ISL (2 links) and uplink to the spine (2 links). Figure 9 ThinkSystem NE2572 RackSwitch Layer 2 solution with VLAG Each leaf pair has a 400 Gbps VLAG to the spine with a connection to each spine switch from each leaf switch in the pair. NE2572 Layer 2 solution with no leaf VLAG with 28 leaf switches connected to an 80 Gbps spine can up to 1,792 (28 x (48+16)) server ports with an oversubscription of 8:1 ((25Gx64 servers):200g); if only 25G SFP28 ports are used the oversubscription is 6:1 ((25Gx48 servers):200g); at a cost to some redundancy and connections options to the server. This solution is shown in Figure x 100/40/25/10 Gbps L3 interfaces from each spine switch to core using VRRP and ECMP Each leaf switch has an 200 Gbps VLAG to the spine with a connection to each spine switch. NE2572 Switch 1 NE2572 Switch 2 NE2572 Switch 27 NE2572 Switch 28 NE2572 Each leaf switch has two (2) 100 Gbps links in a LAG to the spine. Figure 10 ThinkSystem NE2572 RackSwitch Layer 2 solution with no leaf VLAG 11

12 Layer 3 solution with 30 leaf switches The Layer 3 solutions are all based off of the following architecture diagram and only vary by then number of spine switches that are connected or reserved ports. This solution is shown in Figure 11 on page 12. Switch 1 Up to 6 x Switches 2 x 100/40/25/10 Gbps L3 interfaces from each spine switch to core using VRRP and ECMP Switch n NE2572 Switch 1 NE2572 Switch 2 NE2572 Switch 29 NE2572 Switch 30 There are up to 30 x NE2572 leaf switches in this solution, the available server connections are dependent upon the number of spine switches. Figure 11 ThinkSystem NE2572 RackSwitch Layer 3 solution with 30 leaf switches Table 1 lists the capacities of Lenovo's Layer 3 solution using NE2572 leaf switches. Table 1 Lenovo ThinkSystem NE2572 RackSwitch L3 leaf switch capacities Each leaf switch has an 100 Gbps link to each spine switch. NE2572 Server ports per leaf switch switch quantity speed (Gbps) switch quantity Server quantity Oversubscription ratio Rounded oversubscription ratio :1 2: :5 3: :2 4: :1 5: :1 8:1 Lenovo RackSwitch G8272 Switch The Lenovo RackSwitch G8272 is Lenovo s 1U 10 Gbps Ethernet solution for the leaf switch. The G8272 has the following features that are important for this leaf switch: Layer 2/3 for both routing and switching CNOS for enhanced BGP, OSPF and ECMP routing VLAG for Layer 2 fabric Single chip design for improved latency and buffer management 12 Introduction to - Networking Designs

13 6 QSFP+ ports for 40 Gbps spine connections allowing for a maximum cumulative spine speed of 240 Gbps. The QSFP+ ports not utilized for spine connections can be broken out into 4 x 10 Gigabit Ethernet ports for additional server connections. 48 SFP+ ports for 1/10 Gigabit Ethernet server connections per leaf switch The Lenovo RackSwitch G8272 is shown in Figure 12. Figure 12 Lenovo RackSwitch G8272 Switch Solutions utilizing the G8272 are characterized as follows: Layer 2 solution with VLAG with 28 leaf switches connected to a 160 (2 switch spine) Gbps spine can connect up to 1,568 (28 x (48+8)) server ports with an oversubscription of 4:1 ((10Gx56 servers):160g); if only 10G SFP+ ports are used the oversubscription is 3:1 (10Gx48 servers:160g). This solution is shown in Figure 13 on page x 10/40 Gbps L3 interfaces from each spine switch to core using VRRP and ECMP or G8332 G8272 Switch 1 G8272 Switch 2 G8272 Switch 27 G8272 Switch 28 Four (4) 40 Gbps links from each leaf switch are utilized for an ISL (2 links) and uplink to the spine (2 links). Figure 13 RackSwitch G8272 Layer 2 solution with VLAG Each leaf pair has a 160 Gbps VLAG to the spine with a connection to each spine switch from each leaf switch in the pair. G8272 Layer 2 solution with no leaf VLAG with 28 leaf switches connected to an 80 Gbps spine can up to 1,792 (28 x (48+16)) server ports with an oversubscription of 8:1 ((10Gx64 servers):80g); if only 10G SFP+ ports are used the oversubscription is 6:1 ((10Gx48 servers):80g); at a cost to some redundancy and connections options to the server. This solution is shown in Figure

14 2 x 10/40 Gbps L3 interfaces from each spine switch to core using VRRP and ECMP or G8332 Each leaf switch has an 80 Gbps VLAG to the spine with a connection to each spine switch. G8272 Switch 1 G8272 Switch 2 G8272 Switch 27 G8272 Switch 28 G8272 Each leaf switch has two (2) 40 Gbps links in a LAG to the spine. Figure 14 RackSwitch G8272 Layer 2 solution with no leaf VLAG Layer 3 solution with 30 leaf switches The Layer 3 solutions are all based off of the following architecture diagram and only vary by then number of spine switches that are connected or reserved ports. This solution is shown in Figure 15. Switch 1 Up to 6 x Switches 2 x 10/40 Gbps L3 interfaces from each spine switch to core using VRRP and ECMP Switch n or G8332 G8272 Switch 1 G8272 Switch 2 G8272 Switch 29 G8272 Switch 30 There are up to 30 x G8272 leaf switches in this solution, the available server connections are dependent upon the number of spine switches. Figure 15 RackSwitch G8272 Layer 3 solution with 30 leaf switches Each leaf switch has an 40 Gbps link to each spine switch. Table 2 lists the capacities of Lenovo's Layer 3 solution utilizing G8272 leaf switches. G Introduction to - Networking Designs

15 Table 2 Lenovo RackSwitch G8272 leaf switch capacities Server ports per leaf switch switch quantity speed (Gbps) switch quantity Server quantity Oversubscription ratio Rounded oversubscription ratio :1 2: :5 3: :2 4: :1 5: :1 8:1 Lenovo RackSwitch G8296 Switch The Lenovo RackSwitch G8296 is Lenovo s 2U solution for the leaf switch. The G8296 has the following features that are important for this leaf switch: Layer 2/3 for both routing and switching CNOS for enhanced BGP, OSPF and ECMP routing VLAG for Layer 2 fabric Single chip design for improved latency and buffer management 10 QSFP+ ports for 40 Gbps spine connections allowing for a maximum cumulative spine speed of 400 Gbps. Two of the QSFP+ ports not utilized for spine connections can be broken out into 4 x 10 Gigabit Ethernet ports for eight additional server connections. The remaining QSFP+ ports can be utilized as a single server connection. 86 SFP+ ports for 1/10 Gigabit Ethernet server connections per leaf switch The Lenovo RackSwitch G8296 is shown in Figure 16. Figure 16 Lenovo RackSwitch G8296 Switch Solutions utilizing the G8296 are characterized as follows: Layer 2 solution with VLAG with 28 leaf switches connected to a 160 Gbps spine can connect up to 2,744 (28 x (86+8+4)) server ports with an oversubscription of 6:1 ((10Gx98 servers:160g). This solution is shown in Figure

16 2 x 10/40 Gbps L3 interfaces from each spine switch to core using VRRP and ECMP or G8332 G8296 Switch 1 G8296 Switch 2 G8296 Switch 27 G8296 Switch 28 Four (4) 40 Gbps links from each leaf switch are utilized for an ISL (2 links) and uplink to the spine (2 links). Figure 17 RackSwitch G8296 Layer 2 solution with VLAG (28 leaf switches) Each leaf pair has a 160 Gbps VLAG to the spine with a connection to each spine switch from each leaf switch in the pair. G8296 Layer 2 solution VLAG with 14 leaf switches connected to a 320 Gbps spine by aggregating two QSFP+ ports on each leaf switch can connect up to 1,316 (14 x (86+8)) server ports with an oversubscription of 3:1 ((10Gx94 servers:320g). This solution, shown in Figure 18 on page 16, doubles the spine connections to reduce oversubscription but will also reduce the maximum number of server conneciton possible for the solution. 2 x 10/40 Gbps L3 interfaces from each spine switch to core using VRRP and ECMP or G8332 Each leaf pair has a 320 Gbps VLAG to the spine with a connection to each spine switch from each leaf switch in the pair. G8296 Switch 1 G8296 Switch 2 G8296 Switch 13 G8296 Switch 14 G8296 Four (8) 40 Gbps links from each leaf switch are utilized for an ISL (4 links) and uplink to the spine (4 links). Figure 18 RackSwitch G8296 Layer 2 solution with VLAG (14 leaf switches) 16 Introduction to - Networking Designs

17 Layer 2 solution no leaf VLAG with 30 leaf switches connected to an 80 Gbps spine can up to 2,856 (28 x (86+8+8)) server ports with an oversubscription of 13:1 ((10Gx102 servers:80g) at a cost to redundancy. This solution is shown in Figure x 10/40 Gbps L3 interfaces from each spine switch to core using VRRP and ECMP or G8332 Each leaf switch has an 80 Gbps VLAG to the spine with a connection to each spine switch. G8296 Switch 1 G8296 Switch 2 G8296 Switch 27 G8296 Switch 28 Each leaf switch has two (2) 40 Gbps links in a LAG to the spine. G8296 Figure 19 RackSwitch G8296 Layer 2 solution no leaf VLAG Layer 3 solution with 30 leaf switches The Layer 3 solutions are all based off of the following architecture diagram and only vary by then number of spine switches that are connected or reserved ports. The G8296 supports up to 10 spine switches. This solution is shown in Figure

18 Switch 1 Up to 10 x Switches 2 x 10/40 Gbps L3 interfaces from each spine switch to core using VRRP and ECMP Switch n or G8332 Each leaf switch has an 40 Gbps link to each spine switch. G8296 Switch 1 G8296 Switch 2 G8296 Switch 27 G8296 Switch 28 There are up to 30 x G8296 leaf switches in this solution, the available server connections are dependent upon the number of spine switches. G8296 Figure 20 RackSwitch G8296 Layer 3 solution Table 3 lists the capacities of Lenovo's layer 3 solution utilizing G8296 leaf switches. Table 3 Lenovo RackSwitch G8296 leaf switch capacities Server ports per leaf switch switch quantity speed (Gbps) switch quantity Server quantity Oversubscription ratio Rounded oversubscription ratio :20 2: :2 3: :16 3: :28 3: :1 4: :20 5: :8 6: :4 8: :2 13:1 Lenovo EN4093R Switch for Flex System The Lenovo Flex System Fabric EN4093R 10Gb Scalable Switch is Lenovo s Flex System solution for the leaf switch. The EN4093R has the following features that are important for this leaf switch: Layer 2/3 for both routing and switching 18 Introduction to - Networking Designs

19 ENOS with BGP, OSPF and ECMP routing VLAG for Layer 2 fabric Single chip design for improved latency and buffer management 2 QSFP+ ports for 40 Gbps spine connections allowing for a maximum cumulative spine speed of 80 Gbps. 14 dedicated server facing ports 14 SFP+ ports for 1/10 Gigabit external Ethernet server connections and an Inter-Switch Link (ISL) for use with VLAG The Lenovo Flex System Fabric EN4093R 10Gb Scalable Switch is shown in Figure 21. Figure 21 Lenovo Flex System Fabric EN4093R 10Gb Scalable Switch Solutions utilizing the Flex System Chassis and the EN4093R have some limitations as compared to TOR based solutions. The main limitation is the limited number of 40 Gbps ports restricting this solution to two spine switches. There is also a limited number of servers that can be connected due to the hard wired connections to the Flex System server nodes. Solutions utilizing the EN4093R are characterized as follows: Layer 2 solution with VLAG with 28 leaf switches connected to a 160 (2 switch spine) Gbps spine can connect up to 672 (28 x (14 INT + 10 EXT)) server ports with an oversubscription of 2:1 ((10Gx24 servers:160g). The solution is shown in Figure x 10/40 Gbps L3 interfaces from each spine switch to core using VRRP and ECMP EN4093R Chassis 1/Switch 1 EN4093R Chassis 1/Switch 2 Figure 22 Flex System EN4093R Layer 2 solution with VLAG Each leaf pair has a 160 Gbps VLAG to the spine with a connection to each spine switch from each leaf switch in the pair. EN4093R Chassis 14/Switch 1 EN4093R Chassis 14/Switch 2 The 2 x 40 Gbps links from each EN4093R switch are utilized for uplinks to the spine and 4 to 8 x 10 Gbps EXT links are used for the ISL (2 links). or G8332 EN4093R Layer 2 solution with no leaf VLAG with 30 leaf switches connected to an 80 Gbps spine can up to 784 (28 x (14 INT + 14 EXT)) server ports with an oversubscription of 4:1 19

20 ((10Gx28 servers:80g) at a cost to some redundancy and connections options to the server. The solution is shown in Figure x 10/40 Gbps L3 interfaces from each spine switch to core using VRRP and ECMP or G8332 EN4093R Chassis 1/Switch 1 EN4093R Chassis 1/Switch 2 Each leaf switch has an 80 Gbps VLAG to the spine with a connection to each spine switch. EN4093R Chassis 14/Switch 1 EN4093R Chassis 14/Switch 2 EN4093R The 2 x 40 Gbps links from each EN4093R switch are utilized for uplinks to the spine. Figure 23 Flex System EN4093R Layer 2 solution with no leaf VLAG Layer 3 solution with 30 leaf switches The spine size for Flex System solution is limited to two (2) switches no matter if it is Layer 3 or 3. With this in mind, it is probably best to not involve the complexity of configuring routing for the Flex System spine-leaf. This may only be advantages if a lot of inter VLAN routing is utilized in the solution. The EN40993R L3 architecture is shown in Figure x 10/40 Gbps L3 interfaces from each spine switch to core using VRRP and ECMP Switch 1 Switch 2 or G8332 EN4093R Chassis 1/Switch 1 EN4093R Chassis 1/Switch 2 Each leaf switch has an 80 Gbps VLAG to the spine with a connection to each spine switch. EN4093R Chassis 14/Switch 1 EN4093R Chassis 14/Switch 2 EN4093R The 2 x 40 Gbps links from each EN4093R switch are utilized for uplinks to the spine. Figure 24 Flex System EN4093R Layer 3 solution 20 Introduction to - Networking Designs

21 The connected ports are as follows: 80 Gbps spine (2 switch spine) can connect up to 784 (28 x (14 INT + 14 EXT)) server ports with an oversubscription of 4:1 ((10Gx28 servers:80g) Conclusion Lenovo s Layer 3 spine-leaf architecture provides the best oversubscription ratios with the highest number of server ports. This architecture also provides the ability to connect thousands of servers with low latency single hop connections between the leaf switches. These connections are made over a high speed spine with low congestion as indicated by the low oversubscription numbers. Lenovo s Cloud Network Operating System (CNOS) also targets Layer 3 routing with BGP and OSPF routing protocols tuned for optimal performance. With lower numbers of servers, Lenovo s simple Layer 2 spine-leaf architecture provides good capacities without the complexity of Layer 3 configurations. The Layer 2 solution can also be greatly simplified using Q-in-Q tunneling so that no VLAN configuration is required. In conclusion, Lenovo s spine-leaf Architectures provide both Layer 2 and Layer 3 solutions with high capacities and low congestion. 21

22 Appendix: Lenovo spine-leaf capacities Table 4 provides a convenient reference summarizing the scalability of Lenovo's spine-leaf solutions. With this table you can determine at a glance the number of servers and oversubscription ratios that are possible with each architecture and leaf switch utilized. Table 4 Lenovo spine-leaf architecture capacities switch switch Server ports per leaf switch Server port speed (Gbps) switch quantity speed (Gbps) switch quantity Server quantity Oversubscription ratio Rounded oversubscription ratio & Architecture - L2 with VLAG NE :2 4:1 G8272 /G :2 4:1 G8296 /G :8 6:1 G8296 /G :16 3:1 EN4093R /G :2 2:1 & Architecture - L2 without VLAG NE :1 8:1 G8272 /G :1 8:1 G8296 /G :4 13:1 EN4093R /G :2 4:1 & Architecture - L3 NE :1 2:1 NE :2 4:1 NE :1 8:1 G8272 /G :1 2:1 G8272 /G :2 4:1 G8272 /G :1 8:1 G8296 /G :20 2:1 G8296 /G :16 3:1 G8296 /G :1 4:1 G8296 /G :8 6:1 G8296 /G :2 13:1 EN4093R /G :2 4:1 22 Introduction to - Networking Designs

23 Acronyms BGP Boarder Gateway Protocol CNOS Cloud Network Operating System ECMP Equal Cost Multi-Path Routing ENOS Enterprise Network Operating System Gbps Gigabits per second ISL Inter-Switch Link L2 Layer 2 L2/3 Layer 2 and 3 L3 Layer 3 MAC Media Access Control OSPF Open Shortest Path First RU Rack Unit SPB Shortest Path Bridging TRILL Transparent Interconnection of Lots of Links TOR Top Of Rack VLAG Virtual Link Aggregation VRRP Virtual Redundancy Protocol Change history November 7 update: Added the ThinkSystem 100 GbE spine switch Added the ThinkSystem NE GbE leaf switch Author William Nelson is a Worldwide Technical Sales Leader for Lenovo Networking. He joined Lenovo from IBM and BNT and has over 30 years of networking experience. He was one of the four founders of BNT and an early member of Centillion Networks and Alteon Web Systems. He is an evangelist for Lenovo's Networking products to the sales and customer communities and is the key voice of the customer to the networking product and engineering teams. Bill graduated from Virginia Tech with a BS in Biochemistry and University of Maryland with a BS in Computer Science. Thanks to the following people for their contributions to this project: Jim Whitten, WW Product Marketing Manager for Lenovo Networking David Watts, Lenovo Press 23

24 Notices Lenovo may not offer the products, services, or features discussed in this document in all countries. Consult your local Lenovo representative for information on the products and services currently available in your area. Any reference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any Lenovo intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any other product, program, or service. Lenovo may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to: Lenovo (United States), Inc Think Place - Building One Morrisville, NC U.S.A. Attention: Lenovo Director of Licensing LENOVO PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. Lenovo may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. The information contained in this document does not affect or change Lenovo product specifications or warranties. Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties. All information contained in this document was obtained in specific environments and is presented as an illustration. The result obtained in other operating environments may vary. Lenovo may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Any references in this publication to non-lenovo Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was determined in a controlled environment. Therefore, the result obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment. Copyright Lenovo All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by Global Services Administration (GSA) ADP Schedule Contract 24

25 This document was created or updated on November 10, Send us your comments via the Rate & Provide Feedback form found at Trademarks Lenovo, the Lenovo logo, and For Those Who Do are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. These and other Lenovo trademarked terms are marked on their first occurrence in this information with the appropriate symbol ( or ), indicating US registered or common law trademarks owned by Lenovo at the time this information was published. Such trademarks may also be registered or common law trademarks in other countries. A current list of Lenovo trademarks is available on the Web at The following terms are trademarks of Lenovo in the United States, other countries, or both: BNT Flex System Lenovo RackSwitch Lenovo(logo) ThinkSystem The following terms are trademarks of other companies: Other company, product, or service names may be trademarks or service marks of others. 25

Intel Xeon Scalable Family Balanced Memory Configurations

Intel Xeon Scalable Family Balanced Memory Configurations Front cover Intel Xeon Scalable Family Balanced Memory Configurations Last Update: 20 November 2017 Demonstrates three balanced memory guidelines for Intel Xeon Scalable processors Compares the performance

More information

Maximizing System x and ThinkServer Performance with a Balanced Memory Configuration

Maximizing System x and ThinkServer Performance with a Balanced Memory Configuration Front cover Maximizing System x and ThinkServer Performance with a Balanced Configuration Last Update: October 2017 Introduces three balanced memory guidelines for Intel Xeon s Compares the performance

More information

An Introduction to NIC Teaming with Lenovo Networking Switches

An Introduction to NIC Teaming with Lenovo Networking Switches Front cover An Introduction to NIC Teaming with Lenovo Networking Switches Shows how Network Interface Card (NIC) teaming can be configured Includes examples for Linux, Windows, and VMware Describes how

More information

Introduction to PCI Express Positioning Information

Introduction to PCI Express Positioning Information Introduction to PCI Express Positioning Information Main PCI Express is the latest development in PCI to support adapters and devices. The technology is aimed at multiple market segments, meaning that

More information

Broadcom 10Gb 2-Port and 4-Port Ethernet Expansion Cards (CFFh) for IBM BladeCenter (Withdrawn) Product Guide

Broadcom 10Gb 2-Port and 4-Port Ethernet Expansion Cards (CFFh) for IBM BladeCenter (Withdrawn) Product Guide Broadcom 10Gb 2-Port and 4-Port Ethernet Expansion Cards (CFFh) for IBM BladeCenter (Withdrawn) Product Guide IBM is committed to offering both function and flexibility to our clients through our products.

More information

Flex System FC5024D 4-port 16Gb FC Adapter Lenovo Press Product Guide

Flex System FC5024D 4-port 16Gb FC Adapter Lenovo Press Product Guide Flex System FC5024D 4-port 16Gb FC Adapter Lenovo Press Product Guide The network architecture on the Flex System platform is designed to address network challenges, giving you a scalable way to integrate,

More information

2/4 Port Ethernet Expansion Card (CFFh) for IBM BladeCenter Product Guide

2/4 Port Ethernet Expansion Card (CFFh) for IBM BladeCenter Product Guide 2/4 Port Ethernet Expansion Card (CFFh) for IBM BladeCenter Product Guide The IBM 2/4 Port Ethernet Expansion Card (CFFh) for IBM BladeCenter is the perfect example of IBM's goal to meet user requirements

More information

IBM BladeCenter Layer 2-7 Gigabit Ethernet Switch Module (Withdrawn) Product Guide

IBM BladeCenter Layer 2-7 Gigabit Ethernet Switch Module (Withdrawn) Product Guide IBM BladeCenter Layer 2-7 Gigabit Ethernet Switch Module (Withdrawn) Product Guide The IBM BladeCenter Layer 2-7 Gigabit Ethernet Switch Module serves as a switching and routing fabric for the IBM BladeCenter

More information

Cisco Systems 4 Gb 20-port and 10-port Fibre Channel Switch Modules for BladeCenter

Cisco Systems 4 Gb 20-port and 10-port Fibre Channel Switch Modules for BladeCenter Cisco Systems 4 Gb 20-port and 10-port Fibre Channel Switch Modules for BladeCenter Product Guide The Cisco Systems 4 Gb 20-port and 10-port Fibre Channel Switch Modules for BladeCenter provide highperformance

More information

Brocade 20-port 8Gb SAN Switch Modules for BladeCenter

Brocade 20-port 8Gb SAN Switch Modules for BladeCenter Brocade 20-port 8Gb SAN Switch Modules for BladeCenter Product Guide The Brocade Enterprise 20-port, 20-port, and 10-port 8 Gb SAN Switch Modules for BladeCenter deliver embedded Fibre Channel switching

More information

Understanding the Performance Benefits of MegaRAID FastPath with Lenovo Servers

Understanding the Performance Benefits of MegaRAID FastPath with Lenovo Servers Front cover Understanding the Performance Benefits of MegaRAID FastPath with Lenovo Servers Introduces the SSD Performance Accelerator for Lenovo servers Describes the performance gains from using MegaRAID

More information

Flex System FC port 16Gb FC Adapter Lenovo Press Product Guide

Flex System FC port 16Gb FC Adapter Lenovo Press Product Guide Flex System FC5022 2-port 16Gb FC Adapter Lenovo Press Product Guide The network architecture on the Flex System platform has been specifically designed to address network challenges, giving you a very

More information

Lenovo RAID Introduction Reference Information

Lenovo RAID Introduction Reference Information Lenovo RAID Introduction Reference Information Using a Redundant Array of Independent Disks (RAID) to store data remains one of the most common and cost-efficient methods to increase server's storage performance,

More information

Using Read Intensive SSDs with Lenovo Storage V Series and IBM Storwize for Lenovo

Using Read Intensive SSDs with Lenovo Storage V Series and IBM Storwize for Lenovo Front cover Using Read Intensive SSDs with Lenovo Storage V Series and IBM Storwize for Lenovo Introduces Read Intensive SSD Identification on Lenovo Storage V-series product family Highlights the tips

More information

Introduction to Windows Server 2016 Hyper-V Discrete Device Assignment

Introduction to Windows Server 2016 Hyper-V Discrete Device Assignment Front cover Introduction to Windows Server 2016 Hyper-V Discrete Device Assignment Introduces the new PCIe Device Passthrough feature of Microsoft Windows Server 2016 Describes how to make PCIe devices

More information

BladeCenter HS21 XM Memory Configurations Positioning Information (withdrawn product)

BladeCenter HS21 XM Memory Configurations Positioning Information (withdrawn product) BladeCenter HS21 XM Memory Configurations Positioning Information (withdrawn product) BladeCenter HS21 XM Memory Configurations (withdrawn product) 1 Memory DIMM placement The logical memory DIMM configuration

More information

Flex System FC port 8Gb FC Adapter Lenovo Press Product Guide

Flex System FC port 8Gb FC Adapter Lenovo Press Product Guide Flex System FC3172 2-port 8Gb FC Adapter Lenovo Press Product Guide The Flex System FC3172 2-port 8Gb FC Adapter enables high-speed access for Flex System compute nodes to connect to a Fibre Channel storage

More information

Flex System EN port 10Gb Ethernet Adapter Product Guide

Flex System EN port 10Gb Ethernet Adapter Product Guide Flex System EN4132 2-port 10Gb Ethernet Adapter Product Guide The Flex System EN4132 2-port 10Gb Ethernet Adapter delivers high-bandwidth and industry-leading Ethernet connectivity for performance-driven

More information

Flex System EN port 1Gb Ethernet Adapter Product Guide

Flex System EN port 1Gb Ethernet Adapter Product Guide Flex System EN202 -port 1Gb Ethernet Adapter Product Guide The Flex System EN202 -port 1Gb Ethernet Adapter is a quad-port Gigabit Ethernet network adapter. When it is combined with the Flex System EN2092

More information

Brocade 10Gb CNA for IBM System x (Withdrawn) Product Guide

Brocade 10Gb CNA for IBM System x (Withdrawn) Product Guide Brocade 10Gb CNA for IBM System x (Withdrawn) Product Guide The Brocade 10Gb CNA for IBM System x is a PCI Express 2.0 x8 10Gb Converged Network Adapter with two SFP+ cages. The adapter can support either

More information

IBM Ethernet Switch J48E

IBM Ethernet Switch J48E IBM Ethernet Switch J48E The IBM J48E Ethernet Switches with Virtual Chassis technology combine the high availability (HA) and carrier-class reliability of modular systems with the economics and flexibility

More information

Comparing the IBM eserver xseries 440 with the xseries 445 Positioning Information

Comparing the IBM eserver xseries 440 with the xseries 445 Positioning Information Comparing the IBM eserver xseries 440 with the xseries 445 Positioning Information Main Feature x440 server x445 server IBM chipset First generation XA-32 Second generation XA-32 SMP scalability Support

More information

IBM 1735 Rack-Based Local Console Switches (Withdrawn) Product Guide

IBM 1735 Rack-Based Local Console Switches (Withdrawn) Product Guide IBM 1735 Rack-Based Local Console Switches (Withdrawn) Product Guide The family of IBM rack-based local console switches is designed to provide exceptional scalability and flexibility in managing data

More information

Lenovo Flex System EN Gb Ethernet Pass-thru Product Guide

Lenovo Flex System EN Gb Ethernet Pass-thru Product Guide Lenovo Flex System EN4091 10Gb Ethernet Pass-thru Product Guide The Lenovo Flex System EN4091 10Gb Ethernet Pass-thru offers easy connectivity of the Flex System chassis to any external network infrastructure.

More information

Broadcom NetXtreme Gigabit Ethernet Adapters Product Guide

Broadcom NetXtreme Gigabit Ethernet Adapters Product Guide Broadcom NetXtreme Gigabit Ethernet Adapters Product Guide The Broadcom NetXtreme Gigabit Ethernet Adapters are a family of high performance PCI Express adapters. The adapters are available with either

More information

N2225 and N2226 SAS/SATA HBAs for System x Lenovo Press Product Guide

N2225 and N2226 SAS/SATA HBAs for System x Lenovo Press Product Guide N2225 and N2226 SAS/SATA HBAs for System x Lenovo Press Product Guide The N2225 and N2226 SAS/SATA HBAs for System x are low-cost, high-performance host bus adapters for high-performance connectivity between

More information

Flex System FC port and FC port 16Gb FC Adapters Lenovo Press Product Guide

Flex System FC port and FC port 16Gb FC Adapters Lenovo Press Product Guide Flex System FC5052 2-port and FC5054 4-port 16Gb FC Adapters Lenovo Press Product Guide The Flex System FC5052 2-port and FC5054 4-port 16Gb FC Adapters enable the highest FC speed access for Flex System

More information

Emulex 10GbE Virtual Fabric Adapter II for IBM BladeCenter IBM Redbooks Product Guide

Emulex 10GbE Virtual Fabric Adapter II for IBM BladeCenter IBM Redbooks Product Guide Emulex 10GbE Virtual Fabric Adapter II for IBM BladeCenter IBM Redbooks Product Guide The Emulex 10 GbE Virtual Fabric Adapter II and Emulex 10 GbE Virtual Fabric Adapter Advanced II are enhancements to

More information

IBM High IOPS Modular Adapters (Withdrawn) Product Guide

IBM High IOPS Modular Adapters (Withdrawn) Product Guide IBM High IOPS Modular Adapters (Withdrawn) Product Guide The new family of IBM High IOPS Modular Adapters is the ultimate performance solution for embedded direct-attached storage for IBM System x, IBM

More information

Designing a Reference Architecture for Virtualized Environments Using IBM System Storage N series IBM Redbooks Solution Guide

Designing a Reference Architecture for Virtualized Environments Using IBM System Storage N series IBM Redbooks Solution Guide Designing a Reference Architecture for Virtualized Environments Using IBM System Storage N series IBM Redbooks Solution Guide The IBM System Storage N series Reference Architecture provides deployment

More information

Solution Guide: Flex System Solution for Oracle RAC

Solution Guide: Flex System Solution for Oracle RAC Bryan Reese Ajay Dholakia Thomas Parker Solution Guide: Flex System Solution for Oracle RAC Solution Reference Number: BDARACFX043 Contents Solution Guide: Flex System Solution for Oracle RAC..............................

More information

SAS 2.5-inch Hybrid Hard Drives for System x Product Guide

SAS 2.5-inch Hybrid Hard Drives for System x Product Guide SAS 2.5-inch Hybrid Hard Drives for System x Product Guide The IBM SAS 2.5-inch Hybrid hard disk drives (HDDs) for System x provide cost-effective performance and density by combining a cache of NAND flash

More information

Flex System IB port FDR InfiniBand Adapter Lenovo Press Product Guide

Flex System IB port FDR InfiniBand Adapter Lenovo Press Product Guide Flex System IB6132 2-port FDR InfiniBand Adapter Lenovo Press Product Guide The Flex System IB6132 2-port FDR InfiniBand Adapter delivers low latency and high bandwidth for performance-driven server clustering

More information

OSIG Change History Article

OSIG Change History Article OSIG Change History Article Change history The OSIG has moved The OSIG is now available as a web application. See http://lenovopress.com/osig 21 September 2016 Windows Server 2016 is Certified on x3850

More information

Lenovo exflash DDR3 Storage DIMMs Product Guide

Lenovo exflash DDR3 Storage DIMMs Product Guide Lenovo exflash DDR3 Storage DIMMs Product Guide exflash memory-channel storage is the newest innovative flash memory technology from Lenovo, first introduced with System x3850 X6 and x3950 X6 servers.

More information

IBM Flex System FC5024D 4-port 16Gb FC Adapter IBM Redbooks Product Guide

IBM Flex System FC5024D 4-port 16Gb FC Adapter IBM Redbooks Product Guide IBM Flex System FC5024D 4-port 16Gb FC Adapter IBM Redbooks Product Guide The network architecture on the IBM Flex System platform is designed to address network challenges, giving you a scalable way to

More information

IBM High IOPS MLC Adapters Product Guide

IBM High IOPS MLC Adapters Product Guide IBM High IOPS MLC Adapters Product Guide The IBM 365GB, 785GB and 1.2TB MLC Mono and 2.4TB MLC Duo High IOPS Adapters for IBM System x, IBM BladeCenter, and IBM Flex System are second-generation adapters

More information

ServeRAID C100 and C105 Product Guide

ServeRAID C100 and C105 Product Guide ServeRAID C100 and C105 Product Guide The ServeRAID C100 and ServeRAID C105 are integrated SATA controllers with software RAID capabilities. They are a cost-effective way to provide reliability, performance,

More information

Intel I350 Gigabit Ethernet Adapters Product Guide

Intel I350 Gigabit Ethernet Adapters Product Guide Intel I350 Gigabit Ethernet Adapters Product Guide Based on the Intel I350 Gigabit Ethernet adapters from Lenovo build on Intel's history of delivering Ethernet products with flexible design and robust

More information

2-Port 40 Gb InfiniBand Expansion Card (CFFh) for IBM BladeCenter IBM BladeCenter at-a-glance guide

2-Port 40 Gb InfiniBand Expansion Card (CFFh) for IBM BladeCenter IBM BladeCenter at-a-glance guide 2-Port 40 Gb InfiniBand Expansion Card (CFFh) for IBM BladeCenter IBM BladeCenter at-a-glance guide The 2-Port 40 Gb InfiniBand Expansion Card (CFFh) for IBM BladeCenter is a dual port InfiniBand Host

More information

IBM Flex System FC port 8Gb FC Adapter IBM Redbooks Product Guide

IBM Flex System FC port 8Gb FC Adapter IBM Redbooks Product Guide IBM Flex System FC3172 2-port 8Gb FC Adapter IBM Redbooks Product Guide The IBM Flex System FC3172 2-port 8Gb FC Adapter enables high-speed access for IBM Flex System compute nodes to connect to a Fibre

More information

Architecting Data Center Networks in the era of Big Data and Cloud

Architecting Data Center Networks in the era of Big Data and Cloud Architecting Data Center Networks in the era of Big Data and Cloud Spring Interop May 2012 VIDEO of this session: http://bradhedlund.com/?p=3912 Two approaches to DC Networking THE SAME OLD Centralized,

More information

Networking solution for consolidated IT infrastructure

Networking solution for consolidated IT infrastructure Networking solution for consolidated IT infrastructure Timo Lonka timo@extremenetworks.com Topics 1.The New Extreme 2. IP Storage and HCI Networking 3. Agile Data Center Architecture 4. Case study: Ficolo

More information

Continuous Availability with the IBM DB2 purescale Feature IBM Redbooks Solution Guide

Continuous Availability with the IBM DB2 purescale Feature IBM Redbooks Solution Guide Continuous Availability with the IBM DB2 purescale Feature IBM Redbooks Solution Guide Designed for organizations that run online transaction processing (OLTP) applications, the IBM DB2 purescale Feature

More information

IBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide

IBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide IBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide The IBM UPS5000 HV is a 5 KVA rack-mountable uninterruptible power supply (UPS) that utilizes advanced backup power technology

More information

Brocade Ethernet Fabrics

Brocade Ethernet Fabrics Brocade Ethernet Fabrics Brocade 9 June 2015 On-Demand Data Center Network Technologies Strategic focus areas FIBRE CHANNEL FABRICS ETHERNET FABRICS CORE ROUTING SDN NFV CLOUD ORCHESTRATION 2015 Brocade

More information

Using the IBM DS8870 in an OpenStack Cloud Environment IBM Redbooks Solution Guide

Using the IBM DS8870 in an OpenStack Cloud Environment IBM Redbooks Solution Guide Using the IBM DS8870 in an OpenStack Cloud Environment IBM Redbooks Solution Guide OpenStack is being developed as an industry standard cloud-computing project. It was started by Rackspace Cloud and NASA

More information

IBM FlashSystem V Quick Start Guide IBM GI

IBM FlashSystem V Quick Start Guide IBM GI IBM FlashSystem V9000 7.7 Quick Start Guide IBM GI13-2894-04 Edition notice This edition applies to IBM FlashSystem V9000 7.7 and to all subsequent releases and modifications until otherwise indicated

More information

Mellanox Virtual Modular Switch

Mellanox Virtual Modular Switch WHITE PAPER July 2015 Mellanox Virtual Modular Switch Introduction...1 Considerations for Data Center Aggregation Switching...1 Virtual Modular Switch Architecture - Dual-Tier 40/56/100GbE Aggregation...2

More information

IBM Spectrum NAS Version Network Guide IBM SC

IBM Spectrum NAS Version Network Guide IBM SC IBM Spectrum NAS Version 1.7.0.0 Network Guide IBM SC27-9231-00 IBM Spectrum NAS is a Software-defined storage solution that provides file storage and offers an active/active storage solution to the end

More information

Emulex 8Gb Fibre Channel Single-port and Dual-port HBAs for IBM System x IBM System x at-a-glance guide

Emulex 8Gb Fibre Channel Single-port and Dual-port HBAs for IBM System x IBM System x at-a-glance guide Emulex 8Gb Fibre Channel Single-port and Dual-port HBAs for IBM System x IBM System x at-a-glance guide Streamlined installation and management, plus unrivaled scalability and industry-leading virtualization

More information

Lenovo ThinkSystem NE Release Notes. For Lenovo Cloud Network Operating System 10.7

Lenovo ThinkSystem NE Release Notes. For Lenovo Cloud Network Operating System 10.7 Lenovo ThinkSystem NE10032 Release Notes For Lenovo Cloud Network Operating System 10.7 Note: Before using this information and the product it supports, read the general information in the Safety information

More information

ServeRAID M5000 Series Performance Accelerator Key for System x Product Guide

ServeRAID M5000 Series Performance Accelerator Key for System x Product Guide ServeRAID M5000 Series Performance Accelerator Key for System x Product Guide The ServeRAID M5000 Series Performance Accelerator Key for System x enables performance enhancements needed by emerging SSD

More information

BGP IN THE DATA CENTER

BGP IN THE DATA CENTER BGP IN THE DATA CENTER A PACKET DESIGN E-BOOK Contents Page 3 : BGP the Savior Page 4 : Traditional Data Center Architecture Traffic Flows Scalability Spanning Tree Protocol (STP) Page 6 : CLOS Architecture

More information

IBM Flex System FC port 16Gb FC Adapter Lenovo Product Guide

IBM Flex System FC port 16Gb FC Adapter Lenovo Product Guide IBM Flex System FC5172 2-port 16Gb FC Adapter Lenovo Product Guide The IBM Flex System FC5172 2-port 16Gb FC Adapter enables high-speed access for IBM Flex System compute nodes to connect to a Fibre Channel

More information

IBM RDX Removable Disk Backup Solution (Withdrawn) Product Guide

IBM RDX Removable Disk Backup Solution (Withdrawn) Product Guide IBM RDX Removable Disk Backup Solution (Withdrawn) Product Guide The new IBM RDX removable disk backup solution is designed to reliably and cost-effectively help protect your business's valuable assets.

More information

ServeRAID-MR10i SAS/SATA Controller IBM System x at-a-glance guide

ServeRAID-MR10i SAS/SATA Controller IBM System x at-a-glance guide ServeRAID-MR10i SAS/SATA Controller IBM System x at-a-glance guide The ServeRAID-MR10i SAS/SATA Controller is a low-cost PCI Express RAID controller for Internal System RAID 0, 1, 10, 5, 50, 6, and 60.

More information

Lenovo ThinkSystem NE Release Notes. For Lenovo Cloud Network Operating System 10.6

Lenovo ThinkSystem NE Release Notes. For Lenovo Cloud Network Operating System 10.6 Lenovo ThinkSystem NE10032 Release Notes For Lenovo Cloud Network Operating System 10.6 Note: Before using this information and the product it supports, read the general information in the Safety information

More information

Lenovo LTO Generation 6 (LTO6) Internal SAS Tape Drive Product Guide

Lenovo LTO Generation 6 (LTO6) Internal SAS Tape Drive Product Guide Lenovo LTO Generation 6 (LTO6) Internal SAS Tape Drive Product Guide The Half-High LTO Generation 6 (LTO6) SAS Tape Drive is a high-performance, high-capacity data-storage device that is designed to back

More information

IBM Flex System EN Gb Ethernet Pass-thru Module IBM Redbooks Product Guide

IBM Flex System EN Gb Ethernet Pass-thru Module IBM Redbooks Product Guide IBM Flex System EN4091 10Gb Ethernet Pass-thru Module IBM Redbooks Product Guide The IBM Flex System EN4091 10Gb Ethernet Pass-thru Module offers easy connectivity of the IBM Flex System Enterprise Chassis

More information

IBM FlashSystem V MTM 9846-AC3, 9848-AC3, 9846-AE2, 9848-AE2, F, F. Quick Start Guide IBM GI

IBM FlashSystem V MTM 9846-AC3, 9848-AC3, 9846-AE2, 9848-AE2, F, F. Quick Start Guide IBM GI IBM FlashSystem V9000 7.8.0 MTM 9846-AC3, 9848-AC3, 9846-AE2, 9848-AE2, 9846-92F, 9848-92F Quick Start Guide IBM GI13-2894-06 Edition notice This edition applies to IBM FlashSystem V9000 7.8.0 and to all

More information

Dell EMC. VxBlock Systems for VMware NSX 6.3 Architecture Overview

Dell EMC. VxBlock Systems for VMware NSX 6.3 Architecture Overview Dell EMC VxBlock Systems for VMware NSX 6.3 Architecture Overview Document revision 1.1 March 2018 Revision history Date Document revision Description of changes March 2018 1.1 Updated the graphic in Logical

More information

Hardware Replacement Guide Lenovo 3000 J Series. Types 8453, 8454, 8455, 8458, 8459, 8460

Hardware Replacement Guide Lenovo 3000 J Series. Types 8453, 8454, 8455, 8458, 8459, 8460 Hardware Replacement Guide Lenovo 3000 J Series Types 8453, 8454, 8455, 8458, 8459, 8460 Lenovo 3000 J Series First Edition (December 2005) Copyright Lenovo 2005. Portions Copyright International Business

More information

VIRTUAL CLUSTER SWITCHING SWITCHES AS A CLOUD FOR THE VIRTUAL DATA CENTER. Emil Kacperek Systems Engineer Brocade Communication Systems.

VIRTUAL CLUSTER SWITCHING SWITCHES AS A CLOUD FOR THE VIRTUAL DATA CENTER. Emil Kacperek Systems Engineer Brocade Communication Systems. VIRTUAL CLUSTER SWITCHING SWITCHES AS A CLOUD FOR THE VIRTUAL DATA CENTER Emil Kacperek Systems Engineer Brocade Communication Systems Mar, 2011 2010 Brocade Communications Systems, Inc. Company Proprietary

More information

1 UPDATING GCM16, GCM32 (1754D1X, 1754D2X) FIRMWARE

1 UPDATING GCM16, GCM32 (1754D1X, 1754D2X) FIRMWARE Contents 1 UPDATING GCM16, GCM32 (1754D1X, 1754D2X) FIRMWARE... 1 2 CHANGE HISTORY FOR EMERSON_FW_GCM16_GCM32_V1.26.1.23978... 2 2.1 ENHANCEMENTS... 2 2.2 PROBLEMS FIXED... 3 3 UPDATE PROCEDURE... 4 3.1

More information

Hardware Replacement Guide

Hardware Replacement Guide Hardware Replacement Guide Types 6491, 8013, 8702, 8706 Types 8716, 8970, 8972, 8976 Types 8980, 8982, 8986, 8992 Types 8994, 9266, 9276, 9278 Types 9282, 9286, 9288, 9374 Types 9378, 9380, 9384, 9628

More information

IBM Flex System EN Gb Ethernet Switch IBM Redbooks Product Guide

IBM Flex System EN Gb Ethernet Switch IBM Redbooks Product Guide IBM Flex System EN6131 40Gb Ethernet Switch IBM Redbooks Product Guide The IBM Flex System EN6131 40Gb Ethernet Switch in conjunction with the EN6132 40Gb Ethernet Adapter offer the performance that you

More information

IBM emessage Version 8.x and higher. Account Startup Overview

IBM emessage Version 8.x and higher.  Account Startup Overview IBM emessage Version 8.x and higher Email Account Startup Overview Note Before using this information and the product it supports, read the information in Notices on page 3. This edition applies to all

More information

Technical Brief. Achieving a Scale-Out IP Fabric with the Adaptive Cloud Fabric Architecture.

Technical Brief. Achieving a Scale-Out IP Fabric with the Adaptive Cloud Fabric Architecture. Technical Brief Achieving a Scale-Out IP Fabric with the Adaptive Cloud Fabric Architecture www.pluribusnetworks.com Terminology Reference This is a glossary of acronyms and terms used throughout this

More information

ServeRAID H1110 SAS/SATA Controller Product Guide

ServeRAID H1110 SAS/SATA Controller Product Guide ServeRAID H1110 SAS/SATA Controller Product Guide The ServeRAID H1110 SAS/SATA Controller for System x offers a low-cost enterprise-grade RAID solution for internal HDDs and integrates popular SAS technology

More information

IBM Flex System EN port 10Gb Ethernet Adapter IBM Redbooks Product Guide

IBM Flex System EN port 10Gb Ethernet Adapter IBM Redbooks Product Guide IBM Flex System EN4132 2-port 10Gb Ethernet Adapter IBM Redbooks Product Guide The IBM Flex System EN4132 2-port 10Gb Ethernet Adapter delivers high-bandwidth and industry-leading Ethernet connectivity

More information

Cloud Data Center Architecture Guide

Cloud Data Center Architecture Guide Cloud Data Center Architecture Guide Modified: 2018-08-21 Juniper Networks, Inc. 1133 Innovation Way Sunnyvale, California 94089 USA 408-745-2000 www.juniper.net Juniper Networks, the Juniper Networks

More information

Implementing IBM Easy Tier with IBM Real-time Compression IBM Redbooks Solution Guide

Implementing IBM Easy Tier with IBM Real-time Compression IBM Redbooks Solution Guide Implementing IBM Easy Tier with IBM Real-time Compression IBM Redbooks Solution Guide Overview IBM Easy Tier is a performance function that automatically and non-disruptively migrates frequently accessed

More information

Migrate from Cisco Catalyst 6500 Series Switches to Cisco Nexus 9000 Series Switches

Migrate from Cisco Catalyst 6500 Series Switches to Cisco Nexus 9000 Series Switches Migration Guide Migrate from Cisco Catalyst 6500 Series Switches to Cisco Nexus 9000 Series Switches Migration Guide November 2013 2013 Cisco and/or its affiliates. All rights reserved. This document is

More information

ServeRAID M5015 and M5014 SAS/SATA Controllers Product Guide

ServeRAID M5015 and M5014 SAS/SATA Controllers Product Guide ServeRAID M5015 and M5014 SAS/SATA Controllers Product Guide The ServeRAID M5015 and ServeRAID M5014 SAS/SATA Controllers for System x are the next-generation 6 Gbps SAS 2.0 RAID controllers. The adapters

More information

SAN Design Best Practices for the Dell PowerEdge M1000e Blade Enclosure and EqualLogic PS Series Storage (1GbE) A Dell Technical Whitepaper

SAN Design Best Practices for the Dell PowerEdge M1000e Blade Enclosure and EqualLogic PS Series Storage (1GbE) A Dell Technical Whitepaper Dell EqualLogic Best Practices Series SAN Design Best Practices for the Dell PowerEdge M1000e Blade Enclosure and EqualLogic PS Series Storage (1GbE) A Dell Technical Whitepaper Storage Infrastructure

More information

Lenovo 42U 1200mm Deep Racks Product Guide

Lenovo 42U 1200mm Deep Racks Product Guide Lenovo 42U 1200mm Deep Racks Product Guide Lenovo 42U 1200 mm Deep Static and Dynamic Rack offerings are industry-standard 19-inch server cabinets that are designed for high availability server environments.

More information

Best practices. Starting and stopping IBM Platform Symphony Developer Edition on a two-host Microsoft Windows cluster. IBM Platform Symphony

Best practices. Starting and stopping IBM Platform Symphony Developer Edition on a two-host Microsoft Windows cluster. IBM Platform Symphony IBM Platform Symphony Best practices Starting and stopping IBM Platform Symphony Developer Edition on a two-host Microsoft Windows cluster AjithShanmuganathan IBM Systems & Technology Group, Software Defined

More information

QLogic BS21, , and InfiniBand Switches IBM Power at-a-glance guide

QLogic BS21, , and InfiniBand Switches IBM Power at-a-glance guide QLogic 12200-BS21, 12800-040, and 12800-180 InfiniBand Switches IBM Power at-a-glance guide InfiniBand is an industry-standard high-performance interconnect for clusters and enterprise grids. This industry-standard

More information

Introduction. Network Architecture Requirements of Data Centers in the Cloud Computing Era

Introduction. Network Architecture Requirements of Data Centers in the Cloud Computing Era Massimiliano Sbaraglia Network Engineer Introduction In the cloud computing era, distributed architecture is used to handle operations of mass data, such as the storage, mining, querying, and searching

More information

Brocade Converged 10GbE Switch Module for BladeCenter Product Guide

Brocade Converged 10GbE Switch Module for BladeCenter Product Guide Brocade Converged 10GbE Switch Module for BladeCenter Product Guide The Brocade Converged 10GbE Switch Module and Brocade 2-Port 10Gb Converged Network Adapter are part of a leading Converged Ethernet

More information

Lenovo ThinkSystem NE1032/NE1032T/NE1072T. Release Notes. For Lenovo Cloud Network Operating System 10.6

Lenovo ThinkSystem NE1032/NE1032T/NE1072T. Release Notes. For Lenovo Cloud Network Operating System 10.6 Lenovo ThinkSystem NE1032/NE1032T/NE1072T Release Notes For Lenovo Cloud Network Operating System 10.6 Note: Before using this information and the product it supports, read the general information in the

More information

Platform LSF Version 9 Release 1.3. Migrating on Windows SC

Platform LSF Version 9 Release 1.3. Migrating on Windows SC Platform LSF Version 9 Release 1.3 Migrating on Windows SC27-5317-03 Platform LSF Version 9 Release 1.3 Migrating on Windows SC27-5317-03 Note Before using this information and the product it supports,

More information

Network Design Considerations for Grid Computing

Network Design Considerations for Grid Computing Network Design Considerations for Grid Computing Engineering Systems How Bandwidth, Latency, and Packet Size Impact Grid Job Performance by Erik Burrows, Engineering Systems Analyst, Principal, Broadcom

More information

Getting Started with InfoSphere Streams Quick Start Edition (VMware)

Getting Started with InfoSphere Streams Quick Start Edition (VMware) IBM InfoSphere Streams Version 3.2 Getting Started with InfoSphere Streams Quick Start Edition (VMware) SC19-4180-00 IBM InfoSphere Streams Version 3.2 Getting Started with InfoSphere Streams Quick Start

More information

Lenovo XClarity Essentials UpdateXpress User Guide

Lenovo XClarity Essentials UpdateXpress User Guide Lenovo XClarity Essentials UpdateXpress User Guide Version 2.2.0 Note Before using this documentation and the products it supports, read the information in Appendix B Notices on page 19. This edition applies

More information

HP0-Y50. Architecting HP FlexNetwork Solutions.

HP0-Y50. Architecting HP FlexNetwork Solutions. HP HP0-Y50 Architecting HP FlexNetwork Solutions http://killexams.com/exam-detail/hp0-y50 between servers distributed across the data center Answer: D QUESTION: 92 A company experienced a denial of service

More information

SATA 1.8-inch and 2.5-inch MLC Enterprise SSDs for System x Product Guide

SATA 1.8-inch and 2.5-inch MLC Enterprise SSDs for System x Product Guide SATA 1.8-inch and 2.5-inch MLC Enterprise SSDs for System x Product Guide The SATA 1.8-inch and 2.5-inch MLC Enterprise solid-state drives (SSDs) for System x employ enterprise MLC NAND technology to bring

More information

Implementing Disk Encryption on System x Servers with IBM Security Key Lifecycle Manager Solution Guide

Implementing Disk Encryption on System x Servers with IBM Security Key Lifecycle Manager Solution Guide Implementing Disk Encryption on System x Servers with IBM Security Key Lifecycle Manager Solution Guide Securing sensitive client and company data is becoming an IT task of paramount importance. Often

More information

Using application properties in IBM Cúram Social Program Management JUnit tests

Using application properties in IBM Cúram Social Program Management JUnit tests Using application properties in IBM Cúram Social Program Management JUnit tests Erika Grine (Erika.Grine@ie.ibm.com) 8 June 2015 Senior Software Engineer, IBM Cúram Social Program Management group IBM

More information

IBM Cloud Object Storage System Version Time Synchronization Configuration Guide IBM DSNCFG_ K

IBM Cloud Object Storage System Version Time Synchronization Configuration Guide IBM DSNCFG_ K IBM Cloud Object Storage System Version 3.13.6 Time Synchronization Configuration Guide IBM DSNCFG_007-20151009K This edition applies to IBM Cloud Object Storage System and is valid until replaced by new

More information

Lenovo XClarity Provisioning Manager User Guide

Lenovo XClarity Provisioning Manager User Guide Lenovo XClarity Provisioning Manager User Guide Fifth Edition (October 2018) Copyright Lenovo 2017, 2018. LIMITED AND RESTRICTED RIGHTS NOTICE: If data or software is delivered pursuant to a General Services

More information

Introduction to Windows Server 2016 Nano Server

Introduction to Windows Server 2016 Nano Server Front cover Introduction to Windows Server 2016 Nano Server Introduces this new feature of Microsoft Windows Server 2016 Describes how to create and manage these low-footprint servers Explains how to implement

More information

Broadcom NetXtreme Gigabit Ethernet Adapters IBM Redbooks Product Guide

Broadcom NetXtreme Gigabit Ethernet Adapters IBM Redbooks Product Guide Broadcom NetXtreme Gigabit Ethernet Adapters IBM Redbooks Product Guide The Broadcom NetXtreme Gigabit Ethernet Adapters are a family of high performance PCI Express adapters. With five adapters to choose

More information

Tivoli Storage Manager for Virtual Environments: Data Protection for VMware Solution Design Considerations IBM Redbooks Solution Guide

Tivoli Storage Manager for Virtual Environments: Data Protection for VMware Solution Design Considerations IBM Redbooks Solution Guide Tivoli Storage Manager for Virtual Environments: Data Protection for VMware Solution Design Considerations IBM Redbooks Solution Guide IBM Tivoli Storage Manager for Virtual Environments (referred to as

More information

Platform LSF Version 9 Release 1.1. Migrating on Windows SC

Platform LSF Version 9 Release 1.1. Migrating on Windows SC Platform LSF Version 9 Release 1.1 Migrating on Windows SC27-5317-00 Platform LSF Version 9 Release 1.1 Migrating on Windows SC27-5317-00 Note Before using this information and the product it supports,

More information

SAS Connectivity Card (CIOv) for IBM BladeCenter IBM Redbooks Product Guide

SAS Connectivity Card (CIOv) for IBM BladeCenter IBM Redbooks Product Guide SAS Connectivity Card (CIOv) for IBM BladeCenter IBM Redbooks Product Guide The SAS Connectivity Card (CIOv) for IBM BladeCenter is an expansion card that offers the ideal way to connect the supported

More information

Broadcom NetXtreme 10 GbE SFP+ Network Adapter Family for System x IBM Redbooks Product Guide

Broadcom NetXtreme 10 GbE SFP+ Network Adapter Family for System x IBM Redbooks Product Guide Broadcom NetXtreme 10 GbE SFP+ Network Adapter Family for System x IBM Redbooks Product Guide IBM offers a Broadcom 10 GbE SFP+ network adapter family that is based on the Broadcom BCM57811S and BCM57810S

More information

ServeRAID-BR10il SAS/SATA Controller v2 for IBM System x IBM System x at-a-glance guide

ServeRAID-BR10il SAS/SATA Controller v2 for IBM System x IBM System x at-a-glance guide ServeRAID-BR10il SAS/SATA Controller v2 for IBM System x IBM System x at-a-glance guide The ServeRAID-BR10il SAS/SATA Controller v2 is an ideal solution for servers that need high-speed data transfer in

More information

Networking Terminology Cheat Sheet

Networking Terminology Cheat Sheet Networking Cheat Sheet YOUR REFERENCE SHEET FOR GOING WEB-SCALE WITH CUMULUS LINUX With Cumulus Linux, you can build a web-scale data center with all the scalability, efficiency and automation available

More information