Small Intelligent CAN Card for USB

Size: px
Start display at page:

Download "Small Intelligent CAN Card for USB"

Transcription

1 User Manual USBAN-I-mini UM V1.00 Date: 2015/10/8 User Manual Item Keywords Abstract ontent USBAN-I-mini, high performance, portable The USBAN-I-mini device complies with AN2.0A/B specification, supports any baudrate in the range of 5Kbps~1Mbps and provides device drives for multiple operating systems. It provides reliable and high-efficiency solution for industrial communication AN network, meeting various application requirements. Guangzhou ZHIYUAN Electronics o., Ltd.

2 Revision History USBAN-I-mini User Manual Version Rev. Date Modifications V /10/08 reated the document. i

3 ontents USBAN-I-mini User Manual hapter 1: Introduction Overview Specifications Product Appearance Typical Applications... 5 hapter 2: Device Installation AN-bus onnector Signal Indicator System onnection AN-bus onnection Bus Terminal Resistance... 8 hapter 3: Driver Installation Install the driver in Windows system for the first time heck whether the device is installed successfully Open the Device Manager in the Windows system onfirm whether the new device is installed successfully Install the driver in Linux hapter 4: Quick Start Guide Basic Operations of ANTest Software Device Type Selection Filter Settings Start AN Obtain device information Transmitting and receiving demonstration Build a test environment Open device Data Transmission Save in real time and stop saving Bus Utilization Rate Error Information Display hapter 5: Interface Function Usage How to call dynamic library in Windows How to call dynamic library in V development environment How to call dynamic library in VB development environment Interface Library Function Use Flow hart hapter 6: Inspection and Maintenance ii

4 USBAN-I-mini User Manual hapter 7: Rights & Statements Appendix A: AN Message Filter Settings A.1 Single Filter onfiguration A.2 Dual Filter onfiguration Appendix B: DB9 to OBD Interface B.1 Function Introduction B.2 Technical Specifications B.3 Pin Information B.3.1 Pin Assignments of DB9 onnector B.3.2 Pin Description of DB9 connector B.3.3 Pin assignments of OBD connector B.3.4 Pin Description of OBD onnector B.4 Mechanical Dimensions Appendix : Standard SJA1000 Baudrate iii

5 hapter 1: Introduction USBAN-I-mini User Manual 1.1 Overview The USBAN-I-mini intelligent AN interface card is a portable version of USBAN series and fully compatible with the USBAN-I single-channel intelligent AN interface card. It is an intelligent AN-bus communication interface card with 1- channel AN interface, and compatible with USB1.1 bus. Using the USBAN-I-mini intelligent AN interface card, a P can be connected with the AN-bus network through USB bus, which form the AN-bus network control node to process and acquire data in AN-bus network fields, such as field bus laboratory, industrial control, intelligent house, automotive electronic network. The USBAN-I-mini intelligent AN interface card is a powerful for AN-bus product development and AN-bus data analysis. Furthermore, due to its small size and plug-and-play, the USBAN-I-mini intelligent AN interface card is the best choice for portable system users. The AN card is equipped with an electrical isolation module, which prevents damage from ground circulation and improves its usage reliability in severe environments. The AN card supports Win9x/Me, Win2000/XP, Linux2.4, Linux2.6 and other operating systems. It also provides unified application programming interface and complete application demonstration code (including V, VB, Delphi, ++Builder and other demonstration code examples) for users to develop their application programs. The USBAN-I-mini interface card also supports OP interface. That means the card can be used in the configuration software that supports OP. In addition, the ANTest general testing software is provided for AN-bus message transmitting, receiving and monitoring. 1.2 Specifications P interface is compliance with USB2.0 protocol specification, and compatible with USB3.0 and USB1.1. It supports AN2.0A and AN2.0B protocols and conforms to ISO/DIS /2/3 standards. It is integrated with 1-channel AN-bus interface. Programmable AN-bus communication baudrate in the range of 5Kbps~1 Mbps. The power supply can be provided via the USB Bus. The AN channel is provided with electromagnetic isolation and D/D power isolation; and the isolation voltage is 3000VD. Maximum frame traffic of single channel: frames/ second for receiving, 4

6 USBAN-I-mini User Manual 3000 frames/ second for transmitting. It supports Win9x/Me, Win2000, WinXP and other Windows operating systems. EM level of AN interface:±4kv contact discharge, ±1KV group pulse. 1.3 Product Appearance Figure 1-1: USBAN-I-mini intelligent AN interface card (1) Figure 1-2: USBAN-I-mini intelligent AN interface card (2) 1.4 Typical Applications AN-bus diagnosis and test Automotive electronic application Electric power communication network Industrial control device High-speed, large data communication 5

7 USBAN-I-mini User Manual hapter 2: Device Installation 2.1 AN-bus onnector The USBAN-I-mini interface card is integrated with one AN-bus channel, which connects with the actual AN-bus network through DB9 pin-type socket or DB9 hole-type socket. Table 2-1 shows the pin definition of DB9 socket. The pin definition complies with the DeviceNet and ANopen standard. Table 2-1: AN-bus signal connection (DB9 socket) DB9 Pin-type Socket Pin Signal Description 1 N. Not used 2 AN_L AN_L signal line 3 AN_GND Reference ground 4 N.. Not used 5 AN_SHIELD Shielded line 6 AN_GND Reference ground 7 AN_H AN_H signal line 8 N.. Not used 9 N.. Not used The AN-bus signal of DB9 socket can be converted to the 5-pin OPEN5 connector through the optional DB9OPEN5 converter. The OPEN5 connector is easier to connect and its interface description is shown in Table 2-2. Table 2-2: Pin assignment of DB9OPEN5 converter (OPEN5 socket) OPEN5 Socket Pin Signal Description 1 V- Negative network power supply 2 AN_L AN_L signal line 3 SHIELD Shielded line (FG) 4 AN_H AN_H signal line 5 V+ Positive network power supply 2.2 Signal Indicator The USBAN-I-mini interface card contains one dual-color SYS indicator and one RUN indicator to indicate the operating status of device. The function of two indicators is described in Table 2-3 and Table

8 USBAN-I-mini User Manual Table 2-3: Indicators on the USBAN-I-mini interface card Indicators Status Function Red Indicates the device initialization status. SYS Green Indicates USB interface signal. RUN Green Indicates AN interface operating status. When the USBAN-I-mini interface card is powered on, the SYS indicator is red to indicate that the device is powered on and the system is being initialized. If the SYS indicator is off, it indicates that there is system power supply fault or serious system error. After the USB interface is connected properly, the SYS indicator changes to green color from red color. When there is data transmission through the USB interface, the SYS indicator becomes green and flashes. When the RUN indicator lights, it indicates the AN controller has finished initialization and enters into normal operating status. Table 2-4: Indicator status of USBAN-I-mini interface card AN Indicator Status RUN indicator is off. RUN indicator is on. AN-bus Status The connection between AN controller and AN-bus is off. The AN bus is operating properly. 2.3 System onnection AN-bus onnection When the USBAN-I-mini interface card is connected to AN-bus Bus, users only need to connect AN_L with AN_L signal, AN_H with AN_H signal. The AN-bus network uses linear topology, and the two terminals of bus should be connected with a 120Ω terminal resistance; if the number of nodes is greater than 2, the intermediate node does not need to connect with a 120Ω terminal resistance. For branch connections, the connection distance should not exceed 3m. The AN-bus connection is shown in Figure 2-1. Terminal Resistance Terminal Resistance Figure 2-1: AN-bus network topology Notes: The AN-bus can use common twisted pair or shielded twisted pair. If the 7

9 USBAN-I-mini User Manual communication distance exceeds 1Km, the section area of cable should be greater than 1.0mm 2, which depends on the specific distance. Generally, longer the communication distance is, greater the section area of cable is Bus Terminal Resistance In general, the two terminals of AN-bus network should be added a terminal matching resistance to improve communication reliability, as shown in Figure 2-1. The value of terminal matching resistance is determined by the characteristic impedance of transmission cable. For example, if the characteristic impedance of twisted pair is 120Ω, two terminals of AN-bus should be connected with a 120Ω terminal resistance. In addition, the USBAN-I-mini interface card uses FreeScale M33901WEF high-performance AN transceiver; therefore, if the other nodes on the network use different transceivers, the terminal resistance must be calculated separately. The USBAN-I-mini intelligent AN interface card is integrated with an internal 120Ω terminal resistance, without the need of external terminal resistance. The USB port on the USBAN-I-mini interface card is compliance with USB1.1 specification, and can be connected to a P with USB1.1 or USB2.0 interface. 8

10 USBAN-I-mini User Manual hapter 3: Driver Installation 3.1 Install the driver in Windows system for the first time A. Find usbcan.inf file in the \USBAN\Driver directory and copy it to the windows\inf directory, and find usbcan.sys file and copy it to the \windows\system32\driver. B. After the files are copied successfully, connects the USBAN-I-mini intelligent AN interface card with a P through the USB cable; Then the window system will detect a new hardware device and automatically start the Find new hardware device wizard, you can click Next to continue.. Start to search the new hardware device in the wizard. 9

11 USBAN-I-mini User Manual D. After a while, the warning about incompatibility between the driver and the operating system may be issued in the Windows XP/Windows 2000, please ignore it and click the ontinue button directly. E. ontinue to install the driver. The installation is completed after find the new hardware device. F. lick the Finish button. The SYS indicator on the USBAN-I-mini interface card turns green from red, which indicates the hardware driver is installed successfully and can be used. 3.2 heck whether the device is installed successfully Open the Device Manager in the Windows system A. Right click the My omputer icon on the desktop. B. Select the Properties option on the dropdown menu.. Select the Hardware tag. 10

12 USBAN-I-mini User Manual D. lick the Device Manger button to open the current hardware device list onfirm whether the new device is installed successfully heck the Universal serial bus device device class to view whether the USBAN device is already in the current hardware list. If the device driver is installed successfully, the USBAN device will be seen under the Universal serial bus device device class in the Device Manager interface. The following figure shows the interface after the ZLG USBAN series intelligent AN interface card device is installed properly. When the data transmission is performed between the USBAN-I-mini intelligent AN interface card and a P, the SYS indicator on the interface card becomes green and flashes. 3.3 Install the driver in Linux A. opy usbcan.ko and libusbcan.so.1 to the /lib directory to creat symblic link. # ln s/lib/libusbcan.so.1/lib/libusbscan.so Notes: Please obtain the usbcan.ko or libusbcan.so.1 from our R&D engineer. B. Load the driver: # insmod/lib/usbcan.ko. heck whether the driver is loaded successfully. One line of module information will be list when load the driver successfully; otherwise it indicates that the driver load fails. # lsmod grep usbcan D. Switch to the directory./test. E. ompile the make test routine. Please note this step is optional, and there is compiled routines in the./test directory. F. Run the test routine in the./test directory. G. The test routine perform tests for each channel in the way of self-transmitting and 11

13 USBAN-I-mini User Manual self-receiving. If the board works properly, the number of frames and the transmission speed will be displayed after the operation is completed. Notes: The old release is not open source, therefore users should apply to the R&D department of ZHIYUAN Electronics for customized driver when the kernel needs to be changed. 12

14 USBAN-I-mini User Manual hapter 4: Quick Start Guide 4.1 Basic Operations of ANTest Software Users can obtain the ANTest_Setup_Vx.xx.exe installation file of ANtest testing software in the product D. Figure 4-1 shows the software icon after the ANTest software is installed successfully. Figure 4-1: ANTest software icon Notes: The ANTest software can be downloaded via /product_detail.php?id= Device Type Selection Select USBAN1 from the Select Device menu before operation, as shown in Figure 4-2. Figure 4-2: Device type selection The Open Device dialog box pops up after selection, as shown in Figure

15 USBAN-I-mini User Manual Figure 4-3: Open Device dialog box In this dialog box, users can select the Device Index Number and hannel No. for the device and set the AN initialization parameters, then click OK button to open the device operation window (or click onfirm and start AN button to open the device operation window and automatically open device and start AN channel). Notes: The Device Index Number is the code to identify a device. The same device with different AN interfaces should select same device index number and the different devices should select different device index number. The initial value of device index number is 0. Notes: The hannel Number is used to distinguish different AN channels of the same device, and its initial value is 0. Since the USBAN-I-mini device only have single AN channel, the hannel Number is Filter Settings Then, click Filter Settings button to set filter in the device operation window (if it is not necessary to set filter, please ignore this step), as shown in Figure

16 USBAN-I-mini User Manual Figure 4-4: Filter settings 1 The Filter Settings dialog box will pops up, as shown in Figure 4-5. Figure 4-5: Filter Settings 2 Select the filter mode, and then set filter for those AN frames that need to be filtered Start AN lick Start button to start a AN channel, and the received AN data will be automatically displayed in the data list, as shown in Figure

17 USBAN-I-mini User Manual Figure 4-6: Start Obtain device information Figure 4-7: Device operations After start the AN channel, users can select the Device information option in the Device Operations menu to obtain the detailed information of current device, as shown in Figure

18 USBAN-I-mini User Manual 4.2 Transmitting and receiving demonstration This section describes simple transmitting and receiving test and bus utilization rate demonstration Build a test environment onnect the USBAN-I-mini interface card with a P and the device to be tested and make sure the correct connection. For interface definition, please refer to Appendix B Open device Run the ANTest software and select device type. onfigure the device and start it, as shown in Figure 4-8. Figure 4-8: Initial device parameters setup Notes: The Device Index Number is the code to identify a device. The same device with different AN interfaces should select same device index number and the different devices should select different device index number. The initial value of device index number is 0. Notes: The hannel Number is used to distinguish different AN channels of the same device, and its initial value is 0. Since the USBAN-I-mini device only have single AN channel, the hannel Number is Data Transmission After start AN-bus successfully, set various parameters for the AN frame, and then click the Send button to transmit data (the Self-transmitting and self-receiving option in the dropdown box of Transmission mode means that the transmitted AN frame can be received by the sender. This option is only for test. Please select the 17

19 USBAN-I-mini User Manual Normal transmission in the practical application). Figure 4-9: Basic settings of data transmission Users can click the Advanced Operation tag to enter into the advanced operation page. In this page, users may set the number of different AN frames that are allowed to transmit each time (at most 100 frames), the interval between each frame and the interval between each batch of frames, as shown in Figure Figure 4-10: Advanced settings of data transmission Figure 4-11 and Figure 4-12 show the results of data transmitting and receiving respectively. Figure 4-11: Data transmitting result 18

20 USBAN-I-mini User Manual Figure 4-12: Data receiving result Save in real time and stop saving When it is necessary to record messages in a long time, the Save in real time function should be used. If the software buffer is full, the subsequent messages are saved into the file in the hard disk (in SV format) and the software buffer is cleared. The names of message files can be automatically numbered in turn, which should be enabled before start. Note that the drive should not be specified as storage location; otherwise the message may not be saved. lick Stop saving to stop saving messages into the hard disk, as shown in Figure Figure 4-13: Save message Bus Utilization Rate lick BusFlow to open the Bus Utilization Rate interface. The current bus utilization rate and frame rate can be monitored in real time. The display speed can 19

21 USBAN-I-mini User Manual be adjusted by adjusting refresh time, as shown in Figure Figure 4-14: Bus utilization rate Error Information Display lick Error Information to open the Error Information Display interface. When there is error occurred in the AN channel, it will print the error information (transmitting error counter value and receiving error counter value) and the time when the error takes place, as shown in Figure Figure 4-15: Error information display 20

22 USBAN-I-mini User Manual hapter 5: Interface Function Usage The effective and easy-to-use secondary development function are provided, which support various development environments like V, #, Labview, LINUX, etc, as shown in Figure 5-1. Figure 5-1: Development environment support 5.1 How to call dynamic library in Windows First, save the library function file into the working directory. The library function file contains 3 files (ontrolan.h, ontrolan.lib and ontrolan.dll) and 1 folder (kerneldlls) How to call dynamic library in V development environment (1) Include the ontrolan.h file into the file with.pp extension. For example, #include ontrolan.h (2) Set ontrolan.lib file link in the project linker setting. For example, add ontrolan.lib in the onfiguration Properties Linker Input Additional dependent items of the project property page in the V7 environment How to call dynamic library in VB development environment The dynamic library can be called after making the following declaration. Grammar: 21

23 USBAN-I-mini User Manual [Public Private] Declare Function name Lib "libname" [Alias "aliasname"] [([arglist])] [As type] Declare statement contains the following parts: Public (optional) It is used to declare the functions that can be called in all procedures of all modules. Private (optional) It is used to declare the functions that can only be used in the modules including this declaration. Name (required) Any legal function name. It is the function name at DLL entry point and case-sensitive. Libname (required) It contains the declared function dynamic link library name or code source name. Alias (optional) It indicates the function to be called has another name in DLL. If an external function has the same name with a certain function, this parameter is used. When the function in DLL has the same name with the public variable and constant in the same area or the other procedures, this parameter can be used. If the naming of a certain character of the function in DLL does not comply with the naming convention of DLL, this parameter can also be used. Aliasname (optional) Dynamic link library. If the first character is not a numeric symbol (#), the aliasname is the name of the function at DLL entry point. If the first character is (#), the sequent character should specify the number of the function in the entry point. Arglist (optional) It represents the argument list to be passed when calling this function. Type (optional) It is the data type of the function return value, which can be Byte, Boolean, Integer, Long, urrency, Single, Double, Decimal (not supported currently), Date, String or Variant, user-defined type, or object type. The grammar of arglist parameter is as follows: [Optional] [ByVal ByRef] [ParamArray] varname[( )] [As type] Description: 22

24 Optional (optional) USBAN-I-mini User Manual It indicates that the parameter is not required. If this option is used, the subsequent arguments in arglist must be optional and must be declared using the Optional keyword. If ParamArray is used, any parameter can not use Optional. ByVal (optional) It indicates this parameter is passed by value. ByRef (optional) It indicates this parameter is passed by address. For example: Public Declare Function VI_OpenDevice Lib "ontrolan" (ByValdevicetypeAs Long, ByValdeviceind As Long, ByVal reserved As Long) As Long 23

25 USBAN-I-mini User Manual 5.2 Interface Library Function Use Flow hart 24

26 USBAN-I-mini User Manual hapter 6: Inspection and Maintenance The main electrical components of USBAN-I-mini interface card are semiconductor parts. Although these parts have long life time, they may age quickly if used in improper environment. Therefore, the device should be inspected regularly to guarantee it is used in the allowable condition. The device is recommended to be inspected at least once per 6 months to 1 year, and it should be inspected more frequently if used in the improper environment. If there is problem occurred during the device maintenance, please read the following table to find the cause. If the problem can not be solved yet, please contact ZLG ZHIYUAN Electronics. No. ontent Inspection riterion Operation 1 Power supply Ambient 2 environment heck the voltage fluctuation of power supply input heck ambient temperature (including internal temperature in the closed environment) heck ambient humidity (including internal humidity in the closed environment) heck the accumulation of dust, powder, salt, metal shavings heck whether water, oil, or chemical spray touches the device heck whether there is corrosive or flammable gases around the device heck vibration and shock heck the noise source near the device +5V D USB port power supply Use a voltmeter to measure the USB port voltage on the power supply input terminal. -25 ~+85 Use a thermometer to measure temperature and ensure the ambient temperature remains within the allowable range. The relative humidity Use a hygrometer to measure should be 10%~90% humidity and ensure the without ambient humidity remains air-conditioning. within the allowable range. No accumulation lean and protect the device. No spray touches If necessary, please clean and the device. protect the device. No corrosive or Smell or use a sensor to flammable gas check whether there is corrosive or flammable gas. Vibration and shock If necessary, please install a within the specified gasket or other shock limits absorber. No important noise Isolate the device from noise signal source source or protect the device 25

27 USBAN-I-mini User Manual No. ontent Inspection riterion Operation heck the connection of each unit and whether each unit has No loosening Fully press the connectors together and lock them with the slider been securely locked with next unit. heck whether the cable connector is inserted and locked No loosening orrect any error connection installation. 3 Installation completely. and wiring heck whether there is No loosening Tighten the screw with a loose screw in the screwdriver. external wiring. heck the crimp connector in the There is enough space between heck it visually, and adjust it if necessary external wiring connectors. heck whether there is any damage in the external cable. No damage heck it visually, and replace the cable if necessary 26

28 USBAN-I-mini User Manual hapter 7: Rights & Statements This document provides information about ZHIYUAN electronic products. This document does not grant any intellectual property license and does not grant any intellectual property license by express or implied, or by way of prohibited speech or other means. ZHIYUAN Electronics shall not be liable for any liability other than the liability stated in the terms and conditions of sale of its products. Furthermore, with regard to the sale and / or use of its products, ZHIYUAN Electronics does not makes any express or implied warranty, including any use of the product for specific purposes, merchantability or infringement of any patent, copyright or other intellectual property rights. The products from ZHIYUAN electronic are not designed for medical, life-saving or life-sustaining purposes. ZHIYUAN Electronics reserves the right to revise product specifications and descriptions at any time without notice. 27

29 USBAN-I-mini User Manual Appendix A: AN Message Filter Settings The AN message filter of this converter is designed based on the PeliAN mode of PHILIPS SJA1000 AN controller. The filter of SJA1000 is composed of 4 groups (4 bytes) of acceptance code register (AR) and 4 groups (4 bytes) of acceptance mask register (AMR). The AR value is predefined acceptance code value, and the AMR value indicates whether the corresponding AR value is used for acceptance filtering. However, some registers of the filter are not used in some modes of the SJA1000. For ease of use, only the actual value of the filter is involved in the configuration software and the irrelevant data is discarded. The general rule of filtering is that each acceptance mask bit corresponds to an acceptance code bit. When the acceptance mask bit is 1 (that is, don t care), it indicates acceptance regardless of whether the received frame ID bit is equal to the corresponding acceptance code bit; however, when the acceptance mask bit is 0 (relevant), it indicates acceptance only if the received frame ID bit is equal to the corresponding acceptance code bit. And only when all single bit comparisons signal acceptance, AN controller will receive the frame message. The filter mode is divided into single filter and dual filter. The filter is slightly different between standard frame and extended frame. If the user-defined acceptance mask is set in the configuration software, all filter function is enabled, which is described as follows: A.1 Single Filter onfiguration In this filter configuration, one long filter could be defined. The bit correspondences between the filter bytes and the message bytes depend on the currently received frame format. Standard frame: if a standard frame format is used, only part of data bits (lower 11 bits) of the first two AR bytes (AR3 and AR4) is used for acceptance filtering; similarly, only lower 11 bits of AMR3 and AMR4 are used for acceptance filtering. If a bit in AMR is 0 (relevant), when the corresponding bit (such as, AR1.0 corresponds to AMR1.0 and ID.00) in AR is equal to the received frame identifier bit, it indicates acceptance (logic 1); when the values of two bits are not equal, it indicates not acceptance (logic 0). On the other hand, if a bit in AMR is 1, it indicates acceptance (logic 1) regardless of whether the corresponding bit in AR is equal to the received frame identifier bit. For a successful reception of a message, all single bit comparisons have to signal acceptance, as shown in Figure

30 USBAN-I-mini User Manual Acceptance code Acceptance mask Received frame identifier Message bit Acceptance code bit Acceptance mask bit bit x of data byte Acceptance ode Register Acceptance Mask Register Accepted Not accepted Figure 8-1: Single filter configuration, receiving standard frame messages Extended frame: when an extended frame format is used, since the frame identifier is 29 bits, part of data bits (lower 29 bits) of four AR bytes is used for acceptance filtering; similarly, only lower 29 bits of AMR are used for acceptance filtering. For a successful reception of a message, all single bit comparisons have to signal acceptance, as shown in Figure 8-2. Acceptance code Acceptance mask Frame identifier Filter 1 Acceptance mask bit Acceptance code bit Acceptance ode Register Acceptance Mask Register Frame identifier bit Accepted Not accepted Filter 2 Acceptance code bit Acceptance mask bit bit x of data byte Figure 8-2: Single filter configuration, receiving extended frame messages. 29

31 A.2 Dual Filter onfiguration USBAN-I-mini User Manual In this filter configuration, two short filters can be defined. A received message is compared with both filters to decide whether this message should be copied into the receive buffer or not. If at least one of the filters signals an acceptance, the received message becomes valid. The bit correspondences between the filter bytes and the message bytes depend on the currently received frame format. Standard frame: for a standard frame, it means the acceptance filtering is performed for the received frame identifier in the case of two single filters. The acceptance logic is shown in Figure 8-3. For a successful reception of a message, all single bit comparisons of at least one complete filter have to signal acceptance. The message frame can be received only when at least one filter signals acceptance. Filter 1 Received frame identifier Filter 2 Filter 1 Acceptance mask bit Acceptance code bit Acceptance ode Register Acceptance Mask Register Frame identifier bit Accepted Not accepted Filter 2 Acceptance code bit Acceptance mask bit bit x of data byte Figure 8-3: Dual filter configuration, receiving standard frame messages. Extended frame: for an extended frame, the two defined filters are identical. Both two filters only compare the first two bytes of extended identifier (i.e., ID.28~ID.13), not the whole 29 bit identifier, as shown in Figure

32 USBAN-I-mini User Manual For a successful reception of a message, all single bit comparisons of at least one complete filter have to signal acceptance. The message frame can be received only when at least one filter signals acceptance. Filter 1 Received frame identifier Filter 2 Filter 1 Acceptance mask bit Acceptance code bit Acceptance ode Register Acceptance Mask Register Frame identifier bit Filter 2 Acceptance code bit Acceptance mask bit Accepted Not accepted bit x of data byte Figure 8-4: Dual filter configuration, receiving extended frame messages. 31

33 USBAN-I-mini User Manual Appendix B: DB9 to OBD Interface B.1 Function Introduction The DB9-OBD is an accessory of the USBAN-I-mini device. One terminal is connected to the Port header of USBAN-I-mini (DB9 interface), and another terminal directly plugs into the OBD interface of automobile, so that users can use the USBAN-I-mini to diagnose and test an automobile. Figure 9-1: Appearance of DB9-OBD B.2 Technical Specifications Input voltage range: 60V. Input current range: Isolation resistance between lines: >=100MΩ. Temperature range: -20~+80. Times of plugging and unplugging: >=100. B.3 Pin Information B.3.1 Pin Assignments of DB9 onnector 32

34 USBAN-I-mini User Manual Figure 9-2: Pin assignments of DB9 connector B.3.2 Pin Description of DB9 connector Pin No. Pin Name Description 1 N. Not used. 2 AN_L AN_L signal line 3 AN_GND Reference ground 4 N.. Not used 5 AN_SHIELD Shielded line 6 AN_GND Reference ground 7 AN_H AN_H signal line 8 N.. Not used 9 N.. Not used Figure 9-3: Pin description of DB9 connector B.3.3 Pin assignments of OBD connector Figure 9-4: Pin assignments of OBD connector B.3.4 Pin Description of OBD onnector Pin No. Pin Name Description 5 GND onnect to Pin 6 of DB9 directly 12 ANH ANL -- Notes: Other pins are not used and left floating. Figure 9-5: Pin description of OBD connector 33

35 B.4 Mechanical Dimensions USBAN-I-mini User Manual Figure 9-6: Mechanical dimensions of DB9 connector Figure 9-7: Mechanical dimensions of OBD connector 34

36 USBAN-I-mini User Manual Appendix : Standard SJA1000 Baudrate No. Baudrate rystal Oscillator Frequency = 16MHz (Kbps) BTR0 (Hex) BTR1 (Hex) 1 5 BF FF 2 10* * FF 5 50* FF 7 100* * FA * FA * B * * Notes: The value with * in the table is the baudrate recommended by IA association. 35

37 Sales Information USBAN-I-mini User Manual Guangzhou ZHIYUAN Electronics o., Ltd Address:Floor 2, Building No.7, Huangzhou Industrial Estate, hebei Road, Tianhe District, Guangzhou. Zip ode: Website: Nationwide service hotline: Nationwide service hotline: Sales and service network: Guangzhou Sales Office Floor 2, Building No.7, Huangzhou Industrial Estate, hebei Road, Tianhe District, Guangzhou. TEL:(020) Shanghai Branch: Shanghai Room 12E, Jingcheng Building (E), No.668 Beijing Road (E), Shanghai. TEL:(021) Beijing Branch F/19, Haojing Building A, No.108 Zhichun Road, Haidian District, Beijing. TEL:(010) Shanghai Branch: Nanjing Room 1501, Pearl River Building, No.280 Pearl River Road, Nanjing. TEL:(025) Shenzhen Office Room 1203, F/12 Electronics Building, No.2072 Shennan Road (M), Futian District, Shenzhen. TEL:(0755) Shanghai Branch: Hangzhou Room 502, Jiangnan Electronics Building, No.217 Tianmushan Road, Hangzhou. TEL:(0571) Wuhan Office Room 12128, No.158 Luoyu Road, Guangbu Village, Hongshan District, Wuhan. TEL:(027) hongqing Office Room 2705, Atlantic International Building (SEG Electronics Market), Shiqiaopu Science and Technology Park Road I, hongqing. TEL:(023) hengdu Office Room 403, Digital Technology Building, No.1 Yihuan Road, South 2nd section, hengdu. TEL:(028) Xi an Office Room 1201, Pacific Building, No.54 hangan Road (N), Xi an. TEL:(029) Please contact us with the above information. Thank you for your attention to our products! 36

CANWiFi-200T User Manual

CANWiFi-200T User Manual User Manual High Performance 2-channel WiFi-to-AN onverter V1.02 User Manual Item Keywords Abstract ontent AN-bus, WiFi, Ethernet, 2-channel, High performance ANWiFi-200T is a high-performance 2-channel

More information

CANET-E(2E)-U User Manual

CANET-E(2E)-U User Manual User Manual High Performance Single/dual-channel Ethernet-to-CAN Converter UM01010101 V1.04 User Manual Item Keywords Abstract Content CAN-bus Ethernet Single/dual-channel High performance CANET-E(2E)-U

More information

USBCAN Interface. Typical Applications. Operation system supported: CAN controller: SJA1000T. Windows98/Me/2000/XP/2003 CAN transceiver: PCA82C251

USBCAN Interface. Typical Applications. Operation system supported: CAN controller: SJA1000T. Windows98/Me/2000/XP/2003 CAN transceiver: PCA82C251 DataSheet USBCAN Interface Intelligent CAN-bus Interface UM010206 Rev 2.00 Date:3/5/2007 Overview is an intelligent PC-CAN interface module which is compatible with USB1.1 and supports one or two CAN channels.

More information

CANScope. CANScope Analyzer

CANScope. CANScope Analyzer User Manual Analyzer UM12090301 V1.01 User Manual Item Terms Abstract ontents, safety on usage, hardware description, P software, parameters This document is an overview on how to use the analyzer. www.zlg.cn

More information

USBCAN-modul 8. Industrial USB to CAN converter. User Manual. Document version 5.0(2017/06/16)

USBCAN-modul 8. Industrial USB to CAN converter. User Manual. Document version 5.0(2017/06/16) USBCAN-modul 8 Industrial USB to CAN converter User Manual Document version 5.0(2017/06/16) Contents 1. Introduction... 4 1.1 Overview... 4 1.2 Properties at a glance...4 1.3 Typical application... 4 2.

More information

USBCAN-OBD. USB to CAN adapter. User Manual. Document version 3.01 (2015/04/22)

USBCAN-OBD. USB to CAN adapter. User Manual. Document version 3.01 (2015/04/22) USB to CAN adapter User Manual Document version 3.01 (2015/04/22) Contents 1. Introduction... 3 1.1 Functional Overview... 3 1.2 Properties at a Glance...3 1.3 Typical application... 3 2. Installation...

More information

USBCAN-I Pro. USB to CAN adapter. User Manual. Ver.:V3.01 (2015/04/22)

USBCAN-I Pro. USB to CAN adapter. User Manual. Ver.:V3.01 (2015/04/22) USB to CAN adapter Ver.:V3.01 (2015/04/22) Revision History: Ver. Date Reason V1.00 2013/6/16 Create document V2.01 2013/12/20 Fixed working parameters V3.01 2015/04/22 Add some parameters 2 Contents Contents...

More information

CANCore-I/II. User Manual. Industrial grade CAN module. Ver.:V3.02 (2016/10/22)

CANCore-I/II. User Manual. Industrial grade CAN module. Ver.:V3.02 (2016/10/22) CANCore-I/II Industrial grade CAN module User Manual Ver.:V3.02 (2016/10/22) Contents 1. Introduction... 3 1.1 Functional Overview... 3 1.2 Properties at a Glance...3 1.3 Typical application... 4 2. Installation...

More information

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions 3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These

More information

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION H Series PLC EH-150 Analog input module EH-AXH8M Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction manual and all the

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

Analog Input/Output Modules

Analog Input/Output Modules User s Manual Analog Input/Output Modules Addendum Manual No. :IM 34M06H11-01E Manual Title :Analog Input/Output Modules Edition :1st Edition With the adoption of the CE Marking conformance declaration

More information

MTP58-FTxx-T1. Evaluation Board for the Micro-Thermal Printer

MTP58-FTxx-T1. Evaluation Board for the Micro-Thermal Printer User Manual Evaluation Board for the Micro-Thermal Printer UM01010101 V1.00 User Manual Item Terms Abstract Contents, Evaluation Board, Micro-Thermal, Label Printing, 58mm Guangzhou ZLGMCU Technology Co.,

More information

Installation and Configuration Quick Guide R3000. Industrial Dual SIM Cellular VPN Router 2 Eth + 1 RS RS USB Host.

Installation and Configuration Quick Guide R3000. Industrial Dual SIM Cellular VPN Router 2 Eth + 1 RS RS USB Host. Package Contents Installation and Configuration Quick Guide Before installing your R3000 Router, verify the kit contents as following. 1 x Robustel R3000 Industrial Dual SIM Cellular VPN Router (GPS/WiFi

More information

TF-3239DL 10/100Mbps PCI Network Adapter

TF-3239DL 10/100Mbps PCI Network Adapter Rev: 1.1.0 1910010553 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks

More information

BNI USB A501. User s Guide

BNI USB A501. User s Guide BNI USB-901-013-A501 User s Guide Content 1 Notes for the user 2 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 Enumerations 2 Actions 2 Syntax 2 Cross-references 2

More information

USB to CAN Equipment Specification (V1.01) Contents Aug. 28, Sept. 14, 2012

USB to CAN Equipment Specification (V1.01) Contents Aug. 28, Sept. 14, 2012 USB to Equipment Specification (V1.01) Contents Version Prepared by Date Modification contents V1.0 Li Xinghua V1.01 Li Xinghua 2012-08-28 Aug. 28, 2012 2012-09-14 Sept. 14, 2012 Initial version USB to

More information

High Speed Remote I/O Module

High Speed Remote I/O Module High Speed Remote I/O Module EXF-RC15 The Unitronics EXF-RC15 is a High Speed Remote I/O Module that offers three High Speed Counter inputs and four high speed outputs. Overall, the EXF-RC15 offers 9 digital

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

F1000 User's Manual. (Version: V1.01)

F1000 User's Manual. (Version: V1.01) (Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...

More information

STD_HLS36USB_V1.0E. HLS(MKY36)USB Unit. HLS-36USB Product Manual

STD_HLS36USB_V1.0E. HLS(MKY36)USB Unit. HLS-36USB Product Manual STD_HLS36USB_V1.0E HLS(MKY36)USB Unit HLS-36USB Product Manual Introduction Thank you for purchasing the StepTechnica product. Please check the bundled items. This product consists of the following contents.

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

SER-4485-SI-M USER S MANUAL

SER-4485-SI-M USER S MANUAL SER-4485-SI-M USER S MANUAL 2017 May Edition Titan Electronics Inc. Web: www.titan.tw The computer programs provided with the hardware are supplied under a license. The software provided should be used

More information

Model VC-SHIELD Shield Box

Model VC-SHIELD Shield Box User s Manual Model 733062 VC-SHIELD Shield Box Yokogawa Electric Corporation IM 733062-01E 2nd Edition Introduction Thank you for purchasing the 733062 VC-SHIELD Shield Box. This user s manual contains

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V130 COM Modules: V100-17-CAN, V100-17-RS4/X, V100-17-ET2 This guide shows you how to install an additional communication module in a V130 controller. Instructions and technical specifications

More information

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated

More information

MTP58-Lx6B Series. Guangzhou ZLGMCU Technology Co., Ltd. Product Date Sheet. Document Information

MTP58-Lx6B Series.   Guangzhou ZLGMCU Technology Co., Ltd. Product Date Sheet. Document Information 58mm Micro-thermal Printer Control Board Data Sheet Rev 1.00 Date: 2013/01/17 Product Date Sheet Document Information TYPE CONTENT Key words Micro-thermal Printer, Printing Abstract 58mm Micro-thermal

More information

V E5B Snap-in I/O Module

V E5B Snap-in I/O Module V200-18-E5B Snap-in I/O Module The V200-18-E5B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 18 isolated digital

More information

II. Intelligent PC/CAN Interface USER MANUAL ENGLISH

II. Intelligent PC/CAN Interface USER MANUAL ENGLISH CAN@net II Intelligent PC/CAN Interface USER MANUAL ENGLISH HMS Technology Center Ravensburg GmbH Helmut-Vetter-Straße 2 88213 Ravensburg Germany Tel.: +49 751 56146-0 Fax: +49 751 56146-29 Internet: www.hms-networks.de

More information

VM-11 SERIES MODEL VM-11B ACCELERATION INPUT VIBRATION SIGNAL CONDITIONER INSTRUCTION MANUAL. MANUAL No E1.8. Revised in Mar.

VM-11 SERIES MODEL VM-11B ACCELERATION INPUT VIBRATION SIGNAL CONDITIONER INSTRUCTION MANUAL. MANUAL No E1.8. Revised in Mar. MANUAL No. 29351E1.8 Published in Nov.1991 Revised in Mar.2006 VM-11 SERIES MODEL VM-11B ACCELERATION INPUT VIBRATION SIGNAL CONDITIONER INSTRUCTION MANUAL FOREWORD VM-11B For Use in Safety... Thank you

More information

V E1B Snap-in I/O Module

V E1B Snap-in I/O Module V200-18-E1B Snap-in I/O Module The V200-18-E1B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). Vision OPLC Installation Guide Models 230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). General Description Vision OPLCs

More information

CANET-I/II Isolated CAN to Ethernet Converter V1.0

CANET-I/II Isolated CAN to Ethernet Converter V1.0 CANET-I/II Isolated CAN to Ethernet Converter V1.0 Contents Chapter 1 Product Overview...3 1.1 Product Overview... 3 1.2 Parameters...3 1.3 Typical applications...3 1.4 Ordering Information...3 1.5 Product

More information

Installation and Configuration Quick Guide. R3000 Lite. Industrial Dual SIM Cellular VPN Router (1 Eth + 1 RS RS USB Host)

Installation and Configuration Quick Guide. R3000 Lite. Industrial Dual SIM Cellular VPN Router (1 Eth + 1 RS RS USB Host) Package Contents Before installing your R3000 Lite Router, please verify the kit contents as following. 1 x Robustel R3000 Lite Industrial Dual SIM Cellular VPN Router 1 x 3-pin pluggable terminal block

More information

Appendix 3 Using NS-AL002 Converters

Appendix 3 Using NS-AL002 Converters Appendix 3 Using Converters The RS-232C/RS-422A Converter is connected directly to RS-232C port A or B of the, and converts RS-232C communications to RS-422A/RS-485. Any of the Converters listed in Appendix

More information

User Manual. For 3rd Generation. 5 Axis Standard & Professional Breakout Board Set

User Manual. For 3rd Generation. 5 Axis Standard & Professional Breakout Board Set The 3 rd Generation 5 Axis Breakout Board Set User Manual For 3rd Generation 5 Axis Standard & Professional Breakout Board Set Attention: Please read the manual carefully before using the products! Email:

More information

Conductive Level Controller

Conductive Level Controller Conductive Level Controller 61F-D21T-V1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at ON or OFF using self-holding circuits. Sensitivity adjustment

More information

Dahua HD IR Vari-Focal Fixed Network Camera. Quick Start Guide

Dahua HD IR Vari-Focal Fixed Network Camera. Quick Start Guide Dahua HD IR Vari-Focal Fixed Network Camera Quick Start Guide Version 1.0.0 Dahua Technology CO., LTD Welcome Thank you for purchasing our Network camera! This user s manual is designed to be a reference

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808THS Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

UPort 2000 Series User s Manual

UPort 2000 Series User s Manual User s Manual Second Edition, December 2012 www.moxa.com/product 2012 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be

More information

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd.

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd. WARNING Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd. CONTENTS 1. The company..2 2. Specifications.. 3 3. Package Contents..5 4. Installation, Fix and Transport..6

More information

Package Contents. GP Options (Made by Digital)

Package Contents. GP Options (Made by Digital) When connecting the power cord terminals to the GP, be sure the cord has first been unplugged from the power outlet to prevent the possibility of an electric shock. With the exception of changing the GP's

More information

CANcheck. Installation Tester for CAN/CANopen Networks MANUAL ENGLISH

CANcheck. Installation Tester for CAN/CANopen Networks MANUAL ENGLISH CANcheck Installation Tester for CAN/CANopen Networks MANUAL ENGLISH HMS Technology Center Ravensburg GmbH Helmut-Vetter-Straße 2 88213 Ravensburg Germany Tel.: +49 751 56146-0 Fax: +49 751 56146-29 Internet:

More information

TRANSDUCER T4311, T4411

TRANSDUCER T4311, T4411 TRANSDUCER T4311, T4411 Programmable temperature transducer for RTD Pt1000 sensor with serial output RS232 and RS485 Instruction manual Instruction Manual for use of transducer: T4311 (RS232), T4411 (RS485)

More information

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

User s Manual Model PBL100 Logic Probe IM E. 4th Edition User s Manual Model 701988 PBL100 Logic Probe 4th Edition Foreword Thank you for purchasing the PBL100 100 MHz Logic Probe (Model 701988). This user s manual describes the functions, operating procedures,

More information

USER S MANUAL. FX2N-64DNET DeviceNet Interface Block

USER S MANUAL. FX2N-64DNET DeviceNet Interface Block USER S MANUAL FX2N-64DNET DeviceNet Interface Block FX2N-64DNET DeviceNet Interface Block Foreword This manual contains text, diagrams and explanations which will guide the reader in the correct installation

More information

USB to RS-485/RS-422 Interface Converter. User Manual

USB to RS-485/RS-422 Interface Converter. User Manual USB to RS-485/RS-422 Interface Converter User Manual CONTENTS I. Summary 3 II. Functions..3 III. Hardware installment and application... 3 IV. Performance parameters........4 V. Connector and signal.......4

More information

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01 ABB Drives User s Manual Analogue I/O Extension Module RAIO-01 Analogue I/O Extension Module RAIO-01 User s Manual 3AFE 64484567 REV A EN EFFECTIVE: 1.2.2002 2002 ABB Oy. All Rights Reserved. Safety

More information

HumidiProbe User Guide

HumidiProbe User Guide HumidiProbe User Guide 2005 Pico Technology Limited. All rights reserved. HumidiProbe044-1.3 I HumidiProbe User Manual Contents 1 Introduction...2...2 1 About HumidiProbe...2 2 Intended use...2 3 This

More information

PTC-101-M12 Hardware Installation Guide

PTC-101-M12 Hardware Installation Guide PTC-101-M12 Hardware Installation Guide Moxa Industrial Media Converter Third Edition, May 2014 2014 Moxa Inc. All rights reserved. P/N: 1802001016021 Overview The PTC-101-M12 industrial media converter

More information

Installation and Configuration Quick Guide R2000. Industrial Dual SIM Cellular VPN Router (2 Eth + 2 SIM) Package Contents

Installation and Configuration Quick Guide R2000. Industrial Dual SIM Cellular VPN Router (2 Eth + 2 SIM) Package Contents Package Contents Before installing your R2000 Router, please verify the kit contents as following. 1 x Robustel R2000 Industrial Dual SIM Cellular VPN Router 1 x 3-pin 3.5 mm male terminal block for power

More information

JANOME DESKTOP ROBOT JR2000N Series. Operation Manual. <Setup> For Qualified Installer ONLY

JANOME DESKTOP ROBOT JR2000N Series. Operation Manual. <Setup> For Qualified Installer ONLY JANOME DESKTOP ROBOT JR2000N Series Operation Manual For Qualified Installer ONLY Thank you for purchasing the Janome Robot. *Read this manual thoroughly in order to properly use this robot. Be sure

More information

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide. Safety Instructions Before use Thank you very much for purchasing this product. This product is an interface box called "Connection & Control Box" for EPSON short throw projectors. For your safety, read

More information

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0. ECAN-240 (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.0 Page: 1 Table of Contents Table of Contents -----------------------------------------------------------------------------2

More information

User Manual PCM Port CAN-Bus Mini PCIe Module with Isolation Protection

User Manual PCM Port CAN-Bus Mini PCIe Module with Isolation Protection User Manual PCM-2680 2-Port CAN-Bus Mini PCIe Module with Isolation Protection Copyright The documentation and the software included with this product are copyrighted 2013 by Advantech Co., Ltd. All rights

More information

NI USRP-2900/2901. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Universal Software Radio Peripheral

NI USRP-2900/2901. Contents. Electromagnetic Compatibility Guidelines GETTING STARTED GUIDE. Universal Software Radio Peripheral GETTING STARTED GUIDE NI USRP-2900/2901 Universal Software Radio Peripheral This document explains how to install, configure, and test your NI universal software radio peripheral (USRP) 2900 or 2901 (NI

More information

USB2CAN User Guide. High quality isolated USB to CAN interface. 1.0v

USB2CAN User Guide. High quality isolated USB to CAN interface. 1.0v USB2CAN User Guide High quality isolated USB to CAN interface 1.0v 2016-12-23 Table of Contents 1 Introduction 4 1.1 Usage warning 4 1.2 Technical specification 4 2 USB2CAN converter 5 2.1 Serial number

More information

User Manual MIOe port CAN-bus PCIE/MIOe Module with Isolation Protection

User Manual MIOe port CAN-bus PCIE/MIOe Module with Isolation Protection User Manual MIOe-3680 2-port CAN-bus PCIE/MIOe Module with Isolation Protection Copyright The documentation and the software included with this product are copyrighted 2014 by Advantech Co., Ltd. All rights

More information

Model Number Structure

Model Number Structure Digital Panel Meter CSM DS_E_2_1 Easy-to-use, w-cost Digital Panel Meter that Accepts AC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. ghly visible display

More information

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010 Installation instructions RF-identification system with integrated AS-i slave UK DTSLF 704153 / 07 04 / 2010 Inhalt 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 2.1 General...4

More information

PISO-CAN400-D/T PISO-CAN200-D/T

PISO-CAN400-D/T PISO-CAN200-D/T PISO-CAN400-D/T PISO-CAN200-D/T User s Manual Warranty All products manufactured by ICP DAS are warranted against defective materials for a period of one year from the date of delivery to the original

More information

V E2B Snap-in I/O Module

V E2B Snap-in I/O Module V200-18-E2B Snap-in I/O Module The V200-18-E2B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for

More information

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD. USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD. Table of Contents Precautions... 1 Revision History... 2 Introduction... 2 1. Overview... 3 2. Power Supply... 3 3. Specifications...

More information

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E PROGRAMMABLE CONTROLLER Technical Manual ARCT1F321E-2 2008.11 Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly,

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

V E62B Snap-in I/O Module

V E62B Snap-in I/O Module V200-18-E62B Snap-in I/O Module The V200-18-E62B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 30 isolated digital

More information

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration NX-series SSI Input Unit CSM DS_E_1_1 Read position information from encoders with Synchronous Serial Interface (SSI). Process SSI encoder input data using the MC Function Modules of the NJ-series Machine

More information

Thermal Hybrid PTZ Camera Quick Start Guide

Thermal Hybrid PTZ Camera Quick Start Guide Thermal Hybrid PTZ Camera Quick Start Guide Version 1.0.0 Table of Contents 1 PTZ INSTALLATION... 1 1.1 Installation Preparation... 1 1.1.1 Check installation space and intension... 1 1.1.2 About cable...

More information

Available in 2.0MP, 4.0MP and 8.0MP variants

Available in 2.0MP, 4.0MP and 8.0MP variants Camera Quick Install Guide FBMINIIR Series Available in 2.0MP, 4.0MP and 8.0MP variants Thank you for purchasing a FBMINIIR Series CCTV Surveillance Camera. This Quick Install Guide covers basic setup,

More information

Installation and Configuration Quick Guide GoRugged M1000 MP

Installation and Configuration Quick Guide GoRugged M1000 MP Installation and Configuration Quick Guide GoRugged M1000 MP Industrial Cellular Modem 1 RS-232/RS-485 + 1 USB Host Package Contents Before installing your M1000 MP Modem, verify the kit contents as following.

More information

MEV Limited USB232/485 INSTRUCTION MANUAL

MEV Limited USB232/485 INSTRUCTION MANUAL MEV Limited USB232/485 INSTRUCTION MANUAL USB TO RS232 / RS485 SERIAL COMMUNICATIONS INTERFACE WITH ISOLATION OPTION Issue 5 LIST OF CONTENTS 1 INTRODUCTION 1 1.1 The Products Described in this Manual

More information

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01 ABB Drives User s Manual Modbus Adapter Module RMBA-01 Modbus Adapter Module RMBA-01 User s Manual 3AFE 64498851 REV A EN EFFECTIVE: 1.3.2002 2002 ABB Oy. All Rights Reserved. Safety instructions Overview

More information

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide BNI PNT-104-105-Z015 BNI PNT-202-105-Z015 BNI PNT-302-105-Z015 BNI PNT-305-105-Z015 IP67 Modules User s Guide Content 1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide 3 1.3. Typographical

More information

X-Writer. User Guide for TK Series. Revision 1.8 Dec. 2015

X-Writer. User Guide for TK Series. Revision 1.8 Dec. 2015 for TK Series Revision 1.8 Dec. 2015 ENE RESERVES THE RIGHT TO AMEND THIS DOCUMENT WITHOUT NOTICE AT ANY TIME. ENE ASSUMES NO RESPONSIBILITY FOR ANY ERRORS APPEAR IN THE DOCUMENT, AND ENE DISCLAIMS ANY

More information

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd PRODUCT MANUAL Power Supply Westell Technologies. 960-1152-MNL rd DISCLAIMER All information and statements contained herein are accurate to the best of Westell Technologies knowledge. Westell Technologies

More information

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications IA260 Series Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA Features and Benefits Cirrus Logic EP9315 Arm9 CPU, 200 MHz 128 MB RAM onboard, 32 MB flash disk

More information

Dahua HD Fixed-focal Pinhole Network Camera

Dahua HD Fixed-focal Pinhole Network Camera Dahua HD Fixed-focal Pinhole Network Camera Quick Start Guide Dahua HD Fixed-focal Pinhole Network Camera Quick Start Guide Version 1.0.0 Dahua Technology CO., LTD Dahua HD Fixed-focal Pinhole Network

More information

Electro Magnetic Compatibility (EMC)

Electro Magnetic Compatibility (EMC) Electro Magnetic Compatibility (EMC) This equipment complies with the European rules for EMC according to EN5501, EN5500 and EN5008-1. The equipment conforms to the EMC directive and low-voltage directive.

More information

DVB-S/S2 to IP UDP/MPTS Gateway User Manual

DVB-S/S2 to IP UDP/MPTS Gateway User Manual DVB-S/S2 to IP UDP/MPTS Gateway User Manual Contents 1 SAFETY INSTRUCTION... 2 2 System Composition and Operating Principle... 2 2.1 System Composition... 2 3 Installation Guide... 3 3.1 Installation Preparation...

More information

M M WIFI Module

M M WIFI Module M1000 150M WIFI Module Stable and High Performance 32bit MIPS Processor Compliant with IEEE 802.11n standard, up to 150Mbps Data Rate Small and Castellated Mounting Holes Design 3.3VDC Input Power, Low

More information

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit Fieldbus system PROFIBUS DP Compatible GW unit Operation Manual EX50-GPR URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8 3-507-89 Fax: +8 3-598-536

More information

CAN-Bridge. CAN Communications Module for CAN 2.0 A/B, CAN Layer AA01. Manual. Version 1/ from HW 1 & FW 1.00

CAN-Bridge. CAN Communications Module for CAN 2.0 A/B, CAN Layer AA01. Manual. Version 1/ from HW 1 & FW 1.00 CAN-Bridge CAN Communications Module for CAN 2.0 A/B, CAN Layer 2 700-660-2AA01 Manual Version 1/26.01.2011 from HW 1 & FW 1.00 Manual order number 700-660-2AA01/en Systeme Helmholz GmbH Hannberger Weg

More information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information Chemical-resistant Proximity Sensor E2KQ-X CSM_E2KQ-X_DS_E_4_3 Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster Excellent resistance against chemicals and oil with fluororesincoated case.

More information

BNI PNT Z015. IP67 Modules 16 Input User s Guide

BNI PNT Z015. IP67 Modules 16 Input User s Guide BNI PNT-104-105-Z015 IP67 Modules 16 Input User s Guide Content 1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide 3 1.3. Typographical Conventions 3 Enumerations 3 Actions 3 Syntax 3 Cross-references

More information

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC Interface Converter A compact converter that allows communications between RS-C/USB and RS-/8 devices. Ideal for industrial applications. Allows communications between RS-C/USB (Universal Serial Bus) and

More information

Ordering Information. Interface Converter K3SC. List of Models

Ordering Information. Interface Converter K3SC. List of Models Interface Converter CSM DS_E 1 A compact converter that allows communications between /USB and RS-22/8 devices. Ideal for industrial applications. Allows communications between /USB (Universal Serial Bus)

More information

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO Hardware Manual CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO The expert for industrial and automotive communication IXXAT Headquarter US Sales Office IXXAT Automation GmbH IXXAT Inc. Leibnizstr. 15

More information

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1 Common to all H3CR Note: The undermentioned is common for all H3CR models. Basic Setting Setting of Selectors The s can be turned clockwise and counterclockwise to select the desired time unit, time range,

More information

RS-422/485 to Fiber Industrial Converter

RS-422/485 to Fiber Industrial Converter RS-422/485 to Fiber Industrial Converter (IRF-612) User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or

More information

USB TO RS-232 OR RS-422/485 CONVERTER

USB TO RS-232 OR RS-422/485 CONVERTER DATA SHEET, USB TO RS-232 OR RS-422/485 CONVERTER 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM RS-232 TD RD OVERVIEW USB TO RS-232 OR RS-422/485 OPTO-ISOLATED CONVERTER DATA SHEET INTRODUCTION

More information

BNI EIP Z016. IP67 Modules, 8 Outputs BNI EIP Z016 BNI EIP Z016 IP67 Modules, 16 Outputs User s Guide

BNI EIP Z016. IP67 Modules, 8 Outputs BNI EIP Z016 BNI EIP Z016 IP67 Modules, 16 Outputs User s Guide BNI EIP-202-000-Z016 BNI EIP-202-100-Z016 IP67 Modules, 8 Outputs BNI EIP-206-000-Z016 BNI EIP-206-100-Z016 IP67 Modules, 16 Outputs User s Guide 1 Notes for the user 1.1 About this guide 2 1.2 Structure

More information

PA Series. Available in 6.0MP and 8.0MP

PA Series. Available in 6.0MP and 8.0MP Camera Quick Install Guide PA Series Available in 6.0MP and 8.0MP Thank you for purchasing a PA Series CCTV Surveillance Camera. This Quick Install Guide covers basic setup, installation and use of your

More information

M M WIFI Module

M M WIFI Module M1002 300M WIFI Module Stable and High Performance 32bit MIPS Processor Compliant with IEEE 802.11n standard, up to 300Mbps Data Rate Small and Pin Hole Mounting Design 3.3VDC Input Power, Low Power Consumption

More information

Corporate Introduction

Corporate Introduction ZHIYUAN Electronics Making a world of difference Corporate Introduction Over the past 15 years, Guangzhou ZHIYUAN Electronics Co., Ltd. (hereinafter referred as ZHIYUAN Electronics) has committed itself

More information

Dahua HD Mini IR Waterproof Bullet Network Camera. Quick Start Guide

Dahua HD Mini IR Waterproof Bullet Network Camera. Quick Start Guide Dahua HD Mini IR Waterproof Bullet Network Camera Quick Start Guide Version 1.0.0 Zhejiang Dahua Vision Technology Co., LTD Welcome Thank you for purchasing our Network camera! This user s manual is designed

More information

System Monitoring Library Windows Driver Software for Industrial Controllers

System Monitoring Library Windows Driver Software for Industrial Controllers IFPMGR.WIN System Monitoring Library Windows Driver Software for Industrial ontrollers Help for Windows www.interface.co.jp ontents hapter 1 Introduction...4 1.1 Overview... 4 1.2 Features... 4 hapter

More information

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2 CK3W Power Supply Unit CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2 Supplies power to the CK3M Controller CK3W-PD048 Features 24 VDC input The power supply status indicator shows operating status 1 Ordering

More information

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens). Vision OPLC Installation Guide Models V230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens). General Description Vision OPLCs

More information

The I-7530A RS-232/485/422 to CAN Converter

The I-7530A RS-232/485/422 to CAN Converter The I-7530A RS-232/485/422 to CAN Converter User s Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery

More information